Rural Development Department has published Construction Of Peb Sewing Unit And Ancillary Facilities ( Only Civil , Electrical , Mechanical And Phe Work Of Peb Sewing Unit And Ancillary Facilities ). Submission Date for this Tender is 04-03-2020. PEB Tenders in DUMKA Jharkhand. Bidders can get complete Tender details and download the document.
Name of Work: Construction of PEB Sewing Unit and Ancillary Facilities (Only Civil , Electrical, Mechanical & PHE Work of PEB Sewing unit and Ancillary Facilities). | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | EARTHWORK: Cutting of Trees along with its branches their removal away from work site and stacking \na) Girth above 0.5 m but upto 0.75 m | BI01010001010000000000000515BI0100001111 | 5 | Each |
2 | 2 | Earth work in stripping by hydraulic machinery in grade A&B type of soil. beyond 0.5 km upto 1 km | BI01010001010000000000000515BI0100001112 | 75 | Cum |
3 | 3 | Earth work in stripping by hydraulic machinery in grade A&B type of soil. beyond 1 km upto 2 km | BI01010001010000000000000515BI0100001113 | 7.5 | Cum |
4 | 4 | Earthwork in excavation in foundation trenches in ordinary soil (Wide classification of soil item - A) and disposal of excavated earth | BI01010001010000000000000515BI0100001114 | 185.33 | Cum |
5 | 5 | Extra for earthwork in hard soil as per specification and direction of E/I (vide classificatioNosf soil item _B) | BI01010001010000000000000515BI0100001115 | 74.13 | Cum |
6 | 6 | Filling in foundation trenches and plinth in layers Nost exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed | BI01010001010000000000000515BI0100001116 | 117.15 | Cum |
7 | 7 | Excavating, supplying and Filling of local earth (including royalty) | BI01010001010000000000000515BI0100001117 | 39.05 | Cum |
8 | 8 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. | BI01010001010000000000000515BI0100001118 | 125 | Cum |
9 | 9 | Supplying chemical emulsion in sealed containers including delivery as specified. Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL\nanti-termite treatment (excluding the cost of chemical emulsion) : | BI01010001010000000000000515BI0100001119 | 150 | Liter |
10 | 10 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration | BI01010001010000000000000515BI0100001120 | 150 | Metere |
11 | 11 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm Nosminal size) over 75mm bed of dry brick ballast 40mm Nosminal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. | BI01010001010000000000000515BI0100001121 | 138.75 | Sqm |
12 | 12 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm Nosminal size) | BI01010001010000000000000515BI0100001122 | 42.55 | Sqm |
13 | 13 | P.CC & R.C.C WORK P.C.C . M-100 with Nosminal mix of (1:3:6) in foundation with approved quality of jhama metal and down well graded and local river sand (washed and screened( - iii ------do---- | BI01010001010000000000000515BI0100001123 | 102.78 | Cum |
14 | 14 | Providing R.C.C. M - 200 with Nosminal mix of (1:1.5:3) with approved quality of stone chips 20 mm to 6mm size graded and clean coarse sand of F.M. 2.5 to 3 \nRCC M-200 with nominal mix of (1:1.5:3) In Foundation | BI01010001010000000000000515BI0100001124 | 49.84 | Cum |
15 | 15 | RCC M-200 with nominal mix of (1:1.5:3) 25 mm in Damp proof course | BI01010001010000000000000515BI0100001125 | 42.55 | Sqm |
16 | 16 | Providing 50 mm precast RCC m-200 with Nosminal mix of (1:1.5:3) jali with approved quality | BI01010001010000000000000515BI0100001126 | 43.2 | Sqm |
17 | 17 | Providing Tor steel reinforcement of 8mm,10mm, 12mm & 16 mm. 8,10 mm | BI01010001010000000000000515BI0100001127 | 3 | MT |
18 | 18 | Providing Tor steel reinforcement of 20mm, 28mm & 32 mm. dia bars as per approved design and drawing 12/ 16 mm | BI01010001010000000000000515BI0100001128 | 6 | MT |
19 | 19 | Providing designation 75A one Brick Flat Soling joints with local sand including cost of watering taxes royalty all complete as per building specification & direction of E/I | BI01010001010000000000000515BI0100001129 | 1241.21 | Sqm |
20 | 20 | Providing Random rubble masonry in super structure | BI01010001010000000000000515BI0100001130 | 24.975 | Cum |
21 | 21 | FLOORING and WALL TILING WORKS Providing and laying 25mm. Thick kotah stone slab flooring of approved size, texture and colour over 19mm.thick base of lime morter (1:1:1) (lime putty:surkhi:coarse sand) \n (i) 600x600mm size | BI01010001010000000000000515BI0100001131 | 1231.21 | Sqm |
22 | 22 | Providing and laying 25mm.thick kotah stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12mm.thick cement mortar (1:3) and joined with grey cement slurry | BI01010001010000000000000515BI0100001132 | 21.6 | Sqm |
23 | 23 | Providing and laying 30mm thick White / Yellow sand stone | BI01010001010000000000000515BI0100001133 | 29.4 | Sqm |
24 | 24 | Providing and laying 30mm thick Red sand stone | BI01010001010000000000000515BI0100001134 | 44.1 | Sqm |
25 | 25 | Providing and laying Cool Roof Tiles- 300 x 300 | BI01010001010000000000000515BI0100001135 | 73.5 | Sqm |
26 | 26 | ALUMINIUM WORK Providing and fixing aluminium work for doors, windows, ventilators and partitions | BI01010001010000000000000515BI0100001136 | 476.42 | Kg |
27 | 27 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings | BI01010001010000000000000515BI0100001137 | 346.56 | Kg |
28 | 28 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. With float glass panes of 5 mm thickness | BI01010001010000000000000515BI0100001138 | 171.808 | Sqm |
29 | 29 | FLOOR SPRING | BI01010001010000000000000515BI0100001139 | 28 | Each |
30 | 30 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality | BI01010001010000000000000515BI0100001140 | 680.6 | metre |
31 | 31 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. | BI01010001010000000000000515BI0100001141 | 10 | Each |
32 | 32 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. | BI01010001010000000000000515BI0100001142 | 10 | Each |
33 | 33 | STEEL WORKS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 – part 1 and M.S. top cover of required thickness for rolling shutters. | BI01010001010000000000000515BI0100001143 | 36 | Sqm |
34 | 34 | STEEL WORK (M S GRILL) Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing | BI01010001010000000000000515BI0100001144 | 480 | Kg |
35 | 35 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube | BI01010001010000000000000515BI0100001145 | 137.5 | Kg |
36 | 36 | HORTICULTURE WORKS Spreading of Sludge Farm Yard Manure or/and good Earth (Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately)) | BI01010001010000000000000515BI0100001146 | 27 | Nos |
37 | 37 | Grassing with ' Doobs' Grass (Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed) In rows 7.5 cm apart in either direction | BI01010001010000000000000515BI0100001147 | 50 | Nos |
38 | 38 | Making Lawns including Ploughing and Dragging with 'Swagha' Breaking of Clod (Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm) | BI01010001010000000000000515BI0100001148 | 60 | Nos |
39 | 39 | Maintenance of Lawns or Turfing of Slopes (Maintenance of lawns or Turfing of slopes (rough grassing) for a period of one year including watering etc) | BI01010001010000000000000515BI0100001149 | 60 | Nos |
40 | 40 | a) Planting Permanent Hedges including Digging of Trenches (Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100 metres and supplying and planting hedge plants at 30 cm apart) | BI01010001010000000000000515BI0100001150 | 200 | Nos |
41 | 41 | b)Maintenance of Hedge for one year | BI01010001010000000000000515BI0100001151 | 100 | Nos |
42 | 42 | Planting of Trees and their Maintenance for one Year (Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge mannure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year) | BI01010001010000000000000515BI0100001152 | 25 | Nos |
43 | 43 | Providing and displaying of cephortia Palm plant, having ht. 1.20 m. to 1.50m. with 8-10 suckers, well developed, fresh and healthy lush green leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot & as per direction of the officer-in-charge. | BI01010001010000000000000515BI0100001153 | 50 | Nos |
44 | 44 | LUMPSUM SOFTSCAPE | BI01010001010000000000000515BI0100001154 | 1 | Nos |
45 | 45 | Providing & fixing of White River (Stone) Pables size of 2" to 2.50" dia in natural colour at site of work including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge. | BI01010001010000000000000515BI0100001155 | 5 | qtl |
46 | 46 | Providing and fixing Bamboo jaffery/ fencing consisting of superior quality\n25 mm dia (Average) half cut bamboo placed vertically and fixed together\nwith three numbers horizontal running members of hollock wood in scantling\nof section 50X25 mm, fixed with nails and G.I wire on existing support\ncomplete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001156 | 12.5 | sqm |
47 | 47 | CARRIAGE Sand - 10Km | BI01010001010000000000000515BI0100001157 | 80.78 | Cum |
48 | 48 | S.Chips - 22 Km | BI01010001010000000000000515BI0100001158 | 1.79 | Cum |
49 | 49 | S.Metal - 22km | BI01010001010000000000000515BI0100001159 | 96.61 | Cum |
50 | 50 | PHE WORKS \nEarth work in excavation (As per I.S. 3114/1965 for laying of different types and sizes of pipes so as to give one meter average cover over the socket of pipe with disposal of excavated earth within initial lead and lift as per specification and direction of Engineerin-Charge. \n(a) For classification of Soil item - A | BI01010001010000000000000515BI0100001160 | 0.72 | Cum |
51 | 51 | (b) For classification of Soil item - B | BI01010001010000000000000515BI0100001161 | 1.44 | Cum |
52 | 52 | Earth work in back filling the trenches after laying different types and size of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineerin-Charge. (For classification for Soil item - A & B) | BI01010001010000000000000515BI0100001162 | 3.24 | Cum |
53 | 53 | Extra for earthwork in all kinds of soil for each additional lift of 1m or part there of over the initial lift of 1.5m as per specification and direction of Engineer-in-Charge. | BI01010001010000000000000515BI0100001163 | 3.24 | Cum |
54 | 54 | EXTERNAL WATER SUPPLY Supplying labour and tools for fixing G.I. pipes with Red lead and yarn of following nominal bore with screwed and socketted joints on wall, ceiling and floor including supplying and fitting of wall hooks or pipe clamps, wooden plugs, cutting pipes to size and threading ends if required etc. all complete as per specification and direction of Engineer-in-Charge. (Pipe with socket to be supplied\ndepartmentally free of cost).\n(iii) 25 mm dia nominalbore G. I. pipe | BI01010001010000000000000515BI0100001164 | 20 | Meter |
55 | 55 | (iv) 32 mm dia nominalbore G. I. pipe | BI01010001010000000000000515BI0100001165 | 20 | Meter |
56 | 56 | Supplying and fixing of G.M. ferrule of approved make in existing C.I. main including drilling and taping C.I. main all complete as per specification and direction of Engineer-in-Charge.\n\n(iii)22 mm and 25 mm dia ferrule weight not less than 900 gms | BI01010001010000000000000515BI0100001166 | 1 | Nos |
57 | 57 | Providing and fixing male ended 15mm dia brass bib cock of approved quality (Wt. not less than 350gms.) with extra socket all complete as per specification and direction of E/I. | BI01010001010000000000000515BI0100001167 | 1 | Nos |
58 | 58 | Providing and fixing Gun metal full way valve of approved quality, all complete, as per specification and direction of E/I. \n(d) 32mm dia and weight not less than 700gms. | BI01010001010000000000000515BI0100001168 | 1 | Nos |
59 | 59 | Supplying materials and labour for construction of 600x600x90mm stop cock chamber of brick masonry with 125 mm thick work of designation 75B in cement mortar (1:6) with 12mm thick cement plaster in C.M. (1:6) on inside only having 50 mm thick R.C.C. cover having 12 mm dia lifting rings, 2 nos. stop cock chamber will rest over 80mm thick P.C.C. (1:3:6) over one brick flat soling, including cost of earthwork, all complete job, as per approved design, specification and direction of E/I. | BI01010001010000000000000515BI0100001169 | 3 | Nos |
60 | 60 | INTERNAL WATER SUPPLY SYSTEM \n Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. \n15 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001170 | 30 | Meter |
61 | 61 | 20 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001171 | 45 | Meter |
62 | 62 | 25 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001172 | 10 | Meter |
63 | 63 | 32 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001173 | 5 | Meter |
64 | 64 | 40 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001174 | 5 | Meter |
65 | 65 | External work Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.20 mm nominal outer dia Pipes\n40 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001175 | 2 | Meter |
66 | 66 | 50 mm nominal outer dia Pipes | BI01010001010000000000000515BI0100001176 | 2 | Meter |
67 | 67 | 62.50 mm nominal inner dia Pipes | BI01010001010000000000000515BI0100001177 | 2 | Meter |
68 | 68 | Providing and fixing gun metal gate valve with C.I. wheel of approved\nquality (screwed end) :\n32 mm nominal bore | BI01010001010000000000000515BI0100001178 | 2 | Nos |
69 | 69 | 40 mm nominal bore | BI01010001010000000000000515BI0100001179 | 2 | Nos |
70 | 70 | 50 mm nominal bore | BI01010001010000000000000515BI0100001180 | 2 | Nos |
71 | 71 | 65 mm nominal bore | BI01010001010000000000000515BI0100001181 | 2 | Nos |
72 | 72 | Providing and fixing brass bib cock of approved quality 20 mm nominal bore | BI01010001010000000000000515BI0100001182 | 3 | Nos |
73 | 73 | Providing and fixing brass stop cock of approved quality\n20 mm nominal bore | BI01010001010000000000000515BI0100001183 | 6 | Nos |
74 | 74 | EXTERNAL SEWERAGE Earth work in excavation for laying of different types and sizes of R.C.C. spun pipes with disposal of excavated earth within initial lead and lift as per specification and direction of E/I. | BI01010001010000000000000515BI0100001184 | 20 | Cum |
75 | 75 | Earthwork in back filling the trench after laying different types and sizes of R.C.C. spun pipes with earth removed during excavation within initiallead and lift as per specification and direction of E/I | BI01010001010000000000000515BI0100001185 | 20 | Cum |
76 | 76 | Extra for earthwork in all kinds of soil foreach additional lift of 1M. or part there of over the intial lift of 1.5M. as per specification and direction of E/I. | BI01010001010000000000000515BI0100001186 | 5 | Cum |
77 | 77 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry 'brick honey comb shaft with bricks and S.W. drain pipe 100 mm 'diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001187 | 2 | each |
78 | 78 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:\n100x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001188 | 10 | each |
79 | 79 | 150 x 100 mm size P type | BI01010001010000000000000515BI0100001189 | 10 | each |
80 | 80 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001190 | 6 | Nos |
81 | 81 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001191 | 5 | Nos |
82 | 82 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard designInside dimensions 455x610 mm and 45 cm deep for single pipe lineWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001192 | 3 | Nos |
83 | 83 | Inside dimensions 600x850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 | BI01010001010000000000000515BI0100001193 | 5 | Nos. |
84 | 84 | BORE WELL ,WTP & STP WORKS \nWATER TANK & TERRACE LEVEL WORKS Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Circular tank | BI01010001010000000000000515BI0100001194 | 6000 | Per Ltr |
85 | 85 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in charge,beyond 90 metre & upto 150 metre depth below ground level. \n300 mm dia | BI01010001010000000000000515BI0100001195 | 10 | Meter |
86 | 86 | Rocky strata including Boulders | BI01010001010000000000000515BI0100001196 | 10 | Meter |
87 | 87 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs,\nconforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia | BI01010001010000000000000515BI0100001197 | 20 | Meter |
88 | 88 | Supplying, filling, spreading & leveling stone boulders of size range5 cm to 20 cm, in recharge pit, in the required thickness, for all leads& lifts, all complete as per direction of Engineer-in-charge. | BI01010001010000000000000515BI0100001198 | 10 | Cum |
89 | 89 | Providing and fixing suitable size threaded mild steel cap or spot\nwelded plate to the top of bore well housing/ casing pipe, removable\nas per requirement, all complete for borewell of:150 mm nominal size dia | BI01010001010000000000000515BI0100001199 | 1 | Nos |
90 | 90 | ELECTRICAL \nWIRING SYSTEM Point wiring in PVC conduit, with modular type switch : \nWiring for light point/fan point/exhaust fan point/call bell point with 1.5sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular type switch, switch plate, suitable size GI box etc as required complete. \nGroup C | BI01010001010000000000000515BI0100001200 | 150 | Point |
91 | 91 | Power plug wiring in PVC conduit (2x4sqmm) \nWiring for light/power plug with 2x4sqmm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1no. 4sqmm FR PVC insulated copper conductor single core cable for loop earthing as required. | BI01010001010000000000000515BI0100001201 | 150 | Metre |
92 | 92 | Circuit main wiring in PVC conduit : \nWiring for circuit/submain wiring along with earth wire with the following sizes PVC insulated copper conductor, single core cable in surface /recessed PVC conduit as required. \n2 x 1.5sqmm + 1x1.5sqmm earth wire | BI01010001010000000000000515BI0100001202 | 75 | Metre |
93 | 93 | 2 x 4.0sqmm + 1x4.0sqmm earth wire | BI01010001010000000000000515BI0100001203 | 75 | Metre |
94 | 94 | S/E PVC conduit \nSupplying and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. \n20mm | BI01010001010000000000000515BI0100001204 | 50 | Metre |
95 | 95 | 25mm | BI01010001010000000000000515BI0100001205 | 50 | Metre |
96 | 96 | 32mm | BI01010001010000000000000515BI0100001206 | 25 | Metre |
97 | 97 | S/F Modular type switch / socket \nSupplying and fixing following modular type switch / socket on the existing modular plate and switch box including connection but excluding modular plate etc as required.\n5/6amps, one way switch | BI01010001010000000000000515BI0100001207 | 20 | Each |
98 | 98 | 5/6amps, two way switch | BI01010001010000000000000515BI0100001208 | 3 | Each |
99 | 99 | 15/16amps, one way switch | BI01010001010000000000000515BI0100001209 | 3 | Each |
100 | 100 | 5/6amps, 3 pin socket outlet | BI01010001010000000000000515BI0100001210 | 15 | Each |
101 | 101 | 15/16amps, six pin socket outlet | BI01010001010000000000000515BI0100001211 | 15 | Each |
102 | 102 | Telephone socket outlet | BI01010001010000000000000515BI0100001212 | 5 | Each |
103 | 103 | TV socket outlet | BI01010001010000000000000515BI0100001213 | 3 | Each |
104 | 104 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. \nS/F Modular type blanking plate | BI01010001010000000000000515BI0100001214 | 10 | Each |
105 | 105 | Supplying and fixing blanking plate on the existing modular plate and switch box but excluding modular plate etc as required. | BI01010001010000000000000515BI0100001215 | 50 | Each |
106 | 106 | S/F Modular boxes, base and cover plate \nSupplying and fixing following size modular GI box along with modular base and cover plate for modular switches in recess etc as required.\n 1 or 2 module | BI01010001010000000000000515BI0100001216 | 5 | Each |
107 | 107 | 4 or 5 module | BI01010001010000000000000515BI0100001217 | 100 | Each |
108 | 108 | 6 module | BI01010001010000000000000515BI0100001218 | 10 | Each |
109 | 109 | 8/9 module | BI01010001010000000000000515BI0100001219 | 15 | Each |
110 | 110 | 12 module | BI01010001010000000000000515BI0100001220 | 3 | Each |
111 | 111 | ITC fluorescent fitting directly on the surface \nInstallation, testing and commissioning of prewired fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc directly on ceiling/wall including connection with 1.5sqmm FR PVC insulated copper conductor. | BI01010001010000000000000515BI0100001221 | 50 | Each |
112 | 112 | ITC fluorescent fitting with downrods \nInstallation, testing and commissioning of prewired fluorescent fitting/compact fluorescent fitting of all types, complete with all accessories and tube etc including supplying and fixing ball and socket arrangement 2no. down rods of 20mm dia steel | BI01010001010000000000000515BI0100001222 | 50 | Each |
113 | 113 | ITC ceiling fan \nInstallation, testing and commissioning of ceiling fan, including wiring the downrods of standard length (upto 30cm) with 1.5sqmm FR PVC insulated copper conductor single core cable etc as required. | BI01010001010000000000000515BI0100001223 | 10 | Each |
114 | 114 | Numbering of fan/fittings \nNumbering of ceiling fan/exhaust fan/fluorescent fitting as required. | BI01010001010000000000000515BI0100001224 | 5 | Each |
115 | 115 | ITC exhaust fan upto 450mm sweep \nInstallation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good of the damage, connection, testing, commissioning etc as required. | BI01010001010000000000000515BI0100001225 | 5 | Each |
116 | 116 | Fixing louvers shutters for exhaust fan \nExtra for fixing the louvers shutters complete with frame for a exhaust fan of all sizes | BI01010001010000000000000515BI0100001226 | 5 | Each |
117 | 117 | SWITCH GEARS AND DBs \nS/F SP MCB DB \nSupplying and fixing following way single pole neutral, sheet steel MCB distribution board, 240V on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, DIN bar, detachable gland plate, interconnections, phosphatized and powder painetd including earthing etc as required,(But without MCB/RCCB/Isolator)\n12 way double door | BI01010001010000000000000515BI0100001227 | 2 | Each |
118 | 118 | 16 way double door | BI01010001010000000000000515BI0100001228 | 1 | Each |
119 | 119 | S/F Vertical type TP MCBDB \nSupplying and fixing the following way, three pole and neutral, sheet, MCB distribution board, 415V, on surface/recess, complete with tinned copper busbar, neutral busbar, earth bar, DIN bar, detachable gland plate, interconnections, phosphatized and powder painetd including earthing etc as required,(But without MCB/RCCB/Isolator)\n4way (8+12) Double door, vertical type | BI01010001010000000000000515BI0100001229 | 2 | Each |
120 | 120 | 8way (8+24) Double door, vertical type | BI01010001010000000000000515BI0100001230 | 2 | Each |
121 | 121 | 12way (8+36) Double door, vertical type | BI01010001010000000000000515BI0100001231 | 2 | Each |
122 | 122 | S/F B series SP MCB \nSupplying and fixing 6A to 32A rating, 240V, B series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCBDB complete with connections, testing and commissioning etc as required. 6/32amps, single pole, B series | BI01010001010000000000000515BI0100001232 | 10 | Each |
123 | 123 | S/F C series SP MCB \nSupplying and fixing following rating, 240V, C series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCBDB complete with connections, testing and commissioning etc as required.\n6/32amps, Single pole | BI01010001010000000000000515BI0100001233 | 10 | Each |
124 | 124 | 6/32amps, SPN | BI01010001010000000000000515BI0100001234 | 1 | Each |
125 | 125 | 6/32amps, TPN | BI01010001010000000000000515BI0100001235 | 3 | Each |
126 | 126 | 50/63amps, TPN | BI01010001010000000000000515BI0100001236 | 2 | Each |
127 | 127 | S/F SPMCB blanking plate \nSupplying and fixing single pole blanking plate in existing MCBDB complete as required. | BI01010001010000000000000515BI0100001237 | 10 | Each |
128 | 128 | S/F four pole MCB isolator \nSupplying and fixing following rating four pole, 415V, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required.\n40 amps | BI01010001010000000000000515BI0100001238 | 25 | Each |
129 | 129 | 63 amps | BI01010001010000000000000515BI0100001239 | 25 | Each |
130 | 130 | 80/100 amps | BI01010001010000000000000515BI0100001240 | 10 | Each |
131 | 131 | 125 amps | BI01010001010000000000000515BI0100001241 | 10 | Each |
132 | 132 | Supplying and fixing following rating double pole, 240V, residual current circuit breaker(RCCB) having a sensitivity current upto 300mA in the existing MCBDB complete with connections, testing and commissioning as required.\n16/25 amps | BI01010001010000000000000515BI0100001242 | 1 | Each |
133 | 133 | 40 amps | BI01010001010000000000000515BI0100001243 | 12 | Each |
134 | 134 | 63 amps | BI01010001010000000000000515BI0100001244 | 10 | Each |
135 | 135 | S/F TPN RCCB \nSupplying and fixing following rating TP&N, 415V, residual current circuit breaker(RCCB) having a sensitivity current upto 300mA in the existing MCBDB complete with connections, testing and commissioning as required.\n40 amps | BI01010001010000000000000515BI0100001245 | 4 | Each |
136 | 136 | 63 amps | BI01010001010000000000000515BI0100001246 | 3 | Each |
137 | 137 | S/F 20amps SPN MCB industrial socket outlet \nSupplying and fixing 20amps, 240V, SPN industrial type, socket outlet with 2 poleand earth, metal enclosed plug top along with 20amps C series SP MCB in a sheet steel enclosure, on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc as required. | BI01010001010000000000000515BI0100001247 | 25 | Each |
138 | 138 | P/F danger notice plate \nProviding and fixing M.V danger notice plate of 200mm x 150mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. | BI01010001010000000000000515BI0100001248 | 4 | Each |
139 | 139 | P/F HT danger notice plate \nProviding and fixing M.V danger notice plate of 250mm x 200mm, made of mild steel, at least 2mm thick and vitreous enamelled white on both sides and with inscription in single red colour on front side as required. | BI01010001010000000000000515BI0100001249 | 2 | Each |
140 | 140 | EARTHING GI Earth pipe electrode \nEarthing with GI earth pipe 4.5m long, 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal and salt as required. | BI01010001010000000000000515BI0100001250 | 25 | Set |
141 | 141 | Copper earth plate electrode \nEarthing with copper plate 600mm x 600mm x 6mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc(but without charcoal and salt as required.) | BI01010001010000000000000515BI0100001251 | 5 | Set |
142 | 142 | Salt / coke for plate earth electrode \nExtra for using salt and coke for GI or copper plate earth as required. | BI01010001010000000000000515BI0100001252 | 4 | Set |
143 | 143 | P/F 25mmx5mm copper earth strip in surface/recess \nProviding and fixing 25mmx5mm copper earth strip on surface or in recess for connections etc as required. | BI01010001010000000000000515BI0100001253 | 85 | metre |
144 | 144 | P/F 25mmx5mm GI earth strip in surface/recess \nProviding and fixing 25mmx5mm GI earth strip on surface or in recess for connections etc as required. | BI01010001010000000000000515BI0100001254 | 150 | metre |
145 | 145 | P/F 6SWG GI loop earthing wire in surface/recess \nProviding and fixing 6SWG GI wire on surface or in recess for connections etc as required. | BI01010001010000000000000515BI0100001255 | 100 | metre |
146 | 146 | LV/MV CABLE LAYING (WITH SAND AND PROTECTIVE COVERING)\nMV cable laying upto 25sqmm in ground: \nLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of size not exceeding 25sqmm direct in ground excavation, sand cushioning, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001256 | 50 | Metre |
147 | 147 | MV cable laying upto 400sqmm in ground: \nLaying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1kV grade of size exceeding 120sqmm and not exceeding 400sqmm direct in ground excavation, sand cushioning, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001257 | 25 | Metre |
148 | 148 | HV CABLE LAYING\n11kV cable laying upto 120sqmm in ground: \nLaying of one number PVC insulated PVC sheathed /XLPE power cable of grade exceeding 1.1kV but not exceeding 11kV of size not exceeding 120sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001258 | 5 | Metre |
149 | 149 | 11kV cable laying upto 400sqmm in ground: \nLaying of one number PVC insulated PVC sheathed /XLPE power cable of grade exceeding 1.1kV but not exceeding 11kV, of sizeexceeding 120sqmm and not exceeding 400sqmm direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. | BI01010001010000000000000515BI0100001259 | 5 | Metre |
150 | 150 | Hard rock excavation \nExcavation of trench in hard rock not exceeding 1.5m in width, and lift upto 1.5 m, including getting out the excavated soil and disposal of excavated soil as directed with in a lead of 50m. | BI01010001010000000000000515BI0100001260 | 5 | Cum |
151 | 151 | ROUTE MARKERS \nSupplying and making cable route marker with cement concrete 1:2:4 of size 60cm x 60cm at the bottom and 50cm x 50cm at the top with a thickness of 10cm including inscription duly engraved as required. | BI01010001010000000000000515BI0100001261 | 5 | Each |
152 | 152 | SUPPLY OF MATERIALS PVC INSULATED COPPER CONDUCTOR \n4 pair, 0.5sqmm copper conductor, FR PVC insulated, unarmoured telephone cable | BI01010001010000000000000515BI0100001262 | 50 | Metre |
153 | 153 | Co-axial TV cable RG6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with FR PVC sheath. | BI01010001010000000000000515BI0100001263 | 50 | Metre |
154 | 154 | PVC/XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100volts \n6sqmm, 2 core | BI01010001010000000000000515BI0100001264 | 50 | Metre |
155 | 155 | 10sqmm, 2 core | BI01010001010000000000000515BI0100001265 | 25 | Meter |
156 | 156 | 10sqmm, 4 core | BI01010001010000000000000515BI0100001266 | 50 | Metre |
157 | 157 | 16sqmm, 4 core | BI01010001010000000000000515BI0100001267 | 12 | Metre |
158 | 158 | 25sqmm, 3.5 core | BI01010001010000000000000515BI0100001268 | 75 | Metre |
159 | 159 | 35sqmm, 3.5 core | BI01010001010000000000000515BI0100001269 | 25 | Metre |
160 | 160 | 50sqmm, 3.5 core | BI01010001010000000000000515BI0100001270 | 50 | Metre |
161 | 161 | 185sqmm, 3.5 core | BI01010001010000000000000515BI0100001271 | 25 | Metre |
162 | 162 | 240sqmm, 3.5 core | BI01010001010000000000000515BI0100001272 | 50 | Metre |
163 | 163 | Excavation and refilling (as per SOR 2018) | BI01010001010000000000000515BI0100001273 | 250 | Metre |
164 | 164 | CEILING FAN / WALL FAN / EXHAUST FANS \nCeiling fan 1200mm | BI01010001010000000000000515BI0100001274 | 2 | Each |
165 | 165 | 15" (380mm) metal exhaust fan | BI01010001010000000000000515BI0100001275 | 20 | Each |
166 | 166 | LED FITTINGS \nrecess mounting LED round down light (15/16W) | BI01010001010000000000000515BI0100001276 | 3 | Each |
167 | 167 | Recess mounting LED TUBE light (18/20W) | BI01010001010000000000000515BI0100001277 | 40 | Each |
168 | 168 | Recess mounting LED Panel light 2' x 2' (36W) | BI01010001010000000000000515BI0100001278 | 5 | Each |
169 | 169 | LED Street light (30W) | BI01010001010000000000000515BI0100001279 | 20 | Each |
170 | 170 | LED Flood light (120W) | BI01010001010000000000000515BI0100001280 | 1 | Each |
171 | 171 | Non-Schedule Item. | BI01010001010000000000000515BI0100001281 | ||
172 | 172 | MISCELLANEOUS WORKS \nDrinking water kiosks Frame will be MS and Panel will be of ACP. Kiosk will be designed in the way that Raw water storage tank, RO, Chiller and pure water storage, tank can be fixed inside it. Acquires very less space. Best suitable for all Urban & Rural areas Minimum space required- 4 feet* 4 feet* 10 feet. Ground water recharge system (Optional) Solar panel can be enabled (optional) | BI01010001010000000000000515BI0100001282 | 4 | Nos |
173 | 173 | Supplying and fixing GI angle iron brackets, hangers, supports for maintenance as per detail drawing for supporting sewerage, rain water and water supply pipes in shafts with suitable MS clamps, bolts, nuts and washers, fixed on shaft walls etc. complete. | BI01010001010000000000000515BI0100001283 | 200 | kgs |
174 | 174 | Supplying materials and constructing rain water harvesting recharge pits of 1.2 m dia and 3 m depth with RCC Precast rings including excavation and graded aggregate packing around the rings 300 mm thick with all lead and lift etc., complete as directred by the Engineer in charge | BI01010001010000000000000515BI0100001284 | 4 | Nos |
175 | 175 | Supplying, fixing and testing PVC soil, waste and vent pipes (SWR) confirming to IS13592 :1992, type B with rubber ring (confirming IS:5382) joint inclusive of all necessary specials like bends, tees, offsets, door ends, junctions, cowls, etc., laid velow ground, complete. The quoted rate should include necessary PCC supports.'a) 110mm dia | BI01010001010000000000000515BI0100001285 | 20 | Meter |
176 | 176 | INTERNAL SEWAGE SYSTEM \nSupplying, fixing and testing PVC soil, waste and vent pipes (SWR) confirming to IS13592 :1992, type B with rubber ring (confirming IS:5382) joint inclusive of all necessary specials like bends, tees, offsets, door ends, junctions, cowls, etc., laid under floor/fixed on walls, and in pipe shafts etc., complete. The quoted rate should include necessary MS angle supports, grip bolts and clamps etc.,a) 110mm dia | BI01010001010000000000000515BI0100001286 | 25 | Meter |
177 | 177 | b) 75 mm dia | BI01010001010000000000000515BI0100001287 | 25 | Meter |
178 | 178 | c) 50 mm dia - 10kg/sqcm-wash basin/Sink | BI01010001010000000000000515BI0100001288 | 10 | Meter |
179 | 179 | d) 40mm dia- 10kg/sqcm-wash basin | BI01010001010000000000000515BI0100001289 | 25 | Meter |
180 | 180 | e) 63mm dia ( type A) | BI01010001010000000000000515BI0100001290 | 10 | Meter |
181 | 181 | Supply and fixing SWR PVC Plain/multi floor traps of `P' or `S' type with SS grating (heavy quality hopper type with frame) and 75mm outlet with necessary water proofing after fixing. ( FOR URINALS- Supplying, fixing and testing of 75mm PVC P trap for urinals with fabricating boss connection for inlet pipe, with SS frame and grating 75mm dia. outlet, fixed below slab suspended to the ceiling, including connection pipe, necessary support etc. complete0 (Heavy duty type) | BI01010001010000000000000515BI0100001291 | 6 | Nos |
182 | 182 | Supplying, fixing and testing PVC rain water collection kurra with leaf trap grating made out of UPVC with flange complete. (Terrace rain water )a) 110mm dia- Side entry | BI01010001010000000000000515BI0100001292 | 2 | Nos |
183 | 183 | Supply, Installation & Commissioning of Sewage \nTreatment Plant of Capacity 2 KLD.\nSystem- SBR type | BI01010001010000000000000515BI0100001293 | 1 | Set |
184 | 184 | Supply, lowering & installation of RCC readymade humepipe septic tank at suitable location including earth work excvation in all types of soil, necessary pcc bedding as directed including sewerline connections at inlet & outlet, Inspection Chambers etc., complete as per standard design & as directed. \n50 User Capacity | BI01010001010000000000000515BI0100001294 | 1 | Set |
185 | 185 | Providing, fixing and commissioning suitable complete Pumping system consisting of horizontal /vertical multistage centrifugal pump having stainless steel (SS 304) impellers, shaft (SS-316) and housing, with single mechanical seal and pressurised tank of 100 liters capacity, complete with all standard accessories.\nNo. of Pumps : 2 (1 working + 1 stand by) \nCapacity : 100lpm of Each Pump \nHead : 20 m \n \n | BI01010001010000000000000515BI0100001295 | 1 | Set |
186 | 186 | Supply, Installation & Commissioning of Water Treatment Plant of Capacity 3.5 KLD.\nSystem Consists :- \nFeed Pumps 2 nos, Pressure sand filter, Activated Carbon Filter, Softner, UV Sterlizer, complete frontal piping & Valves, Control Panel with necessary etc.\nNos of Streams-1\nProduct Flow - 0.5 m3/ hr | BI01010001010000000000000515BI0100001296 | 1 | Set |
187 | 187 | Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse\nsand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :\n0.91 m deep with SFRC cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement\n: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) :\nWith common burnt clay F.P.S. (non modular)\nbricks of class designation 7.5 | BI01010001010000000000000515BI0100001297 | 4 | Nos |
188 | 188 | LT PANEL BOARDS \nSupply, installation, testing and commissioning of M.V.Distribution Boards suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be free standing, floor mounting, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi tier arrangement. A minimum of 400mm clearance shall be given from the floor level to the bottom most termination point. The painting shall be done in conformity with IS code. \nAdequate size cable alley shall be provided all round the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Flexible cable links are not acceptable. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. The copper earth strip of adequate size in 2runs shall run throught out the perimeter of the bottom of the panel. The panel shall be fabricated only after the approval of fabrication drawings by the consultant.\nAll MCB used for lighting loads shall be B curve, motor loads shall be C curve and used for computer or any thyristor loads shall be D curve. \nAll potential free contacts for Breakers " ON" "OFF" " TRIP" will be wired with required connector suitable for BMS cable termination. | BI01010001010000000000000515BI0100001298 | 1 | Set |
189 | 189 | APFC (75kVAr) \nAPFC panel comprises :\nOne (1) - Incomer feeder having : \nOne (1) - 200A, TPN, 25kA, MCCB. The MCCB shall be microprocessor based with trip free feature with ON, OFF and TRIP indications, with 2NO+2NC auxiliary contacts, terminal shrouds, sliding type front operation kit with shunt trip release, overload (adjustable), short circuit and earth fault releases. \nOne (1) - 0-200A analog Ammeter with selector switch, Cl1.o, flush mounting.\nThree (3) - 200/5A, 5VA, Cl 1.0, CTs\nOne (1)- 6 stage automatic power factor control relay as required. \nOne (1) lot indicating lamps and push buttons for ON / OFF control / indication of the capacitors and three phase indicating lamps.\nOutgoing feeders | BI01010001010000000000000515BI0100001299 | 1 | Set |
190 | 190 | LT CABLES END TERMINATIONS AND CABLE TRAYS. \nProviding & Install cable terminations for the above cables including double compression type chrome plated brass glands and lugs(crimping type), gland earthing, PVC taping as required and all accessories complete.\n6sqmm, 2 core, A2XWY | BI01010001010000000000000515BI0100001300 | 100 | Set |
191 | 191 | 10sqmm, 2 core A2XWY | BI01010001010000000000000515BI0100001301 | 4 | Set |
192 | 192 | 10sqmm, 4 core A2XWY | BI01010001010000000000000515BI0100001302 | 10 | Set |
193 | 193 | 16sqmm, 4 core A2XWY | BI01010001010000000000000515BI0100001303 | 4 | Set |
194 | 194 | 25sqmm, 3.5 core A2XFY | BI01010001010000000000000515BI0100001304 | 10 | Set |
195 | 195 | 35sqmm, 3.5 core A2XFY | BI01010001010000000000000515BI0100001305 | 12 | Set |
196 | 196 | 50sqmm, 3.5 core A2XFY | BI01010001010000000000000515BI0100001306 | 4 | Set |
197 | 197 | 185sqmm, 3.5 core A2XFY | BI01010001010000000000000515BI0100001307 | 2 | Set |
198 | 198 | 240sqmm, 3.5 core A2XFY | BI01010001010000000000000515BI0100001308 | 12 | Set |
199 | 199 | Supply, installation of sheet steel ladder type cable trays without cover. The rate shall include all supporting brackets, anchor fasteners, screws, bolts, nuts etc.as required. For tray sizes upto 300mm threaded rod support can be considered. For sizes above 300mm angle /channel support shall be considered. \n150mm wide tray (2mm thick ) | BI01010001010000000000000515BI0100001309 | 50 | Meter |
200 | 200 | 300mm wide tray (2mm thick ) | BI01010001010000000000000515BI0100001310 | 75 | Meter |
201 | 201 | 600mm wide tray (2.5 mm thick ) | BI01010001010000000000000515BI0100001311 | 50 | Meter |
202 | 202 | Supply, installation of sheet steel perforated type GI cable trays with cover. The rate shall include all supporting brackets, anchor fasteners, screws, bolts, nuts etc.as required.\n150mm wide tray (2mm thick /cover 2.5mm thick) | BI01010001010000000000000515BI0100001312 | 25 | Meter |
203 | 203 | 300mm wide tray (2mm thick /cover 2.5mm thick) | BI01010001010000000000000515BI0100001313 | 25 | Meter |
204 | 204 | Fabricating, supplying, and fixing in position MS steel supports/hangers/runners etc., for supporting the cable trays including all cutting, welding, grinding, anchoring to RCC slabs / walls etc., in approved manner and as required and all incidental work complete. All supports shall be paint finish with 2 quotes of primer and final quote of black paint. | BI01010001010000000000000515BI0100001314 | 1 | Meter |
205 | 205 | MISCELLANEOUS ITEMS \nSupply and fixing of approval make, 11kV grade, rubber gloves. | BI01010001010000000000000515BI0100001315 | 1 | Nos |
206 | 206 | Providing and fixing in position approved shock treatment chart written in English and Local Language. The chart shall be framed in Teakwood and covered with glass. | BI01010001010000000000000515BI0100001316 | 2 | Nos |
207 | 207 | Providing and fixing in position 2.5mm thick 11kV grade, 'rubber mat of approved make and as required by EB authorities and as per IS 15652. | BI01010001010000000000000515BI0100001317 | 25 | sq.ft. |
208 | 208 | Supply and construct chain link fencing all round the switchyard using steel angle vertical supports of 2.5m height and including and providing 1no. lockable gate as required. | BI01010001010000000000000515BI0100001318 | 35 | Meter |
209 | 209 | Spreading of 2 layers of 2" size granite stones in the substation as required complete. | BI01010001010000000000000515BI0100001319 | 1 | Ls |
210 | 210 | Supply and installation of inspection chamber of 750mm x 750mm x1200mm depth with RCC chamber cover as required. | BI01010001010000000000000515BI0100001320 | 4 | Set |
211 | 211 | Add 12% GST (In Basic Rate must fill 0.12) | BI01010001010000000000000515BI0100001321 | 0.12 | Each |
212 | 212 | Add 1% Labour cess (In Basic Rate must fill 0.01) | BI01010001010000000000000515BI0100001322 | 0.01 | Each |