}

Repair /Replacement And Maintenance Of Connected Items Of Summer Appliances At M House Area Under Ge I Rnd Delhi, Delhi-Delhi

Military Engineer Services-MES has published Repair /Replacement And Maintenance Of Connected Items Of Summer Appliances At M House Area Under Ge I Rnd Delhi. Submission Date for this Tender is 14-03-2020. Air Conditioner Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

23741258
Repair /Replacement And Maintenance Of Connected Items Of Summer Appliances At M House Area Under Ge I Rnd Delhi
Open Tender
Indian
Delhi
Delhi
14-03-2020

Tender Details

Repair /Replacement And Maintenance Of Connected Items Of Summer Appliances At M House Area Under Ge I Rnd Delhi

Key Value

Document Fees
INR 500 /-
EMD
INR 32000.0 /-
Tender Value
INR 16 Lakhs /-

BOQ Items

Name of Work : REPAIR /REPLACEMENT AND MAINTINANCE OF CONNECTED ITEMS OF SUMMER APPLIANCES AT 'M' HOUSE AREA UNDER GE (I) R&D DELHI
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and as directed\n Note:- (i) Any u/s items need to be replaced/gas charging etc shall be measured & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted. 70 Each
2 2 All same as per ser item No. 1.00 above but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton 220 Each
3 3 All same as per ser item No. 1.00 abov but for VRF inverter split type 3 phase ac of capacity 8 TR. 1 Each
4 4 S&F in repair Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC complete all as specified and as directed.\nMake : AUE/FRAGMETER 4 Each
5 5 All same as per ser Item No. 4.00 above but AC (Window/Split Type). 2.0 TR Capacity 2 Each
6 6 S&F for Rewinding of Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity complete all as specified and as directed. 5 Each
7 7 S&F in repair Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceable Air circular Blower Fan Motor complete all as specified and directed. 4 Each
8 8 S&F in repair Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and as directed. 4 Each
9 9 S&F in repair Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity Air complete all as specified and as directed. Make : USHA/UNIVERSAL 10 Each
10 10 S&F in repair Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed. 30 Each
11 11 S&F in repair Capacitor Starting 80 mfd – 120 mfd suitable for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity complete all as specified and as directed. \nMake : USHA/UNIVERSAL 30 Each
12 12 S&F in repair Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity complete all as specified and directed. 10 Each
13 13 S&F in repair Fan Motor Capacitor 4 mfd of suitable for AC (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed. 20 Each
14 14 S&F in repair Fan Capacitor 6 mfd for fan motor suitable for (Window/Split Type) 1.5/2.0TR capacity complete all as specified and directed. 20 Each
15 15 S&F in repair Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity complete all as specified and directed. 2 Each
16 16 S&F in repair front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity complete all as specified and directed. 2 Each
17 17 S&F in repair Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity (As per sample or as per site requirement) complete all as specified and as directed. 5 Each
18 18 S&F in repair Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) complete all as specified and as directed. 4 Each
19 19 S&F in repair Selector Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. 10 Each
20 20 S&F in repair Selector Switch Knob of AC (Window/ Split Type) 1.5 TR/2.0/3.00 TR Capacity complete all as specified and as directed. 10 Each
21 21 S&F in repair Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity Complete all as specified and as directed. 30 Each
22 22 S&F in repair Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. 30 Each
23 23 S&F in repair Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity complete all as specified and as directed. 10 Each
24 24 S&F in repair cooling coil suitable for window type room AC 1.5/2 ton . 2 Each
25 25 S&F in repair Condensing coil suitable for window type AC 1.5/2 ton 2 Each
26 26 S&F in repair Condensing coil suitable for split upto 2 Ton capacity. 2 Each
27 27 S & F in repair cooling coil suitable for split type AC upto 2 ton capacity 2 Each
28 28 S&F in repair indoor unit suitable for 1.5 TR split type AC complete all as specified and directed. 3 Each
29 29 S&F in repair outdoor unit suitable for 1.5 TR split type AC complete all as specified and directed. 3 Each
30 30 S&F in repair Indoor unit suitable for up to 2 TR split type AC complete all as specified and directed. 2 Each
31 31 S&F in repair outdoor unit suitable for up to 2 TR split type AC without compressor complete all as specified and directed. 2 Each
32 32 S&F in repair of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton. 6 Each
33 33 S&F in repair of Hermitacally sealed compressor for split/ window type AC capacity 2.0 Ton. 6 Each
34 34 Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and as directed. MAKE : KIRLOSKAR/EMERSION 7 Each Job
35 35 All same as per Item No. 34.00 above but AC 2.0 TR Capacity (Window/Split Type). 5 Each Job
36 36 S&F in repair PCB with remote for window type AC up to 2 Ton capacity complete all as specified and directed . 4 Each
37 37 S&F in repair PCB with remote for Split type AC 2/3(1.5x2) Ton capacity complete all as specified and directed . 6 Each
38 38 S&F in repair PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity complete all as specified and directed . 12 Each
39 39 S&F in repair Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) all as specified and as directed. 4 Each
40 40 S&F in repair wiring kit suitable for 1.5 to 2.0 ton capacity AC complete all as specified and directed. 30 Each
41 41 S&F in repair gas charging pin valve complete all as specified and directed. 40 Each
42 42 Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed. 6 Each Job
43 43 Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed. 4 Each Job
44 44 Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed. 122 Kg
45 45 All same as per ser item No. 44.00 above but R- 410/32 for split type AC up to 2 TR capacity complete. 122 Kg
46 46 All same as per ser item No 44.00 above but cassatte type AC 4 TR capacity complete. 12 Kg
47 47 All same as per ser item No 44.00 above but VRF unit 8 TR capacity complete. 12 Kg
48 48 S&F in repair of casing of window type AC including complany fitted condensing & cooling coil complete including PCB except compressor complete 4 Each
49 49 S&F in repair of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed. 4 Each
50 50 All same as per ser item No. 49.00 above but 1/2". 4 Each
51 51 S&F in repair compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed. 4 Each
52 52 S&F in repair compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed. 4 Each
53 53 S & F in repair of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. 100 RM
54 54 All same as per ser item No. 53.00 above but size 1/2" 100 RM
55 55 All same as per ser item No. 53.00 above but size 3/8" 100 RM
56 56 All same as per ser item No. 53.00 above but size 5/8" 150 RM
57 57 S&F in repair PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed. 100 RM
58 58 S&F in repair PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed. 100 RM
59 59 S&F in repair of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1/4" to 5/8" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building. 300 RM
60 60 S&F in repair Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. 2 Each
61 61 S&F in repair Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted. 3 Each
62 62 S&F in repair metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed. Make:- L&T/Siemens/Schneider. 25 Each
63 63 S&F in repair metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed. Make:- L&T/Siemens/Schneider. 25 Each
64 64 S&F in repair of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed. Make:- RR Kabel/Finolex/Havells. 90 RM
65 65 S&F in repair of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed. Make : RR KABEL 90 RM
66 66 S&F in repair for submain wiring including PVC casing capping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn through conduit pvc 20mm dia mediam duty with all accessories including 4.0 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and all as specified . 90 RM
67 67 S&F in repair AC stand suitable for out door AC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication including two coat of synthetic enamel paint over a coat of primer and nuts & bolts etc upto six stories building complete all as specified and as directed. 8 Each
68 68 S&F in repair reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and as directed. 4 Each
69 69 Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstall -ing, Testing, connecting the same after replace-ment of defective/burnt Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and as directed. 4 Each
70 70 S&F for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed. 15 Each Job
71 71 Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed. 6 Each Job
72 72 S&F in repair thermostate switch suitalbe for water cooler of any make & size complete all as specified and directed. Make : ReNUTROL or equivalent 2 Each
73 73 S&F in repair starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed. Make : ReNUTROL or equivalent 4 Each
74 74 S&F in repair defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed. 4 Each
75 75 S&F for preparation of old painted surfaces of water cooler upto 150 ltrs by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting. 8 Each Job
76 76 S&F in repair fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed. 3 Each Job
77 77 S&F in repair of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed. 3 Each
78 78 S&F in repair 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed. 10 Each
79 79 S&F in repair condenser coil suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. 2 Each
80 80 S&F in repair steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacity complete all as specifed and directed. 2 Each
81 81 S&F for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule. 65 Each Job
82 82 S&F for painting of desert cooler capacity upto 4000 CUF with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed.\nNote : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting. 65 Each Job
83 83 S&F in repair of desert cooler sub mersible water pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing. Make:- Khaitan, Bajaj, Havells, Crompton 50 Each Job
84 84 S&F in repair desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing. Make:- Khaitan, Bajaj, Havells, Crompton 35 Each Job
85 85 S&F in repair of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as directed (Frame should be in single piece) 4 Sqm
86 86 S&F in repair plug top 3 pin 5 Amps Make : Anchor, Bajaj, Havells 50 Each
87 87 S&F in repair plug top 3 pin 15 Amps Make : Anchor, Bajaj, Havells 30 Each
88 88 S&F in repair motor capacitor 2.5/3.15/4 mfd. 50 Each
89 89 S&F in repair front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 CUF. 15 Each
90 90 S&F in repair of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed 10 Each
91 91 S&F in repair of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed. 40 Each
92 92 S&F in repair of float valve assembly with PTMT ferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 CUF complete all as directed 30 Each
93 93 S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed 65 Each set of three
94 94 S&F in repair of switch piano, flush type single pole, one way, 5 Amp 230 V AC ISI Marked complete all as specifed and directed Make- Kinjal/Cona/Anchor/SSK 50 Each
95 95 S&F in repair of aluminium multi wing Fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specifed and directed 5 Each
96 96 Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same in eixsting position or as directed by engineer-in-charge with eletric connection and testing complete all as specified and directed\nNote : Rewinding shall be measured and paid seperately. 20 Each
97 97 S&F for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed. 50 Each
98 98 S&F for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as directed. 50 Each
99 99 All same as per ser item No 98.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep 20 Each
100 100 All same as per ser item No 98.00 above but for exhaust fan of size 450 mm sweep 10 Each
101 101 All same as per ser item No 98.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep. 2 Each
102 102 All same as per ser item No 98.00 above but for table fan/wall mounted of 400 mm sweep 5 Each
103 103 S&F for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size (Bearing make/size SKF-6201/6202/ or equivalent make) 50 Each
104 104 All same as per ser item No 103.00 above but for xhaust fan any of size/make- SKF 6203/6204 or equivelent make. 10 Each
105 105 S&F in repaor of rubber seal of suitable size for ceiling fan complete all as specified and directed 100 Each
106 106 S&F in repair of gun metal bush suitable for any type/model/size of fans complete all as directed. Make: As per sample 20 Each
107 107 S&F in repair of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed. 50 Each
108 108 S&F for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by spraying after filling cavities with filler and preparation of surface complete including marking MES No etc all as specified & directed. 20 Each
109 109 All same as per ser item No 108.00 above but exhaust fan of size 250/300 mm sweep complete. 22 Each
110 110 All same as per ser item No 108.00 above but for exhaust fan of size 450 mm sweep 10 Each
111 111 S&F in repair of PVC canopy suitable for 1200 /1400 mm sweep ceiling fan complete all as directed 20 Each
112 112 S&F in repair voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase all as specified and as directed. Make:- V-Guard or equivalent. 5 Each
113 113 S&F in repair voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase all as specified and as directed. Make:- V-Guard or equivalent 3 Each
114 114 S&F in repair wall mounted fan 450mm sweep working on AC 240 V,50Hz, single phase all as specified and as directed. Make:- Bajaj, Havells, Anchor, Crompton 5 Each
115 115 S& F in repair Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase all as specified and as directed. Make:- Bajaj, Havells, Anchor, Crompton 5 Each
116 116 S&F in repair exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase all as specified and as directed. \nMake:- Bajaj, Havells, Anchor, Crompton 10 Each
117 117 Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position. 15 Each Job
118 118 All as per ser item No. 117 here-in-before but capacity 50 ltrs complete all as specified and directed. 8 Each
119 119 S&F in repair of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. . 15 Each
120 120 All as per ser item No. 119 here-in-before but capacity 2KW complete all as specified and directed. 10 Each
121 121 S&F in repair of thermostate as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . 24 Each
122 122 S&F in repair Oil Room Heater 2900 Watt Suitable for 11 Fin,weight 18 Kg with fan complete all as specified and as directed.of Havells Model No OFR 11 Fin or equivalent /Bajaj/Morphy. 2 Each
123 123 S&F in repair of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . 20 Each
124 124 S&F in repair of Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . 20 Each Job
125 125 S&F in repair of water connection CP for inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. . 15 set of two
126 126 S&F in repair of body without side panels made out of stainless steel sheet of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare all as directed 4 Each
127 127 S&F in repair of indicator light (Red & green) as existing of capacity 25/50 ltrsof hot appliances complete all as specified & directed 15 Each set of two
128 127.01 Note for ser item No. 1 to 127 :-\n1. The contractor shall provide and deploy sufficient technician with helpers(as directedd by GE / Engineer-in-charge) and contractor's site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints job card & complete the same complaint detailed by JE E/M Engineer-in-charge (with in 48 hrs)\n2. The complaints shall be attended with in 48 hrs. If the complaints is/are not attended /not complited on same day (except repair/ replacement of major items like replacement of compressor, cooling coil, condensing coil and fan motor etc.) recovery will be done as follows \n(a) After 48 Hrs, Rs - 1000.00 Per complaint per day. \nThe decesion of GE on recovery against penalty shall be final and binding and No representation whatsoever shall be entertained. \n3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. \n4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail