Construction Of Compound Wall At Water Treatment Plant At Rakholi Wd-Ii ( 1St Call )

Tender Notice

23577657
Construction Of Compound Wall At Water Treatment Plant At Rakholi Wd-Ii ( 1St Call )
Indian
Dadra And Nagar Haveli
11-02-2020
27-02-2020
03-03-2020

Tender Details

Construction Of Compound Wall At Water Treatment Plant At Rakholi Wd-Ii ( 1St Call )

Key Value

Document Fees
INR 1000 /-
EMD
INR 167600.00 /-
Tender Value
INR 83.77 Lakhs /-

BOQ Items

Name of Work: Construction of Compound wall and Internal road for Water Treatment Plant at Rakholi (WD-II) (1st call)
Sl. No. Item Description Item Code / Make Quantity Units
1 1.01 Excavation for foundation including sorting out and stacking of useful materials and disposing off the excavated stuff up to 50 Meter lead for dense or Hard soil. Depth up to 1.50m 747 One Cubic Meter
2 1.02 Depth from 1.50 m to 3.00m 744 One Cubic Meter
3 2 Providing and laying cement concrete 1:3:6 (1 cement: 3 sands: 6 graded stone aggregates 20 nominal size) and curing complete including cost of formwork for foundation and plinth 53 One Cubic Meter
4 3.01 Providing and laying in controlled cement concrete M-30 and curing complete excluding the cost of formwork and reinforcement for reinforcement concrete works as per specification and direction of Engineer-in-charge.\n(Note :- Minimum Cement content considered in this item is @ 320 kg/cum as per IS -456-2000. (A) Footing 94 One Cubic Meter
5 3.02 RCC Column from Footing/ RT wall top to up to Finish Ground Level For Compound Wall ( AB to HA ) 45 One Cubic Meter
6 3.03 Column Above Ground Beam up to top of Compound Wall 45 One Cubic Meter
7 3.04 Ground Beam 76 One Cubic Meter
8 3.05 Coping 20 One Cubic Meter
9 4 Providing IS marked TMT FE - 500D bar reinforcement for RCC work including bending & placing in position complete up to floor two level. 26568 One Killo Gram
10 5.01 Providing formwork with sheathing steel sheets so as to give a fair finish including centering shuttering strutting and propping etc. Height of propping and centering below supporting floor to ceiling not exceeding 4 M. and removal of the same for in situ reinforced concrete and plain concrete work in. Footing (4 X 1.20 = 4.80) 312 One Square Meter
11 5.02 COLUMN 1193 One Square Meter
12 5.03 GROUND BEAM (Total Length) 502 One Square Meter
13 5.04 COPING (Total Length) 126 One Square Meter
14 6 Providing and laying 12 mm thick pre-moulded asphalt filler joints as per drawing and as directed 42 One Square Meter
15 7 Filling in trenches with available excavated earth (excluding rock in trenches plinth, sides of foundations etc. in layer not exceeding 20 cm in depth consolidating each desposalite layer by ramming and watering.) 1221 One Cubic Meter
16 8 Brick work using common burnt clay building bricks having crushing strength not less than 35 kg / sq. cm. at all elevation/ above plinth level in cement mortar 1:6 (1 - cement : 6 - fine sand) - with Conventional Bricks 301 One Cubic Meter
17 9 Providing 10 mm thick plaster in single coat on brick / concrete walls for inside / outside plastering up to floor two level and sand face / finished even and smooth in cement mortar 1:3 (1 - cement : 3 - sand) 3614 One Square Meter
18 10 Providing and applying 20 mm thick sand faced double coat cement plaster on walls or similar surfaces consisting of 12 mm thick backing cost of CM 1:3 (1 cement: 3 sand) and 8 cm thick finishing cost of CM 1:1 (1 cement :1 sand) etc complete. 123 One Square Meter
19 11 Finishing wall with weather proof exterior emulsion paint on wall surfaces (Two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powered materials. Etc. Complete 3661 One Square Meter
20 12 Steel work welded in built up sections, frame work including cutting , hoisting , fixing in position and applying a priming coat of red oxide of red lead paint & Two coat of enamel paint. For angle 50x 50x 6mm to be fixed in column of compound wall and MS tube, square bar etc. complete as per drawing and specification. 1458 One Killo Gram
21 13 Providing and fixing SLIDING COMPOUND GATE of M.S. Rectangular hollow section 150mm x 40mm x 5mm and 100mm x 40mm x 5mm and vertical 12mm M.S. round bar placed at 10mm C/C with frame and providing of 100mm x 6mm thick M.S. flat in middle of the vertical bar and half ring at bottom and top etc. with providing and fixing of WICKET GATE IN GATE including fixture and fastenings, locking arrangements and fixing in position in plumb including priming coat of red oxide paint and tow coat of approved quality oil paint etc. as per drawing and direction etc. complete. Gate 14 One Square Meter
22 14 Providing material & labour for supplying and fixing Galvanised steel Barbed wire (I.S. 278-1982 Type I) weighting 9.80 Kg./100 mts. (Min) straining and fixing to any type of standard rails straining bolts including curing with and provision of galvanised mild steel wires staples or steel pains etc. as desired (posts struts and concrete shall be paid separetely). 3726 One Running Meter
23 15 Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on road side slope as directed with all required lead and lift as per specification. 938.61 One Cubic Meter
24 16 Providing, laying and spreading of compacted thickness 100mm of Natural Sand and Gravel to compact to the required density with 8 - 10 tonne vibratory roller , maintaining the required slope & grade during the operation as approved by the engineer in charge & watering to the proper moisture content and sprinkled with the help of truck mounted water tank fitted with suitable arrangement etc completed as per specification . 148.75 One Cubic Meter
25 17.01 Providing & laying of specified compacted thickness Granular sub base (GSB) in specified grading in table 400-1 of the specification MORT&H and compactor to the required density with 8 - 10 tonne vibratory roller with plain drum or heavy pneumatic tyred roller of minimum 200 to 300 KN weight in all seasons as per MORT&H , maintaining the required slope & grade during the operation as approved by the engineer in charge & watering to the proper moisture content and sprinkled with the help of truck mounted water tank fitted with suitable arrangement .( fully saturated having CBR value greater or equal to 30) Garding ll 214.2 One Cubic Meter
26 17.02 Garding lll 214.2 One Cubic Meter
27 18 Providing & laying built up spray grout 150mm thick in two layer compacted with asphalt of VG-10 @ 1.99% by weight of mix for mixing and 2.5 Kg/10 Sq.m. for tack coat and using B.T. chips gradation as per specification including cleaning and heating asphalt premix materials by hot mix process in proper gradation and laying with paver finisher as per specifications and consolidation work with vibratory roller including cost of materials, labours, equipment and plant, fuel and oil etc. complete. 428.4 One Matric Tonne
28 19 Providing and laying bituminous macadam compacted minimum thickness at any point should not be less than 50 mm with 60-90 TPH hot mix plant producing an average output of 60 tonnes per hour, tack coat at the rate of 2.50 kg/ 10 m2 of Bitumenous Emulsion RS1 grade, Bitumen Grade VG-30 in mix at the rate of minimum 3.40 % by weight or as per design mix, using crushed aggregates of grading -2 premixed with bituminous binder, transported to site, laid over a previously prepared surface with approved self propelled paving machine equipped with an electronic sensing device paver finisher with sensor control to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction 157.08 One Matric Tonne
29 20 Providing and laying 30 mm thick bituminous concrete with 60-90 TPH hot mix plant producing an average output of 60 tonnes per hour, tack coat at the rate of 2.50 kg/ 10 m2 of Bituminous Emulsion RS1 grade, Bitumen Grade VG-30 in premixed with minimum bituminous binder @ 5.40 per cent of mix using crushed aggregates of grading II and filler transporting the hot mix to work site, laying with a approved self propelled paving machine equipped with an electronic sensing device paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects 103.671 One Matric Tonne
30 21 Providing and laying cement concrete 1:3:6 (1 cement : 3 Coarse sand : 6 crushed stone aggregate 20 mm nominal size) including cost of Curing, Form work etc complete as per specification and drawing for PCC for kerb and below paver block etc complete as per specification. 107 One Cubic Meter
31 22 Providing and fixing pre-cast rubber dye inter lockiing cement concrete block of approved shape and design having 60 mm thickness with grade of concrete M250 pnumatic compressed by mechanically pressed and as per approved design including 75 mm sand layer for leveling and filling the joint with sand in proper line and level etc. complete. 1070 One Square Meter
32 23 Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work in foundations, footings, base of columns and mass concrete. 2 One Cubic Meter
33 24.01 Providing & laying controlled cement concrete M250 and curing complete including the cost of formwork but excluding the cost of reinforcement for reinforced concrete work up to floor two level. (A) COLUMNS 3 One Cubic Meter
34 24.02 (B) BEAMS 3 One Cubic Meter
35 24.03 (C) chhajja 1 One Cubic Meter
36 24.04 (D) SLAB 2 One Cubic Meter
37 25 Providing throating or plaster drip & moulding to RCC Chhajja 7.2 One Running Meter
38 26 Providing and laying polished kota stone slab flooring over 20 mm (average) thick base of cement mortar 1:6 (1 cement: 6 sand) laid over and joined with grey cement slurry including and polishing etc. complete. (A) 25 mm thick 9 One Square Meter
39 27 Providing and fixing 35 mm thick shutters, for doors, windows and clear storey windows including indian teakwood frames 12 cm x 7 cm including anodized aluminium fixtures and fastenings including primer coat of approved quality and two coats of oil painting etc. complete. Fully Panelled. 2.1 One Square Meter
40 28 Providing and fixing window having extruded aluminium colour powder coated section frame main outer size 95 mm x 24 mm x 1.17 mm (of Jindal section no: 2459 @ wt. of 0.738 kg/mt.), horizontal three track member size 92 mm x 31.75 mm x 1.30 mm (of Jindal section no: 8688 @ wt. of 1.07 kg/mt.), vertical member of size 92 mm x 31.75 mm x 1.50 mm (of Jindal section no: 8933 @ wt. of 1.06 kg/mt.), with sliding shutter of horizontal member size 40 mm x 18 mm x 1.29 mm (of Jindal section no: 8947 @ wt. of 0.456 kg/mt.), vertical member of size 40 mm x 18 mm x 1.29 mm (of Jindal section no: 8949 @ wt. of 0.456 kg/mt.), with 5 mm thick transparent bronze colour tinted float glass with powder coated aluminium fitting and fixtures and transparent silicon sealant glass fixing to frame as per details etc. 3.6 One Square Meter
41 29 Distempering two coats with oil bound washable distemper of approved brand & manufacture & of required shade on wall surface to give an even shade over and & incl. a priming coat of alkali resistance primer of approved brand after thoroughly brushing the surface to give an even shade after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even and smooth.( Qty. As per Iteam no. 30) 31 One Square Meter
42 30 Providing and applying finishing wall or similar surfaces with water proofing cement paint (three coats) at all floor level of approved brand and manufacture and in required shape, even shade after thoroughly brushing and watering the surface to remove all dirts and remains of loose powdered material (A) For wall. 45 One Square Meter
43 31 Providing and fixing M.S. Grills of required pattern to wooden frames of windows etc. with MS flats at required spacing and frame around square or round bars with round headed bolts and nuts or by screw (A) plain grill 90 One Killo Gram
44 32 Point wiring for light / fan /bell / primary point with 2 - 1.5 sq mm & earth wire of 1.5 sq mm (green) both are of ISI marked FR PVC insulated multistrand copper wires, in existing pipe duly erected, complete with 6A Tissino Type ISI marked flush type switch/bel push and accessories erected on polished wooden block/metal, PVC box cover with 3mm thick laminated sheet for concealed wiring. (b) with 16 swg (1.6 mm thick) HGS metal conduit pipe and accessories painted black. Light Point (One Light Point controlled with one single way 6 A Switch), Light Point (One Light Point controlled with two single way 6 A Switch- Two way Light Point),Fan Point (One Fan Point controlled with one single way 6 A Switch) & Bell point 20 One Number
45 33 One 5 pin 5A 250 Volt Socket out let point controlled by 6 A switch on board 6 One Number
46 34 Providing Electronic hum free five steps EME fan regulator of modular type accessories mounted with PVC/Metallic box covered with appropriate front plate modules erected with necessary connection. Cat - III as desived by enginner in charge 1 One Number
47 35 Shockproof Tissino type single pole switch 6/16A universal plug socket as per wiring specification in Two Rooms 1.0 no. each 3 One Number
48 36 Providing Two pin /RJ -11 Telephone socket with top (Cat III) modular type accessories mounted with PVC / metallic box, single mounting base frame covered with textured/metallic front plate, modules erected with necessary connection as desired by engineer in charge. 1 One Number
49 37.01 Providing & laying Rigid PVC pipe confirming to I.S.S., erected with necessary fittings fixed with adhesive solution with 16 G. GI fish wire for concealed in wall / slab / Flooring with necessary cementation. Cabin & ESR 20 mm Size (3/4") 115 One Running Meter
50 37.02 25 mm Size (1") 40 One Running Meter
51 38 Supply and laying of main lines with ISI marked Copper conductor FRLS / ZHFR PVC insulated copper wire in existing pipe erected with earth continuity wire as specified in specification for following size. 2 wire 2.5 mm2 with mediam Class rigid PVC pipe 40 One Running Meter
52 39 Supplying and erecting approved make Telephone Cable electrolytic grade annealed copper conductor insulated with PE insulation twisted in to pairs with colour combination bunched together in concentric layers so as to minimal cross-talk & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for indoor telephone wiring & conforming to C-DOT S/WS113/IEC 60189-2, UL1581 section 1080 VW-1 erected with necessary connections. 2 Pair Telephone Cable 15 One Running Meter
53 40 Approved make Ceiling fan with condenser A.C. 50 Cys. 1400 mm. sweep complete, canopy and 30 cm. Down rod erected on existing hook or clamp with 24/0.2 flat 3 core flexible wire with earthing (or R.C. Rate) in Two Rooms 1.0 No. each make shall be approved by engineer in charge. 1 One Number
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.

Copyright © 2020 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail