Tender For Generation Of Solar Energy Of Capacity Of 1.5 Mw At Af Stn Agra, GE AF ADM AREA KHERIA AGRA-Uttar Pradesh

Military Engineer Services-MES has published Tender For Generation Of Solar Energy Of Capacity Of 1.5 Mw At Af Stn Agra. Submission Date for this Tender is 05-06-2020. Solar Product Tenders in GE AF ADM AREA KHERIA AGRA Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

23883852
Corrigendum : Tender For Generation Of Solar Energy Of Capacity Of 1.5 Mw At Af Stn Agra
Open Tender
Indian
Uttar Pradesh
GE AF ADM AREA KHERIA AGRA
05-06-2020

Tender Details

Tender For Generation Of Solar Energy Of Capacity Of 1.5 Mw At Af Stn Agra

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 24-Mar-2020 DATE AMENDMENT..... Date 11-04-2020
2 31-Mar-2020 DATE AMENDMENT Date 27-04-2020
3 18-Apr-2020 DATE AMENDMENT........ Date 16-05-2020
4 04-May-2020 REVISED BOQ BOQ 16-05-2020
5 09-May-2020 AMENDMENTS IN CRITICAL DATES Date 23-05-2020
6 13-May-2020 TWO REVISED DRAWINGS Other 23-05-2020
7 15-May-2020 Amendment in EMD Fee 23-05-2020
8 15-May-2020 Re revised BOQ BOQ 26-05-2020
9 18-May-2020 CHANGE IN CRT DATES ...0 Date 29-05-2020
10 29-May-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 05-06-2020
11 01-Jun-2020 AMENDMENT NO 5 Other 05-06-2020

Key Value

Document Fees
INR 3000 /-
EMD
INR 849970.0 /-
Tender Value
INR 10.49 Crore /-

BOQ Items

Name of Work: GENERATION OF SOLAR ENERGY OF CAPACITY OF 1.5 MW AT AF STN AGRA
1 2 3 4 5
1 1 SCHEDULE A PART I (BUILDING WORKS)
2 1.01 Construction of a building containing power room,duty room and store room complete all as specified and as shown in drawing No.CE/ALD/SD/38 AR and all connected drawings including ramp etc complete. 1 Each Block
3 2 Sch A Part II (INTERNAL WATER SUPPLY)
4 2.01 Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II. 1 Lump Sum
5 3 Sch A Part III (EXTERNAL WATER SUPPLY)
6 3.01 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY, as listed in Sch ‘A’ Part- III . 1 Lump Sum
7 4 Sch A Part IV( EXTERNAL ELECTRIFICATION)
8 4.01 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Sch ‘A’ Part-IV. 1 Lump Sum
9 5 Sch A Part V (ROAD/PATH & CULVERT)
10 5.01 Lump sum price worked out by the contractor for ROAD/PATH & CULVERT ,as listed in Sch ‘A’ Part- V. 1 Lump Sum
11 6 Sch A Part VI (AREA DRAINAGE)
12 6.01 Lump sum price worked out by the contractor for AREA DRAINAGE ,as listed in Sch ‘A’ Part- VI. 1 Lump Sum
13 7 Sch A Part VII (COMPOUND WALL/ GATE)
14 7.01 Lump sum price worked out by the contractor for COMPOUND WALL/ GATE ,as listed in Sch ‘A’ Part- VII. 1 Lump Sum
15 8 Sch A Part VIII (SEWAGE DISPOSAL)
16 8.01 Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ Part- VIII. \n \n 1 Lump Sum
17 9 Sch A Part IX ( SITE CLEARANCE, EXCAVATION AND EARTH WORK)
18 9.01 Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION AND EARTH WORK as listed in Sch ‘A’ Part- IX . 1 Lump Sum
19 10 Sch A Part X (SOLAR POWER GENERATOR & MISCELLANEOUS ITEMS)
20 10.01 Design, supply, install, testing and commissioning of ground based solar power generating system without battery of capacity 1.5 MW AC output , peak grid tied solar photo voltaic system complete with the components specified below. Design shall be done from MNRE approved channel partners of Rating as specified in NIT and according to latest IS/IEC code and MNRE latest guidelines and specifications tentatively as shown in Drgs. Final design & Drgs of the subject work has to be vetted by any one of the following approved agencies: -\n(i) National Institute of Solar Energy \n(ii) Sardar Swarn Singh National Institute of Renewable Energy \n(iii) Solar Energy Corporation of India (iv) The Indian Renewable Energy Development Agency :- 1 Each Job
21 10.02 Solar PV modules of minimum rating 320 Wp with minimum 72 cells, Poly Crystalline Module shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 complete all as specified. Qty of solar PV module shall be tentatively 5625 Nos for 1.5 MW AC output. \nNote :- \n(i) Each PV module used in this work shall have RF identification tag. \n(ii) Solar PV Modules: Modules shall be warranted for a minimum period of 25 years. PV modules shall be warranted for their output peak watt capacity, which shall not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall be warranted for any manufacturing defect or bad workmanship for a period of 25 years from the date of completion of Phase-I of the work. The contractor shall submit necessary warranty certificate for 25 years to GE. The condition 46 of IAFW 2249 shall be amended to the extent as mentioned above. \n(iii) Modules should be in conformity of latest technical specification issued by MNRE from time to time and makes as approved by MNRE.\n(iv) An amount equal to Rs. 5,00,000(Rupees Five Lakh Only) shall be retained from the contractor’s bill against the warranty as performance guarantee for a period of 5 years from date of completion of job . Alternatively the contractor may give a separate interest bearing security deposit/BGB in favour of GE valid for 05 years. This amount shall be refunded to him by GE after a period of 05 years. under the conditions provided for by the contract and arising solely from faulty materials or workmanship, provided such defective parts are not repairable at site.\n(v) During the period of warranty the contractor shall remain liable to replace any defective parts that become defective in the plant.
22 10.03 Hot dip galvanised MS angle module mounting structure for solar panels of combined capacity1.5 MW,AC output with double pole static structure of suitable size along with concrete grouting for required rigid support as required at site as per OEM/ MNRE Norms recommendations capable to with stand maximum wind load as designed for angle of modules all as required as per site.
23 10.04 Supply, install, testing and commissioning of Central Inverter/PCU, DC to AC (indoor type) of capacity 3x500 kW AC or next higher side capacity suitable for 1.5 MW AC inputs with minimum 4(+/-) load each with SCADA capabilities as specified housed in OEM provided complete. \nNote :-\n(i) Power Conditioning Units (PCU): PCUs shall be warranted for minimum period provided by the manufacturer but not less than 5 years. PCUs shall be warranted for any manufacturing defect or bad workmanship for a minimum period of 05 years from the date of completion of Phase-I of the work. The contractor shall submit necessary warranty certificate for 05 years to GE. The condition 46 of IAFW 2249 shall be amended to the extent as mentioned above. \n(ii). During the period of Warranty the CONTRACTOR shall remain liable to replace any defective parts that become defective in the plant, under the conditions provided for by the contract and arising solely from faulty materials or workmanship, provided such defective parts are not repairable at site. After replacement the defective parts shall be returned to the CONTRACTOR. \n
24 10.05 Supply, install, testing and commissioning of String monitoring/combiner box of type 22 in 1 Out with 10 Amp fuse on positive side, 200 Amp manual DC disconnector switch & 22 Channel monitoring as required at site complete. \n
25 10.06 Supply, install, testing and commissioning of Copper DC String cables of different sizes of suitable size as required at site of Solar grade, including suitable lugs/ male, female connectors etc , UV resistant 1.5 kV DC Cables confirming to IEC IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24., IEC 61034, temperature range -40° to +90° C, complete.
26 10.07 Supply, install, testing and commissioning of Data monitoring system communication cable RS 485 [screen twisted] as required at site complete. \n
27 10.08 Supply, install, testing and commissioning of Inverter communication Shielded CAT5 cables as required at site complete. \n
28 10.09 Supply, install, testing and commissioning of Solar Observatory system or Weather Station complete all as specified and directed consisting of following:-\n(i). Pyranometers: 1\n(ii) Rain Guage: 1\n(iii). Module Temp Sensor: 4\n(iv) Ultrasonic Anemometer: 1\n(v) Temp & relative Humidity Meter: 1\n(vi) Solar Panel (35 W) + Battery Bank: 1\n(vii) Data Logger: 1\n\nNote : All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts of data simultaneously round the clock. All data shall be stored in a common work sheet chronologically. Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen
29 10.1 Supply, install, testing and commissioning of Lightening protection system of Early Streamer Emission type Lightening Spike with 107 m protection at level 3 for Protection ( duy supported by tech literature) against lightning strikes with GI mast of 8.5 Mtrs long with Remote Performance Monitoring System complete all as specified and directed by the Engineer-in-charge and shall have following :- \n (i) Inverter Data Monitoring \n (ii) Energy Meter Data Monitoring \n (iii) Weather Station Monitoring.\n\nQty of lightening arrester shall not be less than 4 Nos including suitable size of copper strip upto earthing test point.
30 10.11 Supply and installation of Earthing shall be provided for string monitoring/combiner box, Inverter, Solar PV module, Array structure, Panels complete entire system complete with suitable size of Copper Cable including Termination acceesaries as required at site & confirming to latest IS/ IEC all as specified and directed.
31 10.12 Supply, install, testing and commissioning of Main distribution board Floor Mounted DC Panel, DC Bus, Auxiliary Buses for required load as per site requirement on DC side of inverter complete. \n
32 10.13 Supply, install, testing and commissioning of Main distribution board Floor Mounted AC Panel, AC Bus, Auxiliary Buses for required load as per site requirement on AC side of inverter complete all as specified and directed . \n
33 10.14 Supply, install, testing and commissioning of UPS with battery bank of 5 kVA with 60 minutes backup at 100 % load as per design & specifications for Solar System critical components, Industrial type Onine UPS with static switches for bypass complete.
34 10.15 Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp complete all as required at site.\n\n\n
35 10.16 Supply, install, testing and commissioning of Main DC Cables of off sizes as required at site, Aluminium, armoured Cable confirming to EN 50618 complete.
36 10.17 Supplying, laying, testing and installation of LT Power Cable inverter to transformer of AC Cables of off sizes as required at site, 1.1kV Al Armoured LT cable as per IS 7098 complete all as specified and directed.
37 10.18 Supplying, laying, testing and installation of LT Aux (DC & AC) control cables for UPS input, transformer, Inverter, panels of suitable size, 1.1kV copper LT cable as per relevant IS complete all as specified and directed.
38 10.19 Supply & fixing earth continuity conductor or main earthing lead copper cable or GI strip of suitable size as required at site.
39 10.2 Supply, install, testing and commissioning of Lightning Arrester ESE type with 107 m protection at level 3 for Protection against lightning strokes with Remote Performance Monitoring System complete all as specified and directed by the Engineer-in-charge and shall have following :- \n (i) Inverter Data Monitoring \n (ii) Energy Meter Data Monitoring \n (iii) Weather Station Monitoring.
40 10.21 Supply, install, testing and commissioning of Industrial type computer (one No.) rugged & robust in nature to operate in a hostile environment. The computer shall be of HP make or of equivalent make having i5 or better processor with minimum 1 TB of hard drive, 21" LCD colour monitor, DVD Drive with writer, multimedia kit and UPS with 30 min Power back up as per HP model 23 q141in or technocommercially equivalent model.
41 10.22 Supplying and laying of Suitable size HDPE pipe 6kgf/cm2 rating for cable protection including all necessary fittings and fixing arrangement complete as required at site all as specified and directed. Note:- Necessary earth work, sand cushioning, protection pipe, bricks etc shall deemed to be included for laying of cables, HDPE pipe up to power transformer.
42 10.23 Supply black and white laser printer (one No) as per HP model number M1005 or technocommercially equivalent model in other make as approved by GE. The printer shall be equipped for printing, scanning, copying and fax complete.
43 10.24 M & L for Earthing with 600 X 600 X 6.00 mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Galvanised steel Strip of size 32 X 6 mm by means of bolts, nuts and check nuts and washers of galvanised steel with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note:- Nos of earthings shall be provided as required at site as per IE/IEC rule. \n \n
44 10.25 M & L for Earthing with copper earth plate 600x600x3mm, earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including copper earth strip 25x3 mm by means of bolts, nuts and check nuts and washers of copper with and including 40 mm dia GI medium grade pipe for protection of copper strip to the extent of 7.5 metres as earthing lead all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete. \nNote :- Nos of earthings shall be provided as required at site as per IE/IEC rule. \n \n
45 10.26 Supply, install, testing and commissioning of Surge Protection device complete all as specified and directed.
46 10.27 Supply, installation, testing and comissioning of Inverter duty step up transformer of 1250 KVA (copper wound outdoor type) or nearest size on heigher side, 0.30/11 KV per IS -1180 or as per latest IS as amended complete all as specified and directed. \n Note :- \n(i). First fill of oil as per manufacturer instructions shall deemed to be included in the unit rate quoted by contractor. \n(ii). Plinth for transformer including 40mm to 100 mm graded stone metal aggregate 1.5m wide and upto 3m deep around transformer plinth with and including slant slot for accomodating 100 mm dia pipe on both LT & HT side with clamping arrangement of size and specifications as per manufacturer instructions, shown on drawings and as directed by the Engineer-in-charge complete shall deemed to be included in the unit rate quoted by contractor .
47 10.28 Supply and laying sub class 'B' bricks in cable trenches as cable protection complete all as specified and directed (For LT Cable only) 21360 Each
48 10.29 Supply, installing, testing and commissioning of HT 11 KV , 3 Phase,50 Hz, indoor type, totally enclosed metal clad switchgear complete with stand alone Vacuum Circuit Breaker (VCB) having rupturing capacity 250 MVA, Over load and Earth Fault protection, Ammeter, Volt Meter and rating up to 400 Amps and both side extendable including necessary battery bank with charging arrangement complete all as specified and as directed by Engineer-in-Charge and of following specifications :- 2 Each
49 10.3 (a) Motorised spring charging mechanism with 24 volt DC universal motor 200 watts and having charging time less than 5 seconds.\n(b) Earthing Switch rated for full making capacity with provision for safe & reliable position indicator
50 10.31 c) i) Assembly of Vacuum Circuit Breaker shall be completely insulated as per the relevant IS.
51 10.32 ii) The rating of VCB shall be 11 KV,400 Amps, 21 KA (for 3 Sec) , 50 Hz, 3 phase
52 10.33 iii) The vacuum interrupture bottle shall have to be manufactured by the OEM
53 10.34 iv) Electrically charged and electrically operated independent closing / tripping, trip free, operating mechanism including manual closing / tripping push button and breaker close / open option shall have to provided.
54 10.35 v) One bus Bar Chamber including a set of 3 phase 600 Amps copper bus Bars to be provided for further extension in future, if necessary.
55 10.36 vi) Strip Heaters to be provided with the following specifications :-\nPower input 80 watts with Voltage rating 230 volts AC Single phase
56 10.37 vii) Current Transformer (CT) chamber comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 1, burden not less than 2,5 VA and accuracy class 1.0, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 02 Sets.
57 10.38 viii) 1 No. Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, Burden 50 VA, Accuracy class 1.0 with HT & LT HRC fuses for primary and secondary complete all as specified and as directed as per IS: 3156 - 01 Set
58 10.39 ix) SCADA compitable self powered numerical over current & earth fault relay for complete protection of HT ,11 KV,3 Phase feeder having facility to record fault current with MODBUS communicationon RS 485 communication port - 01 No including 1 No voltage monitoring relay for under voltage / over voltage protection.\nMake : AREVA / ABB / SCHNEIDER / SIEMENS / ASHIDA / CSDPR
59 10.4 x) Digital SCADA compitable meter of accuracy class 1, as per IEC 62052-11 / IEC 62053-22 monitoring all electrical parameters like votage, current, demand, Watt, VA, VAR per phase. Also to monitor all instanteneous integrated demand,parameters, neutral current, frequency,power factor, % load, % unbalance (V&I), phase angle, THD working on MODBUS protocol.\nMake : L&T / SCHNEIDER / RISHABH / ELMEASURE
60 10.41 xi) One set of mechanical indicatior for ON / OFF indication for all LBS / VCB breaker.
61 10.42 xii) One set of capacitive voltage indication for R-Y-B
62 10.43 xiii) One set of battery and battery charger to provide suitable back up as per OEM's instruction
63 10.44 Make : ABB / SCHNEIDER / AREAVA / SIEMENS
64 10.45 Supplying,installation,testing and commissioning 11 KV current transformer of cast resin type 11 KV current transformer having ratio of 100+50/5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 21.1 KV for 1.0 second\nMake : KAPPA / AE / TECHNO ASSOCIATES VIDYUT (P) Ltd, Thane / L.R. Enterprises / ARIHANT Electricals 2 Set of 3 Pcs
65 10.46 Supplying,installation,testing and commissioning 11 KV single phase indoor resin cast PT of ratio (11KV / v3) / (110V / v3) class 0.5 burden not less than 50 VA having insulation class-E , insulation level 12KV/28KV/75 KV,conforming to IS- 3156 including fixing in HT metering Box complete all as specified and directed.( for energy meter )\n Make : KAPPA / AE / TECHNO ASSOCIATES VIDYUT (P) Ltd, Thane / L.R. Enterprises / ARIHANT Electricals 2 Each
66 10.47 Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1500mm width x 750mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming side of MCCBs. For termination of outgoing cables with MCBs, 4 way ebonite cable connector (rating 32 amps) to be provided .TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- \nLocation : Main LT Feeder Pillar 1 Each
67 10.48 PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 100 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting of rating 63 Amps - 01 No. \nMake : LEGRAND /SCHNEIDER / ABB OUTGOINGS :- TPN MCB 32 Amps having breaking capacity 10 KA - 06 Nos \nMake : LEGRAND /SCHNEIDER / ABB
68 10.49 INSTRUMENTATION SYSTEM :- LED Phase Indicating light, shrouded type, 22mm, with cluster LED - 01 set of 3 lamps (RED,YELLOW & BLUE)\nMake : L&T /SIEMENS/ C&S (RASS) Digital Volt Meter (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 No.\nMake : L&T / AE/ CONZERV / ELMEASURE Digital Ammeter (96mm x 96mm), 4 1/2 digit,Accuracy Class 1% - 01 N0\nMake : L&T / AE/ CONZERV / ELMEASURE C.T having Ratio 60/5, tape wound,BPL, rated burden 5 VA - 03 Nos.\nMake : L&T / AE / ELMEASURE / RISHABH\nVolt meter selector switch (6 Amps), 3 position with "OFF" - 01 No.\nMake : KAYCEE / L&T / C&S (RAAS)\nAmmeter selector switch (6 Amps), 3 position with "OFF" - 01 No.\nMake : KAYCEE / L&T / C&S (RAAS)\nSP MCB 6 Amps 10 KA (For Control Wiring) - 03 Nos. \nMake : LEGRAND /SCHNEIDER / ABB\n Danger Notice Plate duly written in Signal Red colour on Aluminium plate in English & Hindi language and of size not less than 150mm x 100mm - 02 Nos\n
69 10.5 Supply and fixing thermoplastic polystyrene / polycarbonate enclosure of overall size 210mm x 155mm x 92mm suitable for street light junction box, shock proof , vermin proof and dust proof complete with terminals for up to 3 phase cable of size 16 Sq mm 4 core and 01 No MCB SP 6 amps including non metalic clapms and GI nut bolts and washers of suitable size and fixed on pole / wall complete and making cable connection as existing all as specified and directed.\nMake of Box : HENSEL(Cat No : DK1616G) OR Equivallent model in RITTAL / GEWIS\nMake of MCB : Legrand / Schneider / ABB /L&T 41 Each
70 10.51 Supply and fixing LED street light fitting 60 - 65 watt complete with Pressure die cast aluminum housing enclosed with glass cover in frame complete and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting bracket made out of 40mm bore light grade GI pipe with suitable size clamp made of 25mm x 5 mm MS Flats, MS nuts,bolts, washers and over voltage protection up to 300 volts complete of 60 watt , inbuilt 5 KV surge protection with 20 KV SPD complete all as directed.\nMake : \nCROMPTON (Cat Part No. LSTO-60-CDL) / \nHAVELLS (Cat Part No. ENDURAPEARLPLUSSL60WLED757SASYTOPC) /\nPHILIPS (Cat Part No. BRP062 LED 65 CW SLA S1 PSU)\n 41 Each
71 10.52 Design, supply, erection, testing and commissioning of outdoor type Street Light Controller Panel of overall size not less than 500mm width x 600mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted through grouting bolt on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply. The panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with2 layer shutter in the front side and single layer shutter in the rear side with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. \nFollowing internal components shall have to be provided duly mounted on a mounting plate :-\n\nLocation : Security Light Controller Panel\n 1 Each
72 10.53 INCOMING\n(i) TPN MCB 16 Amps having breaking capacity 10 KA - 01 No \n Make : LEGRAND /SCHNEIDER / ABB \n(ii) 4 way 30 Amps DMC / FRP Cable Connectors having bolts,nuts,washers etc. - 01 Nos\n(ii) 3 Pole power contactor, suitable for 415 volts AC 50 Hz supply and current carrying capacity 18 Amps (Aux Contact - 1 NO + 1 NC). - 01 No.\nMake : L&T (MNX 18) / BCH / TC\n(iv) DIN rail mounted, Astronomical Time Switch, 1 Channel, suitable for operate in 230 volts AC 50 Hz supply and operating mechanism based on sun rise / sun set timing of a preset lattitude and longitude of a particular location - 01 No.\nMake : LEGRAND (Cat No. - 412654 Alpharex D21 astro) \nOR Equivallent model in SCHNEIDER / L&T \n(iv) 6 Amps rated Rotary type selector Switch for Auto / Manual Selection - o1 No. \nMake : KAYCEE / L&T / C&S (RAAS)\nOUTGOINGS\n(i) TPN MCB 10 Amps having breaking capacity 10 KA - 02 Nos \n Make : LEGRAND /SCHNEIDER / ABB \n(ii) 4 way 30 Amps DMC / FRP Cable Connectors having bolts,nuts,washers etc. - 02 Nos\n
73 10.54 Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and including HDPE pipe of up to 150 mm dia suitable for 0.4 mpa working pressure 40 RM
74 10.55 Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 Amps for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. \n 2 Each
75 10.56 Supply and fixing LED flood light fitting suitable fixing on watch Tower including all fixing arrangement high grade aluminium pressure die cast and toughened glass, minimum lumen efficacy 100 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 110-120 watt , inbuilt surge protection of 5 KV \nMake \nHavells (Cat No.JETAIRISFLS120WLED757ASYMLTG) / \nCrompton (Cat No.LFLN-120-CDL/60) / \nPhilips (Cat No. BVP192LED110 CW HO NB FG GR PSU) 8 Each
76 10.57 M&L for construction of brick masonary Valve Pit (wall thickness 230mm) having internal dimension 600mm x 600mm x600mm including necessary earth work , 100mm thick P.C.C. (1:3:6 Type C2) as in foundation, brick work in cement morter 1:6, 15mm thick plastering in cement morter 1:4 both in entire internal & external surfaces (upto 15cm below ground level), 3.15mm M.S. sheet cover duly hinged with M.S. angle framework made with M.S. angle of size 40mmx40mmx5mm with locking facility. The M.S. part shall be painted with two coats of Black Bitumenous paint over a coat of Red Oxide Metal Primar and Two Coats of Limewash shall have to be done on the exposed surfaces of the brick work . 2 Each
77 10.58 S&F Monoblock type Centrifugal Pump Set of capacity 10 hp, suitable for operation with AC 3 Phase,415 Volts, 50 Hz supply.\n\nMake : KIRLOSKAR BROTHERS ( Model :KDS 1040 +) \nor Equivallent Model in CRI / CROMPTON 1 Each
78 10.59 S&F Brass / Bronze Check Valve , 50 mm bore, screwed for fixing with GI Pipe complete all as specified and directed. 1 Each
79 10.6 S&F Wall Mounted Fully AutomaticStar-Delta motor starter, suitable for 10 hp motor and to be operated with 3 Phase, 415 volts, 50 Hz AC supply, duly grouted and flush mounted in wall and comprises with the followings :-\na) Heavy duty 4 Pole Contactor of suitable rating.\nb) Over Load Relay of suitable range.\nc) Auto Start Switch\nd) 3 Position Selector Swich for SPP Auto / SPP Manual / Manua\ne) Analog Type Volt Meter with selector switch\nf) Supressed Scale Ammeter\ng) R-Y-B LED Indicator Lamp\nh) Motor ON & TRIP LED Indicator Lamp\ni) 3 Pole MCB 'C' Curve of suitable rating for short circuit protection\n\nMake : Controls & Switchgear (Cat No : BE3-SPSDDX204Q321)\nOR \nEquivallent Model in L&T / BCH / SIEMENS\n 1 Each
80 10.61 M & L for Construction of Septic Tank for 10 users designed to carry sewage and sullage water, including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab having 8 mm dia TMT bar reinforcemement @ 75 mm c/c & 6 mm thick mild steel plate embedded all around of cover slab , 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber , form work to sides and soffits, 150 mm dia SGSW inlet & out let pipes up to 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, with effective depth of 1.5 meter and overall depth of 3 meter for 10 users complete all as shown on drawings and as specified & directed by Eng-in-Charge. 1 Each
81 10.62 M & L for Construction of Soakage well for 1.20 m dia( internal dia ) & 3.00 m effective depth including necessary excavation in earth work in any type of soil , plain cement concrete 1:3:6 type C-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 in walls & honey combed brick wall , reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast cover slab having 8 mm dia TMT bar reinforced/ SFRC cover, interconnecting pipes of RCC , plain cement concrete band and dwarf wall, form work to sides and soffits of RCC slab & filling with brick bats of size 1.2m dia x 3 m effective depth loose filling complete complete all as specified and shown in drawings. 1 Each
82 10.63 Dismantling of concertina coil of any size complete all as specified and directed 11 Per 100 RM
83 10.64 S&F in diamond shape high strength steel punched tape concertina coil 600mm dia (in specified and standard stretched position) hot dip galvanized coated with CLR anti corrosive paint by making diamond shape with the help of dove tail clips (18 swg) fixed over razor wire with the help of hog rings(14 SWG) in angle iron bracket/frame over boundary wall etc complete all as specified and as directed. (Note: Razor wire and angle iron frame/bracket shall be measured and paid seperately) 2200 RM
84 10.65 M&L for earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI wire of size 4 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 15 mm dia GI pipe "medium grade" for protection of earth lead and connected to Neutral point of Transformer / Voltage Stabilizer etc, or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50 mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed.\n(To be used for pole earthing) 5 Set
85 10.66 M&L for earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI strip of size 32 x 6 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "medium grade" for protection of earth lead and connected to Neutral point of Transformer / Voltage Stabilizer etc, or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50 mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed.\n(To be used for Equipment earthing) 18 Each Job
86 10.67 Services for Comprehensive maintenance, operation and repair of Solar power plant for 24 months / 730 days (including one year defect liability period) in one shift including Saturday, Sunday & holidays after completion of project as per conditions of contract including the following :- \n
87 10.68 First 11 Months 1 Each\nJob
88 10.69 Second 11 Months 1 Each\nJob
89 10.7 Third 11 Months 1 Each\nJob
90 10.71 Fourth 11 Months 1 Each\nJob
91 10.72 Fifth 11 Months 1 Each\nJob
92 10.73 Outsourcing services for Comprehensive maintenance, operation and repair of Solar power plant for 55 months (including one year defect liability period) in two shifts including Saturday, Sunday & holidays after completion of project as per conditions of contract including the following :- \n
93 10.74 (i) The Work order for outsourcing of services shall be placed for eleven months & no price adjustment for its extension shall be permissible. The Solar Power Plant shall be operated in 02 shifts per day unless otherwise directed by the Engr-in-charge/GE. Necessary recovery will be made for non operation of plants shift wise on prorata basis of quoted rates of the item. Recovery rate shall be double the rate quoted by the bidder for each shift & shall be final & binding. \n
94 10.75 (ii) The contractor shall deploy minimum tradesman as follows :- \n(aa) One trained Electrician and one helper in each shifts for attending/ monitoring the breakdown and preventive maintenance.
95 10.76 (iii) The electrician must have ITI in Electrical and having experience of 02 Years in operation & maintenance of solar power plant and familiar with SCADA operating system, weathering monitoring system, HT/LT installation and security and safety features complete. The Necessary technical qualification certificate shall be produced for verification of Engr-in-charge & get the written approval on record before deploying for works. (iv) Contractor shall offer service for entire system as per maintenance schedule as directed by GE in presence of Engineer in charge/JE and maintain necessary record for the same.\n
96 10.77 (v) Contractor shall also ensure the following :-\n(aa) Servicing of all solar equipment’s, HT / LT control system, Transformers weather monitoring equipment’s, SCADA system etc all as per OEM recommendations. \n (ab) Cleaning of Solar PV modules by washing, sprays, brushes, tools and plants, any washing solutions as per OEM recommendations & as per laid down norms for solar power plant complete all as directed by the Engr-in-charge/GE.\n(ac) Checking of ABT meter reading and recording in log book as per instruction given by Engr-in-Charge.\n(ad) The Engineer/Electrician shall submit reports in soft and hard copy format as required by the Engineer in Charge.\n(ae) Safety, security of all E&M equipment’s, solar panels, T&P and Sub Station complete all as directed by the Engineer-in-charge.\n(af) Area cleaning removing of grasses, bushes etc as per the instructions of Engr-in-Charge.
97 10.78 (vi) Arrangement of all required work, access permissions shall be made available to work force of the contractor by the GE through Security Officer.
98 10.79 (vii) Repairing of all installation if required will be carried out on site or at service centre. Quoted rates shall be all inclusive and includes for required Spares, services, labour, handling and transportation charges etc.
99 10.8 (viii) Proper & efficient functioning of the plant must be ensured through regular inspection by qualified engineer of MNRE approved vendor of Category 'A' bi-monthly.
100 10.81 (ix) Contractor shall arrange training one month for operation and maintenance to MES tradesman as directed by GE.
101 10.82 Note :- All stationery, T&P, items required to maintain the installations in a presentable manner and to keep plant in 100% functionable condition are deemed to be included in the cost of quoted rate.