Election Department-ED has published Supply Of Fire Fighting Suits With Fire Resistant Hood , Gloves , Helmet And Fire Fighting Boot . Bharatpur. Submission Date for this Tender is 20-03-2020. Coats and Jackets Tenders in Bharatpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

23980653
Supply Of Fire Fighting Suits With Fire Resistant Hood , Gloves , Helmet And Fire Fighting Boot . Bharatpur
Open Tender
Indian
Rajasthan
Bharatpur
20-03-2020

Tender Details

supply of Fire Fighting Suits With Fire Resistant Hood , Gloves , Helmet And Fire Fighting Boot . Bharatpur , specification of fire suit :- fire fighting suit:- specification and design of coat :- 1 . 4- layer construction ( outer shell , moisture layer , thermal layer , inner lining ) . 2 . reinforcements on elbow . 3 . adjustable torch loop and holder . radio pocket for prtable radio 4 . multi layer throat tab to give full protection on throat color option: dark blue . specification and design of pants :- 1 . 4- layer construction as coat 2 . elastic waistband on both sides of the waist . 3 . reinforcements on knees . 4 . anti-wicking strip at hem of pants to prevent water absorbingh . 5 . two side cargo pockets with drainage holes . 6 . hem at leg bottom curved upwards at heel area . color option: dark blue . size :- xxl to xxxl weight ( coat & plants ) :- 3 to 4 kg . outer shell material ( a ) :- inherently fire - resistant fabric , about 90-95% meta-aramid +5- 7% , para-aramid + 2-5% anti static . weight ( b ) :- 200-250g / m2 . weight ( c ) :- twill . moisture layer : it shall be membrane laminated with weave fabric , heat resistant , watet penetration resistant , breathable and blood penetration resistant & blood pathogens resistance . original test report or authenticated copy is required . thermal layer :- it shall be flame-resistant fabriccomposition: 100% aramid . inner lining :- it shall be inherently flame-resistant fabric composition: 50 % aramid with 50 % fr viscose plane weave . threads :- sewing thread used for stitching of fireman suit shall be of heavy duty andinherently flame resistant . zipper :- made by high quality fr zipper . reflective tapes :- reflective material silver / light green jacket and over trouser . note :- bidder will quote rates including gst & other taxes . , 2 . fire resistant hood :- 2 layer construction protects from top to end , including throat . neck and part of shoulders . designed with double rib knitted fabric that allows better scretch of fabrics made by 100% meta-aramid . applied to fully wrap the face with no gaps . the anti-flash hood shall be super soft and comfortable for wearer that feels barrier-less . tube shape design shall be in accord all head sizes . one size fit all . perfectly designed for optimal fit with most scba masks , optional colours in production shall include dark blue . material : 100 % meta-aramid . colour : dark blue . construction : full faced , light weight , double layer . note :- bidder will quote rates including gst & other taxes . , 3 . gloves :- out shell : natural split , durable and soft , water repellent ; low abosorption of water . heat resistance and flame retardant , high abrasion resistance , tear resistance , puncture resistance moisture barrier: flame retardant moisture barrier , durable and breathable; prevent from chemical and blood pathogen : note :- bidder will quote rates including gst & other taxes . , 4 :- helmet :- the helmet should be incredibly light . the optimized shape and low ride height enhance the balanced feel of the helmet to provide you a comfortable fit over longh periods of wear . certification : certification required european norms . note :- bidder will quote rates including gst & other taxes . , 5 . fire fighting boot :- boot height : 14-16 inches lower midsole : 9-10mm coated felt insulation : 4 . 5-5 mm open cell foam toe lining : 70-80 mm net lining calendar coated . lining construction : stiched down linings ensure no liner pull-out , high abrasion nylon heel non-slip provides maximum wear and secure fit . foodbed : extra cushioning , drier , and healthier environment under the foot . steel toe : to meet all standards . stell pr plate : stainless steel to meet all standards . steel shank : double ridged steel . out sole : one piece molded . pull on loops : rubber coated pull-on loops for durability . note :- bidder will quote rates including gst & other taxes .

Key Value

Document Fees
INR 500 /-
EMD
INR 58934.0 /-
Tender Value
INR 29.46 Lakhs /-

BOQ Items

Name of Work: Fire fighting suits with fire resistant hood, Gloves, Helmet and fire fighting boot. Bharatpur
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Specification of Fire Suit :-\nFire Fighting Suit:- \nSpecification and Design of Coat :-\n1. 4- Layer construction (outer shell, moisture layer, thermal layer, inner lining). \n2. Reinforcements on Elbow. \n3. Adjustable torch loop and holder. Radio pocket for prtable radio \n4. Multi layer throat tab to give full protection on throat color option: Dark blue.\nSpecification and Design of Pants :-\n1. 4- Layer construction as Coat \n2. Elastic waistband on both sides of the waist . \n3. Reinforcements on Knees. \n4. Anti-wicking strip at hem of pants to prevent water absorbingh.\n5. Two side cargo pockets with drainage holes. \n6. Hem at leg bottom curved upwards at heel area. color option: Dark blue.\nSize :- XXL to XXXL\nWeight (Coat & Plants):- 3 to 4 Kg.\nOuter Shell material (A) :- Inherently Fire - Resistant Fabric, about 90-95% Meta-aramid +5- 7%, Para-aramid + 2-5% Anti Static.\nWeight (B) :- 200-250g/m2.\nWeight (C) :- Twill.\nMoisture layer : It shall be Membrane laminated with weave fabric, heat resistant, watet penetration resistant, breathable and blood penetration resistant & blood pathogens resistance. Original test report or authenticated copy is required.\nThermal layer :- It shall be flame-resistant fabricComposition: 100% Aramid.\nInner Lining :- It shall be INHERENTLY flame-resistant fabric Composition: 50 % Aramid with 50 % Fr viscose plane weave.\nThreads :- Sewing thread used for stitching of fireman suit shall be of heavy duty andinherently flame resistant. \nZipper :- Made by high quality FR Zipper.\nReflective tapes :- Reflective material silver / light green jacket and over trouser.\nNOTE :- BIDDER WILL QUOTE RATES INCLUDING GST & OTHER TAXES. BI01010001010000000000000515BI0100001114 1 Each
2 2 2. Fire Resistant Hood :- \n2 layer construction protects from top to end, including throat. Neck and part of shoulders. Designed with double rib knitted fabric that allows better scretch of Fabrics made by 100% meta-aramid. Applied to fully wrap the face with no gaps. The anti-flash hood shall be super soft and comfortable for wearer that feels barrier-less. Tube shape design shall be in accord all head sizes. One size fit all. Perfectly designed for optimal fit with most SCBA masks, Optional colours in production shall include Dark Blue. \nMaterial : 100 % Meta-aramid. \nColour : Dark blue. \nConstruction : Full faced, light weight, double layer.\nNOTE :- BIDDER WILL QUOTE RATES INCLUDING GST & OTHER TAXES. BI01010001010000000000000515BI0100001115 1 Each
3 3 3. Gloves :- Out shell : Natural split, durable and soft, water repellent ; low abosorption of water. Heat resistance and flame retardant, high abrasion resistance, tear resistance, puncture resistance Moisture barrier: flame retardant moisture barrier, durable and breathable; prevent from chemical and blood pathogen :\nNOTE :- BIDDER WILL QUOTE RATES INCLUDING GST & OTHER TAXES.\n BI01010001010000000000000515BI0100001116 1 Each
4 4 4 :- Helmet :- The helmet should be incredibly light. The optimized shape and low ride height enhance the balanced feel of the helmet to provide you a comfortable fit over longh periods of wear. Certification : Certification required European Norms. \nNOTE :- BIDDER WILL QUOTE RATES INCLUDING GST & OTHER TAXES. BI01010001010000000000000515BI0100001117 1 Each
5 5 5. Fire fighting Boot :- \nBOOT HEIGHT : 14-16 inches\nLOWER MIDSOLE : 9-10mm coated felt\nINSULATION : 4.5-5 mm open cell foam\nTOE LINING : 70-80 mm net lining calendar Coated.\nLINING CONSTRUCTION : Stiched down linings ensure no liner pull-out, High abrasion nylon heel non-slip provides maximum wear and secure fit.\nFOODBED : Extra cushioning, drier, and healthier environment under the foot.\nSTEEL TOE : To Meet all standards.\nSTELL PR PLATE : Stainless steel To Meet all standards. \nSTEEL SHANK : Double ridged steel.\nOUT SOLE : One piece molded.\nPULL ON LOOPS : Rubber coated pull-on loops for durability.\nNOTE :- BIDDER WILL QUOTE RATES INCLUDING GST & OTHER TAXES. BI01010001010000000000000515BI0100001118 1 Each