Beautification /Arboriclture Work At Rispana Pull To Jogiwala Chowk , Dehradun , Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1 . 5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms , Lift Upto 1 . 5 M , Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed , Within A Lead Of 50 M . All Kinds Of Soil . , Filling Available Excavated Earth ( Excluding Rock ) In Trenches , Plinth , Sides Of Foundations Etc . In Layers Not Exceeding 20Cm In Depth , Consolidating Each Deposited Layer By Ramming And Watering , Lead Up To 50 M And Lift Upto 1 . 5 M . , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) , 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 20 Mm Nominal Size ) . , Reinforced Cement Concrete Work In Walls ( Any Thickness ) , Including Attached Pilasters , Buttresses , Plinth And String Courses , Fillets , Columns , Pillars , Piers , Abutments , Posts And Struts Etc . Above Plinth Level Up To Floor Five Level , Excluding Cost Of Centering , Shuttering , Finishing And Reinforcement : 1:1 . 5:3 ( 1 Cement : 1 . 5 Coarse Sand ( Zone-Iii ) : 3 Graded Stone Aggregate 20 Mm Nominal Size ) . , Steel Reinforcement For R . C . C . Work Including Straightening , Cutting , Bending , Placing In Position And Binding All Complete Upto Plinth Level . 5 . 22 . 6 Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More . , Silicon Coating Of Stone Cladding From Outside , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 7 . 5 In Foundation And Plinth In: Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Brick Work With Common Burnt Clay F . P . S . ( Non Modular ) Bricks Of Class Designation 7 . 5 In Superstructure Above Plinth Level Up To Floor V Level In All Shapes And Sizes In :Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) , Providing And Fixing 40 Mm Thick I- In Red Sand Stone Masonary Wet Clading In 1:4 Complete In All Repect As Direction Of Engineer Incharge . , 15 Mm Cement Plaster On The Rough Side Of Single Or Half Brick Wall Of Mix :13 . 2 . 2 1:6 ( 1 Cement: 6 Fine Sand ) , Providing Edge Moulding To 18 Mm Thick Marble Stone Counters , Vanities Etc . , Including Machine Polishing To Edge To Give High Gloss Finish Etc . Complete As Per Design Approved By Engineer-In-Charge . 8 . 3 . 2 Granite Work , Demolishing Brick Work Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge . 15 . 7 . 4 In Cement Mortar Cum 842 . 75 , Horticulture Work Demolishing Stone Rubble Masonry Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge :15 . 9 . 2 In Cement Mortar C , Providing And Displaying Of Clerodendron Inerme Plant Having Ht . 25 Cm To 32 Cm Multi Branched In 20 Cm Size Of Earthen Pot / Plastic Pot & As Per Direction Of The Officer-In-Charge . , Plantation Of Trees , Shrubs And Hedge Site I/C Watering And Removel Of Underveiceable Material As Per Direction Of Officers In Charge ( Excluding Cast Of Plant &Water ) Shrubs Plant Ht . 75Cmto 90Cm , Supply 7 Stacking Of Plants At Site Fresh & Free From Weeds Having Proper Roots In Green Including Loading /Unloding /Carriage And All Taxes Paid Etc . And As Per Direction Of Officers In Charge , Supplying And Stacking At Site . Good Earth , External Lighting: Feeder Pillars: Design , Manufacture , Supply , Installation , Testing And Commissioning Of Follwing Feeder Pillars Suitable For 415 V , 3 Phase , 4 Wire , 50 Hz Power Distribution System . The Panel Shall Be Weather Proof , Ip-55 , From-1 . Double Door Construction Suitable For Outdoor Application , Free Standing , Peadestal Mounting , Sheet Metal Clad , Cubicle , Dead Front , Dust And Vermin Proof Type Compartmentalised Design Fabricated Out Of 14 Swg ( 2Mm ) Crca Sheet Steel , Complete With Colour Coded , Heat Shrinkable Pvc Insulated , Aluminium Bus Bars And Separate Earth Bus Bar Of Adequate Cross Section Through Out The Length Of The Panel . The Incoming And Outgoing Feeders Shall Be Accommodated With Adequate Size And Distinct Cable Alley , Bus Bar Alley/Chamber . The Panel Shall Be Complete With Name Plate , Earthing , Numbering , Danger Plate Etc . As Required And As Per Specifications And Drawings . , The Boq Shall Be Read Inconjunction With General Notes . Specification And Single Line Diagram ( Attached For Ref . ) Incase Of Any Discrepancy Between Specification , Boq And Sld , The Same Shall Be Brought To The Notice Of Client/Consultant Before Quoting The Rates , Otherwise Stringent Condition Shall Be Deemed To Have Been Considered . , Fault Current Wherever Mentioned Shall Be Lcs Value . , All Mccb Shall Be Provided With Door Interlocked Rotary Handle With On/Trip/Off Position Indicator , Continious Variable Thermal Magnetic O/C And S/C Raleases . I/C Mccb Shall Be Provided With E/F Release/Protection Also . , All Feeder Pillars Shall Be Ip-55 And Doors Shall Have Pad Locking Arrangement . , All Tp Feeders Shall Have Solid Isolable Neutral Link . , All Power Contactors Including Nic Shall Be Of Ac3 Duty . , Spare Contacts Of Relays/Contactor Etc . Shall Be Wired Upto Terminal Block . , All Outgoing Terminals ( Power And Control ) Shall Be Brought Upto Cable Alley . 10% Extra Terminals Shall Be Provided . , 10% Extra Indicating Lamp In Loose Shall Be Supplied Along With Panel . , Removable Lifting Hook Shall Be Provided In All Transportation Section . , All Ct , Pt Shall Be Cast Resin . , All Meters Are Digital Type . , Panel Shall Be Powder Coated Of Approved Shade With Minimum 60 Micron Thickness . , Size Of Voltmeter / Ammeter For Incomer Also , 96Mm X 96Mm Flush Mounted With Shrouded Terminal Shall Be Used In The Panel . , Bus Bar Chamber Shall Be Kept At Top Of The All Panels . , All Bus Bar Shall Be Insulated With Coloured Pvc Sleeve Ie Ryb , Bk As Per Colour Code . , Internal Wiring Of Panel Shall Be With Size 2 . 5Sqmm Flexible Copper Conductor For Ct Circuit And Control Wiring With 1 . 5Sqmm . , All Indicating Light Shall Be Led Type . , Each Verticla Section Of Floor Mounted Panel Shall Have Independent Base Frame ( 75Mm X 40Mm ) Size Made Out Of 3Mm Sheet Steel ( Lt Panel & Dg Panel ) . , All The Makes Shall Be As Per Client Approved Make List Only . , Wherever Only Voltmeter & Ammeter Are Required The Same May Be Provided In Combined Meter Suitable For Both Parameter . , Feeder Pillars Shall Be Provided With The 230V Operated , Door Switch Controlled , Panel Illumination Lamps And Thermostat Controlled Space Heater . , Foundations For Feeder Pillars Shall Be Provided By The Client , Form Other Agency , As Per Approved Ga Drawing Provided By The Vendor . , Feeder Pillars : Fp # 1 ( Weather Proof ) , Incomer:63A 4P Mcb With Dp Elcb ( 100Ma ) For Each Phase , Three ( 3 ) Nos . 63A Dp Contactor ( Ac 3 Duty With 230V Control Coil ) , Ree ( 3 ) Nos . 24 Hour Double Dial Programmable Time Switch On Auto Mode Arrangement For Auto/Manual Selection , Push Buttons , Indication Lamps & Control Fuses Etc As Per Drawings And As Required , One ( 1 ) No . Mushroom Head Type Emergency Stop Push Button With Under Voltage Release , Busbar , 100A 4P Al Busbar , Outgoi