Repair / Maintenance Of Summer Appliances With Connected Works At Af Stn Sirsa-Air Conditioner ( Window Type ) , M&L Repairing And Maintenance Of Ac 1 . 5 / 2 . 0 Ton Window Type At Different Location By Taking Out / Down From Existing Position / Location And Re-Installation After Overhauling , Washing And Cleaning Cooling Coil And Condenser Along With Fittings First With Air Blower , Then With Spraying With Coil Cleaning Chemical Of Best Quality In Coil And Condenser , Then Washing With Plain Fresh Water Until All Chemicals Are Removed And Testing , Complete All As Specified And As Directed . , S&F Blower And Condenser Fan Blade With Allen Nuts ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Motor ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: American Universal / Botliboi , S&F Running Capacitor 36+6 Mfd Suitable For Ac 1 . 5 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 45+6 Mfd Suitable For Ac 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 80 / 100 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Selector Switch Suitable For Ac 1 . 5 / 2 . 0 Ton Window Type Of Any Make Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Thermostatic Switch With Knob Plate And Screws Suitable For Ac 1 . 0 / 1 . 5 / 2 . 0 Ton Window Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , M&L Sealed Compressor Unit Suitable For Ac 1 . 5 Ton Window Type Including Brazing Of Copper Pipe , Cleaning Of Refrigerant System Of Ac , Replacement Of Strainer , Rubber Pads For Foundation , Nuts And Bolts , Etc . And Testing Including Taking Out / Down Unserviceable Sealed Compressor And Connected Items , Complete All As Specified And As Directed . Make: Copeland / Kirloskar / Tacemesh Note: ( A ) Dismantling And Reinstallation Of Outdoor Unit Shall Deem To Be Included In Quoted Unit Rate . ( B ) Transporation Charges Shall Deem To Be Included In Quoted Unit Rate . ( C ) Charging Of Refrigerant Shall Be Measured Separately , M&L Sealed Compressor Unit Suitable For Ac 2 . 0 Ton Window Type Including Brazing Of Copper Pipe , Cleaning Of Refrigerant System Of Ac , Replacement Of Strainer , Rubber Pads For Foundation , Nuts And Bolts , Etc . And Testing Including Taking Out / Down Unserviceable Sealed Compressor And Connected Items , Complete All As Specified And As Directed . Make: Copeland / Kirloskar / Tacemesh Note: ( A ) Dismantling And Reinstallation Of Outdoor Unit Shall Deem To Be Included In Quoted Unit Rate . ( B ) Transporation Charges Shall Deem To Be Included In Quoted Unit Rate . ( C ) Charging Of Refrigerant Shall Be Measured Separately , M&L Taking Out Blower Motor From Ac 1 . 5 / 2 . 0 Ton Window Type , 230 Volt , 50 Cycles , Removing Burnt Winding Wire , Rewinding The Blower Motor With Super Enamelled Copper Winding Wire Of Suitable Size And Providing Insulation Along With Insertion Of Superior Type Of Insulating Materials , Binding , Varnishing And Drying Well After Varnishing , Replacement Of Shaft , Gun Metal Bushes And Rubber Bushes For Blower Motor , Testing On Load After Fixing , Complete All As Specified And As Directed . , M&L Cleaning Gas System With Suitable Chemical , Charging Of Refrigerant , Preventing Of Leakage In The System , Providing Refrigerant With Anti-Moist Substance And Strainer , Copper Capillary Including Replacement Of Filter And Air Filter Of Ac 1 . 5 / 2 . 0 Ton Window Type , Testing On Completion , Complete All As Specified And As Directed . , Air Conditioner ( Split Type ) , M&L Repairing And Maintenance Of Ac 1 . 5 / 2 . 0 Ton Split Type At Different Location By , Washing And Cleaning Cooling Coil And Condenser Along With Fittings First With Air Blower , Then With Spraying With Coil Cleaning Chemical Of Best Quality In Coil And Condenser , Then Washing With Plain Fresh Water Until All Chemicals Are Removed And Testing , Complete All As Specified And As Directed . , S&F In Repairs Auto Circuit Plate With Remote 220 Volt , 50Hz Suitable For Ac Of Any Type ( Window / Split ) Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Fan Blade With Allen Nuts ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Spilt Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Blower Motor ( As Approved ) Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: American Universal / Botliboi , S&F Coil For Outdoor / Indoor Unit Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 3 / 8 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 5 / 8 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 4 / 16 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Copper Tubing Of Size 1 / 2 Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Insulation Sleeve Type Of Best Quality For Copper Tubing For Suction / Discharge Pipe Any Size Including Taking Out / Down Unserviceable One , Complete All As Specified . , S&F Plastic Pvc Pipe Of 25Mm Bore , Isi Mark As Drain Pipe Of Acs Split Type , Fixed To Wall With Necessary Clamps , Screws , Etc . Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . , S&F Running Capacitor 50+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 36+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 100 / 120 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Capacitor 80 / 100 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 45+6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 6 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Running Capacitor 2 . 5 Mfd Suitable For Ac 1 . 5 / 2 . 0 Ton Split Type Including Taking Out / Down Unserviceable One , Complete All As Specified And As Directed . Make: Epcos / Havells / Sharda , S&F Starting Relay Assembly With Cover & Clip Suitable For Ac 1 . 5 / 2 . 0 Ton Capacity , Split Type Including Taking Out / Down Unserviceable One , Complete All As S