Providing Services For Attending Breakdowns And Shutdowns At 220Kv Substations And Lines Under Dgm T O And M West For Two Years . , Charges To Attend The B/Down & Emergency Work At A Particular Site By Providing Skilled B/Down Gang , Not Less Than Six Persons ( All T&P , & Vehicle To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Circuit Breaker ( 3 Poles ) Including Removing Of Connected Jumpers/Clamps/Earth Connection Control Wiring Cables/Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Ct/Pt/Cvt ( 1 Pole ) Including Removing Of Connected Jumpers/Clamps/Earth Connection Control Wiring Cables/Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv Isolator Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 220 Kv La ( 1 Pole ) Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66Kv/ 33 Kv Ct / Pt / Cvt Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66Kv/ 33 Kv Cb Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Dismantling Of 66 / 33 Kv Isolator Including Removing Of Connected Jumpers/ Clamps/ Earth Connection Control Wiring Cables/ Glands . Etc . ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Circuit Breaker ( 3 Poles ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Ct/Pt/Cvt ( 1 Pole ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv Isolator Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 220 Kv La ( 1 Pole ) Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66Kv/ 33 Kv Ct / Pt / Cvt Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66Kv/ 33 Kv Cb Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Erection Of The 66 / 33 Kv Isolator Including Proper Alignment Operational Check , Replacement Of Control Cable And Gland Requiring Of Control Cable And Gland Requiring Of Control Wire , Re-Fixing Of Earth Connection Required Jumpering Of The Equipment To Complete The Job: ( All T&P & Man Power To Be Arranged By Contractor At His Cost ) . , Providing Gas Cutter With Operator For Attending Various Jobs At 220Kv S/Stn . / Linesp Incl . To & Fro Charges . , Providing Welding Machine With Welder For Attending Various Jobs At 220Kv S/Stn . / Lines Incl . To & Fro Charges . , Replace Main Top Bus-Bar , 220Kv/66Kv/33Kv Yard . , Hoisting Of Single/Double Tension Insulators String & Hardware Fitting And Fixing In Position Including Tightening Of Bolts & Nuts , Complete After Dismantling And Lowering Of Damaged Conductor/Disc Insulator String By Taking Tension Of Conductor On A Separate Arrangement Including Opening & Providing Of Jumpers . ( 220Kv Tension Tower ) . , Making Of Dead End ( Tension H/W ) Compression Joint . ( Zebra Conductor ) , Replacement Of Damaged Single/Double Suspension Insulator String By Re-Arranging With Good/New Disc Insulators/Polymer String , After Taking The Load Of Conductor On Alternate Arrangement Including Proper Clamping , Armouring Etc . As Per Site Requirement . ( 220Kv Tower ) , Replacement/Providing Dropper String On Angle Tower Including Fixing Of Suspension Clamp . ( 220Kv Tower ) . , Stringing Of Acsr Zebra Conductor Including Fixing Of Conductor Accessories , Such As Arcing Horn , Vibration Dampers Armour Rods , Tightening Of Clamps And Spacers Etc . , As Per Site Condition . , Re-Sagging Of Acsr Zebra Conductor Including Re-Fixing Of Proper Clamps & Hardware , Wherever Required . , Dismantling Of Acsr Zebra Conductor /Earth Wire Including Proper Rolling & Transportation Of Material Back To Store/Site . , Dismantling Of Earth Wire Including Proper Rolling & Transportation Of Material Back To Store/Site . Earth Wire 19/2 . 5 Mm ( Or 7/3 . 66Mm ) . , Jointing Of Acsr Zebra Conductor With Mid Span Joint Through Compression Joint Machine . , Jointing Of Earth Wire Mid Span Joint Through Compression Joint Machine . Earth Wire 19/2 . 5Mm ( Or 7/3 . 66 Mm ) . , Fixing Of Repair Sleeve On Acsr Zebra Conductor By Using Compression Machine . , Stringing Of Earth Wire 19/2 . 5 Mm ( Or 7/3 . 66Mm ) Or Any Other Size Including Fixing Of Accessories & Necessary Hardware & Connection With Running Earth Wire , Earthing Arrangement For Continuity . ( 220Kv Lines ) , Re-Sagging Of Earth Wire Including Tightening Of Suspension Clamps 19/2 . 5 Mm ( Or 7/3 . 66 Mm ) Or Any Other Size . ( 220Kv Lines ) . , Repairing Of Jumper / Replacing Of Conductor And Pg Clamps/ C Fire Wedge Connectors/ Compression Joint Or Providing Parallel Conductor On Acsr Zebra/Bersimis With Pg Clamps Etc . ( 220Kv Lines ) .