Housing Urban and Rular Development Government Departments Closing in 0 days TDR #23718901

Augmentation Of Infrastructure Facilities At Mahakavi Vennikulam Gopalakurup Memorial Govt Polytechnic Vennikulam Pathanamthitta

Issued by Government Departments · Vennikulam Pathanamthitta, Kerala
Tender Value
8.50 Crore
Estimated cost
Bid Submission
12 Mar 2020
0 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Vennikulam Pathanamthitta → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Augmentation Of Infrastructure Facilities At Mahakavi Vennikulam Gopalakurup Memorial Govt Polytechnic Vennikulam Pathanamthitta

BOQ

Name of Work:Augmentation of Infrastructure Facilities at Mahakavi Vennikulam Gopalakurup Memorial Govt. Polytechnic Vennikulam, Pathanamthitta
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
10Laying and Jointing PVC Pipe. HeadingBI01010001010000000000000515BI0100001112
212.6.1 : Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soilBI01010001010000000000000515BI01000011136769.1cum
322.7.1 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rockBI01010001010000000000000515BI0100001114424.571cum
432.7.3 : Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Hard rock (blasting prohibited)BI01010001010000000000000515BI01000011151798.42cum
542.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soilBI01010001010000000000000515BI0100001116292.641cum
652.9.1 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rockBI01010001010000000000000515BI01000011177.512cum
762.9.3 : Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Hard rock (blasting prohibited)BI01010001010000000000000515BI010000111875.043cum
872.25 : Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.BI01010001010000000000000515BI01000011192298.73cum
982.26.1 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soilBI01010001010000000000000515BI01000011202294.29cum
1092.26.2 : Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rockBI01010001010000000000000515BI0100001121894.542cum
11102.31 : Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area clearedBI01010001010000000000000515BI01000011221925sqm
12112.32 : Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.BI01010001010000000000000515BI01000011231176.46sqm
13122.33.1 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 30 cm girth up to and including 60 cm girthBI01010001010000000000000515BI010000112410each
14132.33.2 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyound 60 cm girth up to and including 120 cm girthBI01010001010000000000000515BI010000112513each
15142.33.3 : Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 120 cm girth up to and including 240 cm girthBI01010001010000000000000515BI01000011261each
16154.1.3 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI01000011274.014cum
17164.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)BI01010001010000000000000515BI0100001128283.419cum
18174.2.5 : Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI010000112929.479cum
19184.11 : Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).BI01010001010000000000000515BI0100001130224.916sqm
20194.12 : Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification .BI01010001010000000000000515BI010000113191476.4kg
21204.13 : Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.BI01010001010000000000000515BI0100001132224.916sqm
22215.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concreteBI01010001010000000000000515BI0100001133644.924sqm
23225.9.2 : Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.BI01010001010000000000000515BI01000011341675.4sqm
24235.9.3 : Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platformBI01010001010000000000000515BI01000011352021.77sqm
25245.9.5 : Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantileversBI01010001010000000000000515BI01000011362837.14sqm
26255.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and StrutsBI01010001010000000000000515BI01000011372025.67sqm
27265.9.7 : Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)BI01010001010000000000000515BI0100001138149.802sqm
28275.9.16.1 : Centering and shuttering including strutting, etc. and removal of form for:Edges of slabs and breaks in floors and wallsUnder 20 cm wideBI01010001010000000000000515BI0100001139671.06metre
29285.9.19 : Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edgesBI01010001010000000000000515BI0100001140608sqm
30295.11.1 : Extra additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)BI01010001010000000000000515BI01000011411784.82sqm
31305.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI010000114266596.5kilogram
32315.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or moreBI01010001010000000000000515BI0100001143120431kg
33325.30 : Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections.BI01010001010000000000000515BI0100001144608metre
34336.15 : Extra for providing and placing in position 2 Nos 6 mm dia M.S bars at every third course of half brick masonry.BI01010001010000000000000515BI0100001145304.81sqm
35348.2.2.2 : Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqmBI01010001010000000000000515BI01000011466.3sqm
36358.3.2 : Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite workBI01010001010000000000000515BI0100001147579.9metre
37368.5 : Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.BI01010001010000000000000515BI010000114810each
38378.13.1 : Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye orequivalent.BI01010001010000000000000515BI0100001149225.272sqm
39389.1.1 : Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Second class teak woodBI01010001010000000000000515BI01000011502.203cum
40399.5.1.1 : Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge.Second class teak wood35 mm thick shuttersBI01010001010000000000000515BI010000115156.16sqm
41409.7.1 : Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured), Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick:Second class teak woodBI01010001010000000000000515BI010000115274.88sqm
42419.12 : Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. ( Area of opening for glass panes excluding portion inside rebate shall be measured).BI01010001010000000000000515BI010000115313.5sqm
43429.14 : Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. ( Shutter area to be measured)BI01010001010000000000000515BI010000115493.6sqm
44439.21.1 : Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non- decorative Type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screwsBI01010001010000000000000515BI010000115532.971sqm
45449.53 : Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)BI01010001010000000000000515BI0100001156258each
46459.77 : Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. completeBI01010001010000000000000515BI010000115718no
47469.82 : Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.BI01010001010000000000000515BI010000115824no
48479.84 : Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.BI01010001010000000000000515BI010000115924no
49489.97.3 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:200x10 mmBI01010001010000000000000515BI0100001160121no
50499.97.5 : Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mmBI01010001010000000000000515BI010000116153no
51509.102 : Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.BI01010001010000000000000515BI0100001162373no
52519.103 : Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete.BI01010001010000000000000515BI010000116343each
53529.121 : Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.BI01010001010000000000000515BI010000116496.6metre
54539.122.2 : Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer-in-charge.BI01010001010000000000000515BI010000116530.766sqm
55549.161 : Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontalside & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mmthick GI sheet ( Zinc coating not less than 120gm/m2) suita2ble for mounting 120min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineralwool Insulation having density min 96Kg/m2 . The frame will have a provision ofG.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style ofsize M10 x 80 ) suitable for fixing in the opening along with Factory madeTemplate for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire ratedglazed shutter . The frame shall be finished with a approved fire resistant primeror Powder coating of not less than 30 micron in desired shade as per thedirections of Engineer - in- charge . (Cost of SS ball bearing hinges is excludedBI01010001010000000000000515BI010000116648metre
56559.162 : Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minFire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certifiedas per laboratory approved by Engineer-in-charge, with suitable mounting ondoor frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mmwide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet(zinc coating not less than 120gm/m²) duly filled mineral wool insulation havingdensity min 96 kg/m³ and fixing with necessary stainless steel ball bearing hingesof size 100x89x3mm of approved make, including applying a coat of approvedfire resistant primer or powder coating not less than 30 micron etc all completeas per direction of Engineer-in-charge (panelling to be paid for seperatelyBI01010001010000000000000515BI010000116711.789sqm
57569.164 : Providing and fixing glazing in fire resistant door shutters, fixed panels & partitionsetc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mmfrom the edges and 150 mm c/c , including applying a coat of approved fire resistantprimer/powder coating of not less than 30 micron on G.I. beading, & special ceramictape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-incharge.The glass shall be clear, toughened, interlayered, non-wired fire resistant having11 mm thickness of approved brand with 120 minutes of fire resistance both integrity &radiation control (EW120) and minimum 15 min of insulation (EI15) and having a soundreduction of ?37dB and LT of 86%. Glass shall be compliant to class 2(B)2 category ofImpact Resistance as per EN 12600. The glass should be manufactured in UL & TUVaudited Facility and including UL-EU Certification.The maximum glazing size cannotbe more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report forthe complete system (Glazed Door or Partition) will be considered valid only if it containsthe stamp and signature of the authorized signatory from the glass manufacturer.(Actual glass size is to be measured at site for payments).BI01010001010000000000000515BI01000011682.556sqm
58579.165.1 : Providing and fixing bright /matt finished Stainless Steel handles of approved\nquality & make with necessary screws etc all complete.125 mmBI01010001010000000000000515BI0100001169150no
595810.7 : Providing and fixing ball bearing for rolling shutters.BI01010001010000000000000515BI01000011702no
605910.9 : Extra for providing grilled rolling shutters manufactured out of 8 mm dia M.S. bar instead of laths as per design approved by Engineer -in-Charges, (area of grill to be measured).BI01010001010000000000000515BI01000011713sqm
616010.28 : Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)BI01010001010000000000000515BI0100001172303kg
626111.4 : 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. completeBI01010001010000000000000515BI010000117332.815sqm
636211.6.1 : Cement plaster askirting upto 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement .18 mm thickBI01010001010000000000000515BI01000011746.45sqm
646311.36 : Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.BI01010001010000000000000515BI0100001175438.662sqm
656411.41.2 : Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.BI01010001010000000000000515BI01000011762605.1sqm
666511.46.2 : Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mmBI01010001010000000000000515BI0100001177240.989sqm
676613.1.2 : 12 mm cement plaster of mix:1:6 (1 cement : 6 fine sand).BI01010001010000000000000515BI010000117810165.1sqm
686713.16.1 : 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)BI01010001010000000000000515BI01000011792483.58sqm
696813.21 : Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.BI01010001010000000000000515BI01000011808087.27kg
706913.22 : Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.BI01010001010000000000000515BI0100001181343.446sqm
717013.28.4 : 12 mm thick plain cement mortar bands in cement mortar 1:4 ( 1 cement : 4 fine sand) :Moulded BandBI01010001010000000000000515BI010000118260per meter per cm
727113.43.1 : Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primerBI01010001010000000000000515BI01000011838788.09sqm
737213.45.1 : Finishing walls with textured exterior pint of required shade:New work (Two or more coats applied @ 3.28 ltr/ 10 sqm ) over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqmBI01010001010000000000000515BI010000118462.81sqm
747313.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)BI01010001010000000000000515BI010000118573.394sqm
757413.47.1 : Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)BI01010001010000000000000515BI01000011863952.33sqm
767513.60.1 : Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new workBI01010001010000000000000515BI01000011878788.09sqm
777614.70 : Melamine polishing on wood work ( one or more coat)BI01010001010000000000000515BI0100001188322.492sqm
787715.60 : Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involvedBI01010001010000000000000515BI01000011892127.97cum
797816.69 : Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 ( 1 cement : 3 coarse sand) , including making joints with or without grooves ( thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge ( length of finished kerb edging shall be measured for payment ). ( Precast C.C. kerb stone shall be approved by Engineer-in-Charge)BI01010001010000000000000515BI010000119012.8cum
807916.79 : Providing , laying spreading and compacting graded stone aggregate ( size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant, carriage of mixed material by tipper to site, for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub - base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer - in- Charge.BI01010001010000000000000515BI0100001191100cum
818016.91.1 : Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.BI01010001010000000000000515BI0100001192400sqm
828121.1.1.2 : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)BI01010001010000000000000515BI01000011931312.88kg
838221.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)BI01010001010000000000000515BI01000011941312.88kg
848321.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thicknessBI01010001010000000000000515BI0100001195291.75sqm
858421.15.2 : Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary necessary screws etc. complete.Powder coated minimum thickness 50 micron aluminiumBI01010001010000000000000515BI01000011969no
868522.5 : Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.BI01010001010000000000000515BI0100001197118.44sqm
878622.22A : Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge.BI01010001010000000000000515BI0100001198510.921sqm
888722.23A : Providing & Applying polymer modified, flexible cementatious negative sidewaterproofing coating with elastic waterproofing polymers on interior wall plastersurface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats ofcementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) afterscrapping and properly cleaning the surface to remove pre-existing paint film &loose particles till plaster is visible, complete in all respect as per the direction ofEngineer-in-Charge.BI01010001010000000000000515BI0100001199820.072sqm
898822.26 : Providing and applying of swellable type water stop tape, 19mm x 25mm thick inlinear meter (expansive nature) for construction joints treatment of RCC structuresuch as raft slab, retaining walls, water storage tank and at the junctions of raftslab with the retaining walls etc.. After cleaning the surface, one coat of requiredprimer for swellable water stop tape shall be applied throughout the length of thejoint @3.78 litre per 240 running meter. Over the primed surface swellable typewater stop tape shall be placed. The work shall be carried out all complete as perspecification and the direction of the engineer-in-charge. The product performanceshall carry guarantee for 10 years against any leakage.BI01010001010000000000000515BI0100001200175.42metre
908923.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- chargesBI01010001010000000000000515BI01000012011.125cum
919023.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-ChargeBI01010001010000000000000515BI01000012021.125cum
929123.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.BI01010001010000000000000515BI01000012031.125cum
939250.2.25.1 : Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-chargeBI01010001010000000000000515BI0100001204110.247cum
949350.6.1.4 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc completeBI01010001010000000000000515BI0100001205168.69cum
959450.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc completeBI01010001010000000000000515BI0100001206438.528cum
969550.6.1.6 : Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc completeBI01010001010000000000000515BI0100001207131.69cum
979650.6.3.2 : Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding completeBI01010001010000000000000515BI010000120815.705cum
989760.7.8 : DR with Departmental. Stone - DRY RUBBLE MASONRY _ Dry rubble without concrete levelling course using departmental rubble including packing to compactness to lines and levels, labour charges etc. complete as per direction of Departmental officers at siteBI01010001010000000000000515BI0100001209114.75cum
999860.7.9 : RR with Departmental. Stone - Random rubble masonry using departmental rubble in foundation and plinth including through and bond stone and levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand).BI01010001010000000000000515BI010000121021.75cum
10099od161604/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. All work upto plinth levelBI01010001010000000000000515BI0100001211700.541cum
101100od161605/2019_2020 : Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum.All work above plinth level upto floor V levelBI01010001010000000000000515BI0100001212957.768cum
102101od161606/2019_2020 : Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, slabs,stair cases, etc. including hoisting and setting in position with cement mortar 1:3 ( 1 cement : 3 coarse sand), cost of required centering, shuttering complete.;M25 grade concreteBI01010001010000000000000515BI01000012130.163cum
103102od161609/2019_2020 : Item Shifted to Sub head 14 as item 14.73Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all completeBI01010001010000000000000515BI0100001214113.04kg
104103od161612/2019_2020 : Providing and fixing S.S fan clamp of 16mm dia in RCC slabs, beams including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer-in-Charge at all levels.BI01010001010000000000000515BI0100001215170each
105104od161613/2019_2020 : Providing and laying Antiskid Ceramic floor tiles 300x300x7 mm of Ist quality conforming to IS : 15622 of approved make,shade,and pattern laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc.including cost and conveyance of all materials,labour charges,lead,lift etc, complete as directed by the Engineer-in-Charge at all levels.BI01010001010000000000000515BI0100001216135.7sqm
106105od161616/2019_2020 : Providing anti termite treatment by using chemical concentration as per IS 6313 (part 11) 1981.The chemical is dissolved in water at the rate 1lit/20lit. The treatment is given as pre-constructional anti- termite treatment using chemical emulsion at 5 to 7.5 litres per square meter sand creating a chemical barrier under the column pits wall trenches, basements excavation and plinth area etc. The works are to be guarenteed for a minimum of ten years.BI01010001010000000000000515BI01000012171622.28sqm
107106od161867/2019_2020 : Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying painting with two coats of approved make and colour synthetic enamel paint over two coats of anticorrossive yellow zinc chromate primer.;G.I. pipesBI01010001010000000000000515BI01000012185904kg
108107od164224/2019_2020 : Providing ,hoisting and fixing upto floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, slabs,brackets etc. including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required centering, shuttering and finishing smooth with 6mm thick cement plaster 1:3 (1 Cement : 3 fine sand) on exposed surfaces complete but excluding the cost of reinforcement with design mix cement concrete of M-25 grade conforming to IS 456 or IS 10262.BI01010001010000000000000515BI01000012190.861cum
109108od164225/2019_2020 : Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, etc. including cost and conveyance of all materials, labour, lead,lift etc. complete as directed by Engineer- in-Charge at all levels.In gratings, frames, guard bar, ladders, railings, brackets, gates & similar works.BI01010001010000000000000515BI01000012204287.99kg
110109od164227/2019_2020 : Supplying and fixing C.I. cover with frame for manholes : 600x600 mm square C.I. cover (Heavy duty) the weight of the cover to be not less than 210 kg. Complete all works including cost and conveyance of all materials, all labour charges,lead, lift, sundries, etc., complete. as directed by the Engineer- in-ChargeBI01010001010000000000000515BI01000012217each
111110od164325/2019_2020 : Extra for providing richer mixes at all floor levels.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum).BI01010001010000000000000515BI010000122287.011cum
112111od164347/2019_2020 : Supplying and fixing rolling shutters of approved make,made of required size M.S laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S top cover of required thickness for rolling shutters including two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, including cost and conveyance of all materials, labour charges,lead,lift etc complete as directed by Engineer in Charge at all levels. 80 X 1.25 mm M.S.Laths with 1.25mm thick top coverBI01010001010000000000000515BI01000012237.2sqm
113112od164365/2019_2020 : 15mm cement plaster of mix, 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement 2 kg/sqm( including mixing water proofing material separately )proportion recommended by manufacturer over roof at all heights including cost and conveyance of all materials, labour charges, scaffolding, sundries etc complete as directed by the Engineer in charge at all levels. (water proofing liquid will be paid separately)BI01010001010000000000000515BI01000012242106.86sqm
114113od164374/2019_2020 : Providing and constructing soak pit 2 m x 2 m x 2 m size with honey comb brick work on the sides upto a height of 1.2 m and brick masonry in CM 1:6 for the balance height,providing and filling brick bats graded, upto a height of 1.7 m,providing and laying precast slab over the pit supporting on the brick work, including cost and conveyance of all materials,labour charges, lead, lift, etc. complete as directed by the Engineer-in-charge.BI01010001010000000000000515BI01000012253no
115114od165060/2019_2020 : Solid block masonry using pre cast sold blocks (Factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part 1 of 1979 for Super structure above floor two level upto floor five level for 10 cm thick wall in: Cm 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete.BI01010001010000000000000515BI010000122614.776cum
116115od165276/2019_2020 : Steel work in built up tubular sections YST 310 grade as per IS: 4923 including cutting, hoisting, fixing in position, welded and bolted including special shaped washers etc. complete with electric resistance or induction butt welded tubes including painting with two coats of approved make and colour synthetic enamel paint over two coats of approved make anticorrossive yellow zinc chromate primer, closing all the open ends properly with same material cost and conveyance of all materials, labour, etc., complete as directed by the Engineer-in-Charge at all levels.BI01010001010000000000000515BI010000122733021.4kg
117116od166182/2019_2020 : Providing and fixing of rock anchoring with epoxy based heavy duty injection adhesive of approved make for rebar fixing of diameters upto 40mm at required depth in rock .The system should be made of two soft foils consisting of resin and hardener foil pack.The installation and the setting instructions should be strictly followed as per the manufacturers recommendations. (The above work shall be carried out by an agency having sufficient experience in this field .Only skilled and experienced persons shall be employed for this purpose.) The rate shall include the cost of drilling required dia holes ,filling with approved injection system for anchoring etc as per manufacturers recommendation and as directed by Engineer in charge. For 25 mm Rebar @ 500 mm depthBI01010001010000000000000515BI0100001228312no
118117od174366/2019_2020 : Providing and fixing Gutter ( excluding gutter support) in required width (upto a maximum of 1200mm girth) with plain galvalume colour coated sheet made out of 0.5mm TCT, minimum 300 MPa cold rolled steel with hot dip metallic coating of Aluminium Zinc alloy (Galvalume) 150 gms/sqm,total of both sides, AZ 150 as per ASTM A 792 or AS1397, with polyester colour coating including cost and conveyance of all materials, scaffolding, lead,lift, labour charges, all taxes etc. complete at all levels as directed by Engineer-in-ChargeBI01010001010000000000000515BI0100001229240.9metre
119118od174367/2019_2020 : Double Skin metal Roofing with insulation consisting of profiled colour coated galvalume sheet of approved make as top sheet with following dimensions (approx. 975mm cover width, 28mm crest height at 195mm pitch) made out of 0.50mm TCT (minimum)cold rolled steel of 550Mpa yield strength (minimum) with hot dip metallic coating of minimum 150gm/sqm zinc aluminium alloy coating mass (55% aluminium, 43.5% zinc & 1.5% silicon) total of both sides. The colour shall have a total coating thickness of 35 microns of silicon modified polyester paint system in approved colour comprising of 20 micron exterior coat on top surface and 5 micron reverse coat on back surface over 5 microns primer coat on both surface. The sheet shall be factory cut and supplied in required length to suit site condition and design drawings. The top sheet shall be crest fixed to the GI ‘Z’ sub girt already provided on the bottom sheet with hot dip galvanized imported self-drilling fasteners with integral EPDM washers for perfect sealing . The bottom sheet shall be reverse profiled colour coated galvalume sheet with 975mm cover width, 28mm crest height at 195mm pitch (approx.)made out of 0.50mm TCT cold rolled steel of 550Mpa yield strength with hot dip metallic coating of minimum 150 gm/sqm Zinc Aluminium Alloy coating mass (55% Aluminium, 43.5% Zinc and 1.5% Silicon) total of both sides. The colour coating shall have a total coating thickness of 35 micron silicon modified polyester paint system in approved colour comprising of 20 micron of exterior coat on top surface and 5 micron reverse coat on back surface over 5 micron primer coat on both surface. The bottom sheet shall be fixed directly to the purlin as liner sheet using galvanized imported self drilling and self tapping fasteners with EPDM washers. Rockwool Slabs of 75mm thick having a density of 64kg/cum encased in polythene bag shall be sandwiched between the internal and external sheeting as insulation. The sheet shall be separated with ‘Z’ shaped sub girts of 50 x 50 x 50mm size made out of 1.6mm thick galvanized steel sheets. The sub girts shall be fixed on the bottom sheet and shall be used for supporting the external sheet (top sheet). Rate shall including cost and conveyance of all material,hooks for fall arrester,walkway etc including all accessories, lead, lift, scaffolding, labour charges etc. complete at all levels as directed by Engineer-in -Charge. For roof measurements, area shall be measured as laid from roof edge to edge of expanse of roof. No deduction shall be made for openings after installation. (The above work is to be carried out by a specialized agency having experience in the laying of this type of roofing system ,approved by the Engineer-in-Charge .)BI01010001010000000000000515BI01000012301500.97sqm
120119Water Supply\n17.2.1 : Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lidBI01010001010000000000000515BI010000123117each
12112017.31 : Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.BI01010001010000000000000515BI010000123210each
12212118.7.2 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal outer dia pipesBI01010001010000000000000515BI01000012336metre
12312218.7.3 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall25 mm nominal outer dia pipesBI01010001010000000000000515BI01000012346metre
12412318.7.4 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall32 mm nominal outer dia pipesBI01010001010000000000000515BI010000123518metre
12512418.7.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall40 mm nominal outer dia pipesBI01010001010000000000000515BI010000123636metre
12612518.7.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall50 mm nominal outer dia pipesBI01010001010000000000000515BI010000123784metre
12712618.9.5 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work40 mm nominal outer dia pipesBI01010001010000000000000515BI010000123812metre
12812718.9.6 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work50 mm nominal outer dia pipesBI01010001010000000000000515BI0100001239120metre
12912818.9.7 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer- in-Charge. External work62.50 mm nominal inner dia pipesBI01010001010000000000000515BI010000124012metre
13012918.17.1 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal boreBI01010001010000000000000515BI010000124110each
13113018.17.1A : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :20 mm nominal boreBI01010001010000000000000515BI01000012425no
13213118.17.2 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal boreBI01010001010000000000000515BI010000124310each
13313218.17.3 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal boreBI01010001010000000000000515BI01000012445each
13413318.17.4 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal boreBI01010001010000000000000515BI01000012455each
13513418.17.5 : Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal boreBI01010001010000000000000515BI01000012462each
13613518.19.3.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):40 mm nominal boreHorizontalBI01010001010000000000000515BI01000012472each
13713618.19.4.1 : Providing and fixing gun metal non-return valve of approved quality (screwed end):50 mm nominal boreHorizontalBI01010001010000000000000515BI01000012486each
13813718.33.1 : Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5BI01010001010000000000000515BI010000124910each
13913818.48 : Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.BI01010001010000000000000515BI010000125010000Litre
14013919.7.1.1 : Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weigh of cover 23 kg and weight of frame 15 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5BI01010001010000000000000515BI01000012518each
14114019.8.1.1 : Extra for depth for manholesSize 90x80 cmWith common burnt clay F.P.S. ( non modular ) bricks of class designation 7.5BI01010001010000000000000515BI01000012521metre
14214123.5 : Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer -in- chargesBI01010001010000000000000515BI01000012530.5cum
14314223.6 : Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit,over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer -in-ChargeBI01010001010000000000000515BI01000012540.5cum
14414323.7 : Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.BI01010001010000000000000515BI01000012550.5cum
14514450.17.1.5 : Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.BI01010001010000000000000515BI010000125618no
14614550.18.8.2.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2BI01010001010000000000000515BI010000125798metre
14714650.18.8.3.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 10kgf /cm2BI01010001010000000000000515BI0100001258197metre
14814750.18.8.4.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2BI01010001010000000000000515BI010000125930metre
14914850.18.8.5.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2BI01010001010000000000000515BI010000126018metre
15014950.18.8.6.2 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 6 kgf/cm2BI01010001010000000000000515BI010000126145metre
15115050.18.8.8.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 75 mm pipe 6 Kgf/cm2BI01010001010000000000000515BI010000126260metre
15215150.18.8.9.1 : Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2BI01010001010000000000000515BI010000126366metre
15315250.18.9.8.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 6 Kgf/ cm2BI01010001010000000000000515BI010000126430metre
15415350.18.9.9.1 : Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2BI01010001010000000000000515BI0100001265120metre
15515450.18.9.18.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wallBI01010001010000000000000515BI010000126630metre
15615550.18.9.18.2 : Providing and fixing PVC pipes including fixing the pipe with clamps/Clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 4 Kfg/cm2 - External work - Exposed on wallBI01010001010000000000000515BI010000126730metre
15715650.18.9.19.1 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wallBI01010001010000000000000515BI0100001268217metre
158157od162745/2019_2020 : Providing and fixing vitreous china under counter wash basin of approved make including one CP brass pillar cock 15 mm NB including connecting pipes with all fittings 32 mm dia rubber plugs 32 mm dia CP brass waste coupling, 32 mm dia CP brass bottle trap,CP brass 15mm angle valve,complete including CI/MS brackets duly painted, nuts, washers, etc. complete,cost and conveyance of all materials labour charges ,lead, lift necessary wall cutting / chasing and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels.BI01010001010000000000000515BI010000126911each
159158od162746/2019_2020 : Providing & fixing star white vitreous china flat back urinal with CP brass flush valve auto closing system with built in control cock and wall flange of approved size with all accessories to provide satisfactory functioning including cost and conveyance of all materials, labour charges ,lead, lift necessary wall cutting / chasing and making good the walls,floors,slab, as required for urinal flushing etc complete, testing and commissioning to the satisfaction of Engineer in charge at all levels.BI01010001010000000000000515BI01000012707each
160159od162747/2019_2020 : Providing and fixing of star white vitreous china urinal division plate of approved quality and make with fittings/fastener including cutting and making good the walls,floors,slab ,cost and conveyance of all material, labour charge, lead, lift, all taxes etc. complete as directed by the Engineer in charge at all levels.BI01010001010000000000000515BI01000012717each
161160od162748/2019_2020 : Providing and fixing CP brass body bib cock etc. complete including cost and conveyance of all materials labour charges ,lead, lift,including cutting and making good the walls,floors,slab,testing and commissioning to the satisfaction of Engineer in charge at all levels.BI01010001010000000000000515BI010000127218no
162161od162749/2019_2020 : Providing and fixing C.P. brass concealed stop cock (control valve) of standard design and of approved make conforming to IS:8931 etc. including cost and conveyance of all materials, labour charges, lead,lift, necessary wall cutting / chasing and making good the walls,floor,slab etc complete, testing and commissioning to the satisfaction of Engineer in charge at all levels.BI01010001010000000000000515BI01000012733no
163162od162750/2019_2020 : Providing and fixing floor trap with cockroach trap (multi trap), concealed , SS304 grade floor grating with cup inclu ding cost and conveyance of all materials, labour charges, sundries etc complete as directed by the directed by the Engineer in Charge at all levelsBI01010001010000000000000515BI010000127420each
164163od162751/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.75mm diaBI01010001010000000000000515BI01000012758each
165164od162752/2019_2020 : Providing and fixing Cleanout with Spigot, with SS 304 Square Frame & Round Frame with Flat Round Cover with Rubber Seal & SS Screw including cost and conveyance of all materials, labour charges, sundries etc complete as directed by the Engineer in charge at all levels.110 mm diaBI01010001010000000000000515BI01000012768each
166165od162756/2019_2020 : Providing and fixing C.I. grating 150x150 mm as directed by the Engineer-in-chargeBI01010001010000000000000515BI010000127718each
167166od162757/2019_2020 : Providing and fixing 110mm dia PVC vent cowl to pipe already fixed as directed by Engineer-in-charge at all levels. 110mm diaBI01010001010000000000000515BI01000012782each
168167od162760/2019_2020 : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall 65 mm nominal outer dia pipesBI01010001010000000000000515BI01000012796metre
169168od162761/2019_2020 : Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 160 mm dia 6 Kgf/cm2 - External work- Exposed on wallBI01010001010000000000000515BI01000012806metre
170169od162762/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 40 mmBI01010001010000000000000515BI01000012812each
171170od162763/2019_2020 : Supplying and fixing GM foot valve with all accessories including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer -in - charge at all levels. 50 mmBI01010001010000000000000515BI01000012826each
172171od162764/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mmBI01010001010000000000000515BI01000012835no
173172od162765/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 80mmBI01010001010000000000000515BI01000012845no
174173od162767/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mmBI01010001010000000000000515BI01000012852no
175174od162768/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mmBI01010001010000000000000515BI01000012865no
176175od162769/2019_2020 : Providing and fixing 75mm dia PVC vent cowl to pipe already fixed as directed by Engineer-in-charge at all levels. 75mm diaBI01010001010000000000000515BI01000012874each
177176od162770/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 50mm Y type strainerBI01010001010000000000000515BI01000012887no
178177od162771/2019_2020 : Providing and fixing CI Y type strainer rating PN 10 complete with SS 304 filter screen of 1mm Perforation X 24G flanged and connection, flanges etc.including cost and conveyance of all materials,labour etc. complete and as directed by Engineer-in-Charge 40mm Y type strainerBI01010001010000000000000515BI01000012892no
179178od162774/2019_2020 : Supplying approved make PVC gully trap of size 160 x 110mm and CI grating 150mmx150mm size and light duty C.I cover with frames 300mmx300mm size(inside) the weight of cover to be not less than4.5kg and frame to be not less than2.7kg (CI MH cover and frame as per IS:1726) single sealed of size conveying to size the above mentioned items and constructing 30cmx30cm internal size gully trap chamber and depth upto 60cm,115 thk brick wall in CM 1:6 on a foundation of PCC 1:4:8.100mm thick plastering inside with CM 1:3,12mm thk with a neat cement flushing coat and conveying to site,cleaning ,installing and testing approved make PVC gully trap with 160mm outlet(Fabricated),surrounding with CC 1:1.5:3, 150x150mmm,top with CI grating above the PVC gulley trap and light duty CI cover and frame over the chamber including cost of all materials, etc complete as per approved drawing and as directed by Engineer-in- Charge.BI01010001010000000000000515BI01000012902each
180179od162775/2019_2020 : Providing and fixing light duty Cast Iron Manhole covers including cost and conveyance of all materials,labour charges,lead,lift etc complete as directed by Engineer in Charge. 600x600mmBI01010001010000000000000515BI01000012913each
181180od162784/2019_2020 : Providing and fixing enclosed type water meter (bulk type) conforming to IS: 2373 and tested by Municipal Board complete with bolts, nuts, rubber fittings etc. ( The tail pieces if required will be paid separately): 50 mm dia nominal boreBI01010001010000000000000515BI01000012921each
182181od162785/2019_2020 : od37131/2018_2019 :Supplying and fixing of centrifugal pump, with CI construction, CI impeller, mechanical seal, complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels Capacity: 10 m3/hr Head: 30 mBI01010001010000000000000515BI01000012934no
183182od162786/2019_2020 : >Supplying and fixing of centrifugal pump, with CI construction, CI impeller complete with motor, base plate, foundation bolts, nuts,pressure guage and all accessories. and working with 415V, 3ph and 50 Hz frequency including cost and conveyance of all materials,labour charges etc complete as directed by the Engineer in charge at all levels >Head 35m, Capacity-5 m3/hrBI01010001010000000000000515BI01000012942no
184183od162900/2019_2020 : Providing and fixing CP robe hook etc complete testing and commissioning to the satisfaction of Engineer in Charge at all levels.Models: (Jaquar ACN 1161N or equivalent)BI01010001010000000000000515BI010000129518each
185184od162901/2019_2020 : Providing and fixing concealed floor trap including SS cockroach free floor grating with cup etc. complete, testing and commissioning to the satisfaction of Engineer in Charge at all levels.BI01010001010000000000000515BI01000012963each
186185od162946/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 150mmBI01010001010000000000000515BI01000012975no
187186od162947/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mmBI01010001010000000000000515BI01000012982no
188187od162948/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 200mmBI01010001010000000000000515BI01000012992no
189188od162949/2019_2020 : Supplying and fixing of CI double flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 100mmBI01010001010000000000000515BI01000013005no
190189od162950/2019_2020 : Supplying and fixing of CI single flanged wall casting pipe with puddle, 0.6m length including cost and conveyance of all materials,labour charges,making good the walls etc complete as directed by the Engineer in Charge. 65mmBI01010001010000000000000515BI01000013015no
191190od163005/2019_2020 : Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2BI01010001010000000000000515BI0100001302420RM
192191od163006/2019_2020 : Providing and laying non-pressure NP4 class (heavy duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement : 2 fine sand) including testing of joints etc. complete: 300 mm dia R.C.C. pipeBI01010001010000000000000515BI010000130310metre
193192od163007/2019_2020 : Supplying and fixing of chlorine dosing system of capacity0-6LPH with tank size 100L complete as directed by the engineer in chargeBI01010001010000000000000515BI01000013041no
194193od163008/2019_2020 : >Supplying and fixing of activated carbon filter of 800 mm dia x 1500 mm height, comprising of: Vertical ,welded mild steel pressure vessel complete with dished ends and internally coated with epoxy paint. The vessel complete with manhole and cover shall be painted externally with bituminous paint. Rate to be inclusive of set of internals for the above comprising of raw water distributor and filter water collecting system, set of frontal pipe work of mild steel construction complete with vent piping, set of mutually operated multiport valves, set of inlet and outlet pressure guages, etc complete including cost and conveyance of all materials,labour charges,lead ,lift etc as directed by the Engineer in charge at all levels Capacity:5 m3/hour Head:35mBI01010001010000000000000515BI01000013051no
195194od163009/2019_2020 : Supplying and fixing of pressure sand filter of 600 mm dia x 1200 mm height,comprising of Vertical ,welded mild steel pressure vessel complete with dished ends and internally coated with epoxy paint. The vessel complete with manhole and cover painted externally with bituminous paint. Rate inclusive of set of mutually operated multiport valves, set of internals for the above comprising of raw water distributor and filter water collecting system, set of frontal pipe work of MS construction complete with vent piping, set of inlet and outlet pressure guages, set of inlet and outlet sample valves etc complete including cost and conveyance of all materials,labour charges,lead, lift etc as directed by the Engineer in charge at all levels.Capacity- 5 m3/hrHead- 35 mBI01010001010000000000000515BI01000013061no
196195od164840/2019_2020 : Providing and fixing sanitary fixtures for handicaped toilet including one wash basin , one pair mounting brackets,one number pillar cock & all other related fittings like bottle trap ,angle cock,waste coupling, etc,one number EWC & Cistern complete with fittings & seat cover, one no. hinged rail 76cm & 4nos. of grab rails 60cm etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge.BI01010001010000000000000515BI01000013071each
197196od164843/2019_2020 : Providing and fixing CI vent cowl as directed by the Engineer in Charge at all levels 80 mm diaBI01010001010000000000000515BI01000013085no
198197ELECTRICAL\n1.7.1 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wireBI01010001010000000000000515BI01000013092930metre
1991981.7.2 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2X2.5 sq.mm+1X2.5 sq.mm earth wireBI01010001010000000000000515BI01000013101649metre
2001991.7.3 : Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2x4 sq.mm + 1x4 sq.mm earth wireBI01010001010000000000000515BI0100001311544metre
2012001.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group CBI01010001010000000000000515BI0100001312496point
2022011.11 : Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.BI01010001010000000000000515BI010000131310point
2032021.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mmBI01010001010000000000000515BI010000131410metre
2042031.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mmBI01010001010000000000000515BI0100001315140metre
2052041.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mmBI01010001010000000000000515BI010000131660metre
2062051.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mmBI01010001010000000000000515BI010000131760metre
2072061.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mmBI01010001010000000000000515BI010000131850metre
2082071.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mmBI01010001010000000000000515BI010000131920metre
2092081.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switchBI01010001010000000000000515BI010000132018each
2102091.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outletBI01010001010000000000000515BI010000132118each
2112101.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outletBI01010001010000000000000515BI010000132221each
2122111.24.7 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outletBI01010001010000000000000515BI01000013236each
2132121.24.8 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell pushBI01010001010000000000000515BI010000132411each
2142131.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.BI01010001010000000000000515BI0100001325187each
2152141.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.BI01010001010000000000000515BI010000132610each
2162151.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)BI01010001010000000000000515BI0100001327294each
2172161.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings).BI01010001010000000000000515BI010000132875each
2182171.32 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.BI01010001010000000000000515BI010000132913each
2192181.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.BI01010001010000000000000515BI010000133011each
2202191.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.BI01010001010000000000000515BI0100001331320each
2212201.45 : Installation, testing and commissioning of ceiling fan, including wiring the down rods of standardlength (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable,including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.BI01010001010000000000000515BI0100001332187no
2222211.49 : Numbering of ceiling fan / exhaust fan/ fluorescent fittings as required.BI01010001010000000000000515BI0100001333665each
2232221.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweepBI01010001010000000000000515BI010000133419each
2242231.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group CBI01010001010000000000000515BI0100001335170point
2252242.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double doorBI01010001010000000000000515BI01000013365each
2262252.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single poleBI01010001010000000000000515BI0100001337200each
2272262.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple poleBI01010001010000000000000515BI010000133815each
2282272.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.BI01010001010000000000000515BI010000133915each
2292287.1.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Upto 35 sq. mmBI01010001010000000000000515BI0100001340300metre
2302297.1.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size direct in ground including excavation, sand cushioning, protective covering and\nrefilling the trench etc as required.Above 95 sq. mm and upto 185 sq. mmBI01010001010000000000000515BI010000134148metre
2312307.2.1 : Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size direct in ground in the same trench in one tier horizontal formation\nincluding excavation, sand cushioning, protective covering and refilling the trench etc as\nrequired.Upto 35 sq. mmBI01010001010000000000000515BI010000134224metre
2322317.5.1 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mmBI01010001010000000000000515BI010000134312metre
2332327.5.3 : Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of\nfollowing size in the existing RCC/ HUME/ METAL pipe as required.Above 95 sq. mm and upto 185 sq. mmBI01010001010000000000000515BI010000134412metre
2342337.7.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)BI01010001010000000000000515BI0100001345336metre
2352347.7.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)BI01010001010000000000000515BI01000013466metre
2362357.7.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on wall surface as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)BI01010001010000000000000515BI01000013476metre
2372367.8.1 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Upto 35 sq. mm (clamped with 1mm thick saddle)BI01010001010000000000000515BI0100001348342metre
2382377.8.2 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)BI01010001010000000000000515BI01000013496metre
2392387.8.3 : Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV\ngrade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)BI01010001010000000000000515BI01000013506metre
2402399.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 70 sq. mm (38mm)BI01010001010000000000000515BI01000013512set
2412409.1.27 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.3 1/2X 185 sq. mm (57mm)BI01010001010000000000000515BI01000013522set
2422419.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 16 sq. mm (28mm)BI01010001010000000000000515BI010000135310set
2432429.1.35 : Supplying and making end termination with brass compression gland and aluminium lugs for \nfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV \ngrade as required.4 X 35 sq. mm (32mm)BI01010001010000000000000515BI01000013542set
24424314.14.1 : Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with\nRCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.100 mm diaBI01010001010000000000000515BI010000135515metre
245244od161938/2019_2020 : Supply and fixing of 4 pole 40 amps. (415 Volts), 100mA sensitivity residual current circuit breaker with MCB having earth leakage and overload protection (RCBO) as per specification as requiredBI01010001010000000000000515BI01000013561no
246245od161939/2019_2020 : Providing and fixing following 25x3 size copper strip on surface or in recess for loop earthing as required.BI01010001010000000000000515BI010000135730metre
247246od161940/2019_2020 : MSB Supply, installation, testing and commissioning of LT Switch Board (Main Panel), cubicle type, made out of 2mm thick CRCA sheet,totally enclosed, IP 42, wall / floor mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase , 415 V, 50Hz AC system with busbars , including internal wiring with suitable size HFFR wires/cable, interconnection, duly powder coated with seven tank process etc.The panel shall be fabricated from a firm having CPRI certification with test certificates for similar panel (required for short circuit rating, temperature rise and IP classification) and with following switchgears, metering instruments and accessories etc. complete as required as per drawing specification. The Panel shall be of Form 4b Construction. Instruments RYB Indicating lamps LED type -As per SLD 4A SP MCB-As per SLD (0-500)V Class 1 with 90 deg defl. Scale-As per SLD (0-200)A Class 1 with 90 deg defl. Scale -As per SLD (0-100)A Class 1 with 90 deg defl. Scale -As per SLD Voltmeter selector switch -As per SLD 100/5 A 5 VA Class 1 CTs -As per SLD 200/5 A 5 VA Class 1 CTs -As per SLD ON/OFF/TRIP INDICATION LAMP -As per SLD ON/OFF INDICATION LAMP -As per SLD Digital multifunction meter to read V,A.Hz,PF,Kwh- As per SLD surge protection device (type1+2)-As per SLD Incomer 160A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 No 100A FP Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 No 200A TPN busbar chamber with Aluminium busbar 160A FP BUS COUPLER(with Electrical and mechanical interlock facility) Out goings 100A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 No 63A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -1 No 40A TP+NL Moulded Case Circuit Breaker with thermal release with OL and SC protection neutral link (Ics =100%Icu= 25kA) -5 Nos 63A FP MCCB ISOLATOR-1No The panel shall be Top Entry/Exit and suitable for termination of cable system as per SLD and technical specificationBI01010001010000000000000515BI01000013581no
248247od161941/2019_2020 : Supply of IP66 streetlight luminaire made of die cast aluminium along with driver,system wattage of 30+/-2 Watts,lumen output of luminaire greater than 3000 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 95 lumen/watt ,wth suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Wipro LR02- 331-XXX-57-XX or other approved equivalent makes)BI01010001010000000000000515BI010000135915no
249248od161942/2019_2020 : Supplying and laying 25x3 Copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.BI01010001010000000000000515BI010000136015metre
250249od161945/2019_2020 : 50 KVA DG SET Supply, Installation, Testing and Commissioning of 50 KVA prime rated D.G Set with acoustic enclosure and Control panel ,protection and digital metering,controls and interlocks, CTs and transducers for all metering and protection and suitable FP MCCB etc. , including antivibration mountings, exhaust silencer and exhaust pipe conforming to latest environment protection regulations for emission and noise levels complete with , water/ coolant cooled, (radiator type) four stroke, electric start conforming to BS: 5514 50 KVA prime rating, brushless, self excited, self regulated and suitable for continuous operation at 1500rpm, generating 415 V+/-5% Volts at 0.8 p.f (lag), 50Hz,3 phase, 4 wire system generally conforming to BS: 2613 IS: 4722. Both Engine and Alternator shall be mounted on common channel iron base frame, and with standard accessories such as lead acid batteries and engine driven battery charger along with leads,battery stand, necessary control wiring with control cables, first fill of lubricating oil, and earthing as per standards Fuel tank for 8 hours suitable continous operation, fuel piping from fuel tank to Engine, Residential silencer, suitable size Cable termination box with extended Alternator terminal with bus bars etc as required and as per specifications.Rate shall be exclusive of all the civil work including RCC foundation .The work should be as per Electrical Inspectorate/ Central Pollution control board standards applicable at the time of delivery.BI01010001010000000000000515BI01000013611no
251250od161946/2019_2020 : Supply of following 4C 35 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI010000136272metre
252251od161947/2019_2020 : Supply and fixing of following 2 pole 25 amps. (415 Volts),30mA sensitivity. rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredBI01010001010000000000000515BI01000013635no
253252od161948/2019_2020 : 10 KVA UPS Supply, Installation, Testing and Commissioning of 10 kVA, Three phase input, Three Phase output, true on-line UPS System with 30 minutes back up , output isolation transformer,including all accessories, SMF batteries VRLA type with powder coated CRCA cabinet including all accessories such as output panel required for ups parellel operation, cabling etc as required complete having following specification.The UPS system consist of one numbers of UPS unit and one set of battery bank . The UPS shall be suitable for parellel operation. RS485 Interface compatibility Fully digital controlled based on DSP Power factor corrected from end > 0.9 Pure sine wave output. Full time output voltage frequency regulation Auto regulation of battery end voltage Intelligent interface with LED/LCD display Static bypass switch / manual by pass switch Auto temperature compensation, Remote Management Interphase, Back up time 30 minutes at full loadBI01010001010000000000000515BI01000013641no
254253od161949/2019_2020 : Supply of 3C 10 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI010000136518metre
255254od161950/2019_2020 : Providing and fixing 25mm X 6mm GI strip/wire on surface or in recess for connections etc. as required.BI01010001010000000000000515BI010000136678metre
256255od161952/2019_2020 : Supply of 3C 4 Sq.mm Cu1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI0100001367108metre
257256od161953/2019_2020 : Supplying and laying 10 SWG Cu. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ terminationBI01010001010000000000000515BI010000136875metre
258257od161954/2019_2020 : Supply of outdoor BULKHEAD luminaire made of polycarbonate housing along with driver,system wattage of 10+/-2 Watts,lumen output of luminaire greater than 700 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours system efficacy greater than 70 lumen/watt ,with suitable driver and including all necessary accessories as required complete.(Make:- Cat No: Crompton -LBHP -10-CDL or other approved equivalent makes)BI01010001010000000000000515BI01000013696no
259258od161955/2019_2020 : Supply of following 4C 2.5Sq.mm Cu size 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI0100001370114metre
260259od161956/2019_2020 : Supply and fixing outdoor type START/STOP (2way) push button station (IP65) including all the necessary accessories as required complete with suitable mounting arrangement.(Cat No Hensel-PBS 0201 or equivalent approved make)BI01010001010000000000000515BI01000013717no
261260od161957/2019_2020 : Supplying and laying 25 mm X 6 mm G.l strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt,spring, washer etc. as required.BI01010001010000000000000515BI010000137254metre
262261od161958/2019_2020 : Supply installation, testing and commissioning of FASD starter in sheet steel enclosure for 15 HP , 3 PHASE motor including auxilliary contactors, capacitor , and all necessary accessories as required complete.BI01010001010000000000000515BI01000013731no
263262od161959/2019_2020 : Supplying and making end termination with brass compression gland and Cu lugs for following 4Cx2.5 sqmm size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI010000137412no
264263od161960/2019_2020 : Supply of surface mounted LED panel light fixture light made of CRCA along with driver,system wattage of 33 +/- 3 Watts with lumen output of luminaire greater than or equal to 3600 lumens, power factor > 0.9, rated life of L70 @ 50,000 hours, system efficacy greater than or equal to 100 lumen/watt and including all necessary accessories as required complete.Make:- Cat No: Crompton POLARIS NIO III or equivalent one)BI01010001010000000000000515BI010000137512no
265264od161962/2019_2020 : Supply of 2C 6 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI0100001376108metre
266265od161964/2019_2020 : Supply of 4C 16 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI0100001377390metre
267266od161965/2019_2020 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.> Triple PoleBI01010001010000000000000515BI01000013784no
268267od161966/2019_2020 : Supply, fixing of Network point, UTP RJ45, CAT 6 modular type socket with modular plate cover on surface or in recess, including proving and fixing suitable size GI box, inter connection etc as required complete.BI01010001010000000000000515BI010000137950no
269268od161967/2019_2020 : Supply of following sizes of 1200 mm sweep ceiling fan, with double ball bearing, Aluminium pressure die cast body with Aluminium blades, canopies, hanging shackle, 30 cm down rod and without speed regulator suitable for 240V 50 HZ, AC supply confirms to IS 374/1979 as required complete. (Make crompton-High breeze or equivalent approved make).BI01010001010000000000000515BI0100001380187no
270269od161968/2019_2020 : Providing and fixing 3.15mm Cu (10 SWG) Cu wire on surface or in recess for connections etc. as required.BI01010001010000000000000515BI0100001381244metre
271270od161969/2019_2020 : Supply of 250 mm sweep,900 rpm light duty exhaust fan in plastic body with self opening louvers working on 230 V AC supply complete with all accessories as required. (Make: Orient Smart Air Exhaust or equivalant approved make)BI01010001010000000000000515BI010000138219no
272271od161970/2019_2020 : Supply fixing Computer points with 3 nos 3 pin 5/6A socket with 2no.5/6A switch with modular front plate and cover on surface/recess, including proving and fixing suitable size GI boxs, its interconnections etc as required complete. (Note: 2 nos 5/6A socket fixed at 60cm above FFL and 2 nos 6A switch with 1no 5/6A socket at 1m above FFL)BI01010001010000000000000515BI010000138350no
273272od161971/2019_2020 : Earthing with C.I. earth pipe 4 metre long, 100 mm dia including accessories, and providing masonry enclosure with heavy duty CI cover plate of 300X300mm having locking arrangement and watering pipe etc. with 64kg charcoal/ coke and 5kg salt as required. (As per IS 3043 ammended uptodate)BI01010001010000000000000515BI01000013845no
274273od161973/2019_2020 : Supplying and fixing of following 4way (8 + 12), Double door ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)BI01010001010000000000000515BI01000013852no
275274od161974/2019_2020 : Installation, testing and commissioning of High bay/Mid bay/LED/ FLOOD type fittings on wall/Column/truss/false ceiling using suitable MS clamps, nuts, bolts/ 20mm heavy duty GI chain/ pipe (upto 50cm)etc including connections with 3C 2.5 Sq.mm PVC insulated flexible copper conductor cable as required.BI01010001010000000000000515BI010000138615no
276275od161975/2019_2020 : Supplying and fixing of following 8 way (8 + 24), Double door ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)BI01010001010000000000000515BI01000013871no
277276od161976/2019_2020 : Installation, testing and commissioning of LED fittings with chain and copper wiring, complete with all accessories on false ceiling including supplying and fixing of GI chain and hook arrangement, upto 60cm length, and wiring using 3 runs of 1.5 sqmm FRLS PVC insulated stranded copper conductor cable as required.BI01010001010000000000000515BI0100001388136no
278277od161977/2019_2020 : Supplying and making end termination with brass compression gland and Copper lugs for 4C 10 Sq.mm Cu XLPE insulated PVC sheathed Cu conductor cable of 1.1 kV grade as required.BI01010001010000000000000515BI01000013896no
279278od161978/2019_2020 : Supplying and fixing following 8 way (8 + 24), Double door way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)BI01010001010000000000000515BI01000013906no
280279od161980/2019_2020 : Supplying and fixing following 6 way (8 + 18), Double door way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)BI01010001010000000000000515BI01000013912no
281280od161981/2019_2020 : Supplying and making end termination with brass compression gland and copper lugs for following 3C 4 Sq.mm Cu size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI010000139224no
282281od161982/2019_2020 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.> Four PoleBI01010001010000000000000515BI01000013931no
283282od161983/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following 3C 10 sqmm Al size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI01000013944no
284283od161984/2019_2020 : Supply, Installation, Testing Commissioning of 40 A FP isolator in 1.6mm thick sheet steel enclosure duly painted with powder coated finishing on surface including all the mounting accessories, internal wiring etc as required complete.BI01010001010000000000000515BI01000013953no
285284od161985/2019_2020 : Supplying and making end termination with brass compression gland and aluminum lugs for following 4C 6 Sq.mm Al size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI010000139614no
286285od161986/2019_2020 : Supply and fixing of following 4 pole 40 amps. (415 Volts), 100mA sensitivity. rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredBI01010001010000000000000515BI01000013971no
287286od161988/2019_2020 : Supply of 4C 10 Sq.mm Cu 1.1 KV grade XLPE insulated, PVC sheathed, armoured copper conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI010000139830metre
288287od161989/2019_2020 : Supply of 4C 6 Sq.mm Al 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium /copper conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI0100001399186metre
289288od161990/2019_2020 : Supply and fixing of following 6A to 32A, SP,D-CURVE rating, 10 KA, Miniature Circuit Breakers as required.BI01010001010000000000000515BI010000140048no
290289od161991/2019_2020 : Supplying and making end termination with brass compression gland and aluminium lugs for following 2C 6 sqmm Al size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI01000014018no
291290od161992/2019_2020 : Supplying and installing following 150 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts nuts, etc. as required.BI01010001010000000000000515BI010000140260metre
292291od161993/2019_2020 : Supplying and installing following 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts nuts, etc. as required.BI01010001010000000000000515BI010000140310metre
293292od161994/2019_2020 : Supply, fabricating and installing MS items such as Tees/ angles/ channels etc. on floor/ ceiling/ wall including necessary civil work such as grouting, finishing etc. and painting with two coats of primer and two coats of synthetic enamel paint as requiredBI01010001010000000000000515BI0100001404100kg
294293od162289/2019_2020 : Supply of 2x2 LED recess mounted fixture with housing made of CRCA body and a high efficiency diffuser along with driver, system wattage 36 Watts, cool white fixture (CCT-5700) lumen output of luminaire greater than or equal to 3600 lumens, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than or equal to 100 lumen/watt ,with suitable driver and including all necessary accessories as required complete.Make:- Cat No: LT Crompton POLARIS NIO -1 or equivalent approvedBI01010001010000000000000515BI0100001405136no
295294od162544/2019_2020 : Supply of following 3.5C 70 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI010000140612metre
296295od162545/2019_2020 : Supply of 450 mm size wall mounting oscillating type fan having three speed control, oscillation control at bottom and suitable for operation on single phase 230 volt, 50Hz AC supply complete with continuous duty motor, chrome plated front and rear gaurds and all accessories as required complete.(Make: CG Vortex air circulator 450mm or equivalent approved make).BI01010001010000000000000515BI01000014073no
297296od162546/2019_2020 : Installation, testing and commissioning of Wall fan, including all the supports as required and wiring using 3 runs of 1.5 sqmm FR PVC insulated stranded copper conductor etc complete.BI01010001010000000000000515BI01000014083no
298297od162604/2019_2020 : Supplying and fixing following 8 way surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of 125/160 amps TP 16/25 kA MCCB as incomer, interconnection between incomer MCCB and bus bars (but without MCB’s/ MCCB) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)BI01010001010000000000000515BI01000014091no
299298od162605/2019_2020 : Supply and fixing of following 4 pole 25 amps. (415 Volts),100mA sensitivity. rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredBI01010001010000000000000515BI01000014102no
300299od162606/2019_2020 : Supply and fixing of following 4 pole 40 amps. (415 Volts),30mA sensitivity. rating residual current circuit breaker with MCB having earth leakage and overload protection (RCCB+MCB) as per specification as requiredBI01010001010000000000000515BI01000014111no
301300od162616/2019_2020 : Providing and fixing following 100Amp,25 kA,FP MCCB rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.BI01010001010000000000000515BI01000014121no
302301od163019/2019_2020 : Supply of following 3.5C 185 Sq.mm Al size 1.1 KV grade XLPE insulated, PVC sheathed, armoured Aluminium conductor cable conforming to IS 7098 (Part 1) amended upto date.BI01010001010000000000000515BI010000141372metre
303302od164653/2019_2020 : Dismantling of existing switch gear in the existing panel cubicle and replacing with 160A TP+NL (25kA) MCCB with all other accessories as requiredBI01010001010000000000000515BI01000014141no
304303od258588/2019_2020 : Supply of indoor industrial surface mounted LED tube with Batten along with driver , surge protector,,system wattage of 40+/-4 Watts,lumen output of luminaire greater than 4000 lumen, power factor > 0.9,rated life of L70 @ 50,000 hours, system efficacy greater than 100lumen/watt and including all necessary accessories as required complete.Make:- Cat No: WIPRO OPTIMA ll24BI01010001010000000000000515BI0100001415142no
305304od258590/2019_2020 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate Diffuser with provision of End to End connection,along with driver,system wattage of 10+/-2 Watts,lumen output of luminaire greater than 1000, power factor > 0.9,rated life of L70 @ 35,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: OSRAM LUXSMART led BATTEN G2 or equivalent approved makeBI01010001010000000000000515BI010000141612no
306305od258595/2019_2020 : Supply of indoor decorative surface mounted LED Batten with Polycarbonate diffuser, along with driver,system wattage of 20+/-2 Watts,lumen output of luminaire greater than 2000, power factor > 0.9,rated life of L70 @ 35,000 hours, system efficacy greater than 100lumen/watt and including all the necessary accessories as required complete.Make:- Cat No: Osram Luxsmart LED batten G2 or equivalent approved makeBI01010001010000000000000515BI0100001417148no
307306od258647/2019_2020 : Supply installation, testing and commissioning of DOL starter upto 3 HP,3ph motor including auxiliary contactors , SPP, all the necessary accessories as required complete.BI01010001010000000000000515BI01000014186no
308307FIRE FIGHTING WORKS:\nod162861/2019_2020 : Supply, installation, testing and commissioning of electric driven pump set (terrace pump) suitable for automatic operation and consisting of following: complete in all respect as required and as per the technical specification. Monoblock Pump rated for 900lpm, 40 m head C.I body, bronze impeller,SS shaft with mechanical seal, volute type with suitable HP SQ cage induction motor, suitable for operation on 415V, 3phase 50Hz, AC with IP 55 class of protection for enclosure, horizontal foot mounted type with class F insulation.M.S. fabricated common base plate, foundation bolts, anti vibration pads etc. as required with all necessary accessories and cabling for successful automatic operation of the pump.BI01010001010000000000000515BI01000014191set
309308od162862/2019_2020 : Supply and installation of photoluminescent glow signage such as Fire Duct/Fire Lift/Staircase signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.BI01010001010000000000000515BI010000142010no
310309od162863/2019_2020 : Supply, installation, testing and commissioning of pressure gauge 0-200 PSI ( 0 -14 Kg ) range, 3/8 BSP bottom entry, 6 dial weather proof with stainless steel internals including fittings etc. complete as required as per technical specification.BI01010001010000000000000515BI01000014211each
311310od162864/2019_2020 : Supply and installation of photoluminescent glow signage for FIRE ORDER of standard size (500*800 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.BI01010001010000000000000515BI01000014226no
312311od162865/2019_2020 : Supply and installation of photoluminescent glow signage such as Emergency Exit/Fire Exit signage etc. of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.BI01010001010000000000000515BI01000014236no
313312od162866/2019_2020 : Supply and installation of ABC Stored pressure type Fire Extinguisher 6 Kgs Capacity Mono Ammonium Phosphate based Dry Chemical Powder as per IS 14609 with ISI Mark for Fighting ABC Class of Fire, stored Pressure type of Mild steel body pressurized by Nitrogen Gas. The Extinguisher shall have pressure gauge for indicating inside pressure with opening and closing lever of squeeze grip type with tamper proof seal, complete with wall bracket. The Extinguisher should be manufactured strictly as per IS: 15683:2018.BI01010001010000000000000515BI010000142413each
314313od162867/2019_2020 : Supply and installation of Carbon-dioxide extinguisher of ISI marked 4.5 Kg capacity made of high pressure seamless steel cylinder (CCE marked) complete with wheel type valve with one meter long braided high pressure discharge hose complete in all respects including initial fill with CO2 gas. complete as required as per the technical specification. The Extinguisher should be manufactured strictly as per IS: 15683:2018.BI01010001010000000000000515BI01000014251each
315314od162868/2019_2020 : Supply, installation, testing and commissioning of industrial type pressure switch having 1/4 BSP(F) connection IP:32 enclosure protection, phosphor bronze bellows as sensing element, SPDT contact system, switch rating 6A Inductive/lOA resistive 380 V AC, 0.2A Inductive/10A resistive 250V DC suit with ball valve etc. complete as required with necessary control cablings & wirings for successful system operation as per technical specification.BI01010001010000000000000515BI01000014261each
316315od162869/2019_2020 : Supply and installation of photoluminescent glow signage for FIRE ASSEMBLY POINT of standard size (500*200 MM) as per conventional design/ colour code on 3 mm thick aluminium composite panel and conforming to IS 9457, IS12349, IS12407. The signage will be either fixed on the wall with the help of screws & double tape or hanged from the false ceiling with the help of chain & screws etc. complete as required as per the technical specification.BI01010001010000000000000515BI01000014272no
317316od162870/2019_2020 : Supply and fixing (in appropriate location) of Fire Emergency Evacuation Plan (Color) Printed in Photo Paper of Size A2 sandwitched in Clear acrylic sheets fixed using SS Studs and other accessories complete as required as per the technical specification and conforming to IS 9457, IS12349, IS12407. Evacuation Plan shall be prepared by the contractor.BI01010001010000000000000515BI01000014286no
318317od162871/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 100 mm diaBI01010001010000000000000515BI0100001429124metre
319318od162872/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bbolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 80 mm diaBI01010001010000000000000515BI010000143057metre
320319od162873/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 65 mm diaBI01010001010000000000000515BI010000143135metre
321320od162874/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 50 mm diaBI01010001010000000000000515BI01000014329metre
322321od162875/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 40 mm diaBI01010001010000000000000515BI010000143368metre
323322od162876/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc., fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 32 mm diaBI01010001010000000000000515BI01000014348metre
324323od162877/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc, fixing the pipe on the wall/ceiling with suitable clamps and painting with one coat of primer and two coats of synthetic enamel paint of required shade complete as required as per technical specification. 25 mm diaBI01010001010000000000000515BI0100001435163metre
325324od162878/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification. - 100 mm diaBI01010001010000000000000515BI010000143610metre
326325od162879/2019_2020 : Supply, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 1239 including fittings like elbows, tees flanges, tapers, nuts bolts, gaskets etc. in ground at a depth of 1m including excavation & providing cement concrete blocks as supports, anticorrosive wrapping coating 4 mm thick as per IS 10221, refilling the trench etc. of following sizes complete as required as per technical specification. 80 mm diaBI01010001010000000000000515BI01000014372metre
327326od162881/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM liner,SS disc nitrile sheet,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 100 mm diaBI01010001010000000000000515BI01000014387each
328327od162882/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM liner,SS disc nitrile sheet,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 40 mm diaBI01010001010000000000000515BI01000014392each
329328od162883/2019_2020 : Supply,installation,testing and commissioning of gun metal fire hydrant valve ,single head oblique type with 63 mm instantaneous outlets with female socket for hose connection and inlet side with flange suitable for 80 mm pipe flange,valve conforming to IS:5290 complete with blank cap,Chain etc as per technical specificationBI01010001010000000000000515BI01000014408each
330329od162884/2019_2020 : Supply, installation, testing and commissioning of First-aid Hose Reel with MS construction spray painted in Post office Red, conforming to IS 884 with up to date amendments, complete with the following as required as per technical specification. (a) 30 m. long 20 mm (nominal internal dia water hose Thermoplastic (Textile reinforced) Type-2 as per IS: 12585. (b) 20 mm (nominal internal ) dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipments on wall. (d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. PipeBI01010001010000000000000515BI01000014417each
331330od162885/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with GI wire, rivets etc. conforming to IS 636 (type-A) as required as per technical specificationBI01010001010000000000000515BI010000144216each
332331od162886/2019_2020 : Supply, installation, testing and commissioning of 63 mm dia Gun metal branch pipe with 20 mm (nominal internal diameter) size Gun Metal nozzle conforming to IS 903, suitable for instantaneous connection to inter-connect hose pipe coupling as required.BI01010001010000000000000515BI01000014438each
333332od162887/2019_2020 : Supply, installation, testing and commissioning of hose boxes wall/pedestal type of size 750 x 250 x 600 mm made out of 16 SWG MS sheet steel with front side glass, locking arrangement and painted with approved colour completed as required and as per specifications.BI01010001010000000000000515BI01000014448each
334333od162888/2019_2020 : Supply, installation, testing and commissioning of Fire brigade collective breaching with 2 nos. of 100 mm flanged out let connection and built in check valves complete as required as per technical specificationBI01010001010000000000000515BI01000014451each
335334od162889/2019_2020 : Supply, installation, testing and commissioning of Air release valve, 25 mm dia complete as required as per the technical specificationBI01010001010000000000000515BI01000014463each
336335od162890/2019_2020 : Supply, installation, testing and commissioning of standard response, standard coverage sprinkler, upright type sprinkler ;1/2 NPT, K -5.6, Chrome Finish; operating temperature at 68 deg. C. complete as required as per the technical specification.BI01010001010000000000000515BI010000144762each
337336od162893/2019_2020 : Supply, Installation, Testing and Commissioning of 100mm dia Sprinkler alarm valve of Cast iron body and bronze working parts comprising of water motor alarm, bronze seat clapper, and clapper arm, hydraulically driven mechanical gong bell to sound continuous alarm when the Wet riser/Sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, GI pipe of required size, flanges, orifice plate, gasket etc. complete as required as per the technical specification.BI01010001010000000000000515BI01000014481set
338337od165940/2019_2020 : Supply, installation, testing and commissioning of dual plate non-return valve of following sizes having PN 16 pressure rating complete with CI body, ductile iron disc, SS plates vulcanized NBR seal flanged end, GI bolts, nuts, washers etc. as required as per technical specification and confirming to API:594. 100 mm diaBI01010001010000000000000515BI01000014492each
339338od165943/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM liner,SS disc nitrile sheet,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification.80 mm diaBI01010001010000000000000515BI01000014502each
340339od165944/2019_2020 : Supply, installation, testing and commissioning of butterfly valve of following sizes having PN 16 rating conforming to IS 13095 complete with CI body, EPDM liner,SS disc nitrile sheet,O -ring, flanges, bolts, nuts, washers etc. as required as per technical specification. 65mmBI01010001010000000000000515BI01000014511each

AI Tender Summary

OUR REF NO 23718901
AUTHORITY Government Departments
TENDER VALUE 8.50 Crore
LAST DATE 12-03-2020
Authority
Authority Name Kitco Limited
Work Description Augmentation Of Infrastructure Facilities At Mahakavi Vennikulam Gopalakurup Memorial Govt Polytechnic Vennikulam Pathanamthitta
Basic Detail
Tender No HED/KITCO/CL/29/2020
Bidding Type Tender
Location
City Vennikulam Pathanamthitta
State Kerala
Key Dates
Publish Date 20 Feb 2020
Submission Date 12 Mar 2020
Open Date 16 Mar 2020
Finance
Tender Value 8.50 Crore
Tender Fee 11800
EMD 2 Lakhs
Exemption Not Available
Document List
4DDEEBFB-6DDD-4BF5-9A2C-278B31ADAAF5.html
BOQ_483312.xls
Tendernotice_1.pdf
Technicalbidvennikulam.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 20, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 12, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 16, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4DDEEBFB-6DDD-4BF5-9A2C-278B31ADAAF5.html

xls

BOQ_483312.xls

pdf

Tendernotice_1.pdf

pdf

Technicalbidvennikulam.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders