Supply And Installation Of 15 Kva Diesel Generator Set At Moyolam Gas Crematorium , Supply And Wiring Points According To Is 732-1989 Using Rigid Pvc Conduit Of Minimum Size 20 Mm With Specials Conforming To Is 9537 Part Iii 1983 And With Suitable Size Specials Conforming To Is 3419-1988 , Fixing The Conduit Using Metal Saddles Spacing Not Exceeding 50 Cm Or Concealed Suitably And With 1 . 00 Sq Mm Frls Pvc Insulated Stranded Single Core Copper Conductor Cable 650V Grade , Including Providing Switch Board Main And Continuous Earthing With No . 14 Swg Bare Copper , Required Quantity Of Copper Earth Socket , Brass Bolt And Nut Crimping / Soldering Etc Complete With Suitable Size Modular Type Metal Switch Boxes , Modular Type Front Plates ( White ) Etc . Up To And Including 6A Modular Type Sp Switches And Making Good The Surface Of Wall , Colour Washing Etc . Complete . All The Terminations In The Switch Boards And Dbs Shall Be Tinned And The Wires Shall Be Drawn And Fixed Along The Periphery Of The Box Using Suitable Ties , Tie Mounts Etc As Required . ( Rohs Compliant Modular Accessories ) . Single Control Light Point With 6A , Plate Ceiling Rose - Short Point , Supply Conveyance , Installation , Testing And Commissioning Of 20W Led Street Light Output Greater Than 105Lumen / W 4000-6000 K With Ip 66 Protection Led Chip Make Cree / Lumilled / Nichea With Power Factor Greater Than 0 . 95 At Full Load , Internal Surge Protection Up To 8 Kv , And Aluminium Pressure Die-Cast Powder Coated Housing , Acrylic Cover Complete With Thd Less Than10% , Power Factor Greater Than 0 . 98 , Rohs Compliant , Duly Wired Up For Use On 230 V Ac Supply . Driver Compartment Should Be Seperatly Accessible For Maintenance ( Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer ) , Supply , Conveyance , Installation , Testing & Commissioning Of 3 Phase , 15 Kva Diesel Generator Set Withntegral Acoustic Enclosure As Per Cpcb Norms With Standard Accessories As Per Technical Details Givenbelow . 1 . Engine : A ) Make Of Engine - Kirloskar / Escorts / Cummins / Mahendra B ) Type Of Engine - Diesel Engine C ) No . Of Cylinders - As Per Manufactures Standards . D ) Method Of Cooling - Air Cooled Withradiator . E ) Aspiration Turbo Charged After Cooled . F ) Design - Suitable For Generating Set Operation G ) Engine Capacity 1880 Cc , 2 . Standard Accessories With Diesel Engine A ) Fly Wheel To Suit Flexible Coupling B ) Close Coupling C ) Air Cleaner D ) Radiator With Fan Provided With Fan Guard . E ) Fuel Pump F ) Mechnical Governor Of Class A1 ) Fuel Filter H ) Lubricating Oil Filter I ) Exhaust Silencer J ) Exhaust Muffler K ) Battery Charger / Generator 3 . Engine Instrument Panel With The Following Items A ) Starting Switch With Key Or Button B ) Lubricating Oil Pressure Gauge . C ) Temperature Gauge . D ) Rpm Indicator With Hour Meter E ) Battery Charging Ammeter 4 . Safety Controls For Engine A ) Trip For Low Lubricating Oil Pressure B ) Trip For High Water Temperature . 6 . Brushless Alternator A ) Make - Kirloskar / Kel / Crompton / Greaves / Stanford B ) Type - Self Exited And Self Regulated . C ) Capacity - 15 Kva / 12 K W @ 0 . 8Pf D ) System Of Voltage - 3 Phase , 415 V , E ) Frequency - 50 Hz F ) Insulation - Class F / H , Brushless Alternator With Automatic Voltage Regulation Vg3 . The Alternator Should Confirm To Is:13364 ( Part-1 ) . Operation And Service Manual , Spares And Tools Shall Be Provided . 7 . Fuel Tank Suitable Size Built In Type Integrated With The Acoustic Enclosure Fuel Connection Shall Be Done As Per Standards 8 . Battery Suitable Size Built In Type Integrated Battery With Leads And Terminals Of Appropriate Ah Capacity As Per Manufactures Requirement . Automatic Battery Charger Solid State Phase Indication Lamp For Supply On / Off With Hrc Protection . Standard Conrol Panel Wih 25 A 4P Mcb And Accessaries Such As Multi Function Meter And Separate Energy Meter Etc . Complete , Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms , Lift Upto 1 . 5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed , Within A Lead Of 50 Metres . , Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump , Dg Set Etc Including Form Work Etc As Required , Providing Brick Work ( In Width 225 Mm Or More ) With F . P . S . Bricks Of Class Designation 7 . 5 In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) At All Levels . , Providing 15Mm Thick Cement Plaster Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) At All Levels . , Supply And Providing The Following Size Of B Class Ms Pipe Conforming To Relevant Is Specificationscomplete With Heavy Guage Specials Such As Bends , Flanges Etc Welded And Fixed At Appropriatelocations , Providing Cork Sheet In Between The Flanges At The Joints , Bolting The Flanges Together , Paintingthe Pipe , Flange Etc With 2 Coats Of Heat Resistant Paint Suitable For Outdoor Applications , Fixing The Pipefirmly With Fabricated Structure / Wall / Any Other Mechanical Support Etc As Required . - 80 Mm Dia B Class Ms Pipe As Extended Exhaust Pipe . , Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1 . 1Kv Grade Of The Following Sizes In The Existing Rcc / Hume / Stone Ware / Gi / Dwc Pipe As Required . 4 Core 10 Sq Mm , Supply & Laying Of Dwc Pipe In Ordinary Soil 0 . 75M Below Ground Level Including Excavation50 / 38 Mm Or Nearest Size , Supply , Laying And Clamping Of 1 No . Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable , 1 . 1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables , Spacing Of Clamps Not Exceeding 60Cms , Making Good The Damages , Colour Washing Etc . As Required . 4 Core 10 Sq Mm With Factory Made Clamp , Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1 . 1 Kv Grade As Required . 4 X 10 Sq . Mm ( 25Mm ) , Earthing With G . I . Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories , Andproviding Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2 . 7 Metre Long Etc . With Charcoal / Coke And Salt As Required . , Providing And Fixing 2 X 25 Mm X 3 Mm G . I . Strip Test Joint For Earthing System , Providing And Fixing 25 Mm X 3 Mm G . I . Strip Earth Lead From The Test Joint To The Earth Plate , Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring / Cables And Giving Connection As Required3 . 15 Mm Copper Conductor ( 10 Swg ) , Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc . As Required . 3 . 15 Mm ( 10 Swg ) , Supply And Laying Of The Following Sizes Of B Class Gi Pipe Laid 0 . 6 M Below Ground Level Including Excavating Trench Of Suitable Size And Refilling Etc , As Required . 15 . Mm Dia . G . I Pipe ( Medium Class ) , Supply And Installation Of Switch Gear Units In Sheet Steel Enclosure Complete With Handle Assembly , Door Interlock And Pad Locking Arrangement Of The Following Ratings On Existing Angle Iron Frame Work Or Directly To Wall Using Necessary Bolts & Nuts , Fixing The Unit To Wall , Making Good The Damages , Color Washing Etc . Including Giving Necessary Connections As Required . ( Excluding Cost Of Hrc Fuse Links In Case Of Sdf / Sdfco ) 32 A , 4 Pole On Load Changer Switch In Sheet Steel Enclosure , Fee To Be Paid To Kselb Towards Scrutiny & Inspection , Meter Testing Etc ( Actual Amount Will Be Reimbursed On Production Of Original Documents ) , Copying Charges Of Electrical / Fire Drawing Per A3 Sheet Additional Copies , Charges For Preparation O