| Name of Work:REPAIR AND MAINTENANCE OF SUMMER / WINTER APPLIANCES AT IMA DEHRADUN. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Dismantling and taking out the non-functional Water coolers of any description, any make and in any position of capacity 40 ltr to 150 ltr, including disconnection of water line connections, cleaning and servicing of the water cooler , checking all serviceable parts, necessary brazing, reassembling all parts of water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. \n Note :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item.(ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the water cooler in working condition during the entire contract period and further for defects liability period. | 90 | Each Job | |
| 2 | 2 | Checking of leakage of refrigerent system of water cooler of capacity 40/80/120/150 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom leg suppots and testing and vaccumising the system and supply and filling of oil in required quantity complete all as specified and directed .\nNote :- (i) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item (ii) The new fixed spares/ parts shall be paid as \"supply only\" as specified / mentioned here-in-after and fixing charges for new/ repaired items are deemed to be included under this item | 30 | Each Job | |
| 3 | 3 | Supply only Condensor fan Motor suitable for Water cooler of capacity 40/60/80/120/150 ltr duly connected and testing complete in position all as directed. Make: GE/Crompton/ or equivalent make as approved by GE. | 18 | Each | |
| 4 | 4 | Supply only over load protector suitable for water cooler of capacity 40/60/ 80/ 120/150ltr complete all as directed.Make :- As per sample | 31 | Each | |
| 5 | 5 | Supply only starting capacitor conforming to IS - 2193-1975 AC 230 Volts in Aluminium container capacity 40/60 Mfd complete all as specified and directed. Make:- Havells / TIBCON/Epcos | 34 | Each | |
| 6 | 6 | Supply only running capacitor 25 mfd complete all as specified and directed. Make:- TIBCON /EPCOS / Havells | 38 | Each | |
| 7 | 7 | Supply only running capacitor 10 Mfd complete all as specified and directed. Make:- TIBCON /EPCOS / Havells | 40 | Each | |
| 8 | 8 | Supply only starting capacitor 10 mfd complete all as directed. Make: TIBCON /EPCOS / Havells | 40 | Each | |
| 9 | 9 | Supply only thermostat switch suitable for water cooler capacity 40/60/80/120/150 ltr and any make complete all as directed and approved by GE.Make :- As per sample | 35 | Each | |
| 10 | 10 | Supply only starting relay complete suitable for water cooler of different capacity and any make complete all as specified and directed.\nMake;- Hightech/ Annapurna/ Renutrol/ Sri Ram/ L&T | 30 | Each | |
| 11 | 11 | Supply only push/lifting type self closing tap of 15mm dia chromium plated suitable for Usha Sriram/Sidwal/Voltas/Bluestar make water cooler of different capacity complete all as specified and directed.Make: As per sample | 16 | Each | |
| 12 | 12 | Supply only inner door gasket suitable for Usha Sriram/Sidwa/Voltas/Bluestar make water cooler of different capacity complete all as directed.\nMake & Size: As per sample | 18 | Each | |
| 13 | 13 | Supply only wiring kit suitable for water cooler of various capacity complete all as specified & directed.Make: As per sample | 27 | Each | |
| 14 | 14 | Supply only condensor Fan blade set suitable for Water cooler of capacity 40/60/80/120/150 ltr complete all as directed.Make & Size : As per sample | 16 | Each | |
| 15 | 15 | Supply only PVC drain pipe 2m long of size 25 to 40mm dia complete with 04 Nos hose clip of suitable sizes complete all as directed . \nMake: Kisan/Supreme/Prince/Finolex | 45 | Each | |
| 16 | 16 | Supply only drier filter pencil type suitable for water cooler of different capacity and any make complete all as specified and directed. Make :- Renulrl/Danfar | 27 | Each | |
| 17 | 17 | Supply only stainless steel water tray for safe drinking water suitable for Water cooler of capacity 40/60/80/120/150 ltr and any make complete all as directed.Make & Size : As per sample | 10 | Each | |
| 18 | 18 | PVC float valve 15mm dia with epoxy coated aluminium rod and high density plastic ball min weight 142 gms with Nipple & long screws etc suitable for Water cooler fixed in repair complete all as directed. Make: Prayag / Symeti /shakati enterprises precsion | 38 | Each | |
| 19 | 19 | PVC connection 15 mm size 450 mm long with brass union nuts on both ends suitable for water cooler fixed in repair complete all as directed. Make : Prayag/ Symet shakati enterprises precsion | 48 | Each | |
| 20 | 20 | PVC insulated and sheathed cable 3 core 2.5 sqmm stranded copper conductor fixed in repair complete all as specified and directed. \nMake :-Plaza/Finolex/Havells/Polycab/Shalbh India | 180 | RM | |
| 21 | 21 | Steel water tubing medium grade 15mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed. Make:-Jindal/Prakash/Surya | 35 | RM | |
| 22 | 22 | Steel water tubing medium grade 20mm bore galvanized with all fittings and fixed to walls or through walls / ceiling or laid in floors including cutting, chasing, pining in for concealed portion fixed in repair complete all as specified and directed. Make:-Jindal/Prakash/Surya | 30 | RM | |
| 23 | 23 | Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 15mm bore complete all as specified and directed \n(Make: Sant/Bir/NMC/Zoloto/Leader)\n\n | 8 | Each | |
| 24 | 24 | Dismantling and taking out old unserviceable Gate valve/Globe valve and Supply, fixing, jointing and testing, IS-778 Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe 20 mm bore complete all as specified and directed \n (Make: Sant/Bir/NMC/Zoloto/Leader)\n\n | 5 | Each | |
| 25 | 25 | Repair to rusted and perished body and foundation base frame of water coolers any capacity, make & model including taking down all accessories, condenser, fan motor, spare parts, kit box from water cooler carefully & refixing the same after necessary repairs as required to make the water cooler functional, by providing new MS sheet matching with existing gauge after removing old rusted/ unserviciable portion including replacement of old nut bolts, screw, hinges etc and painting with two coats of synthetic enamel paint over a coat of primer of the same colour over a coat of primer complete all as as directed | 8 | Each Job | |
| 26 | 26 | Preparation of existing decorated surface of water cooler of any capacity,make & model and applying one coat of synthetic enameled paint (white) by spray machine including writing MES No/ SM No in capital letters of height not less than 20 mm on water cooler body in MES pattern and style complete all as specified and directed. | 35 | Each Job | |
| 27 | 27 | Rewinding of blower motor 1/32 HP, 1/35 HP, 1/12 HP AC 240 Volts single phase 50C/S with existing guage of copper winding wire including insulation varnishing and repair of connecting bushes, bearing , blower fan blade,shaft and connection wire and testing complete of water cooler of (Make Shakti) all as specified and directed. | 14 | Each | |
| 28 | 28 | Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 40/80 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. \n | 12 | Each | |
| 29 | 29 | Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 60/120 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. \n | 3 | Each | |
| 30 | 30 | ,Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Usha Sri Ram, Blue star, voltas for Water Cooler 150 ltr capacity fixed in repair complete including testing of nitrogen gas pressure and charging of gas R-134A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. \n | 2 | Each | |
| 31 | 31 | Servicing of Refrigerator cap-165 upto 320 ltrs complete cleaning of storage, cooling/condenser coils etc complete all as directed by Engineer-in-Charge.\nNote :- (i)The rate quoted for servicing shall be inclusive of attending complaints and keeping the refrigerator in working condition during the entire contract period and further for defects liability period.(ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item | 39 | Each Job | |
| 32 | 32 | Checking of leakage of refrigerent system of Refrigerator of capacity 165/190/286 Ltrs to 300/310/320 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom legs suppots and testing and vaccumising the system and supplying and filling of oil in required quantity complete all as specified and directed. \nNote :- (i) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item. | 15 | Each Job | |
| 33 | 33 | Supply only starting relay box type suitable for refrigerator compressor of any make and capacity complete all as directed. \nMake Classic/indofoss/Annapurna/ SriRam /Micro Tech/L&T | 15 | Each | |
| 34 | 34 | Supply only thermostat switch suitable for refrigerator/Deep Freezer of capacity 165 to 320 litrs / 200 to 340 litrs and any make complete all as directed by Engineer-in-charge. \nMake : Indofoss/Dandfoss/Annapurna | 22 | Each | |
| 35 | 35 | Supply only inner door gasket suitable for refrigerators of make, VIDEOCON, GODREJ,KELVINATOR, SAMSUNG and any capacity (single/double door) etc complete all as specified and directed. Make & Size : As per sample | 12 | Each | |
| 36 | 36 | Supply only door handle suitable for refrigerators of make VIDEOCON,, GODREJ,KELVINATOR, SAMSUNG and any capacity (single/double door) etc complete all as specified and directed.\nMake & Size : As per sample | 10 | Each | |
| 37 | 37 | Supply only freezer with door assembly of make as approved by GE of size 165 upto 310 ltr capacity refrigerator(single/double door) complete all as directed.Make & Size : As per sample | 3 | Each | |
| 38 | 38 | Supply only bottom plate suppot Legs (size as per sample) suitable for refrigerators of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG and any capacity etc complete all as specified and directed. | 40 | Each | |
| 39 | 39 | Supply only door light switch (push button type) with lamp holder of make and size as directed complete all as directed. | 10 | Each | |
| 40 | 40 | Supply only electric bulb 15watt 250 volt AC or pin type make philips, Havells, Bajaj complete all as directed. | 26 | Each | |
| 41 | 41 | Supply only Glass cover for vegitable tray suitable for 165 upto 320 ltrs capacity of refrigerator(single/double door) complete all as directed.Make & Size : As per sample | 12 | Each | |
| 42 | 42 | Supply only fan motor for frost free Refrigerator of make VIDEOCON,, GODREJ, KELVINATOR, SAMSUNG, LG, WHIRLPOOL etc and any capacity complete all as directed. Make :-As Per Sample | 5 | Each | |
| 43 | 43 | Supply only frost heater suitable for frost free Reftigerator of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG,LG,,WHIRLPOOL etc and any capacity complete all as directed.Make: As per sample | 4 | Each | |
| 44 | 44 | Supply only bio metal switch suitable for frost free Refrigerator of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG,LG,,WHIRLPOOL etc and any capacity complete all as directed.Make: As per sample | 4 | Each | |
| 45 | 45 | Supply only ice cube tray for Refrigerator 165 upto 320 ltrs capacity complete all as directed by Engineer-in-charge.Make & Size: As per sample | 10 | Each | |
| 46 | 46 | Supply only vegitable basket for refrigerator of different capacity as directed by Engineer-in-charge.Make & Size:- As per sample | 10 | Each | |
| 47 | 47 | Supply only timer suitable for frost free Refrigerators of make VIDEOCON, GODREJ,KELVINATOR, SAMSUNG,LG,,WHIRLPOOL etc and any capacity complete all as directed.Make: As per sample | 3 | Each | |
| 48 | 48 | Supply only bottle rack of refrigerator door suitable for refrigerator 165 upto 320 ltr capacity and any make complete all as directed by Engineer-in-charge.Make & Size :- As per sample | 12 | Each | |
| 49 | 49 | Dismantling and taking down unserviceable condensor coil and S&F condensor coil with accessories suitable for regrigerator of any make and capacity including charging of refrigerant gas R-134A and leakage testing and proper working effect duly complete all as specified and directed.Make - as per sample | 2 | Each | |
| 50 | 50 | Dismantling and taking down unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor unit of Make Kelvinator, Kirlosker, Whirlpool, Godrej, LG,Samsung etc capacity 1/8, 1/6 TR for Referigerator of any make, any size with copmplete testing by nitrogen pressure and charging of gas R-134A upto required pressure and proper working effect complete of size 165/190 to 310/320 litres capacity. | 5 | Each | |
| 51 | 51 | Servicing of Deep Freezer Cap-200/300/310/320/340 ltrs complete cleaning of storage, cooling/condenser coils etc complete all as directed by Engineer-in-Charge..Note :- (i)The rate quoted for servicing shall be inclusive of attending complaints and keeping the deep freezer in working condition during the entire contract period and further for defects liability period.(ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item | 13 | Each Job | |
| 52 | 52 | Checking of leakage of refrigerent system of Deep Freezer of capacity 200/300/310/320/340 litrs by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing / welding of bottom leg suppots, testing and vaccumising the system and supply and filling of oil in required quantity complete all as specified and directed .\nNote :- Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item | 6 | Each Job | |
| 53 | 53 | Supply only Condensor fan Motor suitable for Deep freezer of any make and capacity complete all as specified and directed. :- \nMake & Capacity : As per sample | 2 | Each | |
| 54 | 54 | Supply only fan blade suitable for Deep freezer of any make and capacity complete all as specified and directed. :- Make & Size : As per sample | 3 | Each | |
| 55 | 55 | Disconnecting, dismantling and taking out defective /unserviceable sealed compressor unit and exchange with reconditioned sealed compressor unit suitable for deep freezer of any make/size and capacity with complete testing by nitrogen pressure and charging of gas R-134A upto required pressure and proper working effect duly complete all as specified and directed. | 2 | Each | |
| 56 | 56 | Painting of existing Deep Freezer of any description and any position and capacity with applying one coat of synthetic enameled paint (white or approved by Engr-in-charge) by spray machine including preparation of existing decorated surface of deep freezer including writing MES No/ SM No in capital letters of height not less than 20 mm on deep freezer body in MES pattern and style complete all as specified and directed. | 5 | Each Job | |
| 57 | 57 | Supplying and Charging of refrigerant gas (Make Mafron R-134A) including leakage testing of complete plant/equipment with nitrozen gas and repairing leakage portion complete all as specified and directed. | 90 | Kg | |
| 58 | 58 | Servicing of desert cooler in any position by, strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler complete all as directed by Engineer-in-Charge.Note :-The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item. | 96 | Each Job | |
| 59 | 59 | Taking down desert cooler from the site by disconnecting the electric and water connections and scrapping old paint, cleaning and necessary preparation of surfaces and painting of existing colour with one coat of anti corrosive paint internally and two coats of synthetic enamel paint externally on the surfaces including bottom surface of desert cooler by spray painting and writing MES No of the desert cooler in the pattern and style as approved by the Engineer-in-Charge with different tint / colour complete all as specified and as directed. | 45 | Each Job | |
| 60 | 60 | Supply only electric blower fan motor 1/5 HP 1400 RPM single shaft for desert cooler complete all as directed. Make: AUE/Crompton/Coolmaster/ Texmo | 28 | Each | |
| 61 | 61 | Supply only water lifting submersible pump 1/7 HP 1400 rpm for desert cooler complete all as directed.Make : Crompton / AUE / Khaitan/ Bajaj | 80 | Each | |
| 62 | 62 | Supply only wood wool pad, set of three, weight not less than 200gms of required size as approved suitable for various desert coolers panels including GI chicken wire mesh complete as per site and as directed by Engineer-in-charge.Size of wood wool pad :-As Per Sample | 96 | Each Set | |
| 63 | 63 | Supply only condensor 4 Mfd suitable for desert cooler complete all as directed.\nMake: Havells/Usha/Delcon/Epcos/Sycap | 55 | Each | |
| 64 | 64 | Supply only fan blade set for desert cooler of size 18\"/24\" dia complete all as directed.Make:-As Per Sample | 24 | Each | |
| 65 | 65 | Supply only switch controlling knob of any size and make complete all as directed. Make:-As Per Sample | 44 | Each | |
| 66 | 66 | PVC insulated and sheathed cable 3 core 1.5 sqmm stranded copper conductor fixed in reapair complete all as directed.. \nMake :-Plaza/Finolex/Havells/Polycab/Shalbh India | 90 | RM | |
| 67 | 67 | MS steel work for Desert cooler frame work,Cross arms,branching,supports,clamps,angles and back plates fabricated from structural steel sections including nuts,bolts,washers,welding,bending cold or hot ,drilling holes for bolts, in any shape or size as indicated or directed in repair and with including two coat of synthtic enamel paint over a coat of primer. Complete all as directed. | 80 | KG | |
| 68 | 68 | Servicing of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) complete cleaning of cooling /condenser coils, changing of air dust filter pads complete all as specified and directed by Engineer-in-Charge.Note :- The rate quoted for servicing shall be inclusive of attending complaints and keeping the Cold Storage Plant of 5 ton Cap in working condition during the entire contract period and further for defects liability period. | 6 | Each Job | |
| 69 | 69 | Checking of leakage of refrigerant system of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) by putting the nitrogen pressure , identifying the leaks / defects ,repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . Note :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2) is deemed to be included under the unit rate quoted by the contractor for this item | 6 | Each Job | |
| 70 | 70 | Copper tubing with insulation of sizes 5/8\" for Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) fixed in repair complete all as approved by GE and directed by Engineer-in-charge.Make:-WMC | 25 | RM | |
| 71 | 71 | Copper tubing with insulation of sizes 3/8\" for Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) fixed in repair complete all as approved by GE and directed by Engineer-in-charge.Make:-WMC | 20 | RM | |
| 72 | 72 | Insulation foam suitable for fixing with copper tubing 1/2\", 1/4\", 3/8\" and 5/8\" fixed in repair complete all as directed by Engineer-in-charge.Make:-Galaxy/Superlon | 145 | RM | |
| 73 | 73 | Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Shri Ram, Copeland , Kirloskar, Techumesh, and Carrier of one unit of Cold Storage Plant 5 ton Cap (2.5 TR x 2 Units) complete including testing of nitrogen gas pressure and charging of gas R-22/R - 404A upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. \n | 4 | Each | |
| 74 | 74 | Blower fan motor of one unit of Cold Storage Plant of 5 ton Cap (2.5 TR x 2 Units) including testing fixed in repair complte all as directed by Engineer-in-Charge.Make:- ISI Marked, as approved by Engineer-in-charge. | 5 | Each | |
| 75 | 75 | Single pole, 25 Amp contactor suitable for Cold Storage Plant 5 ton (2.5TR x 2 Units) capacity fixed in repair complete all as directed by Engineer-in -charge. Make: L&T/ABB/BCH/Seimens | 5 | Each | |
| 76 | 76 | Condensor fan blade set suitable for cold storage plant 2.5 Ton capacity of ISI marked as approved by GE fixed in repair.Make :-As per sample | 3 | Each | |
| 77 | 77 | Supply & charging of refrigerant Gas REFR ON (R-404A) to make up the required pressure complete all as specified and directed by Engineer-in-Charge. | 7.5 | Kg | |
| 78 | 78 | Air tight door rubber gasket suitable for Cold Storage Plant 5 ton Cap (2.5 TR x 2 Units) including testing fixed in repair complete all as directed by Engineer-in-Charge.Make & size :As Per Sample | 125 | RM | |
| 79 | 79 | Cut off panel of cooling system with senser and all accessories suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity fixed in repair complete all as specified and directed by Engineer-in-Charge. Make :-As Per Samle | 5 | Each | |
| 80 | 80 | Evaporating unit with all accessories suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity fixed in repair complete all as specified and directed by Engineer-in-Charge. Make :-As Per Samle | 3 | Each | |
| 81 | 81 | Condenser copper coil suitable for blue star cold storage plant 5 ton (2.5 X 2 units) capacity with all accessories and including charging of refrigerant gas R-22/R - 404A and leakage testing complete fixed in repair complete all as directed.Make :- As per sample | 2 | Each | |
| 82 | 82 | Dismantling and taking out the non-functional voltage stabilizer for General servicing and minor repairs AC 230 volts Single Phase 0.5 to 15 KVA cap. of any make by checking, tightening of electrical connection, replacement of all missing/worn out screws, indicating lamps, checking of electronic circuits to make it functional including replacement of minor defective parts complete all as specified and directed. Note :-The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item | 92 | Each Job | |
| 83 | 83 | Supply only transformer copper wound of voltage stabilizer AC, Single Phase, 230 volts of capacity 15 KVA of approved make. | 1 | Each | |
| 84 | 84 | All as per Item No 83 above but of capacity 5KVA -do- | 10 | Each | |
| 85 | 85 | All as per Item No 83 above but of capacity 4 KVA -do- | 9 | Each | |
| 86 | 86 | All as per Item No 83 above but of capacity 3 KVA -do- | 8 | Each | |
| 87 | 87 | All as per Item No 83 above but of capacity 2 KVA -do- | 7 | Each | |
| 88 | 88 | All as per Item No 83 above but of capacity 0.5/1 KVA -do- | 7 | Each | |
| 89 | 89 | Supply only electro mechanical type voltmeter 0 to 300 volts Single Phase , AC, 65 mm square/round type for stabilizer as per requirement complete all as specified & directed. Make – AE or equivalent approved. | 15 | Each | |
| 90 | 90 | Supply only relay 12/24 volts suitable for 1 -15 KVA voltage stabilizer AC, Single Phase, 230 volts of approved make | 19 | Each | |
| 91 | 91 | Supply only DC electronic circuit relay of capacity 24/12 volts stabilizer for 1 to 15 KVA complete of approved make all as specified & directed. | 16 | Each | |
| 92 | 92 | Supply only 3 way connector 230 volts 50 Hz AC, 32 Amp complete of approved make & of existing shape and size all as specified. | 18 | Each | |
| 93 | 93 | Supply only toggle switch 20/30 Amp two way of approved make all as specified and directed. | 32 | Each | |
| 94 | 94 | Supply only top plug 15 amp, 240 volts, ISI marked.Make:-Cona/Anchor/SSK | 41 | Each | |
| 95 | 95 | Supply only top plug 5 amp, 240 volts, ISI marked. Make:-Cona/Anchor/SSK | 35 | Each | |
| 96 | 96 | Preparation of old surface of voltage stabilizer by denting and rubbing and applying one coat of synthetic enamel paint by spray painting and writing MES No Complete all as specified and directed. | 25 | Each Job | |
| 97 | 97 | Plug top & socket with sheet metal enclosures single pole and neutral with & including one MCB, 240 Volts, single pole 32 Amp having breaking capacity 10 KA fixed in repair complete all as directed. Make : Legrand, Schneider, C&S\n\n | 24 | Each | |
| 98 | 98 | MCB SP 6 to 32 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed. \nMake:- L&T/Indoasian/Legrand Cat No-4085 87 to 4085 95 | 22 | Each | |
| 99 | 99 | MCB / Isolator SPN 40 to 63 Amps, 240 volts 'C' Curve 10 KA, including connection with suitable size copper lugs fixed in repair complete all as directed. \nMake:- L&T/ ABB/ Schneider/ C&S/Legrand Cat No-4086 18 to 4086 20 | 13 | Each | |
| 100 | 100 | Dismantling and taking out/down the non-functional Air conditioner window type of any description, any make and in any position, 1.5 TR/2 TR capacity, single phase, 50 Hz, strip opening, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts, painting the bottom with one coat of black synthetic enameled paint, replacement of the unserviceable and defective parts, brazing, reassembling and testing of the AC complete all as specified and directed by Engineer–in–charge. \nNote :-(i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item (ii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.(iii) The rate quoted for servicing shall be inclusive of attending complaints and keeping the AC in working condition during the entire contract period and further for defects liability period. | 16 | Each Job | |
| 101 | 101 | Checking of leakage of refrigerant system of window type AC of capacity 1.5/2.0 ton by putting the nitrogen pressure, identifying the leaks / defects, repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . \nNote :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), is deemed to be included under the unit rate quoted by the contractor for this item | 8 | Each Job | |
| 102 | 102 | Supply & charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge. | 85 | Kg | |
| 103 | 103 | Supply only starting capacitor 80-100 mfd suitable for 1.5/2 TR capacity Window/split type AC complete all as directed. Make: Havells/Usha/Delcon/Epcos/Sycap. | 22 | Each | |
| 104 | 104 | Supply only starting capacitor of capacity 100-120 mfd complete all as directed. \nMake: Havells/Usha/Delcon/Epcos/Sycap. | 13 | Each | |
| 105 | 105 | Supply only running capacitor 36 mfd, complete all as directed. Make: Havells/Usha/Delcon/Epcos/Sycap | 21 | Each | |
| 106 | 106 | Supply only running capacitor 45 mfd, complete all as directed. Make: Havells/Usha/Delcon/Epcos/Sycap | 29 | Each | |
| 107 | 107 | Supply only controlling knob selector switch, ISI mark complete all as directed.Make:-As Per Sample | 8 | Each | |
| 108 | 108 | Supply only electric condenser fan motor of split/window type AC capacity 1.5TR/2 TR AC , 220 Volts, Single phase. Make of Motor ;- GE /Crompton/or equivalent make as approved by GE. | 17 | Each | |
| 109 | 109 | Supply only front grill suitable for window type AC 1.5/2 TR cap of make Bluestar/Carrier/LG etc complete all as directed.Make:-As Per Sample | 7 | Each | |
| 110 | 110 | Supply only nylon/press jute filter suitable for 1.5 TR window AC complete all as specified and directed. Make & size :-As Per Sample | 16 | Each | |
| 111 | 111 | Supply only electric panel suitable for window type 1.5 /2TR AC units including making all electrical connections complete all as specified and directed by Engineer-in-Charge. Make:-As Per Sample | 5 | Each | |
| 112 | 112 | Supply only ventury made of thermo-coal insulation suitable for 1.5 TR/2TR capacity window type AC complete all as specified and directed by Engineer-in-Charge. (Make : Voltas / Blue Star / Carrier/LG/Videocon/Usha/Feeder Lloyd) | 6 | Each | |
| 113 | 113 | Supply only wiring Kit suitable for window type AC 1.5 to 2 TR cap complete all as specified & directed. Make:-As Per Sample | 7 | Each | |
| 114 | 114 | Supply only reverse cycle valve for heating system in window type /split type AC 1.5 / 2 Ton capacity with and including charging of refrigerant gas R-22 and leakage testing complete in position etc complete all as directed.Make : Renutrol/Pacific | 18 | Each | |
| 115 | 115 | Supply only thermostat switch suitable for 1.5 TR/2 TR capacity of window type AC complete all as specified and directed by Engineer-in-Charge. Make classic, indofoss, Annapurna. | 6 | Each | |
| 116 | 116 | Supply only condensor fan blade set for window / Split type AC 1.5 / 2 Ton capacity of ISI marked as approved by GE. Make:-As Per Sample | 22 | Each | |
| 117 | 117 | Supply only relay box type suitable for window/ Split type AC 1.5TR/2TR capacity complete all as directed by Engineer-in charge. Make Classic/indofoss/Annapurna/ SriRam/Micro Tech/L&T | 16 | Each | |
| 118 | 118 | PVC insulated and sheathed cable 3 core 4.0 sqmm stranded copper conductor fixed in repair complete all as spcified and directed. \nMake :-Plaza/Finolex/Havells/Polycab/Shalbh India | 180 | RM | |
| 119 | 119 | Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Kirloskar, Voltas, Carrier, Bluestar,LG,Samsung etc. for Window type AC 1.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. | 4 | Each | |
| 120 | 120 | Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor of Make Kirloskar, Voltas, Carrier, Bluestar,LG,Samsung etc. for Window type AC 2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. | 2 | Each | |
| 121 | 121 | Copper tubing with insulation of size 3/8\" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repair complete all as directed. Make: WMC | 65 | RM | |
| 122 | 122 | Copper tubing with insulation of size 5/8\" special annealed pressure copper purity min 99.9% and making flaring at both ends for connections including brass nut and testing fixed in repaircomplete all as directed. Make: WMC | 65 | RM | |
| 123 | 123 | Prepration of surfaces and applying two coats of Matt finish synthetic enamal Asian/Burger paint anti rust /anti crossive to any type of Window AC complete all as specified and dierected | 7 | Each | |
| 124 | 124 | Condenser copper coil suitable for window type /split type AC 1.5 / 2 Ton capacity fixed in repair with and including charging of refrigerant gas R-22 and leakage testing complete all as directed.Make :- As per sample | 3 | Each | |
| 125 | 125 | Taking out existing defective window/Split AC electric motor of 930 RPM, 1/8,1/5 HP 220 volts single phase strip opening for rewinding, removing for rewinding to & from to workshop as approved by Engineer-in-Charge, rewinding with appropriate size copper super enameled wire (Make : Atlas /Finolex /Devi Dayal ) as approved by the engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop to the entire satisfaction of Engineer-in-charge and transportation & fixing the motor at site including necessary connection & testing at site complete all as specified and directed by Engineer-in-Charge. | 8 | Each | |
| 126 | 126 | Dismantling and taking out the existing Air conditioner Split type of any description any capacity, any make and in any position, both indoor and outdoor unit single phase, strip opening , cleaning and servicing of the AC with using caustic soda/detergent solution, cleaning of suction air filter and coil of indoor unit and brazing the discharge and suction line, reassembling, fixing and testing of the AC complete all as specified and directed by Engineer-in-Charge. \nNOTE:- (i) The servicing of one split AC (one indoor unit + one outdoor unit) will be measured as one job.\n(ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item \n(iii) Any minor complaints such as lekage of water, abnormal noise and any electric loose connection etc raised by user after carrying out servicing shall be rectified by the contractor without any extra cost to the Govt.\n(iv) The rate quoted for servicing shall be inclusive of attending complaints and keeping the AC in working condition during the entire contract period and further forr defects liability period. | 40 | Each Job | |
| 127 | 127 | Checking of leakage of refrigerant system of split type AC of capacity 1.5/2.0 ton by putting the nitrogen pressure, identifying the leaks / defects, repairing the same by brazing and testing and vacuumising the system and supply and filling of oil in required quantity complete all as specified and directed . \nNote :-Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), is deemed to be included under the unit rate quoted by the contractor for this item | 25 | Each Job | |
| 128 | 128 | Supply only single pole, 25Amp contactor suitable for split AC 1.5/2 TR capacity complete all as directed by Engineer-in-charge. Make: L&T/ABB/BCH/Seimens | 19 | Each | |
| 129 | 129 | Supply only mild steel angle iron stand factory made suitable for out door unit for 1.5/2 TR split AC complete all as directed by Engineer-in-charge.Make shape & size as per existing :-As Per Sample | 8 | Each | |
| 130 | 130 | Supply only remote for senser kit suitable for 1.5/2 TR capacity Split type AC of make Voltas, LG, Carrier AC's complete all as directed by Engineer-in-charge.Make :-As Per Sample | 12 | Each | |
| 131 | 131 | Supply only blower fan motor single phase 220/230 volts 1400 RPM suitable for 1.5TR/2TR Split type AC complete all as directed.\nMake: AUE/Crompton/Coolmaster/ Texmo | 12 | Each | |
| 132 | 132 | Supply only PCB plate complete with connections suitable for Split type AC 1.5TR/2TR single phase capacity complete all as specified and directed by Engineer-in-Charge \nMake: arrier/Hitachi/LG/samsung/Lloyed/Usha/Vediocone | 10 | Each | |
| 133 | 133 | Insulation for copper tube of size 3/8” or 5/8” fixed in repair all as directed by Engineer-in-Charge (Make : Galaxy/ Superlon) | 250 | RM | |
| 134 | 134 | PVC flexible Pipe 25mm/40mm/50mm dia size over insulated copper tube 3/8” or 5/8”,with necessary packing tape 50mm wide for protection fixed in repair complete all as specified and directed by Engineer-in-Charge. (Make : Rajdoot ) | 87 | RM | |
| 135 | 135 | 1.00 mm thick plain galvanised mild steel sheet for covering of split AC out door and similar work cut to size, holes punched including round headed screw clouts, Nails, or rivets and fixed to wooden or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up mitred angles etc as required fixed in repair complete all as specified and directed by Engineer-In-Charge. | 6 | Sqm | |
| 136 | 136 | Shifting and fixing split AC cap- 1.0/ 1.5 / 2.0 TR including cutting for hole on wall and making good of disturbed surface with matching existing finishes complete all as directed by Engineer-in-charge. | 8 | Each Job | |
| 137 | 137 | Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Kirloskar, Voltas, Carrier, LG,samsung,Videocon,Loyed etc. for Split type AC 1.5 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. \n | 4 | Each | |
| 138 | 138 | Dismantling and taking out unserviciable sealed compressor unit and exchange with company reconditioned sealed compressor. Make Kirloskar, Voltas, Carrier, LG,samsung,Videocon,Loyed etc. for Split type AC 2 TR capacity complete including testing of nitrogen gas pressure and charging of gas R-22 upto required pressure and proper working effect to the satisfaction of Engineer-in-Charge. | 2 | Each | |
| 139 | 139 | Prepration of surfaces and applying two coats of Mat finish synthetic enamal Asian/Burger paint anti rust /anti crossive to Split AC (Indoor + out door) complete all as specified and dierected by the Engineer -in-charge. | 10 | Each Job | |
| 140 | 140 | PVC wire insulated, unsheathed copper conductor single core, 04 sqmm 1100 Volts grade, multi stranded, FRLS flexible wire cable fixed in repair \nMake -HPL/Havells/Finolex/Relison. | 100 | RM | |
| 141 | 141 | Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 4 Sq mm size with multi stranded copper conductor drawing into 20 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed1X4 Sq mm cable(Green Colour) with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all as specified and directed.\nMake of wire : Finolex, Plaza, Havells, Polycab, Gloster, Universal, Grandlay, Make of conduit : Finolex/Ess Ess Kay/ICL \nNOTE: (i) Two run of 4 sqmm single core PVC cable with one run of1X 4 sqmm (Green Colour) cable as earth conductor & condiut shall be measured as one unit/RM.\n(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. | 120 | RM | |
| 142 | 142 | Sub main wiring with two single core PVC insulated unsheathed FRLS cable 1100 Volt grade, 6 Sq mm size with multi stranded copper conductor drawing into 20 mm dia rigid PVC conduit in surface/concealed as required including one run single core PVC insulated unsheathed 6 Sq mm cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking down old unserviceable submain wiring etc complete all as specified and directed.\nMake of wire : Finolex, Plaza, Havells, Polycab, Gloster, Universal, Grandlay, Make of conduit : Finolex/Ess Ess Kay/ICL \nNOTE: (i) Two run of 6 sqmm single core PVC cable with one run of 6 sqmm (Green Colour wire) as earth conductor & condiut shall be measured as one unit/RM.\n(ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. | 60 | RM | |
| 143 | 143 | Servicing spin dryer unit including cleaning of blower fan,fan motor,round type heating system etc. complete all as specified and directed . Note :-(i) The rate quoted for servicing shall be inclusive of attending complaints and keeping the spin dryer in working condition during the entire contract period and further for defects liability period. (ii) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item | 7 | Each Job | |
| 144 | 144 | Supply only blower fan blade set suitable for spin dryer machine of ISI marked as approved by GE. Make & Size :-As Per Sample | 5 | Each | |
| 145 | 145 | Supply only heater element set suitable for spin dryer machine of ISI marked as approved by GE.\nMake & Size :- As Per Sample | 6 | Each | |
| 146 | 146 | Supply only Blower fan motor single phase 220/230 volts 1400 RPM suitable for spin dryer machine complete all as directed.\nMake & Capacity :- As Per Sample | 5 | Each | |
| 147 | 147 | Switch piano, flush type, single pole one way, 15 Amp fixed in repair complete all as directed. Make:- Anchor/Legrand/Havells/C&S. | 16 | Each | |
| 148 | 148 | Socket outlet, multipurpose, 2 in 1 5 pin, 15 Amp fixed in repair complete all as directed. Make:- Anchor/Legrand/Havells/C&S. | 16 | Each | |
| 149 | 149 | Supply & charging of DIFLUORMETHANE R-32 refrigerent gas to make up the required pressure complete all as specified and directed by Engineer-in-Charge.\n | 5 | Kg | |
| 150 | Total in Figures |