Structural Audit And Issue Of Structural Audit And Issue OfStability Certificate In RespectOf Workshop Structures /Buildings And Residential BuildingsOf Mazagon Dock ShipbuildersLimited At Dockyard RoadPremises And Anik Chembur YardIn Mumbai
Tender Overview
Project Description
Structural Audit And Issue Of Structural Audit And Issue OfStability Certificate In RespectOf Workshop Structures /Buildings And Residential BuildingsOf Mazagon Dock ShipbuildersLimited At Dockyard RoadPremises And Anik Chembur YardIn Mumbai . , Professional Fee For Structural Audit And Issue Of Stability Certificate For All Existing Workshop Structures / Buildings ( North Yard , South Yard , East Yard , Alcock Yard & Residential Area ) Of Mazagon Dock Shipbuilders Limited Premises At Dockyard Road And Anik Chembur Yard In Mumbai As Per List Of Workshop Structures/Buildings Detailed At Enclosure-23 And Scope Of Work At Tef Clause No . 2 ) , Carrying Out Rebound Hammer Test ( Non Destructive Test ) Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours , Carrying Out Ultrasonic Pulse Velocity Test ( Non Destructive Test ) Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours , Carrying Out Core Test With 40Mm Dia . Core Including All Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours . Re-Filling The Holes With Micro Concrete , Finishing , Etc . Complete , Carrying Out Carbonation Test Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours . , Carrying Out Corrosion Rate Assessment & Half Cell Potential Test For Steel Members With All Tools & Tackles And As Instructed By Eic , Carrying Out Chemical Analysis For Ph Value , Chloride Content , Sulphate Content , Cement Content Tests Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours . , Carrying Out Ultrasonic Thickness Gauge ( Tg ) Test Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours . , Carrying Out Transient Dynamic Response ( Tdr ) For Slab Structure Including All Testing Equipment , Tools , Ladders , Scaffolding Etc . Along With Technicians And Skilled/Unskilled Labours ,
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Mar-2020 | Corrigendum-I | Date | 26-Mar-2020 |
| 2 | 20-Mar-2020 | Corrigendum-II | Date | 15-Apr-2020 |
BOQ
| Name of Work: STRUCTURAL AUDIT & ISSUE OF STABILITY CERTIFICATE IN RESPECT OF WORKSHOP STRUCTURES / BUILDINGS & RESIDENTIAL BUILDINGS OF MAZAGON DOCK SHIPBUILDERS LIMITED AT DOCKYARD ROAD PREMISES AND ANIK CHEMBUR YARD IN MUMBAI | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Professional Fee for Structural Audit and Issue of Stability Certificate for all existing Workshop Structures / Buildings (North Yard, South Yard, East Yard, Alcock Yard & Residential area) of Mazagon Dock Shipbuilders Limited premises at Dockyard Road and Anik Chembur Yard in Mumbai as per List of workshop structures/buildings detailed at Enclosure-23 and scope of work at TEF Clause no. 2) | item1 | 2.15858e+06 | SqFt |
| 2 | 2 | Carrying out Rebound Hammer Test (Non Destructive Test) including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours | item2 | 600 | Nos |
| 3 | 3 | Carrying out Ultrasonic Pulse Velocity test (Non Destructive Test) including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours | item3 | 600 | Nos |
| 4 | 4 | Carrying out Core Test with 40mm dia. core including all equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours. Re-filling the holes with micro concrete, finishing, etc. complete | item4 | 30 | Nos |
| 5 | 5 | Carrying out Carbonation Test including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours. | item5 | 100 | Nos |
| 6 | 6 | Carrying out Corrosion rate assessment & Half Cell potential test for steel members with all tools & tackles and as instructed by EIC | item6 | 100 | Nos |
| 7 | 7 | Carrying out Chemical analysis for PH Value, Chloride content, Sulphate content, cement content tests including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours. | item7 | 100 | Nos |
| 8 | 8 | Carrying out Ultrasonic Thickness Gauge (TG) test including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours. | item8 | 500 | Nos |
| 9 | 9 | Carrying out Transient Dynamic Response (TDR) for slab structure including all testing equipment, tools, ladders, scaffolding etc. along with technicians and skilled/unskilled labours | item9 | 50 | Nos |
| 10 | Total in Figures |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender