}

Removal Of Request-E And Installation Of Cms And Sdn Onboard Ins Mumbai, NAVAL DOCKYARD MUMBAI-Maharashtra

Indian Navy has published Removal Of Request-E And Installation Of Cms And Sdn Onboard Ins Mumbai. Submission Date for this Tender is 16-06-2020. Electromechanical Services Tenders in NAVAL DOCKYARD MUMBAI Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

23891695
Corrigendum : Removal Of Request-E And Installation Of Cms And Sdn Onboard Ins Mumbai
Tender
Indian
Maharashtra
Naval Dockyard Mumbai
16-06-2020

Tender Details

Removal Of Request-E And Installation Of Cms And Sdn Onboard Ins Mumbai:-1 Request- E ( Ops Room ) -Degutting And Removal Of Existing Dev 171-A Qty-03 ( Dimension 1230*12130*1575Mm ) Request- E Equipment Room- Degutting And Removal Of Existing Converter Att-20-400 ( Dimension 700*1220*590Mm ) ( Includes Removal From Onboard Location To Jetty Or Upper Deck Of Ship As Specified By Ship ) 2 Services – Request- E Control Post- Degutting And Removal Of Existing Dev-198 ( Dimension 665*433*868Mm ) Dev-119 ( B ) Qty-03 ( Dimension 665*434*868Mm ) , Dev-119Ж ( Dimension 665*434*1103Mm ) , Request- E ( Ops Room ) -Degutting And Removal Of Existing Dev-26A-1 ( Dimension 1270*331*588Mm ) , Dev-26-1 ( Dimension 994*331*585Mm ) , Dev T-75 ( Dimension 665*433*868Mm ) ( Includes Removal From Onboard Location To Jetty Or Upper Deck Of Ship As Specified By Ship ) 3 Services – Request- E ( Ops Room ) - Degutting And Removal Of Existing Dev-125 Qty-03 ( Dimension 738*260*360Mm ) Dev26 ( B ) -1 ( Dimension 695*287*585Mm ) , Dev 193-1 ( Dimension 626*393*360Mm ) , Dev T-9 ( Dimension 402*235*429Mm ) Request- E Control Post- Degutting And Removal Of Existing Dev-175-2 ( Dimension 520*235*796Mm ) , Db T- ( P ) ( Dimension 235*354*92Mm, Weight- ) , Db T- ( Y ) ( Dimension 520*235*796Mm ) , Db T- ( Y ) -5 ( Dimension 564*235*986Mm. ) Riu Unit ( Dimension 500*300Mm ) Request- E Equipment Room-Degutting And Removal Of Existing Voltage Contro Unit Ph-43P ( Dimension 307*257*130Mm ) Switching Unit Y ( B ) P-13P ( Dimension 428*488*224Mm ) , Rectifier ( Dimension 550*366*292Mm ) , Filter ( Dimension 449*390*276Mm ) Magnetic Starter ( Dimension 300*182*394Mm ) , Transformer ( Dimension 175*190*182Mm ) , Resistance Box ( Dimension 530*390*200Mm ) , Starter ( P ) T-3232 ( Dimension 485*535*204Mm ) , T ( Y ) -10 ( Dimension 573*235*720Mm ) , T- ( Y ) -8 Qty-02 ( Dimension 589*235*986Mm. ) ( Includes Removal From Onboard Location To Jetty Or Upper Deck Of Ship As Specified By Ship ) 4 Services – Request- E ( Ops Room ) - Degutting And Removal Of Existing Dev T-98 Qty-03 ( Dimension 800*1070*1700Mm ) , Request- E Control Post- Degutting And Removal Of Existing Dev T-162A ( Dimension 665*433*868Mm ) , Dev T-155 ( Dimension 665*529*1103Mm ) , Dev-181A ( Dimension 665*439*1103Mm ) ( Includes Removal From Onboard Location To Jetty Or Upper Deck Of Ship As Specified By Ship ) 5 Degutting Of Existing Cable 6 Removal Of In Way Electrical Equipment Like Starter, Junction Boxescontrol Panel And Light Fittings Etc. 7 Removal Of In Way Equipment Like Ducting, Air Pipe Tool Rack, Fire Box, Pre-Wetting System Etc. 8 Service - Fitments Of 20 Standard Nodes And 08 Dmfcs Of Cms And Sdn At Various Locations Onboard. 9 Service -Shifting Of 20 Cms 16A Sub Units ( Weight 15-25 Kgs Each ) From Shop Floor To Ship. 10 Service -7 In Nos Dmfcs To Be Installed In Ops Room 11 Service - Installation Of Following In Ops Room -Pds / Chart Server, Network Health Monitoring System, Switching Unit For Remote Display ( Surd ) , Vertical Remote Display. 12 Service - 03 In Nos. Concentrators, 02-Interphones / Intercoms, 05 Jbs To Be Relocated In The Ops Room 13 Service - All Icm Module ( Qty-08 ) Stands Are Required To Be Installed In A Separate Stand Besides Dmfc. 14 Service - A Communication Rack Required To Be Fabricated To House One Oc Of Link Ii And One Itu Besides Dmfc. Material To Be Catered By Vendor. 15 Service -A 72 Display Need To Be Installed In Ops Room. A Customized Bracket With Foldable Hinges And Securing Arrangement To Be Fabricated. 16 Service -One Dmfc To Be Installed In Bridge. ( Refer To Bps For Dimensions And Weight ) 17 Service -A Customized Rack For Link Ii Needs To Be Fabricated And Installed Next To Dmfc In Bridge. Material To Be Catered By Vendor. 18 Service - Laying Of Cable In Channel Tray For Cms 19 Service -Trunking To Be Fabricated ( 200Mm*300Mm & 5 Mtrs Length ) And Bulkhead Piercing Is Required For The Same. Material For Trunking To Be Catered By Vendor 20 Service -Laying Of New Pipe For Connection Of Fireman System ( Approx 30Mtrs ) With Marine Ac. Pipe And End Connections To Be Catered By Vendor. 21 Service -One Dmfc To Be Installed In Flag Bridge. 22 Service -A Customized Rack For Link Ii Needs To Be Fabricated And Installed Next To Dmfc In Flag Bridge Bridge. Material Required For Fabrication To Be Catered By Vendor 23 Service -Trunking To Be Fabricated ( 200Mm*300Mm & 5 Mtrs Length ) And Bulkhead Piercing Is Required For The Same. Material Required For Trunking To Be Catered By Vendor. 24 Service -Installation Of Two In Nos. Computer Complex, Two In Nos. Esis, One In Nos. Rddu And Switching Unit For Cctv Camera. 25 Service -Installation Of Power On Control Module ( Pocm ) , Remote Power On Module ( Rpom ) , Colour Printer And Plotter. 26 Service -Installation Of Ups Battery And Isolation Transformer. 27 Service -Laying Of Cable In Channel Trays For Sdn 28 Service -02 Ees , 03 Lius, Gateway Switch-B, Battery Rack, Ups-3Kva Installation. 29 Service -Relocation Of Power Panel Jb, Fabrication Of Supporting Platform In Order To Locate Lius Ees And Gateway Switches. 30 Service -Installation Of Mpio, Ctp, Ups-3Kva, Battery Rack, Liu Type-B. 31 Service -Relocation Of Two Junction Boxes With Associated Cabling And Fabrication Of Supporting Platform For Fitment On Bulkhead. 32 Service -Installation Of Core Switch-B, Distribution Switch-B, Server Rack, 3- Battery Rack, 10-Liu Type-B. 33 Service -Installation Of Core Switch, Distribution Switch, Server Rack, Mpio, Ctp, 9-Liu Type-B & 3- Ees. 34 Service -Installation Of 4-Ups-3Kva 4-Battery Rack. 35 Service -Installation Of Mpio –I, Ctp, Ups-3Kva, 2-Battery Rack, 2-Liu Type-B, Gateway Switch, Ehfs #1, Ups-1Kva, Step Down Transformer For 1Kva Ups, Pdp. 36 Service -Installation Of 04-Gateway Switch, 06-Ups-1Kva , 06-Step Down Transformer, 06-Battery Rack, 10- Liu Type-B. 37 Service -Installation Of 2- Ees, 1-Liu Type-B, Ups-1Kva , Step Down Transformer & Ups-3Kva ( Refer To Bps For Dimensions And Weight ) 38 Services -Installation Of Gateway Switch, Ees, 3-Liu Type-B, 2-Ups-1Kva , 2-Step Down Transformer ( Refer To Bps For Dimensions And Weight ) 39 Service -He Starter Panel In Rx Room To Be Relocated As Per The Specified Position To Accommodate Step Down Transformer. 40 Service -Installation Of Ees, Liu Type-B, Ups-1Kva , Step Down Transformer , Battery Rack. 41 Service -Relocation Of 15 Kva Transformer, Main Broadcast Speaker, Signal Intercom Including Fabrication Of Mounting, Shock Mounts 42 Service -Sdn Units To Be Shited In As Per The Shipping Route. 43 Service -Laying Of Cable In Channel Trays 44 Service -Laying And Manufacture Of 300 Mtrs Channel Tray 45 Service -Laying Provisioning And Fitment Of Cable Conduit 60 Sq Mm 46 Service -Fitment Of New Mct Gland Coming With Penetrations Of Bulk Heads 47 Service -Manufacture And Fitment Of Cable Tallies 6X3x0.5 Mm - Aluminum ( Punched ) 48 Service -Termination Of Old / Unused Cables By Terminating The Shield Circumferentially And Grounding The Core At Both Ends. Proper Bonding And Grounding Of All Units Ar Per Necstd 1101 49 Service -Manufacture And Fitment Of Clamps For Mounting Of The Channel Trays And Bulkhead Mounted Devices, As Required 50 Service -Resiting / Blanking Of The Existing Ventilation Trunking Feeding The Cabinets At All Locations Along With Removal And Refitment Of The Ac Trucking For Shipping In And Installation Of Cabinets. 51 Service -Resiting Of The Existing Light Fixtures And Manufacturing Of Additional Cable Trays In All Compartments During Installation And Associated Regutting And Hot Work 52 Service -Provisioning Of All Tools, Equipment Slings , Vehicles Or Any Other Item Required For Undertaking The Above Mentioned Work 53 Removal Of Microtech Tiling 54 Removal Of Lagging For Fabrication Job

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 06-05-2020 EXTENSION OF BID SUBMISSION Date 01-06-2020
2 13-04-2020 EXTENSION OF BID SUBMISSION AND TENDER OPENING DATE Date 07-05-2020
3 23-03-2020 CORRIGENDUM Date 14-04-2020
4 28-05-2020 DATE CORRIGENDUM Date 16-06-2020

Key Value

Document Fees
Refer document
EMD
INR 113000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail