| 1 | 1 | Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section 503 of specifications. | BI01010001010000000000000515BI0100001124 | | |
|---|
| 2 | 1.01 | (i) @ 0.30 kg per sqm (dry&hungry bituminous surface/granular surfaces treated with primer | BI01010001010000000000000515BI0100001125 | 47437.5 | Sqm |
|---|
| 3 | 1.02 | (ii) @ 0.25 kg per sqm (normal bituminous surfaces) | BI01010001010000000000000515BI0100001126 | 41250 | Sqm |
|---|
| 4 | 2 | Dense Graded Bituminous Macadam Providing and laying dense bituminous macadam using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler,transporting the hot mix to work site , laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 505 of specification complete in all .respects (a) Using Batch Mix Plnt of appropriate capacity and Paver finisher Hydraustatic with Sensor | BI01010001010000000000000515BI0100001127 | | |
|---|
| 5 | 2.01 | (ii) for GradingII(19 mm nominal size) | BI01010001010000000000000515BI0100001128 | 2371.88 | Cum |
|---|
| 6 | 3 | Bituminous Concrete Providing and laying bituminous concrete using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory andtandem rollers to achieve the desired compaction as per clause 507 of specification in all respect. (a )Using Batch Mix Plnt of appropriate capacity and Paver finisher Hydraustatic with Sensor control | BI01010001010000000000000515BI0100001129 | | |
|---|
| 7 | 3.01 | (iv) for Grading-II ( 30-45 mm thickness ) with 60/70 bitumen(VG-30) | BI01010001010000000000000515BI0100001130 | 1237.5 | Cum |
|---|
| 8 | 4 | Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100 kN static weight to meet requirement as per relevant clause of 400 | BI01010001010000000000000515BI0100001131 | | |
|---|
| 9 | 4.01 | B Hard Shoulders (CBR value >12) | BI01010001010000000000000515BI0100001132 | 2025 | Cum |
|---|
| 10 | 5 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes all complete as per clause 803 of specifications. | BI01010001010000000000000515BI0100001133 | 389.5 | Sqm |
|---|
| 11 | 6 | Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2010 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide clause 801.3.3 fixed over Aluminium composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminium with overall thickness of 4mm and aluminium skin of thickness 0.3 on both side, the ACM shall conform to Table 800-1 of specification and High Intensity Micro Prismatck Grade Sheeting shall conform to Table 800-3 of specification. The printing on the high intensity grade sheeting shall conform to Clause 801.3.7 with water based latex optimized transparent ink as specified by the sheeting manufacturer, supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to ground by means of properly designed foundation with M15 grade concrete 450x450x600mm The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. | BI01010001010000000000000515BI0100001134 | | |
|---|
| 12 | 6.01 | i) 90 cm equilateral triangle | BI01010001010000000000000515BI0100001135 | 30 | Each |
|---|
| 13 | 6.02 | ii) 60 cm equilateral triangle | BI01010001010000000000000515BI0100001136 | 30 | Each |
|---|
| 14 | 6.03 | iii) 60 cm circular | BI01010001010000000000000515BI0100001137 | 25 | Each |
|---|
| 15 | 6.04 | iv) 80cm x 60cm rectangular | BI01010001010000000000000515BI0100001138 | 30 | Each |
|---|
| 16 | 6.05 | i) 60cm x 45cm rectangular | BI01010001010000000000000515BI0100001139 | 30 | Each |
|---|
| 17 | 7 | Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc | BI01010001010000000000000515BI0100001140 | | |
|---|
| 18 | 7.01 | (ii) Ordinary Kilometer stone (Precast) | BI01010001010000000000000515BI0100001141 | 12 | Each |
|---|
| 19 | 7.02 | iii) Hectometer stone (Precast) | BI01010001010000000000000515BI0100001142 | 52 | Each |
|---|