| 1 | 1 | SCHEDULE \"A\" Part - I (BUILDING WORKS)\nDetails of prepriced schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 2 | 2 | SCHEDULE \"A\" PART-II ( EARTH WORK AND SITE CLEARENCE) \nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 3 | 3 | SCHEDULE \"A\" PART-III (INTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 4 | 4 | SCHEDULE \"A\" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 5 | 5 | SCHEDULE \"A\" PART-V (ROAD/PATH/CULVERT)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 6 | 6 | SCHEDULE \"A\" PART-VI (SEWAGE DISPOSAL)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 7 | 7 | SCHEDULE \"A\" PART-VII (AREA DRAINAGE)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 8 | 8 | SCHEDULE \"A\" PART-VIII (EXTERNAL WATER SUPPLY)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 9 | 9 | SCHEDULE \"A\" PART-IX (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 10 | 10 | SCHEDULE \"A\" PART-X (REFRIGERATION AND AIR CONDITIONING)\nDetails of prepriced Schedule is given in tender documents. | | 1 | Lump sum |
|---|
| 11 | 11 | SCHEDULE \"A\" PART -XI (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under Col.' E ' signifies this fact only. | | | |
|---|
| 12 | 11.01 | INTERNAL WATER SUPPLY\nS & F Two way bib tap 20 mm Make – Drizzel or equivalent | | 7 | Each |
|---|
| 13 | 11.02 | INTERNAL ELECTRIC SUPPLY\nS & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed.\nMake: Legrand Arteor Cat-Part No. 5734 43 or equivalent model of ABB (snieo) / L&T (Entice) / Wipro | | 1 | Each |
|---|
| 14 | 11.03 | S & F modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed. \nMake: Legrand Arteor Cart-Part No. 5734 26 or equivalent model of Precision | | 2 | Each |
|---|
| 15 | 11.04 | S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed.\nMake: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro | | 57 | Each |
|---|
| 16 | 11.05 | S & F 9 W LED lamp complete all as specified and directed.\nMake: BAJAJ Cat-Part No. 112407 BCLSB 10 WH or equivalent model of Havells, Philips or Wipro | | 9 | Each |
|---|
| 17 | 11.06 | S & F 20 W LED street light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of = 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, pole mounting with bracket 1.5 m long with including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. \nMake: BAJAJ Cat-Part No. BAJAJ 169829 BCLST 20W LED I or equivalent model of Havells, Philips or Wipro | | 4 | Each |
|---|
| 18 | 11.07 | S & F BEE five star rated energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. \nMake: Crompton Cat-Part No. ENTRUST50 or Havells Cat- Part No. ES-50 or equivalent model of Usha or BAJAJ | | 21 | Each |
|---|
| 19 | 11.08 | S & F energy efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. \nMake: Crompton Cat-Part No. VENTILUS 10\" or equivalent model of Usha, Havells or BAJAJ | | 9 | Each |
|---|
| 20 | 11.09 | S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.\nMake: Schneider, Legrand, Havells\n(a) 6 A, SP MCB, C- curve \n | | 15 | Each |
|---|
| 21 | 11.1 | (b) 16 A, SP MCB, C- curve | | 5 | Each |
|---|
| 22 | 11.11 | (c) 20 A, SP MCB, C- curve | | 5 | Each |
|---|
| 23 | 11.12 | (d) 32 A, DP MCB, C- curve | | 1 | Each |
|---|
| 24 | 11.13 | (e) 32 A, SPN MCB, C- curve | | 1 | Each |
|---|
| 25 | 11.14 | (f) 40 A, FP MCB, C- curve | | 1 | Each |
|---|
| 26 | 11.15 | M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel wire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed. | | 2 | Each |
|---|
| 27 | 11.16 | EXTERNAL ELECTRIFICATION\nSupply and lay double wall corrugated (DWC) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall , size 63mm outer dia for protection of UG cable, with all fittings laid in trenches / road / nallah or fixed along wall. poles or laid under PCC interlocking tiles including road cutting & making good, complete all as specified and as directed ny Engg in Charge (excavation and earth work shall be measured and paid seperately) \nMake : Rex/Poly/Gemini or equivalent.\n | | 50 | Rm |
|---|
| 28 | 11.17 | M & L for Earthing complete with galvanized steel pipe electrode , 40mm bore, medium grade, 2.5 metre length, buried directly and preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead 4mm dia galvanised iron or steel wire all as shown in electrical plate no. 2 of MES SSR part-1 to the earthing test point all as specified and indicated including testing on completion all as specified and directed.\nNOTE: cost of earth lead wire GI wire 4mm dia and GI pipe for protection of earth strip deemed to be included in unit rate up to 7.5 metre. | | 2 | Each |
|---|
| 29 | 11.18 | REFRIGERATION AND AIR CONDITIONING\nSupply and fix voltage stabilizing for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 140V to 280V, with output voltage stabilized at 230 Volt with accuracy of +/- 2.5% and of capacity 1.0 KVA.\nMake: V-Guard/Volina/AE/ Aplab. | | 2 | Each |
|---|