Construction Of Peb Sewing Unit And Ancillary Facilities ( Only Civil , Electrical , Mechanical And Phe Work Of Peb Sewing Unit And Ancillary Facilities ), DUMKA-Jharkhand

Rural Development Department has published Construction Of Peb Sewing Unit And Ancillary Facilities ( Only Civil , Electrical , Mechanical And Phe Work Of Peb Sewing Unit And Ancillary Facilities ). Submission Date for this Tender is 04-03-2020. PEB Tenders in DUMKA Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

23807083
Construction Of Peb Sewing Unit And Ancillary Facilities ( Only Civil , Electrical , Mechanical And Phe Work Of Peb Sewing Unit And Ancillary Facilities )
Open Tender
Indian
Jharkhand
DUMKA
04-03-2020

Tender Details

Construction Of Peb Sewing Unit And Ancillary Facilities ( Only Civil , Electrical , Mechanical And Phe Work Of Peb Sewing Unit And Ancillary Facilities )

Key Value

Document Fees
INR 10000 /-
EMD
INR 198100.0 /-
Tender Value
INR 99.02 Lakhs /-

BOQ Items

Name of Work: Construction of PEB Sewing Unit and Ancillary Facilities (Only Civil , Electrical, Mechanical & PHE Work of PEB Sewing unit and Ancillary Facilities).
Sl. No. Item Description Item Code / Make Quantity Units
1 1 EARTHWORK: Cutting of Trees along with its branches their removal away from work site and stacking \na) Girth above 0.5 m but upto 0.75 m BI01010001010000000000000515BI0100001111 5 Each
2 2 Earth work in stripping by hydraulic machinery in grade A&B type of soil. beyond 0.5 km upto 1 km BI01010001010000000000000515BI0100001112 75 Cum
3 3 Earth work in stripping by hydraulic machinery in grade A&B type of soil. beyond 1 km upto 2 km BI01010001010000000000000515BI0100001113 7.5 Cum
4 4 Earthwork in excavation in foundation trenches in ordinary soil (Wide classification of soil item - A) and disposal of excavated earth BI01010001010000000000000515BI0100001114 185.33 Cum
5 5 Extra for earthwork in hard soil as per specification and direction of E/I (vide classificatioNosf soil item _B) BI01010001010000000000000515BI0100001115 74.13 Cum
6 6 Filling in foundation trenches and plinth in layers Nost exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed BI01010001010000000000000515BI0100001116 117.15 Cum
7 7 Excavating, supplying and Filling of local earth (including royalty) BI01010001010000000000000515BI0100001117 39.05 Cum
8 8 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. BI01010001010000000000000515BI0100001118 125 Cum
9 9 Supplying chemical emulsion in sealed containers including delivery as specified. Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL\nanti-termite treatment (excluding the cost of chemical emulsion) : BI01010001010000000000000515BI0100001119 150 Liter
10 10 Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration BI01010001010000000000000515BI0100001120 150 Metere
11 11 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm Nosminal size) over 75mm bed of dry brick ballast 40mm Nosminal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. BI01010001010000000000000515BI0100001121 138.75 Sqm
12 12 Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm Nosminal size) BI01010001010000000000000515BI0100001122 42.55 Sqm
13 13 P.CC & R.C.C WORK P.C.C . M-100 with Nosminal mix of (1:3:6) in foundation with approved quality of jhama metal and down well graded and local river sand (washed and screened( - iii ------do---- BI01010001010000000000000515BI0100001123 102.78 Cum
14 14 Providing R.C.C. M - 200 with Nosminal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 \nRCC M-200 with nominal mix of (1:1.5:3) In Foundation BI01010001010000000000000515BI0100001124 49.84 Cum
15 15 RCC M-200 with nominal mix of (1:1.5:3) 25 mm in Damp proof course BI01010001010000000000000515BI0100001125 42.55 Sqm
16 16 Providing 50 mm precast RCC m-200 with Nosminal mix of (1:1.5:3) jali with approved quality BI01010001010000000000000515BI0100001126 43.2 Sqm
17 17 Providing Tor steel reinforcement of 8mm,10mm, 12mm & 16 mm. 8,10 mm BI01010001010000000000000515BI0100001127 3 MT
18 18 Providing Tor steel reinforcement of 20mm, 28mm & 32 mm. dia bars as per approved design and drawing 12/ 16 mm BI01010001010000000000000515BI0100001128 6 MT
19 19 Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I BI01010001010000000000000515BI0100001129 1241.21 Sqm
20 20 Providing Random rubble masonry in super structure BI01010001010000000000000515BI0100001130 24.975 Cum
21 21 FLOORING and WALL TILING WORKS Providing and laying 25mm. Thick kotah stone slab flooring of approved size, texture and colour over 19mm.thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) \n (i) 600x600mm size BI01010001010000000000000515BI0100001131 1231.21 Sqm
22 22 Providing and laying 25mm.thick kotah stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12mm.thick cement mortar (1:3) and joined with grey cement slurry BI01010001010000000000000515BI0100001132 21.6 Sqm
23 23 Providing and laying 30mm thick White / Yellow sand stone BI01010001010000000000000515BI0100001133 29.4 Sqm
24 24 Providing and laying 30mm thick Red sand stone BI01010001010000000000000515BI0100001134 44.1 Sqm
25 25 Providing and laying Cool Roof Tiles- 300 x 300 BI01010001010000000000000515BI0100001135 73.5 Sqm
26 26 ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions BI01010001010000000000000515BI0100001136 476.42 Kg
27 27 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings BI01010001010000000000000515BI0100001137 346.56 Kg
28 28 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. With float glass panes of 5 mm thickness BI01010001010000000000000515BI0100001138 171.808 Sqm
29 29 FLOOR SPRING BI01010001010000000000000515BI0100001139 28 Each
30 30 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality BI01010001010000000000000515BI0100001140 680.6 metre
31 31 Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. BI01010001010000000000000515BI0100001141 10 Each
32 32 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. BI01010001010000000000000515BI0100001142 10 Each
33 33 STEEL WORKS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 – part 1 and M.S. top cover of required thickness for rolling shutters. BI01010001010000000000000515BI0100001143 36 Sqm
34 34 STEEL WORK (M S GRILL) Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing BI01010001010000000000000515BI0100001144 480 Kg
35 35 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube BI01010001010000000000000515BI0100001145 137.5 Kg
36 36 HORTICULTURE WORKS Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately)) BI01010001010000000000000515BI0100001146 27 Nos
37 37 Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) In rows 7.5 cm apart in either direction BI01010001010000000000000515BI0100001147 50 Nos
38 38 Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm) BI01010001010000000000000515BI0100001148 60 Nos
39 39 Maintenance of Lawns or Turfing of Slopes (Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc) BI01010001010000000000000515BI0100001149 60 Nos
40 40 a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart) BI01010001010000000000000515BI0100001150 200 Nos
41 41 b)Maintenance of Hedge for one year BI01010001010000000000000515BI0100001151 100 Nos
42 42 Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year) BI01010001010000000000000515BI0100001152 25 Nos
43 43 Providing and displaying of cephortia Palm plant, having ht. 1.20 m. to 1.50m. with 8-10 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. BI01010001010000000000000515BI0100001153 50 Nos
44 44 LUMPSUM SOFTSCAPE BI01010001010000000000000515BI0100001154 1 Nos
45 45 Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. BI01010001010000000000000515BI0100001155 5 qtl
46 46 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality\n25 mm dia (Average) half cut bamboo placed vertically and fixed together\nwith three numbers horizontal running members of hollock wood in scantling\nof section 50X25 mm, fixed with nails and G.I wire on existing support\ncomplete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001156 12.5 sqm
47 47 CARRIAGE Sand - 10Km BI01010001010000000000000515BI0100001157 80.78 Cum
48 48 S.Chips - 22 Km BI01010001010000000000000515BI0100001158 1.79 Cum
49 49 S.Metal - 22km BI01010001010000000000000515BI0100001159 96.61 Cum
50 50 PHE WORKS \nEarth work in excavation (As per I.S. 3114/1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineerin-Charge. \n(a) For classification of Soil item - A BI01010001010000000000000515BI0100001160 0.72 Cum
51 51 (b) For classification of Soil item - B BI01010001010000000000000515BI0100001161 1.44 Cum
52 52 Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineerin-Charge. (For classification for Soil item - A & B) BI01010001010000000000000515BI0100001162 3.24 Cum
53 53 Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. BI01010001010000000000000515BI0100001163 3.24 Cum
54 54 EXTERNAL WATER SUPPLY Supplying labour and tools for fixing G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketted joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. (Pipe with socket to be supplied\ndepartmentally free of cost).\n(iii) 25 mm dia nominalbore G. I. pipe BI01010001010000000000000515BI0100001164 20 Meter
55 55 (iv) 32 mm dia nominalbore G. I. pipe BI01010001010000000000000515BI0100001165 20 Meter
56 56 Supplying and fixing of G.M. ferrule of approved make in existing C.I. main including drilling and taping C.I. main all complete as per specification and direction of Engineer-in-Charge.\n\n(iii)22 mm and 25 mm dia ferrule weight not less than 900 gms BI01010001010000000000000515BI0100001166 1 Nos
57 57 Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I. BI01010001010000000000000515BI0100001167 1 Nos
58 58 Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. \n(d) 32mm dia and weight not less than 700gms. BI01010001010000000000000515BI0100001168 1 Nos
59 59 Supplying materials and labour for construction of 600x600x90mm stop cock chamber of brick masonry with 125 mm thick work of designation 75B in cement mortar (1:6) with 12mm thick cement plaster in C.M. (1:6) on inside only having 50 mm thick R.C.C. cover having 12 mm dia lifting rings, 2 nos. stop cock chamber will rest over 80mm thick P.C.C. (1:3:6) over one brick flat soling, including cost of earthwork, all complete job, as per approved design, specification and direction of E/I. BI01010001010000000000000515BI0100001169 3 Nos
60 60 INTERNAL WATER SUPPLY SYSTEM \n Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. \n15 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001170 30 Meter
61 61 20 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001171 45 Meter
62 62 25 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001172 10 Meter
63 63 32 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001173 5 Meter
64 64 40 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001174 5 Meter
65 65 External work Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.20 mm nominal outer dia Pipes\n40 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001175 2 Meter
66 66 50 mm nominal outer dia Pipes BI01010001010000000000000515BI0100001176 2 Meter
67 67 62.50 mm nominal inner dia Pipes BI01010001010000000000000515BI0100001177 2 Meter
68 68 Providing and fixing gun metal gate valve with C.I. wheel of approved\nquality (screwed end) :\n32 mm nominal bore BI01010001010000000000000515BI0100001178 2 Nos
69 69 40 mm nominal bore BI01010001010000000000000515BI0100001179 2 Nos
70 70 50 mm nominal bore BI01010001010000000000000515BI0100001180 2 Nos
71 71 65 mm nominal bore BI01010001010000000000000515BI0100001181 2 Nos
72 72 Providing and fixing brass bib cock of approved quality 20 mm nominal bore BI01010001010000000000000515BI0100001182 3 Nos
73 73 Providing and fixing brass stop cock of approved quality\n20 mm nominal bore BI01010001010000000000000515BI0100001183 6 Nos
74 74 EXTERNAL SEWERAGE Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. BI01010001010000000000000515BI0100001184 20 Cum
75 75 Earthwork in back filling the trench after laying different types and sizes of R.C.C. spun pipes with earth removed during excavation within initiallead and lift as per specification and direction of E/I BI01010001010000000000000515BI0100001185 20 Cum
76 76 Extra for earthwork in all kinds of soil foreach additional lift of 1M. or part there of over the intial lift of 1.5M. as per specification and direction of E/I. BI01010001010000000000000515BI0100001186 5 Cum
77 77 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry 'brick honey comb shaft with bricks and S.W. drain pipe 100 mm 'diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001187 2 each
78 78 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:\n100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001188 10 each
79 79 150 x 100 mm size P type BI01010001010000000000000515BI0100001189 10 each
80 80 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001190 6 Nos
81 81 Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001191 5 Nos
82 82 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 455x610 mm and 45 cm deep for single pipe lineWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001192 3 Nos
83 83 Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 BI01010001010000000000000515BI0100001193 5 Nos.
84 84 BORE WELL ,WTP & STP WORKS \nWATER TANK & TERRACE LEVEL WORKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Circular tank BI01010001010000000000000515BI0100001194 6000 Per Ltr
85 85 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in charge,beyond 90 metre & upto 150 metre depth below ground level. \n300 mm dia BI01010001010000000000000515BI0100001195 10 Meter
86 86 Rocky strata including Boulders BI01010001010000000000000515BI0100001196 10 Meter
87 87 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs,\nconforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia BI01010001010000000000000515BI0100001197 20 Meter
88 88 Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. BI01010001010000000000000515BI0100001198 10 Cum
89 89 Providing and fixing suitable size threaded mild steel cap or spot\nwelded plate to the top of bore well housing/ casing pipe, removable\nas per requirement, all complete for borewell of:150 mm nominal size dia BI01010001010000000000000515BI0100001199 1 Nos
90 90 ELECTRICAL \nWIRING SYSTEM Point wiring in PVC conduit, with modular type switch : \nWiring for light point/fan point/exhaust fan point/call bell point with 1.5sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, switch plate, suitable size GI box etc as required complete. \nGroup C BI01010001010000000000000515BI0100001200 150 Point
91 91 Power plug wiring in PVC conduit (2x4sqmm) \nWiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1no. 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required. BI01010001010000000000000515BI0100001201 150 Metre
92 92 Circuit main wiring in PVC conduit : \nWiring for circuit/submain wiring along with earth wire with the following sizes PVC insulated copper conductor, single core cable in surface /recessed PVC conduit as required. \n2 x 1.5sqmm + 1x1.5sqmm earth wire BI01010001010000000000000515BI0100001202 75 Metre
93 93 2 x 4.0sqmm + 1x4.0sqmm earth wire BI01010001010000000000000515BI0100001203 75 Metre
94 94 S/E PVC conduit \nSupplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. \n20mm BI01010001010000000000000515BI0100001204 50 Metre
95 95 25mm BI01010001010000000000000515BI0100001205 50 Metre
96 96 32mm BI01010001010000000000000515BI0100001206 25 Metre
97 97 S/F Modular type switch / socket \nSupplying and fixing following modular type switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc as required.\n5/6amps, one way switch BI01010001010000000000000515BI0100001207 20 Each
98 98 5/6amps, two way switch BI01010001010000000000000515BI0100001208 3 Each
99 99 15/16amps, one way switch BI01010001010000000000000515BI0100001209 3 Each
100 100 5/6amps, 3 pin socket outlet BI01010001010000000000000515BI0100001210 15 Each
101 101 15/16amps, six pin socket outlet BI01010001010000000000000515BI0100001211 15 Each
102 102 Telephone socket outlet BI01010001010000000000000515BI0100001212 5 Each
103 103 TV socket outlet BI01010001010000000000000515BI0100001213 3 Each
104 104 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. \nS/F Modular type blanking plate BI01010001010000000000000515BI0100001214 10 Each
105 105 Supplying and fixing blanking plate on the existing modular plate and switch box but excluding modular plate etc as required. BI01010001010000000000000515BI0100001215 50 Each
106 106 S/F Modular boxes, base and cover plate \nSupplying and fixing following size modular GI box along with modular base and cover plate for modular switches in recess etc as required.\n 1 or 2 module BI01010001010000000000000515BI0100001216 5 Each
107 107 4 or 5 module BI01010001010000000000000515BI0100001217 100 Each
108 108 6 module BI01010001010000000000000515BI0100001218 10 Each
109 109 8/9 module BI01010001010000000000000515BI0100001219 15 Each
110 110 12 module BI01010001010000000000000515BI0100001220 3 Each
111 111 ITC fluorescent fitting directly on the surface \nInstallation, testing and commissioning of prewired fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc directly on ceiling/wall including connection with 1.5sqmm FR PVC insulated copper conductor. BI01010001010000000000000515BI0100001221 50 Each
112 112 ITC fluorescent fitting with downrods \nInstallation, testing and commissioning of prewired fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc including supplying and fixing ball and socket arrangement 2no. down rods of 20mm dia steel BI01010001010000000000000515BI0100001222 50 Each
113 113 ITC ceiling fan \nInstallation, testing and commissioning of ceiling fan, including wiring the downrods of standard length (upto 30cm) with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. BI01010001010000000000000515BI0100001223 10 Each
114 114 Numbering of fan/fittings \nNumbering of ceiling fan/exhaust fan/fluorescent fitting as required. BI01010001010000000000000515BI0100001224 5 Each
115 115 ITC exhaust fan upto 450mm sweep \nInstallation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good of the damage, connection, testing, commissioning etc as required. BI01010001010000000000000515BI0100001225 5 Each
116 116 Fixing louvers shutters for exhaust fan \nExtra for fixing the louvers shutters complete with frame for a exhaust fan of all sizes BI01010001010000000000000515BI0100001226 5 Each
117 117 SWITCH GEARS AND DBs \nS/F SP MCB DB \nSupplying and fixing following way single pole neutral, sheet steel MCB distribution board, 240V on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, DIN bar, detachable gland plate, interconnections, phosphatized and powder painetd including earthing etc as required,(But without MCB/RCCB/Isolator)\n12 way double door BI01010001010000000000000515BI0100001227 2 Each
118 118 16 way double door BI01010001010000000000000515BI0100001228 1 Each
119 119 S/F Vertical type TP MCBDB \nSupplying and fixing the following way, three pole and neutral, sheet, MCB distribution board, 415V, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, DIN bar, detachable gland plate, interconnections, phosphatized and powder painetd including earthing etc as required,(But without MCB/RCCB/Isolator)\n4way (8+12) Double door, vertical type BI01010001010000000000000515BI0100001229 2 Each
120 120 8way (8+24) Double door, vertical type BI01010001010000000000000515BI0100001230 2 Each
121 121 12way (8+36) Double door, vertical type BI01010001010000000000000515BI0100001231 2 Each
122 122 S/F B series SP MCB \nSupplying and fixing 6A to 32A rating, 240V, B series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCBDB complete with connections, testing and commissioning etc as required. 6/32amps, single pole, B series BI01010001010000000000000515BI0100001232 10 Each
123 123 S/F C series SP MCB \nSupplying and fixing following rating, 240V, C series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCBDB complete with connections, testing and commissioning etc as required.\n6/32amps, Single pole BI01010001010000000000000515BI0100001233 10 Each
124 124 6/32amps, SPN BI01010001010000000000000515BI0100001234 1 Each
125 125 6/32amps, TPN BI01010001010000000000000515BI0100001235 3 Each
126 126 50/63amps, TPN BI01010001010000000000000515BI0100001236 2 Each
127 127 S/F SPMCB blanking plate \nSupplying and fixing single pole blanking plate in existing MCBDB complete as required. BI01010001010000000000000515BI0100001237 10 Each
128 128 S/F four pole MCB isolator \nSupplying and fixing following rating four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.\n40 amps BI01010001010000000000000515BI0100001238 25 Each
129 129 63 amps BI01010001010000000000000515BI0100001239 25 Each
130 130 80/100 amps BI01010001010000000000000515BI0100001240 10 Each
131 131 125 amps BI01010001010000000000000515BI0100001241 10 Each
132 132 Supplying and fixing following rating double pole, 240V, residual current circuit breaker(RCCB) having a sensitivity current upto 300mA in the existing MCBDB complete with connections, testing and commissioning as required.\n16/25 amps BI01010001010000000000000515BI0100001242 1 Each
133 133 40 amps BI01010001010000000000000515BI0100001243 12 Each
134 134 63 amps BI01010001010000000000000515BI0100001244 10 Each
135 135 S/F TPN RCCB \nSupplying and fixing following rating TP&N, 415V, residual current circuit breaker(RCCB) having a sensitivity current upto 300mA in the existing MCBDB complete with connections, testing and commissioning as required.\n40 amps BI01010001010000000000000515BI0100001245 4 Each
136 136 63 amps BI01010001010000000000000515BI0100001246 3 Each
137 137 S/F 20amps SPN MCB industrial socket outlet \nSupplying and fixing 20amps, 240V, SPN industrial type, socket outlet with 2 poleand earth, metal enclosed plug top along with 20amps C series SP MCB in a sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required. BI01010001010000000000000515BI0100001247 25 Each
138 138 P/F danger notice plate \nProviding and fixing M.V danger notice plate of 200mm x 150mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. BI01010001010000000000000515BI0100001248 4 Each
139 139 P/F HT danger notice plate \nProviding and fixing M.V danger notice plate of 250mm x 200mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. BI01010001010000000000000515BI0100001249 2 Each
140 140 EARTHING GI Earth pipe electrode \nEarthing with GI earth pipe 4.5m long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. BI01010001010000000000000515BI0100001250 25 Set
141 141 Copper earth plate electrode \nEarthing with copper plate 600mm x 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc(but without charcoal and salt as required.) BI01010001010000000000000515BI0100001251 5 Set
142 142 Salt / coke for plate earth electrode \nExtra for using salt and coke for GI or copper plate earth as required. BI01010001010000000000000515BI0100001252 4 Set
143 143 P/F 25mmx5mm copper earth strip in surface/recess \nProviding and fixing 25mmx5mm copper earth strip on surface or in recess for connections etc as required. BI01010001010000000000000515BI0100001253 85 metre
144 144 P/F 25mmx5mm GI earth strip in surface/recess \nProviding and fixing 25mmx5mm GI earth strip on surface or in recess for connections etc as required. BI01010001010000000000000515BI0100001254 150 metre
145 145 P/F 6SWG GI loop earthing wire in surface/recess \nProviding and fixing 6SWG GI wire on surface or in recess for connections etc as required. BI01010001010000000000000515BI0100001255 100 metre
146 146 LV/MV CABLE LAYING (WITH SAND AND PROTECTIVE COVERING)\nMV cable laying upto 25sqmm in ground: \nLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of size not exceeding 25sqmm direct in ground excavation, sand cushioning, protective covering and refilling the trench etc as required. BI01010001010000000000000515BI0100001256 50 Metre
147 147 MV cable laying upto 400sqmm in ground: \nLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of size exceeding 120sqmm and not exceeding 400sqmm direct in ground excavation, sand cushioning, protective covering and refilling the trench etc as required. BI01010001010000000000000515BI0100001257 25 Metre
148 148 HV CABLE LAYING\n11kV cable laying upto 120sqmm in ground: \nLaying of one number PVC insulated PVC sheathed /XLPE power cable of grade exceeding 1.1kV but not exceeding 11kV of size not exceeding 120sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. BI01010001010000000000000515BI0100001258 5 Metre
149 149 11kV cable laying upto 400sqmm in ground: \nLaying of one number PVC insulated PVC sheathed /XLPE power cable of grade exceeding 1.1kV but not exceeding 11kV, of sizeexceeding 120sqmm and not exceeding 400sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. BI01010001010000000000000515BI0100001259 5 Metre
150 150 Hard rock excavation \nExcavation of trench in hard rock not exceeding 1.5m in width, and lift upto 1.5 m, including getting out the excavated soil and disposal of excavated soil as directed with in a lead of 50m. BI01010001010000000000000515BI0100001260 5 Cum
151 151 ROUTE MARKERS \nSupplying and making cable route marker with cement concrete 1:2:4 of size 60cm x 60cm at the bottom and 50cm x 50cm at the top with a thickness of 10cm including inscription duly engraved as required. BI01010001010000000000000515BI0100001261 5 Each
152 152 SUPPLY OF MATERIALS PVC INSULATED COPPER CONDUCTOR \n4 pair, 0.5sqmm copper conductor, FR PVC insulated, unarmoured telephone cable BI01010001010000000000000515BI0100001262 50 Metre
153 153 Co-axial TV cable RG6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with FR PVC sheath. BI01010001010000000000000515BI0100001263 50 Metre
154 154 PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100volts \n6sqmm, 2 core BI01010001010000000000000515BI0100001264 50 Metre
155 155 10sqmm, 2 core BI01010001010000000000000515BI0100001265 25 Meter
156 156 10sqmm, 4 core BI01010001010000000000000515BI0100001266 50 Metre
157 157 16sqmm, 4 core BI01010001010000000000000515BI0100001267 12 Metre
158 158 25sqmm, 3.5 core BI01010001010000000000000515BI0100001268 75 Metre
159 159 35sqmm, 3.5 core BI01010001010000000000000515BI0100001269 25 Metre
160 160 50sqmm, 3.5 core BI01010001010000000000000515BI0100001270 50 Metre
161 161 185sqmm, 3.5 core BI01010001010000000000000515BI0100001271 25 Metre
162 162 240sqmm, 3.5 core BI01010001010000000000000515BI0100001272 50 Metre
163 163 Excavation and refilling (as per SOR 2018) BI01010001010000000000000515BI0100001273 250 Metre
164 164 CEILING FAN / WALL FAN / EXHAUST FANS \nCeiling fan 1200mm BI01010001010000000000000515BI0100001274 2 Each
165 165 15" (380mm) metal exhaust fan BI01010001010000000000000515BI0100001275 20 Each
166 166 LED FITTINGS \nrecess mounting LED round down light (15/16W) BI01010001010000000000000515BI0100001276 3 Each
167 167 Recess mounting LED TUBE light (18/20W) BI01010001010000000000000515BI0100001277 40 Each
168 168 Recess mounting LED Panel light 2' x 2' (36W) BI01010001010000000000000515BI0100001278 5 Each
169 169 LED Street light (30W) BI01010001010000000000000515BI0100001279 20 Each
170 170 LED Flood light (120W) BI01010001010000000000000515BI0100001280 1 Each
171 171 Non-Schedule Item. BI01010001010000000000000515BI0100001281
172 172 MISCELLANEOUS WORKS \nDrinking water kiosks Frame will be MS and Panel will be of ACP. Kiosk will be designed in the way that Raw water storage tank, RO, Chiller and pure water storage, tank can be fixed inside it. Acquires very less space. Best suitable for all Urban & Rural areas Minimum space required- 4 feet* 4 feet* 10 feet. Ground water recharge system (Optional) Solar panel can be enabled (optional) BI01010001010000000000000515BI0100001282 4 Nos
173 173 Supplying and fixing GI angle iron brackets, hangers, supports for maintenance as per detail drawing for supporting sewerage, rain water and water supply pipes in shafts with suitable MS clamps, bolts, nuts and washers, fixed on shaft walls etc. complete. BI01010001010000000000000515BI0100001283 200 kgs
174 174 Supplying materials and constructing rain water harvesting recharge pits of 1.2 m dia and 3 m depth with RCC Precast rings including excavation and graded aggregate packing around the rings 300 mm thick with all lead and lift etc., complete as directred by the Engineer in charge BI01010001010000000000000515BI0100001284 4 Nos
175 175 Supplying, fixing and testing PVC soil, waste and vent pipes (SWR) confirming to IS13592 :1992, type B with rubber ring (confirming IS:5382) joint inclusive of all necessary specials like bends, tees, offsets, door ends, junctions, cowls, etc., laid velow ground, complete. The quoted rate should include necessary PCC supports.'a) 110mm dia BI01010001010000000000000515BI0100001285 20 Meter
176 176 INTERNAL SEWAGE SYSTEM \nSupplying, fixing and testing PVC soil, waste and vent pipes (SWR) confirming to IS13592 :1992, type B with rubber ring (confirming IS:5382) joint inclusive of all necessary specials like bends, tees, offsets, door ends, junctions, cowls, etc., laid under floor/fixed on walls, and in pipe shafts etc., complete. The quoted rate should include necessary MS angle supports, grip bolts and clamps etc.,a) 110mm dia BI01010001010000000000000515BI0100001286 25 Meter
177 177 b) 75 mm dia BI01010001010000000000000515BI0100001287 25 Meter
178 178 c) 50 mm dia - 10kg/sqcm-wash basin/Sink BI01010001010000000000000515BI0100001288 10 Meter
179 179 d) 40mm dia- 10kg/sqcm-wash basin BI01010001010000000000000515BI0100001289 25 Meter
180 180 e) 63mm dia ( type A) BI01010001010000000000000515BI0100001290 10 Meter
181 181 Supply and fixing SWR PVC Plain/multi floor traps of `P' or `S' type with SS grating (heavy quality hopper type with frame) and 75mm outlet with necessary water proofing after fixing. ( FOR URINALS- Supplying, fixing and testing of 75mm PVC P trap for urinals with fabricating boss connection for inlet pipe, with SS frame and grating 75mm dia. outlet, fixed below slab suspended to the ceiling, including connection pipe, necessary support etc. complete0 (Heavy duty type) BI01010001010000000000000515BI0100001291 6 Nos
182 182 Supplying, fixing and testing PVC rain water collection kurra with leaf trap grating made out of UPVC with flange complete. (Terrace rain water )a) 110mm dia- Side entry BI01010001010000000000000515BI0100001292 2 Nos
183 183 Supply, Installation & Commissioning of Sewage \nTreatment Plant of Capacity 2 KLD.\nSystem- SBR type BI01010001010000000000000515BI0100001293 1 Set
184 184 Supply, lowering & installation of RCC readymade humepipe septic tank at suitable location including earth work excvation in all types of soil, necessary pcc bedding as directed including sewerline connections at inlet & outlet, Inspection Chambers etc., complete as per standard design & as directed. \n50 User Capacity BI01010001010000000000000515BI0100001294 1 Set
185 185 Providing, fixing and commissioning suitable complete Pumping system consisting of horizontal /vertical multistage centrifugal pump having stainless steel (SS 304) impellers, shaft (SS-316) and housing, with single mechanical seal and pressurised tank of 100 liters capacity, complete with all standard accessories.\nNo. of Pumps : 2 (1 working + 1 stand by) \nCapacity : 100lpm of Each Pump \nHead : 20 m \n \n BI01010001010000000000000515BI0100001295 1 Set
186 186 Supply, Installation & Commissioning of Water Treatment Plant of Capacity 3.5 KLD.\nSystem Consists :- \nFeed Pumps 2 nos, Pressure sand filter, Activated Carbon Filter, Softner, UV Sterlizer, complete frontal piping & Valves, Control Panel with necessary etc.\nNos of Streams-1\nProduct Flow - 0.5 m3/ hr BI01010001010000000000000515BI0100001296 1 Set
187 187 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse\nsand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :\n0.91 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement\n: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :\nWith common burnt clay F.P.S. (non modular)\nbricks of class designation 7.5 BI01010001010000000000000515BI0100001297 4 Nos
188 188 LT PANEL BOARDS \nSupply, installation, testing and commissioning of M.V.Distribution Boards suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be free standing, floor mounting, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi tier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. The painting shall be done in conformity with IS code. \nAdequate size cable alley shall be provided all round the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Flexible cable links are not acceptable. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. The copper earth strip of adequate size in 2runs shall run throught out the perimeter of the bottom of the panel. The panel shall be fabricated only after the approval of fabrication drawings by the consultant.\nAll MCB used for lighting loads shall be B curve, motor loads shall be C curve and used for computer or any thyristor loads shall be D curve. \nAll potential free contacts for Breakers " ON" "OFF" " TRIP" will be wired with required connector suitable for BMS cable termination. BI01010001010000000000000515BI0100001298 1 Set
189 189 APFC (75kVAr) \nAPFC panel comprises :\nOne (1) - Incomer feeder having : \nOne (1) - 200A, TPN, 25kA, MCCB. The MCCB shall be microprocessor based with trip free feature with ON, OFF and TRIP indications, with 2NO+2NC auxiliary contacts, terminal shrouds, sliding type front operation kit with shunt trip release, overload (adjustable), short circuit and earth fault releases. \nOne (1) - 0-200A analog Ammeter with selector switch, Cl1.o, flush mounting.\nThree (3) - 200/5A, 5VA, Cl 1.0, CTs\nOne (1)- 6 stage automatic power factor control relay as required. \nOne (1) lot indicating lamps and push buttons for ON / OFF control / indication of the capacitors and three phase indicating lamps.\nOutgoing feeders BI01010001010000000000000515BI0100001299 1 Set
190 190 LT CABLES END TERMINATIONS AND CABLE TRAYS. \nProviding & Install cable terminations for the above cables including double compression type chrome plated brass glands and lugs(crimping type), gland earthing, PVC taping as required and all accessories complete.\n6sqmm, 2 core, A2XWY BI01010001010000000000000515BI0100001300 100 Set
191 191 10sqmm, 2 core A2XWY BI01010001010000000000000515BI0100001301 4 Set
192 192 10sqmm, 4 core A2XWY BI01010001010000000000000515BI0100001302 10 Set
193 193 16sqmm, 4 core A2XWY BI01010001010000000000000515BI0100001303 4 Set
194 194 25sqmm, 3.5 core A2XFY BI01010001010000000000000515BI0100001304 10 Set
195 195 35sqmm, 3.5 core A2XFY BI01010001010000000000000515BI0100001305 12 Set
196 196 50sqmm, 3.5 core A2XFY BI01010001010000000000000515BI0100001306 4 Set
197 197 185sqmm, 3.5 core A2XFY BI01010001010000000000000515BI0100001307 2 Set
198 198 240sqmm, 3.5 core A2XFY BI01010001010000000000000515BI0100001308 12 Set
199 199 Supply, installation of sheet steel ladder type cable trays without cover. The rate shall include all supporting brackets, anchor fasteners, screws, bolts, nuts etc.as required. For tray sizes upto 300mm threaded rod support can be considered. For sizes above 300mm angle /channel support shall be considered. \n150mm wide tray (2mm thick ) BI01010001010000000000000515BI0100001309 50 Meter
200 200 300mm wide tray (2mm thick ) BI01010001010000000000000515BI0100001310 75 Meter
201 201 600mm wide tray (2.5 mm thick ) BI01010001010000000000000515BI0100001311 50 Meter
202 202 Supply, installation of sheet steel perforated type GI cable trays with cover. The rate shall include all supporting brackets, anchor fasteners, screws, bolts, nuts etc.as required.\n150mm wide tray (2mm thick /cover 2.5mm thick) BI01010001010000000000000515BI0100001312 25 Meter
203 203 300mm wide tray (2mm thick /cover 2.5mm thick) BI01010001010000000000000515BI0100001313 25 Meter
204 204 Fabricating, supplying, and fixing in position MS steel supports/hangers/runners etc., for supporting the cable trays including all cutting, welding, grinding, anchoring to RCC slabs / walls etc., in approved manner and as required and all incidental work complete. All supports shall be paint finish with 2 quotes of primer and final quote of black paint. BI01010001010000000000000515BI0100001314 1 Meter
205 205 MISCELLANEOUS ITEMS \nSupply and fixing of approval make, 11kV grade, rubber gloves. BI01010001010000000000000515BI0100001315 1 Nos
206 206 Providing and fixing in position approved shock treatment chart written in English and Local Language. The chart shall be framed in Teakwood and covered with glass. BI01010001010000000000000515BI0100001316 2 Nos
207 207 Providing and fixing in position 2.5mm thick 11kV grade, 'rubber mat of approved make and as required by EB authorities and as per IS 15652. BI01010001010000000000000515BI0100001317 25 sq.ft.
208 208 Supply and construct chain link fencing all round the switchyard using steel angle vertical supports of 2.5m height and including and providing 1no. lockable gate as required. BI01010001010000000000000515BI0100001318 35 Meter
209 209 Spreading of 2 layers of 2" size granite stones in the substation as required complete. BI01010001010000000000000515BI0100001319 1 Ls
210 210 Supply and installation of inspection chamber of 750mm x 750mm x1200mm depth with RCC chamber cover as required. BI01010001010000000000000515BI0100001320 4 Set
211 211 Add 12% GST (In Basic Rate must fill 0.12) BI01010001010000000000000515BI0100001321 0.12 Each
212 212 Add 1% Labour cess (In Basic Rate must fill 0.01) BI01010001010000000000000515BI0100001322 0.01 Each