| 1 | 1 | Laying and Jointing PVC Pipe. Heading | BI01010001010000000000000515BI0100001112 | | |
|---|
| 2 | 1.01 | Relaying/ Replacement of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering.\n(a) Upto 35 sqmm. | BI01010001010000000000000515BI0100001113 | 720 | mtr |
|---|
| 3 | 1.02 | (b) Above 35 sqmm and upto 95 sqmm | BI01010001010000000000000515BI0100001114 | 500 | mtr |
|---|
| 4 | 1.03 | (c) Above 95 sqmm and upto 185 sqmm | BI01010001010000000000000515BI0100001115 | 1500 | mtr |
|---|
| 5 | 2.01 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.\n(a)Upto 35 sq. mm | BI01010001010000000000000515BI0100001116 | 210 | mtr |
|---|
| 6 | 2.02 | (b)Above 35 sq. mm and upto 95 sq. mm | BI01010001010000000000000515BI0100001152 | 360 | mtr |
|---|
| 7 | 2.03 | (c)Above 95 sq. mm and upto 185 sq. mm | BI01010001010000000000000515BI0100001118 | 100 | mtr |
|---|
| 8 | 3.01 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n(a) 3.5 x 35 sqmm. | BI01010001010000000000000515BI0100001119 | 5 | Nos |
|---|
| 9 | 3.02 | (b) 3.5 x 50 sqmm. | BI01010001010000000000000515BI0100001120 | 3 | Nos |
|---|
| 10 | 3.03 | (c) 3.5 x 120 sqmm. | BI01010001010000000000000515BI0100001121 | 5 | Nos |
|---|
| 11 | 3.04 | (d) 3.5 x 185 sqmm. | BI01010001010000000000000515BI0100001122 | 3 | Nos |
|---|
| 12 | 4.01 | Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.\n(a) 3.5 x 35 sqmm. | BI01010001010000000000000515BI0100001123 | 18 | Nos |
|---|
| 13 | 4.02 | (b) 3.5 x 50 sqmm. | BI01010001010000000000000515BI0100001124 | 5 | Nos |
|---|
| 14 | 4.03 | (c) 3.5 x 120 sqmm. | BI01010001010000000000000515BI0100001125 | 5 | Nos |
|---|
| 15 | 4.04 | (d) 3.5 x 185 sqmm. | BI01010001010000000000000515BI0100001126 | 4 | Nos |
|---|
| 16 | 5.01 | S/ITC of outdoor type joint/ inspection box made out of 14 SWG CRCA sheet of size 600 mm X 450 mm X 300 mm having 200 amps, 04 nos insulated aluminium bus bars and including angle iron frame of size 450 mm x 300 mm with 750 mm long legs made out of 40 mm x 40 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation(1:3:6), arrange ment for incoming/outgoing cabling/ cable termination, inbuilt locking arrragement ,interconnection i/c suitable size nut & bolts with washer, with danger plate at the outer facing surface of joint/ inspection box (feeder pillar), with top cover and breather etc as required. | BI01010001010000000000000515BI0100001127 | 6 | each |
|---|