Current Status Of Bacterial Wilt And Detection Of Ralstonia Solanacearum Free Areas Under Potato Growing Districts To Facilitate The Export From West Bengal, BCKV, Mohanpur-West Bengal

Bidhan Chandra Krishi Viswavidyalaya has published Current Status Of Bacterial Wilt And Detection Of Ralstonia Solanacearum Free Areas Under Potato Growing Districts To Facilitate The Export From West Bengal. Submission Date for this Tender is 02-03-2020. Scientific Equipment Tenders in BCKV, Mohanpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

23626060
Current Status Of Bacterial Wilt And Detection Of Ralstonia Solanacearum Free Areas Under Potato Growing Districts To Facilitate The Export From West Bengal
Open Tender
Indian
West Bengal
BCKV, Mohanpur
02-03-2020

Tender Details

Current Status Of Bacterial Wilt And Detection Of Ralstonia Solanacearum Free Areas Under Potato Growing Districts To Facilitate The Export From West Bengal - 2 Mini Horizontal Electrophoresis System With Power Pack : Technical Specifications N• A Horizontal Electrophoresis System Should Be Able To Run The Gel Size Of 7 X 10Cm & 7 X 7 Cm, And 7 X 10 Cm; The Gel Tray Should Be Supplied Along With The Gel Tank With Safety Lid. N• The Supplied Gel Trays Should Be Uv Proof And The Trays Can Be Directly Kept On The Uv Transilluminator And Should Have An Integrated Fluorescent Ruler In The Tray. The Ruler Should Get Illuminated On Exposure To Uv Light For Easy And Safe Calculation Of The Band Movements. N• A System Should Include Tape Free Gel Casting Module For Leak Free Operations. N• A System Should Include Two 1.5Mm Combs, 8- & 15-Well Fixed Height Combs Each. N• A System Should Have The Option For Adjustable Height Combs With Comb Holders. N• Migration Rate Of Bromophenol Blue Dye Should Be Similar To 4.5Cm / Hr ( At 75 V ) . N• A System Should Have A Lid With The Safety Banana Jacks, Which Breaks The Circuit When The Lid Is Running. N• Should Be Provided With A Bubble Leveler For Even Gel Casting. • The Gel Caster Should Have 3 Height Adjustable Screws For Balancing The Uneven Platforms For Uniform Gel Casting. N• The Electrodes Should Be Color Coded To Remove The Confusion Of Wrong Orientation. N• The Lid Should Have A Safety Option So That The Lid Cannot Be Closed In The Wrong Orientation. • The Lid Should Have A Integrated Cables To Connect It To The Power Pack Directly. N• A System Should Be Capable To Run Precast Ready Agarose Gels And Hand Cast Gels. Nbasic Power Supply: N• Programmable Power Supply Should Be Capable To Operate Four Electrophoresis Units Simultaneously For Four Identical Runs With Graphic Led Display. N• The Output Range Should Be 10-300 V , 0.4-400 Ma, 1-75 W . • Constant Voltage, Current Or Power With Automatic Crossover N• Memory Storage: 9 Programs , 9 Steps, Timer Control : 99 Hr, 59 Min • Automatic Power Up After Power Failure, Safety Features • No-Load Detection; Sudden Load Change Detection Nwarranty: Should Provide 2 Years Warranty. Nthe Quoted Model Should Have 30 Installation In Eastern India ( Details Should Provide ) . Nmanufacturing Authorization Must Be Attached With The Quotation. N N 3 Mini Vertical Gel Apparatus With Power Pack : Technical Specification N? High Throughput- Capable Of Running Up To 4 Mini Gel ( 8 X 7 Cm ) Simultaneously. N? Flexible- Capable Of Running Hand Cast As Well As Precast Gel. N? Running And Casting Module Should Be Different N? Interchangeable Module- Should Be Capable Of Using Blotting Module To Do Western Blotting. N? Leak Proof, Tape Free And Easy Assembly. N? Patented Flap Wing For Leak Proof Assembly. N? Permanently Bonded Spacer Plates For Leak Proof, Without Agarose Sealing & Taping Casting Of Gels. N? Casting Frame With Simple Cam Closure Mechanism That Gives Precision Alignment On Any Flat Surface. N? Side By Side Casting Stands That Allow Access To Both Gels Simultaneously. N? Patented Colored Sample Loading Guides To Prevent The Skipping Or Repeated Loading Lanes. N? Modular Design Can Be Used Do Western Blotting By Using The Blotting Module Only. N? Should Able To Run Gels In 15-20 Mins. N? Should Come With Buffer Dam. N? It Should Be Supplied With 10% Stain Free Fast Acrylamide Starter Kit Npower Supply Basic- N• Programmable Power Supply Should Be Capable To Operate Four Electrophoresis Units Simultaneously For Four Identical Runs With Graphic Led Display. N• The Output Range Should Be 10-300 V , 0.4-400 Ma, 1-75 W . N• Constant Voltage, Current Or Power With Automatic Crossover N• Memory Storage: 9 Programs , 9 Steps, Timer Control : 99 Hr, 59 Min N• Automatic Power Up After Power Failure, Safety Features: No-Load Detection; Sudden Load Change Detection. Nwarranty: Should Provide 2 Years Warranty. N N

Key Value

Document Fees
Refer document
EMD
INR 2000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Current status of bacterial wilt and detection of Ralstonia solanacearum free areas under potato growing districts to facilitate the export from west Bengal
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Electrical Items :
2 1.01 Mini Horizontal Electrophoresis system with power pack : Technical Specifications\n• A horizontal electrophoresis system should be able to run the gel size of 7 x 10cm & 7 X 7 cm, and 7 x 10 cm; the gel tray should be supplied along with the Gel tank with safety lid. \n• The supplied gel trays should be UV proof and the trays can be directly kept on the UV Transilluminator and should have an integrated fluorescent ruler in the tray. The ruler should get illuminated on exposure to UV Light for easy and safe calculation of the band movements. \n• A system should include tape free gel casting module for leak free operations. \n• A system should include two 1.5mm combs, 8- & 15-well fixed height combs each. \n• A system should have the option for adjustable height combs with comb holders. \n• Migration rate of Bromophenol Blue dye should be similar to 4.5cm/hr(at 75 V). \n• A system should have a lid with the safety banana Jacks, which breaks the circuit when the lid is running. \n• Should be provided with a bubble leveler for even gel casting. • The gel caster should have 3 height adjustable screws for balancing the uneven platforms for uniform gel casting. \n• The electrodes should be color coded to remove the confusion of wrong orientation. \n• The Lid should have a safety option so that the lid cannot be closed in the wrong orientation. • The Lid should have a integrated cables to connect it to the power pack directly. \n• A system should be capable to run precast ready agarose gels and Hand Cast gels. \nBasic power supply:\n• Programmable power supply should be capable to operate four electrophoresis units simultaneously for four identical runs with graphic LED display. \n• The output range should be 10-300 V , 0.4-400 mA, 1-75 W . • Constant voltage, current or Power with Automatic crossover \n• Memory storage: 9 programs , 9 steps, Timer Control : 99 hr, 59 min • Automatic Power up after Power failure, Safety features • No-load detection; sudden load change detection \nWarranty: Should provide 2 years warranty.\nThe quoted model should have 30 installation in eastern INDIA (details should provide).\nManufacturing authorization must be attached with the quotation.\n\n item1 1 Nos
3 1.02 Mini Vertical gel apparatus with power pack : Technical specification\n? High throughput- Capable of running up to 4 mini gel (8 X 7 Cm) simultaneously.\n? Flexible- Capable of running hand cast as well as precast gel. \n? Running and casting module should be different \n? Interchangeable module- Should be capable of using blotting module to do western blotting. \n? Leak proof, tape free and easy assembly. \n? Patented Flap wing for leak proof assembly. \n? Permanently bonded spacer plates for leak proof, without agarose sealing & taping casting of gels. \n? Casting frame with simple cam closure mechanism that gives precision alignment on any flat surface. \n? Side by side casting stands that allow access to both gels simultaneously. \n? Patented colored sample loading guides to prevent the skipping or repeated loading lanes. \n? Modular design can be used do western blotting by using the blotting module only. \n? Should able to run gels in 15-20 mins. \n? Should come with buffer dam. \n? It Should be Supplied with 10% Stain free Fast Acrylamide Starter Kit \nPower Supply Basic-\n• Programmable power supply should be capable to operate four electrophoresis units simultaneously for four identical runs with graphic LED display. \n• The output range should be 10-300 V , 0.4-400 mA, 1-75 W . \n• Constant voltage, current or Power with Automatic crossover \n• Memory storage: 9 programs , 9 steps, Timer Control : 99 hr, 59 min \n• Automatic Power up after Power failure, Safety features: No-load detection; sudden load change detection.\nWarranty: Should provide 2 years warranty.\n\n item2 1 Nos
Disclaimer :