Construction Of Rcc Duplex Type Inspection Bunglow At Bihpuria Lac Under Sopd ( G ) For 2019-20
Tender Value
1.35 Crore
Estimated cost
Bid Submission
17 Feb 2020
0 days left
EMD
2.71 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bihpuria → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction of Rcc Duplex Type Inspection Bunglow At Bihpuria Lac Under Sopd ( G ) For 2019-20
BOQ
| Name of Work: Constructionof RCC Duplex Type Inspection Bunglow at Bihpuria LAC under SOPD(G) for 2019-20 | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | BI01010001010000000000000515BI0100001113 | 285 | Cu.m |
| 2 | 2 | Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered)\n(b) Above 1.5 m upto 3.00 m depth | BI01010001010000000000000515BI0100001114 | 203.26 | Cu.m |
| 3 | 3 | Supplying and filling sand gravel in foundation trenches of column footings over slushy soil including local carriage of materials within 8 km pumping out of water, ramming etc. complete for strengthening the bearing capacity of the soil as directed and specified including payment of Forest Royalty and Sales Tax and other duties and taxes as may be necessary. | BI01010001010000000000000515BI0100001115 | 55.21 | Cu.m |
| 4 | 4 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. | BI01010001010000000000000515BI0100001116 | 148.77 | Cum |
| 5 | 5 | Raising low site around the building with approved soil obtained from outside by truck \ncarriage including breaking clods, dressing etc. complete including paying necessary\n forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty\n etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made\n from total quantity) etc. complete as directed and specified. | BI01010001010000000000000515BI0100001117 | 368.26 | cum |
| 6 | 6 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volume | BI01010001010000000000000515BI0100001118 | 27.64 | Cum |
| 7 | 7 | Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete. \nc) 100mm thick | BI01010001010000000000000515BI0100001119 | 198.36 | Sqm |
| 8 | 8 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | BI01010001010000000000000515BI0100001120 | 32.72 | Sqm |
| 9 | 9 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nP) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nb) M20 grade concrete or Prop. 1:1.5:3 | BI01010001010000000000000515BI0100001121 | 57.4 | Cum |
| 10 | 10 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(B) In super structure from plinth level up to 1st floor level. \nii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nP) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nb) M20 grade concrete or Prop. 1:1.5:3 | BI01010001010000000000000515BI0100001122 | 107.3 | Cum |
| 11 | 11 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(B) In super structure from plinth level up to 1st floor level. \nii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nP) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nb) M20 grade concrete or Prop. 1:1.5:3\nExtra over above item, above for each subsequent floor or part thereof above the 1st floor level. | BI01010001010000000000000515BI0100001123 | 36.53 | Cum |
| 12 | 12 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\nii) Using 25mm thick plank | BI01010001010000000000000515BI0100001124 | 90.1 | Sqm |
| 13 | 13 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face | BI01010001010000000000000515BI0100001125 | 141.12 | Sqm |
| 14 | 14 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nSides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\na) For depth not exceeding 1.0M. | BI01010001010000000000000515BI0100001126 | 331.51 | Sqm |
| 15 | 15 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nFlat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness. | BI01010001010000000000000515BI0100001127 | 368.92 | Sqm |
| 16 | 16 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nStaircase with sloping or stepped soffits including risers and stringers but excluding Landing. | BI01010001010000000000000515BI0100001128 | 15.3 | Sqm |
| 17 | 17 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nExtra for each subsequent floor or part thereof above the First Floor level for shuttering | BI01010001010000000000000515BI0100001129 | 386.08 | Sqm |
| 18 | 18 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\na) Brick on flat Solling | BI01010001010000000000000515BI0100001130 | 197.2 | Sq.m |
| 19 | 19 | Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level.\nb) In prop 1:4 | BI01010001010000000000000515BI0100001131 | 19.66 | Cum |
| 20 | 20 | 112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(a). In cement mortar in proportion 1:4.(1 cement:4 sand) | BI01010001010000000000000515BI0100001132 | 516.15 | Sqm |
| 21 | 21 | Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\nb) Executive range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make\ni) Of size 800mmx800mm and above | BI01010001010000000000000515BI0100001133 | 318.89 | Sqm |
| 22 | 22 | Providing polished vitrified wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/white cement slurry mixed with approved pigment to match shade of tilesc complete at all levels as specified and directed. (coloured pigment should be in conformity with colour of tiles and as approved and directed by the department).\ni) Of size 300mmx450mm and above | BI01010001010000000000000515BI0100001134 | 120 | Sqm |
| 23 | 23 | 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels.\n(i) Dungri slab | BI01010001010000000000000515BI0100001135 | 105.21 | Sqm |
| 24 | 24 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\n(b). In cement mortar 1:4 | BI01010001010000000000000515BI0100001136 | 384.12 | Sqm |
| 25 | 25 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side\n(b). In cement mortar 1:4 | BI01010001010000000000000515BI0100001137 | 426.83 | Sqm |
| 26 | 26 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\n(b). In cement mortar 1:4 | BI01010001010000000000000515BI0100001138 | 461.57 | Sqm |
| 27 | 27 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\n(b). In cement mortar 1:4\nExtra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. | BI01010001010000000000000515BI0100001139 | 384.12 | Sqm |
| 28 | 28 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\n(b). In cement mortar 1:4\nExtra over item no 6.2.1 to 6.2.3 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed.\nb) On two coat plaster | BI01010001010000000000000515BI0100001140 | 461.57 | Sqm |
| 29 | 29 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. \n(a) With sal wood\n | BI01010001010000000000000515BI0100001141 | 1.36 | Cu.m |
| 30 | 30 | Providing, fitting and fixing factory made wooden panelled doors with panel inserts of 75mm to 50mm width and 12mm to 20mm thickness,joined together with continous tongue and groove joints glued together with Movicol or other approved adhesive leaving a vertical groove of 7.5mm to 15mm between the inserts,the edges of panel inserts being feather tongue into styles and rails including providing three pairs of oxidised M.S butt hinges (100mm x75 mm x3.55mm) and furnishing with moulded timber beading of size 25mmx15mm around the panels complete as per drawing (moulded timber bead and all fittings except hinges to be paid separately) \na) With Teak wood / Sissu wood.\n(i) 40 mm thick with panel inserts of 20mm thickness.\n | BI01010001010000000000000515BI0100001142 | 50.72 | Sq.m |
| 31 | 31 | Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. \n | BI01010001010000000000000515BI0100001143 | 188.68 | Sqm |
| 32 | 32 | Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) (Dyna roof / Sathyam/ Durakolor/ Century Wells) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) \n(iv) 0.60 mm thick | BI01010001010000000000000515BI0100001144 | 301.34 | Sqm |
| 33 | 33 | Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) (Dyna roof /Sathyam/ Durakolor/Century Wells) at all levels including fitting and fixing self drilling, self tapping screws complete complete.\n(iv) 0.60 mm thick | BI01010001010000000000000515BI0100001145 | 38.6 | R.m |
| 34 | 34 | Providing, fitting and fixing M.S. grill of requiredpattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nII Ornamental grill\n(c). Fixed to Brickwork/P.C.C/R.C.C. \n | BI01010001010000000000000515BI0100001146 | 740 | Kg |
| 35 | 35 | Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(b)3 Track sliding window\n(i)6mm clear glass | BI01010001010000000000000515BI0100001147 | 66 | Sq.m |
| 36 | 36 | Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed. | BI01010001010000000000000515BI0100001148 | 810.95 | Sqm |
| 37 | 37 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick | BI01010001010000000000000515BI0100001149 | 461.57 | Sqm |
| 38 | 38 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | BI01010001010000000000000515BI0100001150 | 810.95 | Sqm |
| 39 | 39 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | BI01010001010000000000000515BI0100001151 | 810.95 | Sqm |
| 40 | 40 | Applying one self-priming coat of acrylic emulsion coating of Unicem \"Rakshak\" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. | BI01010001010000000000000515BI0100001152 | 461.57 | Sqm |
| 41 | 41 | Supplying and applying interior/exterior walls/ floors/ roofs one coat of Epoxy Primer of Jenson & Nicholson/ Nerolac brand as priming coat after cleaning and clearing the surfaces as specified and directed and then applying two coats of Epoxy paints of Jenson & Nicholson/ Nerolac brand of required shade on walls/ floors/ roof surfaces as specified and directed complete including scaffolding at all levels. | BI01010001010000000000000515BI0100001153 | 461.57 | Sqm |
| 42 | 42 | Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white). \n | BI01010001010000000000000515BI0100001154 | 88.2 | Sq.m |
| 43 | 43 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer. | BI01010001010000000000000515BI0100001155 | 132 | Sqm |
| 44 | 44 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | BI01010001010000000000000515BI0100001156 | 132 | Sqm |
| 45 | 45 | Varnishing two coats (excluding priming coat) on new wood and wood based surfaces under coating with flatting varnish and finishing coat with copal varnish or spar varnish to give an even surface including cleaning the surface of all dirt,dust and filling the knots,crack etc with specially made wood putty and sand papering so as to produce a smooth,dry and matt surface.\n(i) Surfaces over 100mm in width or girth.\n | BI01010001010000000000000515BI0100001157 | 88.2 | Sq.m |
| 46 | 46 | Polishing with french sprit polishing on new wood and wood based surfaces to give an even surface including cleaning the surface of all dirt, dust sand papered smooth and including a coat of wood filter \n | BI01010001010000000000000515BI0100001158 | 88.2 | Sq.m |
| 47 | 47 | Applying two coats of wood preservative oil,colourless (Burger Products) on new wood and wood based surfaces, after including preparing the surface by throughly cleaning oil,grease,dirt and other foreign matter, sand papering and knotting. \n | BI01010001010000000000000515BI0100001159 | 88.2 | Sq.m |
| 48 | 48 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\na) Sliding door bolts, i) 300mm x 16mm | BI01010001010000000000000515BI0100001160 | 16 | Each |
| 49 | 49 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\nb) Tower bolts, i) 300mm x 10mm | BI01010001010000000000000515BI0100001161 | 30 | Each |
| 50 | 50 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\nc) Door handles, iii) 150mm | BI01010001010000000000000515BI0100001162 | 16 | Each |
| 51 | 51 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\ne) Butt hinge, i) 125mm x 50mm x 4mm | BI01010001010000000000000515BI0100001163 | 44 | Pair |
| 52 | 52 | Supplying, fitting, fixing brass fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary c.p. brass screws etc. complete.( bright natural matt & satin finished ).\no) Mortice cylindrical type(Godrej make)-polished Brass | BI01010001010000000000000515BI0100001164 | 8 | Each |
| 53 | 53 | Providing,fitting and fixing Door closer of various type UL listed and fire rated good quality depending on the door specification.Types like single speed,Double Speed,Heavy Duty etc are available and as directed & specified by the department.\nA) Godrej\ne) Concealed Door Closer ( 230mm x 76.5mm x 30.5mm) | BI01010001010000000000000515BI0100001165 | 8 | Each |
| 54 | 54 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement bar | BI01010001010000000000000515BI0100001166 | 177.32 | Qtt |
| 55 | 55 | Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. \na) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997\n | BI01010001010000000000000515BI0100001167 | 42.55 | Qtl. |
| 56 | 56 | Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish. | BI01010001010000000000000515BI0100001168 | 62.4 | Sq.m |
| 57 | 57 | Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\nii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm. | BI01010001010000000000000515BI0100001169 | 62.4 | R.m |
| 58 | 58 | Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution. | BI01010001010000000000000515BI0100001170 | 234.36 | Sqm |
| 59 | 59 | Any other Item of work not covered in the estimate as per SOR 2013-14 | BI01010001010000000000000515BI0100001171 | 1 | Unit |
| 60 | 60 | Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) \nBRAND : FIRESTOP / FIREND / FIRE SHIELD | BI01010001010000000000000515BI0100001172 | 8 | Each |
| 61 | 61 | BOUNDARY WALL AND GATE\nEarthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soil | BI01010001010000000000000515BI0100001173 | 101.45 | Cu.m |
| 62 | 62 | Shuttering and shoring the earth at different levels in foundations where necessary with required prop, struts, planks, timbers, nails etc. including dewatering if necessary, complete as directed and specified (measurement to be taken in the face area timbered)\n(b) Above 1.5 m upto 3.00 m depth | BI01010001010000000000000515BI0100001174 | 57 | Cu.m |
| 63 | 63 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volume | BI01010001010000000000000515BI0100001175 | 25.8 | Cum |
| 64 | 64 | Providing brick soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.\na) Brick on flat Solling | BI01010001010000000000000515BI0100001176 | 76 | Sq.m |
| 65 | 65 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. | BI01010001010000000000000515BI0100001177 | 104.5 | Sqm |
| 66 | 66 | Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in\n cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed \nincluding bonding, providing face stone, through stone and centering including racking of joints, \ncuring and supplying and all carriage of stone as directed including payment of forest royalty and\n sales tax and carriage. | BI01010001010000000000000515BI0100001178 | 38.3 | Sqm |
| 67 | 67 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nP) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nb) M20 grade concrete or Prop. 1:1.5:3 | BI01010001010000000000000515BI0100001179 | 8.7 | Cum |
| 68 | 68 | Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately) \n(I) Using Mixer Machine\n(B) In super structure from plinth level up to 1st floor level. \nii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.\nP) Using admixture, plasticiser etc for air entraining, water reducing purposes including addition of agent for changing normal setting time of concrete as required.\nb) M20 grade concrete or Prop. 1:1.5:3 | BI01010001010000000000000515BI0100001180 | 4.15 | Cum |
| 69 | 69 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\nii) Using 25mm thick plank | BI01010001010000000000000515BI0100001181 | 57 | Sqm |
| 70 | 70 | Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face | BI01010001010000000000000515BI0100001182 | 82 | Sqm |
| 71 | 71 | Brick work in cement morter with 1st class brick including racking out joints and dewatering if necessary, and curing complete as directed in sub-structure up to plinth level.\nb) In prop 1:4 | BI01010001010000000000000515BI0100001183 | 7.5 | Cum |
| 72 | 72 | 112 mm thick 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)\n(a). In cement mortar in proportion 1:4.(1 cement:4 sand) | BI01010001010000000000000515BI0100001184 | 171 | Sqm |
| 73 | 73 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\n(b). In cement mortar 1:4 | BI01010001010000000000000515BI0100001185 | 182.75 | Sqm |
| 74 | 74 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side\n(b). In cement mortar 1:4 | BI01010001010000000000000515BI0100001186 | 263.35 | Sqm |
| 75 | 75 | Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth complete at all levels as specified and directed. | BI01010001010000000000000515BI0100001187 | 353.78 | Sqm |
| 76 | 76 | Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)\n(i) Thickness = 1.5 mm thick | BI01010001010000000000000515BI0100001188 | 353.75 | Sqm |
| 77 | 77 | a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. | BI01010001010000000000000515BI0100001189 | 353.75 | Sqm |
| 78 | 78 | Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) | BI01010001010000000000000515BI0100001190 | 353.75 | Sqm |
| 79 | 79 | Applying one self-priming coat of acrylic emulsion coating of Unicem \"Rakshak\" brand by thinning 1ltrs of paints with 1ltrs of water over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. | BI01010001010000000000000515BI0100001191 | 353.75 | Sqm |
| 80 | 80 | Supplying and applying interior/exterior walls/ floors/ roofs one coat of Epoxy Primer of Jenson & Nicholson/ Nerolac brand as priming coat after cleaning and clearing the surfaces as specified and directed and then applying two coats of Epoxy paints of Jenson & Nicholson/ Nerolac brand of required shade on walls/ floors/ roof surfaces as specified and directed complete including scaffolding at all levels. | BI01010001010000000000000515BI0100001192 | 353.75 | Sqm |
| 81 | 81 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\nb). High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). | BI01010001010000000000000515BI0100001193 | 670.8 | Sqm |
| 82 | 82 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(i) TMT Corrosion resistant steel (CRS) reiforcement bar | BI01010001010000000000000515BI0100001194 | 12.48 | Qtt |
| 83 | 83 | Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 40mm x 40mm x 6mm M.S. angle and with M.S. flat of 40mm x 6mm size as per approved design.Necessary locking arrangement for temporary closing the gate and 2nos.( minimum) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embedded in C.C brick pillers as necessary including a red oxide painting to all iron works as directed and specified.(Separate payment will be made for posts). | BI01010001010000000000000515BI0100001195 | 4.41 | qtl |
| 84 | 84 | Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer. | BI01010001010000000000000515BI0100001196 | 17.64 | Sqm |
| 85 | 85 | Providing fitting and fixing Vitreous china wall hang water closet (European type W.C pan 400mm high) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)\nC) Jaquar make\nI) White\n(vii) Kubix (Cat. No.KUS-WHT-0311) (inclusive of seat cover and fittings) | BI01010001010000000000000515BI0100001197 | 6 | Each |
| 86 | 86 | Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)\n(C) Jaquar Make\nConcealed Cistern (Cat.No.CIB-WHT-31801011X) with Control Plate (CP) (Cat. No. CIS-CHR-31191510X) | BI01010001010000000000000515BI0100001198 | 6 | Each |
| 87 | 87 | Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nWall Hang Basin\n(C) Jaquar Make\n(iii) Kubix (Cat.No.KUS-WHT-0608) (470 x 450 x 350) | BI01010001010000000000000515BI0100001199 | 10 | Each |
| 88 | 88 | Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)\nTable Top Basin\n(C) Jaquar Make\n(iv) Kubix (Cat.No.KUS-WHT-0552) | BI01010001010000000000000515BI0100001200 | 2 | Each |
| 89 | 89 | Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately\nA) Parryware make\n(i) Single Bowl with Veg Bowl & Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545) | BI01010001010000000000000515BI0100001201 | 1 | Each |
| 90 | 90 | Providing fitting and fixing Decorative Mirror complete as directed and specified.\n(B) Jaquar Make \n(a) Double Arm Wall Mounted reversible plain / Magnifying (3X) Pivotal Mirror (Cat. No.ACN-1193N) | BI01010001010000000000000515BI0100001202 | 6 | Each |
| 91 | 91 | Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified.\n(i) Jaquar Make\n(a) Continental (Cat.No.ACN-1135N) (with glass bottle) | BI01010001010000000000000515BI0100001203 | 6 | Each |
| 92 | 92 | Providing, fitting and fixing Chrome Plated towel rack complete as directed and specified.\n(a) Jaquar make \n(i) Continental 600mm long with hanger (Cat.No. ACN-1181N) | BI01010001010000000000000515BI0100001204 | 6 | Each |
| 93 | 93 | Providing, fitting and fixing Chrome Plated brush holder complete as directed and specified.\n(a) Jaquar make \n(i) Continental (Cat.No. ACN-1143N) | BI01010001010000000000000515BI0100001205 | 6 | Each |
| 94 | 94 | Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.\n(a) Jaquar make\n(i) 32mm (HT/FT) (Cat.No.ALD-705 / 709) | BI01010001010000000000000515BI0100001206 | 6 | Each |
| 95 | 95 | Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified.\n(a) Jaquar make\n(ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B) | BI01010001010000000000000515BI0100001207 | 6 | Each |
| 96 | 96 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | BI01010001010000000000000515BI0100001208 | 30 | Each |
| 97 | 97 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 75mm dia. | BI01010001010000000000000515BI0100001209 | 10 | Each |
| 98 | 98 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia. | BI01010001010000000000000515BI0100001210 | 9 | Each |
| 99 | 99 | Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 75mm dia. | BI01010001010000000000000515BI0100001211 | 3 | Each |
| 100 | 100 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | BI01010001010000000000000515BI0100001212 | 30 | Each |
| 101 | 101 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(iv) 75mm dia. | BI01010001010000000000000515BI0100001213 | 10 | Each |
| 102 | 102 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia. | BI01010001010000000000000515BI0100001214 | 9 | Each |
| 103 | 103 | Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 75mm dia. | BI01010001010000000000000515BI0100001215 | 3 | Each |
| 104 | 104 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | BI01010001010000000000000515BI0100001216 | 30 | Each |
| 105 | 105 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 75mm dia. | BI01010001010000000000000515BI0100001217 | 10 | Each |
| 106 | 106 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia. | BI01010001010000000000000515BI0100001218 | 9 | Each |
| 107 | 107 | Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 75mm dia. | BI01010001010000000000000515BI0100001219 | 3 | Each |
| 108 | 108 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia. | BI01010001010000000000000515BI0100001220 | 30 | Each |
| 109 | 109 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 75mm dia. | BI01010001010000000000000515BI0100001221 | 10 | Each |
| 110 | 110 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia. | BI01010001010000000000000515BI0100001222 | 9 | Each |
| 111 | 111 | Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \nb) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 75mm dia. | BI01010001010000000000000515BI0100001223 | 3 | Each |
| 112 | 112 | Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.\n(iv) 75mm dia. PVC cowel of ISI make | BI01010001010000000000000515BI0100001224 | 5 | Each |
| 113 | 113 | Providing fiting & fixing C.I. Grating to the floors complete as directed and specified.\n(b) 75mm dia | BI01010001010000000000000515BI0100001225 | 7 | Each |
| 114 | 114 | Supplying, fitting and fixing Kitchen chimney including water proof ply board, plain sheet, decorative prelaminated sheet, nail, fevicol, dendrite, wooden beading etc.as required complete as specified and directed by the department. | BI01010001010000000000000515BI0100001226 | 1 | Each |
| 115 | 115 | Supplying fitting and fixing wall mounted shower panel of Jaquar make complete with thermostic mixer, 3 round body showers, hand shower, rain shower with extended shower arm and cast aluminium body as directed.\n(ii) Jump Top | BI01010001010000000000000515BI0100001227 | 4 | Each |
| 116 | 116 | Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 19 Kg. weight complete as directed and specified | BI01010001010000000000000515BI0100001228 | 4 | Each |
| 117 | 117 | Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table. | BI01010001010000000000000515BI0100001229 | 1 | Each |
| 118 | 118 | Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed. | BI01010001010000000000000515BI0100001230 | 10 | Each |
| 119 | 119 | Supplying and placing ferrocement septic tanks of rectangular shape in to pit with manhole cover with cleaning arrangement over single brick flat soling and 75mm 1:3:6 P.C.C. Baffle wall, inlet and outlet etc are provided at suitable points complete as directed. \n(viii) 100 Users | BI01010001010000000000000515BI0100001231 | 2 | Each |
| 120 | 120 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(A)) Exposed or in trenches\nb) 20 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001232 | 40 | R.m |
| 121 | 121 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(A)) Exposed or in trenches\nd) 32 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001233 | 50 | R.m |
| 122 | 122 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(A)) Exposed or in trenches\nf) 50 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001234 | 80 | R.m |
| 123 | 123 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(B) Concealed pipe with cutting chases & making good the walls\nb) 20 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001235 | 15 | R.m |
| 124 | 124 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(B) Concealed pipe with cutting chases & making good the walls\nd) 32 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001236 | 20 | R.m |
| 125 | 125 | Providing and fixing Chlorinated Polyvinyle Chloride (CPVC) Pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipe\n(B) Concealed pipe with cutting chases & making good the walls\nf) 50 mm nominal outer dia pipe | BI01010001010000000000000515BI0100001237 | 30 | R.m |
| 126 | 126 | Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately) \nII) Jaquare make \n(a)Continental /Clarion\n(iii)2-Way bib cock | BI01010001010000000000000515BI0100001238 | 17 | Each |
| 127 | 127 | Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately) \nII) Jaquare make \n(a)Continental /Clarion\n(i)15mm dia Male / Female (long thread) | BI01010001010000000000000515BI0100001239 | 17 | Each |
| 128 | 128 | Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. \nII) Jaquare make \n(a)Continental /Clarion\n(b)Long neck with areator | BI01010001010000000000000515BI0100001240 | 17 | Each |
| 129 | 129 | Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid separately) \nV) Jaquare make \n(a)Continental /Clarion\ni) Sink cock with swinging casted spout | BI01010001010000000000000515BI0100001241 | 17 | Each |
| 130 | 130 | Supplying fitting and fixing Chrome Plated (C.P.) flush cock of approved brand as directed and specified.(G.I. & C.P pipes will be measured and paid separately) \nIII) Jaquar brand \nc).Stealth Rangers - flush cock with wall flange 25mm with plain knob (For VIP use. Prior approval of Chief Engineer PWD (Bldg) must be taken before use) | BI01010001010000000000000515BI0100001242 | 5 | Each |
| 131 | 131 | Supplying fitting and fixing overhead adjustable Chrome Plated (C.P.) spray shower 15mm dia. of Sona make with wall flange as directed and specified.(pipes will be measured and paid separately)\n(a) Supreme shower with arm | BI01010001010000000000000515BI0100001243 | 5 | Each |
| 132 | 132 | Supply, Installation, Testing & Commissioning of Thermostate- Grotherm 1000 Thermostate wall mixer with pre-set temperature facility and GROHE Turbostate , cool touch, Temperature Control technology.Cat no-34215000\nCat no-34215000 | BI01010001010000000000000515BI0100001244 | 5 | Each |
| 133 | 133 | Supplying, fitting and fixing Chrome Plated (C.P.) divertor of approved brand complete as directed. \n(II) Jaquar make \nc)Stealth Rangers - 4-way divertor for concealed fitting with built in non return valves (For VIP use only. Prior approval of Chief Engineer PWD (Bldg) must be taken before use)Cat No. 21421 | BI01010001010000000000000515BI0100001245 | 5 | Each |
| 134 | 134 | Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.\na) 50mm dia | BI01010001010000000000000515BI0100001246 | 15 | Each |
| 135 | 135 | Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes\nI) 2000 Lt capacity\n(a) Sintex make | BI01010001010000000000000515BI0100001247 | 5 | Each |
| 136 | 136 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. \nShort point up to 3.00 metre. length. | BI01010001010000000000000515BI0100001248 | 647 | Each |
| 137 | 137 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. \nMedium point up to 6.00 metre. Length. | BI01010001010000000000000515BI0100001249 | 916 | Each |
| 138 | 138 | Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. \nLong point up to 10.00 metre. Length. | BI01010001010000000000000515BI0100001250 | 1306 | Each |
| 139 | 139 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\nShort point up to 3.00 metre. length. | BI01010001010000000000000515BI0100001251 | 681 | Each |
| 140 | 140 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\nMedium point up to 6.00 metre. Length. | BI01010001010000000000000515BI0100001252 | 993 | Each |
| 141 | 141 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\nLong point up to 10.00 metre. Length. | BI01010001010000000000000515BI0100001253 | 1431 | Each |
| 142 | 142 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.\nLong point up to 10.00 metre. Length. | BI01010001010000000000000515BI0100001254 | 2245 | Each |
| 143 | 143 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nExtra long point up to 15.00 metre. length. | BI01010001010000000000000515BI0100001255 | 2999 | Each |
| 144 | 144 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nExtra long point up to 20.00 metre. Length. | BI01010001010000000000000515BI0100001256 | 4338 | Each |
| 145 | 145 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt./ Havells make), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)\nExtra long point up to 25.00 metre. Length. | BI01010001010000000000000515BI0100001257 | 5443 | Each |
| 146 | 146 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | BI01010001010000000000000515BI0100001258 | 188 | Metre. |
| 147 | 147 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | BI01010001010000000000000515BI0100001259 | 303 | Metre. |
| 148 | 148 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.\nWith 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit. | BI01010001010000000000000515BI0100001260 | 506 | Metre. |
| 149 | 149 | Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan. | BI01010001010000000000000515BI0100001261 | 135 | Each |
| 150 | 150 | Wiring for twin control light point with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 amp flush type 2 way switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete\nMedium point up to 6.00 metre. Length. | BI01010001010000000000000515BI0100001262 | 1020 | Each |
| 151 | 151 | Fitting and fixing of brackets on the wall in GI/ MS switch board (ISI marked) half conceal on wall with phenolic laminated sheet cover with all accessories such as GI/ MS switch board (ISI marked) with phenolic laminated sheet cover including connection as approved by the Deptt.)as required complete. [BK] | BI01010001010000000000000515BI0100001263 | 162 | Each |
| 152 | 152 | Supplying and fixing of 250/305 mm dia (Nominal size flush type circular ceiling fittings complete with holder, Aluminium anodized back plate and brass holder, 20 Watt CFL lamp including connection as approved by the Deptt.)as required. [CLP] | BI01010001010000000000000515BI0100001264 | 705 | Each |
| 153 | 153 | Supplying and fitting of 11/15 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. | BI01010001010000000000000515BI0100001265 | 193 | Each |
| 154 | 154 | Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. | BI01010001010000000000000515BI0100001266 | 227 | Each |
| 155 | 155 | Supplying and fixing of Frosted glass shade of 100 mm dia (Nominal Size as required. | BI01010001010000000000000515BI0100001267 | 77 | Each |
| 156 | 156 | Supplying and fixing of Fan box (AKG or equivalent as approved by the Deptt.) with inbuild rod as required. | BI01010001010000000000000515BI0100001268 | 128 | Each |
| 157 | 157 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n12 way SPN double door | BI01010001010000000000000515BI0100001269 | 2025 | Each |
| 158 | 158 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n4 way TPN (4+12) double door | BI01010001010000000000000515BI0100001270 | 3370 | Each |
| 159 | 159 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n8 way TPN (4+24) double door | BI01010001010000000000000515BI0100001271 | 4479 | Each |
| 160 | 160 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting vertical TPN MCB DB incorporated with bas-bar 125A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.\nABB, Schneider MG, legrand, Hager make)\n4 way TPN (8+12) double door | BI01010001010000000000000515BI0100001272 | 6704 | Each |
| 161 | 161 | Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series(Schneider MG, legrand, Hager make)\n6 to 32A | BI01010001010000000000000515BI0100001273 | 231 | Each |
| 162 | 162 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series(ABB, Schneider MG, legrand, Hager make)\n6 to 32A | BI01010001010000000000000515BI0100001274 | 615 | Each |
| 163 | 163 | Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series(ABB, Schneider MG, legrand, Hager make)\n6 to 32A | BI01010001010000000000000515BI0100001275 | 912 | Each |
| 164 | 164 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\nC Series (ABB, Schneider MG, legrand, Hager make)\n6 to 32 | BI01010001010000000000000515BI0100001276 | 1516 | Each |
| 165 | 165 | Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n30mA sensitivity DP RCCB(ABB, Schneider MG, legrand, Hager make)\n25A | BI01010001010000000000000515BI0100001277 | 2423 | Each |
| 166 | 166 | Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.\n25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make)\n40A | BI01010001010000000000000515BI0100001278 | 5664 | Each |
| 167 | 167 | Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.\n25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make)\n63A | BI01010001010000000000000515BI0100001279 | 5664 | Each |
| 168 | 168 | Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].\nStandard model 1200 mm Sweep Usha make)/ Standard model 1050 / 1200 mm Sweep Havells make)/ High speed 1200 mm sweep (ORIENT PSPO make) | BI01010001010000000000000515BI0100001280 | 1908 | Each |
| 169 | 169 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.\nDomestic\nTrans Air 300 mm sweep (Crompton make) | BI01010001010000000000000515BI0100001281 | 1887 | Each |
| 170 | 170 | Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.\n1-2 module type Metal | BI01010001010000000000000515BI0100001282 | 104 | Each |
| 171 | 171 | Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.\n2 module | BI01010001010000000000000515BI0100001283 | 108 | Each |
| 172 | 172 | Supplying with fitting and fixing of 25A Modular Motor Starter 2M , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department. | BI01010001010000000000000515BI0100001284 | 858 | Each |
| 173 | 173 | Compact CFL luminaries complete with Serrated diffuser & Decorative coloured end caps and Electronic ballast with 1 X 11 W CFL (Crompton Greaves make Model- TLN11/ W MINI MIRRORLITE or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make). [ML] | BI01010001010000000000000515BI0100001285 | 642 | Each |
| 174 | 174 | Sleek Strip type Decorative T5 luminaries with ABS end caps and Electronic ballast with 1 X 28 W T5 lamp(Crompton Greaves make Model- T5SG1128EB / B OR T5SG1128EB / O CG SLIM GOLD or equivalent (Equivalent will be selected by the deptt considering the mother items rate) (equivalent PHILIPS/ WIPRO/ BAJAJ/ Havells/ HPL/ SOLAR/ JAQUAR make). | BI01010001010000000000000515BI0100001286 | 743 | Each |
| 175 | 175 | Supplying, installation, testing and commissioning of Slim surface mounted round LED panel al. die cast body with premium diffuser to ensure glare free & even distribution of light of make Havells Model Comet Round Cat No. 12W LED 3000K LHEAAVP5IL1W012 in the ceiling with all accessories including including making necessary connection with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. [CLC] | BI01010001010000000000000515BI0100001287 | 2105 | Each |
| 176 | 176 | Supplying, installation, testing and commissioning of Slim, compact, auminum die cast edge lit panel. Recess mounted round fixture with opal diffuser and separate electronic driver of make Havells Model Octane LED Panel Round Cat No. 15W LED 4000K LHEBHDP6IZ1W015 in the ceiling with all accessories including including making necessary connection with 1.5 sq. mm PVC insulated single core copper conductor as reqd. and as directed by the Deptt. [CLL] | BI01010001010000000000000515BI0100001288 | 1609 | Each |
| 177 | 177 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .\n3 & 1/2 Core A2XFY\n25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable | BI01010001010000000000000515BI0100001289 | 468 | Metre |
| 178 | 178 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .\n3 & 1/2 Core A2XFY\n35.00 Sq. mm.3 & 1/2 Core armoured U.G. cable | BI01010001010000000000000515BI0100001290 | 541 | Metre |
| 179 | 179 | Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .\n3 & 1/2 Core A2XFY\n95.00 Sq. mm.3 & 1/2 Core armoured U.G. cable | BI01010001010000000000000515BI0100001291 | 972 | Metre |
| 180 | 180 | Supplying including installation, commissioning of vermin and dust proof totally enclosed, Phosphatised Powder Painted cubical outdoor type double door, floor mounting compartmentalize panel board of size 0.8M X0.8MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 35mm X 35mm X 5mm size angle having 4 no legs at the bottom and C.R. sheet roofing on the top. The panel board is to be erected in 1 : 3 : 6 PCC foundation including excavation of trench and brick soling etc. complete neatly Wiring done with provision for one no 315/400A 4pole MCCB or Switch Fuse Unit as incomer and out going as specified and directed by the deptt. confirming to IP 65 protection comprising of the following electrical items:\n1. 40mm X 5mm (4X2) strip copper Bus-Bar 0.20M length each\n2. Digital 3 Phase Voltmeter Accuracy class 0.5 - 1 no\n3. Digital 3 Phase Ammeter Accuracy class 0.5 - 1 no\n4. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no\n5. Voltmeter & Ammeter Selector Switch - 2 no\n6. 2 A Slide fuse unit - 3nos\n(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately) | BI01010001010000000000000515BI0100001292 | 23714 | Each |
| 181 | 181 | Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.\n35/36 KA 415V 50 Hz 3P MCCB (ABB(S6) , Schneider, legrand, Siemens, L&T D-shine make)\n160A | BI01010001010000000000000515BI0100001293 | 12850 | Each |
| 182 | 182 | Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . | BI01010001010000000000000515BI0100001294 | 5431 | Each |
| 183 | 183 | Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. | BI01010001010000000000000515BI0100001295 | 2804 | Each |
| 184 | 184 | Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. | BI01010001010000000000000515BI0100001296 | 28 | Metre. |
| 185 | 185 | Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt. | BI01010001010000000000000515BI0100001297 | 149 | Metre. |
| 186 | 186 | Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt. | BI01010001010000000000000515BI0100001298 | 1252 | Each |
| 187 | 187 | Executive table | BI01010001010000000000000515BI0100001299 | 1 | Each |
| 188 | 188 | Easy Chair T20 (for conference hall) | BI01010001010000000000000515BI0100001300 | 18 | Each |
| 189 | 189 | Visitor Chair | BI01010001010000000000000515BI0100001301 | 20 | Each |
| 190 | 190 | Onyx Sofa Black PU/Burgundy (3+1+1) | BI01010001010000000000000515BI0100001302 | 2 | Each |
| 191 | 191 | OPAL Centre table | BI01010001010000000000000515BI0100001303 | 2 | Each |
| 192 | 192 | Bed | BI01010001010000000000000515BI0100001304 | 2 | Each |
| 193 | 193 | King size bed with poshing and mica | BI01010001010000000000000515BI0100001305 | 2 | Each |
| 194 | 194 | Spider 4 seater dining set | BI01010001010000000000000515BI0100001306 | 3 | Each |
| 195 | 195 | 3door wadrobe 48\" | BI01010001010000000000000515BI0100001307 | 2 | Each |
| 196 | 196 | Matress (curl on) 72 X 72, 6\" | BI01010001010000000000000515BI0100001308 | 4 | Each |
| 197 | 197 | Bed Sheet | BI01010001010000000000000515BI0100001309 | 4 | Each |
| 198 | 198 | Bed cover | BI01010001010000000000000515BI0100001310 | 8 | Each |
| 199 | 199 | Pillow | BI01010001010000000000000515BI0100001311 | 8 | Each |
| 200 | 200 | Pillow Cover | BI01010001010000000000000515BI0100001312 | 8 | Each |
| 201 | 201 | Blanket | BI01010001010000000000000515BI0100001313 | 4 | Each |
| 202 | 202 | TV | BI01010001010000000000000515BI0100001314 | 2 | Each |
| 203 | 203 | Modular Kitchen | BI01010001010000000000000515BI0100001315 | 1 | Each |
| 204 | 204 | Kitchen Utensil Item | BI01010001010000000000000515BI0100001316 | 1 | L/S |
| 205 | 205 | Refrigerator | BI01010001010000000000000515BI0100001317 | 1 | Each |
| 206 | 206 | TV/LCD trolly, size 3ft with 2shutters (one wooden and two glass shutters) | BI01010001010000000000000515BI0100001318 | 3 | Each |
AI Tender Summary
Tender Timeline
Feb 08, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 17, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 18, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender