Provision Of Dg Backup For Security Perimeter Lighting And Watch Towers At Ina Ezhimala, Ezhimala-Kerala

Military Engineer Services-MES has published Provision Of Dg Backup For Security Perimeter Lighting And Watch Towers At Ina Ezhimala. Submission Date for this Tender is 05-03-2020. Diesel Generators Tenders in Ezhimala Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

23634603
Provision Of Dg Backup For Security Perimeter Lighting And Watch Towers At Ina Ezhimala
Open Tender
Indian
Kerala
Ezhimala
05-03-2020

Tender Details

Provision Of Dg Backup For Security Perimeter Lighting And Watch Towers At Ina Ezhimala

Key Value

Document Fees
INR 1000 /-
EMD
INR 133000.0 /-
Tender Value
INR 72 Lakhs /-

BOQ Items

Name of Work: PROVISION OF DG BACKUP FOR SECURITY PERIMETER LIGHTING AND WATCH TOWERS AT INA EZHIMALA
Sl. No. Item Description Item Code / Make Quantity Units
1 1 LIST OF ITEMS OF WORKS 1
2 1.01 Exacavation in trenches not exceeding 1.50meter in width and not exceeding 1.50meter in depth and getting out in hard/dense soil complete all as specified and as directed. 1.01 170 CUM
3 1.02 Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25cm thickness with soil obtained from excavation complete all as specified and as directed. 1.02 60 CUM
4 1.03 Removal of surplus excavated soil to a distance not exceeding 50meter and depositing at a level not exceeding 1.50meter from starting point complete all as specified and as directed. 1.03 110 CUM
5 1.04 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm, 4 core complete all as specified and as directed. Make : Havells/Polycab/Gloster 1.04 200 RM
6 1.05 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm, 4 core complete all as specified and as directed. Make : Havells/Polycab/Gloster 1.05 700 RM
7 1.06 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 Sqmm, 3.5 core complete all as specified and as directed. Make : Havells/Polycab/Gloster 1.06 400 RM
8 1.07 Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 Sqmm, 3.5 core complete all as specified and as directed. Make : Havells/Polycab/Gloster 1.07 60 RM
9 1.08 Supply and spreading natural river sand or riddled earth for cushioning and covering to under ground electric cable in trenches complete all as specified and as directed. NOTE :- Punned thickness shall be measured and paid. 1.08 65 CUM
10 1.09 Supply and lay PCC unreinforced LT cable cover of size 250 mmX150mmX40mm, class LV type-I flat for cable protection complete all as specified and as directed. 1.09 7400 EACH
11 1.1 Supply and fix GI strip 32X6mm as earth continuity conductor or main earthing lead fixed to wall on epoxy /OMC insulators or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all as specified and as directed. 1.1 10 RM
12 1.11 Material and labour for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick, buried directly in ground (earth pit not less than 2.25meter below normal ground level) with top edge of the plate not less than 1.50meter below normal GL, connected to and including galvanized earth lead strip of size 32mmX6mm upto 7.50meter distance and connected by means of bolts, nuts, checknuts and washers of galvanized iron and including 20mm dia medium grade GI watring pipe, funnel with GI wire mesh, GI pipe 40mm dia medium grade for protection pipe, including excavation, earth work in any type of strata, charcoal, salt and PCC chamber, RCC 1:2:4 type B-1 20 mm thick cover with deformed/twisted steel bars 8mm dia @15cm c/c in both ways complete , testing and connecting up complete all as specified and as directed. 1.11 25 EACH
13 1.12 Supply, installing, testing and commissioning factory assembled silent diesel engine driven engine generating set, fully wired alternator AC to give an output of 40 KVA /32 KW continuous rating at a PF lagging, 415 Volts, AC 3 phase 4 wire 50 Hz + 1 % supply, 1500 RPM directly coupled with diesel engine water cooled mounted on common base frame complete with adequate capacity with fuel line accessories, PCC foundation as per Manufacturer's instructions, vibration damper pads, microprocessor based Generator and Alternator monitoring and control system with RS485 interface, AMF control panel and other accessories etc and comprising of the accessories/equipments as indicated in the specification complete all as specified and as directed. 1.12 4 EACH
14 1.13 Supply, installing, testing and commissioning factory assembled silent diesel engine driven engine generating set, fully wired alternator AC to give an output of 62.5 KVA /50 KW continuous rating at PF lagging, 415 Volts AC 3 phase 4 wire 50 Hz + 1 % supply, 1500 RPM directly coupled with diesel engine water cooled mounted on common base frame complete with adequate capacity with fuel line accessories, PCC foundation work as per Manufacturer's instructions, vibration damper pads, microprocessor based Generator and Alternator monitoring and control system with RS485 interface, AMF control panel,and other accessories etc and comprising of the accessories/equipments as indicated in the specification complete all as specified and as directed. 1.13 1 EACH
15 1.14 Note for Sl item Nos. 1.12 and 1.13 :- (i) Any fittings/fixtures which are necessary for proper functioning of the DG set shall also deemed to be included in the unit rate quoted and shall be provided by the contractor without any extra cost to the Govt. (ii) Necessary foundation for installation of DG set and AMF Panel shall be provided as per Manufacturers recommendations and cost of the same shall deemed to be inclusive in the rate quoted for this item. (iii) All testing equipments including arrangement of electrical load for testing and consumables like oil, diesel etc., are to be arranged by the contractor and testing shall be carried out by the contractor in presence of Engineer-in-Charge, testing officer nominated by the Accepting officer. (iv) Unit rate quoted by the contractor includes first filling of lubricating oil, Coolant, Carrying out "B" check after first 50 Hrs of DG run or as per OEM recommendations during the maintenance period. AMF panel must be out side the canopy, weather proof outdoor type. (v) Unit rate quoted by the contractor includes necessary termination of incoming and outgoing cables / dismantling and reconnecting the existing cables if any as required at site. The decision of Engineer-in-Charge shall be final and no extra payment shall be admissible on this account. (vi) Cable from DG set to AMF, AMF panel to Main panel shall be measured under respective items of BOQ.
16 1.15 Note for Sl item Nos. 1.12 and 1.13 :- (i) Drawings/catalogue for DG Set, AMF panel, LT Panel shall be approved by the GE before ordering on the Manufacturer. The LT panel shall be CPRI approved. (ii) The tenderer shall provide the Operator Manual, spare parts, catalogue, AMF circuit diagram, etc on completion of work.. Unit rate quoted by the contractor includes the same.
17 1.16 M&L for Ring main unit 11KV 630 A,21 KA for 3 sec outdoor type motorized both side extensible, 4way module consisting of 1 No Load break switch and 3Nos Vaccum Circuit Breaker- RMU with enclosure, with internal arc classification compilied to IEC 62271, Nominal voltage 11KV, rated frequency 50 Hz, copper busbars of 630 Amp rating, Rated copper current cable,switch disconnector 630 Amp, Rated current for Transformer T-off 200/630 A,Pressure of SF 6 gas1.4 bar at 20 degree Celcius Short time withstand current; Cable switch disconnector with interface C (400-bolt) bushing; 21 KArms 3 sec,Vacuum circuit breaker with interface C ( 400-bolt) bushing; 21kArms 3 sec Impulse withstand voltage; to earth and between phases; 75 kV, insulation level- power frequency 1 min 28 kV, Temperature class(-) 25 degree Celcius to (+) 40 degree celcius outdoor, Degree of protection SF- 6 tank IP-67,fuse canisters IP-67,front cover- IP 2X, cable cover- IP 3X,enclosure IP-54, metal enclosed switch gear IEC 62271- 200,general purpose switches-IEC 60265-1,disconnectors and earthing switches IEC-62271-102,switch fuse combination IEC-62271-105,circuit breakers IEC-62271-100, LBS module consisting cable switch 12KV 630Amp-01 No,bushing outside cone interface C for connection of external bus bars-01No,mano meter-01no,snap action mech for motor operation-01No,control voltage motor operation 24Volts DC -01No,cable cover standard with interlocking-01No,cable bushings interface C-(400 bolted) 630Amps standard -01No,short circuit and earth fault indicator of make;-Seimens/EMG-01 N0,capacitive voltage indication fixed type VPIS 9-15 KV-01No,Aux switch for load break switch position 2no+2NC-01No,cable support bars,standard for one way unit-01no,VCB module consisting Vacuum circuit vbreaker 12KV 630Amp-01No,stored energy mech for motor operation-01No,control voltage motor operation 24Volt Dc-01No,cable cover standard with inter locking-01No,self powered over current and earth fault p[rotection relay with RS 485port type ADR 241 S/CSDPR-01No,cable bushing interface C (400bolted) 630Amp-01No,Aux switch for vacuum circuit breaker position-02Nos+2Nc-01No,support bars standard for 1 way units-01No.Ring core current transformer type 100/1A,2.5VA,5P10for protection-03Nos.Note;- The cost of foundation and plinth for installation of RMU shall be included in the quoted rates.Design and dimension of concrete structure will be as per the manufacturer's instructions.Make;- ABB India Ltd/Siemens/Schneider. 1.16 2 EACH