| 1 | 1 | Gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe of size 20mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER | | 5 | Each |
|---|
| 2 | 2 | Gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe of size 25mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER | | 5 | Each |
|---|
| 3 | 3 | Gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe of size 40mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER | | 5 | Each |
|---|
| 4 | 4 | Gun-metal, globe or gate valves, ISI marked, with iron wheel head, screwed both ends for iron pipe of size 50mm, fixed in repairs, complete all as specified and as directed by Engr-in-Charge\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER | | 10 | Each |
|---|
| 5 | 5 | Supply and fixing and testing CI sluice valves, 150 mm dia, both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.0) and confirming to IS 780, including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER\n | | 3 | Each |
|---|
| 6 | 6 | Supply and fixing and testing CI sluice valves, 100 mm dia, both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.0) and confirming to IS 780, including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER\n | | 2 | Each |
|---|
| 7 | 7 | Supply and fixing and testing CI sluice valves, 80 mm dia, both ends flanged and drill in with brass spindle and brass check nuts, hand wheel made out of CI complete suitable for tested hydrostatic pressure 15 Kg/Sqcm. (PN 1.0) and confirming to IS 780, including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER\n | | 2 | Each |
|---|
| 8 | 8 | Cast iron non return valve, 150mm dia, heavy duty ISI marked with jointing material flanged joint rubber gasket 6 mm thick nuts, MS nuts, bolts, washers including taking out of existing unserviceable valve complete all as specified and directed by Engineer-in-Charge.\nMAKE: KIRLOSKAR / TATA / ZOLOTO / L&T(AUDCO) / LEADER | | 2 | Each |
|---|
| 9 | 9 | Fittings for spigot and socket pipes upto 150 mm bore such as bends (any type, radius and angle), tapers any type, (Straight, bend, increasing, decreasing, double sockets, etc), Tee pieces single branch, 'Y' junction, double branch, cross (all socket or socket and spigot), collars, caps and plugs, complete all as specified and directed by Engineer-in-Charge. (taking down of old fittings is included in the item for taking down CI pipe)\nMAKE: TATA / SKF / JINDAL SAW / BHARAT STEEL TUBE / NECO (JAYASWAL) / JINDAL / SRIF / UNCO / INDUS / KESORAM / ELECTRO STEEL / KAPILANSH | | 300 | Kilogram |
|---|
| 10 | 10 | Fittings for flanged pipes upto 150 mm bore such as bends (any type radius and angle), Tapers of any type (Straight, bend, increasing, decreasing etc), Tee pieces (single or double branch), any type and angle/radius and straight connecting pieces but all end flanged complete all as specified and as directed by Engineer-in-Charge. (taking down of old fittings is included in the item for taking down CI pipe)\nMAKE: TATA / SKF / JINDAL SAW / BHARAT STEEL TUBE / NECO (JAYASWAL) / JINDAL / SRIF / UNCO / INDUS / KESORAM / ELECTRO STEEL / KAPILANSH | | 250 | Kilogram |
|---|
| 11 | 11 | Cleaning of valve pit chambers, removing algae, silt, sludge accumulated at bottom of valve pit chambers up to the entire satisfaction of Engr-in-charge. | | 10 | Each job |
|---|
| 12 | 12 | Material and labour for chart/ poster/ diagram / name plate etc made out of perpex sheet 2 mm thick, cut to size and shape with colour background and diagram and letters including fixing arrangement with screws / adhesives as required complete all as specified and directed by Engineer in charge.\nNote: The content and size of chart/ poster /diagram / name plate etc shall be as per standard engineering practice given by the Engr in charge during execution of work. | | 34 | Square Metre |
|---|
| 13 | 13 | Repairs to squrial cage vertical motor of capacity 25 HP, 3 phase, 415 volts involving the following operations :\n(a) Opening of the defective motor in MES yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantam of defects and repairs involved.\n(b) Transporting the defective motor to contractors workshop for repairs as decided by the Engineer in Charge and carrying out the needful repairs including replacement of defective unserviceable parts.\n(c) Assembling the motor after repair.\n(d) Spray painting the repaired motor externally with two coats of synthetic enamelled paint of shade as directed by the Engineer in Charge.\n(e) Rewinding of stator motor varnishing & greasing / oiling as required.\n(f) Transporting the repaired motor to MES yard/ workshop and carrying out necessary test in presence of Engineer in Charge to establish the functionability of the repaired motor up to the entire satisfaction of the Engineer in Charge. | | 1 | Each Job |
|---|
| 14 | 14 | M& L for removing bore well column pipes upto 100 mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY of capacity 33HP, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling pump and motor assembly with coloum pipe into the bore well all as specified and as directed.\nNote: Column Pipes will be measured and paid for separatly under relevant Item as \"Supply only\" agnaist unserviceable coloum pipe | | 2 | Each Job |
|---|
| 15 | 15 | M& L for removing bore well column pipes upto 100 mm dia with submersible flat cable of any type and dismantling and taking up/down SUBMERSIBLE PUMP & Motor ASSEMBLY of capacity 10 to 15HP, shifting to workshop and removing unserviceable spares, replacing with new spares such impeller, bushes distance bush, seal etc of same specifications / type / model. removing burnt copper winding from motor and rewinding with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back and testing for proper function including necessary machining works as required , bringing back and reinstalling pump and motor assembly with coloum pipe into the bore well all as specified and as directed.\nNote: Column Pipes will be measured and paid for separatly under relevant Item as \"Supply only\" agnaist unserviceable coloum pipe | | 2 | Each Job |
|---|
| 16 | 16 | Supply only MS column pipe 100 mm dia medium grade (heavy duty) flanged type incl necessary fixing MS nut, bolt, washer & gaskets' etc incl groove for cable entry system of 3 mitre in length complete all as directed. \nMake : Jindal/TATA//BHARAT STEEL TUBE (BST) / GST | | 54 | Each Length |
|---|
| 17 | 17 | Servicing of Hemisphere fountain including cleaning of fountain nozzles, adjustment of fountain nozzles for a precision effect, cleaning of pump suction wire mesh, testing of water proof luminaries, cleaning of toughened glass and heat resistant polyester/polycarbonate filter, tightening all electrical connections of control panel etc and testing of complete fountain installed at Officer Mess Gate complete all as directed. \n(i) Any parts required to be replaced during servicing Fountain shall be measured and paid for separately under appropriate item as \"Supply only\" of this schedule. However labour element involved in replacement is deemed to be included in quoted rates against this item.\n(ii) Any minor repairs involved in servicing to make the Fountain functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department.\n(iii) The item will be operated once in every month during the entire period of the contract and shall be measured seprately number of times the job is carried out. | | 6 | Each Job |
|---|
| 18 | 18 | All as per ser item No. 17.00 here in before but for Multiple jet fountain installed near Technical area gate complete all as specified and as directed by Engineer-in-Charge. | | 1 | Each job |
|---|
| 19 | 19 | Supply only Ball Fountains Nozzles Brass for Hemispherical Fountain.\nMAKE: Approved make/brand as approved by the Engineer-in-Charge and GE . | | 18 | Each |
|---|
| 20 | 20 | Supply only Contactor for Pump MNX-25.\nMAKE: Cat Part No CS94110 of L&T or equivalent approved make in Seimens/Havells. | | 2 | Each job |
|---|
| 21 | 21 | Supply only Timer and Relay.\nMAKE: Cat Part No SS9414500E0 of L&T or equivalent approved make in Seimens/Havells.. | | 2 | Each |
|---|
| 22 | 22 | Supply only 1.5 Watt LED Mirchi Bulb\nMAKE: Cat part No SSK-G4-M15A12C of SYSKA or equal approved in Havells/Bajaj/ Phillips. | | 15 | Each |
|---|
| 23 | 23 | Supply and fixing in repairs LED fountain light fittings complete all as specified and directed by Engr-in-Charge. \nNote :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE\n(ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.\nMAKE: Cat part No SSK-3633-8W of SYSKA or equal approved in Bajaj/Phillips.\n | | 8 | Each |
|---|
| 24 | 24 | Supply, laying and testing PVC insulated and sheathed flat 10 sqmm 4 core copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter as directed including taking out old unserviceable cable complete all as specifed and as directed \nMake : Havells (WHPNDSKB3010) or equivalant | | 37 | RM |
|---|
| 25 | 25 | Supply, laying and testing PVC insulated and sheathed flat 16 sqmm 4 core copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter as directed including taking out old unserviceable cable complete all as specifed and as directed Make : Havells (WHPNDSKB3016) or equivalent | | 30 | RM |
|---|
| 26 | 26 | Cleaning the overhead reservoir cap 50000 gallons to 1.0 lakh gallons (twin or single chamber) by draining the complete water and brushing the surface with iron brush and removing the complete mud/ silt and and washing the complete inner surface of the tank to the entire satisfaction of Engineer in Charge and writing the date of cleaning on surface of tank with white synthetic enamelled paint on black background all as directed.\nNote: T&P, material, labour involved in cleaning shall be arranged by the contractor without any extra cost to the department. | | 3 | Each Job |
|---|
| 27 | 27 | Cleaning the semi underground reservoir cap 50000 lakh gallons (at Kaluchak) by draining the complete water and brushing the surface with iron brush and removing the complete mud/ silt and and washing the complete inner surface of the tank to the entire satisfaction of Engineer in Charge and writing the date of cleaning on surface of tank with white synthetic enamelled paint on black background including covered the opening hole of tank with chicked wire mesh with wooden frame, hinges and locking arrangement complete all as directed by Engr-in-Charge.\nNote: T&P, material, labour involved in cleaning shall be arranged by the contractor without any extra cost to the department. | | 3 | Each Job |
|---|
| 28 | 28 | Cleaning the static tank reservoir cap upto 100000 ltrs at various area by draining the complete water and brushing the surface with iron brush and removing the complete mud/ silt and and washing the complete inner surface of the tank to the entire satisfaction of Engineer in Charge and writing the date of cleaning on surface of tank with white synthetic enamelled paint on black background including covered the opening hole of tank with chicked wire mesh with wooden frame, hinges and locking arrangement complete all as directed by Engr-in-Charge.\nNote: T&P, material, labour involved in cleaning shall be arranged by the contractor without any extra cost to the department. | | 9 | Each Job |
|---|
| 29 | 29 | Cutting wild grass, bushes, creapers, unwanted vegitation from inside / surrounding of installations including cutting creapers from barbed / cattle fencing of the installations as and when required and as directed and removing of unwanted material from installation compound and depositing where directed.\nNote: (a) The item shall be operated maximum four times in entire period of contract in the same installations. (Area will measured separately each time).\n(b) Measurement of cleaning fencing will be measured based on the height between top line and bottom line of barbed wire/ chain link / cattle fencing multiplying by the length involved. | | 4000 | Sqm |
|---|
| 30 | 30 | Supply and fixing LED aviation light of 40 watts including necessary connection with two run of 1.50 sqmm single core unarmoured copper cable from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. \nNote :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE\n(ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.\nMake: Bajaj Cat Part No BGAV302LED or equavalent make of Crompton/Philips/C&S | | 3 | Each job |
|---|
| 31 | 31 | Servicing / maintenance including repairs but excluding spares as required for following components of complete Altoc Dosing system installed at (a) pump house no 08 = 01 tube well x 02 job / month , (b) pump house no 11 = 01 tube well x 02 job / month , (c) pump house no 03 = 01 tube well x 02 job / month, (d) 256 SU Kaluchak pump house = 01 tube well x 02 job / month, including following operations:\n(a) Dismantling of Altoc Dosing System complete part by part in MES yard/ workshop, cleaning of all the stationary and rotary parts and display the parts at site for inspection of Engr-in-Charge to ascertain the serviceability / unserviceability of plant and to ascertain the quantam of defects and repairs involved.\n(b) Transporting the defective parts to authorised dealer for repairs as decided by the Engnr-in-Charge and carrying out the needful repairs including replacement of defective unserviceable parts.\n(c) Assembling the Altoc Dosing System after repair/service and carrying out necessary test in presence of Engnr-in-Charge to establish functionability of the repaired plant upto the entire satisfaction of Engnr-in-Charge.\n | | 48 | Each job |
|---|
| 32 | 31.01 | Note for ser item No 31.00\n(i) Maintenance / servicing of each Altoc Dosing System shall be measured and paid maximum twice in every month. However, in case of unserviceability of the same, the contractor shall be required to carry out the job for its maintenance any number of times as required and directed at site as a case of emergency breakdown.\n(ii) Any parts required to be replaced during repair / servicing of Altoc Dosing System shall be measured and paid for separately under relevant item of this BOQ\n(iii) Any minor parts required to make plant serviceable even if notified by the Engr-in-Charge shall be supplied by the firm without any extra cost to the department.\n | | | |
|---|
| 33 | 32 | Supply only the following (PROVISIONAL) Items to incorproate against item No 31.00 here in before:\n | | | |
|---|
| 34 | 32.01 | a) Rotor assembely with bearing brackets and tolerance rings. Make- Declibac. Cat No- PMBRPL2 or equivalent as E-in-C approved list of make. | | 3 | Each |
|---|
| 35 | 32.02 | b) Coil 250 Volt, 50 Hz. Make- Declibac. Cat No- MP6J222. | | 3 | Each |
|---|
| 36 | 32.03 | c) 07 pump head ( Ferrules 1/4\" & Duckbill included). Make- Declibac. Cat No- UCPH7FD or equivalent as E-in-C approved list of make. | | 3 | Each |
|---|
| 37 | 32.04 | d) 0.7 pump tube ( One pack of 5). Make- Declibac. Cat No- MCCP207. | | 3 | Each |
|---|
| 38 | 32.05 | e) Injection check valve ( One pack of 5). Make- Declibac. Cat No- MCINJ38 or equivalent as E-in-C approved list of make. | | 3 | Pack |
|---|
| 39 | 32.06 | f) Weighted suction line strainer 3/8 \". Make- Declibac. Cat No-ST138 or equivalent as E-in-C approved list of make. | | 3 | Each |
|---|
| 40 | 32.07 | g) 3/8 \" white suction / discharge tubing. Make- Declibac. Cat No- MALT002 or equivalent as E-in-C approved list of make. | | 18 | Running Metre |
|---|
| 41 | 33 | Rewinding of motor of Induction motor up to 1 HP capacity insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed | | 3 | Each |
|---|
| 42 | 34 | Taking down unserviceable dozing system and S&F Chemical Dosing system suitable to injet solution upto 100LPH comprising dosing pump coupled with three phase eletric motor of capacity 0.5 HP, 1440 RPM assembly with agtator in one motor, agitator with SS sweep blade duly FRP coated,FRP tank 150 ltrs capacity,complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete.\nMake: SATHYA SAI AQUA PURA SERVICES or Equivalent make as approved by E-IN-C. | | 2 | Each |
|---|
| 43 | 35 | SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. | | | |
|---|
| 44 | 36 | Note: (1) The repair has to carried out as and when required basis and accordingly site will be available in piecemeal wise and as directed by Enginer-in-Charge in the Air Force station area | | | |
|---|