Youth Affairs and Sports and Culture Government Departments Closing in 0 days TDR #23546884

Construction Of Dr . B . R . Ambedkar Bhawan At Gohpur Sub Division

Issued by Government Departments · Gohpur, Assam
Tender Value
1.76 Crore
Estimated cost
Bid Submission
15 Feb 2020
0 days left
EMD
88.12 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Auction
Location / State
Gohpur → Assam
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Dr . B . R . Ambedkar Bhawan At Gohpur Sub Division

BOQ

Name of Work: Construction of Dr. B. R. Ambedkar Bhawan at Gohpur
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11Civil WorksHead 1
22Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soilitem 1300Cum
33Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2mitem 2105Cum
44Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.item 335Cum
55Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid sepaAPWD Rately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 413Cum
66Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. \nc) 100mm thickitem 5250Cum
77Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc.item 640Sqm
88Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid sepaAPWD Rately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\n i) M20 Grade Prop 1:1.5:3item 754Cum
99Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid sepaAPWD Rately) \n(I) Using Mixer Machine\n(A) In substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nN) Without using admixture, plasticiser\n i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc.item 880Cum
1010Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.item 920Cum
1111Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\n(b) Using 25mm thick plankitem 1098Sqm
1212Sides of tie beams, grade beams etc. at or below ground level.\n(b) Using 25mm thick plankitem 11145Sqm
1313Columns, Pillars, Posts & Strut\n(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face\n(ii) Using 25mm thick plankitem 12165Sqm
1414Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.\n(a) For depth not exceeding 1.0M.\n(ii) Using 25mm thick plankitem 13372Sqm
1515Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.\n(a) Floors etc. upto 200mm in thickness.\n(ii) Using 25mm thick plankitem 14245Sqm
1616Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank)item 1524Sqm
1717Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.1 & 3.1.3(b).item 16217Sqm
1818Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4.item 1727Cum
19191st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid sepaAPWD Rately) \n(A) 112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)item 18685Sqm
2020Extra for brick walling for each subsequent floor or part thereof above the 1st floor level.\n(a) 112mm thick brick/ R.B wallitem 1929.09Sqm
2121Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. \n(a) With sal wooditem 201Cum
2222Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. \nb) Non decorative type and block board core.\n(ii) 35 mm thick .item 2137Sqm
2323Providing barge board of size 200mm x 20mm with 1st class local Hollock/ Bonsum timber including fitting and fixing with necessary wood screws etc. complete.item 2266RM
2424Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels.item 2365RM
2525Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid sepeAPWD Rately)\nb) 29mm thickitem 2421Sqm
2626Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the APWD Rate) (Upto 1st floor level) \na) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL\n(ii)Super Ductile (SD) TMT reinforcement barsitem 25186Qtl
2727Extra over item 18.1.1(a,b,c) for each subsequent floor or part thereof above first floor level.item 2642Qtl
2828Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.\nI . Plain grill\n(c) Fixed to Brickwork/P.C.C/R.C.C.item 27370Qtl
2929Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. \na) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998item 2840Qtl
3030Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).\nExecutive range\nSomany/ Orient/Nitco/Asian Make\nOf size 300mmx300mm and aboveitem 29130Sqm
3131roviding VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)\na) Normal range \nSomany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make\nii) Of size 600mmx600mm and aboveitem 30364Sqm
3232Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.\n(A) CERAMIC\ni)Normal range (Sizes 300 mm x 300mm and above)\n (a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slateitem 3150.3Sqm
333318 mm thick marble stone tiles in flooring including risers and treads of steps, skirting, dado, walls, pillars laid with 10 mm thick base of cement plaster in prop.1:3 ( I cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing complete with marble tiles of specified quality and shade at all levels.\n(a) With 18mm thick marble stone tiles of size 600mm x 600 mm\n(iii) Kumari Marbleitem 3238Sqm
343410 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.\na) In cement mortar 1:3item 33275Sqm
353515 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nA) On rough side\na) In cement mortar 1:3item 34330Sqm
363615 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nB) On fair side\nb) In cement mortar 1:4item 35330Sqm
373720 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\nb) In cement mortar 1:4item 36115Sqm
383820 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nB) On fair side (backing coat 10 mm and finishing coat 10mm thick)\nb) In cement mortar 1:4item 37115Sqm
393920 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nA) On rough side (backing coat 15 mm and finishing coat 5mm thick)\nb) In cement mortar 1:4item 38205Sqm
404020 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. \nB) On fair side (backing coat 10 mm and finishing coat 10mm thick)\nb) In cement mortar 1:4\nitem 39200Sqm
4141Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed.\nii) 15 mm thick plaster\nb) In cement mortar 1:4item 40275Sqm
4242Extra over item no 6.2.1to 6.2.3 for interior plastering above 1st floor level for every addl floor or part thereof including curing complete as directed.\nb) On two coat plasteritem 41365Sqm
4343Providing two coats of J.K Wall Putty ( White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)item 421165Sqm
4444Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)item 431165Sqm
4545Applying one self-priming coat of Unicem \"Shakti\" brand of required shade over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department.item 44405Sqm
4646Finishing wall with two coats of waterproofing cement coatings of Unicem \"Shakti\" brand of required shade by thinning 1 part of paint with 1 part of water to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department.item 45405Sqm
4747Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting. \n(b). With ready mixed paint , wood primer (white).item 4674Sqm
4848Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.\n(i).Surfaces over 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).item 4774Sqm
4949Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.\na). With ready mixed \"red-lead/ red oxide\" primer.item 48300Sqm
5050Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.\n(i).Surfaces over 100mm in width or girth.\na). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).item 49300Sqm
5151Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid sepaAPWD Rately).\na)Side hung and Top hung windows and ventilators\n(iv) 5 mm clear glassitem 5015Sqm
5252Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid sepaAPWD Rately).\na)Side hung and Top hung windows and ventilators(v) 5 mm coloured glassitem 515Sqm
5353Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid sepaAPWD Rately).\na)Side hung and Top hung windows and ventilators(ii)5mm Frosted Glassitem 525Sqm
5454Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid sepaAPWD Rately).\na)Side hung and Top hung windows and ventilators(ii)5mm Clear Glassitem 5335Sqm
5555Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(a)2 Track sliding window\n(ii)5mm frosted glassitem 54100Sqm
5656Providing, fitting and fixing coloured anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars,joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.\n(b)3 Track sliding window\n(ii)5mm frosted glassitem 55210Sqm
5757Providing and fixing anodised aluminium framed double leaf doors of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mm x15mm x1.2mm complete with automatic floor mounted door closure, butterfly type handles, special cylindrical lock, concealed type aluminium tower bolt,neoprene dryset rubber gusket, door felt gusket, etc.complete as directed by the Department at all levels. \n(iv)6mm coloured glassitem 5635Sqm
5858Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels.\n(ii)6mm clear glassitem 57120Sqm
5959Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\n a) Sliding door bolts\ni) 300mm x 16mmitem 5830Sqm
6060Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nb) Tower bolts\nii) 250mm x 12mmitem 59450Sqm
6161Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nc) Door handles\niii) 150mmitem 60225Sqm
6262Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )\nt) Door stopper with rubber stopperitem 6175Sqm
6363Providing and fixing, in position suspended false ceiling using E-Grid (exposed ceiling suspension 2430 system) of grid size 600mm x 600mm/1200mmx600mm with main runner 38 x 24mm, cross tee 29mm x 24mm & wall angle 24mm x 24mm . Using 4mm/6mm thick High Pressure Steam Cured Non Asbestos Fibre Cement Board as per IS 14862, to be placed in a grid of G.I. system duly suspended with 4mm/6mm dia G.I/M.S bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures, air conditioning diffuser and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at more than 450mm from the adjacent wall. Flush fitting 1220mm cross tee to be interlocked between main runners @ 610mm c/c, so as to form 600mm x 600mm/1200mmx600mm grid, all complete as per the drawing & directions of engineer-in-charge. \nFinally, if specified, boards are to be painted with 2 coats of acrylic emulsion paint of approved shade/make over a coat of cement primer before installing it on the grid.\n(B) Designer Ceilings of Everest make or equivalent as directed by the departement\n(i) Using 4 mm thick FC Boarditem 62250Sqm
6464Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid sepaAPWD Rately). \n(b) 0.50 mm thickitem 63345Sqm
6565Providing galvd iron ridging of TATA SHAKTEE / SAIL including supplying and fixing necessary galvd screws/washers etc. complete as directed.\n(b) 0.50 mm thick \n(i) 150 mm lappingitem 6460Sqm
6666Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.item 65250Sqm
6767Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.\nii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.item 66256Sqm
6868Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed.\nb) 75mm thick slabitem 6730Sqm
6969Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.\na) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.item 68250Sqm
7070Approach RoadHead 2
7171Removal of Unserviceable Soil with Disposal upto 1000 metres\n(Removal of unserviceable soil including excavation, loading and\ndisposal upto 1000 metres lead but excluding replacement by\nsuitable soil which shall be paid sepaAPWD Rately as per clause 305.)item 6970Cum
7272Construction of Subgrade and Earthen Shoulders (Construction\nof subgrade and earthen shoulders with approved material obtained\nfrom borrow pits with all lifts & leads, transporting to site, spreading,\ngrading to required slope and compacted to meet requirement of\ntable\nfrom Private landitem 7060Cum
7373Construction of granular sub-base by providing\nclose graded Material, mixing in a mechanical mix plant at OMC,\ncarriage of mixed Material to work site, spreading in uniform layers\nwith motor grader on prepared surface and compacting with\nvibratory power ritem 7130Cum
7474Water Bound Macadam (Providing, laying, spreading and\ncompacting stone aggregates of specific sizes to water bound\nmacadam specification including spreading in uniform thickness,\nhand packing, rolling with vibratory roller 8-10 tonnes in stages to\nproper grade and camber, applying and brooming requisite type of\nscreening/binding material to fillup the interstices of coarse\naggregate,watering and compacting to the reqd. density ( with an\ninitial lead of 5.0 km. )\nGrading- IIIitem 7215Cum
7575Providing and laying interlocking concrete block pavement having thickness 80mm as\nper technical specification clause 1504item 73200Cum
7676CourtyardHead 3
7777Removal of Unserviceable Soil with Disposal upto 1000 metres\n(Removal of unserviceable soil including excavation, loading and\ndisposal upto 1000 metres lead but excluding replacement by\nsuitable soil which shall be paid sepaAPWD Rately as per clause 305.)item 7470Cum
7878Construction of Subgrade and Earthen Shoulders (Construction\nof subgrade and earthen shoulders with approved material obtained\nfrom borrow pits with all lifts & leads, transporting to site, spreading,\ngrading to required slope and compacted to meet requirement of\ntable (300-2 ( Including cost of testing of materials at site and\nlaboratory as directed by the deptt.)\n(a) from private landitem 75100Cum
7979Construction of granular sub-base by providing\nclose graded Material, mixing in a mechanical mix plant at OMC,\ncarriage of mixed Material to work site, spreading in uniform layers\nwith motor grader on prepared surface and compacting with\nvibratory power roller to achieve the desired density,completeas per\ncl. 401( with an initial lead of 5 Km.)( Including cost of testing of\nmaterials at site and laboratory as directed by the deptt.)\nfor grading- II Materialitem 7650Cum
8080Water Bound Macadam (Providing, laying, spreading and\ncompacting stone aggregates of specific sizes to water bound\nmacadam specification including spreading in uniform thickness,\nhand packing, rolling with vibratory roller 8-10 tonnes in stages to\nproper grade and camber, applying and brooming requisite type of\nscreening/binding material to fillup the interstices of coarse\naggregate,watering and compacting to the reqd. density ( with an\ninitial lead of 5.0 km. )\nGrading- IIIitem 7725Cum
8181Providing and laying interlocking concrete block pavement having thickness 80mm as\nper technical specification clause 1504item 78250Cum
8282Boundary WallHead 4
8383Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.\n(A) Up to a depth of 2.00m below the existing ground level.\n(a) In ordinary soilitem 79325.8Cum
8484Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage.\n(a) Random Rubble Masonryitem 80282.36Cum
8585Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.\n(a) With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2mitem 81184.62Cum
8686Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid sepaAPWD Rately).\n(a) In prop 1cement: 3 sand :6 coarse aggregate by volumeitem 8228.236Cum
8787Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid sepaAPWD Rately)\nUsing Mixer Machine\nIn substructure up to plinth level\nFoundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.\nWithout using admixture, plasticiser\nM15 grade concrete or Prop. 1:2.4 col col. Below tie beamitem 8338.01Cum
8888In super structure from plinth level up to 1st floor level. \nN) Without using admixture, plasticiser\nM15 grade concrete or Prop. 1:2:4item 8421.72Cum
8989Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:\nFoundation, footings, bases of columns, pile cap, raft and mass concrete works etc.\nSides of tie beams, grade beams etc. at or below ground level.\nSides of tie beams, grade beams etc. at or below ground level.\nUsing 25mm thick plankitem 85217.2Cum
9090Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:\nColumns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical faceitem 86274.396Cum
9191Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.item 8758.463Cum
9292Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.\n(I) In Sub-structure upto plinth level including dewatering if necessary\n(b) In proportion 1:4.item 8847.603Cum
93931st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid sepaAPWD Rately)\n112mm thick brick wall\n(a) In cement mortar in proportion 1:4. \n(1 cement:4 sand)item 89323.266Cum
949415 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. \nOn rough side\nIn cement mortar 1:item 90688.705Cum
9595Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.\n(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)- 2 coatsitem 91688.708Cum
9696b) Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on new wall surface (two coats) to give an even shade after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials.item 92688.705Cum
9797Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete.\n(No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the APWD Rate) \nb) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX)\n .item 9351.042Cum
9898Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (SepaAPWD Rate payment will be made for posts).item 944.33Cum
9999Sanitary and Water SupplyHead 5
100100Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid sepaAPWD Rately)\nA) Parryware make \na) White\n(i) Universal Closet S Trap (Cat No.C0271) (Anglo Indian) (inclusive of seat cover)item 9528Each
101101Providing fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.\nB) Hindware make\na) White\n(ii)URINAL ALEXA E-Sense (Cat. No.96005)item 9624Each
102102Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.item 972Each
103103Providing fitting and fixing Glass Shelf complete as directed and specified.\nGlass shelf with C.P. guard rail \n(ii) Sona make (Cat. No.TR-0701\n(b) 525mmitem 9833Each
104104Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified.\n(b) Sona Make\n(i) Soap dish light (Cat.No.TR-0661)item 9933Each
105105Providing, fitting and fixing CP towel rail complete as directed and specified.\n(a) Jaquar make\n(iv) Queen's (450mm long) (Cat.No.AQN-7711A)item 10033Each
106106Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.\n(a) Jaquar make \n(i) Continental toilet paper holder (Cat.No. ACN-1151N)item 10133Each
107107Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 160mm dia.item 102180Each
108108Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. (ii) 110mm dia.item 103110Each
109109Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. (iv) 75mm dia.item 10450Each
110110b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 160mm dia.item 10540Each
111111b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.item 106130Each
112112b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 75mm dia.item 10750Each
113113Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 160mmitem 10828Each
114114Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.item 10916Each
115115Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 75 mm dia.item 11018Each
116116b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damage\n(i) 160mmitem 11120Each
117117(ii) 110mm dia.item 11221Each
118118(iv) 75 mm dia.item 11319Each
119119Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(i) 160mm diaitem 11428Each
120120(ii) 110mm dia.item 11533Each
121121b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 160mm diaitem 11610Each
122122(ii) 110mm dia.item 1178Each
123123Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 160mm diaitem 11814Each
124124(ii) 110mm dia.item 11912Each
125125(iv) 75 mm dia.item 1208Each
126126b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 160mm diaitem 12126Each
127127(ii) 110mm dia.item 12228Each
128128(iv) 75 mm dia.item 12325Each
129129Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 160mm diaitem 12412Each
130130(ii) 110mm dia.item 1258Each
131131(iv) 75 mm dia.item 1268Each
132132b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 160mm diaitem 12734Each
133133(ii) 110mm dia.item 12833Each
134134(iv) 75 mm dia.item 12935Each
135135Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(ii) 110mm dia.item 13015Each
136136(iv) 75 mm dia.item 13115Each
137137b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(ii) 110mm dia.item 13215Each
138138(iv) 75 mm dia.item 13312Each
139139Supplying fiting and fixing PVC cross ‘T’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(i) 110mm x110mmitem 1348Each
140140(ii) 75 mm x 75mmitem 1358Each
141141b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 110mm x110mmitem 13618Each
142142(ii) 75 mm x 75mmitem 13718Each
143143Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches\n(i) 110 mm diaitem 13812Each
144144(iii) 75 mm diaitem 1398Each
145145b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(i) 110 mm diaitem 14024Each
146146(iii) 75 mm diaitem 14122Each
147147Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. \na) In exposed surfaces or in trenches. \n(iv) 110 mm x 75mmitem 1428Each
148148b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iv) 110 mm x 75mmitem 14318Each
149149Supplying fiting and fixing PVC reducing Tee of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.\na) In exposed surfaces or in trenches. \n(iii) 110 mm x 75mmitem 14412Each
150150b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.\n(iii) 110 mm x 75mmitem 14510Each
151151Supplying fiting and fixing PVC cleaning pipe of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. \n(b) 110 mmitem 14624Each
152152(c) 75 mmitem 14730Each
153153Providing fitting fixing CI Grating to the floors complete as directed and specified\n(ii) 110 mm dia PVC Cowel ISI makeitem 14828Each
154154Providing fitting fixing CI Grating to the floors complete as directed and specified\n(ii) 75 mm diaitem 14912Each
155155Providing fitting and fixing 450mm dia. 90mm thick C.I. Man hole cover and frame of 58 Kg. weight complete as directed and specified.item 1502each
156156Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.item 15113each
157157Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directeditem 1528Each
158158Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified. \n(A) Exposed or in trenches\nSUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)\nb) 40 mm diaitem 153200RM
159159(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.\nSUPREME/ PRINCE / SFMC / FUSION BAND or other equvalent approved brand (High presure pipe Sch-40)\nc) 32 mm diaitem 154150RM
160160Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured sepaAPWD Rately)\nJaquare make \n(a)Continental /Clarion\n(i)Standarditem 15560Each
161161Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid sepaAPWD Rately) \nJaquar\n(a) Continental / Clarion\n(i)15mm dia Male / Female (long thread)item 15660Each
162162Supplying fitting and fixing Chrome Plated (C.P.) sink cock of approved brand as directed and specified. (G.I. & C.P pipes will be measured and paid sepaAPWD Rately) \nEssco brand\na) Sink cock with \"U\" shape swinging casted spoutitem 1572Each
163163Supplying fitting and fixing Chrome Plated (C.P.) shower 15mm dia. Of approved brand as directed and specified. (Pipes will be measured and paid sepaAPWD Rately)\nEssco make\n(h)Round shower with revolving joint 100mm diaitem 15810Each
164164Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.\nb) 40 mm dia.item 1595Each
165165c) 25 mm dia.item 1606Each
166166d) 2O mm dia.item 1616Each
167167Supplying fitting and fixing gun metal check valve including necessary threads to pipes.\nb) 40 mm dia (Heavy type)item 1623Each
168168Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).item 163150RM
169169Labour for boring hole for inserting tube well pipes through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department.\nvi) Bore hole of 200mm diameteritem 164150RM
170170Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department.\nPVC PIPE\n SUPREME /PRINCE / FUSION /SFMC Brand\nvii) 160mm diameteritem 165150RM
171171Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed.\nA) G.I. pipe\na) TATA / SAIL (Medium)socket should be welded to the pipes.\niv) 50mm diameteritem 166110Rm
172172Supplying fitting and fixing brass Tez filter 2.00 metre long.item 16740Each
173173Supplying fitting and fixing check valve (non return valve) including thread to pipes.\niv) 50mm diameteritem 1684Each
174174Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtaineditem 1691Job
175175Flushing, clearing, washing and watering of the tube wellitem 1701Job
176176Supplying and placing ferrocement water tanks of circular/rectengular shape over stagging with manhole cover with locking and clearing arrangement including providing pads of size as required for inlet and outlet pipes complete as directed.(Stagging should be measured and paid sepaAPWD Rately). \n2000 Lt capacity water tankitem 1714Each
177177Supplying fitting and fixing iron removal filter filling with treated sand, pebbles, manganishdioxide and other required materials of various filtration APWD Rate per hour of DOLPHIN make with all necessary fittings such as valve,bib cock,pipe connection etc.with a free maintanance period of six monthhs\n(A) With Zoloto fittings \n(II) 2000 liters capacity\n(a) 4 mm thick Vesselitem 1721Each
178178For Internal electrificationitem 1731Each
179179For external electrificationitem 1741Each
180180Half Statue of Dr. B.R . Ambedkar (L/S)item 1751Each
181181Furniture (L/S)item 1761Each
182182GSTitem 1771Each
183183Agency Charge (3%)item 1781Each

AI Tender Summary

OUR REF NO 23546884
AUTHORITY Government Departments
TENDER VALUE 1.76 Crore
LAST DATE 15-02-2020
Authority
Authority Name Department of Welfare of Plain Tribes & Backward Classes
Work Description Construction Of Dr . B . R . Ambedkar Bhawan At Gohpur Sub Division
Basic Detail
Tender No SCDC/C/Gohpur/479/2018-19/32
Bidding Type Auction
Location
City Gohpur
State Assam
Key Dates
Publish Date 08 Feb 2020
Submission Date 15 Feb 2020
Open Date 15 Feb 2020
Finance
Tender Value 1.76 Crore
Tender Fee 5500
EMD 88.12 Lakhs
Exemption Not Available
Document List
Tendernotice_1.pdf
39EE7922-8B96-4881-9BB4-A0D01B6BAF69.html
SBD.pdf
BOQ_25029.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 08, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 15, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 15, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

html

39EE7922-8B96-4881-9BB4-A0D01B6BAF69.html

pdf

SBD.pdf

xls

BOQ_25029.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders