Military Engineer Services-MES has published Repair And Maintenance Of Summer Appliances Including Refrigeration And Air Conditioner Under Ge Saugor. Submission Date for this Tender is 21-03-2020. Air Conditioner Tenders in Saugor Madhya Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 12-Mar-2020 | date | Date | 14-03-2020 |
2 | 16-Mar-2020 | Datescorrigendum | Date | 21-03-2020 |
Name of Work: REPAIR AND MAINT OF SUMMER APPLIANCES INCLUDING REFIRGERATION AND AIR CONDITIONER UNDER GE SAUGOR | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | AIR CONDITIONER WINDOW/SPLIT TYPE 1.5/2.0/3.0 TR | |||
2 | 1.01 | Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make from window type AC and S&F new compressor suitable for window AC of capacity 1.5 Ton complete all as specified and directed.\n Make:- Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 6 | Each Job | |
3 | 1.02 | All as per Srl item No.1.01 here in before but compressor suitable for window AC of capacity 2.0 Ton complete all as specified and directed. \nMake:- Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 4 | Each Job | |
4 | 1.03 | Dismantling and taking out the existing old unserviceable compressor hermetically sealed unit of any make from split type AC and S&F new compressor suitable for Split AC of capacity 1.5 Ton complete all as specified and directed.\n Make:- Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 15 | Each Job | |
5 | 1.04 | All as per Srl item No.1.03 here in before but compressor suitable for Split AC of capacity 2.0 Ton complete all as specified and directed. \nMake:- Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 7 | Each Job | |
6 | 1.05 | All as per Srl item No.1.03 here in before but compressor suitable for Split AC of capacity 3.0 Ton complete all as specified and directed.\n Make:- Godrej/LG/Samsung/Vidiocon/Hitachi/Carrier/Kirloskar | 3 | Each Job | |
7 | 1.06 | M&L for testing leakage in system window type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed | 5 | Each Job | |
8 | 1.07 | All as per item No 1.06 here-in-before but Air conditioner of 2 ton capacity complete all as specified and directed | 3 | Each Job | |
9 | 1.08 | M&L for testing leakage in system Split type Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system complete all as specified and directed | 15 | Each Job | |
10 | 1.09 | All as per Srl item No 1.08 here-in-before but Split type Air conditioner of 2.0 ton capacity complete all as specified and directed | 10 | Each Job | |
11 | 1.1 | All as per Srl item No 1.08 here-in-before but Split type Air conditioner of 3.00 ton capacity complete all as specified and directed | 3 | Each Job | |
12 | 1.11 | M&L for servicing of Air conditioning of any capacity including air Filter Cleaning, Condenser and Evaporator coil Cleaning, insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water complete all as specified and directed.Note:-(i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (ii) Spare parts alongwith Refrigerant gas shall be measured and paid separately | 105 | Each Job | |
13 | 1.12 | Supply only Starting capacitor of capacity 80/100 MFD complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 20 | Each | |
14 | 1.13 | Supply only Starting capacitor of capacity 100/120 MFD complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 20 | Each | |
15 | 1.14 | Supply only Starting capacitor of capacity 120/140 MFD complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 18 | Each | |
16 | 1.15 | Supply only Starting capacitor of capacity 160/180 MFD complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 15 | Each | |
17 | 1.16 | Supply only Condenser capacity of 5/6 MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian | 20 | Each | |
18 | 1.17 | Supply only Condenser capacity of 10 MFD complete all as specified and directed.\n Make: Univers/Sarada/Usha/Asian | 21 | Each | |
19 | 1.18 | Supply only Condenser capacity of 25 MFD complete all as specified and directed.\n Make: Univers/Sarada/Usha/Asian | 15 | Each | |
20 | 1.19 | Supply only Condenser capacity of 36 MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian | 15 | Each | |
21 | 1.2 | Supply only Condenser capacity of 45 MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian | 16 | Each | |
22 | 1.21 | Supply only Condenser capacity of 50 MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian | 15 | Each | |
23 | 1.22 | Supply only Condenser capacity of 55 MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian | 15 | Each | |
24 | 1.23 | Supply only Condenser capacity of 60MFD complete all as specified and directed. \nMake: Univers/Sarada/Usha/Asian. | 10 | Each | |
25 | 1.24 | Supply only Cooling Coil suitable for 1.5 Ton Capacity Window AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 4 | Each | |
26 | 1.25 | Supply only Cooling Coil suitable for 2.0Ton Capacity Window AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 3 | Each | |
27 | 1.26 | Supply only Cooling Coil suitable for 1.5 Ton Capacity Split AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 8 | Each | |
28 | 1.27 | Supply only Cooling Coil suitable for 2.0 Ton Capacity Split AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 3 | Each | |
29 | 1.28 | Supply only Cooling Coil suitable for 3.0 Ton Capacity Split AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 1 | Each | |
30 | 1.29 | Supply only Swing motor suitable for 1.5 Ton Capacity Window type Air Conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 2 | Each | |
31 | 1.3 | Supply only Swing motor suitable for 2.0 Ton Capacity Window type Air Conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 2 | Each | |
32 | 1.31 | Supply only Swing motor suitable for 1.5 Ton Capacity Split type Air Conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 5 | Each | |
33 | 1.32 | Supply only Swing motor suitable for 2.0 Ton Capacity Split type Air Conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 3 | Each | |
34 | 1.33 | Supply only Swing motor suitable for 3.0 Ton Capacity Split type Air Conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 1 | Each | |
35 | 1.34 | Supply only Over load relay suitable for 1.5/2.0 Ton Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 4 | Each | |
36 | 1.35 | Supply only Over load relay suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 5 | Each | |
37 | 1.36 | Supply only Over load relay suitable for 3.0 Ton Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 1 | Each | |
38 | 1.37 | Supply only PVC Front gril suitable for Window type AC of any Make suitable for 1.5/2.0Ton window AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 15 | Each | |
39 | 1.38 | Supply only Electric blower motor suitable for 1.5 Ton Capacity Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 12 | Each | |
40 | 1.39 | All as per item No. 1.38 here in before but suitable for 2.0 Ton Capacity Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 5 | Each | |
41 | 1.4 | All as per item No.1.38 here in before but suitable for 1.5 Ton Split AC (Evaporator/Condenser) complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 20 | Each | |
42 | 1.41 | All as per item No. 1.38 here in before but suitable for 2.0 Ton Split AC (Evaporator/Condenser) complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 12 | Each | |
43 | 1.42 | All as per item No. 1.38 here in before but suitable for 3.0 Ton Split AC (Evaporator/Condenser) complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 2 | Each | |
44 | 1.43 | Supply only blower motor fan blade suitable for 1.5/2.0 Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 10 | Each | |
45 | 1.44 | Supply only blower motor fan blade suitable for 1.5/2.0 Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 6 | Each | |
46 | 1.45 | Supply only blower motor fan blade suitable for 3.0 Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 1 | Each | |
47 | 1.46 | Supply only condenser motor with fan blade suitable for 1.5 Ton capacity Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 10 | Each | |
48 | 1.47 | Supply only condenser motor with fan blade suitable for 2.0Ton capacity Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 6 | Each | |
49 | 1.48 | Supply only condenser motor with fan blade suitable for 1.5 Ton capacity Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 20 | Each | |
50 | 1.49 | Supply only condenser motor with fan blade suitable for 2.0 Suitable for Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 12 | Each | |
51 | 1.5 | Supply only condenser motor with fan blade suitable for 3.0 Suitable for Split type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 1 | Each | |
52 | 1.51 | Supply only thermostat switch with knob suitable for AC of any capacity complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 30 | Each | |
53 | 1.52 | Supply only Air Filter Suitable for 1.5/2.0/3.0 Ton Capacity Window/Split type Air conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 25 | Each | |
54 | 1.53 | Supply only capillary tube length as per existing size suitable for 1.5/2.0/3.0 Ton Capacity Air conditioner complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 20 | Each | |
55 | 1.54 | Supply only PCB Circuit with remote control suitable for any make and capacity of 1.5/2.0 Ton Window type AC complete all as specified and directed. Make: Renutrol/Indfos/Kelvinator | 6 | Each | |
56 | 1.55 | Supply only PCB Circuit with remote control suitable for any make and Capacity of 1.5/2.0/3.0 split type capacity Air Conditioner complete all as specified and directed. \nMake: Renutrol/Indfos/Kelvinator | 15 | Each | |
57 | 1.56 | Supply only metal top with bottom suitable for 16 Amps Capacity 1.5/2.0/3.0 Ton Capacity Air conditioner Make: Anchor/Havells/Philips/Polycab | 50 | Each | |
58 | 1.57 | Supply only Oxyzen Gas complete all as specified and directed | 5 | Kg | |
59 | 1.58 | Supply only Brazing rod complete all as specified and directed | 15 | Each | |
60 | 1.59 | Supply only Carbite stone complete all as specified and directed | 10 | Kg | |
61 | 1.6 | S&F in repairs suction pipe suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed | 15 | Each | |
62 | 1.61 | S&F in repairs damaged Insulation of size 1/4&3/8 for Split AC complete all as specified and directed | 100 | Rm | |
63 | 1.62 | S&F in repairs damaged Insulation of size 1/2 & 5/8 for Split AC complete complete all as specified and directed | 100 | Rm | |
64 | 1.63 | S&F in repairs rubber bush suitable for 1.5/2.0/3.0 ton capacity Suitable for Air conditioner as per sample complete all as specified and directed | 10 | Each set | |
65 | 1.64 | S&F in repairs copper Tube of size 1/4 suitable for any type and any capacity Air conditioner complete all as specified and directed | 20 | Rm | |
66 | 1.65 | S&F in repairs copper Tube of size 3/8suitable for any type and any capacity Air conditioner complete all as specified and directed | 25 | Rm | |
67 | 1.66 | S&F in repairs plug nut of size 1/2 suitable for any type and any capacity Air conditioner complete all as specified and directed | 10 | Each | |
68 | 1.67 | S&F in repairs plug nut of size 5/8 suitable for any type and any capacity Air conditioner complete all as specified and directed | 10 | Each | |
69 | 1.68 | Taking out and shifting new location and refixing both indoor and outdoor unit of split type Air conditioning electrically driven 230V/250V ,AC 50 Hz capacity 1.5/2.0/3.0 Ton in wall with rowl plugs including making holes for inlet /outlet in the wall with 50mmX50mmX6mm size of agle iron for foundation of condensing unit as per suitable size and making good existing surface including insulation of tubing with expanded polythene foam insulation tubing and making necessary connection including M&L for unplastiised PVC pipe medium duly 20 mm dia for draining out condensed water all as required and directed including necessary connection through voltage stabilizer complete all as specified and directed. | 25 | Each Job | |
70 | 1.69 | M&L for repairs to walk in cooler 1.5 Ton and repair/replacement the compressor, filter including gas charging and general service complete all as specified and directed. | 1 | Each Job | |
71 | 2 | WATER COOLER | |||
72 | 2.01 | Dismantling and taking out the existing old unsv compressor sealed unit from Water cooler and S&F new compressor copper wound unit for operation on single phase, 230 V, 50 Hz, AC supply & confirm to IS-1067 Part-I, suitable for Water cooler of cooling capacity 40/80 ltrs/hrs and complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 6 | Each Job | |
73 | 2.02 | All as per item No.2.01 here in before but compressor suitable for Water Cooler of cooling capacity 60/120 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 8 | Each Job | |
74 | 2.03 | All as per item No.2.01 here in before but compressor suitable for Water Cooler of cooling capacity 60/80 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 4 | Each Job | |
75 | 2.04 | All as per item No.2.01 here in before but compressor suitable for Water Cooler of cooling capacity 80/100 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 8 | Each Job | |
76 | 2.05 | All as per item No.2.01 here in before but compressor suitable for Water Cooler of cooling capacity 100/120 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 4 | Each Job | |
77 | 2.06 | All as per item No.2.01 here in before but compressor suitable for Water Cooler of cooling capacity 80/40 ltrs/hrs complete all as specified and directed. Make-Kirloskar/Blue star/LG/Tecumseh | 5 | Each Job | |
78 | 2.07 | M&L Checking the unserviceable water cooler of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (ii). Spare parts shall be measured and paid separately | 50 | Each Job | |
79 | 2.08 | Supply only condensor motor SP,230V, 50 Hz suitable for 40/80 ltr capacity water cooler as per existng sample complete all as specified and directed. Make:LG/Blue star/Vediocon | 10 | Each | |
80 | 2.09 | All as per item here in before but suitable for 150/180,60/120 ltr capacity water cooler as per existng sample complete all as specified and directe. Make:LG/Blue star/Vediocon | 10 | Each | |
81 | 2.1 | Supply only condenser fan blade suitable for 150/180,60/120 and 40/80 capacity water cooler complete all as specified and directed | 7 | Each | |
82 | 2.11 | Supply only capacitor for condenser motor suitable for any capacity, size complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 10 | Each | |
83 | 2.12 | Supply only Starting Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 25 | Each | |
84 | 2.13 | Supply only Running Capacitor suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 30 | Each | |
85 | 2.14 | Supply only Starting relay current type suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed. Make: Univers/Sarada/Usha/Asian | 15 | Each | |
86 | 2.15 | Supply only Over load Protector suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed | 20 | Each | |
87 | 2.16 | Supply only Thermostat switch with knob suitable for compressor of water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed | 25 | Each | |
88 | 2.17 | Supply only PVC float valve assy alongwith ball with complete accessories for water cooler any capacity of size 15 mm dia complete all as specified and directed . Make: Prayag/leader/Supreme | 25 | Each | |
89 | 2.18 | Supply only Self closing water tap 15 mm dia chromium plated inner/outer thread for water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed. Make: Waterman/Leader/Prayag/Leader | 30 | Each | |
90 | 2.19 | Supply only Air Filter Suitable for water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed | 20 | Each | |
91 | 2.2 | Supply only Capillary tube of suitable length as per existing size for water cooler 150/180,60/120 and 40/80 capacity complete all as specified and directed | 25 | Each | |
92 | 2.21 | M&L for testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. and repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system complete all as specified and directed | 5 | Each Job | |
93 | 2.22 | M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket complete all as specified and directed | 5 | Each Job | |
94 | 2.23 | S&F in repairs water cooler inner tank made of stainless steel as per existing capacity & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer complete all as specified and directed | 5 | Each Job | |
95 | 3 | REFRIGERATOR | |||
96 | 3.01 | M&L for removing burnt/defective sealed compressor unit of any make from any type and Capacity of 165 to 200 Ltrs refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. Make- Godrej/Vidiocon/Whirlpool/LG/Carrier/Daikin | 19 | Each Job | |
97 | 3.02 | All as per item No.3.01 here in before but compressor suitable for refrigerator capacity of 286 to 320 Ltrs complete all as specified and directed. Make- Godrej/Vidiocon/Whirlpool/LG/Carrier/Daikin | 13 | Each Job | |
98 | 3.03 | M&L for checking the unserviceable Refirgerator of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. Note: (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (ii). Spare parts shall be measured and paid separately | 60 | Each job | |
99 | 3.04 | Supply only magnetic door gasket suitable for 165 to 200 ltrs capacity Refrigerator complete all as specified and directed | 15 | Each | |
100 | 3.05 | Supply only magnetic door gasket suitable for 286/320 Ltrs capacity Refigerator complete all as specified and directed | 10 | Each | |
101 | 3.06 | Supply only Freezer suitable for 165 to 200 ltrs capacity Refrigerator complete all as specified and directed | 10 | Each | |
102 | 3.07 | Supply only Freezer suitable for 286/310 Ltrs capacity Refigerator complete all as specified and directed | 15 | Each | |
103 | 3.08 | Supply only Relay current type and over load protector suitable for compressor complete all as specified and directed Make: Ranutrol/Voltas/LG | 15 | Each | |
104 | 3.09 | Supply only Thermostat auto defrost type suitable for any make and any capacity Refrigerator complete all as specified and directed. Make: Danfos/Ind Foss/renutrol | 14 | Each | |
105 | 3.1 | Supply only Air Filter suitable for for any make and any capacity Refrigerator complete all as specified and directed | 15 | Each | |
106 | 3.11 | Supply only Capillary tube of suitable length as per existing size for refrigerator any make and any capacity complete all as specified and directed | 20 | Each | |
107 | 3.12 | Supply only Vegitable tray as per sample and suitable for refrigertator any type and any make complete all as specified and directed | 14 | Each | |
108 | 3.13 | Supply only PVC Stand for Refigerator capacity any make and any capacity as per sample complete all as specified and directed | 25 | Each | |
109 | 4 | DEEP FREEZER | |||
110 | 4.01 | M&L for removing burnt/defective sealed compressor unit of any make from Capacity 155 to 200 Ltr of Deep freezer by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit complete all as specified and directed. Make-Tecumesh/Godrej/Voltas/Blue star/ whirlpool/ LG | 2 | Each Job | |
111 | 4.02 | All as per item No.38.00 here in before but compressor suitable for Deep freezer capacity of 250 to 320 Ltrs complete all as specified and directed. Make-Tecumesh/Godrej/Voltas/Blue star/ whirlpool/ LG | 7 | Each Job | |
112 | 4.03 | M&L for testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system complete all as specified and directed | 6 | Each Job | |
113 | 4.04 | M&L Checking the unserviceable Deep Freezer of any make, size and capacity, making it serviceable by tightening the connection, checking power point and making it functional, replacement of screws, small pieces of wire, etc complete all as specified and directed. Note:- petty stores such as insulation tape, screws, small pieces of wires, plug top etc shall be provided by the Contractor without any extra cost to the department. (ii). Spare parts shall be measured and paid separately | 10 | Each Job | |
114 | 4.05 | Supply only Relay current type and over load protector suitable for compressor complete all as specified and directed. Make: Danfos/Ind Foss/renutrol | 15 | Each | |
115 | 4.06 | Supply only Thermostat auto defrost type suitable for any make and any capacity Deep Freezer complete all as specified and directed | 15 | Each | |
116 | 4.07 | Drier filter complete set suitable for any make and any capacity Deep Freezer complete all as specified and directed | 14 | Each | |
117 | 4.08 | Supply only Indicating lamp (Red and Green) 230V complete suitable for any make and any capacity Deep Freezer as per sample complete all as specified and directed | 10 | Each | |
118 | 4.09 | Supply only Capillary tube of suitable length as per existing size for Deep freezer any make and any capacity complete all as specified and directed | 18 | Each | |
119 | 4.1 | Supply only Starting relay suitable for 310/320 ltrs capacity Deep freezer complete all as specified and directed | 15 | Each | |
120 | 4.11 | Supply only Condenser motor (Rotary fan) suitable for any type and any capacity deep freezer complete all as specified and directed. Make; AUE/Cool Blow/Universal | 10 | Each | |
121 | 4.12 | Supply only Starting capacitor suitable for Deep freezer suitable for any type and any capacity deep freezer complete all as specified and directed | 10 | Each | |
122 | 5 | DESERT COOLER | |||
123 | 5.01 | Dismantling and taking out the existing old unsv fan motor with blade from Desert coolers and S&F new fan motor with blade of capacity 1/6 HP (125 W), 230 V, 50 Hz, SP, AC sup confirming to IS-996/79 (motor only) with mounting accessories and connection complete suitable for D/cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed Make- Khaitan/Cool Blow/Dynamic or equivalent. Note: (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed (ii). Spare parts shall be measured and paid separately | 10 | Each Job | |
124 | 5.02 | M&L for repair to Desert cooler dismantling the unserviceable parts of Desrt coolers,checking the general servicing complete all as specified and directed. Note: (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department.complete all as specified and directed (ii). Spare parts shall be measured and paid separately | 70 | Each Job | |
125 | 5.03 | Supply only Water circulating submesible pump, 1300 RPM, SP, 230V, 50Hz 1.5M head , discharge 7.0 Ltrs/hr complete all as specified and directed. Make: TESLA/TEXMO or equivalent | 50 | Each | |
126 | 5.04 | Supply only Filter pad made out of wooden wool suitalbe for Air grills of desert cooler as per existing size complete all as specified and directed. Make: Usha/Asian/KEIL | 25 | Set of 3 | |
127 | 5.05 | Supply only Capacitor for 2.5/4MFD complete all as specified and directed. Make: Usha/Asian/KEIL | 50 | Each | |
128 | 5.06 | Supply only Capacitor for 5/6 MFD complete all as specified and directed. Make: Usha/Asian/KEIL | 45 | Each | |
129 | 5.07 | Supply only Front panel of dimension as per existing size suitable for desert cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed. | 10 | Each | |
130 | 5.08 | Supply only Panels suitable for as per existing size for desert cooler of capacity 4000/5000/6000 Cum per hrs complete all as specified and directed. | 10 | Set of 3 | |
131 | 5.09 | Supply only PVC Flexible hose suitable for desert cooler cooling system complete all as specified and directed. | 30 | Rm | |
132 | 5.1 | Supply only PVC Fan Blade suitable for 3000/4000/5000/6000 as per sample complete all as specified and directed. | 20 | Each | |
133 | 5.11 | Supply only Selector switch as per existing model and size complete all as specified and directed. | 25 | Each | |
134 | 5.12 | Supply only Bolt, nut with washers as per sample complete all as specified and directed. | 2 | Kg | |
135 | 5.13 | Supply only PVC Connector i.e (Elbow, Tee,4 way etc) complete all as specified and directed. | 50 | Each | |
136 | 6 | VOLTAGE STABILZER | |||
137 | 6.01 | M&L for repair to voltage stablizer of capacity 0.5/1.0/2.0KVA, dismantling the unserviceable parts of voltage stablizer ,checking the general servicing complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (ii). Spare parts shall be measured and paid separately | 40 | Each Job | |
138 | 6.02 | All as per item No.6.01 here in before but voltage Stablizer of capacity 3/4/5 KVA complete all as specified and directed. Note:- (i) Petty stores such as insulation tape, screws, small pieces of wires,plug top etc shall be provided by the Contractor without any extra cost to the department. (ii). Spare parts shall be measured and paid separately | 40 | Each Job | |
139 | 6.03 | Supply only Relay for the existing capacity of stabilizer any make and any capacity complete all as specified and directed | 10 | Each | |
140 | 6.04 | Supply only Trigger transformer for the existing capacity of stabilizer any make and any capacity complete all as specified and directed | 10 | Each | |
141 | 6.05 | Supply only Circuite plate for the existing capacity of stabilizer any make and any capacity complete all as specified and directed | 10 | Each | |
142 | 6.06 | Supply only Cut out of 15 Amps for the existing capacity of stabilizer any make and any capacity complete all as specified and directed | 10 | Each | |
143 | 6.07 | Supply only Volt meter indicating 100-300 Volt for the existing capacity of stabilizer any make and any capacity complete all as specified and directed | 10 | Each | |
144 | 6.08 | Supply only Transformer suitable for 0.5/1.0 Voltage Stabilizer complete all as specified and directed | 5 | Each | |
145 | 6.09 | Supply only Transformer suitable for 2/3 KVA Voltage Stabilizer complete all as specified and directed | 5 | Each | |
146 | 6.1 | Supply only Transformer suitable for 4/5 KVA Voltage Stabilizer complete all as specified and directed | 5 | Each | |
147 | 6.11 | Supply only PVC insulated and PVC over all covered cord cable copper conductor 3 core of size 4 Sqmm complete all as specified and directed. Make- Plaza/Havells/ Finolex. | 100 | Rm | |
148 | 6.12 | Taking down the unserviceable Sheet metal enclosure and supply and fix Sheet metal enclosures with flush mounted type ply and socket with 240 V SP MCB 20 amps capacity complete all as specified and directed. Make: ABB/Legrand/Havells or Equivalent | 20 | Each | |
149 | 6.13 | Taking out the Unserviceable defective Voltage Stabilizer of capacity 3.0 KVA and S&F of the new Voltage Stabilizer with connected wiring with accessories complete all as specified and directed. Make: V GUARD/VOLTAS/VENUS | 7 | Each | |
150 | 6.14 | All as item No. 51 here in before but 4/5 KVA Capacity complete all as specified and directed. \nMake: V GUARD/VOLTAS/VENUS | 8 | Each | |
151 | 6.15 | Labour only for charging refrigerent gas R-22/R-410A/R-134(a) for Refrigerator/Deep freezer/Water cooler/Window and split type Air conditioner after duly rectifying leakages by welding/brazing and testng by charging N2 gas for 24 hours complete all as specified and directed . Note:- Refrigerant gas shall be measured and paid separately under relabent items of this schedule | 210 | Each Job | |
152 | 6.16 | M&L for Charging of gas R-22 as exhisting Split/ window type Air Conditioner and water cooler anytype and any capacity complete all as specified and directed by Engineer-in-Charge | 120 | Kg | |
153 | 6.17 | M&L for Charging of gas R-410A as exhisting Split/ window type Air Conditioner and water cooler anytype and any capacity complete all as specified and directed by Engineer-in-Charge | 50 | Kg | |
154 | 6.18 | M&L for charging of Refrigerant gas R-134(a)in refrigerator and deep freezer of any capacity complete all as specified and directed at site by the Engr-in-Charge. | 55 | Kg | |
155 | 6.19 | Taking down carefully unserviceable Sub main wiring including unserviceable fittings such as switches, ceiling roses, regulators etc complete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed by Engineer-in charge. | 130 | Rm | |
156 | 6.2 | M&L for sub main wiring with 6 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed.complete all as specified and as directed by Engineer-in charge. Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire will be measured as one length.) | 60 | Rm | |
157 | 6.21 | M&L for sub main wiring with 4 Sqmm (Nominal area) with two runs (Red for phase and Black for neutral) of single core, PVC insulated, multistranded, unsheathed, copper conductor cables 1100 V grade drawn through PVC conduits/casing-caping fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor green in colour as earth wire and duly connected to earth point complete as specified and directed.complete all as specified and as directed by Engineer-in charge. Note :- (a) PVC conduits/casing caping and Two runs cables and one run of earth wire shall be measured as one length. | 40 | Rm | |
158 | 6.22 | M&L point wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) complete fixed to walls /ceiling etc. with and including 2.5Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including PVC terminal box fixed with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light point controlled by one ,one way switches complete all as specified and as directed | 30 | Rm | |
159 | 6.23 | M&L for fabrication of angle iron stand suitable for housing Desert cooler/Water cooler/AC stand including painting with two coats of synthetic enamelled paint over a coat of red oxide primer including mounting on wall with suitable size nut bolt and grounting and making good disturbed surface complete all as specified and directed. | 500 | Kg |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy