Design , Supplying , Installation , Testing , Commissioning And Comprehensive Maintenance For Five Years Of 735 Kwp Dc Grid Connected Solar Photo Voltaic System At Cusat , Cochin, CUSAT, Kalamassery-Kerala

Roads And Bridges Development Corporation Of Kerala Limited has published Design , Supplying , Installation , Testing , Commissioning And Comprehensive Maintenance For Five Years Of 735 Kwp Dc Grid Connected Solar Photo Voltaic System At Cusat , Cochin. Submission Date for this Tender is 22-06-2020. Solar Power Plants Tenders in CUSAT, Kalamassery Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

24034458
Corrigendum : Design , Supplying , Installation , Testing , Commissioning And Comprehensive Maintenance For Five Years Of 735 Kwp Dc Grid Connected Solar Photo Voltaic System At Cusat , Cochin
Open Tender
Indian
Kerala
CUSAT, Kalamassery
22-06-2020

Tender Details

Design , Supplying , Installation , Testing , Commissioning And Comprehensive Maintenance For Five Years Of 735 Kwp Dc Grid Connected Solar Photo Voltaic System At Cusat , Cochin

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Mar-2020 Corrigendum I Date 21-04-2020
2 17-Apr-2020 Date Corrigendum Date 11-05-2020
3 07-May-2020 Date Corrigendum 3 Date 30-05-2020
4 29-May-2020 Date Corrigendum 4 Date 22-06-2020

Key Value

Document Fees
INR 8850 /-
EMD
INR 100000.0 /-
Tender Value
INR 3.62 Crore /-

BOQ Items

Name of Work:
Sl. No. Item Description Item Code / Make Quantity Units
1 0 PART A BI01010001010000000000000515BI0100001112
2 1 PART-A, HT EQUIPMENTS, 315 KVA 11kV Packaged Substation\nDesign, fabrication, supply, installation, testing and commissioning of outdoor type Packaged (Unitized) Substation enclosure with Ring Main Unit as per KSEB Norms and, 315 kVA,11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works for RCC foundation etc. complete as per single line diagram & technical specification.\nHT Compartment -11kV, 630A,21 KA for 3 seconds, 3Phase, 50Hz, SF6 insulated RMU comprising of 2 Nos Load Break Switch and one No. Vacuum Circuit breaker module with vaccum circuit breaker , three position isolator / earthing switch, bus bars, interlocking earth bar and stored spring energy mechanism.\n630 Amp continously rated Cu busbar\nSelf powered microprocessor based three over current and one earthfault relay with protection CT's - 1 set\nBattery and battery charger - 1 set\nProvision for padlocking for open, close, earth and test position\nTransformer Compartment - 315 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation,distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 500/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel.\nLT Chamber -500 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos.\nDin type HRC fuse unit, neutral link etc. -\n1No., 4A, C curve SP MCB - 3 nos., RYB indication lamp, LED type - 3 nos, (0-500)V voltmeter, Acc. class 1 with 90\ndeg defl. scale - 1 no., (0-500)A ammeter Acc. class 1 with 90, deg defl. scale - 3 nos, 6A 3 pole voltmeter selector switch - 1 no., 500/5A 5VA class 1 resin cast CT - 1 set, 500A TPN busbar chamber with Aluminium busbar.\nOutgoing- 100 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 5nos. and 63 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 2nos. BI01010001010000000000000515BI0100001113 1 no
3 2 315 KVA 11kV Packaged Substation - Design, fabrication, supply, installation, testing and commissioning of outdoor type Packaged (Unitized) Substation enclosure with Ring Main Unit as per KSEB Norms and, 315 kVA,11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works for RCC foundation etc. complete as per single line diagram & technical specification.\nHT Compartment - 11kV, 630A,21 KA for 3 seconds, 3Phase, 50Hz, SF6 insulated RMU comprising of 2 Nos Load Break Switch and one No. Vacuum Circuit breaker module with vaccum circuit breaker , three position isolator / earthing switch, bus bars, interlocking earth bar and stored spring energy mechanism\n630 Amp continously rated Cu busbar, Self powered microprocessor based three over current and one earthfault relay with protection CT's - 1 set, Battery and battery charger - 1 set, Provision for padlocking for open, close, earth and test position\nTransformer Compartment - 315 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation,distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 500/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel.\nLT Chamber - 500 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos. , Din type HRC fuse unit, neutral link etc. - ,1No. ,4A, C curve SP MCB - 3 nos. ,RYB indication lamp, LED type - 3 nos, (0-500)V voltmeter, Acc. class 1 with 90, deg defl. scale - 1 no., (0-500)A ammeter Acc. class 1 with 90\ndeg defl. scale - 3 nos, 6A 3 pole voltmeter selector switch - 1 no., 500/5A 5VA class 1 resin cast CT - 1 set\n500A TPN busbar chamber with Aluminium busbar.\nOutgoing - 100 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 4nos. and 40 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 3nos. BI01010001010000000000000515BI0100001114 1 no
4 3 315 KVA 11kV Packaged Substation - Design, fabrication, supply, installation, testing and commissioning of outdoor type Packaged (Unitized) Substation enclosure with Ring Main Unit as per KSEB Norms and, 315 kVA,11kV/433V 3 Ph, 50 Hz, vector Dyn -11, dry type, Transformer with IP23enclosure, winding temperature alarm and trip on transformer compartment and LV chamber suitable for termination of cable, complete with all standard fittings and accessories etc including necessary louvers and as per specifications attached in all respects as required. It shall includes all necessary control cabling for alarm, tripping & indication, all internal cabling as required. The rate shall be inclusive of all materials, lead, lift, necessary civil works for RCC foundation etc. complete as per single line diagram & technical specification.\nHT Compartment- 11kV, 630A,21 KA for 3 seconds, 3Phase, 50Hz, SF6 insulated RMU comprising of 2 Nos Load Break Switch and one No. Vacuum Circuit breaker module with vaccum circuit breaker , three position isolator / earthing switch, bus bars, interlocking earth bar and stored spring energy mechanism\n630 Amp continously rated Cu busbar, Self powered microprocessor based three over current and one earthfault relay with protection CT's - 1 set, Battery and battery charger - 1 set, Provision for padlocking for open, close, earth and test position\nTransformer Compartment - 315 kVA, 11kV/433V 3 Ph, 50Hz, dry type, vector Dyn -11 Transformer, copper wound, Class F insulation,distribution Transformer with forced ventilation. Losses shall be as per ECBC guidlines. The transformer shall have Delta on HV side and Star on LV side with off load tap changer range: + 5% to -10% in steps of 2.5%. The transformer shall have suitable enclosure for providing neutral CT of 500/5A 15VA 5P10 on earthed star point with connector for connection Earth Fault relay in HT/LT panel.\nLT Chamber - 500 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 1nos., Din type HRC fuse unit, neutral link etc. -1No., 4A, C curve SP MCB - 3 nos., RYB indication lamp, LED type - 3 nos, (0-500)V voltmeter, Acc. class 1 with 90, deg defl. scale - 1 no., (0-500)A ammeter Acc. class 1 with 90\ndeg defl. scale - 3 nos, 6A 3 pole voltmeter selector switch - 1 no., 500/5A 5VA class 1 resin cast CT - 1 set\n500A TPN busbar chamber with Aluminium busbar. Outgoing- 100 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 4nos. and 63 A FP Moulded Case Circuit Breaker with thermal release and neutral link (Ics =100%Icu= 25KA).- 5nos. BI01010001010000000000000515BI0100001115 1 no
5 4 PART - B, SOLAR PANELS & INVERTERS WITH DC COMPONENT, SOLAR PHOTO VOLTAIC PANELS\nSupply, installation testing and commissioning of solar photovoltaic modules meeting IEC 61215 (revised) / IS 14286 / IEC 61646standards & IEC 61730-1 with minimum efficiency of 17% with all accessories as per the tender specifiation - 735 KWp (DC) BI01010001010000000000000515BI0100001116 1 no
6 5 SOLAR STRING INVERTERS - Supply , Installation, Testing and Commissioning of following sized IP 65 rated out door three phase input, three Phase output, true sinewave inverter system, with Maximum Power Point Tracker charge controller and data logger system with minimum 180 dyas storage facility. The data shall have health status of individual strings. Minimum protection required shall be Over voltage/surge, over load, short circuit and anti- islanding protection. Earthing shall be provided as per IEC standards. IGBT based true sine wave output, Power factor corrected from end shall be min 0.95, Accuracy of AC voltage control = +/-3%, Accuracy of AC frequency control = +/-1%, Frequency = 50Hz, Intelligent interface with LED/LCD display, No-load losses less than 2%, Total Harmonic Distortion <3% BI01010001010000000000000515BI0100001117
7 5.01 680kVA, 400v, 50Hz, solar string inverters BI01010001010000000000000515BI0100001118 1 no
8 6 SUPPORTING STRUCTURES WITH FOUNDATION\nMounting structures for solar panels with Hot dip galvanized GI rectangular Tubes/Aluminium including 300*300*300mm concrete foundation. (for each panle) BI01010001010000000000000515BI0100001121 2297 no
9 7 DC Cabling and Accessories\nSingle core 4 Sq. mm Unarmoured copper Solar cables from Modules to String Combiner / Monitoring Box/inverter BI01010001010000000000000515BI0100001122 5742.5 m
10 8 UV Resistive MC4 Connectors suitable for terminating 4 Sq. mm copper cables(Male & Female Connectors) BI01010001010000000000000515BI0100001123 1250 no
11 9 UV Resistive MC4 Connectors suitable for terminating10 Sq. mm copper cables(Male & Female Connectors) BI01010001010000000000000515BI0100001124 150 no
12 10 1.5 inch cross section for routing 4 Sq. mm cables between Modules and Module to cable trays, including all accessories BI01010001010000000000000515BI0100001125 8150 m
13 11 150 mm Width, 75 mm Depth, 2 mm thick GI Prefabricated, Perforated cable trays BI01010001010000000000000515BI0100001126 450 m
14 12 DATA LOGGER AND MONITORING SYSTEM\nData logging and monitoring system with realtime data (wind, panel temperature, irradiance, power generation data from each string) available at central server and accesibility over internet. BI01010001010000000000000515BI0100001127 18 no
15 13 PART - C, AC CABLES AND CABLING\nSupply of following sizes of XLPE insulated PVC sheathed, Aluminium conductor armoured power cable of 11 KV grade conforming to IS 7098 amended upto date.\n3C X 150sq.mm. BI01010001010000000000000515BI0100001128 1687 m
16 14 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.\nAbove 120 sq. mm and upto 400 sq. mm BI01010001010000000000000515BI0100001129 1616 m
17 15 Laying of one no. PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in recess/ surface/ cable tray/ wall with saddles, clamps and all other accessories as required \nAbove 120 sq. mm and upto 400 sq. mm BI01010001010000000000000515BI0100001130 55 m
18 16 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required\n3C X150 sq.mm. BI01010001010000000000000515BI0100001131 6 set
19 17 Supplying and making straight through cable jointing with cast resin compound, including ferrule and other jointing materials, for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.\n3C X150sq.mm. BI01010001010000000000000515BI0100001132 4 set
20 18 Supply of following size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date. BI01010001010000000000000515BI0100001133
21 18.01 3.5C 185 Sq.mm Al BI01010001010000000000000515BI0100001134 680 m
22 18.02 3.5C 70 Sq.mm Al BI01010001010000000000000515BI0100001135 1110 m
23 18.03 3.5C 50Sq.mm Al BI01010001010000000000000515BI0100001136 390 m
24 18.04 3.5C 25 Sq.mm Al BI01010001010000000000000515BI0100001137 786 m
25 18.05 4C 16 Sq.mm Al BI01010001010000000000000515BI0100001138 40 m
26 18.06 4C 10 Sq.mm Al BI01010001010000000000000515BI0100001139 30 m
27 19 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. BI01010001010000000000000515BI0100001140
28 19.01 3.5C 185 Sq.mm Al BI01010001010000000000000515BI0100001141 2 no
29 19.02 3.5C 70 Sq.mm Al BI01010001010000000000000515BI0100001142 6 no
30 19.03 3.5C 50 Sq.mm Al BI01010001010000000000000515BI0100001143 4 no
31 19.04 3.5C 25 Sq.mm Al BI01010001010000000000000515BI0100001144 6 no
32 19.05 4C 16 Sq.mm Al BI01010001010000000000000515BI0100001145 2 no
33 19.06 4C 10 Sq.mm Al BI01010001010000000000000515BI0100001146 2 no
34 20 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall or surface as required. BI01010001010000000000000515BI0100001147
35 20.01 Upto 35 sq. mm (clamped with 1mm thick saddle) BI01010001010000000000000515BI0100001148 135 m
36 20.02 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) BI01010001010000000000000515BI0100001149 150 m
37 20.03 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) BI01010001010000000000000515BI0100001150 40 m
38 21 Laying of one number PVC insulated and PVC sheathed armoured power cable of 1.1kV grade fo the following sizes in ground including excavation ,sand cushioning , providing protective covering and refilling the trench etc. as required BI01010001010000000000000515BI0100001151
39 21.01 Upto 35 sq. mm BI01010001010000000000000515BI0100001152 721 m
40 21.02 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) BI01010001010000000000000515BI0100001153 1350 m
41 21.03 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) BI01010001010000000000000515BI0100001154 640 m
42 21.04 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. BI01010001010000000000000515BI0100001155 235 no
43 22 PART - D, EARTHING AND SAFETY EQUIPMENTS\nEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.\n BI01010001010000000000000515BI0100001156 14 no
44 22.01 Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required - 25mm X 6mm GI BI01010001010000000000000515BI0100001157 1500 m
45 22.02 Providing and fixing GI/Cu strip/wire on surface or in recess for connections etc. as required - 6 SWG Cu BI01010001010000000000000515BI0100001158 300 m
46 23 Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)\n25mm X 6mm GI BI01010001010000000000000515BI0100001159 500 m
47 23.01 Supplying and laying G.I/Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) - 6 SWG Cu BI01010001010000000000000515BI0100001160 100 m
48 24 PART- E, LIGHTNING PROTECTION - Supply and fixing of 8 mm Aluminum Round Conductor as horizontal air terminal for parapet wall/terrace with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3 BI01010001010000000000000515BI0100001161 750 m
49 25 Supply and fixing of 8 mm Aluminum Round Conductor as down conductor with the required mounting clamps , cross connectors , expansion piece and other accessories required as per IEC 62305-3 BI01010001010000000000000515BI0100001162 150 m
50 26 Providing and fixing of test joint suitable for hot dipped galvanized steel tape 30 mm x 3mm and 8mm dia solid round aluminium conductor made of stainless steel SS 304 grade. Conforms to the requirements according to (IS/IEC 62305).with an outdoor glass-fibre reinforced polycarbonate enclosure having minimum inner dimension of 75mm x 75 mm x 50 mm. BI01010001010000000000000515BI0100001163 16 set
51 27 Providing and laying hot dipped galvanized steel tape 30 mm X3 mm from earth electrode directly in ground as required. BI01010001010000000000000515BI0100001164 640 m
52 28 PART- F\nComprehensive AMC of the entire solar power plant for 5 years from the date of handing over to CUSAT. BI01010001010000000000000515BI0100001165 1 Set