E-Tender For Supply And Installation Of Laboratory Equipment Forphysics Labs -1 Logic Gates Using Ttl Ics Power Supply, Digital Trainer Kit., Connecting Leads, Ic’S ( 7400, 7402, 7404, 7408, 7432, And 7486 ) . N 2 Logic Gates ( For Verify Boolean Function Using In Both Sop And Pos Forms ) Power Supply, Digital Trainer, Ic’S ( 7404, 7408, 7432 ) Connecting Leads. 3 Rs, J-K, T And D Flip-Flops Using Nand & Nor Gates Ic’ S 7400, 7402 Digital Trainer & Connecting Leads. 4 Decoder / De-Multiplexer And Encoder Using Logic Gates Ic 7447, 7-Segment Display, Ic 74139 And Connecting Leads 5 4X1 Multiplexer Using Logic Gates Power Supply, Digital Trainer, Connecting Leads, Ic’S 74153 ( 4X1 Multiplexer ) N 6 4-Bit Parallel Adder Using 7483 Ic Digital Trainer Kit, Ic 7483 ( 4-Bit Parallel Adder ) . N 7 4- Bit Synchronous Counter Digital Trainer Kit And 4 Jk Flip Flop Each Ic 7 476 ( I.E. Dual Jk Flip Flop ) And Two And Gates Ic 740 8. 8 4-Bit Asynchronous Counter Digital Trainer Kit And 4 Jk Flip Flop Each Ic 7476 ( I.E Dual Jk Flip Flop ) And Two And Gates Ic 7408. 9 Half Adder &Full Adder Power Supply, Ic’S, Digital Trainer, Connecting Leads. 10 Half Subtractor Digital Trainer Kit, Nic 7486 ( Ex-Or ) Nic 7408 ( And Gate ) Nic 7404 ( Not Gate ) N 11 Nand As A Universal Gate Digital Trainer Kit, Ic 7400 ( Nand Gate ) 12 Magnitude Comparator Power Supply, Digital Trainer Kit., Connecting Leads, And Ic’S ( 7404, 7408, And 7486 ) N 13 N-Channel Mosfet Mosfet ( 2N7000 ) , Bread Board, Resistor ( 1K?, 100K? ) , Connecting Wires, Ammeters ( 0-10Ma / 0-25Ma ) , Dc Power Supply ( 0-30V ) And Multimeter N 14 V-I Characteristics Of Zener Diode A 6.2 V Zener Diode, A Dc Voltage Supplier, Bread Board, 100? Resistor, 2 Multimeter For Measuring Current And Voltage, Connecting Wires 15 Input / Output Characteristics Of Transistor Transistor, Variable Power Supplies, Resistors, Voltmeters, Ammeters, Bread Board. N N 16 Magnetic Field ( Helmholtz Coils ) Ic Regulated Constant Current Source, Digital Gauss Meter, Two Coils, Movable Magnetic Field Sensor 17 Stefan’S Constant Diode Ez-81, Ammeter, Voltmeter, Current Source. 18 Four Probe Method Four Probe Apparatus, Sample ( A Ge Crystal In Form Of A Chip ) , Oven, Thermometer ( 2600 ) Constant Power Supply, Oven Power Supply, Panel Meters For Measurement Of Current And Voltage 19 B – H Curve Set Up For B-H Curve, Experimental Material ( Commercial Nickel ) , Cro, Connecting Leads. 20 E / M Experiment ( Magnetron Method ) E / M Apparatus Consisting Of Power Supply Fitted With Voltmeter And Ammeter To Read Anode Nvoltage ( In Volts ) , Anode Current ( Micro Amp ) , Solenoid Power Supply Fitted With Ammeter To Read Solenoid Current ( Amp ) , Magnetron Valve With Base And Connecting Wires, Solenoid Fitted With Suitable Wooden Base. N 21 Viscosity Measurement A Glass Cylinder Of About 5 Cm ( Or More ) In Diameter And About 100 Cm In Length, Few Spherical Nmetal Balls Of Diameters Ranging From 1 To 3 Mm, Stop Watch, Screw Gauge, Meter Scale, Experimental Nliquid N 22 Malus Law A Diode Laser, A Polarizer-Analyzer Pair, Photo Detector, Detector Output Measuring Unit ( Micro Ammeter ) , Dial Fitted To The Polarizer And An Optical Bench 23 Planck’S Constant Filament Bulb With A Filter, Power Supply ( 0-12 V Dc ) , A Photo Cell Fitted On Mini Optical Bench, One Ammeter ( 0- 2 A ) And One Voltmeter ( 0-10 V ) To Read Filament Current And Voltage, One Digital D.C. Microammeter ( 0-200 Μa. ) 24 Single Slit Diffraction Optical Bench, He-Ne Laser, Screen With A Rectangular Slit, Photo Cell, Micro Ammeter 25 Quarter Wave Plate He-Ne Laser With Built In Power Supply, Stand For Laser, Polarizer And Analyzer . Quarter Wave Plate, Laser Detector ( Photo Device ) With Measuring Devices ( Digital Microammeter ) . Screen And Optical Bench With Nsuitable Uprights N 26 Brewster’S Angle He Laser, Dial Fitted Polarizer, Photo Detector, Micro Ammeter, Rotational Mount, Glass Plate, Constant Power Supply 27 Newton’S Rings A Plano-Convex Lens Of Large Radius Of Curvature, Optical Arrangement For Newton’S Rings, Plane Glass Plate, Sodium Lamp And Travelling Microscope 28 Planck’S Constant ( Photo Electric Effect ) Light Source, Digital Voltmeter And Ammeter, Vacuum Photo Tube, Filters Of Different Colors 29 Young’S Modulus Experimental Set Up, A Spirit Level, A Meter Scale, A Screw Gauge And A Vernier Calipers 30 Ultrasonic Waves A Double Walled Cylindrical Vessel ( B ) Containing The Experimental Liquid, An Rf Power Oscillator And A Nquartz Crystal ( Frequency= 3 Mhz ) To Generate Ultrasonic Waves, A Quartz Crystal Plate Fitted With A Nmicrometer Screw, An Acmicroameter Or A Cro N 31 Experiments Related To Pn Junction Study Of P-N Junction ( Pn-01 ) One, Oven One, Sample Set : One, ( Bc-109-Si ; In-34-Ge ; In5408-Diode : Mounted On Teflon Plugs ) 32 Identify The Lattice And To Determine Its Lattice Constant Set Up For X- Ray Simulation, Samples 33 Franck–Hertz Experiment Tetrode Tube Filled With Experimental Argon Gas, Filament, Power Supply Three Variable Voltage Sources, Nanoammeter