Purchase Of Disposable Items For Cardiac Anaesthesiology Deptt. On Two Years Rate Contract Basis, CNC AIIMS, NEW DELHI-Delhi

All India Institute Of Medical Sciences-AIIMS has published Purchase Of Disposable Items For Cardiac Anaesthesiology Deptt. On Two Years Rate Contract Basis. Submission Date for this Tender is 27-04-2020. Abrasive and Abrasive media Tenders in CNC AIIMS, NEW DELHI Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

23862160
Corrigendum : Purchase Of Disposable Items For Cardiac Anaesthesiology Deptt. On Two Years Rate Contract Basis
National Competitive Bid
Indian
Delhi
CNC AIIMS, NEW DELHI
27-04-2020

Tender Details

Purchase Of Disposable Items For Cardiac Anaesthesiology Deptt. On Two Years Rate Contract Basis - 2 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size:5.0 Mm 3 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size:5.5 Mm 4 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size: 6.0 Mm 5 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size:6.5 Mm 6 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size:7.0 Mm 7 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size: 7.5 Mm 8 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size: 8.0 Mm N 9 Tracheostomy Tube ( Cuffed ) - N• Tracheostomy Tube Cuffed With Introducer N• Provided With Holed Inner Cannula For Easy Insertion Of Guide Wire N• Tapered Tip For Easy Passage N• Low Pressure Cuff N• Size Of The Tube Mentioned On The Flange N• Adjustable Hange N• Tape For Fixation N• Size:8.5 Mm 10 Latex Free Ecg Electrodes: N• White Foam Type, Centred Snap With Specially Formulated Solid Ag / Agcl Gel. N• Hypo Allergic Adhesive, Latex Free, Non Irritant. 11 Multiport Airway Adaptor: N• Silicone Capped Connectors For Bronchoscopy N• Silicon Diaphragm To Allow Insertion Of Bronchoscope Or Suction Catheter N• Connection To Endotradeal Tube And Ventilator 12 Mount Catheter Flip Tap Ncollapsible Corrugated Tube Manufactured Of Polyethylene Material Ndouble Flip Tap Cap With Diameter Of Silicone Port = 3.4 Mm And Of Suction Port = 9.4 Mm N22 Mm Female Connector Is Compatible With All Breathing &Ventilator Circuits Ninert To All Anaesthetic Gases & Reagents 13 Hourly Urine Measurement Bag – Size: 500 Ml N N• Hourly Urine Measurement Collection Bag Consists Of 500 Ml Clear & Transparent Measured Volume Chamber Divided In Four Partitions Of 50Ml, 200Ml, 350Ml & 500 Ml. N• Each Partition Can Be Drained Both Individually And Collectively N• 2 Ltr Urine Collection Bag With Bottom Drain Outlet N• 150 Cm Long Kink Resistant Tubing With Corrugated Protector. N• Mid Stream Closed Urine Culture Sample Port Must Be Provided In Tapered Connector Making It A Completely Close Circuit Eliminating Risk Of Infection. N• 2 Rubber Straps Provided For Bed Side Hanging. 14 Hourly Urine Measurement Bag: – Size: 250 Ml N N• Graduated Transparent Measured Volume Chamber 250 Ml. N• Fully Closed Circuit Drainage N• 2 Ltr Urine Collection Bag With Bottom Drain Outlet N• 150 Cm Long Kink Resistant Tubing. N• Foldable Hanger With Tube Holder N• Sterile, Individually Packed. N 15 Hourly Urine Measurement Bag – Size: 100 Ml N• Graduated Transparent Measured Volume Chamber 100 Ml. N• Fully Closed Circuit Drainage N• 2 Ltr Urine Collection Bag With Bottom Drain Outlet N• 150 Cm Long Kink Resistant Tubing. N• Foldable Hanger With Tube Holder N• Sterile, Individually Packed. N 16 Disposable Patient Wipes: N• Size: 300 Mm X 240 Mm Spunlacenon Wovenfabric Sheet. N• Soaked In A Solution Consists Of Chlorohexidinegluconate, Propylene Glycol, Dimethiconecopolyol, And Other Ingredients Along With Aloe Vera, Glycerin, Hydrogenated Castor Oil, Fragrance And Citric Acid / Tea. N• Alcohol Free N• Pack Size: Of 10 Pcs. N 17 Nanofiber Mask: Nhigh Efficiency Nanofiber Filter Mask, Retains Particulate Matter Above 0.3 Micron N• Ergonomically Designed For A Comfortable Fit And Ensures Complete Fitment On The Face To Prevent Any Leakage. N• Anti-Smoke, Anti-Dust, Anti-Pollen, Anti-Fog, Anti-Haze. N• Prevent Allergens Associated With Pollens, Dust, Mites, Etc. N• High Filtration Efficiency Combined With Low Resistance N• Individually Packed In A Lock Pouch Pack With Tear Open Slot. N 18 Corrugated Oxygen Connector: N• A Specially Designed Kit With T For Oxygen Delivery N• 15 Mm Connector N• Suction Port At The Elbow N• 2 Meter Star Lumen Oxygen Tube N• Open Distal End N• Sterile, Individually Packed 19 Eye Shield Fog Free Mask With Visor: N• It Should Be Consisted Fog-Free Multilayer With Visor N• It Should Be Made Of Pleat-Style With Ties. N• It Should Have High Fluid Resistance Capability. N• It Should Have Particulate Filtration Efficiency More Than 99% N• It Should Have Bacterial Filtration Efficiency More Than 99%. N 20 Endobronchial Tube- Double Lumen N• Robert Shaw Tube, Double Lumen With Two Cuffs N• Anatomically Correct Curvatures N• High Volumes, Low Pressure Tracheal Cuff N• Colour Coded Pilot Balloons With Luer Lock Connector, Marked With The Name Of The Lumen N• D Shaped Lumina N• Double Swivel Connections With Double Caps N• Suitable For One Lung Ventilation N• Right Sided Et Tube Nsizes :- 28Fg N 21 Endobronchial Tube- Double Lumen N• Robert Shaw Tube, Double Lumen With Two Cuffs N• Anatomically Correct Curvatures N• High Volumes, Low Pressure Tracheal Cuff N• Colour Coded Pilot Balloons With Luer Lock Connector, Marked With The Name Of The Lumen N• D Shaped Lumina N• Double Swivel Connections With Double Caps N• Suitable For One Lung Ventilation N• Right Sided Et Tube Nsizes :- 32Fg N 22 Collapsible Breathing System With 2 Ltr Bag: N• Corrugated, Flexible And Lightweight Tubing N• Standard Connectors N• Sterile, Latex Free N• 2 Ltr. Bag, 22Mm Tube, 2 Mtr. & 1.5 Mtr Limb. N 23 Collapsible Breathing System With 3 Ltr. Bag N• Corrugated, Flexible And Lightweight Tubing N• Standard Connectors N• Sterile, Latex Free N• 3 Ltr Bag, 22Mm Tube, 2 Mtr& 1.5 Mtr Limb N 24 Ez Blocker: N• 2 Distinct Proximal Balloons For Inflation N• 7Fr. Bifurcated Distal End ( Y Shaped ) N• High Volume Low Pressure Cuff N• Adaptor With Scope Lid N• Oxygen Adaptor N• Depth Markers N• Central N 25 Collapsible Breathing System 2 Mtr. With Elbow N• Corrugated, Flexible And Lightweight Tubing N• Standard Connectors N• Sterile, Latex Free 22Mm Tube, 2 Mtr, With Luerelbo N 26 Collapsible Breathing System 3 Mtr With Elbow: N• Corrugated, Flexible And Lightweight Tubing N• Standard Connectors N• Sterile, Latex Free N• 22Mm Tube, 3 Mtr, With Luer Elbow N 27 Iv Set With Flow Controller With Luer Lock ( Dehp Free ) N• Manufactured From Dehp Free Medical Grade Material, Free From Phthalates. N• Sharp Vented Spike Set With 1.2 Micron Air Vent N• Dehp Free Drip Chamber With 1.5 Micron Disc Filter. N• Latex Free Resealing Type ‘Y’Injection Port For Extra Medication N• Advance Rotating Luer Lock At Distal End N• Should Have Prime Stopper / Air Stopper Membrane. 28 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable N• Size : 0 N 29 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable Nsize : 1, N 30 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable N• Size : 2 N 31 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable N• Size : 3 N 32 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable N• Size : 4 N 33 Silicone Mask For Resuscitator N• Spare Silicone Mask For Resuscitator N• Autoclavable N• Size : 5 N 34 Iv Extension With Flow Controller: N• I V Extension Line With Precision Rotating Type Controller N• Y –Site And Male / Female Luer Lock. N 35 Pvc Free O2 Mask N• ( A ) Size : Adult N• Soft Seal, Double Moulded, Pvc Free O2 Mask N• No Unpleasant Odour N• Cushion Provides Better O2 Concentration N• Leaves Little Air Blind Angle N• No Metal Nose Clip Making It Mri Compatible 36 Pvc Free O2 Mask N Size: Child N• Soft Seal, Double Moulded, Pvc Free O2 Mask N• No Unpleasant Odour N• Cushion Provides Better O2 Concentration N• Leaves Little Air Blind Angle N• No Metal Nose Clip Making It Mri Compatible 37 Pvc Free Aerosol Mask Nsize : Adult N• Soft Seal, Double Moulded, Pvc Free Aerosol Mask N• Medical Grade Pp Material N• No Unpleasant Odour N• Cushion Provides Better Seal, Reducing Medicine Wastage N• Leaves Little Air Blind Angle N• No Metal Nose Clip Making It Mri Compatible 38 Pvc Free Aerosol Mask: N• Size: Child N• Soft Seal, Double Moulded, Pvc Free Aerosol Mask N• Medical Grade Pp Material N• No Unpleasant Odour N• Cushion Provides Better Seal, Reducing Medicine Wastage N• Leaves Little Air Blind Angle N• No Metal Nose Clip Making It Mri Compatible 39 Multigang Manifold N N• Polycarbonate Body N• Ergonomic, Low Torque Acetyl Handle N• Easy Grip, Smooth Rotation 40 Mapelson D System N N• A Co-Axial Modification Of The “T”-Piece System N• Convenient, Lightweight Anesthesia Delivery System. N• Based On Mapleson “D” System, Provided With A Corrugated Tube, Expiratory Valve And Antistatic Bag 2 Ltr. N• 22 Mm Cap, 22Mm Corrugated Tube, 1.6Mtr, 22 Mm Expiratory Valve N• Standard Connectors, With Low Dead-Space. N• Sterile And Individually Packed. 41 Mapelson F System: N• Convenient, Lightweight Anesthesia Delivery System. N• Based On Mapleson “F” System, Provided With 15Mm And 10Mm Corrugated Tube, Expiratory Valve And Antistatic Bag 0.5 Ltr, Rebreathing Bag And Bag Bleed Valve. N• 22 Mm Cap, 15Mm Corrugated Tube, 0.42Mtr And 10Mm Corrugated Tube, 2Mtr, Expiratory Valve N• Standard Connectors, Extra Circuit Adapters N• Sterile And Individually Packed N 42 Hi Fio2 Mask N• Specially Designed For High Concentration Oxygen Therapy. N• Soft, Transparent And Odor Free Mask. N• Smooth, Feathered Edges For Patient Comfort. N• Mask Fits Snugly Over The Patient’S Mouth And Nose. N• Adjustable Elastic Strap To Fit Over The Patient’S Head. N• 600 Ml Reservoir Bag. Non-Return Valves Provided At Inhale And Exhale Points To Prevent Carbon-Dioxide Retention. N• Light Weight Reservoir Improves The Oxygen Efficiency. N• Individually Packed N 43 B T Set With Luer Lock N• Blood Transfusion Set With Lure Lock. N• Long Drip Chamber, 200Μm Filter, To Prevent Any Blood Clots In Passage. N• Additional Injection Port. N• Roller Controller For Adjustment Of Transfusion Rate. N• Smooth 150 Cm Long, Kink Resistant Tube. N Sterile, Disposable, Non-Pyrogenic, Individually Npacked N 44 Enteral Feeding Bag ( Dehp Free ) :- N• Enteral Feeding Bag Intended For Gastro-Intestinal Feeding. N• 1.2 Litre Capacity Bag. N• Ice Pouch Is Provided On The Rear Side Of The Bag For Preserving The Food For Longer Intervals Of Time. N• Transfer Set Is Directly Connected To The Bag. N• Roller Controller Provided On The Transfer Set Facilitates Control On The Administered Feed. N• The Feeding Bag Is Graduated To Determine Precisely The Quantity Of The Administered Feed. N• Feeding Bag Is Provided With A Closure Cap And Also A Hanger For Safe Hanging During And After Use. N• Sterile, Individually Packed In Peelable Pouch. 45 Disposable Syringe With Needle Luer Lock -Size 2 Ml N• Manufactured From Medical Grade Virgin Polypropylene. N• Threaded Luer Lock Tip Designed For Safefit Connection To Female Connector N• Prominent Graduation Ensures Dosage Accuracy. N• Clear Transparent Barrel. N• Rubber Tipped Piston N• Thermoplastic Elastomer Gasket Is Inert That Provides Minimum Friction During Movement And Prevents Leakage And Back Flow. N• Sharp Triple Facetted Beveled Tip Needle. N• Sterile, Disposable, Non-Pyrogenic, Individually Packed. N 46 Disposable Syringe With Needle Luer Lock- Size 5 Ml N• Manufactured From Medical Grade Virgin Polypropylene. N• Threaded Luer Lock Tip Designed For Safefit Connection To Female Connector N• Prominent Graduation Ensures Dosage Accuracy. N• Clear Transparent Barrel. N• Thermoplastic Elastomer Gasket Is Inert That Provides Minimum Friction During Movement And Prevents Leakage And Back Flow. N• Rubber Tipped Piston N• Sharp Triple Facetted Beveled Tip Needle. N• Sterile, Disposable, Non-Pyrogenic, Individually Packed. N 47 Disposable Syringe With Needle Luer Lock -Size 10 Ml N• Manufactured From Medical Grade Virgin Polypropylene. N• Threaded Luer Lock Tip Designed For Safefit Connection To Female Connector N• Prominent Graduation Ensures Dosage Accuracy. N• Clear Transparent Barrel. N• Thermoplastic Elastomer Gasket Is Inert That Provides Minimum Friction During Movement And Prevents Leakage And Back Flow. N• Rubber Tipped Piston N• Sharp Triple Facetted Beveled Tip Needle. N• Sterile, Disposable, Non-Pyrogenic, Individually Packed. 48 • Disposable Syringe With Needle Luerlock N• Size: 20 Ml. N• Manufactured From Medical Grade Virgin Polypropylene. N• Threaded Luer Lock Tip Designed For Safefit Connection To Female Connector N• Prominent Graduation Ensures Dosage Accuracy. N• Clear Transparent Barrel. N• Thermoplastic Elastomer Gasket Is Inert That Provides Minimum Friction During Movement And Prevents Leakage And Back Flow. N• Sharp Triple Facetted Beveled Tip Needle. N• Sterile, Disposable, Non-Pyrogenic, Individually Packed. N• Rubber Tipped Piston N 49 Disposable Syringe Without Needle Luer Lock N- Size 50 Ml N• Manufactured From Medical Grade Virgin Polypropylene. N• Threaded Luer Lock Tip Designed For Safefit Connection To Female Connector N• Prominent Graduation Ensures Dosage Accuracy. N• Clear Transparent Barrel. N• Thermoplastic Elastomer Gasket Is Inert That Provides Minimum Friction During Movement And Prevents Leakage And Back Flow. N• Sterile, Disposable, Non-Pyrogenic, Individually Packed. N• Rubber Tipped Piston. N 50 Stainless Steel Prep Razor: N• Stainless Steel Prep Razor With Platinum Edge Blade With Teflon Coating N• High Standard Of Safety And Hygiene For Pre-Operational Procedures N• Safety Cap For Safety To The Handler Pre & Post Procedure N• Comb Located Close To The Blade, To Lift The Soft Hair N• Ribbed Handle Ensures A Steady And Efficient Grip On The Razor N• Smoothly Follows The Natural Contours Of The Body N• Sterile Eo, Packed Individually. N 51 Volumetric Burette Set 150 Ml N• Soft, Large Caliberated, Flexible Burette Chamber Manufactured From Pematerial, Suitable For Most Of The Pharmaceutic Fluids. N• Sharp Piercing Vented Spike Provided With Built-In Air Inlet With Bacterial Barrier Filter. N• Micro Drip Set Size Of 60 Drops / Ml. N• Easy To Read Scale With White Contrast Background. N• Luer Tip To Prevent Easy Disconnection Lock N• Additional In-Line Injection Port. N• Drip Rate Controller With Fail Safe Mechanism N• Floating Auto Shut-Off Valve Acts As Volume Indicator And Automatically Shuts Off The Path To Prevent Air Embolism. N• “Y” Injection Site For Additional Medication. N• Patented Design, No-Kink Device Prevents Kinking Of Tube. N• Sterile, Individually Packed. N 52 Under Sheet Padsterile: N• Soft Non-Woven Top Sheet With Heavy Duty Absorbency. N• Tear Resistant, Slip Resistant, Waterproof Pe Back Sheet For Leakageprevention. N• Super Absorbent Polymer Evenly Spread To The Core With Sealed Edges. N• High Absorbent Tissue Filled Centre In The Pad To Lock The Fluid Immediately. N• Quilted Mat For Better Fluid Dispersion. N• Size: 60 X 90Cm. N• Strerile, Individually Packed N 53 Flexible Tubing - 100% Silicone ( Sterile ) - 6Mm N• Highly Flexible Medical Grade 100% Silicone Tubing, N• Withstand Temperature From - 85 Degree Celsius To 250 Degree Celsius. N• Sizes : 6Mm , Length 6 Mtr N• Sterilized By Eo, Individually Packed N 54 Flexible Tubing - 100% Silicone ( Sterile ) - 8Mm N• Highly Flexible Medical Grade 100% Silicone Tubing, N• Withstand Temperature From - 85 Degree Celsius To 250 Degree Celsius. N• Sizes : 8Mm , Length 6 Mtr N• Sterilized By Eo, Individually Packed 55 Air Mattress Bubble Pad And Pump: N• Air Mattress To Prevent Bedsores N• Kit Consists Of 1 Motor Pump, 1 Air Bubble Mattress & 1 Repair Kit N• Portable And Light Weight Motor N• Sleek Body With A Low Sound Pump N• Air Output = > 4.5 Ltr / Min, Cycle Time = 12 Min N• Pvc Pad Consist Of 130 Bubble Cells N• Dimensions : 280Cm ( L ) , 90Cm ( W ) , 6.5Cm ( H ) N 56 Nasojejunal Tube:- N• Metallic Stylet Inside The Tube To Be Provided To Facilitate The Intubation & Accurate Placement. N• Polyurethane Enteral Tube N• Inert And Non-Reactive To Gastric Juices. N• Dual Port Connector Facilitates The Use Of Catheter Mount Syringe As Well As Luer Fitment Of Syringe. N• 2 Lateral Eyes For Efficient Administration & Aspiration. N• The Tube Is Marked At Different Intervals Of 20, 40, 60, 80 And 100 Cm From The Tip Along The Tube Length For Accurate Placement. N• Color Coded For Instant Size Identification N• Open Tip For Easy Placement N• Size: Length 130 Cm 12Fg Nsterile, Packed In Peel Open Pack N 57 Nasojejunal Tube:- N• Metallic Stylet Inside The Tube To Be Provided To Facilitate The Intubation & Accurate Placement. N• Polyurethane Enteral Tube N• Inert And Non-Reactive To Gastric Juices. N• Dual Port Connector Facilitates The Use Of Catheter Mount Syringe As Well As Luer Fitment Of Syringe. N• 2 Lateral Eyes For Efficient Administration & Aspiration. N• The Tube Is Marked At Different Intervals Of 20, 40, 60, 80 And 100 Cm From The Tip Along The Tube Length For Accurate Placement. N• Color Coded For Instant Size Identification N• Open Tip For Easy Placement N• Size: Length 130 Cm 14 Fg N• Sterile, Packed In Peel Open Pack N 58 Nasojejunal Tube:- N• Metallic Stylet Inside The Tube To Be Provided To Facilitate The Intubation & Accurate Placement. N• Polyurethane Enteral Tube N• Inert And Non-Reactive To Gastric Juices. N• Dual Port Connector Facilitates The Use Of Catheter Mount Syringe As Well As Luer Fitment Of Syringe. N• 2 Lateral Eyes For Efficient Administration & Aspiration. N• The Tube Is Marked At Different Intervals Of 20, 40, 60, 80 And 100 Cm From The Tip Along The Tube Length For Accurate Placement. N• Color Coded For Instant Size Identification N• Open Tip For Easy Placement N• Size: Length 130 Cm 16 Fg N• Sterile, Packed In Peel Open Pack 59 Day & Night Bag For Incontinence: N• Suitable For Day & Night Use For Incontinence. N• Patented Urovision Chamber With Complete Closed Drainage System Which Eliminates The Risk Of Cauti N• Available With T Type Bottom Outlet. N• Manufactured From Soft Clinical Grade Pvc Sheeting N• Diaphragm Valve To Prevent The Backflow N• Printed With Easy To Read Scale N• Universal Connector With Mid-Stream Sample Port N• Foldable Hanger To Hold Provision Chamber 60 100% Silicone External Catheter: N• Soft Silicone Male External Catheter. N• Non Irritating, Non Reactive Transparent Material N• Skin Friendly Adhesive N• Cup Shape Applicator N• Provided With Soft Adhesive Strip N• Ergonomically Shaped N• Sterile And Individually Packed N• Sizes: 20 Mm 61 100% Silicone External Catheter: N N• Soft Silicone Male External Catheter. N• Non Irritating, Non Reactive Transparent Material N• Skin Friendly Adhesive N• Cup Shape Applicator N• Provided With Soft Adhesive Strip N• Ergonomically Shaped N• Sterile And Individually Packed N• Sizes: 25Mm, N 62 100% Silicone External Catheter: N N• Soft Silicone Male External Catheter. N• Non Irritating, Non Reactive Transparent Material N• Skin Friendly Adhesive N• Cup Shape Applicator N• Provided With Soft Adhesive Strip N• Ergonomically Shaped N• Sterile And Individually Packed N• Sizes: 30Mm N 63 100% Silicone External Catheter: N• Soft Silicone Male External Catheter. N• Non Irritating, Non Reactive Transparent Material N• Skin Friendly Adhesive N• Cup Shape Applicator N• Provided With Soft Adhesive Strip N• Ergonomically Shaped N• Sterile And Individually Packed N• Sizes: 35Mm N 64 Tri Extension Needle Free Connector N• Needle Free I.V Connector With Triple Extension For Running Three Lines Nsimultaneously With Rotating Luer Slip Lock And Three Clamps. N• Sterile, Blister Pack. N• Low Prime Volume: 0.90 Ml 65 Quadro Extension Needle Free Connector N N• Needle Free I.V Connector With Quadraple Extension For Running Four Lines Nsimultaneously With Rotating Luer Slip Lock And Four Clamps. N• Sterile, Blister Pack. N• Low Prime Volume: 1.20 Ml 66 Mapleson F Jackson Rees Modification N• Good Quality N• Light Weight N• Non-Conductive Disposable Pvc Plastic, T-Piece With Corrugate Tubing N• 1.8 M Circuit Length N• Low Resistance N• 500Ml Bag With Apl Valve With 15F / 22F Connector. N 67 Smoothbore Circle Breathing 22F N• Good Quality N• Light Weight N• Non-Conductive Disposable Pvc Plastic N• Flexible / Light Weight Rigid Connections N• 1.6M Long N• Extra Limb 1.6M Long N• 22F Rebreathing Bag N• Safety Cap N 68 Circle Breathing ( 15F ) N• Good Quality N• Light Weight N• Non-Conductive Disposable Pvc Plastic N• Flexible / Light Weight Rigid Connections N• 1.6M Long N• Extra Limb 1.6M Long N• 22F Rebreathing Bag N• Safety Cap N 69 Breathing Tube Holder For Adult Circuits N• Universal Tube Holder To Support Breathing Circuit N• Light Weight & Adjustable At Various Angles With One Joint And Under Mat Fixation N• Adjustable Height N• For Adult 70 Breathing Tube Holder For Paediatric Circuits N• Universal Tube Holder To Support Breathing Circuit N• Light Weight & Adjustable At Various Angles With One Joint And Under Mat Fixation N• Adjustable Height Nfor Paediatrics N 71 Breathing Tube Holder For Neonatal Circuits N• Universal Tube Holder To Support Breathing Circuit N• Light Weight & Adjustable At Various Angles With One Joint And Under Mat Fixation N• Adjustable Height Nfor Neonates N N 72 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 1 N 73 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 1.5 N 74 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 2 N 75 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 2.5 N 76 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 3 N 77 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 4 N 78 Supraglottic Airway ( I-Gel ) N• Airway Device Without An Inflatable Cuff N• Incorporated Epiglottis Blocker N• With Gastric Channel N• With Bite-Block N• Sizes: 5 N 79 Flexible Tip Laryngoscope: N• Flexible Tip Macintosh Fo Laryngoscope With A Tip Adjustable Through 70 Degree N• A Lever Controls The Tip Angle N• Both Ends Of Large Fibre Bundle Whould Be Protected N• Fits All Iso Fo Handles ( Green Handles ) N• All Blades Made Of Premium Grade Stainless Steel In Matt Finish N• Should Be Autoclavable N• Complete With Mac Blades Sizes:1, 2, 3 And 4, With Handle N 80 Breathing System For Closed Anesthesia: N• 1.Should Be 1.6M Long Disposable N• 2.Should Be Made Of Antimicrobial Silver Material N• 3.Should Have An Extra 0.8M Limb N• 4.Should Have 2Ltr Rebreathing Bag N• 5.Should Have Facility To Deliver Nebulisation, Without Detaching The Patient. N 81 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Extra Small 82 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Small N 83 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Medium N 84 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Large 85 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Extra Large 86 Niv Helmets: N• Made Of Biocompatible Plastic Material N• Connectors-22M / 22F N• Armpit Fastening Straps N• Two Sealed Access Ports For Catheters From 3.5-7.0Mm N• Fitted With Bi-Directional Anti-Asphyxia Valve N• Airtight Patient Access Port With Screw Cap N• Light Weight And Transparent N• Usable In Both Standing & Supine Position N• Latex Free N• Sizes: Extra Extra Large N 87 Oral Care Brush: N• Out Of Package, Ready To Use N• Moulded Bristles N• Flexible Neck To Ensure Reduced Force N• Small Head And Long Neck To Easily Reach Target N• Suction Holes On Top And Between The Bristles N 88 Fluid Shield N95 Mask N• Fluidshield* N95 Filter Respirators Are Niosh0 Approved And Are Designed To Provide An Effective Facial Fit As Required For Proper Respiratory Protection. Niosh Approved4-Layer Construction Soft Inner Lining 100% Natural Rubber Latex-Free. Available With Safety Seal. N 89 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes 0 N• Truly Anatomical With Unique Flexible Seal N• Truly Anatomical With Unique Flexible Seal N 90 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes:1 N• Truly Anatomical With Unique Flexible Seal Ntruly Anatomical With Unique Flexible Seal N 91 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes:2 N• Truly Anatomical With Unique Flexible Seal Ntruly Anatomical With Unique Flexible Seal N 92 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes:3 N• Truly Anatomical With Unique Flexible Seal Ntruly Anatomical With Unique Flexible Seal N 93 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes:4 N• Truly Anatomical With Unique Flexible Seal Ntruly Anatomical With Unique Flexible Seal N 94 Antistatic Anatomical Masks N• Autoclavalveatleast 100 Times N• Latex Free N• Antistatic N• Made Up Of Natural Rubber N• Sizes:5 N• Truly Anatomical With Unique Flexible Seal Ntruly Anatomical With Unique Flexible Seal N 95 Anti Microbial Breathing System Heated Wire: N• Is A Light Weight And Flexibeto Minimize Drag On Circuits, 1.5M Heated Inspiratory Tubing, Silver Impregnated, 0.5M Humidifier Connection Tube, Auto Float Humidification Chamber With Dual Float Sizes: Pediatric, N 96 Anti-Microbial Breathing System Heated Wire: Nis A Light Weight And Flexibeto Minimize Drag On Circuits, 1.5M Heated Inspiratory Tubing, Silver Impregnated, 0.5M Humidifier Connection Tube, Auto Float Humidification Chamber With Dual Float Sizes: Neonatal N 97 Patient Transfer Slide: N• Should Be Light Weight N• Able To Transfer Between A Bed And X-Ray Table, Operating Table, Ambulance Stretcher. N• Patient Transfer Slide Should Be Full Body N• Material Should Be Nylon N• Should Be Foldable From Middle N• Total Weight Of The Slide Should Not Be More Than 3Kg N• Up To 200Kg Patient Can Be Transferred By A Single Person N• Chemical Resistant Material N• It Should Be Disinfected By Surface Disinfectant N• Upper Part Should Rotate And Lower Part Should Slide N• Size 89X55 Cm ( +=3% ) 98 Mapleson C-Circuit N• Light Weight Transparent For Use In Induction Of Anaesthesia, Resuscitation Patient Transport. N• 2.0 Ltrs.Rebreathing Bag With Adjustable Pressure Limiting Valve At Patient’S End. N• To Provide Adaptor For Direct Connection To Flow Meter. N 99 Sodalime 5Kg. Jerry Can N N• Suitable For Use With Anaesthetic Breathing Systems N• To Meet All Requirement Of Unites States Pharmacopoeia ( Usp ) N• Exhaustion To Clearly Indicate The Colur Change ( While To Purple ) N• To Contain Less Sodium Hydroxide N• Packed In Jerry Cans For Longer Lasting / Easy Storage, Iso Certified N• No Powder, Minimum Resistance, Hard Surface, Greater Absorption N N80 Boxes / Njerry Of 5Kg Each N 100 Bain Coaxial Antimicrobial Mapleson D With Leak Tester Device N• Disposable Good Quality Light Weight. N• Silver Nitrate Impregnated N• Internal Volume 500 Ml N• With 2 Litre Rebreathing Bag Nwith Leak Tester Device Extra Long Coaxial Mapleson D System N 101 Extra Long Coaxial Mapleson D System N• Disposable Good Quality, Light Weight N• Internal Volume 2000Ml N• With 2 Litre Rebreathing Bag N• With Leak Tester Device N• For Anaesthesia In Ct Scan Units And Mri Suits N 102 Tpiece With Reservoir Bag And Tubing N• T Piece With Reservoir Bag For Visual Indication N• Able Connect To Ett / Tt N• With O2 Tubing N• Reservior Bag <500Ml 2 Litre N 103 Filter Mask N• Incurved Face Seal N• Integral Filter Media To Prevent Aerosol Escaping N 104 Flat Operation Table Pad Universal N N• Operating Theatre Table Pad Should Have A Minimum Thickness Of 12Mm. N• Dimension Of Ot Pad Should Comply With Minimum Length X Breadth Of 500 X500mm. N• It Should Have Flat Type Single Phase Continuous Surface At All Along Body Length. N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete N• Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact N• It Should Be Organic Inert Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N 105 Flat Operation Table Pad Universal N N• Operation Theatre Table Pad Should Have A Minimum Thickness Of 12Mm N• Dimensions Of Ot Pad Should Comply With Minimum Length X Breadth Of 900 X 500Mm. N• It Should Have Flat Type Single Phase Continuous Surface Along Half Of Body Length. N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferable Less Than Fraction Of Second N 106 Flat Operation Table Pad Universal N N• Operation Theatre Table Pad Should Have A Minimum Thickness Of 12Mm N• Dimensions Of Ot Pad Should Comply With Minimum Length X Breadth Of 1150X500mm N• It Should Have A Single Phase Continuous Surface With Maximum Pressure Redistribution Preventing Bed Sores All Along Body Length. N• It Should Have Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement. N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact. N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage. N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second. N 107 Open Head Ring Adolescent Size: N N• The Positioning Device Should Have Donut ( Hole ) At The Centre With A Minimum Inner Diameter Of 80Mm To Provide Air Cushioning To Head N• It Should Have Minimum Outer Diameter Of 150Mm Along With Vertical Thickness Of 30Mm N• It Should Have A Single Phase Continuous Surface Contoured To Complement Head Contours Protecting Skul Neck And Ears N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Mg At Vertical Angle Of Placement N• It Should Be Organic Inert Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N 108 Open Head Ring –Adult Size: N N• The Positioning Device Should Have Donut ( Hole ) At The Centre With A Minimum Inner Diameter Of 100Mm To Provide Air Cushioning To Head N• It Should Have Minimum Outer Diameter Of 200Mm Along With Vertical Thickenss Of 40Mm N• It Should Have A Single Phase Continuous Surface Contoured To Complement Head Contours, Protecting Skull Neck And Ears. N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts N• It Should Able To Hold Minimum Weight Of 200Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact N• It Should Be Organic Inert Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N 109 Closed Head Ring Neonatal Size: N• The Positioning Device Should Have A Inner Bulge At The Centre With A Minimum Inner Diameter Of 45Mm To Provide Covered Support To Soft Skull N• It Should Have Minimum Outer Diameter Of 90Mm Along With Vertical Thickness Of 20Mm N• It Should Have A Single Phase Continuous Surface Contoured To Complement Head Contours Protecting Skull Neck And Ears. N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure Shear And Frictional Impact N• It Should Be Organic, Inert Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferable Less Than Fraction Of Second N 110 Closed Head Ring – Adolescent Size: N N• The Positioning Device Should Have A Inner Bulge At The Centre With A Minimum Inner Diameter Of 70Mm To Provide Covered Support To Teen’S Head N• It Should Have Minimum Outer Diameter Of 140Mm Along With Vertical Thickness Of 35Mm N• It Should Have Single Phase Continuous Surface Contoured To Complement Head Contours, Protecting Skull Neck And Ears N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts. N• It Should Able To Hold Minimum Weight Of 200 Mg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores Pressure Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second. N 111 Closed Head Ring – Adult Size N N• The Positioning Device Should Have A Inner Bulge At The Centre With A Minimum Inner Diameter Of 100Mm To Provide Covered Support To Teen’S Head N• It Should Have Minimum Outer Diameter Of 200Mm Along With Vertical Thickness Of 45Mm N• It Should Have A Single Phase Continuous Surface Contoured To Complement Head Contours, Protecting Skull, Neck And Ears N• It Should Have Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N 112 Contoured Arm Board Pad: N• The Positioning Device Should Have Grooved Structure With Slight Curved Edge As A Supporting Surface For Extended Arm N• The Device Should Have Minimum Of Length X Width X Height 500 X 130 X35mm N• It Should Have A Single Phase Continuous Surface With Enhanced Pressure Distribution On Either Side Supporting The Anatomy Of Arm And Elbow As Ot Arm Support Device N• It Should Have A Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts N• It Should Able To Hold Minimum Weight Of 200Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N 113 Flat Arm Board Pad: N• The Positioning Device Should Have Flat Structure With No Groove Structure Having Multi Site Utility N• The Drive Should Have Minimum Of Length Of X Width X Height Of 600 X 125X 12Mm N• It Should Have A Single Phase Continuous Surface With Enhance Pressure Distribution Resting The Arm And Elbow As Ot Extensor Device N• It Should Have Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second. N 114 Contoured Knee Pad: N N• The Positioning Device Should Have Grooved Structure With Slight Curved Edge As A Supporting Surface For Resting Knee N• The Device Should Have Minimum Of Length Of X Width X Height 500 X 130X35mm N• It Should Have A Single Phase Continuous Surface With Enhanced Pressure Distribution On Either Side Supporting Contours Of Knee As Padded Support Device N• It Should Have Stick On Surface ( Without Any Chemical Adhesive ) At The Bottom Of The Positioning Device Able To Stick On The Positioning Belts N• It Should Able To Hold Minimum Weight Of 200 Kg At Vertical Angle Of Placement N• It Should Not Leak While Prick And Able To Support Complete Pressure Redistribution Preventing Bed Sores, Pressure, Shear And Frictional Impact N• It Should Be Organic, Inert, Reusable And Should Not Bottom Out With Repeated Usage N• It Should Be Made Up Of Artificial Cushioning Gel With Maximum Rebounding Capacity On Withdrawal Of Pressure, Preferably Less Than Fraction Of Second N• It Should Have A Universal Testing Kit For Testing The Quality Of Material N• It Should Comply With Standard Operating Procedures Laid By Association Of Surgical Technologists For Operation Theatre Positioning Devices, Self Certification Should Be Provided By The Manufacturer. N 115 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen Catheter 20, 23, 23G, Dilator 5 Fr., Introducer Needle 21G Kit For Injecting Or Infusing Different Solution And Medications. Centimetre Marking From 5 To 12 Cm Guide Wire Should Be Nitinol ( Kink-Resistant J Guide Wire ) . Nsize: 4-4.5 Fr. Length -6 Cm N 116 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen Catheter 20, 23, 23G, Dilator 5 Fr., Introducer Needle 21G Kit For Injecting Or Infusing Different Solution And Medications. Centimetre Marking From 5 To 12 Cm Guide Wire Should Be Nitinol ( Kink-Resistant J Guide Wire ) . Nsize: 4-4.5 Fr. Length -8 Cm N 117 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen Catheter 20, 23, 23G, Dilator 5 Fr., Introducer Needle 21G Kit For Injecting Or Infusing Different Solution And Medications. Centimetre Marking From 5 To 12 Cm Guide Wire Should Be Nitinol ( Kink-Resistant J Guide Wire ) . Nsize: 4-4.5 Fr. Length -10 Cm N 118 Neonatal Double Lumen Central Venouscatheter N3fr. Nneonatal Double Lumen Polyurethanecentral Venous Catheter Radiopaque For Injecting Or Infusing Different Solutions And / Or Medications Simultaneously. Ntray Containing: N1 Double Lumen Catheter With Centimetre Markings From 4Cm From Distal Tip, 1 Short I.V Cannula 24G – Length 19Mm, 1 Introducer Needle 22G, 1 Straight Guidewire, 2 Dilators 3-3.5Fr. ( Length 3Cm And 5Cm ) , 1 Secondary Fixation Wing, 2 Injection Caps, 1 Scalpel, 1 5Ml Syringe. Nsize: 3Fr. Length – 5-14 Cm N 119 Triple Lumen Central Venous Catheter Kit ( Adult ) N14g, 18G, 18G Nshould Be Polyurethane Triple Lumen Catheter With Flexible Distal Tip With J Guide Wire. Should Be Fully Radiopaque With Graduations At Each Centimetre From 5Cm From The Distal Tip. Should Have Colored Hubs With Distal Lumen With A Large Diameter ( 14G ) For Optimum Flow, Middle & Proximal 18X18. Nadult Size – Fr. 7.5, Length 16Cm N 120 Triple Lumen Central Venous Catheter Kit ( Adult ) N14g, 16G, 16G Nshould Be Polyurethane Triple Lumen Catheter With Flexible Distal Tip With J Guide Wire. Should Be Fully Radiopaque With Graduations At Each Centimetre From 5Cm From The Distal Tip. Should Have Colored Hubs With Distal Lumen With A Large Diameter ( 14G ) For Optimum Flow, Middle & Proximal 18X18. Nadult Size – Fr. 8 To 8.5F, Length 16Cm N 121 Femoral Arterial Cannula ( Adult ) 20 G Nfemoral Arterial Cannula ( Adult ) Polyethylene Transparent Arterial Catheter With Radiopaque Lines Introduced Using The Seldinger Technique And Equipped With A Puncture Needle Allowing Visualization Of The Arterial Pulsations Without Blood Spillage On Needle Insertion. The Puncture Needle Should Be Fitted With A Visualization Chamber Allowing To Confirm That The Vessel Punctured Is An Artery ( Pulsatile Movement Of The Blood ) . The Needle Should Be Fitted With A Silicone Bls Valve ( Bls: Bloodless System ) To Avoid Loss Of Blood During Vessel Puncture And A Funnel Hub To Facilitate The Insertion Of The Guide Wire. Nsize- 20G, Length 8Cm. N 122 Femoral Arterial Cannula ( Adult ) 18 G None Transparent Xro Catheter ( Polyethylene ) , One Introducer Needle, Should Have One Straight Guide Wire With Flexible Tip And Anti-Kink Collar. Nsize- 18G- Length 10Cm. N 123 Femoral Arterial Cannula ( Adult ) 16 G None Polyurethane Xro Catheter With 5 To 20 Cm Marking On Catheter, One Introducer Needle, J Guide Wire- Advancer.Size-16G- Length 15Cm. N 124 One Polyurethane Xro Catheter With 5 To 20 Cm Marking On Catheter, One Introducer Needle, J Guide Wire- Advancer. 16G-Length 20Cm. 125 Peads Arterial Catheter Set / Kit 20G Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-20 G- Length 4 Cm. N 126 Peads Arterial Catheter Set / Kit 20G Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-20 G- Length 6 Cm. N 127 Peads Arterial Catheter Set / Kit 20G Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-20 G- Length 8, Cm. N 128 Peads Arterial Catheter Set / Kit 20G Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-20 G- Length 20 Cm. N 129 Peads Arterial Catheter Set 22G: Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-22G- Length 4 Cm N 130 Peads Arterial Catheter Set 22G: Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-22G- Length 6, N 131 Peads Arterial Catheter Set 22G: Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guide Wire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-22G- Length 8 Cm N 132 Peads Arterial Catheter Set 22G: Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-22G- Length 12 Cm N 133 Peads Arterial Catheter Set 22G: Nfemoral Arterial Cannula ( Paed. ) Polyurethane With Radio Opaque Line Introduced By Seldinger Technique With Integral Polyurethane Extension Tube Length 4.5 Cm With Fixation Wing. Npresented In A Peel-Pack. N* 1 Polyurethane Catheter* 1 Introducer Needle N* 1 Straight Guidewire With A Flexible Tip* One 50*50 Cm Drape Sheet. Nsize-22G- Length 20 Cm N 134 Polyethylene Pressure Extension Tube Npolyethylene High Pressure Extension Tube Nsize – 11, 200Cm. N 135 Polyethylene High Pressure Extension Tube Nsize -30, 200Cm. N 136 Polyethylene High Pressure Extension Tube Nsize: –50, 200 Cm. N 137 Polyethylene High Pressure Extension Tube Nsize – 100, 200Cm. N 138 Polyethylene High Pressure Extension Tube Nsize – 150 200Cm. N 139 Anti-Biotic Impregnated Triple Lumen Catheter Nimpregnated With Rifampicin &Miconazole With Nnitinol Kink-Resistant J Guide Wire. Nadult Size: – ( A ) Fr. 7.5, Length – 16 & 20 Cm N 140 Anti-Biotic Impregnated Triple Lumen Catheter Nimpregnated With Rifampicin &Miconazole With Nitinol Kink-Resistant J Guide Wire. Npaed. Size:– ( B ) Fr. 4.5, Length – 6 & 12.5Cm. N 141 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize –16G, N 142 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize – ( B ) 18 G N 143 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize 20G N 144 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize – 22G N 145 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize 24 G N 146 Pur Iv Access Device With Port Npolyurethane Iv Access Device For Long Term Use In Icu. Nsize : 26G. N 147 Dressing: Nsterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film. N5.5X7 Cm N 148 Dressing: Nsterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film N 6.5X7cm N 149 Dressing: Nsterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film. N15x10cm N 150 Dressing: Nsterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film. N15x20cm N 151 Dressing: Nsterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film. N 30X15cm N 152 Dressing: Nsterile, Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- Allergenic Dressing Film. N 30X45 Cm N 153 Quadrilumen Central Venous Catheter N*Outer Size: 8 To 8.5 Fr. N* Port / Channel Size: 14 / 16 / 18 / 18G N* Made Of Special Grade Material . N*Length Of Catheter 15 Cm. N*18G Valve Needle With Side Port N* Semi Stiff Dilator, N* Nitinol Guide Wire, N * Safe Site Connector With An Option Of Ecg Lead For Location Confirmation N 154 Cvp Kit For Paed. N20g, 20G, 22G Npaediatric Triple Lumen Catheter. Nradiopaque Polyurethane Central Venous Catheter Inserted By Seldinger Technique1 J Type Nitinol Guide Wire For Anti-Kink. Centimetre Markings From 5Cm From The Distal Tip And Robert Clamps. Supple Distal Tip. Nthe User Can Choose From 2 Types Of Introducer, I.E. Needle Or I.V. Cannula. Npresented In A Rigid Blister Pack Containing: N1 Triple-Lumen Catheter ( 5.5Fr ) , 1 Introducer Needle 22G -Length 40 Mm, 1 Short I.V. Cannula 22G, Length 25Mm, 1 J Type Nitinol Guide Wire For Anti-Kink, 2 Dilators, 1 Secondary Fixation Wing, 3 Injection Caps, 1 Scalpel, 1 Syringe 5Ml Nsize: 5 To 5.5 Fr. Length - 8Cm N 155 Cvp Kit For Paed. N20g, 20G, 22G Npaediatric Triple Lumen Catheter. Nradiopaque Polyurethane Central Venous Catheter Inserted By Seldinger Technique1 J Type Nitinol Guide Wire For Anti-Kink. Centimetre Markings From 5Cm From The Distal Tip And Robert Clamps. Supple Distal Tip. Nthe User Can Choose From 2 Types Of Introducer, I.E. Needle Or I.V. Cannula. Npresented In A Rigid Blister Pack Containing: N1 Triple-Lumen Catheter ( 5.5Fr ) , 1 Introducer Needle 22G -Length 40 Mm, 1 Short I.V. Cannula 22G, Length 25Mm, 1 J Type Nitinol Guide Wire For Anti-Kink, 2 Dilators, 1 Secondary Fixation Wing, 3 Injection Caps, 1 Scalpel, 1 Syringe 5Ml Nsize Size: 5 To 5.5 Fr. Length -12 To 13 Cm N 156 Cvp Kit For Paed. N20g, 20G, 22G Npaediatric Triple Lumen Catheter. Nradiopaque Polyurethane Central Venous Catheter Inserted By Seldinger Technique1 J Type Nitinol Guide Wire For Anti-Kink. Centimetre Markings From 5Cm From The Distal Tip And Robert Clamps. Supple Distal Tip. Nthe User Can Choose From 2 Types Of Introducer, I.E. Needle Or I.V. Cannula. Npresented In A Rigid Blister Pack Containing: N1 Triple-Lumen Catheter ( 5.5Fr ) , 1 Introducer Needle 22G -Length 40 Mm, 1 Short I.V. Cannula 22G, Length 25Mm, 1 J Type Nitinol Guide Wire For Anti-Kink, 2 Dilators, 1 Secondary Fixation Wing, 3 Injection Caps, 1 Scalpel, 1 Syringe 5Ml N Size: 5 To 5.5 Fr. Length - 15Cm N 157 Vial Adapter: Nfor Withdrawal Of Sterile Solution From Sterile Vial To Maintain Sterility. It Should Have Fda / European Ce ( From Notified Body ) Certification. N 158 Urine Bag With Non-Return Valve: Nurine Bag With Non-Return Valve For Critical Icu Patients “Individually Packed Sterile Urine Bag With Non-Return Valve, 2000 Ml Capacity, Needle Free Kombicon Port, 3Micron Hydrophobic Filter, Integrated Hanger And Tube Clamp, Fitted With Cross Valve Bottom Outlet” N 159 Fecal Management System: Nflexiseal: Fecal Management System Should Have Highly Flexible Silicone Catheter With Balloon And Two Ports For Irrigation And Inflation ( 45Ml ) , With Finger Cuff Pocket For Easy Insertion. It Should Have Odor Barriers And Must Conform To Sphincter Anatomy, Made Of Latex-Free And Pvc- Free Components, With At Least 3 Collection Bags With Odor Control.With Signal Indicator. N 160 Silicone Siloxanes Releaser: N100% Blend Of Silicone Sting Free Hypo-Allergic Non-Alcoholic Containing Siloxanes Adhesive Releaser Spray Should Be In 50Ml Bottle. N 161 Triple Lumen Catheter ( Paediatric ) N20, 22, 22G Ntriple Lumen Catheter Should Be Polyurethane With Flexible Distal Tip Nickel-Titanium Kink Resistant With J Guide Wire. Should Be Fully Radiopaque With Graduations At Each Centimeter From 5Cm From The Distal Tip. Should Have Colored Hubs With Distal Lumen With A Large Diameter For Optimum Flow, Middle & Proximal 20X22x22. Nsize: – ( A ) 5.5 Fr. Length 6Cm N 162 Triple Lumen Catheter ( Paediatric ) N20, 22, 22G Ntriple Lumen Catheter Should Be Polyurethane With Flexible Distal Tip Nickel-Titanium Kink Resistant With J Guide Wire. Should Be Fully Radiopaque With Graduations At Each Centimetre From 5Cm From The Distal Tip. Should Have Colored Hubs With Distal Lumen With A Large Diameter For Optimum Flow, Middle & Proximal 20X22x22 Nsize: – 5.5 Fr. Length 8Cm N 163 Triple Lumen Catheter ( Paediatric ) N20, 22, 22G Ntriple Lumen Catheter Should Be Polyurethane With Flexible Distal Tip Nickel-Titanium Kink Resistant With J Guide Wire. Should Be Fully Radiopaque With Graduations At Each Centimetre From 5Cm From The Distal Tip. Should Have Colored Hubs With Distal Lumen With A Large Diameter For Optimum Flow, Middle & Proximal 20X22x22. Nsize: – 5.5 Fr. Length 13Cm N 164 Pressure Transducer Kit For Blood Sampling: Npressure Transducer Kit Ninvasive Blood Pressure Transducer With Integrated Unit For Clinical Accuracy Ndual Mode Of Flushing, Controlled Squeeze And Snap Tab Ncompletely Transparent For Ease Of Priming And Debubbling Navailable With Flushing Of 3Cc / Hr, Easy Zeroing Nclass Iv Implanted Tested Tubing Dehp Free Nneedless Systems With Ease Of Blood Sampling Nactivated By Luer Slip Syringe Nminimal Risk Of Infections And Cross Contamination Ninbuilt 6Ml Reservoir Syringe To Facilitate Ample Clearing Volume Npiston Is Protected By Silicon Sheath Nbonded Connections To Minimize The Risk Of Disconnection N Single Line Dptkit N 165 Pressure Transducer Kit Ninvasive Blood Pressure Transducer With Integrated Unit For Clinical Accuracy Ndual Mode Of Flushing, Controlled Squeeze And Snap Tab Ncompletely Transparent For Ease Of Priming And Debubbling Navailable With Flushing Of 3Cc / Hr, Easy Zeroing Nclass Iv Implanted Tested Tubing Dehp Free Nneedless Systems With Ease Of Blood Sampling Nactivated By Luer Slip Syringe Nminimal Risk Of Infections And Cross Contamination Ninbuilt 6Ml Reservoir Syringe To Facilitate Ample Clearing Volume Npiston Is Protected By Silicon Sheath Nbonded Connections To Minimize The Risk Of Disconnection Ndouble Line Dptkit N 166 Patient Warming Blanket ( Adult ) - Full Body ( 100X195cm ) Npatient Warming Blanket ( Adult ) Full Body Latex-Free Compatible With All Leading Enforced Air Patient Warming Systems. Nunique Microscopic Perforation To Provide For Even Air Distribution Without The Risk Of Residue. Nample Dimensions To Accommodate All Patients. Nuniversal Inner Port Lines To Ensure The Hose Remains Firmly In The Blanket. Ndimension: 100X195cm. N 167 Patient Warming Blanket ( Adult ) - Lower Body ( 100X120cm Npatient Warming Blanket ( Adult ) Lower Body Latex-Free Compatible With All Leading Enforced Air Patient Warming Systems. Nunique Microscopic Perforation To Provide For Even Air Distribution Without The Risk Of Residue. Nample Dimensions To Accommodate All Patients. Nuniversal Inner Port Lines To Ensure The Hose Remains Firmly In The Blanket. Generous Amount Of Tape To Secure Blanket Over Abdomen. Ndimension: 100X120cm. N 168 Patient Warming Blanket ( Adult ) Nunder Body Full Size: ( 206X87cm ) Nunder Body Latex-Free Compatible With All Leading Enforced Air Patient Warming Systems. Nunder Body, Full, Unrestricted Surgical Access To The Patient. Nunique Microscopic Perforation To Provide For Even Air Distribution Without The Risk Of Residue. Nample Dimensions To Accommodate All Patients. Nuniversal Inner Port Lines To Ensure The Hose Remains Firmly In The Blanket. Generous Amount Of Tape To Secure Blanket Over Abdomen. Ndimension: 206X87cm. N 169 Patient Warming Blanket ( Paediatric ) Full Body ( 100X120cm ) N Nfull Body Latex-Free Compatible With All Leading Enforced Air Patient Warming Systems. Nunique Microscopic Perforation To Provide For Even Air Distribution Without The Risk Of Residue. Nample Dimensions To Accommodate All Pediatrics Patients. Nuniversal Inner Port Lines To Ensure The Hose Remains Firmly In The Blanket. Generous Amount Of Tape To Secure Blanket Over Abdomen. Ndimension: 100X120cm. Should Be N 170 Disposal Syringe 1Ml Volume N• 1Ml Syringle With Needle N• Marking To Measure Exact Volume N• Smooth Needle For Sueutaneous Infiltration Nsterile Packed N 171 Ovassapianfiberoptic Intubating Airway N• Designed For Use With A Fiberoptic Bronchoscope N• Latex Free N• Allows For Removal Without Disconnecting Endotracheal Tube. N• Flat Lingual Surface N• Fits Tube Size 8 To 0Mm Id 172 • Should Be Able To Work On Sonoclot ( Model Scp2 ) N• Should Cotain Glass Beads ( Silica ) N• Should Have Capacity For 0.36Ml Of Blood Sample N• Should Be Able To Use With Native Whole Blood Or Citrated Whole Blood Nhypercoagulable / Hypocoagulable Screening Nplatelet Function Assessment Nhyperfibrinolysis Screening N• Should Provide Quantitative Results For Act, Clot Rate & Platelet Function Results N• Should Also Provide Qualitative & Quantitative Information On Sonoclot Signature Including Nfibrin Formation Nplatelet Funciton Nhyperfibrinolysis N 173 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N N• Pvc Tube, Latex Free N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Sizes: 3.0, Mm 174 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N• Pvc Tube, Latex Free N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Sizes:3.5Mm N 175 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N N N• Pvc Tube, Latex Free N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Sizes:4.0Mm N 176 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N N N• Pvc Tube, Latex Fre N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Sizes :4.5Mm 177 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N N• Pvc Tube, Latex Free N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Size:5.0Mm N 178 Microcuff Endotracheal Tube For Oral / Nasal Use In Paediatrics N• Pvc Tube, Latex Free N• Conforming To F-29 Standards N• Thermo-Sesitive Tube Confirming To The Tract Anatomy N• Kink-Resistant N• Strong Tube Walls To Ensure Proper Ventilation N• Distal Small Atraumaticfuff ( High Volume, Low Pressure Type ) N• Soft Cuff With Air-Tight Seal Between Ett And Trachea N• Radio-Opaque Line Along Entire Length N• Standard 15Mm Connector N• Sterile Individually Packed In Peelable Blister Pack N• Sizes: 5.5Mm N 179 Seldinger Based Chest Tube Set: N• Seldinger Placement Technique Chest Straight Tube With Echogenic Needle, N• Radiopaque Catheter Markings, N• Serial Dilators Having Radiopaque Centimeter Markings, N• Various Sizes 8 Fr To 36 Fr, N• Needle Holder Cap In Set N 180 Disposable Infant T-Piece Resuscitator Nshould Be Flow Controlled To Deliver Positive Pressure Ventilation To The Infants. N- Should Have Inbuilt Colour Coded Manometer And Pressure Relief Valve. N- Should Have Ability To Measure A More Consistent, Targeted In Line Peak Inspiratory Pressure ( Pip ) Controller With Override Button And Positive End-Expiratory Pressure Peep N- Should Have Variabletactile Peep Knob To Increase Or Decrease The Pressure. N- Should Be Able To Use With Clear Anatomical Or Round Silicon Face Mask N 181 Offsert Connector Electrode N• It Should Have High Conductive Wet Gel To Ensure Reliable Traces. N• It Should Have Superior Adhesion To Prevent False Alarms N• It Should Be Design With Offset Connector To Prevent Artifacts From Disrupting The Readouts N• It Should Have High Quality Ag / Agcl Sensor To Ensure Excellent Trace Quality N• It Should Have Combination Of Instant And Long Term Adhesive Which Secures Optimal Fixation And Precise Recordings N• It Should Have Breathable Microporous And Hypoallergenic Material Which Ensures Optimal Skin Care N• It Should Have Size Not More Than 72 X 68 Mm N• Sizes –Adult N 182 Offsert Connector Electrode N• It Should Have High Conductive Wet Gel To Ensure Reliable Traces. N• It Should Have Superior Adhesion To Prevent False Alarms N• It Should Be Design With Offset Connector To Prevent Artifacts From Disrupting The Readouts N• It Should Have High Quality Ag / Agcl Sensor To Ensure Excellent Trace Quality N• It Should Have Combination Of Instant And Long Term Adhesive Which Secures Optimal Fixation And Precise Recordings N• It Should Have Breathable Microporous And Hypoallergenic Material Which Ensures Optimal Skin Care N• It Should Have Size Not More Than 72 X 68 Mm N• Sizes ( B ) Paed. N 183 Offsert Connector Electrode N• It Should Have High Conductive Wet Gel To Ensure Reliable Traces. N• It Should Have Superior Adhesion To Prevent False Alarms N• It Should Be Design With Offset Connector To Prevent Artifacts From Disrupting The Readouts N• It Should Have High Quality Ag / Agcl Sensor To Ensure Excellent Trace Quality N• It Should Have Combination Of Instant And Long Term Adhesive Which Secures Optimal Fixation And Precise Recordings N• It Should Have Breathable Microporous And Hypoallergenic Material Which Ensures Optimal Skin Care N• It Should Have Size Not More Than 72 X 68 Mm N• Sizes –Neonatal N 184 Nirs Sensor Nshould Be Compatible With Medtronic Nirs Monitor. N-Sizes - Adult, N 185 Nirs Sensor Nshould Be Compatible With Medtronic Nirs Monitor. N-Sizes – Pediatric N 186 Nirs Sensor Nshould Be Compatible With Medtronic Nirs Monitor Nsizes - Neonatal N 187 Nirs Sensor Nshould Be Compatible With Nonin Nirs Monitor. Nsizes - Adult, N 188 Nirs Sensor Nshould Be Compatible With Nonin Nirs Monitor. Nsizes - Pediatric N 189 Nirs Sensor Nshould Be Compatible With Nonin Nirs Monitor. N-Sizes - Neonatal N 190 Bis Sensor Nit Should Have Four Sensors Element To Capture, Recognize And Discard Artifact. Nconnector Should Provide Secure Click-In Connection With Push Button Release Nit Should Include An Additional Above Eye Element, Which Captures Critical Eye Motion Data, Along With Other Important Physiological Signals. Nit Should Have Flexible Design Adjusts To Different Head Sizes Nshould Be Supplied By Authorized Channel Partner From Principal Company / Manufacture. Nelectrode Gel: Potassium Chloride ( Kcl ) , Latex Free. Nsizes: Adult N 191 Bis Sensor: Nit Should Have Four Sensors Element To Capture, Recognize And Discard Artifact. Nconnector Should Provide Secure Click-In Connection With Push Button Release Nit Should Include An Additional Above Eye Element, Which Captures Critical Eye Motion Data, Along With Other Important Physiological Signals. Nit Should Have Flexible Design Adjusts To Different Head Sizes Nshould Be Supplied By Authorized Channel Partner From Principal Company / Manufacture. Nelectrode Gel: Potassium Chloride ( Kcl ) , Latex Free. N• Sizes: Pediatric N 192 Nellcor Spo2 Disposable Sensor Nspecifications: N• Should Give Accurate Readings, Even During Low Perfusion And Most Types Of Signal Interference, Including Patient Motion. N• Should Oversee A Wide Range Of Patients, From Neonates To Adults, Including Those Who Require Long-Term Monitoring. N• Should Improve The Clinical Relevance Of The More Challenging Alarms And Easily Distinguish Between Minor Transient Events And Clinically Significant Desaturations. N• Should Have Lo Sat Expanded Accuracy Feature To Accurately Track Spo2 In Low-Saturation Conditions. N• Should Perform Quick Spot-Checks Or Continuously Monitor Patients In Any Location. N• Should Have Confidence In The Accuracy With Oximax™ Technology And The Extensive Portfolio Of Nellcor™ Sensors. N• Should Have Faraday Shield To Protect From Ambient Light. N• Should Have Disposable Sensors For Adult, Pediatric, Neonates& Infants. N• Should Have Digital Calibration. N 193 Sensor For Arterial Pressure Based Cardiac Out Put Monitoring ( Flotrac ) Ndisposable Arterial Pressure Cardiac Output Sensor To Provide Co, Ci, Sv, Svi, Svv, Svr & Svri On Continuous Basis When Connected With Patient Arterial Pressure Line. Nshould Be Individually Packed. Nsterile & Ready For Use Nshouls Be Compatible With Vigileo Monitor N 194 Anti Bacterial Treated Surgical Tape: Nshould Be Made Up Of Thin Non-Woven Fabric. N- The Fabric Should Be Impregnated With Antimicrobial Compound To Suppress The Chances Of Growth Of Microbes. N- Should Meet B.P. Standard. Nsizes- 1” X 10.00 Mtrs N 195 Anti Bacterial Treated Surgical Tape: Nshould Be Made Up Of Thin Non-Woven Fabric. N- The Fabric Should Be Impregnated With Antimicrobial Compound To Suppress The Chances Of Growth Of Microbes. N- Should Meet B.P. Standard. Nsizes: 2” X 10.00 Mtrs N 196 Anti Bacterial Treated Surgical Tape: Nshould Be Made Up Of Thin Non-Woven Fabric. N- The Fabric Should Be Impregnated With Antimicrobial Compound To Suppress The Chances Of Growth Of Microbes. N- Should Meet B.P. Standard. Nsizes: 3” X 10.00 Mtrs N 197 Anti Bacterial Treated Surgical Tape: Nshould Be Made Up Of Thin Non-Woven Fabric. N- The Fabric Should Be Impregnated With Antimicrobial Compound To Suppress The Chances Of Growth Of Microbes. N- Should Meet B.P. Standard. Nsizes: 4” X 10.00 Mtrs N 198 Oxygen Recovery Kit Nit Should Be Specially Designed Kit With ‘T’ Shaped Connector For Delivering Oxygen. . Nit Should Have 15 Mm Connector To Fit All Tracheal Tubes. Nit Should Have Suction Port At Elbow To Facilitate Oro-Bronchial Suctioning Without Disconnecting The Patient From Oxygen Source. Nit Should Have Two Meter Long Star Lumen Tube To Enable To Connect The T Connector With Oxygen Source. Ndistal End Should Be Open For Exhaling The Waste Gases. N 199 Colorimetric Disposable Co2 Detector Nfor Patients From 250Gm To 15+Kg. Body Weight. N• Should Have The Facility Of Activation By Pull Tab Technique. N• Should Be Able To Work For 24 Hours Once Activated By Pulling Tab. N• Should Be Able To Indicate- Blue Green & Yellow Colour. N• Should Have Larger Co2 Viewing Window. N• Should Have 15Mm I.D. Standard Taper At Patient End & 15Mm O.D. Standard Taper At Ncircuit End. N• Sizes: Infant N 200 For Patients From 250Gm To 15+Kg. Body Weight. N• Should Have The Facility Of Activation By Pull Tab Technique. N• Should Be Able To Work For 24 Hours Once Activated By Pulling Tab. N• Should Be Able To Indicate- Blue Green & Yellow Colour. N• Should Have Larger Co2 Viewing Window. N• Should Have 15Mm I.D. Standard Taper At Patient End & 15Mm O.D. Standard Taper At Ncircuit End. N• Sizes:, ( B ) Paediatric N 201 For Patients From 250Gm To 15+Kg. Body Weight. N• Should Have The Facility Of Activation By Pull Tab Technique. N• Should Be Able To Work For 24 Hours Once Activated By Pulling Tab. N• Should Be Able To Indicate- Blue Green & Yellow Colour. N• Should Have Larger Co2 Viewing Window. N• Should Have 15Mm I.D. Standard Taper At Patient End & 15Mm O.D. Standard Taper At Ncircuit End. N Sizes: Adult N 202 Hand Restraint Nshould Be Made Up Of Soft Cotton Cloth Absorbent Material. N• Should Absorb Any Sweating By The Patient , Leaving Them Dry & Comfortable. N• By Securing The Limbs Of The Patients Through These Restraints, It Shouldgently Prevent The Npatient From Disturbing Iv Lines And The Endo- Tracheal Tubes And Other Cannulated Fluid Ndministration / Sampling Device. N 203 Ankle Restraint Nshould Bemade Up Of Soft Cotton Cloth Absorbent Material. N• Should Be Able To Absorb Any Severe Sweating By The Patients So As To Leave Them Dry And Ncomfortable. N• Should Be Able To Secure The Limbs Of The Patients Through These Restraints To Gently Prevent Nthe Patient From Disturbing Iv Lines And The Endo- Tracheal Tubes And Other Cannulated Fluid Nadministration / Sampling Device N• Should Bemade Up Of Soft Cotton Cloth Absorbent Material. N• Should Be Able To Absorb Any Severe Sweating By The Patients So As To Leave Them Dry And Ncomfortable. N 204 Washable Polymer Material Silicon Gel Tape Nshould Be Made Up Of Washable & Breathable Polymer Fabric. N-Should Have Bi-Directional Tear-Ability. N-Should Be Hand Tearable Only &Do Not Require The Use Of Scissor Or Other Instrument For Cutting. N-Should Be Breathable. N- Should Have Silicon Gel Coating For Good Adhesion. N- Atraumatic Fixation & Ideal For Skins Where Adhesive &Non Woven Tapes Are Not Recommended. N- Should Be Ideal For Soft, Sensitive & Compromised Skin. N- Each Roll Should Be Individually Packed. N- Size: 1” X 1 Mtrs. N 205 Washable Polymer Material Silicon Gel Tape N Nshould Be Made Up Of Washable & Breathable Polymer Fabric. N-Should Have Bi-Directional Tear-Ability. N-Should Be Hand Tearable Only &Do Not Require The Use Of Scissor Or Other Instrument For Cutting. N-Should Be Breathable. N- Should Have Silicon Gel Coating For Good Adhesion. N- Atraumatic Fixation & Ideal For Skins Where Adhesive &Non Woven Tapes Are Not Recommended. N- Should Be Ideal For Soft, Sensitive & Compromised Skin. N- Each Roll Should Be Individually Packed. N- Size:2” X 1 Mtrs. N N 206 Washable Polymer Material Silicon Gel Tape Nshould Be Made Up Of Washable & Breathable Polymer Fabric. N-Should Have Bi-Directional Tear-Ability. N-Should Be Hand Tearable Only &Do Not Require The Use Of Scissor Or Other Instrument For Cutting. N-Should Be Breathable. N- Should Have Silicon Gel Coating For Good Adhesion. N- Atraumatic Fixation & Ideal For Skins Where Adhesive &Non Woven Tapes Are Not Recommended. N- Should Be Ideal For Soft, Sensitive & Compromised Skin. N- Each Roll Should Be Individually Packed. N- Size: 3” X 1Mtrs. N 207 I.V. Midline Catheter Nshould Be Made Up Of Special Polyutrethane Material. N-Should Have Soft &Atrauamatic Insertion. N-Should Be A Safety Device To Prevent The Chances Of Needle Stick Injuries. N-Should Have The Injection Port With Colour Coded Cap For Drug Delivery. N-The Dwelling Period Of Catheter In Patient Should Be Around 29 Days. N-Should Have Notched Needle For Quick Blood View. N-Should Be Easy To Use. N-Should Have European Ce. N-Sizes : 16 G N 208 I.V. Midline Catheter Nshould Be Made Up Of Special Polyutrethane Material. N-Should Have Soft &Atrauamatic Insertion. N-Should Be A Safety Device To Prevent The Chances Of Needle Stick Injuries. N-Should Have The Injection Port With Colour Coded Cap For Drug Delivery. N-The Dwelling Period Of Catheter In Patient Should Be Around 29 Days. N-Should Have Notched Needle For Quick Blood View. N-Should Be Easy To Use. N-Should Have European Ce. N-Sizes : 18G. N 209 I.V. Midline Catheter: Nshould Be Made Up Of Special Polyutrethane Material. N-Should Have Soft &Atrauamatic Insertion. N-Should Be A Safety Device To Prevent The Chances Of Needle Stick Injuries. N-Should Have The Injection Port With Colour Coded Cap For Drug Delivery. N-The Dwelling Period Of Catheter In Patient Should Be Around 29 Days. N-Should Have Notched Needle For Quick Blood View. N-Should Be Easy To Use. N-Should Have European Ce. N-Sizes 20 G. N 210 I.V. Midline Catheter Nshould Be Made Up Of Special Polyutrethane Material. N-Should Have Soft &Atrauamatic Insertion. N-Should Be A Safety Device To Prevent The Chances Of Needle Stick Injuries. N-Should Have The Injection Port With Colour Coded Cap For Drug Delivery. N-The Dwelling Period Of Catheter In Patient Should Be Around 29 Days. N-Should Have Notched Needle For Quick Blood View. N-Should Be Easy To Use. N-Should Have European Ce. N-Sizes 22 G. N 211 Airway Exchange Catheter Nairway Exchange Catheter Should Have Adaptors To Connect With Manual Resuscitator Bag And Ventilator. N-Should Have Two Holes On Distal End For Ventilation. N- Should Have Cm. Markings On The Catheter. Nsizes:– 8 Fr. And 45 Cm. N 212 Airway Exchange Catheter Nairway Exchange Catheter Should Have Adaptors To Connect With Manual Resuscitator Bag And Ventilator. N-Should Have Two Holes On Distal End For Ventilation. N- Should Have Cm. Markings On The Catheter. N- -Sizes: 11Fr. 14Cm 213 Airway Exchange Catheter Should Have Adaptors To Connect With Manual Resuscitator Bag And Ventilator. N-Should Have Two Holes On Distal End For Ventilation. N- Should Have Cm. Markings On The Catheter. N- -Sizes 19Fr. 83Cm. N 214 Ventilating Bougie With Stylet N Intubating Catheter Should Have Adaptors To Connect With Manual Resuscitator Bag And Ventilator. - - Should Have Stainless Steel Stylet. N- Should Have Two Holes On Distal End For Ventilation. N-Sizes: ( A ) 14Fr. & 70Cm, N- Should Have Cm. Markings On The Catheter. N 215 Ventilating Bougie With Stylet Nintubating Catheter Should Have Adaptors To Connect With Manual Resuscitator Bag And Ventilator. - - Should Have Stainless Steel Stylet. N- Should Have Two Holes On Distal End For Ventilation. N-Sizes: 8Fr. And 35Cm. N- Should Have Cm. Markings On The Catheter. N 216 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula.14 G N 217 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula. 16G N 218 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula 18 G N 219 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula. 20G N 220 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula. 22G N 221 Back Flow Iv Cannula: Nit Should Be Made Up Of Polytetrafluoroethylene ( Ptfe ) Insta Flash Needle Technology For Faster Visualization Or Flashback By Notch, Cannula Contains Aluer_Lock Plug Attached To The Flow Control Plug, Is A Disposable Device. Has An Injection Port And Flexible Wings To Support The Cannula- 24 G N 222 Eylid Occlusion Dressings N• Size: Paediatric N• Material-100% Polyurethane Clear Film Layer N• Polyster Non –Woven Fabric N• Solvent Base Acrylic Adhesive N• Sterilized With Ethylene Oxide N• 1005 Latex Free Dual Zone With Central Window Transparent N• Packed In Medical Grade Paper And Laminate Pouch N• Skin Friendly N 223 Eylid Occlusion Dressings N• Size: Adult N• Adult Size-3.7Cm X 9.3Cm N• Material-100% Polyurethane Clear Film Layer N• Polyster Non –Woven Fabric N• Solvent Base Acrylic Adhesive N• Sterilized With Ethylene Oxide N• 1005 Latex Free Dual Zone With Central Window Transparent N• Packed In Medical Grade Paper And Laminate Pouch N• Skin Friendly N 224 Endotracheal Tube Plain N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: ( A ) 2.5 N 225 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 3.0, N 226 Endotracheal Tube Plain: N N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 3.5 N 227 Endotracheal Tube Plain N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 4.0 N 228 Endotracheal Tube Plain: N N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 4.5 N 229 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peel Able Blister Pack. N Sizes: 5.0 N 230 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 5.5 N 231 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 6.0 N 232 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 6.5, N 233 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes:7.0 N 234 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsize:7.5 N 235 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 8.0 Cm 236 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N 8.5 Cm N 237 Endotracheal Tube Plain: N• Manufactured From Thermo-Sensitive Material Which Conforms To Body Contours At Body Temperature. Pvc N• Kink Resistant And Transparent Material To Prevent Occlusion In The Tube Bore. N• Nasoral Tip Suitable For Nasal / Oral Intubation. N• Murphy Eye With Smooth Edges And Tip To Reduce Any Trauma. N• Radio-Opaque Line Throughout The Length Of The Tube For X-Ray Detection And Assistance In Placement. N• Should Have 1Cm Marking From Tip To Base For Proper Fixation. N• Proximal End Is Fitted With Standard 15 Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N 9.0 N 238 Endotracheal Tube Cuffed: N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 2.5 N 239 Endotracheal Tube Cuffed: N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 3 N 240 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 3.5 N 241 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 4 N 242 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 4.5 N 243 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 5 N 244 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 5.5 N 245 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 6 N 246 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 6.5 N N 247 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 7 N 248 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 7.5 N 249 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. N Sizes: 8 N 250 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 8.5 N 251 Endotracheal Tube Cuffed N• Thermo-Sensitive Tube Conforms To The Tract Anatomy. Pvc Tube Latex Face N• Conforms To F-29 Standards. N• Kink Resistant Tube For Patient Safety. N• Strong Tube Walls To Ensure Proper Ventilation. N• Murphy Eye With Polished Smoothness For Atraumatic Intubation And Extubation. N• High-Volume, Low Pressure Cuff. N• Soft Cuff Air Tight Fit Between The Tube And Trachea. N• Should Have 1Cm Markings From Tip To Base For Proper Fixation N• Wide Black Ring Above Cuff For Visual Indication Of Tube Passing The Vocal Cords To Aid In Placement. N• Radio-Opaque Line For Exact Location. N• Standard 15Mm Connector. N• Sterile Individually Packed In Peelable Blister Pack. Nsizes: 9 N 252 Eyelid Occlusion Dressing N• Size: 3.7Cmx 9.3Cm N• Material-100% Polyurethane Clear Film Layer N• Polyster Non –Woven Fabric N• Solvent Based Acrylic Adhesive N• Styerilized With Ethylene Oxide N• 1005 Latex Free Dual Zone With Central Window Tranparent N• Packed In Medical Grade Paper And Laminate Pouch N• Skin Friendly N• Size: ( A ) Paediatric N• Size Adult:-3.7Cmx9.3Cm N 253 Eyelid Occlusion Dressing N• Size: 3.7Cmx 9.3Cm N• Material-100% Polyurethane Clear Film Layer N• Polyster Non –Woven Fabric N• Solvent Based Acrylic Adhesive N• Styerilized With Ethylene Oxide N• 1005 Latex Free Dual Zone With Central Window Tranparent N• Packed In Medical Grade Paper And Laminate Pouch N• Skin Friendly N• Size: Adult N• Size Adult:-3.7Cmx9.3Cm N 254 Eye Pressure Shield: N• Should Be Made Of Soft Foam And Rigid Plastic Shield . N• Should Have Foam Type No Less Than Wa-18 H Grade. N• Foam Thickness Should Be 17 To 19 Mm N• Shield Should Have Plastic Type , No Less Than , Triton Tx 2001 With 3M Adhesive Type N• Should Have Transparent Plastic Central Or Eye Piece . N• The Size Of Eye Pressure Shield Should Be 400Mm N• The Eye Pressure Shield Have Weight Not More Than 50 Gm. N• The Eye Pressure Shield N• The Material Should Be Skin Friendly N• Size: Paediatric N• Should Have A Strap To Secure Its Position N 255 Eye Pressure Shield: N• Should Be Made Of Soft Foam And Rigid Plastic Shield . N• Should Have Foam Type No Less Than Wa-18 H Grade. N• Foam Thickness Should Be 17 To 19 Mm N• Shield Should Have Plastic Type , No Less Than , Triton Tx 2001 With 3M Adhesive Type N• Should Have Transparent Plastic Central Or Eye Piece . N• The Size Of Eye Pressure Shield Should Be 400Mm N• The Eye Pressure Shield Have Weight Not More Than 50 Gm. N• The Eye Pressure Shield N• The Material Should Be Skin Friendly N• Size: Adult. N• Should Have A Strap To Secure Its Position. N 256 Triple Lumencentral Venous Catheter Kit ( 16G, 18G, 18G ) Size: 7 Fr. N• The Triple Lumen Catheter Should Be Of Biocompatible Polyurethanewith Flexible Distal Tip N• Should Have Flexible Kink Resistance J-Tip Guide Wire N• Should Be Fully Radioopaque With Graduation At Each Cm N• Should Have Colour Coded Lock Fittings. N• Should Have Fixation Wing At The Channel Junction For Securing The Catheter N• Should Have Distal Lumen Of Larger Diameter ( 16G ) &Middle And Proximal Lumen Of Smaller Diameter ( 18G ) Each ) . N• Should Have Length Of 8Cm / 13Cm / 16Cm. N• Kit Should Contain Ncentral Venous Catheter With Clamp And Injection Caps. Nguide Wire Ndilator Nintroducer Needle N5 Ml Syringe. Nfastener. N• Tray N 257 Triple Lumen Central Venous Catheter Kit N ( 18G, 20G, 20G ) Size: 6.5 Fr. To 7.5 Fr. N• The Triple Lumen Catheter Should Be Of Biocompatible Polyurethane With Flexible Distal Tip N• Should Have Flexible Kink Resistance J-Tip Guide Wire , N• Should Be Fully Radioopaque With Graduation At Each Cm N• Should Have Colour Coded Lock Fittings. N• Should Have Fixation Wing At The Channel Junction For Securing The Catheter N• Should Have Distal Lumen Of Larger Diameter ( 18G ) &Middle And Proximal Lumen Of Smaller Diameter ( 20G ) Each ) . N• Should Have Length Of 8Cm / 13Cm / 16Cm. N• Kit Should Contain Ncentral Venous Catheter With Clamp And Injection Caps. Nguide Wire Ndilator Nintroducer Needle N5 Ml Syringe. Nfastener. Ntray N 258 Anti Uv Pm Line Nfor Light Sensitive Drugs N1.Should Be Spirally Coiled Tubing. N2.Made Of Dehp For Polyethylene Material N3.Opaque Tubing To Prevent Light Exposure For Light Sensitive Drugs . N4.Size: 200 Cm N5.Lure Lock-One End Male And Other End Female , N 6.The Terminal Should Also Be Opaque N 259 Anti Uv Pm Line N1.Should Be Spirally Coiled Tubing. N2.Made Of Dehp For Polyethylene Material N3.Opaque Tubing To Prevent Light Exposure For Light Sensitive Drugs . N4.Size: 150Cm N5.Lure Lock-One End Male And Other End Female , N 6.The Terminal Should Also Be Opaque N

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Mar-2020 Corrigendum for date extension Date 14-04-2020
2 03-Apr-2020 Further extension of critical dates Date 27-04-2020

Key Value

Document Fees
Refer document
EMD
INR 100000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Purchase of Disposable items for cardiac anaesthesiology Deptt. On two years rate contract basis.
Sl. No. Item Description Item Code / Make Quantity Units
1 1.001 Purchase of Disposable items for cardiac anaesthesiology Deptt. On two years rate contract basis.
2 1.01 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size:5.0 mm item1 40 pices
3 1.02 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size:5.5 mm item2 40 pices
4 1.03 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size: 6.0 mm item3 40 pices
5 1.04 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size:6.5 mm item4 40 pices
6 1.05 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size:7.0 mm item5 40 pices
7 1.06 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size: 7.5 mm item6 40 pices
8 1.07 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size: 8.0 mm\n item7 40 pices
9 1.08 Tracheostomy tube (Cuffed)-\n• Tracheostomy tube Cuffed with introducer\n• Provided with holed inner cannula for easy insertion of guide wire\n• Tapered tip for easy passage\n• Low pressure cuff\n• Size of the tube mentioned on the flange\n• Adjustable Hange\n• Tape for fixation\n• Size:8.5 mm item8 40 pices
10 1.09 Latex Free ECG Electrodes:\n• White foam type, centred snap with specially formulated solid Ag/AgCl gel.\n• Hypo allergic adhesive, Latex free, Non Irritant. item9 52000 pices
11 1.1 Multiport Airway Adaptor:\n• Silicone capped connectors for bronchoscopy\n• Silicon diaphragm to allow insertion of bronchoscope or suction catheter\n• Connection to Endotradeal tube and ventilator item10 200 pices
12 1.11 Mount Catheter Flip Tap \nCollapsible corrugated tube manufactured of Polyethylene material\nDouble flip tap cap with diameter of silicone port = 3.4 mm and of Suction port = 9.4 mm\n22 mm female connector is compatible with all breathing &ventilator circuits\nInert to all anaesthetic gases & reagents item11 400 pices
13 1.12 Hourly Urine measurement bag – Size: 500 ml\n\n• Hourly urine measurement collection bag consists of 500 ml clear & transparent measured volume chamber divided in four partitions of 50ml, 200ml, 350ml & 500 ml. \n• Each partition can be drained both individually and collectively\n• 2 Ltr urine collection bag with bottom drain outlet \n• 150 cm long kink resistant tubing with corrugated protector.\n• Mid stream closed urine culture sample port must be provided in tapered connector making it a completely close circuit eliminating risk of infection. \n• 2 Rubber straps provided for bed side hanging. item12 2000 pices
14 1.13 Hourly Urine measurement bag: – Size: 250 ml\n\n• Graduated transparent measured volume chamber 250 ml. \n• Fully closed circuit drainage\n• 2 Ltr Urine collection bag with bottom drain outlet \n• 150 cm long kink resistant tubing.\n• Foldable hanger with tube holder\n• Sterile, individually packed. \n item13 6000 pices
15 1.14 Hourly Urine measurement bag – Size: 100 ml\n• Graduated transparent measured volume chamber 100 ml. \n• Fully closed circuit drainage\n• 2 Ltr Urine collection bag with bottom drain outlet \n• 150 cm long kink resistant tubing.\n• Foldable hanger with tube holder\n• Sterile, individually packed. \n item14 2000 pices
16 1.15 Disposable patient wipes:\n• Size: 300 mm x 240 mm SpunlaceNon wovenFabric Sheet.\n• Soaked in a solution consists of ChlorohexidineGluconate, Propylene Glycol, DimethiconeCopolyol, and other ingredients along with Aloe Vera, Glycerin, Hydrogenated castor oil, Fragrance and Citric Acid/ Tea.\n• Alcohol Free\n• Pack Size: of 10 pcs.\n item15 1000 pices
17 1.16 Nanofiber Mask:\nHigh Efficiency Nanofiber Filter mask, retains particulate matter above 0.3 micron\n• Ergonomically designed for a comfortable fit and ensures complete fitment on the face to prevent any leakage.\n• Anti-smoke, anti-dust, anti-pollen, anti-fog, anti-haze.\n• Prevent allergens associated with pollens, dust, mites, etc.\n• High filtration efficiency combined with low resistance \n• Individually packed in a lock pouch pack with tear open slot.\n item16 120000 pices
18 1.17 Corrugated Oxygen connector:\n• A specially designed kit with T for oxygen delivery \n• 15 mm connector \n• Suction port at the elbow \n• 2 meter star lumen oxygen tube \n• Open distal end \n• Sterile, individually packed item17 400 pices
19 1.18 Eye shield Fog Free Mask with Visor:\n• It should be consisted fog-free multilayer with visor\n• It should be made of pleat-style with ties.\n• It should have high fluid resistance capability.\n• It should have particulate filtration efficiency more than 99%\n• It should have bacterial filtration efficiency more than 99%.\n item18 1000 pices
20 1.19 Endobronchial Tube- Double Lumen\n• Robert shaw tube, double lumen with two cuffs\n• Anatomically correct curvatures\n• High Volumes, low pressure tracheal cuff\n• Colour coded pilot balloons with luer lock connector, marked with the name of the lumen \n• D shaped lumina\n• Double swivel connections with double caps\n• Suitable for one lung ventilation\n• Right sided ET Tube\nSizes :- 28FG\n item19 60 pices
21 1.2 Endobronchial Tube- Double Lumen\n• Robert shaw tube, double lumen with two cuffs\n• Anatomically correct curvatures\n• High Volumes, low pressure tracheal cuff\n• Colour coded pilot balloons with luer lock connector, marked with the name of the lumen \n• D shaped lumina\n• Double swivel connections with double caps\n• Suitable for one lung ventilation\n• Right sided ET Tube\nSizes :- 32FG\n item20 60 pices
22 1.21 Collapsible Breathing System with 2 Ltr bag:\n• Corrugated, flexible and lightweight tubing\n• Standard Connectors\n• Sterile, latex free\n• 2 Ltr. Bag, 22mm tube, 2 mtr. & 1.5 mtr Limb.\n item21 4000 pices
23 1.22 Collapsible Breathing System with 3 Ltr. bag\n• Corrugated, flexible and lightweight tubing\n• Standard Connectors\n• Sterile, latex free\n• 3 Ltr Bag, 22mm tube, 2 mtr& 1.5 mtr Limb\n item22 1000 pices
24 1.23 EZ Blocker:\n• 2 distinct proximal balloons for inflation\n• 7Fr. Bifurcated Distal end (Y shaped)\n• High volume low pressure cuff\n• Adaptor with scope lid\n• Oxygen adaptor\n• Depth markers\n• Central \n item23 100 pices
25 1.24 Collapsible Breathing System 2 mtr. with elbow\n• Corrugated, flexible and lightweight tubing\n• Standard Connectors\n• Sterile, latex free 22mm tube, 2 mtr, with luerelbo\n item24 1000 pices
26 1.25 Collapsible Breathing System 3 mtr with elbow:\n• Corrugated, flexible and lightweight tubing\n• Standard Connectors\n• Sterile, latex free \n• 22mm tube, 3 mtr, with luer elbow\n item25 1000 pices
27 1.26 IV Set with flow Controller with luer lock (DEHP Free)\n• Manufactured from DEHP free medical grade material, free from phthalates.\n• Sharp vented spike set with 1.2 micron air vent\n• DEHP free drip chamber with 1.5 micron disc filter.\n• Latex free resealing type ‘Y’injection port for extra medication\n• Advance rotating Luer Lock at distal end\n• Should have prime stopper/ air stopper membrane. item26 2000 pices
28 1.27 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\n• Size : 0\n item27 40 pices
29 1.28 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\nSize : 1, \n item28 40 pices
30 1.29 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\n• Size : 2 \n item29 40 pices
31 1.3 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\n• Size : 3\n item30 40 pices
32 1.31 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\n• Size : 4\n item31 40 pices
33 1.32 Silicone mask for resuscitator\n• Spare Silicone Mask for Resuscitator \n• Autoclavable\n• Size : 5\n item32 40 pices
34 1.33 IV Extension with flow controller:\n• I V extension line with precision rotating type controller\n• Y –site and Male/Female Luer lock.\n item33 2000 pices
35 1.34 PVC free O2 Mask\n• (A)Size : Adult\n• Soft seal, double moulded, PVC free O2 mask\n• No unpleasant odour\n• Cushion provides better O2 concentration\n• Leaves little air blind angle \n• No metal nose clip making it MRI compatible item34 200 pices
36 1.35 PVC free O2 Mask\n Size: Child\n• Soft seal, double moulded, PVC free O2 mask\n• No unpleasant odour\n• Cushion provides better O2 concentration\n• Leaves little air blind angle \n• No metal nose clip making it MRI compatible item35 200 pices
37 1.36 PVC free Aerosol Mask\nSize : Adult \n• Soft seal, double moulded, PVC free aerosol mask\n• Medical grade PP material\n• No unpleasant odour\n• Cushion provides better seal, reducing medicine wastage\n• Leaves little air blind angle \n• No metal nose clip making it MRI compatible item36 200 pices
38 1.37 PVC free Aerosol Mask:\n• Size: Child\n• Soft seal, double moulded, PVC free aerosol mask\n• Medical grade PP material\n• No unpleasant odour\n• Cushion provides better seal, reducing medicine wastage\n• Leaves little air blind angle \n• No metal nose clip making it MRI compatible item37 200 pices
39 1.38 Multigang manifold\n\n• Polycarbonate body\n• Ergonomic, low torque acetyl handle\n• Easy grip, smooth rotation item38 320 pices
40 1.39 Mapelson D System\n\n• A co-axial modification of the “T”-piece system\n• Convenient, lightweight anesthesia delivery system.\n• Based on Mapleson “D” system, provided with a corrugated tube, expiratory valve and antistatic bag 2 Ltr.\n• 22 mm cap, 22mm corrugated tube, 1.6mtr, 22 mm expiratory valve\n• Standard connectors, with low dead-space.\n• Sterile and individually packed. item39 200 pices
41 1.4 Mapelson F System:\n• Convenient, lightweight anesthesia delivery system.\n• Based on Mapleson “F” system, provided with 15mm and 10mm corrugated tube, expiratory valve and antistatic bag 0.5 Ltr, rebreathing bag and bag bleed valve.\n• 22 mm cap, 15mm corrugated tube, 0.42mtr and 10mm corrugated tube, 2mtr, expiratory valve\n• Standard connectors, extra circuit adapters\n• Sterile and individually packed\n item40 200 pices
42 1.41 Hi FiO2 mask\n• Specially designed for high concentration oxygen therapy.\n• Soft, transparent and odor free mask.\n• Smooth, feathered edges for patient comfort.\n• Mask fits snugly over the patient’s mouth and nose.\n• Adjustable elastic strap to fit over the patient’s head.\n• 600 ml reservoir bag. Non-return valves provided at inhale and exhale points to prevent carbon-dioxide retention.\n• Light weight reservoir improves the oxygen efficiency.\n• Individually packed\n item41 400 pices
43 1.42 B T Set with Luer Lock\n• Blood transfusion set with lure lock.\n• Long drip chamber, 200µm filter, to prevent any blood clots in passage.\n• Additional injection port.\n• Roller controller for adjustment of transfusion rate.\n• Smooth 150 cm long, kink resistant tube.\n Sterile, disposable, non-pyrogenic, individually \nPacked\n item42 70000 pices
44 1.43 Enteral Feeding Bag (DEHP Free):-\n• Enteral feeding bag intended for gastro-intestinal feeding.\n• 1.2 litre capacity bag.\n• Ice pouch is provided on the rear side of the bag for preserving the food for longer intervals of time.\n• Transfer set is directly connected to the bag.\n• Roller controller provided on the transfer set facilitates control on the administered feed.\n• The feeding bag is graduated to determine precisely the quantity of the administered feed.\n• Feeding bag is provided with a closure cap and also a hanger for safe hanging during and after use.\n• Sterile, individually packed in peelable pouch. item43 200 pices
45 1.44 Disposable Syringe with Needle Luer Lock -Size 2 ml\n• Manufactured from medical grade virgin polypropylene.\n• Threaded luer lock tip designed for safefit connection to female connector\n• Prominent graduation ensures dosage accuracy.\n• Clear transparent Barrel.\n• Rubber tipped piston\n• Thermoplastic elastomer gasket is inert that provides minimum friction during movement and prevents leakage and back flow.\n• Sharp triple facetted beveled tip needle.\n• Sterile, disposable, non-pyrogenic, individually packed.\n item44 300000 pices
46 1.45 Disposable Syringe with Needle Luer Lock- Size 5 ml\n• Manufactured from medical grade virgin polypropylene.\n• Threaded luer lock tip designed for safefit connection to female connector\n• Prominent graduation ensures dosage accuracy.\n• Clear transparent Barrel.\n• Thermoplastic elastomer gasket is inert that provides minimum friction during movement and prevents leakage and back flow.\n• Rubber tipped piston\n• Sharp triple facetted beveled tip needle.\n• Sterile, disposable, non-pyrogenic, individually packed.\n item45 300000 pices
47 1.46 Disposable Syringe with Needle Luer Lock -Size 10 ml\n• Manufactured from medical grade virgin polypropylene.\n• Threaded luer lock tip designed for safefit connection to female connector\n• Prominent graduation ensures dosage accuracy.\n• Clear transparent Barrel.\n• Thermoplastic elastomer gasket is inert that provides minimum friction during movement and prevents leakage and back flow.\n• Rubber tipped piston \n• Sharp triple facetted beveled tip needle.\n• Sterile, disposable, non-pyrogenic, individually packed. item46 300000 pices
48 1.47 • Disposable Syringe with Needle LuerLock\n• size: 20 ml.\n• Manufactured from medical grade virgin polypropylene.\n• Threaded luer lock tip designed for safefit connection to female connector\n• Prominent graduation ensures dosage accuracy.\n• Clear transparent Barrel.\n• Thermoplastic elastomer gasket is inert that provides minimum friction during movement and prevents leakage and back flow.\n• Sharp triple facetted beveled tip needle.\n• Sterile, disposable, non-pyrogenic, individually packed.\n• Rubber tipped piston\n item47 140000 pices
49 1.48 Disposable Syringe without Needle Luer Lock \n- Size 50 ml\n• Manufactured from medical grade virgin polypropylene.\n• Threaded luer lock tip designed for safefit connection to female connector\n• Prominent graduation ensures dosage accuracy.\n• Clear transparent Barrel.\n• Thermoplastic elastomer gasket is inert that provides minimum friction during movement and prevents leakage and back flow.\n• Sterile, disposable, non-pyrogenic, individually packed.\n• Rubber tipped piston.\n item48 20000 pices
50 1.49 Stainless steel prep razor:\n• Stainless Steel Prep Razor with Platinum Edge blade with Teflon Coating\n• High standard of safety and hygiene for pre-operational procedures\n• Safety cap for safety to the handler pre & post procedure\n• Comb located close to the blade, to lift the soft hair\n• Ribbed handle ensures a steady and efficient grip on the razor\n• Smoothly follows the natural contours of the body\n• Sterile EO, packed individually.\n item49 2000 pices
51 1.5 Volumetric burette set 150 ml\n• Soft, large caliberated, flexible burette chamber manufactured from PEmaterial, suitable for most of the pharmaceutic fluids.\n• Sharp piercing vented spike provided with built-in air inlet with bacterial barrier filter.\n• Micro drip set size of 60 drops/ml.\n• Easy to read scale with white contrast background.\n• Luer tip to prevent easy disconnection lock\n• Additional in-line injection port.\n• Drip rate controller with fail safe mechanism \n• Floating auto shut-off valve acts as volume indicator and automatically shuts off the path to prevent air embolism.\n• “Y” injection site for additional medication.\n• Patented design, no-kink device prevents kinking of tube.\n• Sterile, individually packed.\n item50 20000 pices
52 1.51 Under sheet PadSterile:\n• Soft non-woven top sheet with heavy duty absorbency. \n• Tear resistant, slip resistant, waterproof PE back sheet for leakageprevention. \n• Super absorbent polymer evenly spread to the core with sealed edges. \n• High absorbent tissue filled centre in the pad to lock the fluid immediately.\n• Quilted mat for better fluid dispersion. \n• Size: 60 x 90cm. \n• Strerile, Individually Packed\n item51 4000 pices
53 1.52 Flexible Tubing - 100% Silicone (Sterile) - 6mm\n• Highly flexible medical grade 100% silicone tubing, \n• Withstand temperature from - 85 degree Celsius to 250 degree Celsius. \n• Sizes : 6mm , Length 6 mtr\n• Sterilized by EO, Individually packed\n item52 2000 pices
54 1.53 Flexible Tubing - 100% Silicone (Sterile) - 8mm\n• Highly flexible medical grade 100% silicone tubing, \n• Withstand temperature from - 85 degree Celsius to 250 degree Celsius. \n• Sizes : 8mm , Length 6 mtr\n• Sterilized by EO, Individually packed item53 2000 pices
55 1.54 Air Mattress bubble pad and pump:\n• Air mattress to prevent bedsores \n• Kit consists of 1 Motor pump, 1 Air Bubble mattress & 1 repair kit\n• Portable and light weight motor\n• Sleek body with a low sound pump\n• Air Output = > 4.5 Ltr/ min, Cycle time = 12 min\n• PVC Pad consist of 130 bubble cells\n• Dimensions : 280cm(L), 90cm(W), 6.5cm(H)\n item54 100 pices
56 1.55 Nasojejunal tube:-\n• Metallic stylet inside the tube to be provided to facilitate the intubation & accurate placement.\n• Polyurethane enteral tube\n• Inert and non-reactive to gastric juices.\n• Dual port connector facilitates the use of catheter mount syringe as well as luer fitment of syringe.\n• 2 lateral eyes for efficient administration & aspiration.\n• The tube is marked at different intervals of 20,40,60,80 and 100 cm from the tip along the tube length for accurate placement.\n• Color coded for instant size identification\n• Open tip for easy placement\n• Size: Length 130 cm 12FG\nSterile, packed in peel open pack\n item55 2000 pices
57 1.56 Nasojejunal tube:-\n• Metallic stylet inside the tube to be provided to facilitate the intubation & accurate placement.\n• Polyurethane enteral tube\n• Inert and non-reactive to gastric juices.\n• Dual port connector facilitates the use of catheter mount syringe as well as luer fitment of syringe.\n• 2 lateral eyes for efficient administration & aspiration.\n• The tube is marked at different intervals of 20,40,60,80 and 100 cm from the tip along the tube length for accurate placement.\n• Color coded for instant size identification\n• Open tip for easy placement\n• Size: Length 130 cm 14 FG \n• Sterile, packed in peel open pack\n item56 2000 pices
58 1.57 Nasojejunal tube:-\n• Metallic stylet inside the tube to be provided to facilitate the intubation & accurate placement.\n• Polyurethane enteral tube\n• Inert and non-reactive to gastric juices.\n• Dual port connector facilitates the use of catheter mount syringe as well as luer fitment of syringe.\n• 2 lateral eyes for efficient administration & aspiration.\n• The tube is marked at different intervals of 20,40,60,80 and 100 cm from the tip along the tube length for accurate placement.\n• Color coded for instant size identification\n• Open tip for easy placement\n• Size: Length 130 cm 16 FG\n• Sterile, packed in peel open pack item57 2000 pices
59 1.58 Day & Night bag for incontinence:\n• Suitable for day & night use for incontinence.\n• Patented urovision chamber with complete closed drainage system which eliminates the risk of CAUTI\n• Available with T type bottom outlet.\n• Manufactured from soft clinical grade PVC sheeting\n• Diaphragm valve to prevent the backflow\n• Printed with easy to read scale\n• Universal connector with mid-stream sample port\n• Foldable hanger to hold provision chamber item58 1000 pices
60 1.59 100% Silicone external catheter:\n• Soft silicone male external catheter.\n• Non irritating, non reactive transparent material\n• Skin friendly adhesive\n• Cup shape applicator\n• Provided with soft adhesive strip\n• Ergonomically shaped\n• Sterile and individually packed\n• Sizes: 20 mm item59 2000 pices
61 1.6 100% Silicone external catheter:\n\n• Soft silicone male external catheter.\n• Non irritating, non reactive transparent material\n• Skin friendly adhesive\n• Cup shape applicator\n• Provided with soft adhesive strip\n• Ergonomically shaped\n• Sterile and individually packed\n• Sizes: 25mm,\n item60 2000 pices
62 1.61 100% Silicone external catheter:\n\n• Soft silicone male external catheter.\n• Non irritating, non reactive transparent material\n• Skin friendly adhesive\n• Cup shape applicator\n• Provided with soft adhesive strip\n• Ergonomically shaped\n• Sterile and individually packed\n• Sizes: 30mm\n item61 2000 pices
63 1.62 100% Silicone external catheter:\n• Soft silicone male external catheter.\n• Non irritating, non reactive transparent material\n• Skin friendly adhesive\n• Cup shape applicator\n• Provided with soft adhesive strip\n• Ergonomically shaped\n• Sterile and individually packed\n• Sizes: 35mm\n item62 2000 pices
64 1.63 Tri extension Needle free connector\n• Needle free I.V connector with triple extension for running three lines\nsimultaneously with rotating luer slip lock and three clamps.\n• Sterile, blister pack.\n• Low prime volume: 0.90 ml item63 2000 pices
65 1.64 Quadro extension Needle free connector\n\n• Needle free I.V connector with quadraple extension for running four lines\nsimultaneously with rotating luer slip lock and four clamps.\n• Sterile, blister pack.\n• Low prime volume: 1.20 ml item64 10000 pices
66 1.65 Mapleson F Jackson Rees modification\n• Good quality \n• Light Weight\n• Non-conductive disposable PVC plastic, T-piece with corrugate tubing\n• 1.8 m Circuit length\n• Low resistance\n• 500ml bag with APL Valve with 15f/22F connector.\n item65 200 pices
67 1.66 SMOOTHBORE CIRCLE BREATHING 22F\n• Good quality\n• Light weight\n• Non-conductive disposable PVC plastic\n• Flexible/light weight rigid connections\n• 1.6m long\n• Extra limb 1.6m long\n• 22F rebreathing bag\n• Safety cap\n item66 10000 pices
68 1.67 CIRCLE BREATHING (15F)\n• Good quality\n• Light weight\n• Non-conductive disposable PVC plastic\n• Flexible/light weight rigid connections\n• 1.6m long\n• Extra limb 1.6m long\n• 22F rebreathing bag\n• Safety cap\n item67 10000 pices
69 1.68 Breathing tube holder for Adult Circuits\n• Universal tube holder to support breathing circuit\n• Light weight & adjustable at various angles with one joint and under mat fixation \n• Adjustable height\n• For Adult item68 60 pices
70 1.69 Breathing tube holder for paediatric Circuits\n• Universal tube holder to support breathing circuit\n• Light weight & adjustable at various angles with one joint and under mat fixation \n• Adjustable height\nFor Paediatrics\n item69 62 pices
71 1.7 Breathing tube holder for Neonatal Circuits\n• Universal tube holder to support breathing circuit\n• Light weight & adjustable at various angles with one joint and under mat fixation\n• Adjustable height\nFor Neonates\n\n item70 60 pices
72 1.71 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 1\n item71 200 pices
73 1.72 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 1.5\n item72 202 pices
74 1.73 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 2\n item73 204 pices
75 1.74 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 2.5\n item74 206 pices
76 1.75 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 3\n item75 208 pices
77 1.76 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 4\n item76 210 pices
78 1.77 Supraglottic Airway (I-gel)\n• Airway device without an inflatable cuff\n• Incorporated Epiglottis blocker\n• With gastric channel\n• With Bite-block\n• Sizes: 5\n item77 212 pices
79 1.78 Flexible tip Laryngoscope:\n• Flexible tip Macintosh FO Laryngoscope with a tip adjustable through 70 degree\n• A lever controls the tip angle\n• Both ends of large fibre bundle whould be protected\n• Fits all ISO FO handles (Green handles)\n• All blades made of premium grade stainless steel in Matt finish\n• Should be Autoclavable\n• Complete with Mac blades sizes:1,2,3 and 4,with handle\n item78 4 pices
80 1.79 Breathing system for closed Anesthesia: \n• 1.Should be 1.6M Long disposable\n• 2.Should be made of Antimicrobial silver Material\n• 3.Should have an extra 0.8M limb\n• 4.Should have 2ltr Rebreathing bag\n• 5.Should have facility to deliver nebulisation, Without detaching the patient.\n item79 10000 pices
81 1.8 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Extra small item80 160 pices
82 1.81 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Small\n item81 160 pices
83 1.82 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Medium\n item82 160 pices
84 1.83 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Large item83 160 pices
85 1.84 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Extra large item84 160 pices
86 1.85 NIV Helmets:\n• Made of biocompatible plastic material\n• Connectors-22M/22F\n• Armpit fastening straps\n• Two sealed access ports for catheters from 3.5-7.0mm\n• Fitted with bi-directional anti-asphyxia valve\n• Airtight patient access port with screw cap\n• Light weight and transparent\n• Usable in both standing & supine position\n• Latex free\n• Sizes: Extra Extra large\n item85 160 pices
87 1.86 Oral care brush:\n• Out of package,ready to use\n• Moulded bristles\n• Flexible neck to ensure reduced force\n• Small head and long neck to easily reach target\n• Suction holes on top and between the bristles\n item86 1000 pices
88 1.87 Fluid shield N95 Mask\n• FluidShield* N95 filter Respirators are NIOSH0 approved and are designed to provide an effective facial fit as required for proper respiratory protection. NIOSH approved4-layer construction soft inner lining 100% natural rubber latex-free. Available with safety seal.\n item87 10000 pices
89 1.88 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes 0\n• Truly anatomical with unique flexible seal\n• Truly anatomical with unique flexible seal\n item88 40 pices
90 1.89 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes:1\n• Truly anatomical with unique flexible seal\nTruly anatomical with unique flexible seal\n item89 40 pices
91 1.9 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes:2\n• Truly anatomical with unique flexible seal\nTruly anatomical with unique flexible seal\n item90 40 pices
92 1.91 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes:3\n• Truly anatomical with unique flexible seal\nTruly anatomical with unique flexible seal\n item91 40 pices
93 1.92 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes:4\n• Truly anatomical with unique flexible seal\nTruly anatomical with unique flexible seal\n item92 40 pices
94 1.93 Antistatic Anatomical masks\n• Autoclavalveatleast 100 times\n• Latex free\n• Antistatic\n• Made up of natural rubber\n• Sizes:5 \n• Truly anatomical with unique flexible seal\nTruly anatomical with unique flexible seal\n item93 40 pices
95 1.94 Anti microbial breathing system heated wire:\n• Is a light weight and flexibeto minimize drag on circuits,1.5m heated inspiratory tubing,Silver impregnated, 0.5m humidifier connection tube, auto float humidification chamber with dual float sizes: pediatric,\n item94 1000 pices
96 1.95 Anti-microbial breathing system heated wire:\nIs a light weight and flexibeto minimize drag on circuits, 1.5m heated inspiratory tubing, Silver impregnated, 0.5m humidifier connection tube, auto float humidification chamber with dual float sizes: Neonatal\n item95 1000 pices
97 1.96 Patient Transfer Slide:\n• Should be light weight\n• Able to transfer between a bed and X-ray table, operating table, ambulance stretcher.\n• Patient transfer slide should be full body\n• Material should be Nylon\n• Should be foldable from Middle\n• Total weight of the slide should not be more than 3kg\n• Up to 200kg patient can be transferred by a single person\n• Chemical resistant material\n• It should be disinfected by surface disinfectant\n• Upper part should rotate and lower part should slide\n• Size 89x55 cm (+=3%) item96 40 pices
98 1.97 Mapleson C-Circuit\n• Light weight transparent for use in induction of Anaesthesia, resuscitation patient transport.\n• 2.0 Ltrs.Rebreathing bag with adjustable pressure limiting valve at patient’s end.\n• To provide adaptor for direct connection to flow meter.\n item97 1000 pices
99 1.98 Sodalime 5Kg. Jerry Can\n\n• Suitable for use with Anaesthetic breathing systems\n• To meet all requirement of Unites States Pharmacopoeia (USP)\n• Exhaustion to clearly indicate the Colur change (While to purple)\n• To contain less sodium hydroxide\n• Packed in jerry cans for longer lasting/easy storage, ISO certified\n• No powder, Minimum resistance, Hard surface, Greater absorption\n\n80 Boxes/\nJerry of 5kg each\n item98 160 pices
100 1.99 Bain coaxial antimicrobial Mapleson D with leak tester device\n• Disposable good quality light weight.\n• Silver nitrate impregnated\n• Internal volume 500 ml\n• With 2 litre rebreathing bag\nWith leak tester device Extra long coaxial Mapleson D system\n item99 1000 pices
101 2 Extra long coaxial Mapleson D system\n• Disposable good quality,light weight\n• Internal volume 2000ml\n• With 2 litre rebreathing bag\n• With leak tester device\n• For anaesthesia in CT scan units and MRI suits\n item100 1000 pices
102 2.01 Tpiece with reservoir bag and tubing\n• T piece with reservoir bag for visual indication\n• Able connect to ETT/TT\n• With O2 tubing\n• Reservior bag <500ML 2 litre\n item101 10000 pices
103 2.02 Filter Mask\n• Incurved face seal\n• Integral filter media to prevent aerosol escaping\n item102 1000 pices
104 2.03 Flat Operation Table Pad Universal\n\n• Operating theatre Table Pad should have a minimum thickness of 12mm.\n• Dimension of Ot pad should comply with minimum length X breadth of 500 x500mm.\n• It should have flat type single phase continuous surface at all along body length.\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete\n• pressure redistribution preventing bed sores, pressure, shear and frictional impact\n• It should be organic inert reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second\n item103 40 pices
105 2.04 Flat Operation Table Pad Universal\n\n• Operation theatre Table Pad should have a minimum thickness of 12mm\n• Dimensions of OT pad should comply with minimum length X breadth of 900 x 500mm.\n• It should have flat type single phase continuous surface along half of body length.\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferable less than fraction of second\n item104 40 pices
106 2.05 Flat Operation Table Pad Universal\n\n• Operation Theatre Table Pad should have a minimum thickness of 12mm\n• Dimensions of OT pad should comply with minimum length x breadth of 1150x500mm\n• It should have a single phase continuous surface with maximum pressure redistribution preventing bed sores all along body length.\n• It should have stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement.\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure, shear and frictional impact.\n• It should be organic, inert, reusable and should not bottom out with repeated usage.\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second.\n item105 40 pices
107 2.06 Open Head Ring Adolescent Size:\n\n• The positioning device should have donut (hole) at the centre with a minimum inner diameter of 80mm to provide air cushioning to head\n• It should have minimum outer diameter of 150mm along with vertical thickness of 30mm\n• It should have a single phase continuous surface contoured to complement head contours protecting skul neck and ears\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Mg at vertical angle of placement\n• It should be organic inert reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second\n item106 40 pices
108 2.07 Open Head Ring –adult Size:\n\n• The positioning device should have donut (hole) at the centre with a minimum inner diameter of 100mm to provide air cushioning to head\n• It should have minimum outer diameter of 200mm along with vertical thickenss of 40mm\n• It should have a single phase continuous surface contoured to complement head contours, protecting skull neck and ears.\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts\n• It should able to hold minimum weight of 200Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure, shear and frictional impact\n• It should be organic inert reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second\n item107 40 pices
109 2.08 Closed Head Ring Neonatal Size:\n• The positioning device should have a inner bulge at the centre with a minimum inner diameter of 45mm to provide covered support to soft skull\n• It should have minimum outer diameter of 90mm along with vertical thickness of 20mm\n• It should have a single phase continuous surface contoured to complement head contours protecting skull neck and ears.\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure shear and frictional impact \n• It should be organic, inert reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferable less than fraction of second\n item108 40 pices
110 2.09 Closed Head Ring – Adolescent Size:\n\n• The positioning device should have a inner bulge at the centre with a minimum inner diameter of 70mm to provide covered support to teen’s head\n• It should have minimum outer diameter of 140mm along with vertical thickness of 35mm\n• It should have single phase continuous surface contoured to complement head contours, protecting skull neck and ears\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts.\n• It should able to hold minimum weight of 200 Mg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores pressure shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second.\n item109 40 pices
111 2.1 Closed Head Ring – Adult Size\n\n• The positioning device should have a inner bulge at the centre with a minimum inner diameter of 100mm to provide covered support to teen’s head\n• It should have minimum outer diameter of 200mm along with vertical thickness of 45mm\n• It should have a single phase continuous surface contoured to complement head contours, protecting skull, neck and ears\n• It should have stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second\n item110 40 pices
112 2.11 Contoured Arm Board Pad:\n• The positioning device should have grooved structure with slight curved edge as a supporting surface for extended arm\n• The device should have minimum of length X width x height 500 X 130 X35mm\n• It should have a single phase continuous surface with enhanced pressure distribution on either side supporting the anatomy of arm and elbow as OT arm support device\n• It should have a stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts\n• It should able to hold minimum weight of 200Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure, shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second\n item111 40 pices
113 2.12 Flat Arm Board Pad:\n• The positioning device should have flat structure with no groove structure having multi site utility\n• The drive should have minimum of length of X width X height of 600 X 125X 12mm\n• It should have a single phase continuous surface with enhance pressure distribution resting the arm and elbow as OT extensor device\n• It should have stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure, shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second.\n item112 40 pices
114 2.13 Contoured Knee Pad:\n\n• The positioning device should have grooved structure with slight curved edge as a supporting surface for resting knee\n• The device should have minimum of length of X width X height 500 X 130X35mm\n• It should have a single phase continuous surface with enhanced pressure distribution on either side supporting contours of knee as padded support device\n• It should have stick on surface (without any chemical adhesive) at the bottom of the positioning device able to stick on the positioning belts\n• It should able to hold minimum weight of 200 Kg at vertical angle of placement\n• It should not leak while prick and able to support complete pressure redistribution preventing bed sores, pressure, shear and frictional impact\n• It should be organic, inert, reusable and should not bottom out with repeated usage\n• It should be made up of artificial cushioning gel with maximum rebounding capacity on withdrawal of pressure, preferably less than fraction of second \n• It should have a universal testing kit for testing the quality of material\n• It should comply with Standard Operating Procedures laid by Association of surgical Technologists for Operation Theatre Positioning Devices, self certification should be provided by the manufacturer.\n item113 50 pices
115 2.14 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen catheter 20, 23, 23G, dilator 5 Fr.,introducer needle 21G kit for injecting or infusing different solution and medications. Centimetre marking from 5 to 12 cm guide wire should be Nitinol (kink-resistant J guide wire).\nSize: 4-4.5 Fr. Length -6 cm \n item114 700 pices
116 2.15 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen catheter 20, 23, 23G, dilator 5 Fr.,introducer needle 21G kit for injecting or infusing different solution and medications. Centimetre marking from 5 to 12 cm guide wire should be Nitinol (kink-resistant J guide wire).\nSize: 4-4.5 Fr. Length -8 cm\n item115 700 pices
117 2.16 Neonatal Triple Lumen Radiopaque Polyurethane Triple Lumen catheter 20, 23, 23G, dilator 5 Fr.,introducer needle 21G kit for injecting or infusing different solution and medications. Centimetre marking from 5 to 12 cm guide wire should be Nitinol (kink-resistant J guide wire).\nSize: 4-4.5 Fr. Length -10 cm\n item116 600 pices
118 2.17 Neonatal Double Lumen Central VenousCatheter \n3Fr.\nNeonatal Double Lumen Polyurethanecentral venous Catheter Radiopaque for injecting or infusing different solutions and/or medications simultaneously. \nTray containing:\n1 double lumen catheter with centimetre markings from 4cm from distal tip, 1 short I.V cannula 24G – length 19mm, 1 introducer needle 22G, 1 straight guidewire, 2 dilators 3-3.5Fr. (Length 3cm and 5cm), 1 secondary fixation wing, 2 injection caps, 1 scalpel, 1 5ml syringe.\nSize: 3Fr. Length – 5-14 cm\n item117 100 pices
119 2.18 Triple Lumen Central Venous Catheter Kit (Adult)\n14G,18G,18G\nShould be Polyurethane Triple Lumen Catheter with flexible distal tip with J guide wire. Should be fully radiopaque with graduations at each centimetre from 5cm from the distal tip. Should have colored hubs with distal lumen with a large diameter (14G) for optimum flow, middle & proximal 18x18.\nAdult size – Fr. 7.5, Length 16cm \n item118 10000 pices
120 2.19 Triple Lumen Central Venous Catheter Kit (Adult)\n14G,16G,16G\nShould be Polyurethane Triple Lumen Catheter with flexible distal tip with J guide wire. Should be fully radiopaque with graduations at each centimetre from 5cm from the distal tip. Should have colored hubs with distal lumen with a large diameter (14G) for optimum flow, middle & proximal 18x18.\nAdult size – Fr. 8 to 8.5F, Length 16cm \n item119 10000 pices
121 2.2 Femoral Arterial Cannula (Adult) 20 G\nFemoral Arterial Cannula (Adult)Polyethylene transparent arterial catheter with radiopaque lines introduced using the Seldinger technique and equipped with a puncture needle allowing visualization of the arterial pulsations without blood spillage on needle insertion. The puncture needle should be fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). The needle should be fitted with a silicone BLS valve (BLS: bloodless system) to avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guide wire. \nSize- 20G, Length 8cm. \n item120 3000 pices
122 2.21 Femoral Arterial Cannula (Adult) 18 G\nOne transparent XRO Catheter (polyethylene), one introducer needle, should have one straight guide wire with flexible tip and anti-kink collar. \nSize- 18G- Length 10cm.\n item121 2000 pices
123 2.22 Femoral Arterial Cannula (Adult) 16 G\nOne polyurethane XRO Catheter with 5 to 20 cm marking on Catheter, one introducer needle, J Guide wire- advancer.Size-16G- Length 15cm.\n item122 1500 pices
124 2.23 One polyurethane XRO Catheter with 5 to 20 cm marking on Catheter, one introducer needle, J Guide wire- advancer. 16G-Length 20cm. item123 1500 pices
125 2.24 Peads Arterial Catheter Set/Kit 20G\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-20 G- Length 4 CM. \n item124 500 pices
126 2.25 Peads Arterial Catheter Set/Kit 20G\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-20 G- Length 6 CM.\n item125 500 pices
127 2.26 Peads Arterial Catheter Set/Kit 20G\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-20 G- Length 8, CM.\n item126 500 pices
128 2.27 Peads Arterial Catheter Set/Kit 20G\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-20 G- Length 20 CM.\n item127 500 pices
129 2.28 Peads Arterial Catheter Set 22G:\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-22G- Length 4 cm\n item128 400 pices
130 2.29 Peads Arterial Catheter Set 22G:\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-22G- Length 6, \n item129 400 pices
131 2.3 Peads Arterial Catheter Set 22G:\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guide wire with a flexible tip* one 50*50 cm drape sheet. \nSize-22G- Length 8 CM\n item130 400 pices
132 2.31 Peads Arterial Catheter Set 22G:\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-22G- Length 12 cm\n item131 400 pices
133 2.32 Peads Arterial Catheter Set 22G:\nFemoral Arterial Cannula (Paed.)Polyurethane with radio opaque line introduced by Seldinger technique with integral Polyurethane extension tube length 4.5 cm with fixation wing.\nPresented in a peel-pack.\n* 1 polyurethane Catheter* 1 introducer needle\n* 1 straight guidewire with a flexible tip* one 50*50 cm drape sheet. \nSize-22G- Length 20 cm\n item132 400 pices
134 2.33 Polyethylene pressure extension tube\nPolyethylene high pressure extension tube\nSize – 11, 200cm. \n item133 20000 pices
135 2.34 Polyethylene high pressure extension tube\nSize -30,200cm.\n item134 20000 pices
136 2.35 Polyethylene high pressure extension tube\nSize: –50, 200 Cm.\n item135 20000 pices
137 2.36 Polyethylene high pressure extension tube\nSize – 100, 200cm.\n item136 20000 pices
138 2.37 Polyethylene high pressure extension tube\nSize – 150 200cm.\n item137 20000 pices
139 2.38 Anti-biotic impregnated Triple Lumen Catheter\nImpregnated with rifampicin &miconazole with\nNitinol kink-resistant J guide wire.\nAdult Size: – (A) Fr. 7.5, Length – 16 & 20 cm\n item138 100 pices
140 2.39 Anti-biotic impregnated Triple Lumen Catheter\nImpregnated with rifampicin &miconazole with Nitinol kink-resistant J guide wire.\nPaed. Size:–(B) Fr. 4.5, Length – 6 & 12.5cm.\n item139 100 pices
141 2.4 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize –16G, \n item140 100 pices
142 2.41 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize – (B)18 G \n item141 100 pices
143 2.42 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize 20G \n item142 100 pices
144 2.43 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize – 22G\n item143 100 pices
145 2.44 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize 24 G \n item144 100 pices
146 2.45 PUR IV access Device with port \nPolyurethane IV access Device for Long term use in ICU.\nSize : 26G.\n item145 100 pices
147 2.46 Dressing:\nSterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film.\n5.5x7 cm\n item146 1000 pices
148 2.47 Dressing:\nSterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film\n 6.5x7cm\n item147 1000 pices
149 2.48 Dressing:\nSterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film.\n15x10cm\n item148 1000 pices
150 2.49 Dressing:\nSterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film.\n15x20cm\n item149 1000 pices
151 2.5 Dressing:\nSterile Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film.\n 30x15cm\n item150 1000 pices
152 2.51 Dressing:\nSterile, Stretchable, Permeable, Self-Adhesive, Transparent, Hypo- allergenic Dressing film.\n 30x45 cm\n item151 1000 pices
153 2.52 Quadrilumen Central Venous Catheter \n*Outer size: 8 to 8.5 Fr. \n* Port/Channel Size: 14/16/18/18G\n* Made of special grade material .\n*Length of catheter 15 cm.\n*18G Valve needle with side port\n* Semi Stiff dilator, \n* Nitinol Guide wire,\n * Safe Site connector with an option of ECG lead for location confirmation \n item152 400 pices
154 2.53 CVP Kit for Paed.\n20G,20G,22G\nPaediatric Triple Lumen Catheter.\nRadiopaque polyurethane central venous catheter inserted by Seldinger technique1 J type Nitinol guide wire for anti-kink. Centimetre markings from 5cm from the distal tip and Robert clamps. Supple distal tip.\nThe user can choose from 2 types of introducer, i.e. needle or I.V. Cannula.\nPresented in a rigid blister pack containing:\n1 triple-lumen catheter (5.5Fr),1 introducer needle 22G -Length 40 mm,1 short I.V. Cannula 22G, Length 25mm, 1 J type Nitinol guide wire for anti-kink, 2 dilators, 1 secondary fixation wing, 3 injection caps, 1 scalpel, 1 syringe 5ml\nSize: 5 to 5.5 Fr. Length - 8cm \n item153 1000 pices
155 2.54 CVP Kit for Paed.\n20G,20G,22G\nPaediatric Triple Lumen Catheter.\nRadiopaque polyurethane central venous catheter inserted by Seldinger technique1 J type Nitinol guide wire for anti-kink. Centimetre markings from 5cm from the distal tip and Robert clamps. Supple distal tip.\nThe user can choose from 2 types of introducer, i.e. needle or I.V. Cannula.\nPresented in a rigid blister pack containing:\n1 triple-lumen catheter (5.5Fr),1 introducer needle 22G -Length 40 mm,1 short I.V. Cannula 22G, Length 25mm, 1 J type Nitinol guide wire for anti-kink, 2 dilators, 1 secondary fixation wing, 3 injection caps, 1 scalpel, 1 syringe 5ml\nSize Size: 5 to 5.5 Fr. Length -12 to 13 cm\n item154 1000 pices
156 2.55 CVP Kit for Paed.\n20G,20G,22G\nPaediatric Triple Lumen Catheter.\nRadiopaque polyurethane central venous catheter inserted by Seldinger technique1 J type Nitinol guide wire for anti-kink. Centimetre markings from 5cm from the distal tip and Robert clamps. Supple distal tip.\nThe user can choose from 2 types of introducer, i.e. needle or I.V. Cannula.\nPresented in a rigid blister pack containing:\n1 triple-lumen catheter (5.5Fr),1 introducer needle 22G -Length 40 mm,1 short I.V. Cannula 22G, Length 25mm, 1 J type Nitinol guide wire for anti-kink, 2 dilators, 1 secondary fixation wing, 3 injection caps, 1 scalpel, 1 syringe 5ml\n Size: 5 to 5.5 Fr. Length - 15cm\n item155 1000 pices
157 2.56 Vial Adapter:\nFor withdrawal of sterile solution from sterile vial to maintain sterility. It should have FDA/ European CE (from notified body) certification.\n item156 4000 pices
158 2.57 Urine Bag with Non-return valve:\nUrine Bag with Non-return valve for critical ICU Patients “Individually packed sterile urine bag with Non-Return Valve, 2000 ml capacity, Needle free Kombicon port, 3micron hydrophobic filter, Integrated hanger and tube clamp, fitted with cross valve bottom outlet”\n item157 5000 pices
159 2.58 Fecal Management system:\nFlexiSeal: Fecal Management System should have highly flexible Silicone catheter with balloon and two ports for Irrigation and inflation (45ml), with finger cuff pocket for easy insertion. It should have odor barriers and must conform to sphincter anatomy, made of Latex-free and PVC- free components, with at least 3 Collection bags with odor control.with signal indicator.\n item158 1000 pices
160 2.59 Silicone Siloxanes Releaser:\n100% Blend of silicone sting free hypo-allergic non-alcoholic containing siloxanes adhesive releaser spray should be in 50ml bottle. \n item159 200 pices
161 2.6 Triple Lumen Catheter (Paediatric)\n20,22,22G\nTriple Lumen Catheter should be Polyurethane with flexible distal tip Nickel-Titanium Kink resistant with J guide wire. Should be fully radiopaque with graduations at each centimeter from 5cm from the distal tip. Should have colored hubs with distal lumen with a large diameter for optimum flow, middle & proximal 20x22x22.\nSize: – (A)5.5 Fr. Length 6cm\n item160 1000 pices
162 2.61 Triple Lumen Catheter (Paediatric)\n20,22,22G\nTriple Lumen Catheter should be Polyurethane with flexible distal tip Nickel-Titanium Kink resistant with J guide wire. Should be fully radiopaque with graduations at each centimetre from 5cm from the distal tip. Should have colored hubs with distal lumen with a large diameter for optimum flow, middle & proximal 20x22x22\nSize: – 5.5 Fr. Length 8cm\n item161 1000 pices
163 2.62 Triple Lumen Catheter (Paediatric)\n20,22,22G\nTriple Lumen Catheter should be Polyurethane with flexible distal tip Nickel-Titanium Kink resistant with J guide wire. Should be fully radiopaque with graduations at each centimetre from 5cm from the distal tip. Should have colored hubs with distal lumen with a large diameter for optimum flow, middle & proximal 20x22x22.\nSize: – 5.5 Fr. Length 13CM\n item162 1000 pices
164 2.63 Pressure Transducer kit for blood sampling:\nPressure Transducer kit \nInvasive Blood pressure transducer With Integrated unit for clinical accuracy\nDual mode of flushing, controlled Squeeze and snap tab\nCompletely Transparent for ease of Priming and Debubbling \nAvailable with flushing of 3cc/hr,Easy Zeroing\nClass IV Implanted Tested Tubing DEHP Free\nNeedless Systems with Ease of Blood sampling\nActivated by Luer Slip Syringe\nMinimal Risk of Infections and Cross Contamination\nInbuilt 6ml Reservoir Syringe to Facilitate Ample Clearing Volume\nPiston Is Protected by Silicon Sheath\nBonded connections to Minimize the Risk of Disconnection\n Single Line DPTKit\n item163 5000 pices
165 2.64 Pressure Transducer kit \nInvasive Blood pressure transducer With Integrated unit for clinical accuracy\nDual mode of flushing, controlled Squeeze and snap tab\nCompletely Transparent for ease of Priming and Debubbling \nAvailable with flushing of 3cc/hr,Easy Zeroing\nClass IV Implanted Tested Tubing DEHP Free\nNeedless Systems with Ease of Blood sampling\nActivated by Luer Slip Syringe\nMinimal Risk of Infections and Cross Contamination\nInbuilt 6ml Reservoir Syringe to Facilitate Ample Clearing Volume\nPiston Is Protected by Silicon Sheath\nBonded connections to Minimize the Risk of Disconnection\nDouble Line DPTKit\n item164 5000 pices
166 2.65 Patient Warming Blanket (Adult)- Full Body (100x195cm)\nPatient Warming Blanket (Adult) Full body Latex-free compatible with All leading enforced air patient warming systems.\nUnique Microscopic perforation to provide for even air distribution without the risk of residue.\nAmple dimensions to accommodate all patients.\nUniversal Inner port lines to ensure the hose remains firmly in the blanket.\nDimension: 100x195cm. \n item165 10000 pices
167 2.66 Patient Warming Blanket (Adult)- Lower body (100x120cm\nPatient Warming Blanket (Adult) Lower body Latex-free compatible with All leading enforced air patient warming systems.\nUnique Microscopic perforation to provide for even air distribution without the risk of residue.\nAmple dimensions to accommodate all patients.\nUniversal Inner port lines to ensure the hose remains firmly in the blanket. Generous amount of tape to secure blanket over abdomen.\nDimension: 100x120cm. \n item166 10000 pices
168 2.67 Patient Warming Blanket (Adult) \nUnder body full size: (206x87cm)\nUnder body Latex-free compatible with All leading enforced air patient warming systems.\nUnder body, full, unrestricted surgical access to the patient.\nUnique Microscopic perforation to provide for even air distribution without the risk of residue.\nAmple dimensions to accommodate all patients.\nUniversal Inner port lines to ensure the hose remains firmly in the blanket. Generous amount of tape to secure blanket over abdomen.\nDimension: 206x87cm. \n item167 10000 pices
169 2.68 Patient Warming Blanket (Paediatric) Full Body (100x120cm)\n\nFull body Latex-free compatible with All leading enforced air patient warming systems.\nUnique Microscopic perforation to provide for even air distribution without the risk of residue.\nAmple dimensions to accommodate all pediatrics patients.\nUniversal Inner port lines to ensure the hose remains firmly in the blanket. Generous amount of tape to secure blanket over abdomen.\nDimension: 100x120cm. Should be \n item168 5000 pices
170 2.69 Disposal Syringe 1ml Volume\n• 1ml syringle with needle \n• Marking to measure exact volume\n• Smooth needle for sueutaneous infiltration\nSterile packed\n item169 10000 pices
171 2.7 Ovassapianfiberoptic Intubating Airway\n• Designed for use with a fiberoptic bronchoscope\n• Latex free\n• Allows for removal without disconnecting endotracheal tube.\n• Flat lingual surface\n• Fits tube size 8 to 0mm ID item170 100 pices
172 2.71 • Should be able to work on Sonoclot (model SCP2)\n• Should cotain Glass Beads (Silica)\n• Should have capacity for 0.36ml of Blood sample\n• Should be able to use with Native Whole Blood or Citrated Whole Blood\nHypercoagulable/Hypocoagulable Screening\nPlatelet Function Assessment\nHyperfibrinolysis Screening\n• Should provide Quantitative results for Act, Clot Rate & Platelet Function results\n• Should also provide Qualitative & Quantitative information on Sonoclot Signature including\nFibrin Formation\nPlatelet Funciton\nHyperfibrinolysis\n item171 1000 pices
173 2.72 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n\n• PVC tube, latex free\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Sizes: 3.0,mm item172 200 pices
174 2.73 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n• PVC tube, latex free\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Sizes:3.5mm\n item173 200 pices
175 2.74 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n\n\n• PVC tube, latex free\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Sizes:4.0mm\n item174 200 pices
176 2.75 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n\n\n• PVC tube, latex fre\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Sizes :4.5mm item175 200 pices
177 2.76 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n\n• PVC tube, latex free\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Size:5.0mm\n item176 200 pices
178 2.77 Microcuff Endotracheal Tube for Oral/Nasal use in Paediatrics\n• PVC tube, latex free\n• Conforming to F-29 standards\n• Thermo-sesitive tube confirming to the tract anatomy\n• Kink-resistant\n• Strong tube walls to ensure proper ventilation\n• Distal small atraumaticfuff (high volume, low pressure type)\n• Soft cuff with air-tight seal between ETT and trachea\n• Radio-opaque line along entire length\n• Standard 15mm connector\n• Sterile individually packed in peelable blister pack\n• Sizes: 5.5mm\n item177 200 pices
179 2.78 Seldinger Based Chest Tube Set:\n• Seldinger placement technique chest straight tube with Echogenic needle,\n• Radiopaque catheter markings,\n• Serial dilators having radiopaque centimeter markings,\n• Various sizes 8 fr to 36 fr,\n• Needle holder cap in set\n item178 1000 pices
180 2.79 Disposable Infant T-Piece Resuscitator\nShould be flow controlled to deliver positive pressure ventilation to the infants.\n- Should have inbuilt colour coded manometer and pressure relief valve.\n- Should have ability to measure a more consistent, targeted in line Peak inspiratory Pressure (PIP) controller with override button and Positive End-Expiratory Pressure PEEP\n- Should have variabletactile PEEP Knob to increase or decrease the pressure.\n- Should be able to use with clear Anatomical or round silicon face mask\n item179 1000 pices
181 2.8 Offsert Connector Electrode\n• It should have high conductive wet gel to ensure reliable traces.\n• It should have superior adhesion to prevent false alarms\n• It should be design with offset connector to prevent artifacts from disrupting the readouts\n• It should have high quality Ag/AgCl sensor to ensure excellent trace quality\n• It should have combination of instant and long term adhesive which secures optimal fixation and precise recordings\n• It should have breathable microporous and hypoallergenic material which ensures optimal skin care\n• It should have size not more than 72 x 68 mm\n• Sizes –Adult\n item180 400 pices
182 2.81 Offsert Connector Electrode\n• It should have high conductive wet gel to ensure reliable traces.\n• It should have superior adhesion to prevent false alarms\n• It should be design with offset connector to prevent artifacts from disrupting the readouts\n• It should have high quality Ag/AgCl sensor to ensure excellent trace quality\n• It should have combination of instant and long term adhesive which secures optimal fixation and precise recordings\n• It should have breathable microporous and hypoallergenic material which ensures optimal skin care\n• It should have size not more than 72 x 68 mm\n• Sizes (B)Paed. \n item181 400 pices
183 2.82 Offsert Connector Electrode\n• It should have high conductive wet gel to ensure reliable traces.\n• It should have superior adhesion to prevent false alarms\n• It should be design with offset connector to prevent artifacts from disrupting the readouts\n• It should have high quality Ag/AgCl sensor to ensure excellent trace quality\n• It should have combination of instant and long term adhesive which secures optimal fixation and precise recordings\n• It should have breathable microporous and hypoallergenic material which ensures optimal skin care\n• It should have size not more than 72 x 68 mm\n• Sizes –Neonatal\n item182 200 pices
184 2.83 NIRS Sensor\nShould be compatible with MEDTRONIC NIRS Monitor.\n-Sizes - Adult, \n item183 4000 pices
185 2.84 NIRS Sensor\nShould be compatible with MEDTRONIC NIRS Monitor.\n-Sizes – Pediatric\n item184 3000 pices
186 2.85 NIRS Sensor\nShould be compatible with MEDTRONIC NIRS Monitor\nSizes - Neonatal\n item185 3000 pices
187 2.86 NIRS Sensor\nShould be compatible with NONIN NIRS Monitor.\nSizes - Adult,\n item186 400 pices
188 2.87 NIRS Sensor\nShould be compatible with NONIN NIRS Monitor.\nSizes - Pediatric\n item187 400 pices
189 2.88 NIRS Sensor\nShould be compatible with NONIN NIRS Monitor.\n-Sizes - Neonatal\n item188 200 pices
190 2.89 BIS Sensor\nIt should have four sensors element to capture, recognize and discard artifact.\nConnector should provide secure click-in connection with push button release\nIt should include an additional above eye element, which captures critical eye motion data, along with other important physiological signals.\nIt should have flexible design adjusts to different head sizes\nShould be supplied by authorized channel partner from principal company/ manufacture.\nElectrode Gel: Potassium Chloride (KCl) , latex free. \nSizes: ADULT \n item189 50000 pices
191 2.9 BIS Sensor:\nIt should have four sensors element to capture, recognize and discard artifact.\nConnector should provide secure click-in connection with push button release\nIt should include an additional above eye element, which captures critical eye motion data, along with other important physiological signals.\nIt should have flexible design adjusts to different head sizes\nShould be supplied by authorized channel partner from principal company/ manufacture.\nElectrode Gel: Potassium Chloride (KCl) , latex free. \n• Sizes: PEDIATRIC\n item190 50000 pices
192 2.91 Nellcor SPO2 Disposable Sensor \nSpecifications:\n• Should give accurate readings, even during low perfusion and most types of signal interference, including patient motion.\n• Should oversee a wide range of patients, from neonates to adults, including those who require long-term monitoring.\n• Should Improve the clinical relevance of the more challenging alarms and easily distinguish between minor transient events and clinically significant desaturations.\n• Should have Lo Sat expanded accuracy feature to accurately track SpO2 in low-saturation conditions.\n• Should Perform quick spot-checks or continuously monitor patients in any location.\n• Should have confidence in the accuracy with OxiMax™ technology and the extensive portfolio of Nellcor™ sensors.\n• Should have faraday shield to protect from Ambient Light. \n• Should have Disposable sensors for Adult, Pediatric, Neonates& Infants.\n• Should have digital calibration.\n item191 2000 pices
193 2.92 Sensor for Arterial Pressure Based Cardiac Out put Monitoring (Flotrac)\nDisposable Arterial pressure Cardiac Output sensor to provide CO,CI, SV, SVI,SVV, SVR & SVRI on continuous basis when connected with patient arterial pressure line.\nShould be individually packed.\nSterile & ready for use\nShouls be compatible with Vigileo monitor\n item192 1000 pices
194 2.93 Anti Bacterial Treated Surgical Tape:\nShould be made up of thin Non-woven fabric.\n- The fabric should be impregnated with antimicrobial compound to suppress the chances of growth of microbes.\n- Should meet B.P. standard.\nSizes- 1” x 10.00 mtrs\n item193 1000 pices
195 2.94 Anti Bacterial Treated Surgical Tape:\nShould be made up of thin Non-woven fabric.\n- The fabric should be impregnated with antimicrobial compound to suppress the chances of growth of microbes.\n- Should meet B.P. standard.\nSizes: 2” x 10.00 mtrs\n item194 1000 pices
196 2.95 Anti Bacterial Treated Surgical Tape:\nShould be made up of thin Non-woven fabric.\n- The fabric should be impregnated with antimicrobial compound to suppress the chances of growth of microbes.\n- Should meet B.P. standard.\nSizes: 3” x 10.00 mtrs\n item195 1000 pices
197 2.96 Anti Bacterial Treated Surgical Tape:\nShould be made up of thin Non-woven fabric.\n- The fabric should be impregnated with antimicrobial compound to suppress the chances of growth of microbes.\n- Should meet B.P. standard.\nSizes: 4” x 10.00 mtrs\n item196 1000 pices
198 2.97 Oxygen Recovery Kit\nIt should be specially designed kit with ‘T’ shaped connector for delivering oxygen. .\nIt should have 15 mm connector to fit all tracheal tubes.\nIt should have suction port at elbow to facilitate oro-bronchial suctioning without disconnecting the patient from oxygen source.\nIt should have two meter long star lumen tube to enable to connect the T connector with oxygen source.\nDistal end should be open for exhaling the waste gases.\n item197 500 pices
199 2.98 Colorimetric Disposable CO2 Detector\nFor patients from 250gm to 15+kg. Body weight.\n• Should have the facility of activation by pull tab Technique.\n• Should be able to work for 24 hours once activated by pulling tab.\n• Should be able to indicate- Blue green & yellow colour.\n• Should have larger CO2 viewing window.\n• Should have 15mm I.D. Standard Taper at Patient End & 15mm O.D. Standard Taper at\nCircuit End.\n• Sizes: Infant\n item198 400 pices
200 2.99 For patients from 250gm to 15+kg. Body weight.\n• Should have the facility of activation by pull tab Technique.\n• Should be able to work for 24 hours once activated by pulling tab.\n• Should be able to indicate- Blue green & yellow colour.\n• Should have larger CO2 viewing window.\n• Should have 15mm I.D. Standard Taper at Patient End & 15mm O.D. Standard Taper at\nCircuit End.\n• Sizes:, (B) Paediatric\n item199 400 pices
201 3 For patients from 250gm to 15+kg. Body weight.\n• Should have the facility of activation by pull tab Technique.\n• Should be able to work for 24 hours once activated by pulling tab.\n• Should be able to indicate- Blue green & yellow colour.\n• Should have larger CO2 viewing window.\n• Should have 15mm I.D. Standard Taper at Patient End & 15mm O.D. Standard Taper at\nCircuit End.\n Sizes: Adult\n item200 400 pices
202 3.01 Hand Restraint\nShould be made up of soft cotton cloth absorbent material.\n• Should absorb any sweating by the patient , leaving them dry & comfortable.\n• By securing the limbs of the patients through these restraints, it shouldgently prevent the\npatient from disturbing iv lines and the endo- tracheal tubes and other cannulated fluid\ndministration/sampling device.\n item201 400 pices
203 3.02 Ankle Restraint\nShould bemade up of soft cotton cloth absorbent material.\n• Should be able to absorb any severe sweating by the patients so as to leave them dry and\ncomfortable.\n• Should be able to secure the limbs of the patients through these restraints to gently prevent\nthe patient from disturbing iv lines and the endo- tracheal tubes and other cannulated fluid\nadministration/sampling device\n• Should bemade up of soft cotton cloth absorbent material.\n• Should be able to absorb any severe sweating by the patients so as to leave them dry and\ncomfortable.\n item202 400 pices
204 3.03 Washable Polymer Material Silicon Gel Tape\nShould be made up of washable & breathable Polymer fabric.\n-Should have Bi-directional tear-ability.\n-Should be hand tearable only &do not require the use of scissor or other instrument for cutting.\n-Should be breathable.\n- Should have Silicon gel coating for good adhesion.\n- Atraumatic fixation & ideal for skins where adhesive &non woven tapes are not recommended.\n- Should be Ideal for soft, sensitive & compromised skin.\n- Each roll should be individually packed.\n- Size: 1” x 1 mtrs.\n item203 800 pices
205 3.04 Washable Polymer Material Silicon Gel Tape\n\nShould be made up of washable & breathable Polymer fabric.\n-Should have Bi-directional tear-ability.\n-Should be hand tearable only &do not require the use of scissor or other instrument for cutting.\n-Should be breathable.\n- Should have Silicon gel coating for good adhesion.\n- Atraumatic fixation & ideal for skins where adhesive &non woven tapes are not recommended.\n- Should be Ideal for soft, sensitive & compromised skin.\n- Each roll should be individually packed.\n- Size:2” x 1 mtrs.\n\n item204 600 pices
206 3.05 Washable Polymer Material Silicon Gel Tape\nShould be made up of washable & breathable Polymer fabric.\n-Should have Bi-directional tear-ability.\n-Should be hand tearable only &do not require the use of scissor or other instrument for cutting.\n-Should be breathable.\n- Should have Silicon gel coating for good adhesion.\n- Atraumatic fixation & ideal for skins where adhesive &non woven tapes are not recommended.\n- Should be Ideal for soft, sensitive & compromised skin.\n- Each roll should be individually packed.\n- Size: 3” x 1mtrs.\n item205 600 pices
207 3.06 I.V. Midline Catheter\nShould be made up of special Polyutrethane material.\n-Should have soft &atrauamatic insertion.\n-Should be a safety device to prevent the chances of needle stick injuries.\n-Should have the injection port with colour coded cap for drug delivery.\n-The dwelling period of catheter in patient should be around 29 days.\n-Should have notched needle for quick blood view.\n-Should be easy to use.\n-Should have European CE.\n-Sizes : 16 G\n item206 800 pices
208 3.07 I.V. Midline Catheter\nShould be made up of special Polyutrethane material.\n-Should have soft &atrauamatic insertion.\n-Should be a safety device to prevent the chances of needle stick injuries.\n-Should have the injection port with colour coded cap for drug delivery.\n-The dwelling period of catheter in patient should be around 29 days.\n-Should have notched needle for quick blood view.\n-Should be easy to use.\n-Should have European CE.\n-Sizes : 18G.\n item207 800 pices
209 3.08 I.V. Midline Catheter:\nShould be made up of special Polyutrethane material.\n-Should have soft &atrauamatic insertion.\n-Should be a safety device to prevent the chances of needle stick injuries.\n-Should have the injection port with colour coded cap for drug delivery.\n-The dwelling period of catheter in patient should be around 29 days.\n-Should have notched needle for quick blood view.\n-Should be easy to use.\n-Should have European CE.\n-Sizes 20 G.\n item208 800 pices
210 3.09 I.V. Midline Catheter\nShould be made up of special Polyutrethane material.\n-Should have soft &atrauamatic insertion.\n-Should be a safety device to prevent the chances of needle stick injuries.\n-Should have the injection port with colour coded cap for drug delivery.\n-The dwelling period of catheter in patient should be around 29 days.\n-Should have notched needle for quick blood view.\n-Should be easy to use.\n-Should have European CE.\n-Sizes 22 G.\n item209 600 pices
211 3.1 Airway Exchange Catheter\nAirway Exchange Catheter should have adaptors to connect with Manual Resuscitator bag and ventilator.\n-Should have two holes on distal end for ventilation.\n- Should have cm. markings on the catheter.\nSizes:– 8 Fr. and 45 Cm. \n item210 20 pices
212 3.11 Airway Exchange Catheter\nAirway Exchange Catheter should have adaptors to connect with Manual Resuscitator bag and ventilator.\n-Should have two holes on distal end for ventilation.\n- Should have cm. markings on the catheter.\n- -Sizes: 11Fr. 14Cm item211 20 pices
213 3.12 Airway Exchange Catheter should have adaptors to connect with Manual Resuscitator bag and ventilator.\n-Should have two holes on distal end for ventilation.\n- Should have cm. markings on the catheter.\n- -Sizes 19Fr. 83cm.\n item212 20 pices
214 3.13 Ventilating Bougie With Stylet\n Intubating Catheter should have adaptors to connect with Manual Resuscitator bag and ventilator. - - Should have stainless steel stylet.\n- Should have two holes on distal end for ventilation.\n-Sizes: (A)14Fr. & 70cm, \n- Should have Cm. markings on the catheter.\n item213 20 pices
215 3.14 Ventilating Bougie With Stylet\nIntubating Catheter should have adaptors to connect with Manual Resuscitator bag and ventilator. - - Should have stainless steel stylet.\n- Should have two holes on distal end for ventilation.\n-Sizes: 8Fr. and 35cm.\n- Should have Cm. markings on the catheter.\n item214 20 pices
216 3.15 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula.14 G\n item215 400 pices
217 3.16 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula. 16G\n item216 400 pices
218 3.17 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula 18 G\n item217 400 pices
219 3.18 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula. 20G\n item218 400 pices
220 3.19 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula. 22G \n item219 400 pices
221 3.2 BACK FLOW IV Cannula:\nIt should be made up of polytetrafluoroethylene (PTFE) Insta flash needle technology for faster visualization or flashback by notch, Cannula contains aLuer_lock plug attached to the flow control plug, is a disposable device. Has an injection port and flexible wings to support the cannula- 24 G\n item220 400 pices
222 3.21 Eylid Occlusion Dressings\n• Size: Paediatric\n• Material-100% Polyurethane clear film layer \n• Polyster Non –woven fabric \n• Solvent base Acrylic adhesive\n• Sterilized with Ethylene Oxide \n• 1005 Latex free dual zone with central window transparent \n• Packed in Medical grade paper and laminate pouch \n• Skin Friendly \n item221 500 pices
223 3.22 Eylid Occlusion Dressings\n• Size: Adult\n• Adult Size-3.7cm x 9.3cm\n• Material-100% Polyurethane clear film layer \n• Polyster Non –woven fabric \n• Solvent base Acrylic adhesive\n• Sterilized with Ethylene Oxide \n• 1005 Latex free dual zone with central window transparent \n• Packed in Medical grade paper and laminate pouch \n• Skin Friendly\n item222 500 pices
224 3.23 Endotracheal Tube Plain\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes:(A) 2.5\n item223 400 pices
225 3.24 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 3.0,\n item224 440 pices
226 3.25 Endotracheal Tube Plain:\n\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 3.5\n item225 440 pices
227 3.26 Endotracheal Tube Plain\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 4.0\n item226 440 pices
228 3.27 Endotracheal Tube Plain:\n\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 4.5\n item227 440 pices
229 3.28 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peel able blister pack.\n Sizes: 5.0\n item228 440 pices
230 3.29 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 5.5\n item229 440 pices
231 3.3 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 6.0\n item230 440 pices
232 3.31 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 6.5,\n item231 440 pices
233 3.32 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes:7.0\n item232 440 pices
234 3.33 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\nSize:7.5\n item233 440 pices
235 3.34 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 8.0 Cm item234 440 pices
236 3.35 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n 8.5 CM\n item235 440 pices
237 3.36 Endotracheal Tube Plain:\n• Manufactured from thermo-sensitive material which conforms to body contours at body temperature. PVC\n• Kink resistant and transparent material to prevent occlusion in the tube bore.\n• Nasoral tip suitable for nasal/ oral intubation.\n• Murphy eye with smooth edges and tip to reduce any trauma.\n• Radio-opaque line throughout the length of the tube for X-ray detection and assistance in placement.\n• Should have 1cm marking from tip to base for proper fixation.\n• Proximal end is fitted with standard 15 mm connector.\n• Sterile individually packed in peelable blister pack.\n 9.0\n item236 400 pices
238 3.37 Endotracheal Tube Cuffed:\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 2.5\n item237 200 pices
239 3.38 Endotracheal Tube Cuffed:\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 3\n item238 200 pices
240 3.39 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 3.5\n item239 200 pices
241 3.4 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 4\n item240 200 pices
242 3.41 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 4.5\n item241 200 pices
243 3.42 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 5\n item242 200 pices
244 3.43 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 5.5\n item243 200 pices
245 3.44 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 6 \n item244 200 pices
246 3.45 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 6.5\n\n item245 200 pices
247 3.46 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 7\n item246 200 pices
248 3.47 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 7.5\n item247 200 pices
249 3.48 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\n Sizes: 8\n item248 200 pices
250 3.49 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 8.5\n item249 200 pices
251 3.5 Endotracheal Tube Cuffed\n• Thermo-sensitive tube conforms to the tract anatomy. PVC tube latex face\n• Conforms to F-29 standards.\n• Kink resistant tube for patient safety.\n• Strong tube walls to ensure proper ventilation.\n• Murphy eye with polished smoothness for atraumatic intubation and extubation.\n• High-volume, low pressure cuff.\n• Soft cuff air tight fit between the tube and trachea.\n• Should have 1cm markings from tip to base for proper fixation\n• Wide black ring above cuff for visual indication of tube passing the vocal cords to aid in placement.\n• Radio-opaque line for exact location.\n• Standard 15mm connector.\n• Sterile individually packed in peelable blister pack.\nSizes: 9\n item250 200 pices
252 3.51 Eyelid Occlusion Dressing\n• Size: 3.7cmx 9.3cm\n• Material-100% polyurethane clear Film layer \n• Polyster non –woven Fabric\n• Solvent based Acrylic adhesive\n• Styerilized with Ethylene oxide\n• 1005 Latex Free Dual zone with Central window Tranparent\n• Packed in medical grade paper and laminate pouch\n• Skin friendly \n• Size: (a ) Paediatric\n• Size Adult:-3.7cmx9.3cm\n item251 500 pices
253 3.52 Eyelid Occlusion Dressing\n• Size: 3.7cmx 9.3cm\n• Material-100% polyurethane clear Film layer \n• Polyster non –woven Fabric\n• Solvent based Acrylic adhesive\n• Styerilized with Ethylene oxide\n• 1005 Latex Free Dual zone with Central window Tranparent\n• Packed in medical grade paper and laminate pouch\n• Skin friendly \n• Size: Adult\n• Size Adult:-3.7cmx9.3cm\n item252 500 pices
254 3.53 Eye Pressure Shield:\n• Should be made of soft foam and rigid plastic shield .\n• Should have foam type no less than WA-18 H grade.\n• Foam Thickness should be 17 to 19 mm\n• Shield should have plastic type ,no less than ,triton TX 2001 with 3M Adhesive Type \n• Should have Transparent Plastic Central or Eye piece .\n• The size of eye pressure shield should be 400mm\n• The Eye pressure shield have weight not more than 50 gm.\n• The Eye pressure shield \n• The material should be skin friendly \n• Size: Paediatric\n• Should have a strap to secure its position\n item253 30 pices
255 3.54 Eye Pressure Shield:\n• Should be made of soft foam and rigid plastic shield .\n• Should have foam type no less than WA-18 H grade.\n• Foam Thickness should be 17 to 19 mm\n• Shield should have plastic type ,no less than ,triton TX 2001 with 3M Adhesive Type \n• Should have Transparent Plastic Central or Eye piece .\n• The size of eye pressure shield should be 400mm\n• The Eye pressure shield have weight not more than 50 gm.\n• The Eye pressure shield \n• The material should be skin friendly \n• Size: Adult. \n• Should have a strap to secure its position.\n item254 30 pices
256 3.55 Triple lumencentral venous catheter Kit (16G,18G,18G) Size: 7 Fr. \n• The triple lumen catheter should be of biocompatible polyurethanewith flexible distal tip \n• Should have flexible kink resistance J-tip guide wire \n• Should be fully radioopaque with graduation at each cm \n• Should have colour coded lock fittings.\n• Should have fixation wing at the channel junction for securing the catheter \n• Should have distal lumen of larger diameter (16G)&middle and proximal lumen of smaller diameter (18G)each).\n• Should have length of 8cm/13cm/16cm.\n• Kit should contain \nCentral venous catheter with clamp and injection caps.\nGuide wire \nDilator\nIntroducer needle \n5 ml syringe.\nFastener.\n• Tray\n item255 2000 pices
257 3.56 Triple lumen central venous catheter Kit\n (18G, 20G,20G) Size: 6.5 Fr. To 7.5 Fr.\n• The triple lumen catheter should be of biocompatible polyurethane with flexible distal tip \n• Should have flexible kink resistance J-tip guide wire ,\n• Should be fully radioopaque with graduation at each cm \n• Should have colour coded lock fittings.\n• Should have fixation wing at the channel junction for securing the catheter \n• Should have distal lumen of larger diameter (18G)&middle and proximal lumen of smaller diameter (20G)each).\n• Should have length of 8cm/13cm/16cm.\n• Kit should contain \nCentral venous catheter with clamp and injection caps.\nGuide wire \nDilator\nIntroducer needle \n5 ml syringe.\nFastener.\nTray\n item256 600 pices
258 3.57 Anti UV PM Line\nFor light sensitive drugs\n1.Should be spirally coiled tubing.\n2.Made of DEHP for polyethylene material\n3.Opaque tubing to prevent light exposure for light sensitive drugs .\n4.Size: 200 cm \n5.Lure Lock-One end male and other end Female ,\n 6.The terminal should also be opaque\n item257 600 pices
259 3.58 Anti UV PM Line\n1.Should be spirally coiled tubing.\n2.Made of DEHP for polyethylene material\n3.Opaque tubing to prevent light exposure for light sensitive drugs .\n4.Size: 150cm\n5.Lure Lock-One end male and other end Female ,\n 6.The terminal should also be opaque\n item258 600 pices
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail