Construction Of New Govt . Degree College At Qazigund Kulgam Kashmir Phase-1 ( Winter Zone )
Tender Value
8.16 Crore
Estimated cost
Bid Submission
21 Mar 2020
0 days left
EMD
16.33 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Qazigund → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of New Govt . Degree College At Qazigund Kulgam Kashmir Phase-1 ( Winter Zone )
BOQ
| Name of Work: Construction of New Govt. Degree college at Qazigund Kulgam Kashmir phase-1 (winter zone). Estimated Cost Rs. 816.49 Lacs | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | EXCAVATION | |||
| 2 | 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | 2480 | Cum | |
| 3 | 3 | SOILING | |||
| 4 | 4 | Porviding and laying of stone soiling below raft foundation, with stone size of 100-250 mm to be hand packed with interstices (if any) to be filled with sand duly to be consolidated and compacted.(Rate on LMR Basis) | 315 | Cum | |
| 5 | 5 | MUDMATE | |||
| 6 | 6 | 4.1 Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) grade excludingthe cost of centering and shuttering - All work up to plinth level. | 175 | Cum | |
| 7 | 7 | CONTROLLED CEMENT CONCRETE | |||
| 8 | 8 | Reinforced cement concrete(M20) work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement . | |||
| 9 | 9 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm\nnominal size) | 2120 | Cum | |
| 10 | 10 | FILLING | |||
| 11 | 11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each\ndeposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 2200 | Cum | |
| 12 | 12 | Supply, filling with river sand /nallah muck in 20cm layers including watering, compacting and dressing under flooring in ground floor.(Rate on LMR Basis) | 1100 | Cum | |
| 13 | 13 | FORMWORK | |||
| 14 | 14 | Form work of steel plates not less than 3.0mm thick M.S. sheets of specified size stiffened with suitable structral frame work true to plane or kit ply plates of not less than 12mm thickness of specifed sizes stiffened with suitable timber frame work prop height upto desired height in pile caps ,plinth beams,all types of suspended floors ,sofits of slabs,sloping areas, sides and soffits of beams ribs ,columns posts, pedestals, ornamental projections upto desired height and thickness complete including its removal for all RCC works from plinth to roof level.(Rate on LMR Basis) .\n | 8950 | Sqm | |
| 15 | 15 | REINFORCING STEEL | |||
| 16 | 16 | Steel reinforcement of high strength deformed steel bars of Fe 415 grade (conforming to IS 1786-1985) for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete, from foundation to roof.(pile reinforcement included).\n | 320 | Ton | |
| 17 | 17 | BRICK MASONRY\n | |||
| 18 | 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in 1:6 cement mortar (1 cement: 6 coarse sand) up to desired height in each floor from plinth to roof level including any recession or arches as per architectural drawings.\n | 595 | Cum | |
| 19 | 19 | WOOD WORK | |||
| 20 | 20 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) of first class deodar wood. \n | 26 | Cum | |
| 21 | 21 | Providing and fixing 35mm thick panelled or panelled and glazed shutters for doors, ,of first class kail wood including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. | 175 | Sqm | |
| 22 | 22 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors of first class kail wood (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters of 35mm thick. | 95 | Sqm | |
| 23 | 23 | Providing and fixing 35mm glazed shutters for, windows and clerestory windows of ,first class kail wood using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. | 230 | Sqm | |
| 24 | 24 | Providing and fixing 35mm thick wire gauge shutters of first class kail wood using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws.\n | 230 | Sqm | |
| 25 | 25 | P/F of 40mm thick 300mm wide eaves boarding of first class kail wood including erection,fixing,and applying of primer coat ,complete as per specifications including cost necessary frame work for complete support.(Rate on LMR Basis) | 345 | Rm | |
| 26 | 26 | P/F of 12mm thick 600mm wide soffit of T&G imported wood paneling including erection,fixing,and applying of pu polishing coat ,complete as per specifications including jam work(1.5\"x3\" of budloo wood) underneath complete. (Rate on LMR Basis) | 207 | Sqm | |
| 27 | 27 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). | 1560 | No's | |
| 28 | 28 | STRUCTURAL STEEL | |||
| 29 | 29 | supplying and erecting welded built-up/rolled section of M.S/S.S grill of required pattern for ground floor windows as per design including priming coat.(Rate on LMR Basis) | 1150 | Kg | |
| 30 | 30 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels ,plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). | 75 | kg | |
| 31 | 31 | FLOOR FINISHES | |||
| 32 | 32 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. | 700 | Sqm | |
| 33 | 33 | Kota stone slab 25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab,including rubbing and polishing complete with base of cement mortar 1 : 4 (1cement : 4 coarse sand) :\n | 1350 | Sqm | |
| 34 | 34 | Cement concrete flooring of 50 mm thick in 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement complete, with 20 mm nominal size stone aggregate. | 2800 | Sqm | |
| 35 | 35 | Extra for providing and fixing of glass strips in joints of cement concrete flooring: 40mm wide & 4mm thick. | 4000 | Rm | |
| 36 | 36 | CEILING & WALL FINISHES | |||
| 37 | 37 | plaster work | |||
| 38 | 38 | Inner surfaces: i):15mm thick cement plaster in 1:6 cement mortar , in walls using coarse sand.. | 6200 | Sqm | |
| 39 | 39 | ii):12 mm thick cement plaster in 1:4 cement mortar using coarse sand, in ceiling with curing. | 3100 | Sqm | |
| 40 | 40 | External surfaces:15 mm thick cement plaster in 1:6 cement mortar using coarse sand,on exterior wall surfaces with curing. | 1800 | Sqm | |
| 41 | 41 | Providing and applying wall putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.\n | 9400 | Sqm | |
| 42 | 42 | Distempering with dry distemper of approved brand and manufacture (two or more coats) of required shade on new work, over and including water thinnable priming coat to give an even shade. | 9400 | Sqm | |
| 43 | 43 | Applying external plasterd wall surfaces with one coat of water thinnable cement primer of approved brand and manufacture on wall surface : | 1800 | Sqm | |
| 44 | 44 | Finishing External walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) | 1800 | Sqm | |
| 45 | 45 | providing and applying of primer coat over new wood and wood based surfaces with white primer of specified brand, including cost of sand papering and cleaning the surface. | 1950 | Sqm | |
| 46 | 46 | Painting new wood / wood based surfaces with two or more coats of synthetic Enamel of specified shade and brand to an even shade excluding priming and preparation of surfaces but including cost of sand papering and cleaning. | 1950 | Sqm | |
| 47 | 47 | PLINTH PROTECTION | |||
| 48 | 48 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.. | 340 | sqm | |
| 49 | 49 | CARRIAGE OF MATERIALS | |||
| 50 | 50 | Cement upto 25 kms | 21900.2 | per bag | |
| 51 | 51 | steel(structural /reinforcining) upto 30 kms | 1446.56 | tonne | |
| 52 | 52 | Carriage of sand upto 20 kms | 1414.35 | Cum | |
| 53 | 53 | Carriage of coarse aggregattes of nominal size (40mm/20mm/10mm) upto 20kms | 2348.1 | Cum | |
| 54 | 54 | Providing and fixing Orissa pattern white vitreous china W.C. pan of size 580x440 mm with integral type foot rests.( Indian type W.C Pan) with 100 mm PVC P or Strap, 10 litre low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures, complete including cutting and making good the walls and floors wherever required.\n | 19 | No's | |
| 55 | 55 | Providing and fixing wash basin with C. I./M.S. brackets, 15mm C.P. brass pillar taps, , including painting of fittings and brackets, cutting and making good the walls wherever required: \na) White Vitreous Chinawash basin size 660x450 mm with a pair of 15 mm C.P brass pillar tap with elbow operated levers \n | 35 | No's | |
| 56 | 56 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mmand 340x410x265 mm sizes respectively with automatic Flushing cistern with C.I./M.S.brackets standard size of G. I. flush pipe and C.P. brass spreaders with brass unions and G.I.clamps complete, including painting of fittings and brackets, cutting and making good the wafls and floors wherever required. | 13 | No's | |
| 57 | 57 | One urinal basin with 5 litre P.V.C white automatic flushing cistern of approved quality | |||
| 58 | 58 | P/F stainless steel A ISI 304(18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40mm inc. painting of fittings and brackets cutting and making good the walls whereever required (610 x 460 bowl) depth 200m inc cost and carriage of all materials | 2 | No's | |
| 59 | 59 | Providing/Fixing C.P Brass bib cocks of approved Quality and weighing not less than 810 Gms 15 mm nominal bore JAQUAR or Parko make.\n | 20 | No's | |
| 60 | 60 | Providing/Fixing 15 mm C.P brass close hole wall mixer /Basin/Sink Mixer/Swing Cock of approved quality PARKO/CERA make etc and weighing not less than 1.970 Kgs. | 35 | No's | |
| 61 | 61 | Providing/ Fixing 15 mm C.P. brass angle valve of approved make conforming to ISI: 893. 15 mm nominal bore of JAQUAR or PARKO make.\n | 67 | No's | |
| 62 | 62 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | 12 | No's | |
| 63 | 63 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C. P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete | 12 | No's | |
| 64 | 64 | Providing / fixing PTMT 215 mm long and 200 mm wide towel rail of approved brand with all necessary fittings & fixtures complete | 12 | No's | |
| 65 | 65 | Providing / fixing of soap dish / holder, towel ring, towel hanger, toothpaste / brush holder etc. inc. cost and carriage.\n | |||
| 66 | 66 | a)C.P. brass Soap Dish | 24 | No's | |
| 67 | 67 | b)C.P. Brass Towel Ring | 12 | No's | |
| 68 | 68 | c)C.P. Brass toilet paper holder | 20 | No's | |
| 69 | 69 | Providing and fixing C.P. Brass nipples 15mm size (150mm long) inc. cost and carriage of all materials. | 85 | No's | |
| 70 | 70 | Providing and fixing of 40mm dia PVC waste pipe for sink or wash basin inc. PVC waste fittings complete. | 24 | No's | |
| 71 | 71 | Providing and fixing PVC floor trap inc. cost and carriage of all materials complete job | 36 | No's | |
| 72 | 72 | Providing and fixing PVC P Trap 100mm dia incl. cost and carriage of all materials complete job | 36 | No's | |
| 73 | 73 | Providing / fixing water geyser of standard quality ISI marked of approved brand and manufacture with all necessary fittings and fixtures complete as approved by site Engineer: \n | |||
| 74 | 74 | a) 50 litre capacity | 1 | No's | |
| 75 | 75 | Providing and fixing 100 mm C.P. gratings inc. cost and carriage of all materials complete. | 50 | No's | |
| 76 | 76 | Providing / Fixing of PVC pipes type B prince quality complete with PVC fittings and clamps, including tees, branches, collars, bends etc of prince make or equvilant.\n | |||
| 77 | 77 | c) 100 mm dia. | 300 | Rm | |
| 78 | 78 | d)150mm dia | 220 | Rm | |
| 79 | 79 | Providing and fixing PVC fittings and accessories inc. cost and carriage, all complete : | |||
| 80 | 80 | i)Door Tee 100mm | 20 | No's | |
| 81 | 81 | j)Plain Bend 100mm | 20 | No's | |
| 82 | 82 | k)Reducer 100 x 150mm | 20 | No's | |
| 83 | 83 | l)Plain Tee 100mm dia | 20 | No's | |
| 84 | 84 | m)Reducer Tee 100 x 150mm | 20 | No's | |
| 85 | 85 | n)Door Tee 150mm dia | 20 | No's | |
| 86 | 86 | o)90d Plain bend 150mm dia | 40 | No's | |
| 87 | 87 | p)Plain Tee 150mm dia | 20 | No's | |
| 88 | 88 | q)45d plain bend ,100mm | 20 | No's | |
| 89 | 89 | r)45d plain bend ,150mm dia | 20 | No's | |
| 90 | 90 | Providing/ Fixing of 75 mm dia vent pipe with cowel, complete job | 20 | No's | |
| 91 | 91 | Providing and fixing G.l. pipes complete with G.l. fittings and clamps, including cutting and making good the walls etc.: Class-C heavy duty make suriya prakash\na) 15 mm dia. nominal bore | 200 | Rm | |
| 92 | 92 | b) 20 mm dia nominal bore | 100 | Rm | |
| 93 | 93 | c) 25 mm dia nominal bore. | 550 | Rm | |
| 94 | 94 | d) 40 mm dia nominal bore | 170 | Rm | |
| 95 | 95 | Providing/Fixing gun metal gate valve with C.I.wheel of approved quality (Screwed end )\n\n | |||
| 96 | 96 | b)25 mm dia | 5 | No's | |
| 97 | 97 | c) 40mm dia nominal bore. | 5 | No's | |
| 98 | 98 | Providing and placing on terrace , polyethylene water storage tank lSI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes including necessary fittings [Sintex, Electroplate, Star, Lotus or equivalent having valid lSI license]. \n | 16000 | Litres | |
| 99 | 99 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) R.C.C. top slab with 1 :1.5:3 mix ( 1 cement : 1.5coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design incld all carraiage of material involved | 30 | No's | |
| 100 | 100 | Providing and fixing of water pump of (2.5-H.P inc. Starter incl. all fittings and Cost involved of Crompton Greaves or Kirloskar make | 1 | No's | |
| 101 | 101 | Earth work in excavation in foundation by manual or mechanical means in trenches for foundation not exceeding the like not exceeding 10 Sqm on plan all kinds of soil incld disposal of excavated earth lifted beyond the Municipal limits or as directed by Engineer in charge \n\n | 262.43 | Cum | |
| 102 | 102 | Providing /Laying dry stone soling hand packed tightly including all carriage and cost of material complete.\nSeptic Tank: 2 x 14' 0\" x 12' 0\" x 6\" = 168Cft\n Qty. =168.00cft or 4.76 cum or 5cum(say)\n\n | 5 | Cum | |
| 103 | 103 | Providing and laying in position cement concrete of specified grade excluding the cost cantering & shuttering all work upto plinth level in 1:4:8 mix ( 1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size (Crushed) incld all carriage & cost involved. \n | 5 | Cum | |
| 104 | 104 | Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand . : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate (Crushed). incld all carriage of material involved.\n\n | 31.22 | Sqm | |
| 105 | 105 | Brick work with common burnt clay F.P.S ( non –modular) bricks of class designation 75 in foundation and plinth in cement mortar 1:6 ( 1 cement :6 coarse sand) incld .all carriage and cost involved.\n | 30.19 | Cum | |
| 106 | 106 | Dry random rubble masonry with hard stones in foundation and plinth using quarry stone incld all cost and carriage. \n\n\n | 65.68 | Cum | |
| 107 | 107 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of cantering. Shuttering, finishing and reinforcement-All work up-to plinth level. 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size) incld all carriage of material involved.\n\n\n\n | 10.34 | Cum | |
| 108 | 108 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. incld all carriage of material involved.\n | 1241 | Kg | |
| 109 | 109 | Centring and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. incld all carriage of material involved.\nSlabs:\n S.T:\n2 x 14' 0'' x 12' 0\" = 336.00 Sft\nSoakage Pit;2 x ?/4 x (8')² = 100.48 Sft\n Qty = 436.48 Sft or 40.56 Sqm\n | 40.56 | Sqm | |
| 110 | 110 | 15 mm Cement plaster on the rough side of single or half brick wall of mix: 1:4 mix incld all carriage complete \n\n | 78.06 | Sqm | |
| 111 | 111 | Providing and fixing of whit vitreous china pedestals for wash basins of approved brand completely recessed at the back for the reception of pipes and fittings including cost and carriage | 35 | No's | |
| 112 | 112 | Providing and fixing C.P. Brass nipples 15mm size (100mm long) inc. cost and carriage of all materials. | 90 | No's | |
| 113 | 113 | Providing and fixing of C.P. waste of approved brand 32mm dia incl. cost and carriage | 35 | No's | |
| 114 | 114 | Providing / Fixing of PVC pipes type B prince quality complete with PVC fittings and clamps, including tees, branches, collars, bends etc of prince make or equvilant.\n | |||
| 115 | 115 | a)50mm dia | 90 | Rm | |
| 116 | 116 | b)75mm dia | 100 | Rm | |
| 117 | 117 | Providing and fixing PVC fittings and accessories inc. cost and carriage, all complete : | |||
| 118 | 118 | a)Door Tee 75mm dia | 10 | No's | |
| 119 | 119 | b)90d Plain Bend ,75mm dia | 6 | No's | |
| 120 | 120 | c)Collar 75mm | 5 | No's | |
| 121 | 121 | d)Plain Tee 75mm dia | 10 | No's | |
| 122 | 122 | e)Reducer 75-100mm | 10 | No's | |
| 123 | 123 | f)Door Bend 75mm dia | 10 | No's | |
| 124 | 124 | g)Floor Trap 75mm | 10 | No's | |
| 125 | 125 | h)45d plain bend ,75mm | 5 | No's | |
| 126 | 126 | i) Floor Trap 100mm Dia | 12 | No's | |
| 127 | 127 | Providing and fixing of 32mm dia PVC waste pipe for sink or wash basin inc. PVC waste fittings complete. | 37 | No's | |
| 128 | 128 | Providing and fixing G.I fittings and accessories incl. cost and carriage | |||
| 129 | 129 | a)20mm Union (in G.I pipe incl. cutting , and threading the pipe and making long screws etc. complete) | 42 | No's | |
| 130 | 130 | b)Reducer 15-20mm | 38 | No's | |
| 131 | 131 | Providing/Fixing gun metal gate valve with Brass wheel of approved quality (Screwed end )\n\n | |||
| 132 | 132 | a)15mm Dia | 5 | No's | |
| 133 | 133 | b)20mm dia | 5 | No's | |
| 134 | 134 | c) 25 mm dia nominal bore. | 3 | No's | |
| 135 | 135 | d)40mm dia | 5 | No's | |
| 136 | 136 | Providing and fixing of water connectors ISI marked 18\" long incl cost and carriage : | 15 | No's | |
| 137 | 137 | Providing and fixing of Tank nipples 40mm dia of standard length ISI Marked incl. cost and carriage all complete | 10 | No's | |
| 138 | 138 | Providing and fixing of Geyser Bolts of standard size and length for Geysers /wash basins . | 80 | No's | |
| 139 | 139 | Supply and laying of 2nd class sand/Dust from approved source free from dirt or other unwanted material incl. cost and carriage all complete\n | 10 | Cum | |
| 140 | 140 | Providing and laying water proofing treatment in Basement/Walls of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :\n(a) First layer of slurry of cement@ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/sqm.\nb)Laying Second layer of Fibre glass cloth when the ist layer is still green.Overlaps of joints of fibre cloth should not be less than 10Cms.\n(b)Third layer of 1.5mm thcikness consisiting of slurry of cement @ 1.289 kg/sqm\nmixed with water proofing cement compound@ 0.67Kg/Sqm, mixed with water proofing of cement compound @0.67 Kg/Sqm/Coarse sand @1.289Kg/Sqm. . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The entite treatment will be taken upto 30cm on parapit and levied into groove all around.The water proofing compound used be Sica - Reintite. The rate includes prepartation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry.\nQty. = 12 x2x2x( 6' 6'' + 6' 6\") x 6'6\" + \n 2 x 12 x 6'6\" x 6'6\" \n =5070 sft\nD/d Doors : 12 x 2 x 2'6\" x 7'0\" = (-)420 Sft\n Qty. = 4650 Sft or 432.16 Sqm | 75 | Sqm | |
| 141 | 141 | Edge(D) moulding 6\" wide in corners WCs/ Bathrooms etc of cement concrete for sealing of joints to make it water proof incl. cost and carraige of materials all complete\n | 336 | Rft | |
| 142 | 142 | Making out of Holes in Brick walls of size upto (9\" x 9\" x 14\").The rate shall include cutting, dressing and refiiling in all respects.All complete | 80 | No's | |
| 143 | 143 | Making out of Holes in R.C.C walls of size upto (2'0\" x 2'0\" x 9\") .The rate shall include cutting, dressing and refiiling in all respects all complete | 60 | No's | |
| 144 | 144 | Making of Brick Plateform for Orrisa pattern water closets of size upto 3'0\" x 3'0\" x 1'2\" all complete | 12 | No's | |
| 145 | 145 | Insulation of G.I. pipes(All Dia) exposed directly to environment by using suitable foam to prevent it from bursting. | 400 | Rm | |
| 146 | 146 | Internal Electrification Work | |||
| 147 | 147 | SUB HEAD-1 WIRING | |||
| 148 | 148 | Wiring for switch controlled primary light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface/concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications( Group C) | 325 | Point | |
| 149 | 149 | Wiring for switch controlled emergency light points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications and as required | 75 | Point | |
| 150 | 150 | Wiring for ceiling fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 6 Amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box with space for mounting an electronic fan regulator and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications. | 115 | Point | |
| 151 | 151 | Wiring for exhaust fan points with 1.5 sq mm FRLS PVC insulated stranded copper conductor 1100 volt grade wires in PVC surface / concealed conduit including cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting and including the cost of providing and fixing a 3 pin 6 Amp shuttered socket outlet and 6 amp 240 volt grid plate mounted modular switch with modular cover plate in zinc chromate passivated MS box and including the cost of running 1.5 sqmm PVC insulated stranded copper conductor wire for loop earthing complete as per specifications.Conduit carrying non-essential wiring shall not have essential or UPS wiring. Wiring for essential and UPS Providing,transportation will have thier own conduit system. No mixing of wiring is allowed. | 20 | Point | |
| 152 | 152 | Providing,transportation & fixing following suitable size modular GI box on surface or in recessas, painting etc.required. | |||
| 153 | 153 | 2 Module | 60 | Each | |
| 154 | 154 | 4 Module | 155 | Each | |
| 155 | 155 | 6 Module | 75 | Each | |
| 156 | 156 | Providing and fixing of following size modular cover plate on existing modular metal boxes etc. as required. | |||
| 157 | 157 | 1 or 2 Module | 60 | Each | |
| 158 | 158 | 4 Module | 155 | Each | |
| 159 | 159 | 6 Module | 75 | Each | |
| 160 | 160 | Providing,transportation and fixing of 6 Amp 3/5 pin modular socket-on the existing modular plate & switch box excluding modular plate as required. | 145 | Each | |
| 161 | 161 | Providing,transportation and fixing of 16 Amp modular switch on the existing modular plate & switch box excluding modular plate as required. | 220 | Each | |
| 162 | 162 | Providing,transportation and fixing of 16 Amp modular socket on the existing modular plate & switch box excluding modular plate as required. | 155 | Each | |
| 163 | 163 | Providing and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 70 | Each | |
| 164 | 164 | Providing and fixing stepped type 2M-electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. | 115 | Each | |
| 165 | 165 | Providing,transportation and fixing ISI marked medium class PVC conduit on surface/recessed along with accessories including the cost of providing saddles etc for surface conduiting and/or cost of cutting and filling chases for recessed conduiting complete as per specifications as below and as required for sub circuits/ voice/ data/ TV system. | |||
| 166 | 166 | 25 mm dia | 7242 | Meter | |
| 167 | 167 | 40 mm dia | 200 | Meter | |
| 168 | 168 | Providing,transportation and fixing of RJ-11 modular socket on the existing modular plate & switch box excluding modular plate as required for telephone system | 40 | Each | |
| 169 | 169 | Providing and drawing 2Pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing recessed PVC conduit as required. | 950 | Meter | |
| 170 | 170 | Providing,transportation and fixing of the following sheet steel clad wall / recess mounting 10 Pair telephone tag block of IDC type constructed from 16 SWG sheet steel, finished with red oxide coating & two coats of paint, with hinged gasketted door and complete with adequately rated and sized telephone terminal block to receive incoming and outgoing wires. | 7 | Each | |
| 171 | 171 | Providing,transportation and fixing of RJ-45 modular socket on the existing modular plate & switch box excluding modular plate as required for networking system | 45 | Each | |
| 172 | 172 | Providing,transportation fixing, laying, testing and commissioning of 4-pair Cat 6e LAN cable in existing concealed / surface conduits in partition wall, complete as requiredTelephone system and computer network will have separate conduit. No mixing of telephone and power wiring is allowed. | 1500 | Meter | |
| 173 | 173 | SUB HEAD III-SUB MAINS AND CABLES | |||
| 174 | 174 | Wiring for circuits/submains with FRLS PVC insulated stranded copper conductor 1100 volt grade wires in surface/concealed conduit and including FR PVC insulated copper wire for earthing and making suitable end connections complete as required and as below. | |||
| 175 | 175 | 2 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire. | 2895 | Meter | |
| 176 | 176 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. | 3500 | Meter | |
| 177 | 177 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. | 500 | Meter | |
| 178 | 178 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire. | 600 | Meter | |
| 179 | 179 | 2 X 16 sq. mm + 1 X 16 sq. mm earth wire. | 400 | Meter | |
| 180 | 180 | SUB HEAD IV-DISTRIBUTION SYSTEM | |||
| 181 | 181 | Providing,transportation, Providing and fixing following way,horizontal type three pole/single pole and neutral,sheet steel, MCB distribution board, 415/240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator).Non-essential, Emergency and Power will have separate sub main boards. No mixing of wiring is allowed. | |||
| 182 | 182 | 6 way TPN double door | 8 | Each | |
| 183 | 183 | 8 way TPN double door | 2 | Each | |
| 184 | 184 | 12 way SPN double door | 9 | Each | |
| 185 | 185 | 16 way SPN double door | 7 | Each | |
| 186 | 186 | Providing and fixing 5 amps to 32 amps rating, 240 volts SP MCB 10kA, \"C\" curve, miniature circuit breaker suitable in the existing MCB DB complete with connections, testing and commissioning etc. | 210 | Each | |
| 187 | 187 | Providing and fixing following rating, double/four pole, 240/415 volts, DP/TPN MCB 10kA \"C\" curve in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 188 | 188 | 32 amp | 7 | Each | |
| 189 | 189 | 63 amps | 7 | Each | |
| 190 | 190 | 100 amps TPN | 12 | Each | |
| 191 | 191 | Providing and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. | |||
| 192 | 192 | 25 amps | 5 | Each | |
| 193 | 193 | 32-40 amps | 5 | Each | |
| 194 | 194 | Providing and fixing single pole blanking plate in the existing MCB DB complete etc. as required. | 25 | Each | |
| 195 | 195 | Providing,transportation , providing and commissioning of following size cable in pipe/ Tray/ clamped to wall with suitable clamps saddles and fixing bolts. | |||
| 196 | 196 | 3.5 core 240 Sq mm AL XLPE | 210 | Metre | |
| 197 | 197 | 3.5 core 120 Sq mm AL XLPE | 210 | Metre | |
| 198 | 198 | Laying in ground including the cost digging and back filling with sand and brick protection as required The costs shall include for all cables to be provided with a 1D gap and shall be properly clamped with cable clamps and ties. Identification tags shall be provided for all cables and route markers for cables in ground. | |||
| 199 | 199 | 3.5 core 240 Sq mm AL XLPE | 210 | Metre | |
| 200 | 200 | 3.5 core 120 Sq mm AL XLPE | 210 | Metre | |
| 201 | 201 | Providing,transportation and making end termination of the following size XLPE insulated cables 1100 Volt grade including cost of crimping tinned copper heavy duty lugs, brass compression glands, insulation tape and all requisite material for completion of joints. | |||
| 202 | 202 | 3.5 core 240 Sq mm AL XLPE | 8 | nos | |
| 203 | 203 | 3.5 core 150 Sq mm AL XLPE | 8 | nos | |
| 204 | 204 | Providing,transportation and fixing of 6in dia heavy PVC pipe complete as required. | 180 | Metre | |
| 205 | 205 | Providing,transportation ,providing and fixing of 4in dia heavy PVC pipe complete as required . | 180 | Metre | |
| 206 | 206 | Providing,transportation and fixing of 50W LED slim flood light. | 12 | nos | |
| 207 | 207 | Providing,transportation,providing and fixing of fan box | 115 | Each | |
| 208 | 208 | Providing,transportation,providing and fixing of fan plates big size | 115 | Each | |
| 209 | 209 | SUB HEAD V-FIXTURES AND FITTING | |||
| 210 | 210 | Supply, transportation and fixing of 1x1 18W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of min100 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. | 355 | Each | |
| 211 | 211 | Supply, transportation and fixing of 2x2 36W surface downlighter with a nominal system lumen output of 2050 lumens and a minimum system efficacy of 115 lm/W complete as required The luminaire shall have a rated system lifetime of 50,000 burning hours at L70 with LG7 The luminaire shall meet IP20 rating with THD<10%. The luminaire housing should made of aluminium and the luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. | 60 | Each | |
| 212 | 212 | SITC of ISI marked 5star energy saving 1200 mm sweep ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required. | 115 | Each | |
| 213 | 213 | SITC of exhaust fan 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. | 20 | Each | |
| 214 | 214 | Sample of all type of light fixtures / fans / exhaust fans / other fittings shall be approved from architect / site engineer & the sample of each approved fixture / fitting shall be kept & maintained at site. | |||
| 215 | 215 | SUB HEAD VI-Cable Tray | |||
| 216 | 216 | Providing,transportation fixing and installing 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, inconvenient sections, including bolts & nuts, painting suspenders etc as required. | 10 | Meter | |
| 217 | 217 | SUB HEAD VI-EARTHING | |||
| 218 | 218 | Providing,transportation & Installation of earth pit comprising of 75 mm Cu pipe filled with crystalline conductive mixture with copper strip of size 40mm x 6mm of length 2 mtrs with eco friendly backfill compound 50 Kgs etc as required conforming to BIS standards having brick masonary chamber with hinged cover. (General Earthing for Each Panel) | 2 | Each | |
| 219 | 219 | (25 x4) mm GI Strip through PVC sleeve (Electrical Earthing) (From Electrical Earthing Pit to Electrical Earthing Busbar) | 275 | Metre | |
| 220 | 220 | Providing and fixing of lightning arrestor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85mm dia 3 mm thick copper base plate including holes etc. complete job as required. | 2 | Each | |
| 221 | 221 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For Horizontal & Vertical run) | 160 | Metre | |
| 222 | 222 | Providing,transportation ing and fixing 20 amps, 240 volts, SPN industrial type, socket outlet. | 6 | Each | |
| 223 | 223 | Design, manufacture, supplying fixing in position, testing and commissioning of the following front operated cubicle type, front access, dead back, steel enclosed free standing, dust and vermin proof, switchboard with with hinged and lockable doors complete with interconnections\n | 36 | cft | |
| 224 | 224 | 630 Amps TPN MCCB | 2 | nos | |
| 225 | 225 | 250 Amps TPN MCCB | 1 | nos | |
| 226 | 226 | 100 Amp DP MCB | 15 | nos | |
| 227 | 227 | 125 Amp TPN MCB | 15 | nos | |
| 228 | 228 | 63 Amp FP Change over Switch | 1 | no. | |
| 229 | 229 | Cast resin current transformers | 3 | nos | |
| 230 | 230 | Amp & Volt Meter | 2 | nos | |
| 231 | 231 | White phase indicating lamps | 3 | nos | |
| 232 | 232 | Supply and fixing of iron stands for panels | 37 | Kgs | |
| 233 | 233 | Supply & Installation of earth pit as required | 2 | Each | |
| 234 | 234 | Supply and fixing of GI strip | 10 | rms | |
| 235 | 235 | supply and fixing of spreaders for solid connections of cables with 630Amp MCCB's | 2 | nos | |
| 236 | 236 | supply and fixing of spreaders for solid connections of cables with 250 Amp MCCB's | 1 | nos | |
| 237 | 237 | External Sub-Station & allied works | |||
| 238 | 238 | Supply, installation, testing and commissioning of 250 KVA Sub Station (11/0.433) 3 phase copper wound outdoor type transformer oil immersed ONAN cooled/dry cooled complete with all fittings Make:AE/Electric Field/ABB Complete \nSITC of Sub station as per JKPDD Standards (Complete job) | 1 | nos | |
| 239 | 239 | Supply, installation, testing and commissioningof 11 kV line on 9 Mt. ST poles with ACSR Rabbit conductor with 52 Mt. span as per JKPDD standards ( Complete job) | 1.25 | Km. |
AI Tender Summary
Tender Timeline
Feb 29, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedMar 21, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMar 24, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender