Military Engineer Services-MES has published Repair/Maintenance Of Summer Appliances And Connected Items In The Area Of Age E/M Under Ge East Delhi Cantt-10. Submission Date for this Tender is 03-03-2020. Air Conditioner Tenders in GE (East) Delhi Cantt-10 Delhi. Bidders can get complete Tender details and download the document.
Name of Work : REPAIR/MAINTENANCE OF SUMMER APPLIANCES AND CONNECTED ITEMS IN THE AREA OF AGE E/M UNDER GE EAST DELHI CANTT-10 | |||||
---|---|---|---|---|---|
Sl. No. | Item Code / Make | Quantity | Units | ||
1 | 1 | Taking down old unserviceable point wiring from existing conduit / batten type (light, fan, socket or power point) such as switches, ceiling rose, pendent holder, regulator and socket etc and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing complete all as specified and as directed. | 190 | Per point | |
2 | 2 | Point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers including cutting in chases and FRLS PVC insulated unsheathed 1.5Sqmm copper conductor mulistranded earth wire, connecting to common earth dolly with and including metal flush box of suitable size for fixing switches/sockets etc complete all as specified and as directed for the following:-\n(Note : The cost of Metal boxes and cover plates etc shall be deemed to be included in quoted rate.)\n(a) One light point / fan point/ exhaust fan point / circulator fan point / bell/ buzzer controlled by one 1-way switch/ bell push | 90 | Per point | |
3 | 3 | (b) One socket outet point 5 amps on the same board. | 30 | Per point | |
4 | 4 | (c) One socket outet point 5 amps on the independent board. | 40 | Per point | |
5 | 5 | All as per description of Srl item No. 2 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for 15 Amp power point. | 30 | Per point | |
6 | 6 | Replacement of Switch piano flush type, single pole, one way, 5/6 Amps complete all as specified and as directed. | 500 | Each | |
7 | 7 | Replacement of socket two-in-one, 5 pin, 5/6 Amp universal type complete all as specified and as directed. | 500 | Each | |
8 | 8 | Replacement of switch 16 Amp,single pole one way complete all as specified and as directed. | 350 | Each | |
9 | 9 | Replacement of socket out let 6 pin, two-in-one type with 6 Amp & 16 Amp, flush type complete all as specified and as directed. | 350 | Each | |
10 | 10 | Replacement of submain wiring complete with 2 x 4.0 sqmm (nominal area) FRLS, PVC insulated, unsheathed and multistandard copper conductor cable ISI marked, and 1 x 2.5 sqmm as earth wire in and including PVC conduit of size 15 mm dia, medium grade and conduit fitting such as tees, bends, elbow, reducers etc. complete all as specified and as directed. | 900 | RM | |
11 | 11 | All as per description of srl item No. 10 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 4.0 Sqmm FRLS copper cable as earth wire, complete all as specified and as directed. | 600 | RM | |
12 | 12 | Replacement of Ventilating fan 250 mm sweep plastic body type including self closing louver and making all electric connections complete all as specified and as directed. | 150 | Each | |
13 | 13 | Replacement of Ventilating fan 200 mm sweep plastic body type including self closing louver and making all electric connectionscomplete all as specified and as directed. | 150 | Each | |
14 | 14 | Replacement of Exhaust fan 300mm sweep, single phase, DB, 240 volts, metallic body including suitable size self closing louver and making all electric connections complete all as specified and as directed. | 100 | Each | |
15 | 15 | Replacement of Pedestal fan 450 mm sweep (faratta type) metallic body including and making all electric connections complete all as specified and as directed. | 20 | Each | |
16 | 16 | Replacement of Wall mounted fan 400 mm sweep metallic body including and making all electric connections complete all as specified and as directed. | 50 | Each | |
17 | 17 | Replacement of Ceiling fan 1200mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase complete all as specified and directed. | 150 | Each | |
18 | 18 | Replacement of Ceiling fan 1400mm sweep, 240 V, DB, 5 star rating, 50 Hz, single phase complete all as specified and directed. | 100 | Each | |
19 | 19 | Desert cooler grass suitable for desert coolers of any size and type complete all as specified and as approved by Engr-in-Charge. | 20 | Each Set of Three | |
20 | 20 | Replacement of Desert cooler water pump, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed. Make : Havells/CG/Bajaj/Symphony.\n | 15 | Each | |
21 | 21 | Replacement of Desert cooler fan motor, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed. Make : Havells/CG/Bajaj/Symphony.\n | 15 | Each | |
22 | 22 | Replacement of Desert cooler regulator three steps type, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed. Make : Havells/CG/Bajaj/Symphony.\n | 15 | Each | |
23 | 23 | Replacement of Desert cooler fan blades, 240 volts, 50Hz suitable for desert coolers of any size and type, complete all as specified and as directed. Make : Havells/CG/Bajaj/Symphony.\n | 20 | Each Set of four Blades | |
24 | 24 | Taking down unserviceable ceiling fan any sweep from the site and refixing at the same site after greasing/oiling changing unserviceable bearing and capacitor and flexible wire of 23/0.0076 upto mtr length etc. complete all as specified and as directed. | 3800 | Each | |
25 | 25 | Replacement of electronic fan regulator piano type, in step and making all necessary connections complete all as specified and directed. | 800 | Each | |
26 | 26 | Replacement of electronic fan regulator socket type, in step and making all necessary connections complete all as specified and directed. | 500 | Each | |
27 | 27 | Replacement of Modular Fan regulator step type, 120 watts, 2 Module size complete all as specified and directed. | 100 | Each | |
28 | 28 | Replacement of motor with PVC blades suitable for any type fresh air fan with copper wound motor, complete all as specified and as directed. Make : Havells/CG/Usha. | 400 | Each | |
29 | 29 | Replacement of motor with GI blade suitable for 225mm sweep exhaust fan with copper wound motor, complete all as specified and directed. Make : Havells/CG/Usha. | 70 | Each | |
30 | 30 | Rewinding of exhaust fan/Fresh air fan of any size and make (225mm to 300mm sweep) with super enamelled copper winding wire of required size duly varnishing including greasing/oiling, commissioning and testing to the entire satisfaction of Engr-in-Charge. | 800 | Each | |
31 | 31 | All as per description of Srl item No. 30 here-in-before but 375mm sweep. | 200 | Each | |
32 | 32 | All as per description of Srl item No. 30 here-in-before but 450mm sweep. | 50 | Each | |
33 | 33 | Replacement of plastic body capacitor of cap 2.5 mfd with wire suitable for single phase motor and making connection complete all as directed. Make : Surya/Usha/TIBCON/Havells | 2500 | Each | |
34 | 34 | All as per description of Srl item No. 33 here-in-before but of 3.15 mfd capacity. | 400 | Each | |
35 | 35 | All as per description of Srl item No. 33 here-in-before but of 4.0 mfd capacity. | 50 | Each | |
36 | 36 | Replacement of steel clamps of fan rod including bolts, nuts, washers and split pin etc., suitable for 1200/1400mm sweep fan, complete all as specified and as directed. | 500 | Each | |
37 | 37 | Replacement of PVC canopy of fan rod suitable of 1200/1400mm sweep fan, complete all as specified and as directed. | 200 | Each | |
38 | 38 | Replacement of twin twisted flexible, PVC insulated, unsheathed, multistranded copper conductor wire of size 24x0.0076, complete all as specified and as directed. | 900 | RM | |
39 | 39 | Rewinding of ceiling fan old/new model any size, 1200mm sweep with super enamelled copper wire of required size as per existing gauge & pattern & varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engr-in-Charge, complete all as specified & as directed. | 1800 | Each | |
40 | 40 | Rewinding of ceiling fan old/new model any size, 1400mm sweep with super enamelled copper wire of required size as per existing gauge & pattern &varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engr-in-Charge, complete all as specified & as directed. | 1500 | Each | |
41 | 41 | Rewinding of wall mounting fan of any size and sweep with super enamelled copper wire of required size duly varnishing including greasing/oiling and commissioning/testing to the entire satisfaction of Engr-in-Charge. | 100 | Each | |
42 | 42 | Supply only ball bearing No 6201 suitable for ceiling fan. Make Usha/NBC/SKF. | 1500 | Each | |
43 | 43 | Supply only ball bearing No 6202 suitable for ceiling fan. Make Usha/NBC/SKF. | 1500 | Each | |
44 | 44 | LT underground cable XLPE insulated, PVC sheathed, galvanised steel strip / wire armoured, aluminium conductor, 1100 volts grade, of size 16 Sqmm 2 core suitable for earthed system laid in duct / trench / along pole / wall etc including making connection, complete all as specified and as directed. \n(Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.\n2. The excavation, earth work, sand cushioning and brick protection etc will be measured and paid separately under respective items.) | 200 | RM | |
45 | 45 | Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides, complete all as specified and as directed. | 36.45 | Cum | |
46 | 46 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick, complete all as specified and as directed. | 16.9 | Cum | |
47 | 47 | Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point, complete all as specified and as directed. | 19.55 | Cum | |
48 | 48 | Mechanical protection to cable using old size sub class 'B' bricks, laid flat, dry, butt jointed, laid length wise perpendicular to the axis of cable, complete all as specified and as directed. | 1560 | Each | |
49 | 49 | Sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable, complete all as specified and as directed. | 14.6 | Cum | |
50 | 50 | Replacement of PVC enclosure, SPN type with two pin & earth plug and socket (Industrial type DB) with and including one MCB SP, C Curve type of capacity 32 Amp, 10 kA, complete all as specified and as directed. | 50 | Each | |
51 | 51 | Replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and as directed. | 50 | Each | |
52 | 52 | Replacement of MCB C Curve type, 10 kA, 40 to 63 Amp, Single Pole with and neutral over load and short circuit protection, complete all as specified and as directed. | 20 | Each | |
53 | 53 | Replacement of switch socket combination 2 in 1, 5 pin type 6 Amp, flush typecomplete all as specified and as directed. | 50 | Each | |
54 | 54 | Replacement of plug top 3 pin 6 amp, 240 volts, complete all as specified and as directed. | 300 | Each | |
55 | 55 | Replacement of plug top 5 pin 16 amp, 240 volts, complete all as specified and as directed. | 300 | Each | |
56 | 56 | Replacement of PVC box 2 Way for fixing switch socket, 240 volts, complete all as specified and as directed. | 100 | Each | |
57 | 57 | Replacement of PVC box 4 Way for fixing switch socket, 240 volts, complete all as specified and as directed. | 100 | Each | |
58 | 58 | Replacement of Isolator 63 Amp, Triple Pole with and neutral, 415 volts, complete all as specified and as directed. | 50 | Each | |
59 | 59 | Replacement of Low/High voltage cut off switch, complete all as specified and as directed. | 10 | Each | |
60 | 60 | Replacement of brass bush suitable size for 3 to 5KVA automatic voltage stabilizer, complete all as specified and as directed by Engr-In-Charge. | 20 | Each | |
61 | 61 | Replacement of copper thimbles of suitable for 3 to 5KVA automatic voltage stabilizer, complete all as specified and as directed by Engr-In-Chage. | 40 | Each | |
62 | 62 | Galvanized iron pipe of 15 mm bore medium grade for making down rod for hanging of ceiling fans, including mild steel clamp of suitable size and shape, complete all as specified and as directed by Engr-In-charge.\n(Note : The cost of MS clamp, nut, bolt, washers, rubber reel etc shall be inclusive in the item rate.) | 100 | RM | |
63 | 63 | Taking down Window/Split Type Air Conditioner of any make, size of 1.5/2 Ton capacity from existing site including provisioning of dismantling all electrical items/connected parts such as relay capacitor, compressors grills etc and spray cleaning by means of electric air blower and water descaling by using acid on both side of cooling coil and condenser cleaning with nylon brush and washing with clean water to ensure proper cleaning before reassembling complete unit and refixing at site including testing and commissioning complete all as specified & directed at site to the entire satisfaction of GE. Note :- (a) Parts found defective after dismantling of ACs requiring replacement will be measured and paid separately under relevant items described here in after however refilling of refrigerant gas and other parts required for dismantling/reassembling of the ACs will be deemed to be included in the quoted rate. | 22 | Each | |
64 | 64 | Replacement of rotary type compressor for window type AC cap 1.5 TR Make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant complete all as specified & directed. Make : LG/Voltas / Carrier. | 4 | Each | |
65 | 65 | Replacement of rotary type compressor for Split AC cap 1.5 TR Make- and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant complete all as specified & directed. MAKE : LG/Voltas / Carrier. | 4 | Each | |
66 | 66 | Replacement of rotary type compressor for Split AC cap 2 TR make and type as per existing compressor making suction pipe and discharge pipe connections with copper welding/brazing making it leak proof. Pressure testing vacuuming and charging of refrigerant complete all as specified & directed. Make : LG/Voltas / Carrier. | 4 | Each | |
67 | 67 | Replacement of starting relay SR-1622 complete all as specified and as directed Make- RENUTRAL / GODREJ / WHIRLPOOL. | 10 | Each | |
68 | 68 | Replacement of starting relay 3 or 4 terminal with connecting leads suitable for any type and make of window air conditioner of 1.5 Ton capacity complete all as specified & directed. MAKE : RENUTRAL / GODREJ / WHIRLPOOL/LG/VOLTAS. | 5 | Each | |
69 | 69 | Replacement of 1.5 TR window type AC Kit having (a) Condenser (b) evaporator (c) Condenser motor with blower but without compressor complete all as specified & directed. MAKE : RENUTRAL / GODREJ / WHIRLPOOL/LG/VOLTAS. | 5 | Each | |
70 | 70 | Rectification of leakage in window type/Split AC’s cap 1.5/2 TR by pressure testing making it leak proof by copper welding/brazing vacuming and charging of refrigerant R-22 complete all as specified & directed. | 12 | Each | |
71 | 71 | Replacement of front grill suitable for any type and make of window air conditioner 1.5 T R capacity having good aesthetic look good quality as per sample/at site of any make/model approved by GE complete all as specified & directed. Make : LG/Voltas | 8 | Each | |
72 | 72 | Outdoor unit for split type AC 1.5 TR complete with compressor condenser coil condenser Motor fan etc complete all as specified & directed. Make-LG/Voltas/Blue Star. | 4 | Each | |
73 | 73 | Replacement of double shaft fan motor 1/5 HP Make and type as per existing motor complete all as specified & directed. | 6 | Each | |
74 | 74 | Replacement of capacitor Running Cap 36 to 45 Mfd suitable for operating voltage 240 Volt, 50 HZ complete all as specified & directed. Make:USHA / GODREJ / UNIVERSAL /L&T | 10 | Each | |
75 | 75 | Replacement of capacitor Running Cap 55-60 Mfd suitable for operating voltage 240 Volt, 50 HZ complete all as specified & directed. Make: USHA / GODREJ / UNIVERSAL /L&T | 5 | Each | |
76 | 76 | Replacement of starting capacitor 80-100 Mfd complete all as specified & directed. Make: USHA / GODREJ / UNIVERSAL /L&T | 4 | Each | |
77 | 77 | Replacement of starting capacitor 100-120 Mfd complete all as specified & directed. Make; USHA / GODREJ / UNIVERSAL /L&T | 4 | Each | |
78 | 78 | Replacement of air filter element for 1.5 ton window type air conditioner of any make and type as per sample complete all as specified & directed. | 10 | Each | |
79 | 79 | Replacement of thermostat suitable for any type and make of window Air conditioner 1.5 ton capacity complete all as specified & directed. MAKE : GODREJ / RENUTROL / WHIRLPOOL | 10 | Each | |
80 | 80 | Replacement of blower motor 0.5 HP with blower blade assembly complete in all respect for operating voltage 240 volts, 50 HZ and for any type or make of window air conditioner of 1.5/2 ton capacity complete all as specified & directed. Make : GODREJ / BAJAJ | 5 | Each | |
81 | 81 | Replacement of swing motor complete in all respect for operating voltage 240 volts 50 HZ and for any type and Make of window /Split type air conditioner of 1.5/2 Ton capacity complete all as specified & directed. Make : GODREJ /VIDEOCON /CARRIER | 8 | Each | |
82 | 82 | Replacement of blower of blower motor for split type AC 1.5 /2 TR Make and type as per existing motor complete all as specified & directed | 7 | Each | |
83 | 83 | Replacement of blower motor capacitor 6 mfd suitable for operating voltage 240 volt, 50 HZ complete all as specified & directed. MAKE : USHA / GODREJ / UNIVERSAL /L&T | 15 | Each | |
84 | 84 | Replacement of gun metal bush suitable for blower motor of any type and make of window type AC of 1.5/2 Ton capacity complete all as specified and as directed. | 8 | Each | |
85 | 85 | Taking out unserviceable window /Split type air conditioner of any type, make and capacity after opening the electrical connections, preparing the compressor for refilling and recharging the compressor and M&L for refilling the compressor oil in adequate quantity and recharging the R-22 gas in adequate quantity and refixing the complete component of A/C including refixing the window /Split type A/C at its location and testing for effective cooling can be achieved complete all as specified and as directed. | 25 | Each Job | |
86 | 86 | Replacement of rewinding for blower fan motor of window / Split type AC 1.5 TR capacity with proper gauge super enammelled of copper wire not less than 300 gm/unit including testing etc complete all as specified and as directed. | 4 | Each Job | |
87 | 87 | Scrubbing down of old paint from 1.5/2 ton capacity window / Split type AC with emary paper, cleaning washing, filling cavities, welding, soldering, denting etc and M&L for spray painting to AC unit with two coats synthetic enamel white paint and after drying writing MES No complete all as specified and as directed. | 5 | Each Job | |
88 | 88 | Disconnecting electrical connection and taking down/removing unserviceable single phase voltage stabilizer 4 KVA or 5 KVA capacity of any make and transporting same to MES Yard for annual repair /servicing /cleaning /maintenance. Dismantling the stabilizer segregating unserviceable/wornout parts, carryout repair including replacement of worn out parts, rewinding burnt out transformer as per existing reassembling all components and transporting the same upto its original location, fitting/fixing and testing for effective working complete all as specified and as directed. Note: New spares shall be measured and paid as supply only here-in-after separately. However spare not mentioned in this schedule and required for smooth functioning of stabilizers are deemed to be included in the quoted rate under this item. | 15 | Each Job | |
89 | 89 | Replacement of cut off relay for any type of make voltage stabilizer 4/5 KVA of any type and make complete all as specified and as directed. MAKE : AE / VINTEC / BRENTFORD | 10 | Each | |
90 | 90 | Replacement of electronic (PCB) for circuit plate for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type complete all as specified and as directed. MAKE : AE/VINTEC/BRENTFORD | 12 | Each | |
91 | 91 | Volt meter for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type complete all as specified and as directed. MAKE : AE / MECO | 10 | Each | |
92 | 92 | Fuse grip for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type complete all as specified and as directed. MAKE : AE / VINTEC / BRENTFORD | 10 | Each | |
93 | 93 | Control transformer for voltage stabilizer 4 KVA or 5 KVA capacity of any make and type complete all as specified and as directed. Make : AE / VINTEC / BRENTFORD | 10 | Each | |
94 | 94 | Voltage stablizer 4KVA Capacity, 240 Volts, 50 HZ, including making electric connection with copper wire PVC insulated of suitable size, complete all as specified and as directed. Make : VINTEC/ Brentford/Kirloskar. | 5 | Each | |
95 | 95 | High pressure monoblock pump with 24 ltr capacity pressure tank, coupled with electric motor of capacity 0.50 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe complete all as specified and as directed. Make: Lubi/CG/V Guard/Khaitan/CR/Leader | 15 | Each | |
96 | 96 | High pressure booster pump with 24 ltr capacity pressure tank, coupled with electric motor of capacity 0.93 HP, 230 volts, single phase, 50 Hz incl connecting accessories of GI i.e bend, nipple, socket, tee of requisite size etc incl cutting of existing pipe complete all as specified and as directed. Make: Lubi/CG/V Guard/Khaitan/CR/Leader | 15 | Each | |
97 | 97 | Earthing complete with GI earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation, complete all as specified and as directed. | 20 | Each Job | |
98 | 98 | NOTE :- For minimum fair wages ,EPF and payment to labour employed, refer Sch A Note No-16,17 and Special Condition 22 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record. \n |