Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #23701827

Repairs And Maintenance Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Connected Items At Likabali Mil Stn Under Ge 872 Ews Repairs And Maint Of Security/Perimeter Lights/High Mast Lights/Solar Lights/Garden Lights And Conne

Issued by Statutory Bodies & Commissions/Committees · LIKABALI, Assam
Tender Value
19 Lakhs
Estimated cost
Bid Submission
05 Mar 2020
0 days left
EMD
38000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
LIKABALI → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repairs And Maintenance Of Security / Perimeter Lights / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Likabali Mil Stn Under Ge 872 Ews Repairs And Maint Of Security / Perimeter Lights / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Likabali Mil Stn Under Ge 872 Ews ( 8760 / T-60 / E8 )

BOQ

NAME OF WORK : REPAIRS & MAINT OF SECURITY/PERIMETER LIGHTS/HIGH MAST LIGHTS/SOLAR LIGHTS/GARDEN LIGHTS & CONNECTED ITEMS AT LIKABALI MIL STN UNDER GE 872 EWS
Sl.No.Item DescriptionItem Code / MakeQuantityUNITS
11M&L Taking down Street/Perimeter Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'.BI01010001010000000000000515BI0100001113400EACH JOB
22Supply only Tube/Rod 1x14 Watt (as approved) suitable for T-5 Light Fitting 4x14 Watt, complete all as specified and as directed.BI01010001010000000000000515BI0100001114200EACH
33Supply only Electronic Ballast 2x14 Watt (as approved) suitable for T-5 Fitting 4x14 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000111550EACH
44Supply only PVC Holder (as approved) suitable for T-5 Fitting, 4x14 Watt complete all as specified and as directed.BI01010001010000000000000515BI010000111650EACH
55Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000111720EACH
66Supply only Driver (as approved) suitable for LED Street Light Fitting 45 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000111830EACH
77Supply only Driver (as approved) suitable for LED Street Light Fitting 48 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000111930EACH
88Supply only Driver (as approved) suitable for LED Street Light Fitting 60 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000112020EACH
99M&L Lowering down High Mast Lights, Repairing High Mast Light by apply Greasing, Oiling, etc., Repairing as required, Re-hoisting High Mast Lights after Repaired including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional) will be Measured and Paid separately under respective Items as 'Supply only'.BI01010001010000000000000515BI01000011216EACH JOB
1010Supply only Driver (as approved) suitable for LED Flood Light Fitting 120 Watt, complete all as specified and as directed.BI01010001010000000000000515BI010000112210EACH
1111Supply only LED Flood Light 1x120 Watt (as approved), complete all as specified and as directed.BI01010001010000000000000515BI01000011239EACH
1212M&L Taking down Solar Light Fitting of any type and any capacity from any Height, Replacing Defective/ Unserviceable Spares/ Parts, Applying Mineral Jelly to the Battery Terminal(s), Tightening of All Connections, Cleaning of Solar Panel throughly, Filling Distilled Water to Solar Light Batteries, Re-fixing the Solar Light Fitting in Original Position, complete all as specified and as directed.\nNOTE : New Spares/Parts (Quantites are Provisional), Distilled Water, etc. will be Measured and Paid separately under respective Items as 'Supply only'BI01010001010000000000000515BI010000112434EACH JOB
1313Supply only Tinned/ Copper Battery Terminal (as approved), complete all as specified and as directed.BI01010001010000000000000515BI010000112510EACH
1414Supply only Solar Battery 12 Volt, 75 AH, Dry Gel (as approved) suitable for 3 Days Backup capacity, complete all as specified and as directed.BI01010001010000000000000515BI01000011265EACH
1515Supply only Distilled Water suitable for Solar Light Batteries, complete all as specified and as directed.BI01010001010000000000000515BI010000112748LITRE
1616S&F LED Street Light Fitting 30 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPSBI01010001010000000000000515BI010000112820EACH
1717S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.\nMAKE : BAJAJ/ CG/ C&S/ HAVELS/ PHILIPSBI01010001010000000000000515BI010000112921EACH
1818S&F BAMBOO Light Fitting, New Generation, Environmental Friendly, Energy Saving, Long Life, Aesthetically Designed, Aluminium Landscape Luminaire for Diffused Lighting with High Power LED as Light Source, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0 M) or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GEBI01010001010000000000000515BI010000113010EACH
1919S&F RUBY (CLEAR), New Generation, Post Top, New Generation, Energy Saving, Environmental Friendly, Long Life, Aesthetically Designed with Symmetrical Light Distribution, Spun Aluminium Landscape Luminaire with High Power LEDs as Light Source, IP-65 protected, suitable for Pole 76mm dia, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. RUBYPT25WLED757PSYMTOPC or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GEBI01010001010000000000000515BI010000113110EACH
2020S&F MOON (PRISMAT IC) Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 8 Watt/ 14 Watt (TU)/ LED Lamp B-22 Base Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. LHFXBON1TN6F023 or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GEBI01010001010000000000000515BI010000113260EACH
2121S&F GRACE Small Decorative Gate Light Fitting, made up of High Grade Unbreakable Polycarbonate Material suitable for Retrofit CFL 20 Watt Spiral/ 10 Watt LED Bulb with B-22 Base, having Mounting Pole Dia - 60mm (Max) OD, Width: 160mm & Height : 284mm, Providing Electric Connections including Taking down Unserviceable Light Fitting of any description, complete all as specified and as directed.\nMAKE : HAVELS, Cat No. LHFHASN1TL4K015 or equivalent in Make : BAJAJ/ CG/ C&S/ PHILIPS as approved by GEBI01010001010000000000000515BI010000113312EACH
2222S&F PVC insulated Aluminium Wire 1.5 Sqmm, 3 Core for Providing Connection from Overhead Line to Street Light Fitting including Taking down Unserviceable Wire of any description, complete all as specified and as directed.BI01010001010000000000000515BI0100001134200RUNNING METRE
2323Dismantling Unserviceable LT Steel Tubular Pole of any description and any size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed.\nNOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.BI01010001010000000000000515BI01000011355EACH JOB
2424Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.BI01010001010000000000000515BI01000011360.5QUINTAL
2525Taking down Unserviceable/ Rusted GI Earth Wire, Cradles Guards of any size from LT Electric Poles of any size and capacity, complete all as specified and as directed.BI01010001010000000000000515BI01000011371QUINTAL
2626Taking down ACSR Conductor of any size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed.BI01010001010000000000000515BI01000011380.5QUINTAL
2727Dismantling Stay Assembly complete of any description, complete all as specified and as directed.\nNOTE : Unserviceable Stay Assembly will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earth Works, Demolition of Cement Concrete, etc. will not be Measured & Paid separatelyBI01010001010000000000000515BI01000011395EACH SET
2828Disconnecting & Taking down/out unserviceable LT Cable of any size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed.\nNOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.BI01010001010000000000000515BI0100001140650RUNNING METRE
2929Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.BI01010001010000000000000515BI0100001141230CUBIC METRE
3030Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.BI01010001010000000000000515BI01000011420.3CUBIC METRE
3131Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.BI01010001010000000000000515BI0100001143190CUBIC METRE
3232Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.BI01010001010000000000000515BI010000114430.3CUBIC METRE
3333Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.BI01010001010000000000000515BI010000114520RUNNING METRE
3434M&L Cutting Existing Road not exc. 1.50 Metre in depth and not exc. 1.50 Metre wide including Making Good the same to match the Original Surface level with Cement Concrete after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed.\nNOTE : Cement Concrete will be Measured and Paid separtely under appropriate Item.BI01010001010000000000000515BI010000114620RUNNING METRE
3535M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.BI01010001010000000000000515BI01000011470.2CUBIC METRE
3636M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.BI01010001010000000000000515BI01000011485CUBIC METRE
3737M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.BI01010001010000000000000515BI010000114915CUBIC METRE
3838M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed.\nNOTE : Necessary Earth Work & Cement Concrete will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI01000011505EACH JOB
3939M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.BI01010001010000000000000515BI01000011510.5QUINTAL
4040S&F Insulator Pin type, 100mm height, 65mm dia Porcelain, Vitreous, White, Brown or Green for 1100 Volt grade including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down unserviceable Insulator, complete all as specified and as directed.BI01010001010000000000000515BI010000115210EACH
4141S&F Insulator Shackle type, Porcelain, Vitreious, white brown or green of size 100mm High & 115mm dia including Galvanised Mild Steel Straps of Section 31x5.0mm, 14mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed.BI01010001010000000000000515BI010000115310EACH
4242S&F Insulator Loop type, Small in size, Vitreous Porcelain, white, borwn or green with Overall Dimensions 65x90mm, Clearance of Hole 16mm 1100 Volt grade including Taking down unserviceable Insulator, complete all as specified and as directed.BI01010001010000000000000515BI01000011542EACH
4343M&L Galvanised Iron Wire 4.0mm dia (8 SWG) as Continuous Earth Wire, Guards and Cradles (hexagonal/rectangular), etc. and binding with and including GI Binding Wire 1.6mm dia, complete all as specified and as directed.BI01010001010000000000000515BI01000011551QUINTAL
4444M&L ACSR Conductor of any size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed.\nNOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge.BI01010001010000000000000515BI01000011560.5QUINTAL
4545M&L Restretching, Tightening & Fixing of ACSR Conductor of any size on LT Electric Poles including necessary Aluminium Binding Wire, Connectors, PVC Sleeves for Jumper, etc. complete all as specified and as directed.\nNOTE :-\n(a) The above Work includes Cleaning/Tremming of Tree Branches of any dia falling around the ACSR Conductors.\n(b) One Length shall be measured for complete Span comprising of any numbers of ACSR Conductor(s) & GI Wire(s).BI01010001010000000000000515BI0100001157100EACH SPAN
4646S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 2/3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.BI01010001010000000000000515BI0100001158100EACH
4747M&L Stay Assembly complete with all Accessories such as Mild Steel Galvanised Flat Iron Stay Clamp, Galvanised Stay Wire 7/4.0mm stranded, One Insulator Loop type Porcelain Vitreous (white, brown or green) Overall Dimensions 90x140mm and Clearance of Hole 25.5mm, Stay Grips, Mild Steel Galvanised Stay Bow, Thimbles Galvanised steel 14mm dia & 400mm long, 20mm dia Mild Steel Galvanised Stay Rod 1900mm long and Mild Steel Galvanised Stay Plate of size 300x300x6.0mm all as shown in Electrical Plate No. 1 of MES Schedule Part-I, complete all as specified and as directed.\nNOTE : Necessary Earth Work, Cement Concrete, etc. will be Measured and Paid separately under relevant Items.BI01010001010000000000000515BI01000011595EACH SET
4848M&L Trimming/Cutting of Tree Branches of any girth/size and Clearing of LT OH Lines (any Nos. of ACSR Conductors, Earth Wire, etc.) upto 3.00 Metre distance, Removing Tree Branches from the Sites, complete all as specified and as directed.BI01010001010000000000000515BI0100001160150EACH SPAN
4949M&L Painting LT Pre-stressed Concrete Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with Two coats of Cement Based Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.50 Metre height above Ground Level, complete all as specified and as directed.BI01010001010000000000000515BI0100001161100EACH JOB
5050M&L Painting LT Steel Tubular Pole including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour Synthetic Enamelled Paint for Pole 7.50 Metre height above Ground Level, complete all as specified and as directed.BI01010001010000000000000515BI0100001162100EACH JOB
5151M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001163300RUNNING METRE
5252M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 25 Sqmm, 4 Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001164100RUNNING METRE
5353M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 35 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001165150RUNNING METRE
5454M&L XLPE insulated, armoured heavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 185 Sqmm, 3½ Core, laid in Trenches/Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001166100RUNNING METRE
5555Taking down unserviceable LT Cable Cross-sectional area 6 Sqmm 2 Core to 16 Sqmm 2 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001167100RUNNING METRE
5656Taking down unserviceable LT Cable Cross-sectional area 10 Sqmm 4 Core to 25 Sqmm 4 Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001168100RUNNING METRE
5757Taking down unserviceable LT Cable Cross-sectional area 35 Sqmm 3½ Core to 70 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001169100RUNNING METRE
5858Taking down unserviceable LT Cable Cross-sectional area 120 Sqmm 3½ Core to 185 Sqmm 3½ Core, 1100 Volt grade from any Situation, finding out Cable Fault and Rectification of Cable Fault as ordered, Relaying/ Re-fixing the Cable after rectification, complete all as specified and as directed. \nNOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GI Pipe, etc. will be Measured and Paid separately under relevent Items.BI01010001010000000000000515BI0100001170100RUNNING METRE
5959M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed.\nNOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.BI01010001010000000000000515BI010000117170CUBIC METRE
6060Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of size 300x180x40mm thick, Class LV, Type 2, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.BI01010001010000000000000515BI01000011724300EACH
6161M&L Galvanised Steel Tubing Pipe 40mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.BI01010001010000000000000515BI010000117320RUNNING METRE
6262M&L Galvanised Steel Tubing Pipe 50mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.BI01010001010000000000000515BI010000117420RUNNING METRE
6363M&L Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.BI01010001010000000000000515BI010000117520RUNNING METRE
6464S&F MCCB 63 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connections and fixing to Existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed,BI01010001010000000000000515BI01000011761EACH
6565S&F MCCB 100 Amp 4 Pole, 35 kA, 415 Volt, 50 Hz including Outgoing and Incoming Cable Connections and fixing to Existing Panel Board including Taking down/out unserviceable MCCB, complete all as specified and as directed,BI01010001010000000000000515BI01000011771EACH
6666S&F On Load Change Over Switch (Front Operated) Open Execution, 100 Amp rating, 4 Pole, 415 Volt and connecting up including Taking down/out unserviceable Change Over Switch, complete all as specified and as directed.BI01010001010000000000000515BI01000011781EACH
6767Supply, Installation, Commissioning & Testing Factory made LT Feeder Pillar Box of size 1200x1000x450mm, made out of 3.15mm thick CRCA Sheet, Outdoor Type, Platform mounted, suitable for 415 Volt, 3 Phase, 4-Wire System, 50 Hz, supply having Aluminum Bus-bar 300 Amp for Phase and Neutral, installed on Porcelain/Epoxy Insulator, Dust and Vermin Proof (IP54), Painted with Two Coats of Sysnthetic Enamel Paint, Self mounted type with Mild Steel angle Iron 50x50x6.0mm Frame on front and Rear Opening with Double Shutter having Locking Arrangements with Mild Steel Lock 50mm in size, complete with Fixing Arrangements viz Mild Steel Bolts, Nuts, Washers, etc. and grouting of LT Feeder Pillar Box/ Panel in Cement Concrete 1:2:4 (20mm graded Stone Aggregates) Work, comprising of with the followings including Taking down unserviceable/ rusted Sheet Metal Encloser/ Bus-bar :-\n(a) Copper Bus-bar 4 Strip 300 Amp, 415 Volt - 01 Set\n(b) Space for fixing MCCB 100 Amp, 4 Pole, 35 kA, 415 Volt - 02 No.BI01010001010000000000000515BI01000011792EACH JOB
6868M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/out Unserviceable Earthing, complete all as per specified and as directed.BI01010001010000000000000515BI010000118010EACH SET
6969M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with and including Galvanised Earth Strip of size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) Light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking Taking down/out Unserviceable Earthing, complete all as per specified and as directed. \nNOTE : All Joints should be joined by Exothermic Welding or Brazing.BI01010001010000000000000515BI010000118110EACH SET

AI Tender Summary

OUR REF NO 23701827
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 19 Lakhs
LAST DATE 05-03-2020
Authority
Authority Name Military Engineer Services
Work Description Repairs And Maintenance Of Security / Perimeter Lights / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Likabali Mil Stn Under Ge 872 Ews Repairs And Maint Of Security / Perimeter Lights / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Likabali Mil Stn Under Ge 872 Ews ( 8760 / T-60 / E8 )
Basic Detail
Tender No 8760/T-60/E8
Bidding Type Tender
Location
City LIKABALI
State Assam
Key Dates
Publish Date 19 Feb 2020
Submission Date 05 Mar 2020
Open Date 06 Mar 2020
Finance
Tender Value 19 Lakhs
Tender Fee 500
EMD 38000
Exemption Not Available
Document List
RevisedTenderT60.pdf
BOQ_365312.xls
7BD4DDA6-57D9-4447-ADF7-2AF001AEE6DF.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 19, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 05, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 06, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

RevisedTenderT60.pdf

xls

BOQ_365312.xls

html

7BD4DDA6-57D9-4447-ADF7-2AF001AEE6DF.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders