Repair And Maintenance Of Internal Wiring And Accessories Including Fittings And Fixtures , Ceiling Fans , Exhaust Fans , Geysers , Building Earthing Etc For Tech Area , Otm Accn At Afs Hakimpet Under Ge ( Af ) Hakimpet
Tender Overview
Project Description
Repair And Maintenance Of Internal Wiring And Accessories Including Fittings And Fixtures , Ceiling Fans , Exhaust Fans , Geysers , Building Earthing Etc For Tech Area , Otm Accn At Afs Hakimpet Under Ge ( Af ) Hakimpet
BOQ
| NAME OF WORK : REPAIR AND MAINTENANCE OF INTERNAL WIRING AND ACCESSORIES INCLUDING FITTINGS AND FIXTURES, CEILING FANS, EXHAUST FANS, GEYSERS, BUILDING EARTHING ETC FOR TECH AREA, OTM ACCN AT AFS HAKIMPET UNDER GE(AF) HAKIMPET | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Taking down copper / aluminum point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fittings etc removing materials and making good disturbed surfaces of walls, floors etc, including paint tuch up to match with the existing surface as per site requirement, complete all as specified and directed. | 251 | Point | |
| 2 | 2 | Taking down existing unserviceable distribution board, switch fuse unit, enclosure for MCCB / MCB / DB (including MCBs of any type and capacity) and making good the disturbed surface of walls including paint touchup to match with the existing surfaces, complete all as specified and directed. | 310 | Each | |
| 3 | 3 | Taking down existing old unserviceable submain wiring of any description /type size and removal of unserviceable material out of site and making good the disturbed surface of walls / ceiling so as to match with the existing finishes, complete all as specified and directed. | 670 | RM | |
| 4 | 4 | M&L for point wiring with 1.5 Sqmm FRLS insulated multistranded copper conductor, 1100 volts grade single core PVC insulated and unsheathed cable drawn through and including rigid PVC conduit of suitable size but not less than 20 mm dia medium grade on surface of stone/concrete wall /roof etc all as per site requirement including FRLS, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made of 1.6 mm thick MS sheet with sink into the wall for mounting, 60mm deep covered including laminated sheet cover 3mm thick laminated hylam sheet fixed with cadmium plated screws/PVC gang box fully enclosed type for mounting switches,sockets,fan regulator, etc including making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement, complete all as specified and directed for:- | |||
| 5 | 4.01 | One light /Bell /Exhaust fan point controlled by one switch | 60 | Point | |
| 6 | 4.02 | One 3 pin 6 Amps socket point controlled by one switch on same board | 15 | Point | |
| 7 | 4.03 | One 3 pin 6 Amps socket point controlled by one switch on independent board | 15 | Point | |
| 8 | 4.04 | One ceiling fan point controlled by one switch and regulator | 15 | Point | |
| 9 | 5 | All as per item No. 4 here-in-before but with 2.5 Sqmm for 3 pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor, complete all as specified and directed. | 30 | Point | |
| 10 | 6 | M&L for point wiring with 1.5 Sqmm FRLS insulated multistranded copper conductor, 1100 volts grade single core PVC insulated and unsheathed cable drawn through existing concealed rigid PVC conduit including FRLS, PVC insulated and unsheathed cable with copper conductor cable of size 1.50 sqmm as earth conductor as per proper colour coding and pressed steel terminal boxes made of 1.6 mm thick MS sheet box, 60mm deep covered with 3mm thick laminated hylam sheet fixed with cadmium plated screws for mounting switches, sockets, fan regulator, etc including making good the disturbed surfaces of walls and paint tuch up to match with the existing surfaces as per site requirement, complete all as specified and directed for:- | |||
| 11 | 6.01 | One light /bell /Exhaust fan point controlled by one switch | 60 | Point | |
| 12 | 6.02 | One 3 pin 6 Amps socket point controlled by one switch on same board | 12 | Point | |
| 13 | 6.03 | One 3 pin 6 Amps socket point controlled by one switch on independent board | 12 | Point | |
| 14 | 6.04 | One ceiling fan point controlled by one switch and regulator | 12 | Point | |
| 15 | 7 | All as per item No. 6 here-in-before but with 2.5 Sqmm for 3 Pin 16 Amps socket point controlled by one switch on independent board and 2.5 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and directed. | 20 | Point | |
| 16 | 8 | S&F Switch piano flush type, single pole one way 6 Amps 240 volts, complete all as specified and as directed. | 600 | Each | |
| 17 | 9 | S&F Bell push,flush type, 6 Amps, 240 Volts, complete all as specified and as directed. | 60 | Each | |
| 18 | 10 | S&F Switch socket combination, 3 pin 6 Amps, flush type, universal, 240 volts, complete all as specified and directed | 750 | Each | |
| 19 | 11 | S&F Switch socket combination 2 in 1, 3 pin, 6 Amps / 16 Amps, flush type, universal, 240 volts, complete all as specified and directed. | 540 | Each | |
| 20 | 12 | S&F Call bell, Ding dong, AC 240 Volts, complete all as specified and directed. | 60 | Each | |
| 21 | 13 | S&F Stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz Single module, 5 steps flush type, complete all as specified and directed. | 375 | Each | |
| 22 | 14 | S&F Stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module, 5 steps flush type, complete all as specified and directed. | 380 | Each | |
| 23 | 15 | S&F Ceiling rose 6 A, 3 terminal,PVC/polycarbonate ,insulated body 240 Volt , 50 Hz, complete all as specified and directed. | 100 | Each | |
| 24 | 16 | S&F Switch modular type, single pole one way 6 Amps 240 Volts, complete all as specified and directed. | 100 | Each | |
| 25 | 17 | S&F in replacement of Bell push, modular type, 6 Amps, 240 Volts ISI marked, complete all as specified and directed. | 6 | Each | |
| 26 | 18 | S&F in replacement of Switch socket combination 2 in 1, 3 Pin 6 Amps, modular type, universal, 240 volts, complete all as specified and directed. | 60 | Each | |
| 27 | 19 | S&F in replacement of Switch socket combination 2 in 1, 3 Pin 16 Amps, modular type, universal, 240 volts, complete all as specified and directed. | 100 | Each | |
| 28 | 20 | S&F in replacement of Stepped type electronic fan regulator 100 Watt, 240 Volt, 50 Hz 2 module size in 5 steps modular type, complete all as specified and directed. | 100 | Each | |
| 29 | 21 | S&F in replacement of batten / angle holder, PVC / Polycarbonate type back plate, 240 V, 50Hz, suitable for batten fittings, complete all as specified and directed. | 300 | Each | |
| 30 | 22 | M&L for submain wiring alongwith earth wire with 3 runs of 4.0 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through existing PVC conduit in wall/roof surfaces, complete all as specified and directed. \nNote: Three runs of 4.0 Sqmm copper cable shall be measured as one unit length. | 340 | RM | |
| 31 | 23 | All as per item No. 22 here-in-before but with 3 runs of 6.0 Sqmm FRLS PVC insulated copper conductor cable complete all as specified and directed. \nNote: Three runs of 6.0 Sqmm copper cable shall be measured as one unit length. | 100 | RM | |
| 32 | 24 | M&L for submain wiring alongwith earth wire with 3 runs of 4.0 Sqmm FRLS PVC insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including PVC rigid conduit medium grade and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed.\nNote: Three runs of 4.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. | 120 | RM | |
| 33 | 25 | All as per item No. 24 here-in-before but with 3 runs of 6.0 Sqmm FRLS PVC insulated copper conductor cable complete all as specified and directed.\nNote: Three runs of 6.0 Sqmm copper cable and one run of PVC conduit shall be measured as one unit length. | 50 | RM | |
| 34 | 26 | M&L for submain wiring alongwith earth wire with 3 runs of 4.0 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core, drawn through and including steel conduit medium grade and its all accessories of suitable size on wall/roof surfaces complete all as specified and directed.\nNote: Three runs of 4.0 Sqmm copper cable and one run of steel conduit shall be measured as one unit length. | 60 | RM | |
| 35 | 27 | Supply and fix distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 8 way vertical type sheet steel powder painted with bus bar, neutral link & earth bar etc, with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring, complete all as specified and directed. | 1 | Each | |
| 36 | 28 | All as per item No. 27 above but of TPN 4 way. | 2 | Each | |
| 37 | 29 | Supply and fix MCB distribution board double door type SPN 12 way sheet steel powder painted with bus bar, neutral link & earth bar etc, with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing circuit complete all as specified and directed. | 8 | Each | |
| 38 | 30 | All as per item No. 29 above but of SPN 8 way. | 6 | Each | |
| 39 | 31 | All as per item No. 29 above but of SPN 4 way. | 4 | Each | |
| 40 | 32 | Supply and fixing in replacement of sheet metal powder painted double pole enclosure with a two pin and earth plug and socket flushing in wall including 20 Amps rated double pole MCB 10 KA, \"C\" curve complete all as specified and directed. | 15 | Each | |
| 41 | 33 | Supply and fixing in replacement of sheet metal powder painted triple pole and neutral enclosure with a three pin and earth plug and socket flushing in wall including 32 Amps rated three pole MCB 10 KA, \"C\" curve complete all as specified and directed. | 2 | Each | |
| 42 | 34 | Supply and fixing in replacement of MCB Triple pole and Neutral (TPN) of capacity 63 Amps 415 volts, breaking capacity 10 KA, \"C\" series, fixed in proper position, complete all as specified and directed. | 20 | Each | |
| 43 | 35 | Supply and fixing in replacement of MCB, SPN, 30-63 Amps, 240 Volts | 30 | Each | |
| 44 | 36 | Supply and fixing in replacement of MCB , SP, 6 - 32 Amps, 240 Volts | 200 | Each | |
| 45 | 37 | Supply and fixing in replacement of MCCB 125 Amp four pole 415 Volt, breaking capacity 16 KA, with fixed thermal & magnetic setting, complete all as specified and directed. | 10 | Each | |
| 46 | 38 | Supply and fixing in replacement of MCCB 100 Amp four pole 415 Volt, breaking capacity, 25 KA, with fixed thermal & magnetic setting complete including taking down old unserviceable MCCBs, complete all as specified and directed. | 10 | Each | |
| 47 | 39 | Supply and Fix including taking down old unserviceable of following items, complete all as specified and directed:- | |||
| 48 | 39.01 | LED driver suitabe for 2x2 LED Panel of any make mentioned below as directed from 18 watt to 42 watt. Make: Havells/Philips/CG/Bajaj | 30 | Each | |
| 49 | 39.02 | LED driver suitabe for 1x1 LED Panel of any make mentioned below as directed from 28 watt to 42 watt. Make: Havells/Philips/CG/Bajaj | 10 | Each | |
| 50 | 39.03 | LED T5 Full Glass Tube 4ft retrofit double end Direct to Mains 240V AC • 16W • 4000K • G5. Make : Havells/Philips/CG | 100 | Each | |
| 51 | 39.04 | LED tube rod 20 watt retofit double ended suitable for existing 36/40 watt FTL batten. Make :- Havells - CRYSTAL 1213T8DSTL13WLED865SGLASS or equivalent in Phillips/CG. | 1400 | Each | |
| 52 | 39.05 | Bi-pin Holder suitable for 36/40 watt batten. | 100 | Each set | |
| 53 | 40 | Supply & fixing wall mounted LED batten, with extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver for 12W LED (2ft) complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:-Havells /Philips/CG. | 300 | Each | |
| 54 | 41 | Supply & fixing LED light fitting,10 watt bulk head luminaries complete with all accessories and including connecting up with twin core twisted gflexible copper conductor cable of suitable size complete all as specified and as directed. Make :- Havells Cat No. RUGBYNEONFT10WLED860SSYMTOPC or equivalent in Phillips / CG. | 30 | Each | |
| 55 | 42 | Supply & fixing high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extrured diffuser giving glare free light and good aesthetic appeal 18 W LED 6000K (1ft X 1ft) complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size, complete all as specified and directed. Make :- Havells Cat No. LHEAAWP7IL1W018 or its equivalent in Philips/CG. | 16 | Each | |
| 56 | 43 | Supply & fixing high efficacy recess luminaire suitable for armstrong/grid ceiling with high brightness LEDs and PMMA extrured diffuser giving glare free light and good aesthetic appeal 36 W LED 5700K (2ft X 2ft) complete with all accessories including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make :- Philips Cat No. VENUSNEO2X2PLR18-48WLED830MOD or its equivalent in Havells/CG. | 40 | Each | |
| 57 | 44 | Disconnecting ceiling fans of any sweep and from any height including electrical connections, bringing down, dismantling, opening up, cleaning internally and externally, overhauling by replacing unserviceable items such as split pins, bearings, bushes, copper flexible cord, cotter pins and check nuts etc, lubrication with approved lubricants, reassembling including replacement of worn-out /defective parts and refixing for smooth functioning and connecting cable from ceiling rose to fan including testing, complete all as specified and directed. | 850 | Each | |
| 58 | 44.01 | Note for item No. 44 : Replacement of unserviceable spare parts required for servicing/overhauling and rewinding of fans shall be measured and paid separately under supply only vide Item No. 45 of this schedule. | |||
| 59 | 45 | Supply only the following items suitable for ceiling fans of any make / sweep for incorporation in item No.43 above, complete all as specified and as directed. | |||
| 60 | 45.01 | Capacitor 2.5 mfd capacity 240 Volts. Make : CAPCO/TIBCON | 500 | Each | |
| 61 | 45.02 | Ball bearing of suitable size. Make : NBC/SKF/TATA. | 200 | Each | |
| 62 | 45.03 | Gun metal bush | 100 | Each | |
| 63 | 45.04 | Copper flexible cord 3 core of size 23/00076 | 630 | RM | |
| 64 | 45.05 | Fan Clamp with rubber bush | 40 | Each | |
| 65 | 45.06 | Fan Down rod, 400 mm long | 15 | Each | |
| 66 | 45.07 | Painting of Fan of any size and make, by spray painting in one coat including writing fan numbers. | 50 | Each | |
| 67 | 46 | All as per Ser item No.44 above here before but exhaust fan / wall mounting fan / Pedestal fan of sweep 230/300/375/450 mm complete all as specified and directed. | 60 | Each | |
| 68 | 46.01 | Note for item No. 46 : Replacement of unserviceable spare parts required for servicing/overhauling and rewinding of fans shall be measured and paid separately under supply only vide Item No. 47 of this schedule. | |||
| 69 | 47 | Supply only the following items suitable for Exhaust/Pedestal fan of any make / sweep for incorporation in item No.46 above compplete all as specified and as directed;- | |||
| 70 | 47.01 | Capacitor 4 mfd capacity 240 volts. Make : CAPCO / TIBCON | 10 | Each | |
| 71 | 47.02 | Ball bearing of suitable size. Make : NBC / SKF / TATA | 15 | Each | |
| 72 | 48 | Taking out burnt copper winding wire from fan, cleaning the rotor shaft properly and rewinding with new super enamelled copper winding wire as per existing size/ gauge including heating/ varnishing etc complete as per manufacturer's design for the following fans:- | |||
| 73 | 48.01 | Ceiling fan of 1200/1400 mm sweep | 760 | Each | |
| 74 | 48.02 | Exhaust fan of 230/300 mm sweep | 30 | Each | |
| 75 | 48.03 | Exhaust fan of 375/450/305/380 mm sweep | 30 | Each | |
| 76 | 48.04 | Wall mounting/Padestal fan of 400/450 mm sweep | 25 | Each | |
| 77 | 49 | S&F Louvers with suitable frame work and fixing arrangements for exhaust fan of any size sweep complete including removing the existing unserviceable one, complete all as specified and directed. | 10 | Each | |
| 78 | 50 | S&F Flap cover with suitable frame work and fixing arrangements for exhaust fan of size 230/300/450 mm sweep complete including removing the existing unserviceable one, complete all as specified and directed. | 10 | Each | |
| 79 | 51 | Taking Down water heater (Electric Geyser) storage type of any make of 25 / 50 ltr capacity after disconnecting the existing electrical connection, water pipes and reassembling in all respects after replacing unserviceable parts/components and testing for proper working after repairs and refixing in the original place/position duly connecting up water supply and electric supply etc, complete all as specified and directed. Note :- Spare parts replaced shall be measured and paid separately vide 51.01 to 51.04 . However labour cost of replacement is deemed to be included in the rate quoted. | 40 | Each | |
| 80 | 52 | Supply only the following parts of water heater (Electric Geyser) storage type of given make and size, complete all as specified and directed:- | |||
| 81 | 52.01 | Thermostat suitable for 25/50 Litre capacity. Make : Sphare hot /Bajaj/Ditz/Picco/Usha /Racold / Venus. | 20 | Each | |
| 82 | 52.02 | Heating element 1500 Watt 240 Volts push/thread type circular/ triangular base for any make and type. Make: Bajaj / Racold / Venus. | 35 | Each | |
| 83 | 52.03 | Heating element 2000 Watt push/thread type circular /triangular base suitable for Venus Model No. 25 VLM/2016 or equivalent make in Bajaj / Racold. | 35 | Each | |
| 84 | 52.04 | Indicator bulb 240 V suitable for given make, type and model | 5 | Each | |
| 85 | 53 | S&F Pressure release valve suitable for 25/50 Litre capacity geyser including taking out the existing unserviceable one all as specified and directed. Make -Sphare Hot / Bajaj / Ditz /Picco / Usha . | 5 | Each | |
| 86 | 54 | S&F gasket rubber suitable for geyser of capacity 25/50 litre including taking out the existing unserviceable one, ccomplete all as specified and directed. | 15 | Each | |
| 87 | 55 | S&F in replacement of non return valve gunmetal for 15 mm bore with suitable fittings. Make - Kirloskar / Leader /Kartar . | 10 | Each | |
| 88 | 56 | S&F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for cold water connection. | 10 | Each Set | |
| 89 | 57 | S&F in replacement of PVC connection 15 mm dia 450 mm long with PTMT nuts on both sides for hot water connection. | 10 | Each Set | |
| 90 | 58 | S&F in replacement of PVC insulated and PVC Sheathed round Copper Cable flexible 3 core x 2.5 Sq mm from Geysers to socket. | 300 | RM | |
| 91 | 59 | S&F in replacement of PVC insulated and PVC sheathed flexible Copper Cable 3 core x 4.0 Sq mm from Geysers to socket. | 300 | RM | |
| 92 | 60 | S&F in replacement of plug top 3 pin 6 Amps 240 Volts. Make : Anchor / Leader / Havells. | 50 | Each | |
| 93 | 61 | S&F in replacement of plug top 3 pin 16 Amps 240 Volts. Make : Anchor / Leader / Havells. | 60 | Each | |
| 94 | 62 | Supply and fixing in replacement of Weather proof flat twin core cable size 6 Sqmm aluminium conductor PVC insulated and PVC sheathed, complete all as specified and directed.. | 300 | RM | |
| 95 | 63 | Supply and fixing in replacement of Weather proof flat twin core cable size 10 Sqmm aluminium conductor PVC insulated and PVC sheathed, complete all as specified and directed.. | 300 | RM | |
| 96 | 64 | S&F Apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 25 Ltrs capacity geyser including taking out existing unserviceable one, complete all as specified and directed. | 10 | Each | |
| 97 | 65 | Checking of solar water heater of capacity 200/300/500 Ltrs capacity and making serviceable by replacing unserviceable parts, complete all as directed. Note: Supply of spare parts will be measured and paid under item No. 66 below. | 4 | Each Job | |
| 98 | 66 | Supply only the following parts of solar water heater storage compactable to the existing make and size, complete all as specified and directed:- | |||
| 99 | 66.01 | Hose Pipe Pair | 2 | Each Set | |
| 100 | 66.02 | Aluminium dummy gasket | 2 | RM | |
| 101 | 66.03 | EPDM Hole gasket | 2 | Each | |
| 102 | 66.04 | Brass Flange | 2 | Each | |
| 103 | 66.05 | Threaded Flange | 2 | Each | |
| 104 | 67 | S&F Apparatus plate (bottom plate in which element and thermostat are fixed) complete suitable for 50 Ltr capacity geyser including taking out existing unserviceable one, complete all as specified and directed. | 10 | Each | |
| 105 | 68 | M&L for replacing door of existing LT panel / feeder pillar box made of 2mm thick CRCA sheet including provision of locking arrangement & gasketed made of CRCA sheet 2 mm thick including hings, welding and painting in two coats over primer, complete all as specified and directed. | 20 | Sqm | |
| 106 | 69 | S&F Flame proof weather proof LED Tube light fitting suitable for 1 x 18 Watt (4 feet) with borosil make glass & connector suitable for 1 x 18 Watt LED tube light, including all accessories, complete all as specified and directed. Make :- M/S Shyam Switchgears Model No. SSPL/FF/1271 or equivalent make in M/S Sudhir / M/S Baliga. | 6 | Each | |
| 107 | 70 | Repairing/overhauling of TPN/SPN DBs of any size/type fixed on building wall including cleaning with compressed air, tightening of all electric connection to the bus bar & switch gears , refixing of loosed doors with proper fixing & locking arrangement &necessary welding work as required and replacement of wornout/ burnt/rusted/ loose lugs , door lock, nut bolt,hing, washers,internal wiring with suitable size (minimum 1.5 sqmm) of PVC copper conductor wire ,repair to plaster work as require at site and including disconnection of all cable/ sub main from the bus bar and insulating the neked portion of aluminium conductor and re-connect the same after repair of panel and proper connection of main earth wire/lead with panel body using lugs complete all as specified and directed. | 20 | Each | |
| 108 | 71 | M&L for earthing complete with galvanised earth plate electrode 600mm x 600 mm x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connecting to GI wire 4mm dia as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth strip protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion, complete all as specified and directed. \nNotes:- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, earth lead & protection pipe upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part-II. \n | 10 | Each |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender