Repair Maintenance Of Wiring Dbs Sub Main Wiring Fittings And Earthing For Defence Civilian Md Accn At Ashoka Park Pallava Park And Allied Area Under Ge Nd Visakhapatnam
BOQ
| Name of Work: REPAIR / MAINTENANCE OF WIRING, DBs, SUB MAIN WIRING FITTINGS AND EARTHING FOR DEFENCE CIVILIAN MD ACCN AT ASHOKA PARK, PALLAVA PARK AND ALLIED AREA UNDER GE (ND) VISAKHAPATNAM | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | The rates quoted by the tenderer shall deemed to be inclusive for the following provisions in addition to the other conditions specified in the tender documents. No claim whatsoever shall be entertained at a later date on this account:-\n[i] The repairs shall be done by skilled workmen in the relevant field to the entire satisfaction of Engineer-in-Charge. The contractor shall engage sufficient manpower for the entire period so that progress of work shall not be hampered due to non availability of labour at any time.\n[ii] The contractor on getting information through Site order / Works diary regarding the nature of repair to be carried out, he shall immediately respond to the same and make all out efforts to carry out the same on priority within 48 hours. In case of any delay in responding / attending the repairs within 48 hours, the GE may at his absolute discretion impose penalty on the contractor at Rs. 100/- per day per each work ordered upto 05(Five) days and Rs. 200/- per day thereafter till completion of the work in case of delay without valid reasons as decided by GE.\n[iii] Further, the above penalty is applicable even for the multiple locations of work at the same period. It is the responsibility of contractor to make suitable arrangements for attending the repairs simultaneously at all the places.\n[iv] The decision of the GE as to whether a particular repair has been attended or not on a particular day will be final and binding. The above penalty shall be in addition to the provisions made in clause 50 of IAFW-2249 i.e (Compensation for delay in completion of work). | |||
| 2 | 2 | Taking down carefully Copper / Aluminium point wiring(light,fan,socket or power) complete along with fittings such as switches ,Sockets, ceiling rose , lamp holder ,tube light fittings and making good distrubed surfaces on walls etc.\n | 880 | Point | |
| 3 | 3 | M&L for point wiring with 1.5sqmm PVC insulated unsheathed multistranded copper cable of FRLS grade with one run of 1.5sqmm PVC insulated copper cable as earth continuity drawn in and including surface PVC conduit not less than 20mm dia including pressed steel consealed MS box duly covered with 3mm thick hylem sheets for mounting switches/Sockets, accessories such as spacers, saddles, junction boxes for one light / fan point / socket 5 Amp on independent board/ Bell point controlled by one switch.\n | 450 | Point | |
| 4 | 4 | All as per item No.3 above but 5 Amps socket on same board | 30 | Point | |
| 5 | 5 | All as per item No.3 above but with 4 sqmm PVC insulated unsheathed multistranded copper FRLS grade cable with one run of 4sqmm PVC insulated copper cable as earth continuity for power socket on independent board. | 300 | Point | |
| 6 | 6 | All as per item No.3 above but stair case light point controlled by 2 Nos of 2 way switches for stair case wiring | 100 | Point | |
| 7 | 7 | S & F, Switch piano, flush type, single pole, one way, 5 Amps, 230 Volt including taking down old unserviceable switches all as directed. | 700 | Each | |
| 8 | 8 | S & F, Switch piano, flush type, single pole, Two way, 5 Amps, 230 Volt including taking down old unserviceable switches all as directed. | 100 | Each | |
| 9 | 9 | S&F electronic fan regulator as per site requirement to use in wiring socket/ Switch type 300 Watt | 450 | Each | |
| 10 | 10 | S & F Bell AC ,230V Single pole | 100 | Each | |
| 11 | 11 | S & F Bell push ,Flush type , AC 230V Sigle pole | 200 | Each | |
| 12 | 12 | S&F ceiling rose surface bakelite 3 terminals 65X50mm 230V including PVC Box of size 3\"X3\" round type. | 350 | Each | |
| 13 | 13 | S & F Switch socket combination, multipurpose, 3 pin, 5 Amps, flush type with 1.5 sqmm cable | 700 | Each | |
| 14 | 14 | S & F Switch socket combination, multipurpose, 2 in 1, 3 pin, 5/15 Amps, flush type, universal controlled by one switch 15 Amps, 250 Volts, ISI marked complete with 4 sqmm cable all as specified and directed. | 400 | Each | |
| 15 | 15 | Taking down ceiling fan and refixing of after cleaning all as directed. | 700 | Each | |
| 16 | 16 | M & L for removal of existing ceiling fan of any sweep of any make for servicing with replacement of ball bearings, replacement of winding, bushes, capacitors, nuts & bolts etc. and greasing & Painting for the smooth operation and refixing the same as directed \nNote 1 :-The work to be carried out at respective sites in the presence of MES rep.\nNote 2 : Spares such as bearings & capacitors etc, if required shall be measured and paid separately under relevant items. | 800 | Each | |
| 17 | 17 | Supply only bearing suitable for ceiling fan \nMake : SKF or equivalent as approved by GE. | 200 | Each | |
| 18 | 18 | Supply only capacitor 2.5 mfd suitable for ceiling fan | 200 | Each | |
| 19 | 19 | Supply and fixing in replacement of Fan Clamp suitable for 1200mm Ceiling fan | 300 | Each | |
| 20 | 20 | Supply and fixing in replacement of down rod 0.48mtr suitable for 1200mm Ceiling fan | 250 | Each | |
| 21 | 21 | Supply and fixing in replacement of down rod 1.2mtr suitable for 1200mm Ceiling fan | 250 | Each | |
| 22 | 22 | Supply and fix LED tube light fitting 18 W batton type 230 V AC supply all as directed. | 30 | Each | |
| 23 | 23 | Supply and fix LED tube light fitting 9 W batton type 230 V AC supply all as directed. | 25 | Each | |
| 24 | 24 | Taking down existing light fitting of any type and any shape and refixing it in new location complete all as specified and directed. | 220 | Each | |
| 25 | 25 | M&L for painting to ceiling fan, down rod and blanks with synthetic enameled white/brown colour paint including Stencil of MES No complete all as specified and directed | 300 | Job | |
| 26 | 26 | Repairs of exhaust fan/air circulator/Pedestal Fan of any size by opening cleaning and rewinding the motor by suitable gauge of copper winding wire, bearing, and Painting with two coats of synthetic enamel paint over a coat of red oxide primer and refixing with replacement of nut & bolts testing and commissioning complete all as specified and directed. | 150 | Each | |
| 27 | 27 | S & F Building security light LED type 45W on Magazine building wall including GI pipe 40mm dia with clamps \nMake : CG cat part No LSTP-45-CDL or equivalent in bajaj/philips/wipro | 32 | Each | |
| 28 | 28 | S & F Building security light LED type 25W on building wall including GI pipe 25mm dia with clamps \nMake : CG cat part No LSTP-25-CDL or equivalent in bajaj/philips/wipro | 10 | Each | |
| 29 | 29 | Supply and fix batten suitable for LED T8 lamps Make: CG Cat Part No DMLN1LT8-16 or equivalent in bajaj/philips/wipro | 110 | Each | |
| 30 | 30 | S&F PVC box for fixing of electrical KWH meter of any type and any capacity complete all as directed | 100 | Each job | |
| 31 | 31 | Taking down and refixig of electrical KWH meter after rewiring complete all as directed | 35 | Each | |
| 32 | 32 | Taking down old DB's housing MS box of size (0.8mx0.85x0.4m) from the existing location and flush out the existing surfaces with necessary brick works (1:6) and rendering with cement plaster (1:4) and making good surfaces with existing colour complete all as specified and directed. | 16 | Each Job | |
| 33 | 33 | S&F in repairs GI Louvers powder coated suitable for exhaust fan 300mm sweep. \nNote: Quoted rate is deemed to be included for Provision of scaffolding or down lift or any type of supporting arrangement for high rise bldgs upto 9th floor to execute the fixing of Louvers | 20 | Each | |
| 34 | 34 | Supply and fix Vertical DBs 8 way and provision for TPN MCCB 125 Amps 25kA as Incomer.\nNote : MCCB will be measured and paid under relevant item | 10 | Each | |
| 35 | 35 | S & F MCCB 125 Amps 25 KA 4 pole 415 Volts 50 HZ | 10 | Each | |
| 36 | 36 | Supply and fix PVC conduit 25mm dia concealed in wall / roofs/ floors / ceiling exclusive of boxes (junction / Terminal ) but inclusive of all tees, bends, elbows, reduces bell mout tube ends and fixing accessories such as couplers and lock nuts, saddles, pipe hooks etc for drawing coaxial TV cable or Telephone cable etc complete all as specified,\nNote- The PVC Conduit to Concealed in wall through cutting,Chassing,Pining and making good surface where required and poining in cement mortar and making good for same | 60 | RM | |
| 37 | 37 | Cutting chases, pinning in , making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landing , steps, cills, sunshades, shelves, lintels, etc and cutting chasses for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth brick walls complete all as specified and directed. | 60 | RM | |
| 38 | 38 | Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall,ceiling and making good surfaces to match with original status as specified and directed. | 580 | RM | |
| 39 | 39 | M&L for sub main wiring with 2 runs of 2.5 qmm PVC insulated unsheathed copper cable multistand 1100 V of FRLS grade with drawn in Surface PVC conduit not less than 25mm dia and one run of PVC insulated unsheathed of 2.5sqmm as earth continuity conductor drawn in PVC conduit with accessories complete\nNOTE: 2 runs of 2.5 Sqmm, 1 run of 2.5 Sqmm and 1 run of conduit will be measured as one unit i.e RM | 150 | RM | |
| 40 | 40 | M&L for sub main wiring with 2 runs of 4 sqmm PVC insulated unseheathed copper cable multistrand 1100 V of FRLS grade with drawn in Surface PVC conduit not less than 20mm dia and one run of PVC insulated unsheathed of 4sqmm as earth continuity conductor drawn in PVC conduit with accessories complete\nNOTE: 2 runs of 4 Sqmm, 1 run of 4Sqmm and 1 run of conduit will be measured as one unit i.e RM | 210 | RM | |
| 41 | 41 | M&L sub main wiring with 2 runs of 6 sqmm PVC insulated unsheathed copper cable multistrand 1100 V of FRLS grade with drawn in Surface PVC conduit not less than 20mm dia and one run of PVC insulated unsheathed of 6sqmm as earth continuity conductor drawn in PVC conduit with accessories complete\nNOTE: 2 runs of 6 Sqmm, 1 run of 6 Sqmm and 1 run of conduit will be measured as one unit i.e RM | 220 | RM | |
| 42 | 42 | Supply & Replace MCB DB 4 way TPN with 200 A rated bus bar, 415 Volts, Double door complete all as directed. | 8 | Each | |
| 43 | 43 | Supply & Replace MCB DB 12 way SPN with 200 A rated bus bar, 240 Volts, Double door complete. | 30 | Each | |
| 44 | 44 | Supply & Replace 100 Amps MCB 415 Volt, four pole, 50 Hz, AC supply, | 25 | Each | |
| 45 | 45 | Supply & fix RCB 30 mA SPN in place of defective old MCB's with 40 Amps capacity all as directed.\n | 60 | Each | |
| 46 | 46 | Supply & Replace MCB SP 6 to 40 Amps 240 Volts | 450 | Each | |
| 47 | 47 | Supply only flexible hose 1 / 2\" white colour for fixing of tube light fittings | 50 | Each | |
| 48 | 48 | M & L for PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) to repair disturbed surface for fixing of DBs. | 6 | Cum | |
| 49 | 49 | M & L for Brick work with subclass 'B' bricks straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 | 6 | Cum | |
| 50 | 50 | M & L for rendering 15 mm thick on fair faces of brick work or concrete in CM 1:6 & finshing even & smooth without using extra cement | 10 | Sqm | |
| 51 | 51 | Supply and fix switch Piano, flush type, single pole, one way, 5 Amp | 150 | Each | |
| 52 | 52 | Supply and fix in repairs switch piano, flush type, single pole, one way, 15 Amp | 20 | Each | |
| 53 | 53 | Supply and fix in repairs 5 pin 5 Amp switch socket combination | 120 | Each | |
| 54 | 54 | Supply and fix in repairs 5 pin 15 Amp switch socket combination | 90 | Each | |
| 55 | 55 | Supply and fix in repairs electronic fan regulator step type suitable for 1200mm ceiling fan | 150 | Each | |
| 56 | 56 | Supply and fix in repairs Ceiling rose, 3 Terminals PVC/polycarbonate, isolated body | 120 | Each | |
| 57 | 57 | Supply and fix in repairs RCB DP 32 A, 100 mA | 45 | Each | |
| 58 | 58 | Supply & Replace sheet metal enclosure single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB 20 Amps capacity. | 35 | Each | |
| 59 | 59 | M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 M below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as specified and directed and all as shown in electrical plate No.3 of SSR part 1. | 20 | Each | |
| 60 | 60 | Material and labour for earthing complete with galvanised steel earth plate elctrode 600x 600 x 6.3 mm thick buried in ground not less than 2.25 mts deep below ground level with top edge of the plate not less than 1.5 meters below normal ground connected GI earth strip of size 32 x 6 mm fixed by means of bolts,nuts ,check nuts, and washers of galvanised iron GI pipe 25 mm dia perforated and top edge including necessary excavation earth work etc and earh pit size 300 x 300 x 300 mm with PCC type C1 1:3:6 RCC cover salab with type B1, 1:2:3 as per SSR plate No.3 and testing on completion. | 1 | Each |
AI Tender Summary
Tender Timeline
Feb 28, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedMar 20, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 25, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender