Repair/Maintenance Of Summer Appliances With Connected Works At Af Stn Sirsa, GE (AF) SIRSA-Haryana

Military Engineer Services-MES has published Repair/Maintenance Of Summer Appliances With Connected Works At Af Stn Sirsa. Submission Date for this Tender is 03-04-2020. Air Conditioner Tenders in GE (AF) SIRSA Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

23957353
Corrigendum : Repair/Maintenance Of Summer Appliances With Connected Works At Af Stn Sirsa
National Competitive Bid
Indian
Haryana
GE (AF) SIRSA
03-04-2020

Tender Details

Repair / Maintenance Of Summer Appliances With Connected Works At Af Stn Sirsa-Air Conditioner ( Window Type ) , M&L Repairing And Maintenance Of Ac 1 . 5 / 2 . 0 Ton Window Type At Different Location By Taking Out / Down From Existing Position / Location And Re-Installation After Overhauling , Washing And Cleaning Cooling Coil And Condenser Along With Fittings First With Air Blower , Then With Spraying With Coil Cleaning Chemical Of Best Quality In Coil And Condenser , Then Washing With Plain Fresh Water Until All Chemicals Are Removed And Testing , Complete All As Specified And As Directed . , S&F Blower And Condenser Fan Blade With Allen Nuts ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Motor ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: American Universal / Botliboi , S&F Running Capacitor 36+6 Mfd Suitable For Ac 1 . 5 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 45+6 Mfd Suitable For Ac 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 80 / 100 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Selector Switch Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Of Any Make Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Thermostatic Switch With Knob Plate And Screws Suitable For Ac 1 . 0 / 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , M&L Sealed Compressor Unit Suitable For Ac 1 . 5 Ton Window Type Including Brazing Of Copper Pipe , Cleaning Of Refrigerant System Of Ac , Replacement Of Strainer , Rubber Pads For Foundation , Nuts And Bolts , Etc . And Testing Including Taking Out / Down Unserviceable Sealed Compressor And Connected Items , Complete All As Specified And As Directed . Make: Copeland / Kirloskar / Tacemesh Note: ( A ) Dismantling And Reinstallation Of Outdoor Unit Shall Deem To Be Included In Quoted Unit Rate . ( B ) Transporation Charges Shall Deem To Be Included In Quoted Unit Rate . ( C ) Charging Of Refrigerant Shall Be Measured Separately , M&L Sealed Compressor Unit Suitable For Ac 2 . 0 Ton Window Type Including Brazing Of Copper Pipe , Cleaning Of Refrigerant System Of Ac , Replacement Of Strainer , Rubber Pads For Foundation , Nuts And Bolts , Etc . And Testing Including Taking Out / Down Unserviceable Sealed Compressor And Connected Items , Complete All As Specified And As Directed . Make: Copeland / Kirloskar / Tacemesh Note: ( A ) Dismantling And Reinstallation Of Outdoor Unit Shall Deem To Be Included In Quoted Unit Rate . ( B ) Transporation Charges Shall Deem To Be Included In Quoted Unit Rate . ( C ) Charging Of Refrigerant Shall Be Measured Separately , M&L Taking Out Blower Motor From Ac 1 . 5 / 2 . 0 Ton Window Type , 230 Volt , 50 Cycles , Removing Burnt Winding Wire , Rewinding The Blower Motor With Super Enamelled Copper Winding Wire Of Suitable Size And Providing Insulation Along With Insertion Of Superior Type Of Insulating Materials , Binding , Varnishing And Drying Well After Varnishing , Replacement Of Shaft , Gun Metal Bushes And Rubber Bushes For Blower Motor , Testing On Load After Fixing , Complete All As Specified And As Directed . , M&L Cleaning Gas System With Suitable Chemical , Charging Of Refrigerant , Preventing Of Leakage In The System , Providing Refrigerant With Anti-Moist Substance And Strainer , Copper Capillary Including Replacement Of Filter And Air Filter Of Ac 1 . 5 / 2 . 0 Ton Window Type , Testing On Completion , Complete All As Specified And As Directed . , Air Conditioner ( Split Type ) , M&L Repairing And Maintenance Of Ac 1 . 5 / 2 . 0 Ton Split Type At Different Location By , Washing And Cleaning Cooling Coil And Condenser Along With Fittings First With Air Blower , Then With Spraying With Coil Cleaning Chemical Of Best Quality In Coil And Condenser , Then Washing With Plain Fresh Water Until All Chemicals Are Removed And Testing , Complete All As Specified And As Directed . , S&F In Repairs Auto Circuit Plate With Remote 220 Volt , 50Hz Suitable For Ac Of Any Type ( Window / Split ) Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Fan Blade With Allen Nuts ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Spilt Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Motor ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: American Universal / Botliboi , S&F Coil For Outdoor / Indoor Unit Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 3 / 8 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 5 / 8 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 4 / 16 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 1 / 2 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Insulation Sleeve Type Of Best Quality For Copper Tubing For Suction / Discharge Pipe Any Size Including Taking Out / Down Unserviceable One , Complete All As Specified . , S&F Plastic Pvc Pipe Of 25Mm Bore , Isi Mark As Drain Pipe Of Acs Split Type , Fixed To Wall With Necessary Clamps , Screws , Etc . Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Running Capacitor 50+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 36+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 100 / 120 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 80 / 100 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 45+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 2 . 5 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Relay Assembly With Cover & Clip Suitable For Ac 1 . 5 / 2 . 0 Ton Capacity , Split Type Including Taking Out / Down Unserviceable One , Complete All As S

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Mar-2020 DATE AMENDMENT Date 03-04-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 40000.0 /-
Tender Value
Refer document

BOQ Items

NAME OF WORK : REPAIR/MAINT OF SUMMER APPLIANCES WITH CONNECTED CONNECTED WORKS AT AF STN SIRSA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 AIR CONDITIONER (WINDOW TYPE) BI01010001010000000000000515BI0100001113
2 1.01 M&L Repairing and Maintenance of AC 1.5/2.0 Ton Window type at different location by taking out/down from existing position/location and re-installation after Overhauling, Washing and Cleaning Cooling Coil and Condenser along with Fittings First with Air Blower, then with spraying with coil cleaning chemical of best quality in Coil and Condenser, then washing with Plain Fresh Water until all Chemicals are removed and Testing, complete all as specified and as directed. BI01010001010000000000000515BI0100001114 18 EACH JOB
3 1.02 S&F Blower and Condenser Fan Blade with Allen Nuts (as approved) suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001115 1 EACH
4 1.03 S&F Blower Motor (as approved) suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: AMERICAN UNIVERSAL/BOTLIBOI BI01010001010000000000000515BI0100001116 2 EACH
5 1.04 S&F running capacitor 36+6 mfd suitable for AC 1.5 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001117 8 EACH
6 1.05 S&F running capacitor 45+6 mfd suitable for AC 2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001118 4 EACH
7 1.06 S&F starting capacitor 80/100 mfd suitable for AC 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001119 4 EACH
8 1.07 S&F Selector Switch suitable for AC 1.5/2.0 Ton Window type of any Make including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001120 2 EACH
9 1.08 S&F Thermostatic Switch with Knob Plate and Screws suitable for AC 1.0/ 1.5/2.0 Ton Window type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001121 2 EACH
10 1.09 M&L Sealed Compressor Unit suitable for AC 1.5 Ton Window type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing including taking out/ down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH\nNote: \n(a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.\n(b) Transporation Charges shall deem to be included in Quoted Unit Rate.\n(c) Charging of refrigerant shall be measured separately BI01010001010000000000000515BI0100001122 2 EACH JOB
11 1.1 M&L Sealed Compressor Unit suitable for AC 2.0 Ton Window type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing including taking out/ down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH\nNote:\n(a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.\n(b) Transporation Charges shall deem to be included in Quoted Unit Rate.\n(c) Charging of refrigerant shall be measured separately\n BI01010001010000000000000515BI0100001123 1 EACH JOB
12 1.11 M&L Taking out Blower Motor from AC 1.5/2.0 Ton Window type, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of insulating materials, binding, varnishing and drying well after varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed. BI01010001010000000000000515BI0100001124 2 EACH JOB
13 1.12 M&L Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter and Air Filter of AC 1.5/ 2.0 Ton Window type, testing on completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001125 10 EACH JOB
14 2 AIR CONDITIONER (SPLIT TYPE) BI01010001010000000000000515BI0100001126
15 2.01 M&L Repairing and Maintenance of AC 1.5/2.0 Ton Split type at different location by, Washing and Cleaning Cooling Coil and Condenser along with Fittings First with Air Blower, then with Spraying with coil cleaning chemical of best quality in Coil and Condenser, then Washing with Plain Fresh Water until all Chemicals are removed and Testing, complete all as specified and as directed. BI01010001010000000000000515BI0100001127 230 EACH JOB
16 2.02 S&F in repairs auto Circuit Plate with Remote 220 Volt, 50Hz suitable for AC of any type (Window/Split) including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001128 10 EACH JOB
17 2.03 S&F Blower Fan Blade with Allen Nuts (as approved) suitable for AC 1.5/2.0 Ton Spilt type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001129 10 EACH
18 2.04 S&F Blower Motor (as approved) suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: AMERICAN UNIVERSAL/BOTLIBOI BI01010001010000000000000515BI0100001130 30 EACH
19 2.05 S&F Coil for Outdoor/Indoor Unit suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001131 2 EACH
20 2.06 S&F Copper Tubing of size 3/8" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001132 25 RM
21 2.07 S&F Copper Tubing of size 5/8" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001133 50 RM
22 2.08 S&F Copper Tubing of size 4/16" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001134 50 RM
23 2.09 S&F Copper Tubing of size 1/2" suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001135 50 RM
24 2.1 S&F Insulation Sleeve type of Best quality for Copper Tubing for Suction/ Discharge Pipe any size including taking out/down unserviceable one, complete all as specified. BI01010001010000000000000515BI0100001136 175 RM
25 2.11 S&F Plastic PVC Pipe of 25mm bore, ISI mark as Drain Pipe of ACs Split type, fixed to Wall with necessary Clamps, Screws, etc. including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001137 50 RM
26 2.12 S&F running capacitor 50+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001138 40 EACH
27 2.13 S&F running capacitor 36+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001139 50 EACH
28 2.14 S&F starting capacitor 100/120 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001140 50 EACH
29 2.15 S&F starting capacitor 80/100 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001141 50 EACH
30 2.16 S&F running capacitor 45+6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001142 50 EACH
31 2.17 S&F running capacitor 6 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001143 25 EACH
32 2.18 S&F running capacitor 2.5 mfd suitable for AC 1.5/2.0 Ton Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001144 25 EACH
33 2.19 S&F Starting Relay Assembly with Cover & Clip suitable for AC 1.5/ 2.0 Ton capacity, Split type including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL BI01010001010000000000000515BI0100001145 20 EACH
34 2.2 M&L Sealed Compressor Unit suitable for AC 1.5 Ton Split type including brazing of Copper Pipe, cleaning of Refrigerant System of AC, and Compressor Oil, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and testing on completion including taking out/down unserviceable Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH\nNOTE :-\n(a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.\n(b) Transporation Charges shall deem to be included in Quoted Unit Rate.\n(c) Charging of refrigerant shall be measured seperately BI01010001010000000000000515BI0100001146 25 EACH JOB
35 2.21 M&L Sealed Compressor Unit suitable for AC 2.0 Ton Split type including brazing of Copper Pipe, cleaning of Refrigerant System of AC and Compressor Oil, replacement of Strainer, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/ down unserviceable Sealed Compressor and Connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH\nNOTE :-\n(a) Dismantling and reinstallation of outdoor unit shall deem to be included in Quoted Unit Rate.\n(b) Transporation Charges shall deem to be included in Quoted Unit Rate.\n(c) Charging of refrigerant shall be measured seperately BI01010001010000000000000515BI0100001147 20 EACH JOB
36 2.22 M&L Taking out Blower Motor from AC 1.5/2.0 Ton Split type, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of insulating materials, binding, varnishing and drying well after varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, Testing on Load after fixing, complete all as specified and as directed. BI01010001010000000000000515BI0100001148 15 EACH JOB
37 2.23 Dismantling existing AC 1.5/2.0 Ton Split type including Outdoor and Indoor Unit & reinstallation of Compressor Unit of AC 1.5/2.0 Ton Split type fixing of Air Conditioner on wall with Mild Steel Stand wherever required, providing connection of Copper Pipes of Compressor/Air Conditioner Unit the Pipe connection should be leak proof including necessary brazing of Pipes required, providing proper insulation of Copper Pipes as per requirement Installation of Voltage Stabilizer, making connections of Electric Cable of Compressor with Air Conditioner and further to Voltage Stabilizer and Power Point including Provision of Extra quantity of Flexible Copper Conductor Cable 3 Core 1100 volts of size 40/0.0076 and Top Plug 15 Amp, complete all as specified and as directed. \nNOTE :- \n(a) Refilling of gas shall be measured separately. BI01010001010000000000000515BI0100001149 10 EACH JOB
38 2.24 M&L Cleaning Gas System with suitable chemical, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary of AC 1.5/ 2.0 Ton Split type, Testing on Completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001150 120 EACH JOB
39 3 DESERT COOLER BI01010001010000000000000515BI0100001151
40 3.01 S&F Fan Leaf of best quality suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001152 90 EACH
41 3.02 S&F Front Grill Double Partition type of 20 SWG, best quality (as approved) of suitable size for Desert Cooler providing making Electric Connection to all Accessories as required including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001153 110 EACH
42 3.03 S&F Motor Kit suitable for Desert Cooler, Copper wounded complete and One Set of Lugs for mounting body including taking out/ down unserviceable one, complete all as specified and as directed. Make: CG/KHAITAN/Blueline BI01010001010000000000000515BI0100001154 90 EACH
43 3.04 S&F Plastic PVC Distributor suitable for Desert Cooler heavy duty 15mm with Elbow, Tee, etc. fixed with Bolts, Nut & Washers including taking out/down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001155 210 EACH
44 3.05 S&F Plastic PVC Pipe of 15mm bore suitable for Desert Cooler, heavy duty, ISI mark including taking out/down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001156 420 RM
45 3.06 S&F Running Capacitor 4 mfd suitable for Blower Motor of Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001157 70 EACH
46 3.07 S&F Selector Switch suitable for Desert Cooler of any Make and size including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001158 120 EACH
47 3.08 S&F Submersible Water Pump suitable for Desert Cooler including taking out/ down unserviceable one, complete all as specified and as directed. Make: KHAITAN/ORIENT/LITTLE PUMP BI01010001010000000000000515BI0100001159 180 EACH
48 3.09 S&F Plug Top, 3 Pin, 5/6 Amp including taking out/ down unserviceable one, complete all as specified and as directed. Make: ANCHOR/PLAZA/HAVELLS BI01010001010000000000000515BI0100001160 180 EACH
49 3.1 S&F PVC Round Flexible 3 Core Copper Connection Lead of size 23/0.0076, including taking out/ down unserviceable one, complete all as specified and as directed. Make: EMPIRE/PLAZA BI01010001010000000000000515BI0100001161 450 RM
50 3.11 M&L Mild Steel Desert Cooler Body of 20 SWG Powder Coated with 03 Nos Side Shutters of 22 SWG, Noise Pollution Control complete Body suitable for Air Flow capacity of 5000 Cum of large body including taking out/ down unserviceable one, complete all as specified and as directed. Make: BLUE LINE/CLARION/ELECTROMECH BI01010001010000000000000515BI0100001162 90 EACH
51 3.12 M&L Taking out Fan Motor from Desert Cooler any size and Make, 230 Volts, 50 Cycles, removing burnt Winding Wire, rewinding the Motor with super enamelled Copper Winding Wire of suitable size and providing insulation along with insertion of superior type of Insulating Materials, binding, Varnishing and drying well after Varnishing, replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, testing on load after fixing, complete all as specified and as directed. BI01010001010000000000000515BI0100001163 55 EACH JOB
52 3.13 S&F Wood Wool Pad (as approved) suitable for Desert Cooler, heavy duty and best quality including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001164 690 EACH
53 3.14 M&L preparing old surfaces of Desert Cooler Body by descaling, rubbing, brushing, cleaning and applying two coats of Synthetic Enamel Paint (as approved) with Spray Gun Machine and Tank with Black Bituminous Paint from Inside Tank, complete all as specified and as directed. BI01010001010000000000000515BI0100001165 200 EACH JOB
54 4 WATER COOLER BI01010001010000000000000515BI0100001166
55 4.01 S&F Fan Motor 1/35 HP complete with Blades suitable for Water Cooler of any capacity including taking out/down unserviceable one, complete all as specified and as directed. Make: AMERICAN UNIVERSAL/BOTLIBOI BI01010001010000000000000515BI0100001167 1 EACH
56 4.02 S&F Over Load Protector with Clips suitable for Water Cooler including taking out/down unserviceable one, complete all as specified and as directed. Make: SHARIRAM/RANUTROL BI01010001010000000000000515BI0100001168 3 EACH
57 4.03 S&F Running Capacitor 36 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001169 2 EACH
58 4.04 S&F Running Capacitor 15 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001170 2 EACH
59 4.05 S&F Starting Capacitor 80/100 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001171 2 EACH
60 4.06 S&F Starting Capacitor 40/60 mfd suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: EPCOS/HAVELLS/SHARDA BI01010001010000000000000515BI0100001172 1 EACH
61 4.07 S&F Starting Relay Assembly with Cover & Clip suitable for Water Cooler of any capacity, including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL BI01010001010000000000000515BI0100001173 2 EACH
62 4.08 S&F Self Closing Tap Brass Chromium plated 15mm suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. \n BI01010001010000000000000515BI0100001174 2 EACH
63 4.09 S&F Thermostatic Switch with Knob Plate and Screws suitable for Water Cooler of any capacity including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL BI01010001010000000000000515BI0100001175 2 EACH
64 4.1 M&L Sealed Compressor Unit of capacity 1.0 Ton suitable for Water Cooler 40 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH BI01010001010000000000000515BI0100001176 1 EACH JOB
65 4.11 M&L Sealed Compressor Unit of capacity 1.5 Ton suitable for Water Cooler 150 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Strainer, Capillary, Rubber Pads for Foundation, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: COPELAND/KIRLOSKAR/TACEMESH BI01010001010000000000000515BI0100001177 1 EACH JOB
66 4.12 M&L Taking out Blower Motor of Water Cooler of any capacity, 230 Volt, 50 Cycles, removing burnt Winding Wire, rewinding the Blower Motor with Super Enamelled Copper Winding Wire of suitable size and providing Insulation along with insertion of Superior type of Insulating Materials, Binding, Varnishing and Drying well after Varnishing, Replacement of Shaft, Gun Metal Bushes and Rubber Bushes for Blower Motor, Testing on Load after fixing, complete all as specified and as directed. BI01010001010000000000000515BI0100001178 1 EACH JOB
67 4.13 M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 40 Litre, Testing on Completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001179 1 EACH JOB
68 4.14 M&L Cleaning Gas System charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Water Cooler 150 Litre 1.0 Ton, Testing on Completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001180 1 EACH JOB
69 5 REFRIGERATOR BI01010001010000000000000515BI0100001181
70 5.01 S&F Starting Relay Assembly suitable for Refrigerator 170 Litre, including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL BI01010001010000000000000515BI0100001182 2 EACH JOB
71 5.02 S&F Starting Relay Assembly suitable for Refrigerator 286/310/315 Litre, including taking out/ down unserviceable one, complete all as specified and as directed. Make: INDFOS/RANUTROL BI01010001010000000000000515BI0100001183 2 EACH JOB
72 5.03 S&F over load protector suitable for Refrigerator 170 Litre, including taking out/ down unserviceable one, complete all as specified and as directed. Make: SHARIRAM/RANUTROL BI01010001010000000000000515BI0100001184 1 EACH
73 5.04 S&F over load protector suitable for Refrigerator 286/310/315 Litre, including taking out/ down unserviceable one, complete all as specified and as directed. Make: SHARIRAM/RANUTROL BI01010001010000000000000515BI0100001185 1 EACH
74 5.05 S&F Thermostatic Switch suitable for refrigerator of any description including taking out/ down unserviceable one, complete all as specified and as directed. BI01010001010000000000000515BI0100001186 2 EACH
75 5.06 M&L Sealed Compressor suitable for Refrigerator 120 to 170 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and connected Items, complete all as specified and as directed. Make: VOLTAS/KELVINATOR/TACEMESH\nNOTE : Transportation Charges shall deem to be included in Quoted Unit Rate. BI01010001010000000000000515BI0100001187 1 EACH JOB
76 5.07 M&L Sealed Compressor suitable for Refrigerator 286/310/315 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. Make: VOLTAS/KELVINATOR/TACEMESH\nNOTE : Transportation Charges shall deem to be included in Quoted Unit Rate. BI01010001010000000000000515BI0100001188 1 EACH JOB
77 5.08 M&L Cleaning Gas System with suitable chemical, charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 120 to 170 Litre, Testing on Completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001189 2 EACH JOB
78 5.09 M&L Cleaning Gas System with suitable chemical, Charging of Refrigerant, preventing of leakage in the System, providing Refrigerant with anti-moist substance and Strainer, Copper Capillary including replacement of Filter of Refrigerator 286/310/315 Litre, Testing on Completion, complete all as specified and as directed. BI01010001010000000000000515BI0100001190 1 EACH JOB
79 6 DEEP FREEZER BI01010001010000000000000515BI0100001191
80 6.01 M&L Sealed Compressor Unit suitable for Deep Freezer 400/500 Litre including brazing of Copper Pipe, cleaning of Refrigerant System, Charging of Refrigerant and Compressor Oil, Replacement of Foundation Rubber Bushes, Nuts and Bolts, etc. and Testing on Completion including taking out/down defective/burnt Sealed Compressor and Connected Items, complete all as specified and as directed. Make: VOLTAS/KELVINATOR/TACEMESH/KIRLOSKAR/GODREJ\nNOTE : Transportation Charges shall deem to be included in Quoted Unit Rate. BI01010001010000000000000515BI0100001192 1 EACH JOB
81 7 VOLTAGE STABILIZER BI01010001010000000000000515BI0100001193
82 7.01 M&L Repairing Voltage Stabilizer 4.0/5.0 KVA of any Make, Repairing/ Replacement of whichever of the following defective Accessories required:-\n(a) Relays \n(b) Repair/Rewinding of Transformer with Copper Coil \n(c) Circuit Plate \n(d) Digital Volt Meter \n(e) Indicator and Switches. BI01010001010000000000000515BI0100001194 8 EACH JOB
83 7.02 Supply, Installation Electronic Voltage Stabilizer for multi-protection Advance Technology with Transformer Single Phase Naturally Air Cooled Indoor type Wall mounted and designed for Input variation 150 Volt to 290 Volt with Output Voltage stabilized at 230 Volt with accuracy of (+) 2.5% and of capacity 4.0 KVA, complete all as specified and as directed. Make: V-GARD/VOLINA/MICROTEK BI01010001010000000000000515BI0100001195 5 EACH
84 8 MISC ITEMS BI01010001010000000000000515BI0100001196
85 8.01 M&L for Attending and Rectifying Minor AC's/Cooling Appliances Complaints (on Daily Basis) within 24 HOURS in DOMESTIC/TECH AREA at AF STATION SIRSA, complete all as specified and directed.\nNOTE : Mechanic will be well qualified and equipped with all T&P required for rectifying the AC's/Cooling Appliances Complaints. BI01010001010000000000000515BI0100001197 500 EACH COMPLAINT
86 8.02 S&F Connection Lead 3 Core, PVC insulated and sheathed Copper Cable size 2.5sqm including taking out/ down unserviceable one, complete all as specified and as directed. MAKE: EMPIRE/ PLAZA BI01010001010000000000000515BI0100001198 20 RM
87 8.03 Supply and fixing MCB 32 Amp, Single Pole, 220 Volt, 50 Hz, suitable for split AC 1.5/2.0 Ton with necessary Connections with Thimbles, etc. including Taking down/out unserviceable MCB, complete all as specified and as directed. Make: Havells/L&T/Legrand/HPL/Schneider BI01010001010000000000000515BI0100001199 20 EACH
88 8.04 S&F 20 Amp metal socket with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed. Make: SCHNIDER/HAVELLS/STANDARD BI01010001010000000000000515BI0100001200 10 EACH
89 8.05 S&F 20 Amp metal plug with earth for AC box including taking out/ down unserviceable one, complete all as specified and as directed. Make: SCHNIDER/HAVELLS/STANDARD BI01010001010000000000000515BI0100001201 10 EACH
90 8.06 S&F 20 Amp AC box with metal plug and socket without MCB including taking out/ down unserviceable one, complete all as specified and as directed. Make: SCHNIDER/HAVELLS/STANDARD BI01010001010000000000000515BI0100001202 10 EACH
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail