Provision Of Deficient Equipment Lift At Arsr Main Tower At Ins Hansa Under Ge Nw Vasco

Tender Notice

23652634
Provision Of Deficient Equipment Lift At Arsr Main Tower At Ins Hansa Under Ge Nw Vasco
Indian
Goa
02-04-2020
23-04-2020
25-04-2020

Tender Details

Provision Of Deficient Equipment Lift At Arsr Main Tower At Ins Hansa Under Ge Nw Vasco

Corrigendum Details

Sr No CorrigendumDate Description Submission Date
1 14-03-2020 DATE CORRGENDUM 30-03-2020
2 23-03-2020 DATE CORRIGENDUM 2 13-04-2020
3 02-04-2020 DATE CORRIGENDUM 3 23-04-2020

Key Value

Document Fees
INR 1000 /-
EMD
INR 162000.00 /-
Tender Value
INR 81.70 Lakhs /-

Attachment

FileName File Description File Size
85088TestingFINAL.pdf Tender Document-TESTING 127.43
BOQ_364176.xls Tender Document-BOQ 345.00
85088SCHPART2.pdf Tender Document-SCH PART 2 106.49
85088SCHPART1.pdf Tender Document-SCH PART 1 8.34
0193FC0F-174F-4CAA-B601-AA17B66340B1.html Tender Notice-Tender Notice 0
85088DRGS.rar Tender Document-DRGS 7212.46
Tendernotice_1.pdf Tender Document-NOT 383.28
85088ETender.pdf Tender Document-TENDER DOCUMENTS 1276.58

Other Information

Attachments
Additional Details Available on Click
✓ Tendering Authority
✓ Publication Document
(Tender Document / Tender Notice )

BOQ Items

Name of Work: PROVISION OF DEFICIENT EQUIPMENT LIFT AT ARSR MAIN TOWER AT INS HANSA UNDER GE (NW) VASCO
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Total amount of Sch 'A' Part-I (BUILDING and STRUCTURES) brought forward from Serial Page No.25\n 1 Lump sum
2 2 Total amount of Sch 'A' Part-II (ELECTRIFICATION) brought forward from Serial Page No.29 1 Lump sum
3 3 Sch 'A' Part- III - MISCELLANEOUS ITEMS \nNote : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
4 3.001 Electrification
5 3.01 Design supply, install, testing & commissioning goods lift (15 Person) 1020 Kg , speed 1.5 metre/sec, including with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve upto 6 floors (G+5 floors) upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set complete all as specified and as directed.\nMake :- OTIS/Thyssen Krupp/ Schineler 1 Each
6 3.011 (a ) Capacity (kgs) :- 1020 Kg, 15 persons\n(b) Speed (mps) :- 1.5 mps \n( c) Rise (m) :- 22.6 m \n(d) Stops :- 3 Stops (One entrance at Ground floor & 5th and 6th Floor & one Dummy Landing) \n(e) Controller Type :- LVA/ACD\n(f) Drive :- VF Regenerative (Closed Loop) \n(g) Power Supply :- 400/415 Volts (3 Phase AC) \n(h) Operation :- Full collective operation \n(j) Car group :- One car (simplex) \n(k) Machine :- PM Gearless (Located in shaft on top of guide rails) \n(l) Traction media :- Flat Coated Steel Belt
7 3.012 (m) Car Finish :- \n(i) Rear Mid Panel = Stainless steel (finish-SS-304) (ii) Rear Corner Panels = Stainless steel (finish-SS-304) (iii) Side Mid Panels = Stainless steel (finish-SS-304) (iv) Side Corner Panels = Stainless steel (Hairline) (v) Front Panels = Stainless steel (Hairline\n(n) False ceiling type :- CD-41 \n(o) False ceiling finish :-Stainless Steel (Hairline) \n(p ) Ventillation :- Cross flow fan \n(q) Hand Rails :- Stainless Steel Mirror Finish Handrails on rear car panels (side LH, side RH&Rear)\n\n
8 3.013 (r) Flooring :- Aluminum Chequered plate\n(s) Car door finish :- Stainless steel (finish-SS-304) \n(t) Landin door finish :- Stainless steel (finish-SS-304) \n(u) Fire rated doors :- Fire rating-60mins\n(v) Pit depth :- 1600\n(w) Overhead :- OVERHEAD 4500 mm\n(x) Hoistway dimensions (W x D – mm) :- 2200 mm W x 2500 mm D \n(y) Car dimensions (W x D x H - mm) :- 1200 mm W x 2000 mm D x 2300 mm D \n(z) Car & hoistway door type :- Central opening (CO) doors
9 3.014 (aa) Door openign (W x H - mm) :- 900 mm W x 2100 mm H \n(ab) Door operator :- DC Door Operator \n (ac) Cop[ :- COP for stops <= 12 (950mm) in Stainless Steel (Hairline)\n(ad) Car position indicator :- Monochrome LCD-Blue Background & Blue font \n(ae) Hall fixtures :- O2000 \n(af) Hall fixture face plate :- Stainless Steel (Hairline) \n(ag) Hall button Arrangement :- Hall Button with HPI\n
10 3.015 (ah) Standard Features :- Anti-nuisance Car Call Protection Independent Service (for Duplex only), Overload, Device, Nudging, Emergency Firemen’s Service Emergency Car Light Unit Infrared Curtain Door Protection, Door Time Protection, Emergency Alarm Button, Extra Door Time of Lobby & Parking, Door Open/Close Button, Manual Rescue Operation, Belt Inspection Drive, Auto Fan Cut Off \n(aj) Options Included :- Automatic Rescue Operation Intercom\n(ak) Provision of emergency key opening at all landings.\n(al) PVC insulated, multistranded sheathes flexible 1100V grade cooper conductor cable suitable for 3 phase, 415 V multi core cable from ground floor to lift machine room for lift controller and gear motor and single phase 240V copper conductor cable from ground floor to lift machine room for car heihts, hoist way light, machine room light complete with including switch gear items and RCBO/MCBs etc in suitable sheet steel eclosure.\n
11 3.016 Notes :- The following works are deemed to be included in rate quited by the contractor.\n(i) Any accessories/items/safty devices required to be installed and not coverd in schedule are to be provided by contractor without extra cost.\n(ii) Testing of lift shall got through a Govt Lift Inspector (Goa State) and necessary certificate to be obtained by the contractor and produced to the Garrison Engineer.
12 3.02 Supply and fix retrofit LED bulb 9W 240volts,50Hz, complete all as specified and directed. 7 Each
13 3.03 Supply, laying, testing and commissioning LT Cable XLPE insulated, galvanised steel strip armoured,1100 volts grade, multistranded copper conductor cable of cross sectional area 6 sqmm; 4 core conforming to IS:7098 part-I, making cable connections by providing suitable aluminium lugs with proper crimping and steel glands and laid in trenches / ducts / floors / roofs or through pipes etc complete all as specified and directed . 100 RM
14 3.04 Supply, laying, testing and commissioning LT Cable XLPE insulated, galvanised steel strip armoured,1100 volts grade, multistranded copper conductor cable of cross sectional area 2.5 sqmm; 2 core conforming to IS:7098 part-I, making cable connections by providing suitable aluminium lugs with proper crimping and steel glands and laid in trenches / ducts / floors / roofs or through pipes with saddles and fixing screws etc complete all as specified and directed . 120 RM
15 3.05 Excavation in trenches by cutting of road/concrete/bituminous/PCC hard standing getting out and levelling of bottom surface to required level for laying of UG cable/pipe all as specified and as directed. 6 Cum
16 3.06 Supply and fix MCCB 63 amps 4 Pole , 25 KA , 50 Hz 415 Volts to be fixed in existing panel board after making addition alteration and making bus bar extension with necessary of suitable size all as specified and as directed. 2 Each
17 3.07 M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. 2 Each
18 3.08 M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed. 1 Each
19 3.09 S&F vertical type MCCB DB TPN 8 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and directed. 1 Each
20 3.1 S & F MCB TPN 63 amps 415 volts C curve, 50 HZ AC 10 KA including lugs complete all as specified and as directed 2 Each
21 3.11 S & F MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed 1 Each
22 3.12 S & F MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed 2 Each
23 3.13 supply, installation, testing and commissinoning LT panel board suitable for working on 3 phase, 4 wire, 415 volts, AC, 50Hz indoor type, cubicle, floor mounted, free standing, dust and vermin proof, air ventilation factory fabricated made out of 2 mm thick CRCA sheet duly powder coated and shall be CPRI approved and as approved by GE. The Panel shall have front and rear opening,locking arrangement, cable alleys, bus bar chamber and switch gear compartment, hinged door with rubber gasket, bottom cable entry holes for incoming and out going cables, earthing terminals, affix danger notice plate, copper bus bar duly covered with heat shrink sleeves colour coaded duly fixed on DMC/SMC insulators, housed in a separate bus bar chamber and control wiring with copper conductor cables of adequate size and length, incoming and outgoing MCCBs shall have extended bus bar links and mounted on 50x50x5mm size MS angle iron frame duly painted including PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate ) in foundation design subject to approved of GE to sent the site requirement complete all as specified and directed including comprising of following :- 1 Each Job
24 3.131 (a) MCCB 63 Amps, FP, 25 KA, 415 volts, 50Hz- 01 No\n(b) MCB 40 Amps, DP, 10 KA, 415 volts, 50Hz- 02 Nos\n(c) Digital voltmeter, with VSS - 01 set\n(d) Digital Ammeter with CTs & ASS- 01 set\n(e) LED phase indication lamps RYB- 01 set\n(f) Copper bus bar TPN 200 Amps rating - 01 set