Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #23670180

Comprehensive Maintenance Of Daikin Air Conditioner Plant , Ac Plant Of Navajivani Hospital , Central Ac Plant With Lt Panels At Kautilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala

Issued by Statutory Bodies & Commissions/Committees · Ezhimala, Kerala
Tender Value
44 Lakhs
Estimated cost
Bid Submission
09 Mar 2020
0 days left
EMD
88000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ezhimala → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Comprehensive Maintenance Of Daikin Air Conditioner Plant , Ac Plant Of Navajivani Hospital , Central Ac Plant With Lt Panels At Kautilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala

BOQ

Name of Work: COMPREHENSIVE MAINTENANCE OF DAIKIN AC PLANT, AC PLANT OF NAVAJIVANI HOSPITAL, CENTRAL AC PLANT WITH LT PANELS AT KAUTILYA AUDITORIUM AND COLD ROOM OF LOGISTIC COMPLEX AT INA EZHIMALA
Sl.No.Description of itemItem Code / MakeQuantityUnits
11LIST OF ITEMS OF WORKS1
21.01Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 40 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the following units :- (A) LIST OF OUTDOOR UNIT :- (i) VRV Outdoor Unit 16 HP Sr. No. A000128 Located at Head Quarters Blk - 2(L/S), LVL-6 Terrace - 01 No (ii) VRV Outdoor Unit 16 HP Sr. No. A000129 Located at Head Quarters Blk - 2(L/S), LVL-6 Terrace - 01 No (iii) VRV Outdoor Unit 8 HP Sr. No. A000266 Located at Head Quarters Blk - 2(L/S), LVL-6 Terrace - 01 No (B) LIST OF ASSOCIATED INDOOR UNIT :- (i) Decorative Under type ceiling indoor 2TR Sr. No. E004791 - 01 No (ii) Decorative Under type ceiling indoor 2TR Sr. No. E004795 - 01 No (iii) Decorative Under type ceiling indoor 2TR Sr. No. E004853, E004805 - 02 Nos (iv) Decorative Under type ceiling indoor 2TR Sr. No. E004794, E004743 - 02 Nos (v) Decorative Under type ceiling indoor 2TR Sr. No. E004602, E004716 - 02 Nos (vi) Decorative Under type ceiling indoor 2TR Sr. No. E004800 - 01 No (vii) Decorative Under type ceiling indoor 2TR Sr. No. E004715, E004803, E004846 - 03 Nos (viii) Decorative Under type ceiling indoor 2TR Sr. No. E004740, E004807, E004797 - 03 Nos4JOB FOR THREE MONTHS
31.02Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 30 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the following units :- (A) LIST OF OUTDOOR UNITS :- (i) VRV Outdoor Unit 18 HP Sr. No. A001580 Located at Head Quarter Blk - 2 (L/S), LVL - 6 Terrace - 01 No (ii) VRV Outdoor Unit 12 HP Sr. No. A000440 Located at Head Quarters Blk - 2 (L/S), LVL-6 Terrace - 01 No (B) LIST OF ASSOCIATED INDOOR UNITS :- (i) Decorative Under type ceiling indoor unit 2TR Sr No. E004799, E004854, E004608 - 03 Nos (ii) Decorative Under type ceiling indoor unit 2TR Sr. No. E004739, E004786 - 02 Nos (iii) Decorative Under type ceiling indoor unit 3.2 TR Sr. No. E003032 - 01 No (iv) Decorative Under type ceiling indoor unit 2TR Sr. No. E004806 - 01 No (v) Decorative Under type ceiling indoor unit 2TR Sr. No. E004801, E004742 - 02 Nos (vi) Decorative Under type ceiling indoor unit 2TR Sr. No. E004744, E004798 - 02 Nos (vii) Decorative Under type ceiling indoor unit 2TR Sr. No. E004741 - 01 No4JOB FOR THREE MONTHS
41.03Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 46 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the following units :- (A) LIST OF OUTDOOR UNITS :- (i) VRV Out door Unit 18HP, Sr No A001601 Located at Technical Wing LHS, Blk-27, Terrace - 01 No (ii) VRV Out door Unit 18HP, Sr.No A001608 Located at Technical Wing LHS, Blk-27, Terrace - 01 No (iii) VRV Out door Unit 10HP, Sr.No A000145 Located at Technical Wing LHS, Blk-27, Terrace - 01 No (B) LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 8TR, Sr.No. A006376, A006378, A006380 - 03 Nos (ii) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005495, A005549, A005550, A005566 - 04 Nos4JOB FOR THREE MONTHS
51.04Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 46 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the the following units :- (A) LIST OF OUTDOOR UNITS :- (i) VRV Out door Unit 18HP, Sr.No. A001606 Located at Technical Wing LHS, Blk-27, Terrace - 01 No (ii) VRV Out door Unit 18HP, Sr.No. A001605 Located at Technical Wing LHS, Blk-27, Terrace - 01 No (iii) VRV Out door Unit 10HP, Sr.No. A000384.Located at Technical Wing LHS, Blk-27, Terrace - 01 No (B) LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005492 - 01 No (ii) Ductable type VRV Indoor Unit 8TR, Sr.No. A006384 - 01 No (iii) Ductable type VRV Indoor Unit 4TR, Sr.No. A006037 - 01 No (iv) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005553 - 01 No (v) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005448, A005494 - 02 Nos (vi) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005491 - 01 No4JOB FOR THREE MONTHS
61.05Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 40 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the the following units :- (A) LIST OF OUTDOOR UNITS :- (i) VRV Out door Unit 16HP Sr.No.A000133 Located at Technical Wing RHS, Blk-13, Terrace - 01 No (ii) VRV Out door Unit 16HP, Sr.No.A000134 Located at Technical Wing RHS, Blk-13, Terrace - 01 No (iii) VRV Out door Unit 8HP, Sr.No.A000248 Located at Technical Wing RHS, Blk-13, Terrace - 01 No (B) LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 4TR, Sr.No. A006043, A006039, A006044 - 03 Nos (ii) Cassette type VRV Indoor Unit 2.5TR, Sr.No. C006512, C006511, C006508 - 03 Nos (iii) Decorative Under type ceiling indoor 2TR, Sr.No. E004802, E004848, E004804, E004789 - 04 Nos (iv) Decorative Under type ceiling indoor 2TR, Sr.No. E004847, E004792, E004793, E004836 - 04 Nos4JOB FOR THREE MONTHS
71.06Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 46 HP and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the the following units :- (A) LIST OF OUTDOOR UNITS :- (i) VRV Out door Unit 18HP Sr.No.A001604. Located at Technical Wing RHS, Blk-13, Terrace - 01 No (ii) VRV Out door Unit 18HP Sr.No.A001602 Located at Technical Wing RHS, Blk-13, Terrace -01 No (iii) VRV Out door Unit 10HP Sr.No.A002603 Located at Technical Wing RHS, Blk-13, Terrace -01 No (B) LIST OF ASSOCIATED INDOOR UNITS :- (i) Ductable type VRV Indoor Unit 8TR, Sr.No. A006379 - 01 No (ii) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005485, A005498, A005493 - 03 Nos (iii) Ductable type VRV Indoor Unit 6.4TR, Sr.No. A005500, A005497, A005499 - 03 Nos4JOB FOR THREE MONTHS
81.07Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 36 HP (for every three months) and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the unit during the maintenance period of 12 months as per the manufactures instructions.Make:Mistubishi. (A) List of Out door unit :- (i) VRV Out door Unit 36HP Sr.No.4YM00378 Located at Kattari mess RHS blk Terrace - 01 No (B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.54M00615,54M00613,54M00637,54M00614,54M00617,54M00634,54M00621,54M00612- 08 Nos4JOB FOR THREE MONTHS
91.08Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 36 HP (for every three months) and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the unit during the maintenance period of 12 months as per the manufactures instructions.Make:Mistubishi. (A) List of Out door unit :- (i) VRV Out door Unit 36HP Sr.No.4YM00360 Located at Kattari mess LHS blk Terrace - 01 No (B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.54M00618,54M00624,54M00620,54M00619,54M00636,54M00616,54M00622,54M00623- 08 Nos4JOB FOR THREE MONTHS
101.09Comprehensive maintenance of variable Refrigerent Volume (VRV) outdoor unit 20 HP (for every three months) and associated indoor unit including routine preventive and immediate break down maintanance, repair and servicing as required for smooth and efficient functioning of the unit during the maintenance period of 12 months as per the manufactures instructions.Make:Mistubishi. (A) List of Out door unit :- (i) VRV Out door Unit 20HP Sr.No.4YM00364 Located at Kattari mess centre blk Terrace - 01 No (B) List of Associated indoor unit :- (i) Cassette type VRV Indoor Unit 4TR, Sr.No.47M00243,47M00377,47M00380,56M00427- 04 Nos4JOB FOR THREE MONTHS
111.1Notes for item No 1.01 to 1.09 :- Unit rates quoted by the tenderer shall be deemed to included the following :- (i) Routine services during the period. (i) Immediate attenadance and rectification of breakdown, if any. (iii) Replacement of thermistor, coil sensor, air sensor. (iv) Procurement of stationary and cleaning materials such as cotton waste clothes etc
121.11Supply and fix in replacement of compressor suitable for VRV unit complete including taking down of old compressor and required gas charging etc and testing on completion complete all as directed.3EACH
131.12Supply and fix in replacement of Invertor PCB board suitable for VRV unit complete including taking down of old PCB and required connections and testing on completion etc complete all as directed.2EACH
141.13Supply and fix in replacement of Control PCB board suitable for VRV unit complete including taking down of old PCB and required connections and testing on completion etc complete all as directed.2EACH
151.14Supply and fix in replacement of fan motor suitable for VRV unit complete including taking down of old un serviceable fan motor and required connections and testing on completion etc complete all as directed.2EACH
161.15Supply and fix high pressure switch suitable for VRV unit complete including taking down of old high pressure switch and required connections and testing on completion etc complete all as directed.2EACH
171.16Supply and fix discharge thermisture suitable for VRV unit complete including taking down of old high pressure switch and required connections and testing on completion etc complete all as directed.2EACH
181.17Supply and fix in replacement of indoor PCB board suitable for VRV unit complete including taking down of old PCB and required connections and testing on completion etc complete all as directed.2EACH
191.18Supply and fix low pressure switch suitable for VRV unit complete including taking down of old low pressure switch and required connections and testing on completion etc complete all as directed.2EACH
201.19Supply and fix in replacement indoor unit remote control suitable for VRV unit including testing complete all as directed.4EACH
211.2Comprehensive maintenance and servicing every quarterly (03 months) for the following 24 TR Air cooled scroll chiller with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenace period of 12 months and necessary periodical maintenance/checking as per the Manufacturer's instructions and as directed.. Model No XAC25-024M for the following:-
221.21Chiller 1 Sl No : 5467A E104JOB FOR THREE MONTHS
231.22Chiller 2 Sl No : 5467B E104JOB FOR THREE MONTHS
241.23Chiller 3 Sl No : 5467C E104JOB FOR THREE MONTHS
251.24Comprehensive maintenance and servicing every quarterly (03 months) for the following Bluestar walk in freezer 15000 BTU low temperature cold room with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenace period of 12 months and necessary periodical maintenance/checking as per the Manufacturer's instructions and as directed.. Model No Bluestar for following Condensing unit M/C No :-
261.25Condensing unit M/C No 13F00084, Evaporation unit M/C No 13F000944JOB FOR THREE MONTHS
271.26Condensing unit M/C No 13F00074, Evaporation unit M/C No 13F000844JOB FOR THREE MONTHS
281.27Condensing unit M/C No 13F00070, Evaporation unit M/C No 13F000924JOB FOR THREE MONTHS
291.28Comprehensive maintenance and servicing every quarterly (03 months) for the following Bluestar walk in freezer 20000 BTU high temperature cold room with microprocessor control AC plant including break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenace period of 12 months and necessary periodical maintenance/checking as per the Manufacturer's instructions and as directed.. Model No Bluestar for following Condensing unit M/C No :-
301.29Compressor sl No CD1006430479, Evaporation unit M/C No 13F000014JOB FOR THREE MONTHS
311.3Compressor sl No CB1006430503, Evaporation unit M/C No 13F000024JOB FOR THREE MONTHS
321.31Compressor sl No CC1006430508, Evaporation unit M/C No 13F000034JOB FOR THREE MONTHS
331.32Comprehensive maintenance and servicing every quarterly (03 months) for the following Bluestar two body mortuary cabinet complete with its accessoriesincluding break down maintenance as and when required, repair/replacement of defective unserviceable minor spare parts like nuts, bolts, washers, grease etc during the maintenace period of 12 months and necessary periodical maintenance/checking as per the Manufacturer's instructions and as directed.. Model No Bluestar for following Condensing unit M/C No, Model No BMC 2064JOB FOR THREE MONTHS
341.33Note for Sl item Nos 1.20 to 1.32 :- Unit rates quoted by the tenderer shall be deemed to included the following :- (i) Routine services during the period. (ii) Immediate attenadance and rectification of breakdown, if any. (iii)Checking the functioning of Chiller unit/Air Handling unit/Pumps/Controls (iv) Descaling of condensers/cleaning of evaporator coils based on our assessment and working parameters of the plant (v) Replacement of unserviceable sensors/ control boards (vi) Free repairs and replacement of defective/worn out components which are integral to the functioning of the equipment (vii)Replenishing refrigerant gas and compressor oil in the system arising out of system defect (viii) Repairs to the refrigerant pipes in case of leaks (ix) Quarterly cleaning of HEPA filters and its required repairs (x) Pumping-down and restarting as and when required (xi) Checking of Microprocessor control panel, control boards, transducers of packaged chillers/condensing unit for their correctness and replace if necessary (xii) Replacement of other unserviceable electric and mechanical parts of AC unit. (xiii) Procurement of stationary and cleaning materials such as waste cloths etc.
351.34Taking down secondary monoblock pump 5HP capacity, dismantling motor end covers, cutting and taking out burnt out stator windings complete, cleaning slots, removing diust/dirt, rewinding with the same gauge super enameled copper winding wire with insulating material, varnishing heating replacement of bearing DE and NDE ends, refixing same and ensure its serviceability complete all as specified and as directed . Model No Kirloskar KDS 536.2EACH JOB
361.35Supply and fix in replacement of compressor complete including taking down of old compressor and required gas charging etc and testing on completion complete all as directed for the following :-
371.36AC Plant 12 TR3EACH JOB
381.3715000 BTU low temperature cold room1EACH JOB
391.3820000 BTU low temperature cold room.1EACH JOB
401.39Supply and fix in replacement of control PCB circuit for 24 TR AC plant unit complete including taking down of old unserviceable PCB and testing on completion complete all as directed.1EACH JOB
411.4Supply and fix in replacement of expansion valve complete including taking down of old unserviceable expansion valve and testing on completion complete all as directed for the following:-
421.41AC Plant 24 TR1EACH JOB
431.4215000 BTU low temp cold room1EACH JOB
441.43Supply and fix in replacement of relay contactors complete including taking down of old unserviceable contactors and testing on completion complete all as directed for the following:-
451.44AC Plant 24 TR4EACH JOB
461.4515000 BTU low temp cold room1EACH JOB
471.46Supply and fix in replacement of indoor fan and fan motor set complete including taking down of old unserviceable fan and fan motor for cold room indoor unit and testing on completion complete all as directed.1EACH JOB
481.47Supply and fix in replacement of AHU air filter of following sizes :-
491.48460 mm x 610 mm x 350 mm combination filter2EACH
501.49392 mm x 542 mm x 50 mm prefilter2EACH
511.5565 mm x 460 mm x 350 mm HEPA filter2EACH
521.51Supply and charging R22 gas suitable for AC plant and cold room unit as and when required complete all as directed.40KG
531.52Supply and charging R410A gas suitable for VRV unit complete all as directed.70KG
541.53Comprehensive maintenance and servicing every quarterly (once in a three months) for the following AC Plants including breakdown maintenance as and when required/repair/replacement of defective unserviceable minor parts like nuts, bolts, washers, grease etc during the contract period of 12 months and necessary periodical maintenance/checking as per the Manufacturer's instructions and as directed by Engineer-in-Charge :- \n(i) Microprocessor based chiller water plant 200 TR (100x2) (Kautilya Auditorium AC Plant) Make :Blue Star Model:(JS 84 F-T 50 B) Equipements details :- (i) Water cooled reciprocating chiller of capacity 100 TR -02 Nos . (ii) Condenser water pump of capacity 20 HP -03 Nos. (iii) Chilled water pump primary of capacity 5 HP-03 Nos (iv) Chilled water pump secondary of cap 7.5 HP -05 Nos (v) Pump starting panel-02 Nos (vi)VFD panel -01 No (vii) Chiller starting panel-02 Nos (viii) Main LT Panel -01 No (ix) DG panel -01 No (x) Cooling tower -02 Nos (xi) Air handling units 30 TR 15000 CFM -01No (xii) Air handling unit 27.5 TR 12000 CFM-.02 Nos (xiii) Air handling unit 11.50 TR 5000 CFM -01 No (xiv) Air handling unit 30 TR 14000 CFM-01 No (xv) Air handling unit 6.5 TR 3100 CFM-01 No (Xvi) Air handling unit 9.5 TR, 4500 CFM-01 No (xvii) Air handling unit 3.5 TR, 15000 CFM-01 No4EACH JOB
551.54NOTE FOR SL ITEM NO. 1.53:-\n(a) The rate quoted shall deemed to be included the following repairs works :-\n (i) Checking and calibration of Microprocessor.\n (ii) Oiling and greasing of equipments. \n (b) The rate quoted shall deemed to be included general servicing of electrical panels and labour charges for replacement of motor starter, MCCB, MCBs, contactors, panel board rewiring with copper conductor of suitable size and copper conductor for connection to motor from starter.\n(c) The rate quoted shall deemed to be included cleaning of cooling tower minimum once in two months for smooth functioning of all AC plants.\n(d) Material required for replacement shall be measured and paid for separately under the relevant items of this BOQ as 'Supply and fix'. (e) Record of checking shall be entered in a Register as directed by Engineer-in-Charge.
561.55Supply and fix Oil pressure Transducer suitable for blue star make JS84 Compressor2EACH
571.56Supply and fix HP/LP Transducer suitable for blue star make JS84 Compressor2EACH
581.57Supply and charging compressor oil Suniso 3/4GS compressor oil after draining out old/unserviceable compressor oil complete all as directed.20LITRE
591.58Dismantling end covers of shell and tube condensor and evaporator, cleaning of copper tubes with acid / soap water with nylon brush to remove the scaling inside the tubes and ensure / confirm the flow of chilled water at head pressure within permisible limit.\n2EACH JOB
601.59Dismantling and taking down defective primary chilled water pump motor, AC, 3 phase, 415 volts of capacity 240 USGPM at 12 meter head, opening of motor end shield covers, cutting and taking out burnt out copper windings, cleaning winding slots and rewinding with super enamalled copper winding wire of suitable size and checking the continuity, insulation values, applying varnish, heating and drying and replceing the terminal block, testing complete to the entire staisfaction of Engineer-in-Charge.1EACH JOB
611.6All as per Sl item No. 1.59 above but for Secondary chilled water pump motor of capacity 288 US GPM at 20 M head for Library1EACH JOB
621.61All as per Sl item No. 1.59 above for Secondary chilled water pump motor Of capacity 240 US GPM at 15 M head for Auditorium1EACH JOB
631.62All as per Sl item No. 1.59 above for condensor water pump motor Of capacity 400 US GPM at 20 M head for Auditorium1EACH JOB
641.63Replacement of Impeller and mechanical seal for item no. 1.07 to 1.10 above all as diected.2EACH
651.64Dismantling and taking out cooling tower motor assembly, fan blade set, cooling tower fins assembly, complete cooling tower of capacity 125 TR, cleaning of cooling tower vertical FRP panels, inside and outside and bottom tank portion and removing all dirt/ dust and algae by rubbing, scrapping with nylon brush and refixing of all cooling fin assembly complete with and including applying two coats of symthetic enamel paint as per the existing color and testing and confirm the water flow rate 400 USGPM, water temp IN- 37 C/ 97.5 F and water temp OUT- 32 C/ 90 F all as directed by Engineer-in-Carge2EACH JOB
661.65Dismantling motor from floor mounted / ceiling suspended double skin horizontal AHU/Cooling tower and opening motor end shield covers cutting and taking out the burnt out copper windings, cleaning the winding slots and rewinding with super enamalled copper winding wire of suitable size and checking the continuity ,insulation values, applying varnish, heating and drying and replaceing the terminal block testingof following capacities in library and Auditorium of following capacities :-
671.66Up to 3 HP capacity1EACH JOB
681.67Above 3 HP to 5 HP1EACH JOB
691.68Above 5 HP to 7.5 HP1EACH JOB
701.69Supply and fix Fan V Belt for the FMU 7000 CFM capacity (Model 50A#)3EACH
711.7Supply and fix Fan V Belt for the FMU 8500 CFM capacity (Model 49A#)2EACH
721.71Supply and fix Fan V Belt for the FMU 9000 CFM capacity (Model 56A#2EACH
731.72Supply and fix Fan V Belt for the FMU 12000 CFM capacity (Model 66B#)2EACH
741.73Supply and fix Fan V Belt for the FMU 14000/15000 CFM capacity (Model 76B#)2EACH
751.74Supply and fix Fan V Belt for the CSU 1500 CFM capacity (Model 36B#)2EACH
761.75Supply and fix Fan V Belt for the CSU 3100 CFM capacity (Model 23B#)2EACH
771.76Supply and fix Fan V Belt for the CSU 4000 CFM capacity (Model 27B#)2EACH
781.77Supply and fix Fan V Belt for the CSU 4500/5000 CFM capacity (Model 31A#)2EACH
791.78Preparing old painted steel surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified.50SQM
801.79Taking down of expansion tank monoblock pump 1/2 HP capacity and dismantling motor end coves cutting and taking out of burnt out stator windings complete and cleaning the slots removing all dust / dirt rewinding with same guage super enamaled copper winding wire with insulating materila varnising heating replacement of bearing DE & NDE ends refixing the same and ensure its servicability complete.1EACH JOB
811.8Supply and fix MCB 4 pole 63A5EACH
821.81Supply and fix MCB 4 pole 40A4EACH
831.82Supply and fix MCB 4 pole 32A4EACH
841.83Supply and fix MCB 4 pole 25A4EACH
851.84Supply and fix DOL starter for 3 HP motor4EACH
861.85Supply and fix Single Phase preventor2EACH
871.86Supply and fix MCB SP 6-10 A5EACH
881.87Supply and fix MCB DP 6-10 A5EACH
891.88Supply and fix Ball Valve 25 mm dia2EACH
901.89Supply and fix Stem filled Alcohol Thermometer.2EACH
911.9Supply and fix Pressure gauges woth 4 inch dia 1-100 bar4EACH
921.91Supply and fix Auto Air vent of size 25 mm2EACH
931.92Supply and fix Pressure switch - Danfoss4EACH

AI Tender Summary

OUR REF NO 23670180
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 44 Lakhs
LAST DATE 09-03-2020
Authority
Authority Name Military Engineer Services
Work Description Comprehensive Maintenance Of Daikin Air Conditioner Plant , Ac Plant Of Navajivani Hospital , Central Ac Plant With Lt Panels At Kautilya Auditorium And Cold Room Of Logistic Complex At Ina Ezhimala
Basic Detail
Tender No 80401/E8
Bidding Type Tender
Location
City Ezhimala
State Kerala
Key Dates
Publish Date 18 Feb 2020
Submission Date 09 Mar 2020
Open Date 11 Mar 2020
Finance
Tender Value 44 Lakhs
Tender Fee 500
EMD 88000
Exemption Not Available
Document List
9769996_23616_19022020.pdf
Tendernotice_1.pdf
BOQ_364644.xls
D9A654CA-9287-4AE6-BACA-124F972D53A9.html
TD80401.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 01, 1900
11:30 IST

Tender Published

Tender notice published.

Completed
Mar 09, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Mar 11, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

9769996_23616_19022020.pdf

pdf

Tendernotice_1.pdf

xls

BOQ_364644.xls

html

D9A654CA-9287-4AE6-BACA-124F972D53A9.html

pdf

TD80401.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders