Special Repairs To Ac Sheets And Em Work In Building No 14 15 4 1 2 39 55 And 304 At Drdl Hyderabad, GE I R AND D KANCHANBAGH HYDERABAD-Telangana

Military Engineer Services-MES has published Special Repairs To Ac Sheets And Em Work In Building No 14 15 4 1 2 39 55 And 304 At Drdl Hyderabad. Submission Date for this Tender is 25-08-2020. Electromechanical Work Tenders in GE I R AND D KANCHANBAGH HYDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

23830825
Corrigendum : Special Repairs To Ac Sheets And Em Work In Building No 14 15 4 1 2 39 55 And 304 At Drdl Hyderabad
Open Tender
Indian
Telangana
GE I R AND D KANCHANBAGH HYDERABAD
25-08-2020

Tender Details

Special Repairs To Ac Sheets And Em Work In Building No 14 15 4 1 2 39 55 And 304 At Drdl Hyderabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Mar-2020 Bid Submission Start date corrigendum Date 08-04-2020
2 23-Mar-2020 Corrigendum Start date Date 16-04-2020
3 30-Mar-2020 Corrigendum date Date 13-05-2020
4 24-Apr-2020 AMENDMENT TO CRITICAL DATES Date 03-07-2020
5 17-Jun-2020 Start date postponed Date 06-08-2020
6 06-Aug-2020 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-08-2020
7 14-Aug-2020 End date Corrigendum Date 25-08-2020

Key Value

Document Fees
INR 1000 /-
EMD
INR 145600.0 /-
Tender Value
INR 80.40 Lakhs /-

BOQ Items

Name of Work: SPECIAL REPAIRS TO AC SHEETS AND E/M WORK IN BUILDING NO 14,15,41/2,39,55 AND 304 AT DRDL HYDERABAD
Sl. No. TEXT # Item Code / Make Quantity Units
1 1 Dismantling of asbestos cement (corrugated ,semi corrugated etc) sheets in roof covering including ridges ,north light roofing etc complete all as specified and directed.\n 3100 CUBIC METRE
2 2 Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet / trapezoidal steel sheet 0.50mm base metal thickness of any colour having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws and EPDM washers as specified, complete all as specified and directed.\n 3100 SQUARE METRE
3 3 Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm base metal thickness of any colour having tensile strength of 550 MPa as in ridges /roof covering/cladding to wall, fixed with self tapping screws and EPDM washers as specified, complete all as specified and directed.\n 100 SQUARE METRE
4 4 1.6 mm thick mild steel plain black sheet in water troughs ,gutters ,wall cladding , ducts etc cut to size profiles ,edges beaded if required ,holes punched incliding headed screws ,clout nails or rivets and fixed to steel members etc with plain 40mm lap joints or welded /riveted seams including bending ,turning etc as required including taking down existing one complete all as specified and directed.\n 37 SQUARE METRE
5 5 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.\n 1.51 QUINTAL
6 6 Mild steel work as in bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges, large hasps and staples , chains ,hand made sliding bolts, clamps ,hold fasts,wall ties,hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters,knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.\n 60 KILOGRAM
7 7 Mild steel work as in Hand rails, half round or other stock section or core for wooden hand-rail straight portion,drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts , posts and struts in fencing including cutting tops to shape as directed.,drilling holes,notching for wire, etc.flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165complete all as specified and directed.\n 1450 KILOGRAM
8 8 False ceiling with pre-coated standard GI angle ,Tee and grid sudpended with 4mm dia GI wire at 600 mm centre to centre ,angle of size 25x25x0.7mm fixed around ,main Tee and cross Tee of section 38x25x0.7mm with soffits clips ,holding and level clips with Gypsum board ceiling tiles of size 600mmx 600mm(or nearest size) of 12 mm thick with white paper layer on face side as per manufacturer's instructions and applying two coats of acrylic emulsion distemper over a coat of primer including taking down existing ceiling boards with grid complete all as specified and directed.\nMake/Manufacturer : Indian Gypsum/ Saint Gobain\n 1360 SQUARE METRE
9 9 Demolition of brick or stone masonry, built in cement mortar including in roof kerbs etc complete all as specified and directed.\n 8 CUBIC METRE
10 10 Walling of random uncoursed well bonded,bedded and solidly hearted built in cement mortar 1:6 complete all as specified and directed. 8 CUBIC METRE
11 11 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.\n\n 250 SQUARE METRE
12 12 Rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surfaces at any height and finishing the surface even and smooth with out using exta cement on internal walls complete all as specified and directed.\n\n 180 SQUARE METRE
13 13 Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces at any height and finishing the surface even and smooth with out using exta cement on external walls complete all as specified and directed.\n\n 155 SQUARE METRE
14 14 Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer over two coats of internal grade wall care putty ( total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed.\n 3140 SQUARE METRE
15 15 Preparation of new plastered surfaces of walls and applying two coats of acrylic emulsion distemper over a coat of alkali resistant primer over two coats of internal grade wall care putty ( total thickness shall not be less than 1.50mm), finished even and smooth complete all as specified and directed. 180 SQUARE METRE
16 16 Preparation of new plastered surfaces of walls and applying two coats of weather-proof exterior emulsion paint over a coat of primer and over two coats of exnternal grade wall care putty ( total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed\n 155 SQUARE METRE
17 17 Complete removal of existing treatment from external surfaces of walls /ceiling and applying two coats of weather-proof exterior emulsion paint over a coat of primer and over two coats of external grade wall care putty ( total thickness shall not be less than 1.50mm), finished even and smooth, complete all as specified and directed\n 210 SQUARE METRE
18 18 Preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc chrome primer, complete all as specified and directed.\n 120 SQUARE METRE
19 19 Preparation of old painted steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint complete all as specified and directed.\n 1000 SQUARE METRE
20 20 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc.(measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed.\n 24 RUNNING METRE
21 21 160mm bore UPVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with and including provision of suitable size of PVC clamps complete all as specified and directed.\n 24 RUNNING METRE
22 22 160mm bore UPVC (SWR) bends/shoe any radius with and including provision of suitable size of PVC clamps complete all as specified and directed.\n 8 EACH
23 23 Plain cement concrete 1:2:4 type B0 12.5mm graded stone aggregate as in benching ,roof kerbs and including necessary formwork as required and including demolition of old concrete complete all as specified and directed. 3 CUBIC METRE
24 24 Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials and making good disturbed surfaces of walls, floors, etc, complete all as specified and directed.\n 493 POINT
25 25 Point wiring complete with 1.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 V grade drawn through and including 20mm dia PVC conduit, medium grade, and conduit accessories, concealed in walls and terminated to and including provision of concealed modular box suitable for logic modular switches, sockets etc., and including logic modular white plates for fixing modular switches, sockets / regulators etc., including 1.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly with brass screws, washers, copper lugs etc., complete all as specified and directed for one light / fan point /bell point controlled by one, one-way switch 5 Amp. \nNOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.\n(ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing 109 POINT
26 26 All as per item No.25 above but for 5 Amps socket on independent board 30 POINT
27 27 All as per item No.25 above but for 5 Amps socket on same board 10 POINT
28 28 Point wiring complete with 2.5 sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor 1100 Volts grade, ISI marked, drawn through in and including 20mm dia rigid PVC conduit medium grade and conduit accessories, concealed in stone / brick masonry walls, roofs, floors etc, by means of saddles and clips etc, including provision of modular metal flush boxes with modular metal frame plate and white cover for housing switches, sockets, regulators etc., including 2.5sq.mm PVC insulated unsheathed multi-stranded FRLS copper conductor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for 3-pin 15/16 Amp socket outlet point on independent board, complete all as specified and directed.\nNOTE: (i) The quoted rate shall deemed to include the cost of metal flush boxes, modular white cover plate, provision of blank plates as per requirement etc.\n(ii) Quoted rate shall also deemed to include cost of making necessary chases in walls for inserting metal boxes and making good the disturbed surfaces to match with existing\n 180 POINT
29 29 Modular Switch single pole 6 Amps, one way, 1 module complete all as specified and directed.\n\n 313 EACH
30 30 Modular Switch single pole 16 Amps, one way, 1 module complete all as specified and directed.\n\n 180 EACH
31 31 Modular Socket 6 Amps multipurpose 2 in 1 ,2/3 combined 2 module complete all as specified and directed.\n\n 40 EACH
32 32 Modular Socket 6/16Amps multipurpose 2 in 1 ,2/3 combined 2 module complete all as specified and directed.\n\n 180 EACH
33 33 Ceiling rose three terminal surface poly carbonated isolated body AC 50 Hz 230V, complete all as specified and directed.\n\n 273 EACH
34 34 Modular step type fan regulator, 2 Module 230Volts ,120 watt complete all as specified and directed.\n\n 20 EACH
35 35 High bay 150W LED light fittings IP 65 protected liminaire robust open type vertical Highbay /Mediumbay LED IP 54 luminaire with high power COB LED as light source of luminous efficiancy not less than 120lm/w complete temp 5700K including fixing to the ceiling using necessary fastener /hook for hanging the lights and connecting with three core 2.5 Sqmm round copper cable from ceiling rose to the connector of the fitting complete all as specified and directed.\n\n 78 EACH
36 36 Security light fitting 20W IP 65 protection 5700K color temp ,made up of die cast alluminium housing with high power LED as lighting source and lens embeded PC lens having complete fixing with GI bracket made out of 40mm bore GI pipe light grade 1.5 Metre long bend to shape and fixed to pole /wall with necessary MS clamps & accessories complete all as specified and directed.\n 25 EACH
37 37 1x20W ,230V surface and wall mounted LED batten single side connection T8 liminaires with one 20Watt LED retrofit T8 polycarbonate tube single side connection and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed.\n 64 EACH
38 38 Recess mounting 36W LED edge-lit luminaire suitable for armstrong /grid ceiling complete for low ceiling application made with CRCA sheet metal with premium white high translucent frosted wide diffuser of size 2'x2' ,luminaire efficacy > 120lm/w provided with surge supressor electronic driver complete with all accessories including electronic driver suitable for the ceiling light connecting with twin core felxible cable complete all as specified and directed.\n 58 EACH
39 39 Sub main wiring complete with 4 runs of single core 6 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 20mm dia and its accessories and connecting terminal ends to DB's including providing 2 runs of single core 6 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed.\nNOTE:- (i) Four runs of 6 sq.mm copper conductor, Two runs of 6.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length.\n(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.\n 35 RUNNING METRE
40 40 Sub main wiring complete with 2 runs of single core 4 sq.mm PVC insulated and unsheathed 1100V grade multistranded FRLS grade copper conductor cable drawn through and including provision of concealed non-metallic rigid PVC conduit 20mm dia and its accessories and connecting terminal ends to DB's including providing 1 run of single core 4 sq.mm PVC insulated unsheathed multistranded FRLS grade copper cable as earth continuity conductor and connecting to common earth dolly, including taking down old sub main wiring of any type and any size and making good disturbed surfaces to match with existing, complete all as specified and directed.\nNOTE:- (i) Two runs of 4 sq.mm copper conductor, One run of 4.0 sq.mm copper earth continuity conductor and one run of PVC conduit shall be measured as one unit length.\n(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.\n 250 RUNNING METRE
41 41 Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one MCB single pole 20Amps 240 volts complete with all accessories etc complete all as specified and directed.\n 24 EACH
42 42 Factory made epoxy powder coated MCB distribution board TP&N 8 way double door (VTPN MCCB DB)MCCB TPN as in comer ,with metal door IP -43 protection ,IK -09 as per IEC -61439-3 fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and 200 Amps copper bus bar ,neutral bar ,standard DIN rail ,earth bar and cable ties for cable management ,top and bottom removable gland plates woth Knockout semi flush to wall and making good distrubed surfaces and touch up with the same finishes complete all as specified and directed.\nNote: All incomimg /out going MCCB/MCBs shall be measured and paid under appropriate item .\n\n 5 EACH
43 43 MCB DB TPN double door 6-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 200 amps rated busbar ,neutral & earthing link bar ,surface mounting and making good distrubed surfaces complete all as specified and directed.\nNote: All MCBs shall be measured and paid under appropriate item .\n 7 EACH
44 44 MCB DB SPN double door 8-way sheet metal enclosure factory made suitable for MCBs 240volts confirming to IEC -61439-3 with 100 amps rated busbar ,neutral & earthing link bar ,surface mounting and making good distrubed surfaces complete all as specified and directed.\nNote: All MCBs shall be measured and paid under appropriate item .\n 2 EACH
45 45 Sheet metal enclosure suitable for MCCB 4pole G-frame including growing with nut bolts ,making connection with existing cables complete with lugs ,glands all as specified and directed.\n\n 24 EACH
46 46 MCCB with rating( min 70% to 100%) of 100 Amps ,415 Volts 4 pole with 16 KA ultimate breaking capacity , G- frame thermal magnetic release with adjustable over load and short circuit release with electronic earth leakage module confirming to IS-139472& IEC-60947-2 & the service short circuit breaking capacity (Ics) shall be equal to ultimate breaking capacity ( Icu) ,MCCB shall be with suitable spreaders and phase barriers for each terminals complete all as specifeid and directed.\n\n\n 29 EACH
47 47 MCB FP 63 Amps, 'C'curve, working on 415V ,50Hz, 10KA breaking capacity including removing of unserviceable MCB complete all as specifeid and directed.\n\n\n\n 7 EACH
48 48 MCB DP 40 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity including removing of unserviceable MCB complete all as specifeid and directed.\n\n\n\n 2 EACH
49 49 MCB SP 6- 32 Amps, 'C'curve, working on 240V ,50Hz, 10KA breaking capacity complete all as specifeid and directed.\n\n\n\n 100 EACH
50 50 Taking down ceiling/exhaust/wall mounted/pedestal fans/ air circulators of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections, removing worn out bearings, capacitor, bushes and over hauling/painting including replacement of minor parts like split pins, nuts, screws, washers etc and other worn out spare parts as required, greasing, reassembling and reconnecting with 3 core new flexible cord from ceiling rose to fan, testing and commission complete all as specified and directed.\n 47 EACH
51 51 Disconnecting and taking down indoor and outdoor units of split AC of any make and capacity upto 2Ton with stabilizer from the existing position ,servicing the indoor and out door unit complete carefully without damage any other parts ,top up of referigerant as per existing type ,gas top up minor and repair and refixing the same after renovation of building complete all as specified and directed.\n 24 EACH JOB
52 52 Earthing complete with GI earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth wire 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 20mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber, 15mm thick RCC cover (1:2:4) mix with 6mm dia nominal reinforcement @ 150mm c/c both ways etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. \nNOTE:-1 Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate.\n 6 EACH SET
53 53 GI earth wire of 4mm dia fixed on walls /floor as earth lead continuity conductor connected to DBs /panels etc complete all as specified and directed.\n\n 50 RUNNING METRE
54 54 LT UG cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor, LT 1100 volts grade, ISI mark as per IS-7098 (Part -1) -1985, cross-sectional area 35 sq.mm 3.50core, laid in trenches / on poles / walls including fixing arrangements (GI saddles with screw) connecting with aluminium lugs ,necessary cable glands , connecting up, testing on completion and commissioning, and including removing old unserviceable cable complete all as specified and directed.\n 660 RUNNING METRE
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail