}

Tender For Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites Under Kalyan Ssa, Mumbai-Maharashtra

Bharat Sanchar Nigam Limited has published Tender For Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites Under Kalyan Ssa. Submission Date for this Tender is 11-03-2020. Air Conditioner Tenders in Mumbai Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

23632487
Tender For Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs/ Bts Sites Under Kalyan Ssa
Tender
Indian
Maharashtra
Mumbai
11-03-2020

Tender Details

Tender For Call Basis Maintenance Of Wac, Sac Units At Various Te Bldgs / Bts Sites Under Kalyan Ssa , Attending And Rectification Of Existing Window / Split Ac Faults Including Providing Minor Spares If Reqd Such As Connecting Copper Wires , Removing & Cleaning Of Filters , Cleaning Of Units By Blowers , Control Fuse , Ferrules , Lugs I / C Minor Works Etcalongwith Testing & Commissioning In Urban Site Complete As Required . ( Item Will Be Measured On Submission Of Visit Report Duly Signed By Bsnl Authority And Allowed At Once Per Site Per Fault ) ( Note:- For Subsequent Visit To Attend The Window / Split Ac To Provide The Items Hereunder Will Not Be Paid Separately . It Is Assumed That All Items As Below Shall Be Carried Out By Firm In First Visit Only ) , Attending And Rectification Of Existing Window / Split Ac Faults Including Providing Minor Spares If Reqd Such As Connecting Copper Wires , Removing & Cleaning Of Filters , Cleaning Of Units By Blowers , Control Fuse , Ferrules , Lugs I / C Minor Works Etcalongwith Testing & Commissioning In Rural Site Complete As Required . ( Item Will Be Measured On Submission Of Visit Report Duly Signed By Bsnl Authority And Allowed At Once Per Site Per Fault ) ( Note:- For Subsequent Visit To Attend The Window / Split Ac To Provide The Items Hereunder Will Not Be Paid Separately . It Is Assumed That All Items As Below Shall Be Carried Out By Firm In First Visit Only ) , Carrying Out Wet Servicing Of 1 . 5Tr / 2Tr Window / Split Ac Unit I / C Removing , Cleaning All Components And Filters , Dedusting By High Pressure Air Blower , Washing Condenser , Evaporator I / C Chemical Cleaning ( If Required ) , Refixing , Tightening Electrical Connections , Testing Of Ac Unit , Recording All Parameters In Service Report Etc As Reqd . , Carrying Out Leak Testing Of 1 . 5Tr / 2 Tr Split / Wac Ac Units With Nitrogen Gas Including Dismantling Of Machine , Flushing The System , Brazing / Flaring The Leak Points , Vacumising , Purging And Making The System Leak Proof I / C Transportation Of Nitrogen Cylinder , Brazing Kit & Vacuum Pump , Supplying & Charging Of R22 Refrigerant Gas At Site , Reinstallation , Testing & Commissioning Etc As Required . , 1 . 5 Tr , 2 . 0 Tr , Replacement Of Following Capacity Of Existing Old Defective Compressor With New Sealed Compressor I / C Dismantling Of Faulty Compressor , Cutting Refrigerant Piping , Brazing & Making Necessary Addition / Alteration I / C Proper Mounting On Base Plate , Connection Of Suction And Discharge Lines , Leak Test & Charging Refrigerant I / C Testing Etc As Reqd . ( M / S Emerson / Tecumseh / Ss Make ) ( Note- The Firm Shall Submit Test Certificate Or Documentary Proof Towards Purchase Of New / Oem Factory Repaired Compressor . ) The Defective Compressor Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory ) , 1 . 5 Tr , 2 . 0 Tr , Replacement Of Following Material For Repairing & Attending Break Down Complaints Of 1 . 5 / 2 Tr Wac / Sac Units I / C Dismantling , Connection , Fixing & Testing Etc As Required ( Note- The Defective Material Shall Be The Property Of Agency & Firm Should Consider Suitable Price Rebate For The Same While Quoting . The Material Under Replacement Shall Be Similar To Existing Defective Material Or As Per Product Directory . , Starting Capacitor ( Metal Body ) Of Rating 80 / 100 Mfd ( M / S Epcos / Asian / Ss Make ) , Running Capacitor ( Metal Body ) Of Rating 36 Mfd ( M / S Epcos / Asian / Ss Make ) , Repairing Of Control Card Of Indoor Split Ac Unit , Replacement Of Control Card Pcb Suitable For 1 . 5Tr Split Ac Units , Condenser Fan Blade ( Pvc / Frp ) , Box Type Relay For Window Ac Units . ( M / S Arvind / Ranutrol / Ss Make ) , Selector Switch For Window Ac Units , Blower Fan Motor For Idu Of Split Ac Unit ( M / S Aue / Marathonge / Natinoal / Diamond / Ss Make ) , Thermostat ( M / S Danfoss / Indfoss / Arvind / Ss Make , Washable Nylon Air Filter , Replacement Of Condenser Motor Of 1 . 5 / 2 Tr Split / Window Ac Unit From Workshop Complete With Reinstallation , Testing Etc As Required , Replacement Of Rusted Base Plate Of Window Ac 1 . 5 Tr Unit With Ms Sheet Plate I / C Fabrication & Mounting Of All Accessories Etc As Required . , Dismantling & Shifting Of Existing Indoor & Outdoor Unit From One Site & Itc At Another Site & Dismantling Existing / Faulty Unit & Keeping It To The Location As Directed By Engineer-In-Charge Etc . Complete Testing , Connections Complete As Reqd . ( Note: Transportation Charges Shall Be Paid Extra )

Key Value

Document Fees
INR 590 /-
EMD
INR 14641.0 /-
Tender Value
INR 7.32 Lakhs /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail