| 1 | 1 | S&F in replacement fire hose reel drum ISI marked & confirming to relevent IS for 20 mm hose pipe of fire hadder all as directed. \nMake- GTech/Newage/JMC/Omex/ Mini Max or equivalent | | 3 | Each |
|---|
| 2 | 2 | M&L for Zubli clip for 20 mm dia hose reel pipe all as directed | | 10 | Each |
|---|
| 3 | 3 | M&L for fastner /Nut bolt for fixing the hose reel as per existing size all as directed | | 5 | Each Job |
|---|
| 4 | 4 | M&L for making hanging arrangment made out of FI holding clamp as per existing size dully painted for fire exingusher at each floor of building with suitable nut bolt & washers complete all as directed | | 5 | Each Job |
|---|
| 5 | 5 | S & F in replacement of stainless steel metal landing valve single headed 80 mm dia, flanged inlet 63 mm dia instant type female outlet complete with gun metal & cap & chain twist release type lug ISI marked & confirming to relevent IS complete all as directed. \nMake : GTech /Newage/Life Gaurd or eqvivalent | | 5 | Each |
|---|
| 6 | 6 | S&F in replacement for fire brigade inlet connection 2 way type ISI marked & confirming to relevent IS all as directed. Make : GTech /Newage/Life Gaurd or eqvivalent | | 2 | Each |
|---|
| 7 | 7 | S&F in replacement of 20 mm dia rubber hose pipe 30 Mtr long with fixing arrangement ISI marked & confirming to relevent IS complete all as directed. \nMake : GTech /Newage /Ronak/Life Gaurd or eqvivalent | | 2 | Each |
|---|
| 8 | 8 | S&F in replacement of 20 mm dia gun metal nozzle ISI marked & confirming to relevent IS complete all as directed. \nMake : GTech/Newage/JMC or equivalent | | 30 | Each |
|---|
| 9 | 9 | S&F in replacement of 63 mm stainless nozzle ISI marked & confirming to relevent IS complete all as directed. \nMake : GTech/Life Guard /Newage/JMC or equivalent | | 4 | Each |
|---|
| 10 | 10 | M&L for refilling of foam type fire extingusher 4.5 Kg capacity from authorised agency and submitting test report complete all as directed. | | 10 | Each |
|---|
| 11 | 11 | All as per item No 10 but dry chemical powder (DCP) fire extingusher 4.0 Kg capacity not older than six month from its date of manufacturing complete all as directed. | | 10 | Each |
|---|
| 12 | 12 | All as per item No 10 but CO2 type fire extingusher 4.5 kg capacity not older than six month from its date of manufacturing complete all as directed.. | | 5 | Each |
|---|
| 13 | 13 | S&F in replacement of manual call point with push button fired bride MS box duly painted sealed with glass including necessary electrical connection complete all as directed.\nMake - Agni/Alarm/NSD | | 1 | Each |
|---|
| 14 | 14 | S&F in replacement of low intensity hooter of 10 watt for warning of fire connected with central control panel installed in each zone complete all as directed. all as directed. \nMake- Agni/Alarm/NSD | | 1 | Each |
|---|
| 15 | 15 | S&F 4 mm thick glass for hose boxes any size as per site requirement complete all as directed. | | 2 | Sqm |
|---|
| 16 | 16 | S&F in replacement of MS ERW pipe 80 mm bore including cutting and welding , fittings for fire hydrant all as directed. \nMake- Jindal/Tata | | 10 | RM |
|---|
| 17 | 17 | M&L for painting of steel and iron surfaces such as rising/distribution lines /over head tank lines with two coat of synthetic enemelled paint after preparation of old painted surfaces all as directed. | | 5 | Sqm |
|---|
| 18 | 18 | Supply and fixing in replacement CO2 type fire extinguisher 4.5 Kg capacity ISI marked & confirming to relevent IS complete all as directed. \nMake- Omex or equivalent | | 5 | Each |
|---|
| 19 | 19 | All as per item No 18 but Dry chemical powder (DCP) type 4.0 Kg capacity complete all as directed. | | 5 | Each |
|---|
| 20 | 20 | M&L for butterfly valve 100 mm dia ISI marked & confirming to relevent IS complete all as directed \nMake- Leader/Zoloto/Sant | | 2 | Each |
|---|
| 21 | 21 | M&L for butterfly valve 150 mm dia ISI marked & confirming to relevent IS complete all as directed \nMake- Leader/Zoloto/Sant | | 3 | Each |
|---|
| 22 | 22 | S&F Non return valve (NRV) in replacement of size 150 mm ISI marked & confirming to relevent IS for fire hadder including nut,bolt & washer complete all as directed. Make - Kirloskar/Upadhyay /Kartar | | 2 | Each |
|---|
| 23 | 23 | S&F control globe valve of size 25 mm ISI marked & confirming to relevent IS for 20 mm dia hose pipe of fire hadder complete all as directed. \nMake- Leader/Zoloto/Sant | | 10 | Each |
|---|
| 24 | 24 | Supply and errect fire stand of suitable size made out of MS / angle iron/ chanel duly painted with two coats of synthetic enamelled post office red colour over a coat of red oxide as primer and lettering with white paint including providing the following all as directed by Engineer-in -charge:- a) Galvanised MS fire buckets 9 litre capacity - 04 No's b) Portable fire extinguisher CO2 type 4 Kg capacity - 04 No's \nMake:- Ceasefire / Firex/Omex (ABC) | | 4 | Each |
|---|
| 25 | 25 | Supply and fixing in replacement of hose box (Double Door) (30\"x 24\" x10\") 16 gauge suitable for 2 no. 15 mtr hose and 1 no. short branch pipe and 1 no hydrant complete in all respect. | | 10 | Each |
|---|
| 26 | 26 | Supply and fixing in replacement of flood light fitting by LED flood light 120 Watt aluminium die cast powder coated housing and frame , high efficiency long life LEDs, high purity PMMA lenses for superior performance , toughened glass with EPDM gaskets for IP 65 protection ,loop in loop out connector, complete assembly with LED driver and accessories pre wired up to terminal block in control gear compartment , intergal covered control gear compartment with connector 240 volt AC, complete with all acessories as specified and directed \nMAKE : LHB-120-CDL/60 OF Crompton/Philips | | 10 | Each |
|---|
| 27 | 27 | Supply and fixing in replacement of flood light fitting by LED flood light 200 Watt with unique design and thermal managemtn , high efficiency long life LEDs, high purity PMMA lenses for superior performance , toughened glass with EPDM gaskets for IP 65 protection ,loop in loop out connector, complete assembly with LED driver and accessories pre wired up to terminal block in control gear compartment , intergal covered control gear compartment with connector 240 volt AC, complete with all acessories as specified and directed.\nCat No LFLN-200-CDL/60-M of Make Crompton or its equivalents of Havells/Philips. | | 14 | Each |
|---|
| 28 | 28 | Supply, fixing and testing in replacement of Old unserviceable/ worn out street light fitting by pressure die cast powder coated LED street light/ security light 90 watt 240 volt Mains current 0.11 Amps, in built integrated electronic LED driver high purity PC fresnel diffuser with silicon gaskets IP 65 protection complete all as specified and directed including all accessories complete . \nmake: Cat part no. LSTN-90-CDL-A of make crompton or equivalent model in Phillips/Havells \n | | 10 | Each |
|---|
| 29 | 29 | Supply & fixing of LED Bulb of 9 W , to be fitted in batten holder 240 V single phase as specified and as directed . Make: Bajaj/Philips/havells | | 250 | Each |
|---|
| 30 | 30 | S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable with GI supporting wire of suitable size in replacement of old unseriveable conductor cable complete all as directed.\n Make : Plaza/Poly cab/Havells/fenolex | | 80 | RM |
|---|
| 31 | 31 | Supply & Fixing medium step type fan regulator 80 Watt, 240 Volt AC, style double colour series \"style medium step\" ISI marked complete all as specified and directed. \nMake: Anchor/havells. | | 80 | Each |
|---|
| 32 | 32 | Supply and fixing in replacement of old unserviceable FTL fitting by LED light fitting trend wall mounted batten with extruded aluminum housing with intregated LEd driver with LED tube aluminum extrusion 18 watt complete all as directed.\nMake:Bajaj/ Philips/ Havells.\n | | 80 | Each |
|---|
| 33 | 33 | Supply only self adhesive PVC electrical insulation tape, ISI Marked, conforming to IS 7809, Part - 3, Section -1 of size as under :-\n(i) Length - 8 Mtr\n(ii) Width - 18/19 mm\n(iii) Thickness - 0.125 mm\nMake - Steelgrip/Anchorgrip/Miracle or as approved by GE(I) | | 150 | Each |
|---|
| 34 | 34 | Supply, fixing and testing in replacement of Old unserviceable/ worn out LED T8 Retrofit Tube light:Tara Series.LED T8 retrofit light 20 watt 240 volt,Light source SMD LED array having IP 6X protection complete, all as specified and directed including all accessories complete all as directed.\nCat part no. of make cat part no. of Crompton: LTT8-20 or equivalent model in Phillips. | | 200 | Each |
|---|
| 35 | 35 | Dismantling fuel pump, radiator assembly, and other accessories of DG sets installed at Pump House No 04 and 05 at R V Colony under GE (I) R&D Kanpur all as specified and directed by Engr- In -Charge. | | 1 | Each Job |
|---|
| 36 | 36 | Cleaning and overhauling of Fuel pump including replacement of SET OF HIGH PRESSURE PIPES (DHA394) of diesel engine all as specified and directed by Engr- In -Charge. | | 1 | Each Job |
|---|
| 37 | 37 | Cleaning of radiator assy including leakage rectification, replace ment of hose pipe and minor spares all as specified and directed by Engr- In -Charge. | | 1 | Each Job |
|---|
| 38 | 38 | Cleaning of fuel tank assy including leakage rectification, replace ment of fuel indication pipe/ glass all as specified and directed by Engr- In -Charge. | | 2 | Each Job |
|---|
| 39 | 39 | Servicing of Diesel generating set as per manufacturers instruction including replacement of all defective parts required for making smooth functional of the DG Set complete all as directed by Engr-in-Charge. | | 2 | Each Job |
|---|
| 40 | 40 | Supply & fixing Engine START PUSH BUTTON - SCHNIDER MAKE (XB5AA31N) all as directed by Engr-in-Charge. | | 2 | Nos |
|---|
| 41 | 41 | Supply & fixing Engine STOP PUSH BUTTON - SCHNIDER MAKE (XB5AA31N) all as directed by Engr-in-Charge. | | 2 | Nos |
|---|
| 42 | 42 | Supply & fixing RED, GREEN & YELLOW INDICATION LAMP 12V DC all as directed by Engr-in-Charge. | | 2 | SET |
|---|
| 43 | 43 | Supply & fixing LUB OIL FILTER ELEMENT all as directed by Engr-in-Charge. | | 2 | Each |
|---|
| 44 | 44 | Supply & fixing set of fuel filter ( primary and secondary) element all as directed by Engr-in-Charge. | | 2 | Each set |
|---|
| 45 | 45 | Supply & fixing fuel supply pipe line of fuel tank to FIP of DG set all as directed by Engr-in-Charge. | | 1 | Each set |
|---|
| 46 | 46 | Supply & changing engine oil suitable for diesel engine of DG set installed at RV Colony all as directed by Engr-in-Charge. | | 50 | Ltr |
|---|
| 47 | 47 | Supply and Fix Change over Switch, on load type in open execution, front handle operated, 415V with rating of 160 A , four pole including fixing in panel with all accessaries complete all as specified and directed by GE (I).\nMake Indo Asian/ Legrand / Havells/L&T as approved by GE (I).\n | | 1 | Each |
|---|
| 48 | 48 | Supply, fixing and testing in replacement of Old unserviceable/ worn out street light fitting by pressure die cast powder coated LED street light 100 watt 240 volt , in built integrated electronic LED driver toughened glass with silicon gaskets for IP 65 protection complete all as specified and directed including all accessories complete \nMake : Bajaj cat No 169885 /Crompton cat no LSTN 100 CDL- A/ Havells Cat No LHETAXU7PA6J120 as approved by GE (I). \n | | 25 | Each |
|---|
| 49 | 49 | Supply, fixing and testing in replacement of Old unserviceable/ worn out street light fitting by pressure die cast powder coated LED street light 60 watt 240 volt , in built integrated electronic LED driver toughened glass with silicon gaskets for IP 65 protection complete all as specified and directed including all accessories complete \nMake : Bajaj Cat No 169950/ Havells cat no LHETBXU7PA7B060/ Crompton Cat No LSTP- 60-CDL as approved by GE (I). \n | | 40 | Each |
|---|
| 50 | 50 | Supply, fixing and testing in replacement of Old unserviceable /worn out security light fitting by Out Door LED Security light fitting 30 W of suitable size including connection with 3 core sheathed PVC insulated cable white colour not less than 0.5 sqmm not more than 0.50 m long complete all as specified and directed. \nMake :Bajaj Cat No 169887/ Havells Cat No LHETBXU7PAIS030/ Crompton Cat No LSTL-30-CDL as approved by GE (I). \n | | 40 | Each |
|---|
| 51 | 51 | Supply, fixing and testing in replacement of Old unserviceable/ worn out flood light fitting by Turbo LED flood light 180 watt 240 volt with secondary optics made in pressure die cast housing a LED flood light high efficiency in built integrated electronic LED driver complete all as specified and directed including all accessories complete all as directed.. \nMake :Bajaj Cat No 169658/ Havells Cat No LHFPCZBFP46J180/ Crompton Cat No LSFO-200-CDL/60 as approved by GE (I). \n | | 12 | Each |
|---|
| 52 | 52 | Supply, fixing and testing in replacement of Old unserviceable/ worn out flood light fitting by Turbo LED flood light 120 Watt, 240 volt with secondary optics made in pressure die cast housing and heat sink in aluminium extursion with IP 66 protection high efficiency in built integrated electronic LED driver complete all as specified and directed including all accessories complete . \nMake : Bajaj Cat No 169641/ Havells Cat No LHFPCZBFP46J120/ Crompton Cat No LFLN-150-CDL/60 as approved by GE (I). \n | | 12 | Each |
|---|
| 53 | 53 | Supply, fixing and testing in replacement of Old unserviceable/ worn out post top lantern with LED post top lantern 40 Watt by pressure die cast powder coated LED high efficiency in built integrated electronic LED driver IP 65 protection complete all as specified and directed including all accessories complete . \nMake : Bajaj Cat No 112364/ Havells cat no LHEVBGP7PN6K040/ Crompton Cat No LPTO-40-CDL as approved by GE (I). | | 4 | Each |
|---|
| 54 | 54 | Supply, fixing and testing in replacement of Old unserviceable street light timer with astronomical timelite switch distribution board of capacity 40Amp, 230 volts, 50 Hzs including all accessaries fitted on pole complete all as specified and directed . \nMake : IndoAsian/Hager/ Bajaj/Havells as approved by \nGE (I). | | 2 | Each Job |
|---|
| 55 | 55 | Dismantling & taking down unserviceable street light/security light fitting of SV/MV type of 150/250/400 Wattage or T- 5 Street Light luminaires or 2x36 watt CFL Fitting of any type from existing pole/building from height not more than 11.0 metre from ground level for repair/replacement of worn out / burnt accessories and refixing at same location after making it serviceable including testing and connecting to street light feeder complete in all respect and as directed by Engr-in-Charge. \nNote :- Spare parts/service wire/control wiring required to make the light fittings serviceable shall be measured and paid separately as \"supply only\" under relevant items. \n | | 30 | Each\nJob |
|---|
| 56 | 56 | Supply of Metal halide tubular clear lamp (single ended), Base cap - E 40 type of 150 Watt suitable for 240 VAC supply Lamp Type : 150W MH SET\nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 4 | Each |
|---|
| 57 | 57 | Supply of Metal halide tubular clear lamp (single ended), Base cap - E 40 type of 250 Watt, suitable for 240 VAC supply Lamp Type : 250W MH SET-6000K\nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 4 | Each |
|---|
| 58 | 58 | Supply of Metal halide tubular clear lamp (single ended), Base cap - E 40 type of 400 watt, suitable for 240 VAC supply Lamp Type : 400W (BT) 6000 K , \nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 8 | Each |
|---|
| 59 | 59 | Supply of T 5 Lamp of 24 Watt Cool day light of High efficiency/High out put suitable for 240 VAC supply Base cap G5 Type Lamp Type : 24WT5HO-6500K,\nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 10 | Each |
|---|
| 60 | 60 | Supply of high frequency \"regular\" electronic ballast slim, light in weight suitable for 2 x 24 watt T5 luminaires to improve power factor close to 0.98 having THD < 30 % complete all as specified and directed. \nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 5 | Each |
|---|
| 61 | 61 | Supply of open construction electromagnetic MH ballast consisting of high quality silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 150 Watt suitable for MH luminaires complete all as specified and directed.\n Make : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 3 | Each |
|---|
| 62 | 62 | Supply of open construction electromagnetic HPSV/ MH ballast consisting of high quality silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 250 Watt suitable for Metal halide luminaires complete all as specified and directed.\nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 3 | Each |
|---|
| 63 | 63 | Supply of open construction electromagnetic MH ballast consisting of high quality silicon steel lamination with argon welding, super enamelled copper wire wound, vacuum impreganated with white resin, terminal block with tapping for 220/240 Volt AC Supply of 400 Watt suitable for MH luminaires complete all specified and directed. \nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 9 | Each |
|---|
| 64 | 64 | Supply of electronic ignitor (superimposed) for integral type metal halide luminaires of 70/150/250/400 Watt suitable for MH Lamp upto 5 metre striking distance complete all as specified and directed.\nMake : Phillips/CG/ Bajaj/Havells as approved by GE (I). | | 9 | Each |
|---|
| 65 | 65 | Supply of FR PVC insulated, PVC sheathed flat twin core, solid aluminium conductor cable of size 2.5 sq mm for voltage grade upto 1100 volt confirming to IS- 694/1990 with latest amendments and ISI marked including removing old connection and making service connections to street light feeder \nMake: Polycab or its equivalent of EON (Indo Aian) / Havells/ Paragon Electron/ Plaza/Rallison as approved by GE(I). | | 60 | RM |
|---|
| 66 | 66 | Supply of FR PVC insulated, PVC sheathed flat twin core of stranded aluminium conductor cable/wire of size 6.0 sq mm for voltage grade upto 1100 volt confirming to IS- 694/1990 with latest amendments and ISI marked including removing old connection and making service connections to street light feeder \nMake: Polycab or its equivalent of EON (Indo Aian) / Havells/ Paragon Electron/ Plaza/Rallison as approved by GE(I). | | 50 | RM |
|---|
| 67 | 67 | Supply of metalised poly-propylene film capacitor as per IS 1569 for use in luminaires to improve power factor complete all as specified and directed of following capacity \nMake : CG or its equivalent of Surya/Havells/Epcos/Siemens as approved by GE(I) | | | |
|---|
| 68 | 68 | 20 Mfd, 250VAC for 150 watt MH fitting | | 2 | Each |
|---|
| 69 | 69 | 33 Mfd, 250VAC for 250 watt MH/SV fitting | | 2 | Each |
|---|
| 70 | 70 | 42 Mfd /250VAC for 400 W MH fitting | | 2 | Each |
|---|
| 71 | 71 | Supply & fixing street light bracket made out 32 mm dia bore Galvanised Iron pipe, light grade ISI marked of length not less than 1.2 metre, bend to required shape for holding the fitting including taking down the old bracket from existing pole/building complete all as specified and directed. Note:-Clamps ,Nut & Bolts for supporting the brackets shall be measured and paid separately under relevant item herein after. | | 10 | Each \nJob |
|---|
| 72 | 72 | Supply, fabrication, bending of mild steel flat iron to required shape and size as required/ directed including drilling hole, nuts, bolts and washers set of adequate size with one priming coat of red oxide with two finishing coat of aluminium paint and fixing on steel tubular pole including removing old flat iron for supporting G.I. tubing/bracket/protection pipe complete all as specified and directed. | | 10 | Kg |
|---|
| 73 | 73 | M & L for ACSR conductor at errected LT/HT pole for three phase distribution and sretching/stringing with due care after taking proper shut down from concern MES competent staff complete in all respect and as directed. | | 1 | Per Quintal |
|---|
| 74 | 74 | M&L for pre- fabricated street light junction /distribution box of size 200mm x250 mm with hinged cover system made of MS Sheet/ CRCA sheet duly painted with two coats of synthetic enamelled paint over a coat of red oxide primer suitable for mounting on pole including fixing on pole with clamp 50x6 and nut, bolts and suitable size Aluminium bus bar 02 Nos (Phase,N) connecting incoming and out going connection with proper lugging as latest practice acting as control circuit for street light including MCB SP 'C' 6 Amps for control of s/light complete all as specified and directed. | | 5 | Each |
|---|
| 75 | 75 | Routine and periodical work required for trimmimng/cutting of tree branches of any gruth,touching/obstructing the overhead lines of HT/LT Pole of three phase distribution system at palces not more than 40 meter span distance so as to keep minium 2.0 m clearence all arround the lines and poles with due care after taking proper electric shut down from concern JE E/M including disposal thereoff (trimmed btanches) to a distance not exceeding 500m complete all as specified and directed. | | 150 | Each Span |
|---|
| 76 | 76 | Labour work required for restretching/restringingof existing loos/sagged ACSR/GI Conductor of HT/LT OH lines of three phase distribution system by opening binding wire from insulator as fixed on pole and restring OH Line with proper binding with insulator by using additional binding wire/conductor not less than 2.0 mm dia with due care using safety belt etc after after taking proper electric shut downfrom concern JE E/M complete all as directed by Engr-in-charge. | | 2500 | RM |
|---|
| 77 | 77 | M & L for GI Conductor/wire 4.00 mm dia 8.00 swg beside to neutral conductor at errected LT/HT pole for three phase distribution and sretchinf stringing with due care after taking proper shut down from concern MES competent staff complete in all respect and as directed. | | 130 | Kg |
|---|