Military Engineer Services-MES has published Repair Maintenance Replacement Of Unsv Diesel Generator Set Spares Amf Panel Solar Water Heater And Pipe Line And Connected Works At Af Station Bihta. Submission Date for this Tender is 02-06-2020. Diesel Generators Tenders in GE AF Bihta Bihar. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-Mar-2020 | corrigendum01 | Date | 24-03-2020 |
2 | 24-Mar-2020 | corrigendum-03 | Date | 06-04-2020 |
3 | 01-Apr-2020 | corrigendum-04 | Date | 20-04-2020 |
4 | 16-Apr-2020 | corrigendum-05 | Date | 16-05-2020 |
5 | 06-May-2020 | corrigendum-06 | Date | 26-05-2020 |
6 | 26-May-2020 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-06-2020 |
Name of Work: REPAIR/MAINT/REPLACEMENT OF UNSV DG SET SPARES, AMF PANEL, SOLAR WATER HEATER AND PIPE LINE AND CONNECTED WORKS AT AF STATION BIHTA. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | M&L for inspection, maintanance and servicing of complete DG Set of capacity between 15-75 KVA (Inspection & Maintenance comparising of Engine/ Alternator/ Control panel) including replacement of unserviceable spare parts where required, for smooth functioning of DG Set through the representatives of authorised dealer/OEM of Kirloskar and cummins complete all as per manufacturers instructions and as directed by Engineer-in-Charge as under :- \nMake of DG Set : Kirloskar and Cummins\n(A). 'A' Check (a) Lubricating oil condition (b) Engine oil and water leakage (c) Mounting structure of DG Set and other nut bolts of engine and alternator (d) Fan Belts and their adjustment required for smoothe operation of driver (e) cleaning of air filters (f) Adjusment of valve clearance (g) change of oil/Fuel filters and engine oil if necessary (h) solonoid switch, battery and battery charger (j) cooling system and fuel system \n(k) checking of all power cables and AVR connections etc (l) control panel meters and functioning of gadgets (m) functioning of control and safety system. \n(B) 'B' Check (a) Flexible coupling of engine and alternator (b) cleaning of crank case ventilation pipe (c) checking of injectors and fuel pump (d) checking of alternator and carbon brushes etc. \nNote. (a) The cost of spares required for maintenance shall be measured and paid separtely under relevant items \n(b) Spare parts shall only be purchased from the authorised dealers. | 10 | EACH JOB | |
2 | 2 | M&L for inspection, maintanance and servicing of AMF panel of any capacity of DG Set in between 40-75 KVA for trouble free functioning as required at site including replacement of unserviceable spare parts complete comprising of (a) Checking all electrical connections(b) Checking all contact point/ Bus bars(c) Checking / replace timers (AC or DC)(d) Checking / replace buttons(e) Checking / replace selector switch (f) Checking / replace indicator lamps(g) Checking / replace main / auxiliary contacts / relays(h) Checking / replace contact coil(j) Checking / replace of volt/amps meters (k) Checking auto/manual function(l) Check battery charger out put voltage(m) Cleaning the panel HRC fuses and connections complete \nNote. (a) The cost of spares required for maintenance shall be measured and paid separtely under relevant items \n(b) Spare parts shall only be purchased from the authorised dealers. | 9 | EACH JOB | |
3 | 3 | S & F Oil Filter suitable Cummins DG Set 40 KVA . Cat part No - 0122 0922 Make- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
4 | 4 | S & F Oil Filter suitable for DG Set 15 to 70 KVA. Make : Kirloskar\nMake- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
5 | 5 | S & F Element Air filter (Inner)suitable for 40 KVA DG Set Cummins. \nCat part No -A034P656 Make- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
6 | 6 | S & F Element Air filter (Inner) suitable for 62.5to 70 KVA DG Set Make:Kirloskar. Make- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
7 | 7 | S & F Element Air filter (Outer) suitable for 40 KVA DG Set Cummins. \nCat part No -A034P660 Make- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
8 | 8 | S & F Element Air filter (Outer) suitable for 62.5to 70 KVA DG Set Make:Kirloskar. Make- Kirloskar/ Mico /Falcon/AGS etc | 5 | EACH | |
9 | 9 | Supply only inhibitor Corrosion suitable for 40 KVA DG Set Cummins. \nCat part No -3816986 (in 5 Ltr container)\n | 5 | EACH | |
10 | 10 | Supply only inhibitor Corrosion suitable for 62.5 to 70 KVA DG Set Make:Kirloskar (in 5 Ltr container) \n | 5 | EACH | |
11 | 11 | Supply only Engine Oil 15W 40 (Valvoline premium Blue 7600) \n(in 55 Ltr container ) Cat part No : 505060 Make : Volvolin. | 220 | LITRE | |
12 | 12 | Supply only separator fuel water suitable for 40 KVA DG Set \nMake : Cummins. Cat part No -4093731 (in 5 Ltr container)\n | 9 | EACH | |
13 | 13 | S & F dynamo fan belt set suitable for for DG Set 62.5 to 75 KVA Make : Kirloskar (2.00 to 2.50 for belts) \nMake: - Kirloskar, /Power king/power grip GTX/dunlop | 6 | EACH | |
14 | 14 | S & F dynamo fan belt set suitable for for DG Se 40 KVA Make : Cummens | 4 | EACH | |
15 | 15 | S & F water pump suitable for 62.5 to 75 KVA DG Set Make :Kirloskar,\nMake : Kirloskar /Power king/power grip GTX/dunlop | 3 | EACH | |
16 | 16 | S & F water pump suitable for for DG Se 40 KVA Make : Cummens | 3 | EACH | |
17 | 17 | S & F water hose pipe set with clamps suitable for 62.5 - 70 KVA DG Set Make : Kirloskar | 2 | SET OF 2 | |
18 | 18 | S & F water hose pipe set with clamps suitable for40 KVA DG Set Make : Cummins | 2 | SET OF 2 | |
19 | 19 | S & F Relay suitable for Kirloskar Make DG Set 62.5-70 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing complete all as directed.\nMake: L&T , Siemens or equivalent\n | 8 | EACH | |
20 | 20 | S & F Relay suitable for Kirloskar Make DG Set 62.5-70 KVA (existing type & voltage -240 Volts AC) in AMF panel and making connections including testing complete all as directed.\nMake: L&T , Siemens or equivalent\n | 6 | EACH | |
21 | 21 | S & F Auxiliary contact suitable for Kirloskar Make DG Set 62.5-70 KVA (Existing type) with logic units. \nMake: L&T/Legrand/ Havells/ Siemens\n | 6 | EACH | |
22 | 22 | S & F Main contactors four pole, 220 Volt suitable for 75 KVA DG set of existing model complete all as directed. Make- L&T Havells, legrand etc | 6 | SET OF 2 | |
23 | 23 | S & F SMPS unit suitable for DG Set 62.5 - 70 KVA DG Set for battery charging including making connections and testing etc complete as specified and as directed. \n(Note : The SMPS shall only be purchased from the authrised dealer) | 2 | EACH | |
24 | 24 | M&L for preparation of old surfaces of aquastic enclousers, cleaning dust, dirts, etc. filling Cavities with filler compound and applying two coat of DUCCO paint with existing colour by using spray machine gun including writting SM/MES No. with white paint complete all as specified and as directed. | 2 | EACH JOB | |
25 | 25 | M & L for replacement of damaged AMF panel wiring with 1.5/2.5 Sqmm copper conductor FRHS as per existing including replacement of cable treys of existing size and copper thimbles etc complete all as specified and as directed. | 2 | EACH JOB | |
26 | 26 | M & L for complete dismantling and servicing of existing unsv solar water heater and collector panel of capacity 100 LPD of any Make with electric back up system after disconnecting the existing water supply/water connection from any height of the building/ ground, including stripping out the hot water vessel by taking out, outer cover, insulating materials etc and continuous brazing /welding of the inner container where required for arresting leakages including replacemnt of defective / worn out spare parts etc and re-assembling the system connecting the water/ electrial connections complete and testing upto the satisfaction of Engr-in-Charge.\nNOTE:-(i) Cost of minor defective /worn out spares is deemed to be included in the quoted rate for this item.\n(ii) Cost for servicing of flat plate collector is also deemed to be included in the quoted rate. Major spares shall be measured and paid separately.\n(iii) Servicing of solar water heater shall be got through the authorised dealer of M/S RASHMI Idustries, Bangalore or original Equipment Manufacturer to avoid any defect.\n | 5 | EACH JOB | |
27 | 27 | -ditto- all as per Ser item No 26 above but for solar water heater capacity 200/300 lts/day. | 4 | EACH JOB | |
28 | 28 | M & L for replacement of damaged framed work as in ladder of angle or other section with gusser plate, rails, braces etc complete drilled for fixing of steel including hanging, welding and also fastening complete all as specified and as directed. | 100 | KILOGRAM | |
29 | 29 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and as directed. | 142 | CUBIC METRE | |
30 | 30 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick complete all as specified and directed. | 35.5 | CUBIC METRE | |
31 | 31 | Removing of excavated material n, exc 50 mtr away and depositing where directed at a level n, exc 1.5 mtr above the starting point complete all as specified. | 106.5 | CUBIC METRE | |
32 | 32 | Providing precast slab of cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate set in cement mortar | 4 | CUBIC METRE | |
33 | 33 | M&L for PCC 1:3:6 type C-1 using 20mm graded aggregate mechanically crushed stone for mass filling/patching work in pole copping including making smooth surface matching with existing coping complete all as specified. | 3 | CUBIC METRE | |
34 | 34 | M & L brick work with sub class 'B' brick straight or curved on plan exceeding 6m mean radious built in CM 1:4 complete all as specified and as directed. | 4 | CUBIC METRE | |
35 | 35 | S & F in replacement of unsv/damaged GI tubing 15mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. | 60 | RUNNING MMETRE | |
36 | 36 | S & F in replacement of unsv/damaged GI tubing 20mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. | 60 | RUNNING MMETRE | |
37 | 37 | S & F in replacement of unsv/damaged GI tubing 25mm bore medium grade galvanised with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and as directed. | 60 | RUNNING MMETRE | |
38 | 38 | S & F in replacement of unsv/damaged hot water pipe line 15mm bore insulated with glass wool and aluminium cladding complete all as specified and directed. | 120 | RUNNING MMETRE | |
39 | 39 | S & F in replacement of unsv/damaged gun metal globe or gate valve of 15mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. | 9 | EACH | |
40 | 40 | S & F in replacement of unsv/damaged gun metal globe or gate valve of 20mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. | 9 | EACH | |
41 | 41 | S & F in replacement of unsv/damaged gun metal globe or gate valve of 25mm sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and as diected. | 9 | EACH | |
42 | 42 | S & F in replacement of unsv/damaged 15mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed. | 5 | EACH | |
43 | 43 | M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armored electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 2 core to be laid in existing cable trench/under road/along poles/through pipe etc complete all as specified and as directed. | 300 | RUNNING MMETRE | |
44 | 44 | M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armored electric power cable (heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 4 core to be laid in existing cable trench/under road/along poles/through pipe etc complete all as specified and as directed. | 200 | RUNNING MMETRE | |
45 | 45 | S & F in replacement of unsv isolator/MCB SPN 40 Amps with MCB DB 220 volts 2 way complete all as specified and as directed. | 6 | EACH | |
46 | 46 | S & F in replacement of unsv isolator/MCB TPN 32 Amps with MCB DB 220 volts 4 way complete all as specified and as directed. | 6 | EACH | |
47 | 47 | S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 100 LPD Non standard 1 No | 2 | EACH | |
48 | 48 | S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 200 LPD Non standard 1 No and standard 1 No | 2 | EACH | |
49 | 49 | S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 300 LPD Non standard 1 No and standard 2 No | 2 | EACH | |
50 | 50 | S & F in replacement of broken/defective solar water heater storage tank for 100 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. | 2 | EACH | |
51 | 51 | S & F in replacement of broken/defective solar water heater storage tank for 200 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. | 2 | EACH | |
52 | 52 | S & F in replacement of unsv hot water out let hose pipe of standard length. | 10 | EACH | |
53 | 53 | S & F in replacement of unsv cold water in let hose pipe of standard length. | 10 | EACH | |
54 | 54 | S & F in replacement of broken/defective solar water heater storage tank for 300 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and as directed. | 1 | EACH | |
55 | 55 | S & F in replacement of unsv/damaged Heating element with rubber gasket threaded /push type, 230 Volts, 1.5/2.00 KW and making necessary electrical connections, testing complete all as directed. Make of element : Toshiba/Bajaj or equivalent. | 6 | EACH | |
56 | 56 | S&F inter locking ring, clip type suitble for rubber pipe complete all as directed. | 40 | EACH | |
57 | 57 | M & L for cleaning of over head reservoir internally from base to top including scraping the mud silt from base and walls, washing the complete internal surfaces with bleaching powder, antibacterial sodium hypochlorite solution to inner surface with clean water ,removing the silt/mud water out side the tank and desilting from connecting pipes and applying internally one coat of lime wash to RCC walls ,base of tanks of 50000 gallons upto 30 mtrs staging complete & writing details of cleaning in prescribed format complete all as specified and as directed \nLocation : Pump House No 2 | 1 | EACH JOB | |
58 | 58 | Description all as per item Ser No 57 above but for 75000 gallons \nLocation : Pump House No 3 | 1 | EACH JOB | |
59 | 59 | Description all as per item Ser No 57 above but for 5000 gallons \nLocation : Tropo & Ops Area | 2 | EACH JOB | |
60 | 60 | M&L for preparation of new wall/ plastered surfaces and applying two coats of cement base paint on RCC over head tanks upto 25 mtr height complete all as specified and directed by Engr-in-Charge | 120 | SQUARE METRE | |
61 | 61 | M/L for two coats of synthetic enamel paint over a coat of red-oxide primer including preparation of old rusted surface of steel exc 10 cm width/grith at any height of tank and water supply vertical pipes of pumping and distribtion lines as per existing colour code and marking of Arrow for flowing of water with black/white paint complete all as specified and as directed. | 10 | SQUARE METRE | |
62 | 62 | S & F in replacement of old unsv panel inbuilt star delta starter assembly complete suitable for 30/35HP sub mersible pumping set fixed in LT control panel of pump house including replacement of existing unsv panel wirings and accessories complete all as specified and as directed. Make : Havells/Schneider/ABB | 4 | EACH | |
63 | 63 | S & F in replacement of water level indicator with sensor suitable for 75000 Galon over head RCC tank and making electrical connections and testing complete all as specified and as directed. | 2 | Each Set | |
64 | 64 | S & F in replacement of damaged/unsv water level sensor with controller unit not less than 10 mtr where directed and testing upto the satisfaction of Engr-in-Charge. | 2 | Each Set | |
65 | 65 | S & F in replacement of unsv injector dozing pump working in 230V single phase, 50 Hz, , flow rate 0-20 Ltr/Hr, Pressure - 10 Kg/cm2 where directed including making connections with existing dozing line and testing upto the satisfaction of Engr-in-Charge. \nMake : Sree Rayalaseema Hi-Strength Hypo Ltd/ Ramco | 2 | EACH | |
66 | 66 | S & F in replacement of old unsv agitator motor, 120W, single phae, 220 V AC, 50 Hz, 6 pole, 960 PM where directed and testing upto the satisfaction of Engr-in-Charge complete all as specified and as directed. \nMake : Ravi Enterprises or equivalent in RAMCO/Decli-back.. | 2 | EACH | |
67 | 67 | S & F in replacement of old unsv rotary switch of dozing pump (as per existing sample) and testing upto the satisfaction of deptt. | 2 | EACH | |
68 | 68 | M & L for strip opening of submersible pumping set and prepare the surface for rewinding of burnt submersible pumping set of capacity 25/30HP capacity with the existing gauge of copper winding wire with same insulation including replacement of bearings complete all as per standard norms and testing upto the satisfaction of Engr in-charge. \nNote. Contractor shall give gurantee certificate for one year from the date of installation of motor. | 1 | EACH JOB | |
69 | 69 | M & L Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot)\ncollars, caps and plugs upto 150mm bore for spigot socketed pipes. | 100 | KILOGRAM | |
70 | 70 | M & L Bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged upto 150mm bore for flanged pipes. | 100 | KILOGRAM | |
71 | 71 | Taking out old unserviceable 80mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). | 200 | RUNNING MMETRE | |
72 | 72 | Taking out old unserviceable 50mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). | 200 | RUNNING MMETRE | |
73 | 73 | Taking out old unserviceable 25mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). | 150 | RUNNING MMETRE | |
74 | 74 | Taking out old unserviceable 20mm dia GI tubing with all fittings from trenches, walls, floors etc complete all as specified and as directed.\n(Note : Excavation & earth work will be measured & paid seperately under respective item ). | 150 | RUNNING MMETRE | |
75 | 75 | M & L for GI pipe medium grade with all fittings laid in trenches 80mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n | 150 | RUNNING MMETRE | |
76 | 76 | M & L for GI pipe medium grade with all fittings laid in trenches 50mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n | 150 | RUNNING MMETRE | |
77 | 77 | M & L for GI pipe medium grade with all fittings laid in trenches 25mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n | 100 | RUNNING MMETRE | |
78 | 78 | M & L for GI pipe medium grade with all fittings laid in trenches 20mm bore medium grade ISI Marked of following sizes with all fittings complete all as specified and as directed by Engineer-in-Charge. \n | 100 | RUNNING MMETRE | |
79 | 79 | Laying only, testing and connecting in trenches GI pipe 80mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. \n | 50 | RUNNING MMETRE | |
80 | 80 | Laying only, testing and connecting in trenches GI pipe 50mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. . \n | 50 | RUNNING MMETRE | |
81 | 81 | Laying only, testing and connecting in trenches GI pipe 25mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge. Note:- GI pipe obtained from taking down shall be used. \n | 50 | RUNNING MMETRE | |
82 | 82 | Laying only, testing and connecting in trenches GI pipe 20mm bore medium grade ISI Marked with all fittings complete all as specified and as directed by Engineer-in-Charge.Note:- GI pipe obtained from taking down shall be used. \n | 50 | RUNNING MMETRE | |
83 | 83 | S & F Gun metal gate valve 50 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. | 5 | EACH | |
84 | 84 | S & F Gun metal gate valve 40 mm ISI marked with iron wheel screwed down high pressure screwed both ends for iron pipe incl taking down old unserviceable complete all as specified and directed by Engineer-in-Charge. | 5 | EACH | |
85 | 85 | M&L for lead wool joints for 150mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
86 | 86 | M&L for lead wool joints for 100mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
87 | 87 | M&L for lead wool joints for 80mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
88 | 88 | M&L for run lead joints for 150mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
89 | 89 | M&L for run lead joints for 100mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
90 | 90 | M&L for run lead joints for 80mm dia spigot and socket pipes and fittings with all jointing materials like spun yarn etc complete all as specified and directed. | 5 | EACH | |
91 | 91 | Material & Labour for brick masonry valve pit internal size 1200mm x 1200mm x 1200mm with one brick thick wall using sub class ‘B’ brick in cement mortar 1:6 over 20cm thick PCC plate form with 15cm off sets on every side of 1:3:6 type C-1 including plastering of internal surfaces and exposed surfaces with 15mm thick plastering in cement mortar 1:4 and 50mm thick RCC cover (in two equal parts 1:2:4 type B-1 with 10mm dia deformed bars at 10cm interval on both side including necessary form work with 150mm dia hole in the center complete all as specified and as directed by Engineer-in-Charge | 2 | EACH JOB | |
92 | 92 | Description all as per ser item No 91 here-in-before but of size 900mm x 900mm x 900 -ditto- | 2 | EACH JOB | |
93 | 93 | Description all as per ser item No 91 here-in-before but of size 600mm x 600mm x 600m -ditto- | 2 | EACH JOB | |
94 | 94 | Supply and fixing in replacement of butterfly valve, lever operated, pressure rating PN-1.6, water type nitrile rubber lining, suitable insertion between flange ends, 150mm nominal bore ISI marked complete with MS tail pieces double side flanged incuding welding work as per site requirement, rubber/fiber board gasket, nut & bolt, washers etc complete all as specified and directed by Engr-in-Charge Make : BIR/L&T/ZOLOTO/Ramco | 6 | EACH | |
95 | 95 | Description all as per ser item No 94 here-in-before but of 100 mm bore | 8 | EACH | |
96 | 96 | Description all as per ser item No 94 here-in-before but of 80 mm bore | 7 | EACH | |
97 | 97 | M & L for rubber gasket (Tyton) joints suitable for 150mm bore DI pipe and fittings including jointing material complete all as specified and as directed. | 10 | EACH | |
98 | 98 | S & F flanged joints complete with rubber or fiberboard gasket , nuts, washers for 150mm bore pipe fittings complete all as specified and as directed. | 5 | EACH | |
99 | 99 | Description all as per ser item No 98 here-in-before but of 100 mm bore | 5 | EACH | |
100 | 100 | Description all as per ser item No 98 here-in-before but of 80 mm bore | 5 | EACH | |
101 | 101 | Material & labour PCC 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in, foundation filling and mass concrete complete all as directed by Engineer-in-Charge | 2 | CUBIC METRE | |
102 | 102 | Material and labout for masonry thrust block for 90 degree bend of size (30cm x 30cm x 60cm) complete all as directed by Engineer-in-Charge. | 10 | EACH |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy