Erection Of 3 Wire Lt Overhead Lighting Line Extension Of Existing Street Light Arrangement From Truck Entry Point To Mdtp Chowk And Utls Haul Road Main Gate To Near Darlipali Village New Road End Near Haul Road Of Bocm , Lakhanpur Area , Mcl, BOCM, Lakhanpur Area.-Odisha

Mahanadi Coalfields Limited has published Erection Of 3 Wire Lt Overhead Lighting Line Extension Of Existing Street Light Arrangement From Truck Entry Point To Mdtp Chowk And Utls Haul Road Main Gate To Near Darlipali Village New Road End Near Haul Road Of Bocm , Lakhanpur Area , Mcl. Submission Date for this Tender is 02-03-2020. Electrification Work Tenders in BOCM, Lakhanpur Area. Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

23714566
Erection Of 3 Wire Lt Overhead Lighting Line Extension Of Existing Street Light Arrangement From Truck Entry Point To Mdtp Chowk And Utls Haul Road Main Gate To Near Darlipali Village New Road End Near Haul Road Of Bocm , Lakhanpur Area , Mcl
Open Tender
Indian
Odisha
BOCM, Lakhanpur Area.
02-03-2020

Tender Details

Erection Of 3 Wire Lt Overhead Lighting Line Extension Of Existing Street Light Arrangement From Truck Entry Point To Mdtp Chowk And Utls Haul Road Main Gate To Near Darlipali Village New Road End Near Haul Road Of Bocm , Lakhanpur Area , Mcl

Key Value

Document Fees
Refer document
EMD
INR 3200.0 /-
Tender Value
INR 2.52 Lakhs /-

BOQ Items

Name of the Work / Contract No:
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required-Above 11 metre and upto 13 metre\n BI01010001010000000000000515BI0100001114 21 Each
2 2 Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required . BI01010001010000000000000515BI0100001115 21 set
3 3 Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.\n BI01010001010000000000000515BI0100001116 21 set
4 4 Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.\n BI01010001010000000000000515BI0100001117 137.16 kg
5 5 Supplying and Erection of stay set complete(galvanised) with 19/20 mm dia x 1.8 Metres long stay rod, anchor plate of size 45 cm x 45 cm x 7.5 mm , thimble , stay clamps , bow tightener,7/3.15mm dia G.I stay wire and strain insulator etc in cement concrete 1:3:6 ( 1 cement: 3 coare sand:6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. required\n BI01010001010000000000000515BI0100001118 4 Each
6 6 Supplying of 8 SWG GI wire \n BI01010001010000000000000515BI0100001119 95 kg
7 7 Erection of 8 SWG G.I. wire. including binding as required\n BI01010001010000000000000515BI0100001120 95 Kg
8 8 Supply & erection of 100 x 65 mm pin insulator complete with G.I spindle and nuts etc as reqd.\n BI01010001010000000000000515BI0100001121 52 Set
9 9 Supplying and Erection of 75mm x 90mm shackle insulator complete with GI strip, bolt and nut etc. as req.\n BI01010001010000000000000515BI0100001122 18 Set
10 10 Painting with aluminium paint of approved brand and manufacture to give an\neven shade.(one or more coats on old work.) BI01010001010000000000000515BI0100001123 146.87 Sq.Mtr
11 11 Supply and erection of 90 watt LED street light.\n1 .LED Rating (System Wattage), Rated Power 90W\n2 .Ingress Protection (IP Rating) - As Per IS:10322 (Part 1): 1982 Latest IP66\n3. Warranty For Free Replacement (In Years) 3\n4 .Input Operating Voltage Range And Frequency 140 to 270 V olts AC at 50 Hz+/-2 Hz with auto cutt off at below 120V\n5. Optic Lense Materal (UV Stabilised) Poly carbonate lense\n6 .Operating Temperature Range (-10 °C To +55 °C)\n7 .The Luminaire Shall Be Protected Against Surges And Transients Of >::=10KV (External) -Yes\n8. Number Of Electronic Control Gear (Power Supplies) -1\n9. Length Of ISI Marked Three Core Wire (Shall Be Provided Along With Supply Of Material) 50cm\n10. The Luminaire Shall Be Protected Against Surges And Transients ( Internal) >/=5KV\n11. Colour temperature (+/-500K) 6000K\n12. LED Luminaire conformity to IS:10322/Part 5/Section 5/2012 latest and IS: 16107 (Part 2/Sec 1):2012 latest Yes\n13 .Types of LED Luminaire as per the IS: 16107(Part-2/ Sec.-1)/2012 Type B\n14 .Types of LED Modules as per the IS:IS: 16103(Part-2)/2012 Type 3\n15. Luminaire System Efficacy (Lumen/watt) >/= 100 Lm/Watt\n16. AC Power Factor at full load = 0.95\n17. Driver Efficiency (in %age) Upto 100W: =85% Yes\n18. LED chip Efficacy =130 Lm/Watt\n19. Heat sink should be die-cast aluminium along with sufficient heat sink fins to dissipate heat effectively Yes\n20. Working life for LED (Minimum 50,000 burning hours as per LM-80 and LM 21 reports) Yes\n21. Insulation resistance between earth and current carrying part >100 M ohm\n BI01010001010000000000000515BI0100001124 22 Nos.
12 12 Suuply and fixing of 200Amps/415V TPN switch unit , \nSpecification of ICTPN\nCurrent Rating-200Amps,\nICTPN main switch shall confirm to IS/IEC 60947-3:1999 with latest amendment and should be ISI marked\nICTPN main switch should have high operating safety, Fine finish, Heavy Duty, \nLive parts are made up of high conductivity electrolytic copper/ brass, Conduit knockouts/cable glands at top and bottom rewire able type, Enclosure should be CRCA sheet, powder painted to ensure strong and scratch resistance coating. BI01010001010000000000000515BI0100001125 1 Nos.
13 13 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.\n BI01010001010000000000000515BI0100001126 21 Nos.
14 14 Total impact of GST for the purpose of CTC BI01010001010000000000000515BI0100001130 1 Nos