| 1 | 1 | B/R work | | | |
|---|
| 2 | 2 | M&L for PCC M-10 grade (Nominal Mix) using 40mm graded crushed stone aggregate as in surface channel and drains complete all as specified and directed. | | 6 | CUM |
|---|
| 3 | 3 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and directed. | | 30 | RM |
|---|
| 4 | 4 | M & L for PCC M-15 grade (Nominal mix) using 20mm graded crushed stone aggregate as in coping including necessary formwork complete all as specified and as directed. | | 3 | CUM |
|---|
| 5 | 5 | M & L for RCC M-15 grade (Nominal mix) using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. | | 0.35 | CUM |
|---|
| 6 | 6 | M&L for brick work with subclass ‘B’ bricks, (locally available best quality) old size bricks straight or curved on plan exc 6 m means radius, built in cement mortar (1:6) complete all as specified and directed. | | 35 | CUM |
|---|
| 7 | 7 | Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished surface of concrete complete all as specified and directed | | 10 | SQM |
|---|
| 8 | 8 | M&L for well seasoned 2nd class hard wood in scantling, wrought timber framed and fixed complete all as specified and directed. | | 0.8 | CUM |
|---|
| 9 | 9 | M&L for well seasoned 2nd class hard wood in scantling, clean sawn timber framed work complete all as specified and directed. | | 0.1 | CUM |
|---|
| 10 | 10 | Ditto all as per Sl item No. 9.00 here-in-above but except scantling (NOTE: Seviceable wooden scantling obtained from dismantling under Sl item No 84.00 here-in-after shall be reused under the item) | | 0.05 | CUM |
|---|
| 11 | 11 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each and removing all unserviceable materials from site complete all as specified and directed. | | 7 | EACH |
|---|
| 12 | 12 | Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but not exc. 4 sqm each and removing all unserviceable materials from site complete all as specified and directed. | | 9 | EACH |
|---|
| 13 | 13 | Taking down shutters of any description exc. 1 sqm and not exc. 2 sqm each and removing all unserviceable materials from site complete all as specified and directed. | | 1 | EACH LEAF |
|---|
| 14 | 14 | S&F 2nd class hardwood plain solid straight chowkhats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed. | | 0.72 | CUM |
|---|
| 15 | 15 | S&F for 35mm thick well seasoned 2nd class hardwood glazed and skeleton shutter open rebated and prepared to receive glass etc. (without sash bar) edges of framing plain chamfered or rounded fitted with cut and mitred bead for securing gauge etc size of members of shutter as specified in SSR Part-I section 8 clause 8.24(a) complete all as specified and directed. | | 8.1 | SQM |
|---|
| 16 | 16 | S&F for 30mm thick well seasoned 2nd class hardwood glazed and skeleton shutter open rebated and prepared to receive glass etc. (with sash bar) edges of framing plain chamfered or rounded fitted with cut and mitred bead for securing gauge etc size of members of shutter as specified in SSR Part-I section 8 clause 8.24(b) complete all as specified and directed. | | 16.1 | SQM |
|---|
| 17 | 17 | S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. | | 13.15 | SQM |
|---|
| 18 | 18 | S&F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like and all necessary' labours; articles n exc 200 cu. cm each complete all as specified and directed | | 15 | EACH |
|---|
| 19 | 19 | S&F 50mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. | | 15 | EACH |
|---|
| 20 | 20 | S&F 75mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. | | 24 | EACH |
|---|
| 21 | 21 | S&F 100mm long butt hinges medium weight cold rolled mild steel complete all as specified and directed. | | 30 | EACH |
|---|
| 22 | 22 | S&F 75mm long stainless steel butt hinges complete all as specified and directed. | | 16 | EACH |
|---|
| 23 | 23 | S&F 100mm long stainless steel butt hinges complete all as specified and directed. | | 15 | EACH |
|---|
| 24 | 24 | S&F 100mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. | | 18 | EACH |
|---|
| 25 | 25 | S&F 150mm long aluminium anodised of extruded section barrel tower bolts complete all as specified and directed. | | 20 | EACH |
|---|
| 26 | 26 | S&F 100mm long alumiunium handles cast type anodised complete all as specified and directed. | | 12 | EACH |
|---|
| 27 | 27 | S&F 150mm long alumiunium handles cast type anodised complete all as specified and directed. | | 30 | EACH |
|---|
| 28 | 28 | S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor with 140mm overall length of cover plate complete all as specified and directed. | | 11 | EACH |
|---|
| 29 | 29 | S&F in repairs stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. | | 3 | SQM |
|---|
| 30 | 30 | S&F galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width or aperture 1.18mm complete all as specified and directed. | | 5.62 | SQM |
|---|
| 31 | 31 | S&F in repairs galvanised mild steel wire cloth 0.56mm nominal dia of wire and average width or aperture 1.18mm complete all as specified and directed. | | 1 | SQM |
|---|
| 32 | 32 | S&F structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S.1161-1979 grade St.-240 complete all as specified and as directed. | | 450 | KG |
|---|
| 33 | 33 | S&F Structural steel work in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Grade E-250) quality-A complete all as specified and as directed. | | 220 | KG |
|---|
| 34 | 34 | M&L for TMT bars 10mm dia and over cut to length, bent to shape as required including cranking, bending and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed | | 100 | KG |
|---|
| 35 | 35 | M&L for TMT bars 6mm to 8mm dia, cut to length, bent to shape as required including cranking, bending and binding with mild steel wire(annealed) not less than 0.9mm dia as in reinforcement bar complete all as specified and directed | | 40 | KG |
|---|
| 36 | 36 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed | | 100 | SQM |
|---|
| 37 | 37 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters, drip, straight flashing etc fixed with self tapping screws complete all as specified and directed | | 10 | SQM |
|---|
| 38 | 38 | S&F 0.63mm plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip, wall cladding and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed. | | 20 | SQM |
|---|
| 39 | 39 | S&F exposed GI powder coated snap grid frame work for false ceiling of grid size 600 x600mm comprising of wall/cleat angle of size 22 x22 x0.50mm and main tee of size 25 x30 x0.50mm and cross tee of size 23.5 x26.4 x0.50mm with 2mm dia GI wire as suspender and including 4mm thick Plain E-Board including fixing arrangement from steel truss of any type and applying two coats of oil bound distemper over one coat of chalk whiting complete all as specified and directed. | | 80 | SQM |
|---|
| 40 | 40 | M & L for 4mm thick plywood (no of ply 03), grade BWR, type BB, fixed with nails to timber frame work in walls complete all as specified and directed. | | 40 | SQM |
|---|
| 41 | 41 | M & L for 6mm thick plywood (no of ply 05), grade BWR, type BB, fixed with nails to timber frame work in walls complete all as specified and directed. | | 10 | SQM |
|---|
| 42 | 42 | S&F 18/19mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed | | 20 | SQM |
|---|
| 43 | 43 | S&F 0.90mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed | | 5 | SQM |
|---|
| 44 | 44 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, 30mm width of flaps complete all as specified and directed | | 10 | RM |
|---|
| 45 | 45 | S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed | | 10 | EACH |
|---|
| 46 | 46 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as directed | | 2 | SQM |
|---|
| 47 | 47 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed. | | 62 | SQM |
|---|
| 48 | 48 | M&L 100mm thick PCC M-10 grade (Nominal Mix) using 40mm graded crushed stone aggregate in sub base, finishes even complete all as specified and directed. | | 70 | SQM |
|---|
| 49 | 49 | M&L 25mm thick PCC M-15 grade (Nominal Mix) using 12.5mm graded crushed stone aggregate in floor, finishes even and rough to receive floor tiles complete all as specified and directed. | | 91 | SQM |
|---|
| 50 | 50 | M & L for 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor tiles etc complete all as specified and directed. | | 93 | SQM |
|---|
| 51 | 51 | M & L for 20mm thick screed bed or bedding layer in cement mortar (1:3) for laying chequerred tiles complete all as specified and directed. | | 70 | SQM |
|---|
| 52 | 52 | M&L coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | | 2 | SQM |
|---|
| 53 | 53 | M&L coloured non-skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floor, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. | | 91 | SQM |
|---|
| 54 | 54 | S&F Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in cement mortar (1:4) complete all as specified and directed. | | 60 | SQM |
|---|
| 55 | 55 | S&F Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tile including 10mm thick cement mortar backing in cement mortar (1:4) complete all as specified and directed. | | 2 | SQM |
|---|
| 56 | 56 | M&L for precast chequered cement concrete tiles 30cm x 30cm x 25mm thick conforming to IS 13801-1993, set, jointed in neat cement slurry and pointed with grey cement and pigment as in floors complete all as specified and directed. | | 70 | SQM |
|---|
| 57 | 57 | S&F 20mm thick granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) over and including12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. | | 1 | SQM |
|---|
| 58 | 58 | S&F 20mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15mm thick in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. | | 5 | SQM |
|---|
| 59 | 59 | M&L for 75mm thick PCC M-10 grade (Nominal Mix) using 40mm graded crushed stone aggregate as in plinth protection finishing surfaces even and smooth without using extra cement complete all as specified and directed. | | 40 | SQM |
|---|
| 60 | 60 | M&L rendering 15mm thick on fair faces of brick work in cement mortar 1:4 using water proofing compound @2% by weight of cement as per manufacture instruction and finishing even and smooth without using extra cement all as specified.\n(Note: Plastering shall be carried out using Dimapur Sand. WPC will be measured and paid separately)\n | | 170 | SQM |
|---|
| 61 | 61 | M & L for rendering 10mm thick plaster in cement mortar (1:6) on other than fair faces of brick work or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. (Note: Plastering shall be carried out using Dimapur Sand) | | 140 | SQM |
|---|
| 62 | 62 | Supply only integral water proofing compound. | | 5 | KG |
|---|
| 63 | 63 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of whitewash complete all as specified and directed. | | 170 | SQM |
|---|
| 64 | 64 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified and directed. | | 140 | SQM |
|---|
| 65 | 65 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed. | | 2.5 | SQM |
|---|
| 66 | 66 | S&F sheet glass 3mm thick, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and as directed. | | 5.56 | SQM |
|---|
| 67 | 67 | M&L for preparation of new zinc (or galvanised) surfaces to receive painting by coating with mordant solution including washing and cleaning etc and applying two coats synthetic (red) roof paint over a coat of red oxide primer complete all as specified and directed. | | 20 | SQM |
|---|
| 68 | 68 | M&L for preparing of new wooden surfaces of any description and girth, not otherwise described and treated with a coat of creosote oil complete all as specified and directed. | | 5 | SQM |
|---|
| 69 | 69 | M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer on wooden surfaces complete all as specified and directed. | | 102 | SQM |
|---|
| 70 | 70 | Taking up or down 15mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. | | 40 | RM |
|---|
| 71 | 71 | Taking up or down 20mm dia of steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and directed. | | 30 | RM |
|---|
| 72 | 72 | S&F GI tubing 15mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | | 40 | RM |
|---|
| 73 | 73 | S&F GI tubing 20mm bore, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed. | | 30 | RM |
|---|
| 74 | 74 | S & F in repairs bib taps, ISI marked cast copper alloy, chromium plated fancy type screwed down, screwed for iron pipe or for brass ferule for 15 mm bore dia of pipe complete all as specified and directed. | | 4 | EACH |
|---|
| 75 | 75 | S&F in repairs stop valve of PTMT any colour high pressure screwed for iron pipe and fixed for 15 mm bore dia of pipe complete all as specified and directed. (Minimum weight 90gms) | | 2 | EACH |
|---|
| 76 | 76 | Dismantling water tanks capacity exc. 500 litres and n.exc. 1000 liters and removing to store complete all as specified and directed. | | 2 | EACH |
|---|
| 77 | 77 | S&F rotational moulded polyethylene water storage tank, ISI marked, 1000 litres capacity of multilayered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including all necessary inlet/outlet connections & brass ball valve complete all as specified in SSR Part-I and as directed. | | 2 | EACH |
|---|
| 78 | 78 | S&F ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed 20 mm bore dia of pipe complete all as specified and directed. | | 2 | EACH |
|---|
| 79 | 79 | Dismantling of galvanised plain/ corrugated including Nainital or similar pattern mild steel sheeting of any gauge, thickness roof coverings and removing unserviceable materials from site of work complete all as specified and directed. | | 130 | SQM |
|---|
| 80 | 80 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as directed. | | 6.7 | QTL |
|---|
| 81 | 81 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. | | 80 | SQM |
|---|
| 82 | 82 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed. | | 50 | SQM |
|---|
| 83 | 83 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and pre-cast concrete articles and removing unserviceable materials from site of work complete all as specified and directed. | | 35 | CUM |
|---|
| 84 | 84 | Dismantling timber scantlings 40 sq. cm and over in section, in unframed work and in any position complete all as directed. | | 0.95 | CUM |
|---|
| 85 | 85 | Demolition of cement concrete (unreinforced) in ground floor and pavings not exc 15 cm thick thickness below or above ground level complete all as specified and directed. | | 23 | CUM |
|---|
| 86 | 86 | Demolition of cement concrete (reinforced) of any description and any thickness below or above ground level complete all as specified and directed. | | 0.35 | CUM |
|---|
| 87 | 87 | E/M work | | | |
|---|
| 88 | 88 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, etc., not exceeding 10 Sqm on plan and laying of cables or pipes, not exceeding 1.5m in depth and getting out in hard/dense soil complete all as specified and directed. | | 10 | CUM |
|---|
| 89 | 89 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed. | | 7 | CUM |
|---|
| 90 | 90 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed. | | 3 | CUM |
|---|
| 91 | 91 | Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down complete all as specified and directed.\n(Note: Thickness of sand cushion after punning down will be measured and paid.)\n | | 2.8 | CUM |
|---|
| 92 | 92 | Supply and laying well burnt sub class ‘B’ bricks (designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed. | | 300 | NOS |
|---|
| 93 | 93 | Supply, laying, jointing and connecting, LT UG cable XLPE insulated , PVC bedded , galvanised steel strip or wire armoured, electric power cable ( heavy duty) 1100 volts grade with stranded aluminium conductor of size 4sqmm 2 core ,laid in trenches / on poles / walls / in ducts / passing through pipes etc including jointing materials such as cable glands, lugs etc complete all as specified and as directed. | | 30 | RM |
|---|
| 94 | 94 | S&F Service wire PVC insulated and PVC sheathed stranded Aluminium conductor 6Sqmm 2 Core fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulator complete all as directed. | | 20 | RM |
|---|
| 95 | 95 | Supply, erecting & fixing of steel tubular swaged poles, type 410 SP 31 (Overall length 9.00 m) complete with cast iron base plate, finial taper plug, bolts, nuts screws and washers including cleaning, scrapping, preparaing old painted surface & painting two coats of black bituminous paint internally and externally up to planting depth and remaining external portion with two coats of aluminum paints over a coat of red oxide primer incl painting black and white alternate strips of 30cm each from ground level up to 1.5 meter and writing pole Nos with white paint on black back ground complete all as specified and as directed. | | 4 | EACH |
|---|
| 96 | 96 | M&L for PCC M-7.5 grade (Nominal mix) using 40mm graded crushed stone aggregate as in foundation of pole, protection of UG cable, concrete base, etc complete all as specified and directed. | | 1.4 | CUM |
|---|
| 97 | 97 | M&L for PCC M-10 grade (Nominal mix) using 20mm graded coarse stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed. | | 0.3 | CUM |
|---|
| 98 | 98 | Supply and laying 25mm bore GI tubing light grade as in cable protection pipe including all fittings complete all as specified and directed. | | 6 | RM |
|---|
| 99 | 99 | S&F LED flood light fitting 50W Energy saving, environmental friendly, long life, exclusive innovative dia-cast aluminium flood light with high power LEDs as light source, suitable for highlighting architectural features or Area lighting complete all as specified and directed.(Make: Havells JETA COMPACTO Cat No. JETACOMPACTOFL50WLED757LTG /Philips / CG/ Bajaj) | | 4 | EACH |
|---|
| 100 | 100 | S&F hot press moulded SMC junction box of size (300 x 200 x 105)mm, pole mounted, including 01 Nos MCB SP 6 to 10Amps capacity, aluminium bus bas-04 Nos fixed on ebonite insulator of suitable capacity for 3 phase and neutral and fixed to pole with two numbers mild steel clamp of 25 mm width, 3mm thick MS flat strip and four nos nuts, bolts & washers of 12mm dia 150mm long complete all as specified and directed. (Make: Sintex Cat No. GSJB-3020 or equivalent in Bansal/C&S Electricals) | | 2 | EACH |
|---|
| 101 | 101 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed. | | 4 | EACH |
|---|
| 102 | 102 | M&L for Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. | | 4 | EACH |
|---|
| 103 | 103 | Supply and laying 50mm bore GI tubing light grade as in cable/earth lead protection pipe including all fittings fixed to wall/ceiling or floors complete all as specified and directed. | | 12 | RM |
|---|
| 104 | 104 | S&F 32 x 6mm GI strip for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed. | | 128 | RM |
|---|
| 105 | 105 | M&L for earthing complete with galvanized steel plate electrode 600 X 600 X 6 mm thick buried directely in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI earth strip of size 32mm x 6mmmm as earthing lead by means of galvanized steel bolts,nuts check nuts and washers and other end connected with to Transformer, DG sets, Pannel board etc as directed including funnel, 20 mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50 mm thick pre cast RCC 1:2:4 type B1 with 8mm dia cover slab set in CM (1:4) reinforcement with 8mm dia deformed bars @ 15 cm C/C and suitable handle of 10mm dia MS round bars, including earth work as required complete all as shown in electrical plate No. 5 of MES schedule Part I and testing complete all as specified and as directed.\n(Note: GI Earthing strip upto 7.5m in lenght is deemed to be included in the unit rate. The Strip required beyond 7.5m shall be measured and paid for separately) | | 4 | EACH SET |
|---|
| 106 | 106 | Taking down carefully unserviceable aluminum/ copper point wiring (light/ fan/ socket/ power) complete including fixture & fitting such as switches, sockets, ceiling roses regulators, lamp holder etc. but excluding light fittings & fixture and exhaust fans etc removing and making good disturbed surfaces of wall/ceiling etc complete all as specified and directed. | | 35 | POINT |
|---|
| 107 | 107 | Material and labour for point wiring surface type with two single core 1.5 Sq mm (nominal area) FRLS PVC insulated and unsheathed, multi-stranded, copper conductor cable in and including suitable size PVC casing capping with all fittings and fixing accessories and suitable size PVC box for mounting switches, regulator etc including multi-strand PVC insulated unsheathed stranded copper cable as earth continuity conductor of size 1.5 Sq mm and connecting to light fitting/fans etc complete all as specified and directed for following :- (Colour code to be followed) | | | |
|---|
| 108 | 107.1 | One light/fan point controlled by one, one way switch | | 22 | POINT |
|---|
| 109 | 107.2 | One socket outlet 5 Amps 5 pin on independent board | | 8 | POINT |
|---|
| 110 | 107.3 | One socket outlet 5 Amps 5 pin on same board with other switches | | 3 | POINT |
|---|
| 111 | 107.4 | All as per item No. 107 here in before but with cable size 2.5 Sqmm and earth continuity conductor of 2.5 Sqmm size for one 5 pin 15 Amps socket out let on independent board complete all as specified and directed. | | 2 | POINT |
|---|
| 112 | 108 | S&F modular switch piano, 6 Amps, single pole, one way complete all as specified and directed. | | 33 | EACH |
|---|
| 113 | 109 | S&F modular switch piano, 16 Amps, single pole, one way complete all as specified and directed. | | 2 | EACH |
|---|
| 114 | 110 | S&F modular socket outlet 2/3 Pin 6 Amps combined 2 module complete all as specified and directed. | | 11 | EACH |
|---|
| 115 | 111 | S&F modular socket multipurpose 3 pin 16 Amps and 3 pin 6 Amps combined 2 module complete all as specified and directed. | | 2 | EACH |
|---|
| 116 | 112 | S&F Ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body complete all as specified and directed. | | 22 | EACH |
|---|
| 117 | 113 | S&F modular white cover with frame for fixing of 3 module. | | 10 | EACH |
|---|
| 118 | 114 | S&F modular white cover with frame for fixing of 4 module. | | 1 | EACH |
|---|
| 119 | 115 | S&F modular white cover with frame for fixing of 8 module. | | 3 | EACH |
|---|
| 120 | 116 | S&F blank spacer plate for single module. | | 4 | EACH |
|---|
| 121 | 117 | S&F modular electronic fan regulator rotary stepped type 120W, 240V, single phase, two module and connecting up complete all as specified and directed. | | 4 | EACH |
|---|
| 122 | 118 | Taking down old unserviceable main switch/ DBs/ MCB DBs with MCB including making good the disturbed surface complete as directed. | | 1 | EACH |
|---|
| 123 | 119 | S&F sheet metal enclosure for MCB’s distribution board, 240 Volts, 8 ways single pole and neutral including 200 Amps rated busbar, neutral link, din rail double door verticle for breaking capacity 10 KA complete all as specified and directed.\n(Make: Havells cat part No. DHDPSHODRW 08 or as per list approved makes enclosed hereinafter) | | 1 | EACH |
|---|
| 124 | 120 | S&F MCB single pole and neutral 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. | | 1 | EACH |
|---|
| 125 | 121 | S&F MCB single pole 06 to 32 Amps, ‘C’ series 240 Volts, breaking capacity 10KA complete all as specified and directed. | | 6 | EACH |
|---|
| 126 | 122 | S&F PVC Board (30 x 25 x 5) cm depth medium quality ISI marked complete all as directed. | | 1 | EACH |
|---|
| 127 | 123 | Taking down old unserviceable light fitting of any type and in any situation complete all as directed. | | 18 | EACH |
|---|
| 128 | 124 | S&F universal batten for G13 T8 lamps (LED TUBE),1200mm long complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. \n(Make: Havells Regal Batten Cat No.REGALBATTENT8UPTO1X22WSSBSWH or equivalent in Philips/ Bajaj/ Crompton) | | 10 | EACH |
|---|
| 129 | 125 | S&F ultra bright LED polycarbonate tublight 20W, 1213mm long with very high efficacy suited for installation T8 tublight with G13 lamp holders, complete with all accessories complete all as specified and directed.\n(Make: Photon Ultra LED tublight Havells Cat No.PHOTONULTRA1213T8SSTL20WLED865SPCor equivalent in Philips/Bajaj/CG) | | 10 | EACH |
|---|
| 130 | 126 | M&L for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendent/Angle type including one 10W LED complete all as specified and directed. | | 4 | EACH |
|---|
| 131 | 127 | S&F building security light fitting new generation energy saving & environmental friendly long life versatile pressure die cast aluminium IP-66 high power LED light 20 watt including suitable size of wall bracket and connecting up with twin core twisted flexible copper conductor cable complete all as specified and directed. \n(Make: Havells Endura Pearl Cat No. ENDURAPEARLSL20WLED757SASYTOPC or equivalent in Bajaj/Philips/Crompton) | | 4 | EACH |
|---|
| 132 | 128 | Taking down old unserviceable service cable including batten/suspending wires complete all as directed. | | 60 | RM |
|---|
| 133 | 129 | S&F Service wire PVC insulated and PVC sheathed stranded Aluminium conductor 10 sq mm 2 Core fixed to walls or suspended by insulating hanger not more than one meter apart including 4mm dia GI suspension wire and binding with 2mm dia new GI wire with reel insulator complete all as directed. | | 60 | RM |
|---|
| 134 | 130 | Taking down ceiling/exhaust fan including dismantling all necessary electrical connections to facilitate repairs to ceiling/wall complete all as directed. | | 6 | EACH |
|---|
| 135 | 131 | Hanging only/ Refixing ceiling/exhaust fan removed under item Srl No 130 above and connecting up including provision of cable from ceiling rose or connector to fan complete all as directed. | | 6 | EACH |
|---|
| 136 | 132 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized earth wire 4mm dia by means of galvanized iron or steel bolts nuts check nuts and washers and other end connected with earthing testing point including providing suitable testing points as directed including funnel, watering pipe of 20mm bore, light grade galvanized iron pipe, wire mesh charcoal of coal dust and common salt in alternative layer all around the earth electrode compacted thickness 15cm with concrete pit in PCC 1:3:6 type C1 50mm thick pre cast RCC 1:2:4 type B1 cover slab set in CM (1:4) re-enforcement with 8mm dia deformed bars @ 15cm C/C and suitable handle of 10mm dia MS round bars, including earth work in hard/dense soil as required complete all as shown in electrical plate No 3 of MES Schedule Part I and testing on completion all as specified and as directed. (Note: GI Earthing lead upto 7.5m in lenght is deemed to be included in the unit rate. The lead required beyond 7.5m shall be measured and paid for separately) | | 1 | EACH |
|---|