Maintenance/Repair To Ceiling Fan And Other Fans And Replacement Of Electric Energy Meter Under Ge North Bathinda At Bathinda Mil Stn, Bathinda Mil Stn-Punjab

Military Engineer Services-MES has published Maintenance/Repair To Ceiling Fan And Other Fans And Replacement Of Electric Energy Meter Under Ge North Bathinda At Bathinda Mil Stn. Submission Date for this Tender is 09-03-2020. Energy Meter Tenders in Bathinda Mil Stn Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

23686411
Maintenance/Repair To Ceiling Fan And Other Fans And Replacement Of Electric Energy Meter Under Ge North Bathinda At Bathinda Mil Stn
National Competitive Bid
Indian
Punjab
Bathinda Mil Stn
09-03-2020

Tender Details

Maintenance/Repair To Ceiling Fan And Other Fans And Replacement Of Electric Energy Meter Under Ge North Bathinda At Bathinda Mil Stn

Key Value

Document Fees
INR 500 /-
EMD
INR 82000.0 /-
Tender Value
INR 41 Lakhs /-

BOQ Items

Name of Work : MAINT/REPAIR TO CEILING FAN AND OTHER FANS AND REPLACEMENT OF ELECTRIC ENERGY METER UNDER GE NORTH BATHINDA AT BATHINDA MIL STN
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Disconnecting electric connection and taking down carefully defective/unserviceable ceiling fan/exhaust fan/wall mounted fan/cabin fans/table fans etc ( of any size/make) from site as directed and deposit in AGE E/M Store yard complete all as specified and as directed by Engineer-in-charge. \nNote :- (i) The T & P/vehicles will be arranged by the contractor and the cost deemed to be included in the quoted unit rates. 3955 Each
2 2 Collecting serviceable/repaired ceiling fan and exhaust fans (any size/make) from E/M store yard and hanging/fixing at site as directed including electric connection with new flexible copper cable, including supply and fixing new mild steel clamp complete with rubber reel, GI nut bolts, split pin and lock washer (all heavy duty as per sample) for hanging of ceiling fan and nut bolts/screw, PVC gutties etc for hanging of exhaust fan complete all as specified and as directed by Engineer-in-charge.\nNote : (i) Cost for new flexble cable (make: FINOLEX/ Polycab/HPL/Anchor/ PARAGON/ HAVELLS/Plaza), mild steel clamp, rubber reel, GI nut bolt, split pin, washer, screw, PVC gutties etc shall deemed to be included in the quoted unit rates nothing shall be paid extra on this account.\n (ii) Blade set, PVC canopy set etc if required the same shall be measured and paid separetaly under appropriate item of BOQ as supply only 3905 Each
3 3 Collecting serviceable/repaired wall mounted fan/cabin fans/pedestral fans/table fans etc (any size/make) from E/M store yard and hanging/fixing/deposit to users site as directed including electric connection with existing electric system complete all as specified and as directed by Engineer-in-charge. \nNote : (i) Blade set if required the same shall be measured and paid separetaly under appropriate item of BOQ as supply only 50 Each
4 4 Material and labour for collecting unserviceable ceiling fan 1200mm sweep 230 V, AC supply, single phase, any make/model from E/M store yard of GE(N) Bathinda, Dismantling the ceiling fan and taking out complete burnt winding, thoroughly cleaning the core and all other components of the fan, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original, using insulating material paper sleeves and varnish class ‘B’ for insulation, well drying, replacement of rusted /unserviceable nuts, bolts, machine screws etc including oiling/greasing and replacement of defective / unserviceable parts/spares i.e. ball bearing, gun metal bush as required, reassembling the fan as per original and testing the fan on-load for two hours and deposting the complete repaired fan to E/M store yard of GE(N) Bathinda complete all as specified and as derected by Engineer-in-charge. Make for varnish : Dr Beck Insulating Varnish / HI-GRADE / LUREX / FINE FINISH / JYOTI Polyester Varnish / N S SHAH & Co.\nNote : Copper winding wire and all defective/ unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate item of BOQ as supply only and shall be issued to contractor under Sch ‘B’ on proper issue voucher and labour for winding and replacement of parts and insulation material shall be included in the unit rate. 3240 Each
5 5 All as per above Srl item No. 04 but for ceiling fan 1400mm sweep complete all as specified and as directed by Engineer-in-charge. 360 Each
6 6 All as per above Srl item No. 04 but for exhaust fan 400/450mm sweep complete all as specified and as directed by Engineer-in-charge. 55 Each
7 7 All as per above Srl item No. 04 but for exhaust fan 230 to 380mm sweep complete all as specified and as directed by Engineer-in-charge. 250 Each
8 8 All as per above Srl item No. 04 but for air circulator any sweep complete all as specified and as directed by Engineer-in-charge. 6 Each
9 9 All as per above Srl item No. 04 but for table fan or pedestal fan any sweep complete all as specified and as directed by Engineer-in-charge. 22 Each
10 10 All as per above Srl item No. 04 but for wall mounting fan or cabin fan any sweep complete all as specified and as directed by Engineer-in-charge. 22 Each
11 10.01 Note for item No.04 to 10 above :- (i) Copper winding wire and all defective/ unserviceable parts/items like bush, bearing, condenser, blade etc. shall be measured and paid separetaly under appropriate item of BOQ as supply only and shall be issued to contractor under Sch ‘B’ on proper issue voucher and labour for winding and replacement of parts and insulation material shall be included in the unit rate.\n(ii) The contractor will make arrangement for re-winding of fan at MES AGE E/M Store yard. The store/space for workshop will be provided by the department.\n(iii) MES No. of fan and GE (N) if missing, re-write the same as directed with sy-enamel paint and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.\n(iv) The necessary winding machine/T & P/vehicles shall be arranged/brought by the contractor and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.
12 11 Supply only super enamelled Copper winding wire suitable for motor winding of ceiling fans/exhaust fans/wall mounted fan/cabin fans/pedestral fans/table fans etc complete all as specified and as derected by Engineer-in-charge.\n(Make for winding wire :- Devidyal/HTP Thulax/Chetak/Atlas 650 Kg
13 12 Material and labour for lath work to any type of fan for taking out/cutting by machine bush/bearing from the body part of ceiling fan and replacing it with suitable size of ball bearing/bush as per matching size to shaft making necessary bearing boring, polishing of shaft Complete all as specified and as directed by Engineer-in-charge. \nNote : - Bearing/bush (supply only) shall be measured and paid separately under respective item of BOQ. 500 Each
14 13 Supply only ball bearing of No. 6201/6202/6203 or as per requirement suitable for ceiling fan of sweep 1200/1400mm complete all as specified and as directed by Engineer-in- Charge.\nMake :- SKF/NBC/TATA/FAG/NSK 3800 Each
15 14 Supply only ball bearing suitable for exhaust fan/wall mounted fan/cabin fans/pedestral fans/table fans etc of any sweep complete all as specified and as directed by Engineer-in- Charge.\nMake :- SKF/NBC/TATA/FAG/NSK 350 Each
16 15 Supply only gun metal bush suitable for any type and sweep of fan complete all as specified and as directed by Engineer-in- Charge.\nMake :- SKF/NBC/TATA/FAG/NSK 500 Each
17 16 Supply only capacitor/condenser oil filled/dry of capacity 2.5 Mfd (ISI marked) suitable for any type of fan complete all as specified and as directed by Engineer-in-charge.\nMake :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens/Jyoti 6400 Each
18 17 Supply only capacitor/condenser oil filled of capacity 3.15/4.00/6 Mfd (ISI marked) suitable for any type of fan complete all as specified and as directed by Engineer-in-charge.\nMake :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens/Jyoti 400 Each
19 18 Labour only for fixing the capacitor of any capacity and any type in replacement (in existing fans installed at any site) complete all as specified and as directed by Engineer-in-charge.\nNote :- (i) New Capacitor shall be measured and paid separetaly under appropriate item (supply only item, here-in-before) of BOQ and shall be issued under Sch 'B' free for fixing only. 500 Each
20 19 Supply only in replacement mild steel fan blade set suitable for ceiling fan of sweep 1200mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge. 350 Set of three
21 20 Supply only in replacement mild steel fan blade set suitable for ceiling fan of sweep 1400mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge. 45 Set of three
22 21 Supply and Fixing in replacement fan blade (aluminium) set suitable for exhaust fan of sweep 400/450mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge. 12 Each
23 22 Supply and Fixing in replacement fan blade (aluminium) set suitable for exhaust fan of sweep 230 to 380mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge. 40 Each
24 23 Supply and Fixing in replacement fan blade (aluminium) set suitable for table/pedestal /air cirulator/wall mounted fan of any sweep and make/model duly painted as per sample or as directed by Engineer-in-charge. 5 Each
25 24 Supply and fixing in replacement PVC canopy (top or bottom) suitable for suitable for ceiling fan of 1200 / 1400 mm sweep any make/model complete all as specified and as directed by Engineer-in-charge. 500 Each Set
26 25 Disconnecting electric connection and taking down carefully ceiling fans ( of any size/make) from site as directed, material and labour for washing, oiling, dismantling carefully blades/canopy, removing/washing/cleaning of dust properly with detergent powder, including necessary minor repair/lose connection/replacement of capacitor if required, reassembling the fan as per original including testing and hanging/fixing at same site including electric connection with copper flexble cable (make: FINOLEX/ Polycab/HPL/Anchor/ PARAGON/ HAVELLS/Plaza) complete all as specified and as directed by Engineer-in-charge.\nNote :- (i) Fan shall be repaired/washing at site and shall not be taken away of user's permisses. (ii) Capacitor if required (if burnt/unserviceable), the same shall be measured and paid separetaly under appropriate item of BOQ and shall be issued to contractor under Sch ‘B’ on proper issue voucher. (iii) MES No. of fan and GE (N) if missing, re-write the same as directed with sy-enamel paint and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.\n 4400 Each Job
27 26 Material and labour for painting to ceiling Fan of any sweep/size/make, checking nut bolts and replace if required, painting the fans (at store yard of AGE E/M or as per direction of Engineer-in-charge) complete including fan body, blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint, cleaning all dust / spoil and greasy spots and including using filler for filling cavities, painting to fan in white/Black/Grey paint or as approved by Engineer-in-charge. After painting MES No and GE (N) shall be marked with red colour synthetic enamel paint using stencil as per existing number complete all as specified and as directed by Engineer-in-charge. 300 Each
28 27 Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (one module), 100 watt, 250 volts, fixed on existing sheet/frame complete all as specified and as directed by Engineer-in-charge.\nMake :- ANCHOR/LEGRAND/PHILLIPS/HAVELLS 650 Each
29 28 Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, fixed on existing sheet/frame complete all as specified and as directed by Engineer-in-charge.\nMake :- ANCHOR/LEGRAND/PHILLIPS/HAVELLS 200 Each
30 29 Supply and fixing in replacement switch piano flush type, 5/6Amps, 250 volts, single pole, one way fixed on existing sheet/board complete all as specified and as directed by Engineer-in-charge. Make : ANCHOR/ SSK/ HAVELLS/ Vinay/ LEGRAND 250 Each
31 30 Hanging only new ceiling fan any sweep / make / model including writing/marked alotted MES No and GE (N) on fan with red colour synthetic enamel paint using stencil complete all as specified and as directed by Engineer-in-charge.\nNote :-Ceiling fan issued by departmet under Sch B free for fixing. 400 Each
32 31 Dismantling the geysers from the site for necessary repair such as descaling, drain out water, cleaning rust particles from tank and body by using recommended chemicals, including all necessary minor repair, arresting the leakages etc and re-fixing the geyser at site in original position including connecting with electric and water supply system complete all as specified and as directed by Engineer-in-Charge. 350 Each
33 32 Supply and fixing in replacement Heating element 2 KW, 230 volts AC supply (as per original ISI marked ), suitable for geyser (any type) complete with rubber gasket including replacing the rusted bolts/screw if required during changing the heating elements, complete all as specified and as directed by Engineer-in-Charge. \nMake: Victor/ Power pack/ sunflame/ Intersolar/Daspass/Suraksha 180 Each
34 33 Supply and fixing in replacement 600 mm long PVC connection 15mm size with Brass CP nuts heavy duty suitable for hot water complete all as specified & directed by Engineer-in-charge. 400 Each
35 34 Supply and fixing in replacement of Thermostat 0 to 80 deg celcius setting suitable for 25/35/50 Ltr electric water storage geyser and solar water heaters complete all as specified and as directed by Engineer-in-Charge. Make- Elcon/Nenus/power king 250 Each
36 35 Supplying, fixing, testing, and commissioning AC 240 volt single phase tamper proof electronic whole current energy meter (Polycarbonate body LCD display), accuracy class 1.0, rating range 10 Amp to 60 Amp, with pilfer proof meter box and sealing screw, The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED indication of line load reversal and earth loading indication and shall work satisfactory with guarantee acuracy as per limit of IS-13779. The meter shall be fixed in existing steel box on wall including cable connection (inlet and outlet) and proper sealing with KWH lead sealing tablets & wire including taking down old meter and deposited to AGE E/M-V office with details such as building No., old meter No., New meter No, initial reading, date of installation etc. complete all as specified and as directed by Engineer-in-Charge. \nMake : Cat part No. SPPB1510000002OC00 of HPL or equivalent model of L & T/ Havelles / ABB 446 Each
37 36 Note:- (i) The penalty shall be applicable to the contractor if the delay is noticed to attend the complaints by the EIC. (ii) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail