Beautification /Arboriclture Work At Rispana Pull To Jogiwala Chowk , Dehradun, dehradun-Uttarakhand

Mussoorie Dehradun Development Authority has published Beautification /Arboriclture Work At Rispana Pull To Jogiwala Chowk , Dehradun. Submission Date for this Tender is 28-02-2020. Earth Moving Machinery Tenders in dehradun Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

23659220
Beautification /Arboriclture Work At Rispana Pull To Jogiwala Chowk , Dehradun
Open Tender
Indian
Uttarakhand
dehradun
28-02-2020

Tender Details

Beautification /Arboriclture Work At Rispana Pull To Jogiwala Chowk , Dehradun , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1 . 5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms , Lift Upto 1 . 5 M , Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M . All Kinds Of Soil . , Filling Available Excavated Earth ( Excluding Rock ) In Trenches , Plinth , Sides Of Foundations Etc . In Layers Not Exceeding 20Cm In Depth , Consolidating Each Deposited Layer By Ramming And Watering , Lead Up To 50 M And Lift Upto 1 . 5 M . , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . , Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters , Buttresses , Plinth And String Courses , Fillets , Columns , Pillars , Piers , Abutments , Posts And Struts Etc . Above Plinth Level Up To Floor Five Level , Excluding Cost Of Centering , Shuttering , Finishing And Reinforcement : 1:1 . 5:3 ( 1 Cement : 1 . 5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Steel Reinforcement For R . C . C . Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Level . 5 . 22 . 6 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More . , Silicon Coating Of Stone Cladding From Outside , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 7 . 5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 7 . 5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Providing And Fixing 40 Mm Thick I- In Red Sand Stone Masonary Wet Clading In 1:4 Complete In All Repect As Direction Of Engineer Incharge . , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :13 . 2 . 2 1:6 ( 1 Cement: 6 Fine Sand ) , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters , Vanities Etc . , Including Machine Polishing To Edge To Give High Gloss Finish Etc . Complete As Per Design Approved By Engineer-In-Charge . 8 . 3 . 2 Granite Work , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge . 15 . 7 . 4 In Cement Mortar Cum 842 . 75 , Horticulture Work Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge :15 . 9 . 2 In Cement Mortar C , Providing And Displaying Of Clerodendron Inerme Plant Having Ht . 25 Cm To 32 Cm Multi Branched In 20 Cm Size Of Earthen Pot / Plastic Pot & As Per Direction Of The Officer-In-Charge . , Plantation Of Trees , Shrubs And Hedge Site I/C Watering And Removel Of Underveiceable Material As Per Direction Of Officers In Charge ( Excluding Cast Of Plant &Water ) Shrubs Plant Ht . 75Cmto 90Cm , Supply 7 Stacking Of Plants At Site Fresh & Free From Weeds Having Proper Roots In Green Including Loading /Unloding /Carriage And All Taxes Paid Etc . And As Per Direction Of Officers In Charge , Supplying And Stacking At Site . Good Earth , External Lighting: Feeder Pillars: Design , Manufacture , Supply , Installation , Testing And Commissioning Of Follwing Feeder Pillars Suitable For 415 V , 3 Phase , 4 Wire , 50 Hz Power Distribution System . The Panel Shall Be Weather Proof , Ip-55 , From-1 . Double Door Construction Suitable For Outdoor Application , Free Standing , Peadestal Mounting , Sheet Metal Clad , Cubicle , Dead Front , Dust And Vermin Proof Type Compartmentalised Design Fabricated Out Of 14 Swg ( 2Mm ) Crca Sheet Steel , Complete With Colour Coded , Heat Shrinkable Pvc Insulated , Aluminium Bus Bars And Separate Earth Bus Bar Of Adequate Cross Section Through Out The Length Of The Panel . The Incoming And Outgoing Feeders Shall Be Accommodated With Adequate Size And Distinct Cable Alley , Bus Bar Alley/Chamber . The Panel Shall Be Complete With Name Plate , Earthing , Numbering , Danger Plate Etc . As Required And As Per Specifications And Drawings . , The Boq Shall Be Read Inconjunction With General Notes . Specification And Single Line Diagram ( Attached For Ref . ) Incase Of Any Discrepancy Between Specification , Boq And Sld , The Same Shall Be Brought To The Notice Of Client/Consultant Before Quoting The Rates , Otherwise Stringent Condition Shall Be Deemed To Have Been Considered . , Fault Current Wherever Mentioned Shall Be Lcs Value . , All Mccb Shall Be Provided With Door Interlocked Rotary Handle With On/Trip/Off Position Indicator , Continious Variable Thermal Magnetic O/C And S/C Raleases . I/C Mccb Shall Be Provided With E/F Release/Protection Also . , All Feeder Pillars Shall Be Ip-55 And Doors Shall Have Pad Locking Arrangement . , All Tp Feeders Shall Have Solid Isolable Neutral Link . , All Power Contactors Including Nic Shall Be Of Ac3 Duty . , Spare Contacts Of Relays/Contactor Etc . Shall Be Wired Upto Terminal Block . , All Outgoing Terminals ( Power And Control ) Shall Be Brought Upto Cable Alley . 10% Extra Terminals Shall Be Provided . , 10% Extra Indicating Lamp In Loose Shall Be Supplied Along With Panel . , Removable Lifting Hook Shall Be Provided In All Transportation Section . , All Ct , Pt Shall Be Cast Resin . , All Meters Are Digital Type . , Panel Shall Be Powder Coated Of Approved Shade With Minimum 60 Micron Thickness . , Size Of Voltmeter / Ammeter For Incomer Also , 96Mm X 96Mm Flush Mounted With Shrouded Terminal Shall Be Used In The Panel . , Bus Bar Chamber Shall Be Kept At Top Of The All Panels . , All Bus Bar Shall Be Insulated With Coloured Pvc Sleeve Ie Ryb , Bk As Per Colour Code . , Internal Wiring Of Panel Shall Be With Size 2 . 5Sqmm Flexible Copper Conductor For Ct Circuit And Control Wiring With 1 . 5Sqmm . , All Indicating Light Shall Be Led Type . , Each Verticla Section Of Floor Mounted Panel Shall Have Independent Base Frame ( 75Mm X 40Mm ) Size Made Out Of 3Mm Sheet Steel ( Lt Panel & Dg Panel ) . , All The Makes Shall Be As Per Client Approved Make List Only . , Wherever Only Voltmeter & Ammeter Are Required The Same May Be Provided In Combined Meter Suitable For Both Parameter . , Feeder Pillars Shall Be Provided With The 230V Operated , Door Switch Controlled , Panel Illumination Lamps And Thermostat Controlled Space Heater . , Foundations For Feeder Pillars Shall Be Provided By The Client , Form Other Agency , As Per Approved Ga Drawing Provided By The Vendor . , Feeder Pillars : Fp # 1 ( Weather Proof ) , Incomer:63A 4P Mcb With Dp Elcb ( 100Ma ) For Each Phase , Three ( 3 ) Nos . 63A Dp Contactor ( Ac 3 Duty With 230V Control Coil ) , Ree ( 3 ) Nos . 24 Hour Double Dial Programmable Time Switch On Auto Mode Arrangement For Auto/Manual Selection , Push Buttons , Indication Lamps & Control Fuses Etc As Per Drawings And As Required , One ( 1 ) No . Mushroom Head Type Emergency Stop Push Button With Under Voltage Release , Busbar , 100A 4P Al Busbar , Outgoi

Key Value

Document Fees
INR 5000 /-
EMD
INR 358000.0 /-
Tender Value
INR 1.74 Crore /-

BOQ Items

Name of Work: Beautification /Arboriclture work at Rispana pull to jogiwala chowk ,Dehradun
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. BI01010001010000000000000515BI0100001113 742.5 Nos
2 1.02 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. BI01010001010000000000000515BI0100001114 148.5 Nos
3 1.03 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001115 167.06 Nos
4 1.04 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001116 34.59 Nos
5 1.05 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001117 37.95 Nos
6 1.06 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. BI01010001010000000000000515BI0100001118 4468.61 Nos
7 1.07 Silicon coating of stone cladding from outside BI01010001010000000000000515BI0100001119 742.5 Nos
8 1.08 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001120 132.83 Nos
9 1.09 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) BI01010001010000000000000515BI0100001121 174.99 Nos
10 1.1 Providing and fixing 40 mm thick i- in red Sand stone masonary wet clading in 1:4 complete in all repect as direction of engineer incharge. BI01010001010000000000000515BI0100001122 771.7 Nos
11 1.11 15 mm cement plaster on the rough side of single or half brick wall of mix :13.2.2 1:6 (1 cement: 6 fine sand) BI01010001010000000000000515BI0100001123 771.71 Nos
12 1.12 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.8.3.2 Granite work BI01010001010000000000000515BI0100001124 3300 Nos
13 1.13 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.15.7.4 In cement mortar cum 842.75 BI01010001010000000000000515BI0100001125 36.64 Nos
14 1.14 Horticulture work Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :15.9.2 In cement mortar c BI01010001010000000000000515BI0100001126 34.67 Nos
15 1.15 Providing and Displaying of Clerodendron inerme plant having ht. 25 cm to 32 cm multi branched in 20 cm size of Earthen Pot / Plastic Pot & as per direction of the officer-in-charge. BI01010001010000000000000515BI0100001127 10700 Nos
16 1.16 PLANTATION OF TREES ,SHRUBS AND HEDGE SITE i/c watering and removel of underveiceable material as per direction of officers in charge (excluding cast of plant &water)shrubs plant ht. 75cmto 90cm BI01010001010000000000000515BI0100001128 1992 Nos
17 1.17 Supply 7 Stacking of plants at site fresh & free from weeds having proper roots in green including loading /unloding /carriage and all taxes paid etc. and as per direction of officers in charge BI01010001010000000000000515BI0100001129 802.5 Nos
18 1.18 Supplying and stacking at site. GOOD EARTH BI01010001010000000000000515BI0100001130 321.88 Nos
19 1.19 EXTERNAL LIGHTING: FEEDER PILLARS: Design, manufacture, supply, Installation, testing and Commissioning of follwing feeder Pillars suitable for 415 V, 3 Phase, 4 wire, 50 Hz Power distribution system. The panel shall be weather Proof, IP-55, From-1. Double Door Construction suitable for outdoor application, free standing, peadestal mounting, sheet metal clad, cubicle, dead front, dust and vermin proof type compartmentalised design fabricated out of 14 SWG(2mm) CRCA sheet steel, complete with colour coded, heat shrinkable PVC insulated, aluminium bus bars and separate earth bus bar of adequate cross section through out the length of the panel. The incoming and outgoing feeders shall be accommodated with adequate size and distinct cable alley, bus bar alley/chamber. The panel shall be complete with name plate, earthing, numbering, danger plate etc. as required and as per specifications and drawings. BI01010001010000000000000515BI0100001131 1 Nos
20 1.2 The BOQ Shall be read inconjunction with general notes. Specification and Single Line Diagram (attached for Ref.) Incase of any discrepancy between specification, BOQ and SLD, the same shall be brought to the notice of Client/Consultant before quoting the rates, otherwise stringent condition shall be deemed to have been considered. BI01010001010000000000000515BI0100001132 1 Nos
21 1.21 Fault current wherever mentioned shall be lcs value. BI01010001010000000000000515BI0100001133 1 Nos
22 1.22 All MCCB shall be provided with door interlocked rotary handle with ON/TRIP/OFF position indicator, continious variable thermal magnetic O/C and S/C raleases. I/C MCCB shall be provided with E/F release/protection also. BI01010001010000000000000515BI0100001134 1 Nos
23 1.23 All Feeder Pillars shall be IP-55 and doors shall have pad locking arrangement. BI01010001010000000000000515BI0100001135 1 Nos
24 1.24 All TP feeders shall have solid isolable neutral link. BI01010001010000000000000515BI0100001136 1 Nos
25 1.25 All power contactors including NIC shall be of AC3 duty. BI01010001010000000000000515BI0100001137 1 Nos
26 1.26 Spare contacts of Relays/Contactor etc. shall be wired upto terminal block. BI01010001010000000000000515BI0100001138 1 Nos
27 1.27 All outgoing terminals (Power and control) shall be brought upto cable alley. 10% extra terminals shall be provided. BI01010001010000000000000515BI0100001139 1 Nos
28 1.28 10% extra indicating lamp in loose shall be supplied along with panel. BI01010001010000000000000515BI0100001140 1 Nos
29 1.29 Removable lifting hook shall be provided in all transportation section. BI01010001010000000000000515BI0100001141 1 Nos
30 1.3 All CT, PT shall be cast resin. BI01010001010000000000000515BI0100001142 1 Nos
31 1.31 All meters are digital type. BI01010001010000000000000515BI0100001143 1 Nos
32 1.32 Panel shall be powder coated of approved shade with minimum 60 micron thickness. BI01010001010000000000000515BI0100001144 1 Nos
33 1.33 Size of voltmeter / Ammeter for incomer also, 96mm x 96mm flush mounted with shrouded terminal shall be used in the panel. BI01010001010000000000000515BI0100001145 1 Nos
34 1.34 Bus bar chamber shall be kept at top of the all panels. BI01010001010000000000000515BI0100001146 1 Nos
35 1.35 All bus bar shall be insulated with coloured PVC Sleeve ie RYB, BK as per colour code. BI01010001010000000000000515BI0100001147 1 Nos
36 1.36 Internal wiring of panel shall be with size 2.5sqmm Flexible copper Conductor for CT circuit and control wiring with 1.5sqmm. BI01010001010000000000000515BI0100001148 1 Nos
37 1.37 All indicating light shall be LED type. BI01010001010000000000000515BI0100001149 1 Nos
38 1.38 Each verticla section of floor mounted panel shall have independent base frame (75mm x 40mm) size made out of 3mm sheet steel (LT Panel & DG Panel). BI01010001010000000000000515BI0100001150 1 Nos
39 1.39 All the makes shall be as per Client approved make list only. BI01010001010000000000000515BI0100001151 1 Nos
40 1.4 Wherever only voltmeter & ammeter are required the same may be provided in combined meter suitable for both parameter. BI01010001010000000000000515BI0100001152 1 Nos
41 1.41 Feeder Pillars shall be provided with the 230V operated, Door switch controlled, panel illumination Lamps and thermostat controlled space heater. BI01010001010000000000000515BI0100001153 1 Nos
42 1.42 Foundations for feeder pillars shall be provided by the client, form other agency, as per approved GA drawing provided by the vendor. BI01010001010000000000000515BI0100001154 1 Nos
43 1.43 Feeder Pillars : FP # 1 (Weather Proof),Incomer:63A 4P MCB with DP ELCB (100mA) for each phase,Three (3) Nos. 63A DP Contactor (AC 3 Duty with 230V Control Coil) , ree (3) Nos. 24 hour double dial programmable time switch on Auto mode arrangement for Auto/Manual selection, Push Buttons, indication lamps & Control fuses etc as per drawings and as required , One (1) No. Mushroom head type emergency stop push button with under voltage release, Busbar, 100A 4P Al busbar,Outgoing ,16A DP MCBs - 5 Nos., 25A DP MCBs - 5 Nos., 32A DP MCBs - 5 Nos. , CABLES :, Cables in under Ground Installations : BI01010001010000000000000515BI0100001155 1 Set
44 1.44 Supply, installation, testing and commissioning of following sizes of PVC Sheathed XLPE Insulated aluminium conductor / Copper conductor Power/multicore control armoured cable of 1.1 KV grade in ground including digging the trench, laying the cable with sand and brick covering, back filling etc as required. BI01010001010000000000000515BI0100001156 1 Nos
45 1.45 4 C x 10 Sqmm BI01010001010000000000000515BI0100001157 500 Rm
46 1.46 4 C x 16 Sqmm BI01010001010000000000000515BI0100001158 550 Rm
47 1.47 4 C x 6 Sqmm BI01010001010000000000000515BI0100001159 50 Rm
48 1.48 2 C x 6 Sqmm BI01010001010000000000000515BI0100001160 25 Rm
49 1.49 Cable Termination BI01010001010000000000000515BI0100001161 1 Nos
50 1.5 Supply and making end temination with brass double compression glands for the following XLPE insulated PVC sheathed 1100 V grade cable including cost of crimping lugs/ferrules, compression glands, solder, cable sockets, insulation tap etc complete as required. BI01010001010000000000000515BI0100001162 1 Nos
51 1.51 4 C x 10 Sqmm BI01010001010000000000000515BI0100001163 100 Nos
52 1.52 4 C x 16 Sqmm BI01010001010000000000000515BI0100001164 250 Nos
53 1.53 4 C x 6 Sqmm BI01010001010000000000000515BI0100001165 10 Nos
54 1.54 2 Core 6 Sqmm BI01010001010000000000000515BI0100001166 5 Nos
55 1.55 The cable quantities given are approximate and to cover various sizes. The contractor shall measure the cables required and procurement order shall be placed accordingly. The quantities shall be confirmed before start of work. BI01010001010000000000000515BI0100001167 1 Nos
56 1.56 Hume / HDPE Pipes Installation BI01010001010000000000000515BI0100001168 1 Nos
57 1.57 Supply and Installation of following sizes of NP-3 grade hume pipes for road crossings, paved areas etc including collars and misc. Jointing accessories, digging the trench, back filling etc complete in all respect as required. BI01010001010000000000000515BI0100001169 1 Nos
58 1.58 150 mm dia BI01010001010000000000000515BI0100001170 12 Rm
59 1.59 100 mm dia BI01010001010000000000000515BI0100001171 3 Rm
60 1.6 Supply and Installation of following sizes of HDPE bendable pipes for road crossings, paved areas etc including all accessories, Junction, Pull box bends and misc. Jointing Accessories, digging the trench, back filling etc complete in all respect as required. BI01010001010000000000000515BI0100001172 1 Nos
61 1.61 100 mm dia BI01010001010000000000000515BI0100001173 200 Rm
62 1.62 PVC Conduit Installation : BI01010001010000000000000515BI0100001174 1 Nos
63 1.63 Supply and installation of following sizes of 16G thick PVC conduit including all accessories. BI01010001010000000000000515BI0100001175 1 Nos
64 1.64 25 mm dia PVC Conduit BI01010001010000000000000515BI0100001176 220 Rm
65 1.65 EARTHING : BI01010001010000000000000515BI0100001177 1 Nos
66 1.66 Earthing Stations : BI01010001010000000000000515BI0100001178 1 Nos
67 1.67 Supply, installation, testing and commissioning of GI Pipe earthing stations making earth pits, earthing with 40 dia 3.5 m long G.I. earth pipe including discon-necting /testing links etc as required. (For body panel earthing & Pole earthing) BI01010001010000000000000515BI0100001179 2 Nos
68 1.68 Earthing Strip/Wires - Supply installation, testing and commissioning of following size of G.I. Strip direct in ground as per specification for connecting to various earthing station, grounding mat etc including interconnections, digging, back filling complete as required. BI01010001010000000000000515BI0100001180 1 Nos
69 1.69 25 x 3 mm strip BI01010001010000000000000515BI0100001181 12 Nos
70 1.7 8 SWG wire BI01010001010000000000000515BI0100001182 80 Nos
71 1.71 Supply and fixing in plants in exsiting light pole BI01010001010000000000000515BI0100001183 54 Nos
72 1.72 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade for exsiting street light pole. BI01010001010000000000000515BI0100001184 54 Nos
73 1.73 Providing and fixing 40mm thick in red sand stone masonary wet cladding in 1:4 complete in all respect as per direction of engineer incharge BI01010001010000000000000515BI0100001185 53 Cum
74 1.74 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) BI01010001010000000000000515BI0100001186 14.92 Cum
75 1.75 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). BI01010001010000000000000515BI0100001187 14.92 Cum
76 1.76 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. BI01010001010000000000000515BI0100001188 1171.33 Sqm
77 1.77 7.1 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 7.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 3965.85. BI01010001010000000000000515BI0100001189 44.76 Cum
78 1.78 Supplying inspection, receiving, storing, handling, assembiling. Installation, testing and commissioning of Outdoor type, pole mounted/wall mounted, surface/recessed type HPSV/Metal Halide / LED/ Halogen lamp fixtures including making connections with PVC/XLPE insulated stranded copper/aluminium conductor wires complete including steel supports, suspenders, fixing screws, turn buckles, bolts, nuts etc, as required. The Mounting arrangement of lighting fixture shall be as per approved shop drawings. BI01010001010000000000000515BI0100001190 1 Nos
79 1.79 Lighting Fixture : 50 W decorative light fixture for temple. BI01010001010000000000000515BI0100001191 190 Nos
80 1.8 Wiring for Temple Light:Wiring of light point with FR PVC Insulated 1.5 sq.mm stranded copper conductor wires & earth with 1.5 sq.mm FR PVC insulated CU. Conductor from Pole Junction Box to the light fixture complete in all respects including testing and commissioning as required. BI01010001010000000000000515BI0100001192 1 Nos
81 1.81 2 x 1.5 sq.mm + 1 x 1.5 sq.mm copper earth wire BI01010001010000000000000515BI0100001193 1000 Rm
82 1.82 Supplying, receiving, storing, handling, assembling, installation, testing and commissioning of Outdoor type, pole mounted/wall mounted, surface/recessed type GI power coted junction box for cable termination complete with supports, fixing screws, bolts, nuts etc, as required. The mounting arrangement of junction box shall be as per approved shop drawings. BI01010001010000000000000515BI0100001194 160 Nos
83 1.83 EARTHING : BI01010001010000000000000515BI0100001195 1 Nos
84 1.84 Earthing Stations : BI01010001010000000000000515BI0100001196 1 Nos
85 1.85 Supply, installation, testing and commissioning of GI Pipe earthing stations making earth pits, earthing with 40 dia 3.5 m long G.I. earth pipe including discon-necting /testing links etc as required. (For body panel earthing & Pole earthing) BI01010001010000000000000515BI0100001197 12 Nos
86 1.86 Earthing Strip/Wires BI01010001010000000000000515BI0100001198 1 Nos
87 1.87 Supply installation, testing and commissioning of following size of G.I. Strip direct in ground as per specification for connecting to various earthing station, grounding mat etc including interconnections, digging, back filling complete as required. BI01010001010000000000000515BI0100001199 1 Nos
88 1.88 25 x 3 mm strip BI01010001010000000000000515BI0100001200 205 Rm
89 1.89 8 SWG wire BI01010001010000000000000515BI0100001201 500 Rm
90 1.9 Supplying and fixing of following ways surface/recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required. ) 4 Way (4 + 12 ), Double door (DSR 2016 2.5.1) BI01010001010000000000000515BI0100001202 190 Nos
91 1.91 Supplying and fixing 5A to 32A rating, 240/415 V, 10KA, "C" curve. Miniature circuit breaker suitable for inductive load of following poles in the exiting MCB DB complete with connections, testing and commissioning etc. as required. ( DSR 2016 2.10 ) BI01010001010000000000000515BI0100001203 190 Nos
92 1.92 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR 2016 2.13.3 ) BI01010001010000000000000515BI0100001204 190 Nos