Local Self Government Department has published Fresh Tender Alappuzha Jp_Plan 19-20_Supply And Installation Of Generator For Air Conditioning Jilla Panchayath Conference Hall Electrical Work. Submission Date for this Tender is 23-03-2020. Electric Generator Tenders in PLEASE REFER WORK ITEM DETAILS Kerala. Bidders can get complete Tender details and download the document.
Work Name:ALAPPUZHA JP_PLAN 19-20_SUPPLY AND INSTALLATION OF GENERATOR FOR AIR CONDITIONING JILLA PANCHAYATH CONFERENCE HALL | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | electrical | BI01010001010000000000000515BI0100001113 | ||
2 | 1.001 | 90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories). | BI01010001010000000000000515BI0100001114 | 1 | point |
3 | 1.002 | od529489/2019_2020 : Supply, conveyance installation testing and commissioning of pre-wired LED tube light fittings,Philips endura high efficiency BN 108 C 20S CDL white complete with replaceable driver unit and LEd assumbly housed in side the box type fitting with all accessories on wall /ceiling with PVC/TW round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire .<br> | BI01010001010000000000000515BI0100001115 | 1 | each |
4 | 1.003 | 90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required | BI01010001010000000000000515BI0100001116 | 25 | metre |
5 | 1.004 | 90.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required | BI01010001010000000000000515BI0100001117 | 5 | metre |
6 | 1.005 | 1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | BI01010001010000000000000515BI0100001118 | 25 | metre |
7 | 1.006 | 90.12.1.28 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil). | BI01010001010000000000000515BI0100001119 | 15 | metre |
8 | 1.007 | 90.12.6.41 : Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required. | BI01010001010000000000000515BI0100001120 | 35 | metre |
9 | 1.008 | 90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. | BI01010001010000000000000515BI0100001121 | 35 | metre |
10 | 1.009 | 9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 35 sq. mm (32mm) | BI01010001010000000000000515BI0100001122 | 6 | set |
11 | 1.01 | 9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm) | BI01010001010000000000000515BI0100001123 | 8 | set |
12 | 1.011 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch | BI01010001010000000000000515BI0100001124 | 1 | each |
13 | 1.012 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet | BI01010001010000000000000515BI0100001125 | 1 | each |
14 | 1.013 | 1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) | BI01010001010000000000000515BI0100001126 | 1 | each |
15 | 1.014 | 2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door | BI01010001010000000000000515BI0100001127 | 2 | each |
16 | 1.015 | 2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | BI01010001010000000000000515BI0100001128 | 2 | each |
17 | 1.016 | 2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps | BI01010001010000000000000515BI0100001129 | 2 | each |
18 | 1.017 | 5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. | BI01010001010000000000000515BI0100001130 | 3 | set |
19 | 1.018 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required | BI01010001010000000000000515BI0100001131 | 80 | metre |
20 | 1.019 | 90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required | BI01010001010000000000000515BI0100001132 | 50 | metre |
21 | 1.02 | 90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. | BI01010001010000000000000515BI0100001133 | 12 | each |
22 | 1.021 | 90.16.5.6 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required. | BI01010001010000000000000515BI0100001134 | 16 | each |
23 | 1.022 | 14.1 : Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. | BI01010001010000000000000515BI0100001135 | 5 | cum |
24 | 1.023 | 14.7 : Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. | BI01010001010000000000000515BI0100001136 | 2 | cum |
25 | 1.024 | 14.9 : Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required. | BI01010001010000000000000515BI0100001137 | 1 | cum |
26 | 1.025 | 14.12 : Providing 15mm thick cement plaster of mix 1:4 (1 cement : 4 fine sand) at all levels. | BI01010001010000000000000515BI0100001138 | 5 | sqm |
27 | 1.026 | od529074/2019_2020 : SCITC of 40 kVA Diesel Generator set complete with integral acoustic enclosure as per existing CPCB&lt;br&gt;norms with standard accessories and as per technical details given below 1. Engine a) Make of Engine -&lt;br&gt;Kirloskar/ Cummins/ Leyland/Volvo/Catterpiller b) Type of Engine - Diesel Engine c) No. of Cylinders- as&lt;br&gt;per manufacturer&apos;s standards. d) Method of Cooling &ndash; Liquid cooled with radiator. e) Aspiration -Turbo&lt;br&gt;charged, charge air cooled. f) Design - Suitable for generator set operation. g) Output- As per&lt;br&gt;manufacturer&apos;s standards. 2. Standard accessories with Diesel Engine. a) Fly wheel to suit flexible&lt;br&gt;coupling b) Close Coupling c) Air cleaner d) Radiator with fan provided with fan guard. e) Fuel Pump f)&lt;br&gt;Mechanical governor g) Fuel filter h) Exhaust silencer i) Exhaust Muffler j) Lubricating oil filter. k) Battery&lt;br&gt;Charger/Generator 3. Engine Instrument Panel with the following items a) Starting switch with key or&lt;br&gt;button. b) Lubricating oil pressure gauge. c) Water temperature gauge. d) RPM Indicator with hour meter.&lt;br&gt;e) Battery charging Ammeter. 4. Safety Controls for Engine. a) Trip for low lubricating oil pressure. b) Trip&lt;br&gt;for high water temperature. 5.Fuel pipe: Oil resistance flexible hoses of 20mm dia or nearest size MS&lt;br&gt;pipe as per manufacturer&apos;s standard, 6 Brush less Alternator a) Make - Stamford/Kirloskar/crompton/KEL&lt;br&gt;b) Type - Self exited and self-regulated, brush less c) Capacity &ndash; 40kVA/ 32 K W @ 0.8PF d) System of&lt;br&gt;Voltage - 3 phase, 415 V, 4 wire system. e) Speed - 1500 rpm f) Voltage regulation band - +/-2.5% of&lt;br&gt;rated voltage g) Frequency - 50 Hz h) Insulation - Class -F/H .The Alternator should confirm to IS 4722.&lt;br&gt;Operation and service manual, spares and tools shall be provided. . 7.Fuel Tank of suitable size built in&lt;br&gt;type integrated with the acoustic enclosure. Fuel connection shall be done as per standards.7. Battery-&lt;br&gt;Suitable size built in type integrated battery with leads and terminals of appropriate AH capacity as per&lt;br&gt;Manufacturer&apos;s requirement. 8. Automatic Battery charger. Push button switch for ON/OFF - 1 set.&lt;br&gt;Metallic DNB - 1No Solid state phase indication lamp for supply ON/OFF with HRC protection Supply of&lt;br&gt;HSD of half tank capacity for test run, The standard Electric control panel integrated with acoustic&lt;br&gt;enclosure comprising of the following. a) 63A, 25/35KA, 4Pole MCCB having adjustable setting, b) Digital&lt;br&gt;Multi function meter with accuracy class 1 to read parameters such as KW, KVA, PF, voltage, Current&lt;br&gt;Frequency etc: c) Digital type single function KWH meter with accuracy class 1, d) LED type phase&lt;br&gt;indication Lamp for indicating the presence of supply on all phases,&lt;br&gt;10.Exhaust Piping .Exhaust&lt;br&gt;Piping shall be vent to the top of the nearest tallest building if required . If the pipe cannot be&lt;br&gt;clamped/fixed to the building or any other structure of permanent nature necessary fabricated structures&lt;br&gt;using channel section or angle iron sections of adequate mechanical strength, duly painted with 2 coats&lt;br&gt;of Heat retardant aluminium paint shall be provided for the support of the exhaust pipe. (Additional piping&lt;br&gt;will be measured excluding the standard length of pipe supplied by the manufacturer.) | BI01010001010000000000000515BI0100001139 | 1 | each |
28 | 1.027 | od529075/2019_2020 : Supply & laying /clamping 25x3mm GI strip in position as required. | BI01010001010000000000000515BI0100001140 | 40 | metre |
29 | 1.028 | od529076/2019_2020 : Aluminium anodised Danger Notice Board of size 150 x 100 mm. with inscriptions ( both in English and Malayalam) and conventional Skull and Bone in Red colour.<br> | BI01010001010000000000000515BI0100001141 | 2 | each |
30 | 1.029 | od529077/2019_2020 : Charges for preparing schematic diagrams for initial & final approval for submitting Electrical inspectorate | BI01010001010000000000000515BI0100001142 | 1 | set |
31 | 1.03 | od529078/2019_2020 : Charges for remitting required amount of inspection fee ,initial & final approval charges to Electrical inspectorate. Actual amount reimbursed producing original bills | BI01010001010000000000000515BI0100001143 | 1 | L.S |
32 | 1.031 | od529079/2019_2020 : Painting letters or figures of the following sizes with enamel paint as identification mark to SB, DB, panel board etc as required.2.5 x 4 CM <br> | BI01010001010000000000000515BI0100001144 | 150 | each |
33 | 1.032 | od529080/2019_2020 : Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.<br> | BI01010001010000000000000515BI0100001145 | 1 | each |
34 | 1.033 | od529081/2019_2020 : Supply and providing 2mm thick Elastomeric fire retardent insulating mat as per IS 15652/2006 to withstand 3.3 KV dielectric strength. <br> | BI01010001010000000000000515BI0100001146 | 6 | per sqm |
35 | 1.034 | od529082/2019_2020 : Supply and providing extra length of heavy duty MS pipe 65mm dia./ nearest size with suitable angle iron support as required. | BI01010001010000000000000515BI0100001147 | 15 | per metre |
36 | 1.035 | od529083/2019_2020 : Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint 'FIRE' mounted on MS angle frame work/ wall bracket filled with fine sand, painting the bracket/ floor stand including making good the damages, colour washing etc. as required.<br> | BI01010001010000000000000515BI0100001148 | 6 | each |
37 | 1.036 | od529084/2019_2020 : Supplying and installation of supports, anchor bolts etc made out of suitable size single section MS angle, flats etc as required including painting with 2 coats of synthetic enamel paint<br> | BI01010001010000000000000515BI0100001149 | 25 | kg |
38 | 1.037 | od529085/2019_2020 : Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel <br> | BI01010001010000000000000515BI0100001150 | 70 | kg |
39 | 1.038 | od529088/2019_2020 : Supplying, laying and jointing of 40/32 mmm dia. /nearest size of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories clamping in position. | BI01010001010000000000000515BI0100001151 | 20 | metre |
40 | 1.039 | od529089/2019_2020 : SUPPLY AND FIXING OF FIRE EXTINGUISHER CO2 4.5 KG AS PER IS 15683 WITH ISI MARK | BI01010001010000000000000515BI0100001152 | 3 | each |
41 | 1.04 | od529090/2019_2020 : Charges for preparing CL sketch and application for KSEB service connection for 3 phase | BI01010001010000000000000515BI0100001153 | 1 | each |
42 | 1.041 | od529091/2019_2020 : Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 12 x 3 mm, 25 x 3 mm brass bolt & nut | BI01010001010000000000000515BI0100001154 | 30 | each |
43 | 1.042 | od529498/2019_2020 : Supply & providing Battery charger (extra) fitted in position as required. | BI01010001010000000000000515BI0100001155 | 1 | each |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy