| 1 | 10 | ARC for Electrical Testing Jobs | Item 00010 | | |
|---|
| 2 | 10.01 | LAYING OF LT POWER/ CONTROL/ TELEPHONE/ INSTRUMENT/ CCTV/ COMPUTER AND OTHER CABLES ON CABLE TRAYS/ STRUCTURES Horizontal and vertical laying of one or more armoured / unarmoured PILCA / PVC insulated and PVC sheathed / XLPE LT power (voltage grade upto 1.1 KV)/ control/ telephone/ instrument/ CCTV/ computer and other cables on cable racks/ wall and steel structures upto any height, fixing of saddles, aluminium strip, number tags ( if required), testing plus transportation from stores to site, unpacking, straightening, dressing of cable, fixing with clams/ cleats as required and returning the empty drum with unused cable, if any, to stores etc. all complete with labour and materials as per the drawings, specifications and directions of the Engineer-in-charge. NOTE: Cables will be supplied by the Owner free of cost. | Item 10.10 | | |
|---|
| 3 | 10.02 | Overall diameter upto 35 MM | Item 10.20 | 5000 | M |
|---|
| 4 | 10.03 | Overall diameter > 35 MM but upto 55 MM | Item 10.30 | 5000 | M |
|---|
| 5 | 10.04 | DRESSIING OF CABLES Dressing of cable in underground trenches, cable trays/rack etc. including supply and fixing of clamps etc., wherever necessary, as per the direction of the Engineer-in-charge | Item 10.40 | | |
|---|
| 6 | 10.05 | Overall diameter upto 35 MM | Item 10.50 | 10000 | M |
|---|
| 7 | 10.06 | Overall diameter > 35 MM but upto 55 MM | Item 10.60 | 3000 | M |
|---|
| 8 | 10.07 | EXCAVATION OF EARTH FOR CABLE / PIPE LAYING FOR ELECTRICAL WORK Excavation of earth for cable trenches / laying of G.I. pipes for cable work in all types of soils including saturated soil upto a max. depth of 1.5 metres including shoring, strutting and bailing out of water (if necessary), backfilling and compacting in layers not exceeding 20 cm. thick to the finished ground level and disposal and dressing of excess earth within a lead of 50 metres all complete with labour and materials as per standards, drawings, specifications and directions of Engineer-in-charge. | Item 10.70 | 50 | M3 |
|---|
| 9 | 10.08 | SUPPLYING AND FIXING OF GI ROUTE MARKER Suppplying cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription thereon, bolted/ welded to 35 mm x 35 mm x 6 mm angle iron, 60cm long and fixing the same in ground as required. Job includes painting with one coat of redoxide and finishing paint. | Item 10.80 | 100 | EA |
|---|
| 10 | 10.09 | EXTRA FOR PROVIDING COPPER LUGS Supply of copper tube terminal heavy duty (crimping cable lug) of KSE / Dowells make or equivalent certified by EIC. of the following sizes. | Item 10.90 | | |
|---|
| 11 | 10.1 | 1.5 sqmm | Item 10.100 | 1000 | EA |
|---|
| 12 | 10.11 | 2.5 sqmm | Item 10.110 | 1000 | EA |
|---|
| 13 | 10.12 | EXTRA FOR PROVIDING SINGLE COMPRESSION (BRASS) CABLE GLANDS Supply of single compression (brass) heavy duty type cable gland for following over all cable sizes as per directions of Engineer-in-Charge. | Item 10.120 | | |
|---|
| 14 | 10.13 | 19MM | Item 10.130 | 25 | EA |
|---|
| 15 | 10.14 | 32 mm | Item 10.140 | 25 | EA |
|---|
| 16 | 10.15 | 22 mm | Item 10.150 | 25 | EA |
|---|
| 17 | 10.16 | 63 AMPS. DISTRIBUTION TAP OFF BOX Supplying, installing, testing and commissioning of distribution tap off box of following capacity on existing rising mains and complete with HRC fuse links and interconnections, earthing etc. as required. | Item 10.160 | | |
|---|
| 18 | 10.17 | 63 A TPN 4 way | Item 10.170 | 5 | EA |
|---|
| 19 | 10.18 | 100 AMPS. DISTRIBUTION TAP OFF BOX Supplying, installing, testing and commissioning of distribution tap off box of following capacity on existing rising mains and complete with HRC fuse links and interconnections, earthing etc. as required. | Item 10.180 | | |
|---|
| 20 | 10.19 | 100 A TPN 4 way | Item 10.190 | 5 | EA |
|---|
| 21 | 10.2 | MCB CONSUMER UNIT WITH IP 54 PROTECTION Supplying and fixing of following way, prewired single pole and neutral sheet steel MCB consumer unit, 240 volts, on surface / recess complete with tinned copper busbar, neutral link, earth bar, din bar, hinged front accrylic cover for the MCB knobs, detachable gland plate, inter connections including painting, earthing etc. as required (with IP 54 protection). | Item 10.200 | | |
|---|
| 22 | 10.21 | 2+4 Way | Item 10.210 | 5 | EA |
|---|
| 23 | 10.22 | SUPPLY & INSTLN. OF FUSE PARTS Supply, fixing and connection of following KNIFE TYPE HRC fuse link AS PER IS:13703:1993 & IEC 269:1986 of M/S HAVELL/L&T /G EC Astholm/Standard /MDS make or approved equivalent in distribution board etc.all complete with labour and materials as per direction of Engineer-in-charge. KNIFE TYPE HRC FUSE LINK | Item 10.220 | | |
|---|
| 24 | 10.23 | 500, 630 AMP ( HCD03 series) BOLTED TYPE HRC FUSE LINK | Item 10.230 | 40 | EA |
|---|
| 25 | 10.24 | 400-500 AMP ( HTTM series) | Item 10.240 | 40 | EA |
|---|
| 26 | 10.25 | SHIFTING OF PANEL/ MOTOR/ EQUIPMENT Transportation from the store to the site or from worksite to worksite within battery area or within township of panel, motor and any other equipment alongwith all necessory accessories without any damage. All complete with labour, materials, necessary tools/ tackles and shifting vehical/ mode as per the direction of Engineer-in-Charge. | Item 10.250 | | |
|---|
| 27 | 10.26 | Equipment weighing above 500 kg & upto 3MT and requiring hydra and tractor trolley etc. | Item 10.260 | 5 | EA |
|---|
| 28 | 10.27 | SUPPLY AND FIXING OF EQUIPMENT IN PANELS Supply, fixing and connection of following equipments in panels including small mechanical works and supply of all fixing materials. All complete with labour and materials as per the direction of Engineer-in-Charge | Item 10.270 | | |
|---|
| 29 | 10.28 | Control contactors- 4 contacts for DC control standard coil voltage - 24, 110, 220 Type MM00 of L&T or equivalent | Item 10.280 | 50 | EA |
|---|
| 30 | 10.29 | Control contactors- 4 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MM00 of L&T equivalent | Item 10.290 | 50 | EA |
|---|
| 31 | 10.3 | Control contactors- 8 contacts for AC control standard coil voltage - 25, 110, 240, 415, 50Hz Type MM01 of L&T equivalent | Item 10.300 | 50 | EA |
|---|
| 32 | 10.31 | Thermal Relays type MN2 with single phasing protection - 0.2 - 0.33 A to 14 -23A (Direct operated) | Item 10.310 | 50 | EA |
|---|
| 33 | 10.32 | Thermal Relays type MN5 with single phasing protection - 20-33 TO 30.0 - 50.0 A (Direct operated) | Item 10.320 | 50 | EA |
|---|
| 34 | 10.33 | Thermal Relays type MN5 with single phasing protection - 45-75 TO 66-110 A (Direct operated) with separate mounting | Item 10.330 | 50 | EA |
|---|
| 35 | 10.34 | Thermal Relays type MN12L with single phasing protection - 42 - 69 A to 180 - 300 A (CT operated) with separate mounting | Item 10.340 | 50 | EA |
|---|
| 36 | 10.35 | Thermal Relays type ML0/ML1/ML1.5 - 0.15 - 0.25 A to 10.0 - 16.0 A (Direct operated) contractor | Item 10.350 | 50 | EA |
|---|
| 37 | 10.36 | Thermal Relays type ML2/ML3 - 9.0 - 14.0 A to 28.0 - 42.0 A (Direct operated) contractor | Item 10.360 | 50 | EA |
|---|
| 38 | 10.37 | Automatic AC ammeter (Automatic Electric make or approved equivalent) 96 mm x 96 mm square type block backalite case/flush mounting/moving iron/spring controlled suppressed scale, CT operated AC ammeter/range 0-300-1800 A, CT ratio 300/IA/ accuracy +/-2.5%. | Item 10.370 | 50 | EA |
|---|
| 39 | 10.38 | Automatic AC Volt meter (Automatic Electric make or approved equivalent) 96 mm x 96 mm square type block backalite case/flush mounting AC Volt meter/range 0-600 accuracy +/-2.5%. | Item 10.380 | 50 | EA |
|---|
| 40 | 10.39 | Installation of Current Transformer of any rating | Item 10.390 | 100 | EA |
|---|
| 41 | 10.4 | FIXING OF ELECTRICAL COMPONENTS Fixing, fitting, commissioning, assembly of loose supplied components, if any, and connecting of one no. switch fuse unit / automate / starter of rating upto 400 A , 3 phase , 415 V with on distribution Panel or in control panel, mounted on wall / floor etc. transportation of automate / starter / switch fuse unit from the store to the site (maximum distance of 10 KM ) . Job complete in all respect with labour and as per the drawing and direction of Engineer-in-charge excluding supply of switch fuse unit / automate / starter. | Item 10.400 | 500 | EA |
|---|
| 42 | 10.41 | REMOVING & REPLACING OF CHEQUERED PLATE Removing of MS chequered plate for cable ducks/ trenches and placing them after the job as per directions of EIC. | Item 10.410 | 500 | EA |
|---|
| 43 | 10.42 | LT PANEL CLEANING Cleaning of complete PCC/MCC panels. It includes opening of side top covers, removal of dust by vacuum cleaners/blowers etc., checking and tightening of screws, nuts, bolts, washers & connections, application of petroleum jelly and boxing up of the panels. All complete with labour and materials as per directions of the Engineer-in-Charge. | Item 10.420 | 200 | EA |
|---|
| 44 | 10.43 | LAYING OF RUBBER MATS Laying of 12 mm or above thick rubber floor mats suitable for working on equipment upto 33 KV working voltage incl. Cutting the rubber mats to shape and size as required. Job complete in all respect with labour and transportation from store to site and as per directions of Engineer-in-charge, excluding the supply of rubber floor mats. | Item 10.430 | 100 | M2 |
|---|
| 45 | 10.44 | PAINTING OF ELECTRICAL EQUIPMENTS Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of enamel paint by spray painting on bus ducts, transformers/motors or any other metallic surface with one coat of ready mixed primer and two coats of approved quality/APCOLITE ASIAN synthetic enamel paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and materials as per directions of the Engineer-in-Charge. | Item 10.440 | 300 | M2 |
|---|
| 46 | 10.45 | Lettering with black Japan paint of approved brand and manufacture Note : Unit of measurement is considered EACH which is equal to per cm height per letter. | Item 10.450 | 1000 | EA |
|---|