| 1 | 1 | Dismantling floor hearth or wall tiling including cement mortar bedding removing serviceable tiles to store & rubbish off the premises complete all as specified. | | 70 | Square Metre |
|---|
| 2 | 2 | Taking down chowkats or frames with shutters (without taking off shutters from frames) n exc 1.50 sq. m each and making good the cill, jambs etc using cement mortar 1:6 all as specified and directed | | 6 | Each |
|---|
| 3 | 3 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5.0mm plain colour PVC sheet reinforced with mild steel square tube, and fixing in opening as per specifications and drawing, complete all as specified and as directed. | | 14 | Running Metre |
|---|
| 4 | 4 | S&F Factory Made Solid Panel PVC Door Shutter 30 mm thick (style) consisting of frame made out of Mild Steel Tubes for Top & Bottom Rails having Mild Steel Frame shall be covered with heat moulded plain colour PVC ‘C’ Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and plain colour PVC Sheets for Top Rail, Lock Rail & Bottom Rail on either side and as gap insert for Top Rail & Bottom Rail; Panelling of plain colour PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable PVC Sheet Beading and joined together with Solvent Cement and fixing in the Frame at Site as per Specifications and Drawing, complete all as specified and as directed. | | 5 | Square Metre |
|---|
| 5 | 5 | S&F stainless steel wire cloth, 0.36mm nominal dia or wire and average width or aperature 1.40mm, fixed with stainless steel wire staples complete. | | 2 | Square Metre |
|---|
| 6 | 6 | S&F for powder coated aluminium frame work for doors, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc.complete all as specified (minimum thickness of powder coating 50 micron). | | 15 | Kilogram |
|---|
| 7 | 7 | S&F powder coated aluminium window and ventilator shutters, sliding/fixed type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleat, glazing with clips rubber packing, aluminium snap beading, rollers for sliding and fittings such as handle, clip lock for sliding, screws etc complete all as specified (minimum thickness of powder coating 50 micron). | | 4 | Square Metre |
|---|
| 8 | 8 | M&L for non skid ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc. set & jointed in neat cement slurry & pointed in white or coloured cement to match all as specified | | 15 | Square Metre |
|---|
| 9 | 9 | M&L for glazed ceramic coloured tiles 450x 300x 7 mm thick on vertical surfaces such as skirting, dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over and including CM 1:6, 10mm thick backing coat complete all as specified and directed. | | 55 | Square Metre |
|---|
| 10 | 10 | M&L for Screed bed or bedding layer or mortar in CM (1:6), 15 mm thick for laying in floor finishes all as specified and directed . | | 15 | Square Metre |
|---|
| 11 | 11 | Supply and fix sheet glasses, plain 4.80 mm thick glazing all with aluminium beading, glazing pin etc exceeding 0.5 Sqm in each pane | | 2 | Square Metre |
|---|
| 12 | 12 | M & L complete removal of existing treatment of internal wall surfaces and applying one coat of chalk whiting, preparatory to distempering and applying two coats of distemper oil emulsion white or tinted complete all as specified and directed | | 80 | Square Metre |
|---|
| 13 | 13 | S&F in repair white glazed vitreous china WHB flat back size 550x400 mm including CI bracket etc incl waste coupling and PVC waste pipe 40mm bore 90cm long with coupling spring type complete all as specified | | 2 | Each |
|---|
| 14 | 14 | S& F in repairs pillar tap 15mm bore fancy type, cast copper alloy with capstan heads, chromium plated, screwed down | | 2 | Each |
|---|
| 15 | 15 | S&F 15mm bore CP brass angle cock with wall flange of Make : Jaguar, Cat No OPL-15053 or equivalent of make Cera/Parryware complete all as directed | | 5 | Each |
|---|
| 16 | 16 | S&F in repair vitreous china white wash down water closet pan (pedestal pattern) with trap and fixing bolts (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc.including PVC seat cover complete all as specified and as directed. | | 3 | Each |
|---|
| 17 | 17 | S&F PVC Low Level Flushing Cistern 10 Litre capacity, White, valveless, symphonic action type, with Inlet, Ball Valve, Float and Handle, fixing brackets and connections to pipes complete all as specified and as directed. | | 3 | Each |
|---|
| 18 | 18 | S&F vitreous china urinal, coloured, half stall type including all fitting all as specified. | | 5 | Each |
|---|
| 19 | 19 | S&F Mirror 600x450mm, Beveled Edge, Selected quality Glass, mounted on 6.0mm thick AC Building Board or Commercial Plywood and fixed to Wooden Plugs with Chromium plated Brass Screws and Cup Washers and fixed, complete all as specified and as directed. | | 3 | Each |
|---|
| 20 | 20 | S&F Brass Chromium Plated Tubular Towel Rail, 20mm dia, D type, 60 Cm long between Flanges and fixed, complete all as specified and as directed. | | 3 | Each |
|---|
| 21 | 21 | S&F Toilet Paper Holder Brass, Chromium plated with Rod and fixing to Walls with Chromium plated Brass Screws and fixed, complete all as specified and as directed. | | 3 | Each |
|---|
| 22 | 22 | S & F in repair vitreous china soap dish, white approximate size 160x160x90mm embedded in the wall as specified and as directed. | | 2 | Each |
|---|
| 23 | 23 | S & F PVC connection 15mm bore 45cm long with brass coupling complete. | | 5 | Each |
|---|
| 24 | 24 | S&F in repairs High density poly-ethylene pipes (HDPE) 40mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. | | 4 | Running Metre |
|---|
| 25 | 25 | S&F in repair brass chromium plated bottle trap for wash basins with inlet or outlet screwed for pipe for connection including necessary packing, union and cap (32 mm bore) complete all as specified | | 2 | Each |
|---|
| 26 | 26 | S&F CP health faucet including flexible tube of size 15mm and wall hook complete of make : Jaguar, Cat No. ALD-IVY-583 or equivalent of make Cera/Parryware | | 3 | Each |
|---|
| 27 | 27 | S & F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified | | 6 | Each |
|---|
| 28 | 28 | S&F 300mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections of cast aluminium alloy all as specified | | 3 | Each |
|---|
| 29 | 29 | S&F 100mm mild steel butt hinges, medium weight, cold rold, all as specified | | 9 | Each |
|---|
| 30 | 30 | S&F 150mm long Aluminium anodised handle, cast type all as specified | | 6 | Each |
|---|
| 31 | 31 | S&F PVC (SWR) Floor/ Nahani Trap, Plain, Diameter of Outlet 75mm, with Grating and Jointing to Waste Pipe with Solvent Cement and fixed, complete all as specified and as directed. | | 4 | Each |
|---|
| 32 | 32 | Material and labour for point wiring with 1. 5 Sqmm PVC insulated (FRLS) sheathed multistranded single core copper conductor cable in and including stove enamelled steel concealed conduit of suitable size and including 2mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylam top cover including 1.5 Sqmm PVC insulated (FR) multistranded copper conductor earth continuity wire for one light/fan point controlled by one 5A switch including cutting chasing surface to conceal the conduit and making good the disturbed surface to match with existing surface all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | | 96 | Point |
|---|
| 33 | 33 | Material and labour for point wiring with 1. 5 Sqmm PVC insulated (FRLS) sheathed multistranded single core copper conductor cable in and including rigid non metallic PVC concealed conduit of suitable size and including 2mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylam top cover including 1.5 Sqmm PVC insulated (FR) multistranded copper conductor earth continuity wire for one light/fan point controlled by one 5A switch including cutting chasing surface to conceal the conduit and making good the disturbed surface to match with existing surface all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | | 142 | Point |
|---|
| 34 | 34 | All as per item No 33 above but for one light point controlled by two Nos two way switches, 5 Amps. | | 3 | Point |
|---|
| 35 | 35 | All as per item No 33 above but for one 5 pin 5/6 Amp socket outlet point on independent board | | 50 | Point |
|---|
| 36 | 36 | All as per item No 33 but for one 5 pin 5/6 amps socket outlet point on same board | | 56 | Point |
|---|
| 37 | 37 | All as per item No 33 above but with 2.5sqmm PVC insulated unsheathed stranded copper conductor with 2.5 sqmm PVC (FR) insulated stranded copper wire for continous earthing for one 6 pin 16 amps socket outlet point on independent board | | 15 | Point |
|---|
| 38 | 38 | Material and labour for point wiring with 2. 5 Sqmm PVC insulated (FR) sheathed multistranded single core copper conductor cable in and including rigid PVC concealed conduit of suitable size and including 2mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylam top cover including 2.5 Sqmm PVC insulated (FR) multistranded copper conductor earth continuity wire for one6 pin 16 Amps socket outlet point controlled by one switch including cutting chasing surface to conceal the conduit and making good the disturbed surface to match with existing surface all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | | 3 | Point |
|---|
| 39 | 39 | Material and labour for point wiring with 1. 5 Sqmm PVC insulated (FRLS) sheathed multistranded single core copper conductor cable in PVC casing and caping of suitable size and including 2mm thick MS sheet pressed terminal box (recessed) with 3mm thick laminated hylam top cover including 1.5 Sqmm PVC insulated (FR) multistranded copper conductor earth continuity wire for one light/fan point controlled by one 5 Amp switch on independent board all as specified and as directed by the Engineer-in-Charge. Note : Red/yellow/blue coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. | | 50 | Point |
|---|
| 40 | 40 | All as per item No 39 above, but one 5 pin 5/6 Amps switch socket outlet on independent board | | 30 | Point |
|---|
| 41 | 41 | All as per item No 39 above, but one 5 pin 5/6 Amps switch socket outlet on same board | | 22 | Point |
|---|
| 42 | 42 | All as per item No 39 above but with 2.5sqmm PVC insulated (FRLS) sheathed multistranded single core copper conductor cable for wiring and earthing for one 6 pin 15 amps socket outlet point on independent board | | 5 | Point |
|---|
| 43 | 43 | Supply and fix ceiling rose surface bakelite 65 x 50mm 3 terminals all as specified and as directed by the Engineer-in-Charge | | 205 | Each |
|---|
| 44 | 44 | S & F switch piano flush type 5 Amps SP one way all as specified | | 257 | Each |
|---|
| 45 | 45 | S & F switch piano flush type 5 Amps SP two way all as specified | | 12 | Each |
|---|
| 46 | 46 | S & F switch piano flush type 15 Amps SP one way all as specified | | 20 | Each |
|---|
| 47 | 47 | S & F flame proof weather proof switch rotary type with termination box in LM 6, single pole ON-OFF as per Sudhir Cat Part No.RI/OA/1010-2A or equivalent of other makes complete all as specified | | 96 | Each |
|---|
| 48 | 48 | Supply and fix switch socket combination 6 pin, 16 Amp flush type universal all as specified and as directed by the Engineer-in-Charge | | 23 | Each |
|---|
| 49 | 49 | Supply and fix switch socket combination 5pin, 5 Amp flush type universal all as specified and as directed by the Engineer-in-Charge | | 158 | Each |
|---|
| 50 | 50 | S & F stepped type electronic fan regulator flush type, 230 V all as specified and as directed | | 21 | Each |
|---|
| 51 | 51 | S & F sheet metal enclosure with socket plug top and MCB's single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified | | 4 | Each |
|---|
| 52 | 52 | S & F single pole sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 Volt complete all as specified | | 4 | Each |
|---|
| 53 | 53 | S & F four pole sheet metal enclosure with a two pin and earth plug and socket complete with one four pole MCB 32 Amps, 240 Volt complete all as specified | | 2 | Each |
|---|
| 54 | 54 | S & F four pole sheet metal enclosure with a two pin and earth plug and socket complete with one four pole MCB 63 Amps, 240 Volt complete all as specified | | 2 | Each |
|---|
| 55 | 55 | S & F single pole and neutral sheet metal enclosure for DB 4 ways, double door, 240 V, with 200 Amps rated bus bar complete all as specified | | 11 | Each |
|---|
| 56 | 56 | S & F tripple pole and neutral sheet metal enclosure for DB 6 ways, double door, 240 V, with 200 Amps rated bus bar complete all as specified | | 4 | Each |
|---|
| 57 | 57 | S & F single pole and neutral sheet metal enclosure for MCB DB 8 ways, double door, 240 V, with 200 Amps bus bar complete all as specified | | 3 | Each |
|---|
| 58 | 58 | M&L for submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 4 Sqmm cable as earth continuity wire in and including PVC rigid conduit concealed in wall/floor including cutting chases and making good -the disturbed surface to match with exisitng surface all as specified. Note : (i) Three runs of 4 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 120 | Running Metre |
|---|
| 59 | 59 | M&L for submain wiring with 4 runs of 10 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 10 Sqmm cable as earth continuity wire in and including PVC rigid conduit concealed in wall/floor including cutting chases and making good -the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 10 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 60 | Running Metre |
|---|
| 60 | 60 | M&L for submain wiring with 4 runs of 16 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 16 Sqmm cable as earth continuity wire in and including PVC rigid conduit concealed in wall/floor including cutting chases and making good -the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 16 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 100 | Running Metre |
|---|
| 61 | 61 | M&L for submain wiring with 4 runs of 6 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 6 Sqmm cable as earth continuity wire in and including PVC rigid conduit concealed in wall/floor including cutting chases and making good -the disturbed surface to match with exisitng surface all as specified. Note : (i) Five runs of 6 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 15 | Running Metre |
|---|
| 62 | 62 | M&L for submain wiring with 2 runs of 4 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 4 Sqmm cable as earth continuity wire in and including PVC rigid conduit concealed in wall/floor including cutting chases and making good -the disturbed surface to match with exisitng surface all as specified. Note : (i) Three runs of 4 Sqmm PVC cable and one run of PVC conduit will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 20 | Running Metre |
|---|
| 63 | 63 | M&L for submain wiring with 2 runs of 6 Sqmm PVC insulated unsheathered multi standrard copper conductor cable and one run of 6 Sqmm cable as earth continuity wire in PVC casing and caping all as specified. Note : (i) Three runs of 6Sqmm PVC cable and one run of PVC casing and caping will be measured as one unit length.(ii) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads. | | 150 | Running Metre |
|---|
| 64 | 64 | S & F 20W tube light fitting of ENDURA LINEAR NEO wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver of make Havells, Cat Part No. LHEWEBP61N1W020 or equivalent in other makes as specified | | 36 | Each |
|---|
| 65 | 65 | Fixing only LED tube light/panel light with all accessories, any type, all as specified and directed. | | 38 | Each |
|---|
| 66 | 66 | S&F LED mirror light 1x7Watt wall/surface mounted luminaire with engineering plastic housing, wired with all accessories complete including provision of flexible copper wire from ceiling rose to light fitting terminal of Make : Crompton, Cat No LCL-07-CDL complete all as specified and directed | | 2 | Each |
|---|
| 67 | 67 | S & F LED tube light fitting 1x20W flame proof type CMRI certified with IP 65 protection complete with all accessories, pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed | | 39 | Each |
|---|
| 68 | 68 | S & F LED tube light fitting 2x20W flame proof type CMRI certified with IP 65 protection complete with all accessories, pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed | | 47 | Each |
|---|
| 69 | 69 | S & F LED down lighter' 2'x2', 35 Watt with all accessories and connection to the electric circuit complete all as specified and directed | | 10 | Each |
|---|
| 70 | 70 | Taking down fan, sealing cable end, dismantling blades and removing ceiling fan and blades to store, painting of ceiling fans complete in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and hanging in original position and connecting up including provision of cable from ceiling rose or connector to fan all as specified and directed | | 1 | Each |
|---|
| 71 | 71 | S & F in repair MCCB 63 Amps 4 pole breaking capacity 25 KA at 240 V, with enclosures complete all as specified and directed of make : Havells, Cat No IHLGHF0063 or equivalent in other makes as specified | | 4 | Each |
|---|
| 72 | 72 | S & F in repair MCCB 160 Amps 4 pole breaking capacity 25 KA at 240 V, with enclosures complete all as specified and directed of make : Havells, Cat No IHLGHF0160 or equivalent in other makes as specified | | 2 | Each |
|---|
| 73 | 73 | S & F MCB TP 63 Amps, 415 V complete all as specified and directed of make : L&T, cat part No BF 306300C or equivalent in other makes as specified | | 2 | Each |
|---|
| 74 | 74 | S & F MCB TPN 63 Amps, 415 V complete all as specified and directed of make : L&T, cat part No BF 406300C or equivalent in other makes as specified | | 1 | Each |
|---|
| 75 | 75 | S & F MCB TP 32 Amps, 415 V complete all as specified | | 2 | Each |
|---|
| 76 | 76 | S & F MCB SP 5 to 32 Amps, 240 V complete all as specified and directed of make : L&T, cat part No BB20320Cor equivalent in other makes as specified | | 10 | Each |
|---|
| 77 | 77 | S & F MCB SP 63 Amps, 240 V complete all as specified and directed of make : L&T, cat part No BF 306300 or equivalent in other makes as specified | | 5 | Each |
|---|
| 78 | 78 | S & F MCB SPN 32 Amps, 240 V complete with all incoming/ outgoing connections with proper size lugs of Make Havells, Cat No. DHMCCSNF006-32 all as specified and directed | | 58 | Each |
|---|
| 79 | 79 | S & F MCB SP 6 to 32 Amps, 240 V complete with all incoming/ outgoing connections with proper size lugs of Make Havells, Cat No. DHMCCSPF006-32 all as specified and directed | | 12 | Each |
|---|
| 80 | 80 | S & F MCB SPN 40 Amps, 240 V complete all as specified and directed | | 3 | Each |
|---|
| 81 | 81 | M & L Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0mm thick burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5mtrs below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including earth work, excavation on any type soil and removal of surplus soil to a distance of 50 mtr, PCC 1:2:4 type B1 for earth pit cover 6 Nos 8mm dia CTD bar earth lead protection GI pipe medium grade 20mm size from earth plate electrode to main switch board all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified and indicated including testing on completion | | 6 | Each Set |
|---|
| 82 | 82 | Supply and lay GI tubing, medium grade with all fittings of size 20mm bore fixed to ceilings and connected accessories complete to support for hanging of LED light fittings including necessary fiting arrangement by cutting, clamping with nuts and bolts etc as required at sitel all as specified and directed | | 220 | Running Metre |
|---|
| 83 | 83 | Exhaust fan with louvers 380 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having minimum 5 star rating and including connecting to point complete all as specified of make Havells, model - Venti air - DSP | | 3 | Each |
|---|
| 84 | 84 | S & F Exhaust fan heavy duty with louvers 300 mm sweep 230 Volts AC 50 Hz, single face, 900 RPM, metallic body of make Havells, model - Turbo Force and including connecting to point including making goods disturbed surfaces using cement plaster complete all as specified | | 10 | Each |
|---|
| 85 | 85 | S&F flame proof exhaust fan of size 305 mm sweep complete with louvers as per Sudhir Cat Part No. EF/140 or equivalent of other makes including connecting to point complete all as specified | | 10 | Each |
|---|
| 86 | 86 | S&F 10 KVA UPS for one hour minimum back up single phase AC 180 Volt DC true online 1 GBT based double conversion UPS system built in isolation transformer inside complete all as specified | | 372 | Each |
|---|
| 87 | 87 | Supplying, fixing, connecting, testing and commissioning of energy efficient five star rated ceiling fan white or brown as approved, 1200mm sweep, 230V, 50Hz complete with motor, down rod, blades, canopies, clamps, rubber reel insulator, locking clips etc including connecting from ceiling rose/connector to fan motor using PVC FRLS flexible 2 core cable of size 1.50 Sqmm all as specified and directed. Make of fan - Havells, Model ES-50 5 Star or equivalent in other makes as specified | | 6 | Each |
|---|
| 88 | 88 | S&F industrial wall mounted socket 5 pin type (3P+N+E) 63 amps capacity with IP 67 protection as per Havells Cat Part No.DHQSB65063 or equivalent of other makes all as specified and directed. | | 6 | Each |
|---|
| 89 | 89 | S&F MCB Isolator, 63 Amps, 4 pole as per Havells Cat Part No. DHMGIFPX063 or equivalent of other makes all as specified and directed. | | 1 | Each |
|---|
| 90 | 90 | S&F in replacement MCCB 3 pole, G frame, 160 Amps, breaking capacity 250 VAC, as per Havells Cat Part No. IHMCGNT0160 or equivalent of other makes all as specified and directed. | | 130 | Each |
|---|
| 91 | 91 | S&F in repair FP vertical load line 8 way DB (with MCCB as incomer) suitable for upto 160 Amp MCCB IP 43 all as specified and directed as per Cat Part No.DCDLVDCBGSSTE08 of Crabtree or equivalent make of L&T/Indiasian | | 2 | Each |
|---|
| 92 | 92 | S&F in repair FP vertical load line 4 way DB (with MCCB as incomer) suitable for upto 160 Amp MCCB IP 43 all as specified and directed as per Cat Part No.DCDLVDCBGSSTE04 of Crabtree or equivalent make of L&T/Indiasian | | 2 | Each |
|---|