Nit-57 Repair/ Maintenance To Transformer , Voltage Stablizer , Street Light , Dg Set And Other Connected Items At Rakhmuthi Under Ge ( South ) Akhnoor ., RAKHMUTHI PALLANWALA AREA-Jammu And Kashmir

Military Engineer Services-MES has published Nit-57 Repair/ Maintenance To Transformer , Voltage Stablizer , Street Light , Dg Set And Other Connected Items At Rakhmuthi Under Ge ( South ) Akhnoor .. Submission Date for this Tender is 28-03-2020. Electrical Maintenance Tenders in RAKHMUTHI PALLANWALA AREA Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

24029377
Nit-57 Repair/ Maintenance To Transformer , Voltage Stablizer , Street Light , Dg Set And Other Connected Items At Rakhmuthi Under Ge ( South ) Akhnoor .
Open Tender
Indian
Jammu And Kashmir
RAKHMUTHI PALLANWALA AREA
28-03-2020

Tender Details

Nit-57 Repair / Maintenance To Transformer , Voltage Stablizer , Street Light , Dg Set And Other Connected Items At Rakhmuthi Under Ge ( South ) Akhnoor . - 2 Disconnecting Electrical Connections From Ht And Lt Sides Of Old Serviceable / Damaged / Burnt Step Down Transformers Of Any Descriptions, Capacity Exceeding 25 Kva But Not Exceeding 100 Kva, Any Type And Taking Down From The Platforms Or Mounted On Exisiting Position ( Four Poles / Two Pole Structure ) By Hydraulic Cranes Of Suitable Capacity And Transporting By Truck / Lorry To The Workshop, Opening Top Cover, Draining Out The Transformer Oil In Clean Barrels, Cleaning Of Sludge From Oil Tank And Conservator Tank, Cleaning And Polishing Of Tapping Contact Point, Opening Carefully Copper Wire / Strip Wound Lt Coils And Rewinding The Same After Providing New Necessary Insulating Packing Material By Using The Same Old Strip / Wire, Refitting Top Cover With Replacement Of Studs, Nuts, Bolts, Washers And Gasket After Repairs / Replacement Of Unserviceable Parts And Cleaning The Transformer And Making The Transformer Absolutely Leak Proof, Pouring In The Insulating Oil In The Transformer, Placing In Original Position On Four Pole / Two Pole Structure / Platform At Site And Making All Ht / Lt Connections Including Testing The Transformer After Necessary Repairs, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Spares Required For Repair / Replacement Of Unserviceable Parts Shall Be Measured And Paid Separately Under Relevant Items Of Boq. 3 Description All As Serial Item No- 2.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 160 Kva. 4 Description All As Serial Item No- 2.00 Here-In-Before But For Transformer Of Capacity Exceeding 160 Kva But Not Exceeding 250 Kva. 5 Description All As Serial Item No- 2.00 Here-In-Before But For Transformer Of Capacity Exceeding 250 Kva But Not Exceeding 400 Kva. 6 Supply And Fixing In Replacement Of Ht Coil Of Transformer Capacity 25 Kva To 400 Kva, Made Of Super Enameled Copper Winding Wire / Strip Of Existing Insulation, Gauge And Specifications, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Ht Coil Shall Have Same Number Of Turns Of Winding Wire And With Matching To Manufacturer Design. Nmake: Atlas / Htp / Bic. 7 Supply And Fixing In Replacement Of Lt Coil Of Transformer Capacity 25 Kva To 400 Kva, Made Of Super Enameled Copper Winding Wire / Strip Of Existing Insulation, Gauge And Specifications, Complete All As Specified And As Directed. Nnote: Lt Coil Shall Have Same Number Of Turns Of Winding Wire And With Matching To Manufacturer Design. Nmake: Atlas / Htp / Bic. 8 Replacement Of Old Unserviceable / Damaged Ht Bushing Assembly With New Ht Bushing Assembly ( Set Of Three ) With Insulated Brass Stud Including Nuts, Bolts And Washers, Suitable For Transformer Of Any Type, Capacity 25 Kva To 100 Kva, Complete All As Specified And As Directed. 9 Description All As Serial Item No- 8.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 10 Description All As Serial Item No- 8.00 Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 11 Replacement Of Old Unserviceable / Damaged Lt Bushing Assembly With New Lt Bushing Assembly ( Set Of Four ) With Insulated Brass Stud Including Nuts, Bolts And Washers, Suitable For Transformer Of Any Type, Capacity 25 Kva To 100 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 12 Description All As Serial Item No- 11.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 13 Description All As Serial Item No- 11.00 Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 14 Replacement Of Old Unserviceable / Damaged Temperature Gauge With New Temperature Gauge, Suitable For Transformer Of Any Type, Capacity 25 Kva To 100 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 15 Description All As Serial Item No- 14.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 16 Description All As Serial Item No- 14.00 Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 17 Replacement Of Old Unserviceable / Damaged Tap Changing Assembly With New Tap Changing Assembly, Off Load, On Ht Winding To Vary The Voltage ±7.5%, In Steps Of 2.50%, Including Necessary Connection, Ht Winding, Re-Insulation For Complete Functioning Of Tap Changer, Transformer Capacity 25 Kva To 100 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 18 Description All As Serial Item No- 17.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 19 Description All As Serial Item No- 17.00Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 20 Dehydration And Filtration Of Transformer Oil After Draining Out Oil From Transformer By The Dehydration Machine At Site Or Nearby Transformer Workshop To Achieve Di-Electric Strength 40 Kv At 4Mm Gap, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: N ( I ) Cost Of Transportation Of Dehydration Machine And Other Required Materials And Tools, Plants Shall Be Deemed To Be Included In The Quoted Rates. N ( Ii ) Test Certificate Of Di-Electric Strength Shall Be Produce Before And After Dehydradation And Filtration Process. 21 Replacement Of Old Unserviceable / Damaged Air Breather Assembly With New Air Breather Assembly With Silica Gel Suitable For 11 / 0.433 Kv Transformer Including Nuts, Bolts And Washers, Suitable For Transformer 25 Kva To 100 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 22 Description All As Serial Item No- 21.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 23 Description All As Serial Item No- 21.00 Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 24 Supply Only Fresh Transformer Oil To Top-Up And Filling In The Existing Transformer, Di-Electric Strength Not Than 45 Kv, Meeting Bureau Of Indian Standards: Is 335-1993 ( Reaffirmed-2005 ) Specification, Examined In A 100Mm Thick Layer At 270°C, Clear, Transparent And Free From All Type Of Suspended Matter Or Sediment, Complete All As Specified And As Directed By Engineer-In-Charge. Nmake: Iocl / Hpcl / Bpcl / Reliance. 25 Preparation Of Old, External Surface Of Transformers Capacity 25 Kva To 100 Kva, By Removing The Scrap, Rust, Washing Including Cleaning And Spray Painting With Two Coats Of Synthetic Enamel Paint Including Numbering Mes No In White Colour Synthetic Enamel Paint, At Site Or At Workshop, Complete All As Specified And As Directed By Engineer-In-Charge. 26 Description All As Serial Item No- 25.00 Here-In-Before But For Transformer Of Capacity Exceeding 100 Kva But Not Exceeding 200 Kva Capacity. 27 Description All As Serial Item No- 25.00 Here-In-Before But For Transformer Of Capacity Exceeding 200 Kva But Not Exceeding 400 Kva Capacity. 28 Disconnecting Electric Connections Of Servo Voltage Stabilizers, Capacity 15 Kva To 30 Kva, Draining Out The Transformer Oil In Clean Barrels For Re-Use, Cleaning Of Sludge From Oil Tank And Transporting To Workshop For Repairs And Return Back To Its Original Position After Repairs Including Loading And Unloading By Mechenical Means, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Spares Required For Repair / Replacement Of Unserviceable Parts Shall Be Measured And Paid Separately Under Relevant Items Of Boq. 29 Description All As Serial Item No- 28.00 Here-In-Before But For Servo Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 30 Description All As Serial Item No- 28.00 Here-In-Before But For Servo Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 31 Replacement Of Old Unserviceable Printed Circuit Board ( Pcb ) With New Printed Circuit Board ( Pcb ) Of Voltage Stabilizer As Per Existing Make And Type, Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 32 Description All As Serial Item No- 31.00 Here-In-Before But For Servo Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 33 Description All As Serial Item No- 31.00 Here-In-Before But Forservo Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 34 Replacement Of Old Unserviceable Carbon Bushes With New Carbon Bushes Of Voltage Stabilizer As Per Existing Make And Type, Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 35 Description All As Serial Item No- 34.00 Here-In-Before But For Servo Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 36 Description All As Serial Item No- 34.00 Here-In-Before But For Servo Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 37 Replacement Of Old Unserviceable Servo Motor With New Servo Motor Of Voltage Stabilizer As Per Existing Make And Type, Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 38 Description All As Serial Item No- 37.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 39 Description All As Serial Item No- 37.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 40 Digital Voltmeter, Range 0-500 Volts, Size 96Mmx96mm, Flush Type, Complete All As Specified And As Directed By Engineer-In-Charge. 41 Digital Ammeter, Range 0-100 Amps, Size 96Mmx96mm, Square Shape, Complete All As Specified And As Directed By Engineer-In-Charge. 42 Selector Switch Suitable For Voltmeter / Ammeter As Per Existing Design And Range, Complete All As Specified And As Directed By Engineer-In-Charge. 43 Replacement Of Old Unserviceable Servo Dimmer Booster Coil With New Servo Dimmer Booster Coil, For Automatic Voltage Corrections, Make, Type And Design As Per Site Requirement, Suitable For Voltage Stabilizer Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 44 Description All As Serial Item No- 43.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 45 Description All As Serial Item No- 43.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 46 Replacement Of Old Unserviceable Control Wiring With New Control Wiring Of Voltage Stabilizer As Per Existing Make And Type, Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 47 Description All As Serial Item No- 46.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 100 Kva Capacity. 48 Description All As Serial Item No- 46.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 100 Kva But Not Exceeding 250 Kva Capacity. 49 Supply And Fixing In Replacement / Re-Winding Of Transformer Coil Of Voltage Stabilizer Of Capacity 25 Kva To 400 Kva, Made Of Super Enameled Copper Winding Wire / Strip Of Existing Insulation, Gauge And Specifications, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Transformer Coil Shall Have Same Number Of Turns Of Winding Wire And With Matching To Manufacturer Design. Nmake: Atlas / Htp / Bic. 50 Replacement Of Old Unserviceable Dimmer Gear Set With New Cast Iron Dimmer Gear Set, For Automatic Voltage Corrections, Make, Type And Design As Per Site Requirement, Suitable For Voltage Stabilizer Capacity 15 Kva To 30 Kva, Complete All As Specified And As Directed By Engineer-In-Charge. 51 Description All As Serial Item No- 50.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 30 Kva But Not Exceeding 60 Kva Capacity. 52 Description All As Serial Item No- 50.00 Here-In-Before But For Voltage Stabilizer Of Capacity Exceeding 60 Kva But Not Exceeding 100 Kva Capacity. 53 Construction Of Fire Point Having A Platform As Per Standard Design / Size And Height, Constructed In Brick Work In 1:4 Cement Mortar, And Rendering 15Mm Thick On Brick Masonry Surfaces In 1:4, Plain Cement Concrete Flooring With Pcc As Per Zonal Specifications, Including Roof Covering In Hut Shape With 0.80Mm Thick Plain Galvanised Iron Sheet With Angle Iron 50X50x6mm And Flat Iron 40X60mm, Fire Point Shall Be Painted In Red Colour Synthetic Enamel Paint After Preparation Of Surfaces Having Fire Point Word On Top Of Roof Covering In White Colour Synthetic Enamel Paint, Complete All As Specified. Nnote: Cost Of Following Equipments / Accessories Shall Also Be Deemed Inclusive In Quoted Rate: N ( A ) 03 Nos. Of Fire Extinguishers, Discharge Carbon-Di-Oxide Type, Having 140Kg / Sqcm Working Pressure, Isi Marked 6.50 Kg Capacity With Hose Pipe, Conforming To Is-2873, Complete In All Respect To Working In Any Emergency Situation And Temperature Between -30 To +55 Degree Centigrade. N ( B ) Fire Bucket Duly Paint In Red Colour And Filling With Fine Sand- 02 Nos. N ( C ) Fire Beater Duly Painted In Red Colour- 02 Nos. N ( D ) Shovel With Long Handle Duly Painted In Red Colour- 02 Nos. N ( E ) Fire Hook Duly Painted In Red Colour- 02 Nos. 54 Broken Stone Aggregate For Loose Filling In The Area Sarroundings Of Transformer, Of Gauge 20 Mm To 40 Mm Graded, Laying In Layers Thickness Not Exceeding 150Mm, Complete All As Specified And As Directed By Engineer-In-Charge. 55 Replacement Of Old Unserviceable Rubber Mat With New Synthetic Rubber Insulating Mat For Preventing Ht Shock, Thickness Not Less Than 25Mm, Size 2.00X1.00 Mtrs, Complete All As Specified And As Directed By Engineer-In-Charge. 56 Display Board, Size 1.50X1.20X0.30 Mtrs, And Cubical Type, Made Of 3.0Mm Thick Acrylic Sheet ( Transparent Type ) Of Superior Quality Having Installation Details In Approved Colour Letters Atleast 12Mm Wide And 100Mm High, Cubical Shall Be Fixed On Painted Angle Iron Frame Of Size 40X40x6mm, 1500Mm High From Ground Level, Embedded In Pcc 1:2:4 Below 450Mm From Ground Level, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Colour Of Letters Shall Be As Approved By Engineer-In-Charge. 57 Led Street Light Made Up Of Pressure Die Cast Aluminium Housing With High Power Led As Lighting Source And Lens Embedded Pc Cover Having Top Opening Seperate Driver Compartment With Ip66 Protection, Including Led Lamps Of 45 Watt And Connecting Up With Twin Core Twisted Flexible Copper Conductor Cable Of Suitable Size, Complete All As Specified. Nmake: Havells Cat Part No- Endura Pearl Neo Sl45wled757sasytopc / Philips Ordering Code No- 910925866055 ( Product Code- 871869634894900 ) / Bajaj Ordering Code No- 169799 ( Product Code- Brtfg 45W Led I ) . 58 Replacement Of Old Unserviceable / Damaged Cable Jointing Kit With New Cable Jointing Kit For Cable Jointing Kit For 11 Kv ( Earthed ) Grade Cable For Outdoor Termination Heat Shrink Type Joint Complete With Jointing Material And Accessories Suitable For Xlpe Armoured Aluminium Conductor Cable Of Size 50 Sqmm To 95 Sqmm, 3.0-Core, Complete All As Specified And As Directed By Engineer-In-Charge. 59 Supply, Testing And Commissioning In-Replacement Of Air Break Switch With Drop Out Fuse Set 12 Insulators, Gang Operated For 11000 Volts, Triple Pole, Mechanically Operated, Vertical Mounted On Insulator And Steel Frame, With Operating Mechanism And Galvanised Iron Operating Rod, Worked From Ground Level, Consisting Ht Insulators As Per Iss / Bss, Non Ferrous Knife And Spring Loaded Contacts, Arcing Horns Of Adequate Section To Break Magnetising Current Of Tf’S For Current Rating Upto 200 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 60 Replacement Of Old Unserviceable Lightning Arresters With New Lightning Arresters Expulsion Type Complete With All Fittings, Transmission Class, Discharge Capacity 65 Kilo Amp, Suitable For 11000 Volts, Complete All As Specified And As Directed By Engineer-In-Charge. 61 Earthing Complete With Galvanised Iron Earth Plate Electrode 600X600x6mm Buried Directly In Ground ( Earth Pit Not Less Than 2.25Mtr Deep Below Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5Mtr Below Normal Ground Level, Connected With Galvanised Iron Strip, Size 32X6mm As Earth Lead, By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel Complete With 40Mm Dia Gi Light Grade Protection Pipe, 20Mm Dia Gi Medium Grade Watering Pipe With Funnel Including Charcoal, Dust, Salt, Pcc M-15, Type B-1 In Pit With Precast Rcc M-15 ( 1:2:4 ) , Type B-1 ( Using 20Mm Graded Crushed Stone Aggregates ) In Cover Reinforced With Xpm Not Less Than 4.0 Kg Per Sqm, Test Point Etc. All As Shown In Electric Plate No-3 Of Ssr Part-I ( 2009 ) , Complete With Necessary Earth Work In Any Type Of Soil, Removal To A Distance Not Exceeding 50Mtr, Including Testing On Completion, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Nearth Pit Chamber And Rcc Pit Cover Shall Be Painted With Two Coats Of Red Synthetic Enamel Paint Over One Coat Of Primer Including Preparing Of Surfaces. N 62 Taking Down Existing Unserviceable / Rusted Structural Steel In Cross Arms, Complete All As Specified And As Directed By Engineer-In-Charge. 63 Mild Steel In Cross Arms, Bracings, Supports, Clamps And Back Plates Fabricated From Structural Steel Sections Including Nuts, Bolts, Washers, Welding, Bending Cold Or Hot, Drilling Holes For Bolts, In Any Shape Or Size As Indicated Or Directed And Inclusive Of One Coat Of Red Oxide Primer, One Under Coat And One Finishing Coat Of Aluminium Paint, Complete All As Specified And As Directed By Engineer-In-Charge. 64 Description All As Serial Item No- 63.00 Here-In-Before But Except New Cross Arms Of Mild Steel. Nnote: Quotyed Rate Shall Be Deemed Inclusive Inclusive Of One Coat Of Red Oxide Primer, One Under Coat And One Finishing Coat Of Aluminium Paint. 65 Replacement Of Old Unserviceable / Damaged Mccb With New Mccb, Four Pole, 415 Volts, Adjustable Thermal And Adjustable Magnetic Setting, 200 Amps With Breaking Capacity 36 Ka, Having Indicating Lamp, Ics=100% Icu As Per Iec 60947-2, Complete All As Specified And As Directed By Engineer-In-Charge. Nmake: Abb Cat Part No- 1Sda068109r1 Or Equivalent In L&T / Merlin Gerin / Siemens. 66 Replacement Of Old Unserviceable / Damaged Mccb With New Mccb, Four Pole, 415 Volts, Adjustable Thermal And Fixed Magnetic Setting, 100 Amps With Breaking Capacity 16 Ka, Having Indicating Lamp, Ics=100% And Icu As Per Iec 60947-2, Complete All As Specified And As Directed By Engineer-In-Charge. Nmake: Abb Cat Part No- 1Sda067039r1 Equivalent In L&T / Legrand / Merlin Gerin / Siemens. 67 Replacement Of Old Unserviceable / Damaged Mccb With New Mccb, Four Pole, 415 Volts, Adjustable Thermal And Fixed Magnetic Setting, 63 Amps With Breaking Capacity 16 Ka, Having Indicating Lamp, Ics=100% And Icu As Per Iec 60947-2, Complete All As Specified And As Directed By Engineer-In-Charge. Nmake: Abb Cat Part No- 1Sda067037r1 Or Equivalent In L&T / Legrand / Merlin Gerin / Siemens. 68 Earthing Complete With Copper Earth Plate Electrode 600X600x6mm Buried Directly In Ground ( Earth Pit Not Less Than 2.25Mtr Deep Below Ground Level ) With Top Edge Of Earth Plate Not Less Than 1.5Mtr Below Normal Ground Level, Connected With Copper Strip, Size 20X3mm As Earth Lead, By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Complete With 40Mm Dia Gi Light Grade Protection Pipe, 20Mm Dia Gi Medium Grade Watering Pipe With Funnel Including Charcoal, Dust, Salt, Pcc M-15, Type B-1 In Pit With Precast Rcc M-15 ( 1:2:4 ) , Type B-1 ( Using 20Mm Graded Crushed Stone Aggregates ) In Cover Reinforced With Xpm Not Less Than 4.0 Kg Per Sqm, Test Point Etc. All As Shown In Electric Plate No-3 Of Ssr Part-I ( 2009 ) , Complete With Necessary Earth Work In Any Type Of Soil, Removal To A Distance Not Exceeding 50Mtr, Including Testing On Completion, Complete All As Specified And As Directed By Engineer-In-Charge. Nnote: Nearth Pit Chamber And Rcc Pit Cover Shall Be Painted With Two Coats Of Red Synthetic Enamel Paint Over One Coat Of Primer Including Preparing Of Surfaces. N 69 Earth Continuity Conductor Or Main Earthing Lead Fixed To Wall On Batten Or Recess Or Chases Or Buried In Ground Or Drawn In Conduit / Pipe Or Fixed In Any Other Indicated Situation For Loop Earthing Etc. As Required, Copper Strip 20X3.0Mm With Saddles And Fixing, Complete All As Specified And As Directed. 70 Replacement Of Old Unserviceable / Damaged Industrial Cable With New Industrial Cable, Pvc Insulated, Round, Heavy Duty Electric Power Cable With Copper Conductor, 1100 Volts Grade, Cross-Sectional Area 2.50 Sqmm, 4.0-Core, Including Suitable Lugs And Accessories For Making Connections, Complete All As Specified And As Directed. 71 Replacement Of Old Unserviceable / Damaged Industrial Cable With New Industrial Cable, Pvc Insulated, Round, Heavy Duty Electric Power Cable With Copper Conductor, 1100 Volts Grade, Cross-Sectional Area 2.50 Sqmm, 8.0-Core, Including Suitable Lugs And Accessories For Making Connections, Complete All As Specified And As Directed. 72 Replacement Of Old Unserviceable / Damaged Industrial Cable With New Industrial Cable, Pvc Insulated, Round, Heavy Duty Electric Power Cable With Copper Conductor, 1100 Volts Grade, Cross-Sectional Area 4.0 Sqmm, 4.0-Core, Including Suitable Lugs And Accessories For Making Connections, Complete All As Specified And As Directed. 73 Replacement Of Old Unserviceable / Damaged Industrial Cable With New Industrial Cable, Pvc Insulated, Round, Heavy Duty Electric Power Cable With Copper Conductor, 1100 Volts Grade, Cross-Sectional Area 4.0 Sqmm, 8.0-Core, Including Suitable Lugs And Accessories For Making Connections, Complete All As Specified And As Directed. 74 Disconnecting All Electric Connections From Alternator And Fuel Connection From Engine, Decoupling Of Engine And Alternator, Of Diesel Driven Diesel Generator Of Capacity 20 To 30 Kva, For Servicing And Minor Repair, And Carrying Out The Servicing After De-Assembling The External Engine Assembly, Cleaning / Washing The Engine Outer Body And Oiling Other Movable Parts, Replacing Defective Spare Parts With New Spare Parts As Required For Smooth Functioning Of Diesel Engine To Avoid Any Break Down, Servicing At The Engine In Existing Position Complete And Testing On Completion, All As Specified And As Directed By Engineer-In-Charge. Nmake: Repaired At Site Shall Be Mentioned In Mb. Nserial No- Repaired At Site Shall Be Mentioned In Mb. Nnote: N ( A ) New Spare Parts Will Be Measured And Paid Separately As Supply Only Under The Respective Items. N ( B ) Cost Of Cleaning, Welding, Minor Repair And Special Tools And Plants Required For Dismantling Engine Will Deemed To Be Included In Quoted Rate. N ( C ) Transportation Cost Of Spare Parts Of Diesel Engine / Alternator To Workshop Shall Deemed Included In Quoted Rate. 75 Description All As Per Serial Item No- 74.00 Here-In-Before But For Engine Of Diesel Driven Diesel Generator Of Capacity 40 Kva To 63 Kva. 76 Supply Only Following New Spare Parts Required For Repair Of Diesel Engine Of Dg Set Capacity 20 To 30 Kva :- 77 Lube Oil Filter. 78 Fuel Oil Filter Insert. 79 Fuel Oil Filter Paper. 80 Fuel Oil Pre-Filter. 81 Air Filter Primary. 82 Air Filter Secondary. 83 Hose Pipe With Clips And Joint Set. 84 Hose Pipe With Clips And Joint Set. 85 Solinoid Switch. 86 Fan Belt For Water Pump Assembly. 87 Fan Belt / Coupling For Alternator Assembly. 88 Supply Only Following New Spare Parts Required For Repair Of Diesel Engine Of Dg Set Capacity 40 Kva To 63 Kva :- 89 Lube Oil Filter. 90 Fuel Oil Filter Insert. 91 Fuel Oil Filter Paper. 92 Fuel Oil Pre-Filter. 93 Air Filter Primary. 94 Air Filter Secondary. 95 Hose Pipe With Clips And Joint Set. 96 Hose Pipe With Clips And Joint Set. 97 Solinoid Switch. 98 Fan Belt For Water Pump Assembly. 99 Fan Belt / Coupling For Alternator Assembly. 100 Amount Of Schedule Of Credit Of For Rs 3, 60, 460.00 Shall Be Deducted From Quoted Amount.

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/ MAINT TO TRANSFORMER, VOLTAGE STABLIZER, STREET LIGHT, DG SET AND OTHER CONNECTED ITEMS AT RAKHMUTHI UNDER GE (SOUTH) AKHNOOR.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 SCHEDULE 'A' PART-I: BOQ OF WORKS FOR E/M WORKS.
2 2 Disconnecting electrical connections from HT and LT sides of old serviceable/ damaged/ burnt step down transformers of any descriptions, capacity exceeding 25 KVA but not exceeding 100 KVA, any type and taking down from the platforms or mounted on exisiting position (four poles/ two pole structure) by hydraulic cranes of suitable capacity and transporting by truck/ lorry to the workshop, opening top cover, draining out the transformer oil in clean barrels, cleaning of sludge from oil tank and conservator tank, cleaning and polishing of tapping contact point, opening carefully copper wire/ strip wound LT coils and rewinding the same after providing new necessary insulating packing material by using the same old strip/ wire, refitting top cover with replacement of studs, nuts, bolts, washers and gasket after repairs/ replacement of unserviceable parts and cleaning the transformer and making the transformer absolutely leak proof, pouring in the insulating oil in the transformer, placing in original position on four pole/ two pole structure/ platform at site and making all HT/LT connections including testing the transformer after necessary repairs, complete all as specified and as directed by Engineer-In-Charge. \nNote: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ. 6 Each Job
3 3 Description all as serial item No- 2.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 160 KVA. 6 Each Job
4 4 Description all as serial item No- 2.00 here-in-before but for transformer of capacity exceeding 160 KVA but not exceeding 250 KVA. 3 Each Job
5 5 Description all as serial item No- 2.00 here-in-before but for transformer of capacity exceeding 250 KVA but not exceeding 400 KVA. 3 Each Job
6 6 Supply and fixing in replacement of HT coil of transformer capacity 25 KVA to 400 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge.\nNote: HT coil shall have same number of turns of winding wire and with matching to manufacturer design.\nMake: ATLAS/ HTP/ BIC. 160 Per Kilogram
7 7 Supply and fixing in replacement of LT coil of transformer capacity 25 KVA to 400 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed.\nNote: LT coil shall have same number of turns of winding wire and with matching to manufacturer design.\nMake: ATLAS/ HTP/ BIC. 120 Per Kilogram
8 8 Replacement of old unserviceable/ damaged HT bushing assembly with new HT bushing assembly (Set of three) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 25 KVA to 100 KVA, complete all as specified and as directed. 6 Each Set
9 9 Description all as serial item No- 8.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 9 Each Set
10 10 Description all as serial item No- 8.00 here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 3 Each Set
11 11 Replacement of old unserviceable/ damaged LT bushing assembly with new LT bushing assembly (Set of Four) with insulated brass stud including nuts, bolts and washers, suitable for transformer of any type, capacity 25 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. 6 Each Set
12 12 Description all as serial item No- 11.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 9 Each Set
13 13 Description all as serial item No- 11.00 here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 3 Each Set
14 14 Replacement of old unserviceable/ damaged temperature gauge with new temperature gauge, suitable for transformer of any type, capacity 25 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. 1 Each
15 15 Description all as serial item No- 14.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 1 Each
16 16 Description all as serial item No- 14.00 here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 1 Each
17 17 Replacement of old unserviceable/ damaged tap changing assembly with new tap changing assembly, off load, on HT winding to vary the voltage ±7.5%, in steps of 2.50%, including necessary connection, HT winding, re-insulation for complete functioning of tap changer, transformer capacity 25 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. 2 Each
18 18 Description all as serial item No- 17.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 2 Each
19 19 Description all as serial item No- 17.00here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 2 Each
20 20 Dehydration and filtration of transformer oil after draining out oil from transformer by the dehydration machine at site or nearby transformer workshop to achieve di-electric strength 40 KV at 4mm gap, complete all as specified and as directed by Engineer-In-Charge.\nNote: \n(i) Cost of transportation of dehydration machine and other required materials and tools, plants shall be deemed to be included in the quoted rates.\n(ii) Test certificate of di-electric strength shall be produce before and after dehydradation and filtration process. 3500 Per Litre
21 21 Replacement of old unserviceable/ damaged air breather assembly with new air breather assembly with silica gel suitable for 11/0.433 KV transformer including nuts, bolts and washers, suitable for transformer 25 KVA to 100 KVA, complete all as specified and as directed by Engineer-In-Charge. 3 Each
22 22 Description all as serial item No- 21.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 3 Each
23 23 Description all as serial item No- 21.00 here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 1 Each
24 24 Supply only fresh transformer oil to top-up and filling in the existing transformer, di-electric strength not than 45 KV, meeting Bureau of Indian Standards: IS 335-1993 (Reaffirmed-2005) specification, examined in a 100mm thick layer at 270°C, clear, transparent and free from all type of suspended matter or sediment, complete all as specified and as directed by Engineer-In-Charge.\nMake: IOCL/ HPCL/ BPCL/ Reliance. 800 Per Litre
25 25 Preparation of old, external surface of transformers capacity 25 KVA to 100 KVA, by removing the scrap, rust, washing including cleaning and spray painting with two coats of synthetic enamel paint including numbering MES No in white colour synthetic enamel paint, at site or at workshop, complete all as specified and as directed by Engineer-In-Charge. 6 Each Job
26 26 Description all as serial item No- 25.00 here-in-before but for transformer of capacity exceeding 100 KVA but not exceeding 200 KVA capacity. 9 Each Job
27 27 Description all as serial item No- 25.00 here-in-before but for transformer of capacity exceeding 200 KVA but not exceeding 400 KVA capacity. 3 Each Job
28 28 Disconnecting electric connections of servo voltage stabilizers, capacity 15 KVA to 30 KVA, draining out the transformer oil in clean barrels for re-use, cleaning of sludge from oil tank and transporting to workshop for repairs and return back to it's original position after repairs including loading and unloading by mechenical means, complete all as specified and as directed by Engineer-In-Charge. \nNote: Spares required for repair/ replacement of unserviceable parts shall be measured and paid separately under relevant items of BOQ. 3 Each Job
29 29 Description all as serial item No- 28.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Each Job
30 30 Description all as serial item No- 28.00 here-in-before but for servo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Each Job
31 31 Replacement of old unserviceable Printed Circuit Board (PCB) with new Printed Circuit Board (PCB) of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 3 Each
32 32 Description all as serial item No- 31.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Each
33 33 Description all as serial item No- 31.00 here-in-before but forservo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Each
34 34 Replacement of old unserviceable carbon bushes with new carbon bushes of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 3 Set of Three
35 35 Description all as serial item No- 34.00 here-in-before but for servo voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Set of Three
36 36 Description all as serial item No- 34.00 here-in-before but for servo voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Set of Three
37 37 Replacement of old unserviceable servo motor with new servo motor of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 2 Each
38 38 Description all as serial item No- 37.00 here-in-before but for voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Each
39 39 Description all as serial item No- 37.00 here-in-before but for voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Each
40 40 Digital voltmeter, range 0-500 Volts, size 96mmx96mm, flush type, complete all as specified and as directed by Engineer-In-Charge. 3 Each
41 41 Digital ammeter, range 0-100 Amps, size 96mmx96mm, square shape, complete all as specified and as directed by Engineer-In-Charge. 2 Each
42 42 Selector switch suitable for Voltmeter/ Ammeter as per existing design and range, complete all as specified and as directed by Engineer-In-Charge. 5 Each
43 43 Replacement of old unserviceable Servo Dimmer Booster Coil with new Servo Dimmer Booster Coil, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 2 Each
44 44 Description all as serial item No- 43.00 here-in-before but for voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Each
45 45 Description all as serial item No- 43.00 here-in-before but for voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Each
46 46 Replacement of old unserviceable control wiring with new control wiring of voltage stabilizer as per existing make and type, capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 3 Each
47 47 Description all as serial item No- 46.00 here-in-before but for voltage stabilizer of capacity exceeding 30 KVA but not exceeding 100 KVA capacity. 1 Each
48 48 Description all as serial item No- 46.00 here-in-before but for voltage stabilizer of capacity exceeding 100 KVA but not exceeding 250 KVA capacity. 1 Each
49 49 Supply and fixing in replacement/ re-winding of transformer coil of voltage stabilizer of capacity 25 KVA to 400 KVA, made of super enameled copper winding wire/ strip of existing insulation, gauge and specifications, complete all as specified and as directed by Engineer-In-Charge.\nNote: Transformer coil shall have same number of turns of winding wire and with matching to manufacturer design.\nMake: ATLAS/ HTP/ BIC. 65 Per Kilogram
50 50 Replacement of old unserviceable Dimmer Gear set with new cast iron Dimmer Gear set, for automatic voltage corrections, make, type and design as per site requirement, suitable for voltage stabilizer capacity 15 KVA to 30 KVA, complete all as specified and as directed by Engineer-In-Charge. 3 Each
51 51 Description all as serial item No- 50.00 here-in-before but for voltage stabilizer of capacity exceeding 30 KVA but not exceeding 60 KVA capacity. 1 Each
52 52 Description all as serial item No- 50.00 here-in-before but for voltage stabilizer of capacity exceeding 60 KVA but not exceeding 100 KVA capacity. 1 Each
53 53 Construction of fire point having a platform as per standard design/ size and height, constructed in brick work in 1:4 cement mortar, and rendering 15mm thick on brick masonry surfaces in 1:4, plain cement concrete flooring with PCC as per zonal specifications, including roof covering in hut shape with 0.80mm thick plain galvanised iron sheet with angle iron 50x50x6mm and flat iron 40x60mm, fire point shall be painted in red colour synthetic enamel paint after preparation of surfaces having "FIRE POINT" word on top of roof covering in white colour synthetic enamel paint, complete all as specified. \nNote: Cost of following equipments/ accessories shall also be deemed inclusive in quoted rate:\n(a) 03 Nos. of fire extinguishers, discharge Carbon-di-oxide type, having 140Kg/Sqcm working pressure, ISI marked 6.50 Kg capacity with hose pipe, conforming to IS-2873, complete in all respect to working in any emergency situation and temperature between -30 to +55 degree centigrade.\n(b) Fire bucket duly paint in red colour and filling with fine sand- 02 Nos.\n(c) Fire beater duly painted in red colour- 02 Nos.\n(d) Shovel with long handle duly painted in red colour- 02 Nos.\n(e) Fire hook duly painted in red colour- 02 Nos. 1 Each Job
54 54 Broken stone aggregate for loose filling in the area sarroundings of transformer, of gauge 20 mm to 40 mm graded, laying in layers thickness not exceeding 150mm, complete all as specified and as directed by Engineer-In-Charge. 10 Cum
55 55 Replacement of old unserviceable rubber mat with new synthetic rubber insulating mat for preventing HT shock, thickness not less than 25mm, size 2.00x1.00 mtrs, complete all as specified and as directed by Engineer-In-Charge. 5 Each
56 56 Display board, size 1.50x1.20x0.30 mtrs, and cubical type, made of 3.0mm thick acrylic sheet (transparent type) of superior quality having installation details in approved colour letters atleast 12mm wide and 100mm high, cubical shall be fixed on painted angle iron frame of size 40x40x6mm, 1500mm high from ground level, embedded in PCC 1:2:4 below 450mm from ground level, complete all as specified and as directed by Engineer-In-Charge.\nNote: Colour of letters shall be as approved by Engineer-In-Charge. 1 Each Job
57 57 LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 45 Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified.\nMake: Havells cat part No- Endura Pearl Neo SL45WLED757SASYTOPC/ Philips ordering code No- 910925866055 (Product Code- 871869634894900)/ Bajaj ordering code No- 169799 (Product Code- BRTFG 45W LED I). 25 Each
58 58 Replacement of old unserviceable/ damaged cable jointing kit with new cable jointing kit for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, 3.0-core, complete all as specified and as directed by Engineer-In-Charge. 3 Each
59 59 Supply, testing and commissioning in-replacement of air break switch with drop out fuse set 12 insulators, gang operated for 11000 Volts, triple pole, mechanically operated, vertical mounted on insulator and steel frame, with operating mechanism and galvanised iron operating rod, worked from ground level, consisting HT insulators as per ISS/ BSS, non ferrous knife and spring loaded contacts, arcing horns of adequate section to break magnetising current of TF’s for current rating upto 200 Amps, complete all as specified and as directed by Engineer-In-Charge. 2 Each
60 60 Replacement of old unserviceable lightning arresters with new lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amp, suitable for 11000 Volts, complete all as specified and as directed by Engineer-In-Charge. 2 Set of Three
61 61 Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.\nNote: \nEarth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.\n 10 Each Set
62 62 Taking down existing unserviceable/ rusted structural steel in cross arms, complete all as specified and as directed by Engineer-In-Charge. 2 Per Quintal
63 63 Mild steel in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint, complete all as specified and as directed by Engineer-In-Charge. 1.5 Per Quintal
64 64 Description all as serial item No- 63.00 here-in-before but except new cross arms of mild steel.\nNote: Quotyed rate shall be deemed inclusive inclusive of one coat of red oxide primer, one under coat and one finishing coat of aluminium paint. 0.5 Per Quintal
65 65 Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and adjustable magnetic setting, 200 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.\nMake: ABB cat part No- 1SDA068109R1 or equivalent in L&T/ Merlin Gerin/ Siemens. 3 Each
66 66 Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.\nMake: ABB cat part No- 1SDA067039R1 equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens. 5 Each
67 67 Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% and Icu as per IEC 60947-2, complete all as specified and as directed by Engineer-In-Charge.\nMake: ABB cat part No- 1SDA067037R1 or equivalent in L&T/ Legrand/ Merlin Gerin/ Siemens. 4 Each
68 68 Earthing complete with copper earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with copper strip, size 20x3mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed by Engineer-In-Charge.\nNote: \nEarth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces.\n 2 Each Set
69 69 Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed in any other indicated situation for loop earthing etc. as required, copper strip 20x3.0mm with saddles and fixing, complete all as specified and as directed. 10 Per Running Metre
70 70 Replacement of old unserviceable/ damaged industrial cable with new industrial cable, PVC insulated, round, heavy duty electric power cable with copper conductor, 1100 Volts grade, cross-sectional area 2.50 Sqmm, 4.0-core, including suitable lugs and accessories for making connections, complete all as specified and as directed. 100 Per Running Metre
71 71 Replacement of old unserviceable/ damaged industrial cable with new industrial cable, PVC insulated, round, heavy duty electric power cable with copper conductor, 1100 Volts grade, cross-sectional area 2.50 Sqmm, 8.0-core, including suitable lugs and accessories for making connections, complete all as specified and as directed. 100 Per Running Metre
72 72 Replacement of old unserviceable/ damaged industrial cable with new industrial cable, PVC insulated, round, heavy duty electric power cable with copper conductor, 1100 Volts grade, cross-sectional area 4.0 Sqmm, 4.0-core, including suitable lugs and accessories for making connections, complete all as specified and as directed. 75 Per Running Metre
73 73 Replacement of old unserviceable/ damaged industrial cable with new industrial cable, PVC insulated, round, heavy duty electric power cable with copper conductor, 1100 Volts grade, cross-sectional area 4.0 Sqmm, 8.0-core, including suitable lugs and accessories for making connections, complete all as specified and as directed. 75 Per Running Metre
74 74 Disconnecting all electric connections from alternator and fuel connection from engine, decoupling of engine and alternator, of diesel driven diesel generator of capacity 20 to 30 KVA, for servicing and minor repair, and carrying out the servicing after de-assembling the external engine assembly, cleaning/ washing the engine outer body and oiling other movable parts, replacing defective spare parts with new spare parts as required for smooth functioning of diesel engine to avoid any break down, servicing at the engine in existing position complete and testing on completion, all as specified and as directed by Engineer-In-Charge.\nMake: Repaired at site shall be mentioned in MB.\nSerial No- Repaired at site shall be mentioned in MB.\nNote:\n(a) New spare parts will be measured and paid separately as supply only under the respective items.\n(b) Cost of cleaning, welding, minor repair and special tools and plants required for dismantling engine will deemed to be included in quoted rate.\n(c) Transportation cost of spare parts of diesel engine/ alternator to workshop shall deemed included in quoted rate. 6 Each Job
75 75 Description all as per serial item No- 74.00 here-in-before but for engine of diesel driven diesel generator of capacity 40 KVA to 63 KVA. 7 Each Job
76 76 Supply only following new spare parts required for repair of diesel engine of DG Set capacity 20 to 30 KVA :-
77 76.01 Lube Oil Filter. 6 Each
78 76.02 Fuel Oil Filter insert. 6 Each
79 76.03 Fuel Oil Filter paper. 6 Each Set
80 76.04 Fuel Oil Pre-filter. 6 Each Set
81 76.05 Air Filter Primary. 6 Each Set
82 76.06 Air Filter Secondary. 6 Each Set
83 76.07 Hose pipe with clips and joint set. 6 Each Set
84 76.08 Hose pipe with clips and joint set. 6 Each Set
85 76.09 Solinoid switch. 6 Each
86 76.1 Fan belt for water pump assembly. 6 Each
87 76.11 Fan belt/ coupling for alternator assembly. 6 Each
88 77 Supply only following new spare parts required for repair of diesel engine of DG Set capacity 40 KVA to 63 KVA :-
89 77.01 Lube Oil Filter. 7 Each Set
90 77.02 Fuel Oil Filter insert. 7 Each Set
91 77.03 Fuel Oil Filter paper. 7 Each Set
92 77.04 Fuel Oil Pre-filter. 7 Each Set
93 77.05 Air Filter Primary. 7 Each Set
94 77.06 Air Filter Secondary. 7 Each Set
95 77.07 Hose pipe with clips and joint set. 7 Each
96 77.08 Hose pipe with clips and joint set. 7 Each
97 77.09 Solinoid switch. 7 Each
98 77.1 Fan belt for water pump assembly. 7 Each
99 77.11 Fan belt/ coupling for alternator assembly. 7 Each
100 78 Amount of Schedule of credit of for Rs 3,60,460.00 shall be deducted from quoted amount.
Disclaimer :