}

Repair Rectification Of Of Day To Day Complaints Of External Electrification Supply System Including Repairs To External Electric Supply Including Replacement Of Lt Oh Line , Lt Ug Cables And Repairs To Apfc , Lt Pannel Boards And Connected Misc Works, SECUNDERABAD-Telangana

Military Engineer Services-MES has published Repair Rectification Of Of Day To Day Complaints Of External Electrification Supply System Including Repairs To External Electric Supply Including Replacement Of Lt Oh Line , Lt Ug Cables And Repairs To Apfc , Lt Pannel Boards And Connected Misc Works. Submission Date for this Tender is 26-02-2020. Electrification Work Tenders in SECUNDERABAD Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

23541511
Repair Rectification Of Of Day To Day Complaints Of External Electrification Supply System Including Repairs To External Electric Supply Including Replacement Of Lt Oh Line , Lt Ug Cables And Repairs To Apfc , Lt Pannel Boards And Connected Misc Works
Open Tender
Indian
Telangana
SECUNDERABAD
26-02-2020

Tender Details

Repair Rectification Of Of Day To Day Complaints Of External Electrification Supply System Including Repairs To External Electric Supply Including Replacement Of Lt Oh Line , Lt Ug Cables And Repairs To Apfc , Lt Pannel Boards And Connected Misc Works

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work: REPAIR/RECTIFICATION OF OF DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIFICATION SUPPLY SYSTEM INCLUDING REPAIRS TO EXTERNAL ELECTRIC SUPPLY INCLUDING REPLACEMENT OF LT OH LINE, LT UG CABLES AND REPAIRS TO APFC, LT PANNEL BOARDS AND CONNECTED MISC WORKS IN ZONE II 'B' UNDER AGE E/M NO-II OF GE (UTILITY) SECUNDERABAD.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 M&L for attending, repair and rectification of external LT/HT electric supply complaints on 1100/11000 Volts grade, over head/underground system alongwith necessary T&P, safety devices as per site requirement for the following type of complaints complete all as specified and directed:- BI01010001010000000000000515BI0100001112
2 1.01 Replacement of worn out jumpers, jointing and tightening with new ACSR conductor.\nNote:- Single phase/two wire or 3 phase/4 wire system will be considered as one job for payment purpose. BI01010001010000000000000515BI0100001113 150 Each
3 1.02 Disconnecting from over head conductor, cutting worn out portion of LT cables of any type and size, carry out repairs including taking out cables from under ground loop line and rejoining the same to restore electric supply.\nNote :- (i) LT Jointing Kits, Cable protection Pipe if required at site will be measured and paid separately.\n(ii) Quoted rate is deemed to be inclusive of cutting and removing the pole coping and inserting the cable alongwith protection pipes.\n BI01010001010000000000000515BI0100001114 150 Each
4 1.03 Repair/Replacement of faulty LT switch gear/Main Switch/MCCB's of any type and size fixed in panel board pole mounted boxes on walls or any other indicated places including provision of lugs/thimbles of suitable sizes.\nNote :- Switch gears used for replacement will be issued under relevant items of this schedule.\n BI01010001010000000000000515BI0100001115 50 Each Job
5 1.04 Repair/Replacement of street light timers of any capacity, in any location.\nNote: Spares for repair of Street light timers or New timer switches will be measured and paid separately. BI01010001010000000000000515BI0100001116 25 Each Job
6 1.05 Taking down old unsv Street light fittings in any position of any capacity, Repair of street light fittings by replacement of unsv spares and re-fixing the same in existing location.\nNote:- Spares for repair of street light fittings will be measured and paid under respective items. BI01010001010000000000000515BI0100001117 250 Each Job
7 1.06 Attending KWH meter compliants viz rectifying loose connections in meter and switch gear, cheking of calibration of meter to ensure proper function, testing sealing and submission of reading after repairs to reps of AGE E/M No-II BI01010001010000000000000515BI0100001118 150 Each Job
8 1.07 Repair/replacement of Energy meter of any capacity and any type. BI01010001010000000000000515BI0100001119 20 Qtl
9 1.08 Notes for Item Nos 1.01 to 1.07:-\n(a) The contractor will be alloted complaints at MES complaint cell on required basis on all working days and sufficient resources will be deployed by him/her for completion of day to day comaplaints within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit without intimation of sufficient cause, penalties will be recovered twice of the quoted rate for each un-attended complaint. \n(b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and the same will be updated on daily basis in consulatation with Engr-in-Charge or JE E&M as detailed.\n(c) The contractor will make suitable arrangment for emergency complaints and will notify authorised rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond stated time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard.\n BI01010001010000000000000515BI0100001120
10 1.09 (d) The contractor will intimate MES authority well in advance if electric shutdown is required during rectification of complaints.\n(e) The quoted rate is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station at Secunderabad.\n(f) The contractor will maintain location wise record of each spare utilized as per inventry format given by AGE E/M, Secunderabd and the same shall be submitted to E/M No I store on daily basis. BI01010001010000000000000515BI0100001121
11 2 M&L for ACSR conductor, steel reinforced for LT over head lines on poles including streching tightining of poles insulator with binding wire of suitable size with insulator/streching of ACSR conductor including disconnecting/taking out old existing unsv ACSR conductors complete all as specified and directed. BI01010001010000000000000515BI0100001122 6 Qtl
12 3 M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, including disconnecting/taking out old existing unsv insulators complete all as specified and directed. BI01010001010000000000000515BI0100001123 50 Each
13 4 M&L for Shackle type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of size 100 mm height, 115 mm dia for 1100 Volt grade, section of straps 31x5 mm, including disconnecting/taking out old existing unsv insulators complete all as specified and directed. BI01010001010000000000000515BI0100001124 50 Each
14 5 S&F Stay assembly comprising of 7/10 SWG galvanised MS stranded stay wire of required length, minimum tensile strength 70 Kg/mm (grade-2 quality) fixed to pole with and including FI clamps, bolts, nuts, washers, galvanised steel stay rod 16mm dia 180 cm long bow 400 x 14 mm nuts/bolts, washers, loop type insulator of size 65 x 90 mm vitreous, clearance dia of hole 16mm, stay plate of size 230 x 230 x 6 mm including necessary excavation and earth work PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation and disposal of surplus soil, upto 50m including disconnecting/taking out old existing unsv stay assembly complete all as specified and directed. BI01010001010000000000000515BI0100001125 5 Per set
15 6 S&F of Galvanised steel wire (GI) 4mm dia including disconnecting/taking out old existing unsv GI wire complete all as specified and directed. BI01010001010000000000000515BI0100001126 0.5 Qti
16 7 M/L for cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed. BI01010001010000000000000515BI0100001127 3 Qtl
17 8 S&F Loadline MCCB (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK), Adjustable thermal and fixed magnetic setting of capacity 400 Amps, 4 Pole, 36 KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB complete all as specified and directed. Make : Standard or techno commercial equivalent model in Havells/Benlo/L&T. BI01010001010000000000000515BI0100001128 4 Each
18 9 All as per item No-8 here in before but of capacity 250 Amps, 4 pole, 25 KA BI01010001010000000000000515BI0100001129 4 Each
19 10 All as per item No-8 here in before but of capacity 200 Amps, 4 pole, 25 KA BI01010001010000000000000515BI0100001130 4 Each
20 11 All as per item No-8 here in before but of capacity 160 Amps, 4 pole, 16 KA BI01010001010000000000000515BI0100001131 4 Each
21 12 All as per item No-8 here in before but of capacity 125 Amps, 4 pole, 16 KA BI01010001010000000000000515BI0100001132 2 Each
22 13 All as per item No-8 here in before but of capacity 100 Amps, 4 pole, 16 KA BI01010001010000000000000515BI0100001133 6 Qtl
23 14 All as per item No-8 here in before but of capacity 63 Amps, 4 pole, 16 KA BI01010001010000000000000515BI0100001134 6 Each
24 15 S&F MCB/Isolator, 100 Amps, 4 pole, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.\n BI01010001010000000000000515BI0100001135 10 Each
25 16 All as per item No-15 here in befor but of capacity 63 Amps, 4 pole, 415 Volts with breaking capacity 10KA BI01010001010000000000000515BI0100001136 10 Each
26 17 All as per item No-15 here in befor but of capacity 40 Amps, 4 pole, 415 Volts with breaking capacity 10KA BI01010001010000000000000515BI0100001137 10 Each
27 18 S&F MCB, SP 10-32 Amps, 415 Volts with breaking capacity 10KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.\n BI01010001010000000000000515BI0100001138 25 Each
28 19 Supply and fixing surface mounting analog timer switch 240 Volts, 50 Hz, 16-20 Amps rating (For Street light/High Mast light) fitted inside steel enclosure complete all as specified and directed Make : L&T cat No AUTS01ANA00 or equivalent of Indo Asian/Standard. BI01010001010000000000000515BI0100001139 15 Each
29 20 S&F Timeite distribution boards, Timelite-32A, 3 Pole/230V - Astronomical time switch along with suitable size of box made of sheet 2mm thick size 30x25x15 cm powder coated suitable for fixing at pole including two set of clamps comprising with the following :-\n(i) MCB TPN 32 Amps 10 KA - 01 No. (ii) Timer Analog type suitable for 24 hours operation of street light (iii) Contctor two pole 40 Amps 415 Volt coil operating voltage 230 volt (iv) Auto manual switch 10 Amps, complete all including internl connection done by using suitabale sie of copper wire complete ll as specified and directed. BI01010001010000000000000515BI0100001140 5 Each
30 21 S&F contactor 3 phase 415 volts 50 Hz of ML-2, 32 Amp rating, coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T cat No SS90701 or equivalent of Legrand/Indoasian. BI01010001010000000000000515BI0100001141 5 Each
31 22 S&F contactor 3 phase 415 volts 50 Hz of MNX 32 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T cat No CS94111 or equivalent of Legrand/Indoasian. BI01010001010000000000000515BI0100001142 4 Each
32 23 S&F contactor 3 phase 415 volts 50 Hz of MNX 40 coil voltage 420 volts, fitted inside steel enclosure complete all as specified and directed. Make : L&T cat No CS94190 or equivalent of Legrand/Indoasian. BI01010001010000000000000515BI0100001143 4 Each
33 24 Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed. BI01010001010000000000000515BI0100001144 8 Each
34 25 All as per item No 24 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001145 6 Each
35 26 All as per item No 24 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 185 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001146 4 Each
36 27 All as per item No 24 above but suitable for aluminium conductor cable of size from 240 sqmm, 3.5 Core to 400 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001147 2 Each
37 28 Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for outdoor End termination heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 16 to 50 Sqmm, complete all as specified and directed. BI01010001010000000000000515BI0100001148 5 Each
38 29 All as per item No 28 above but suitable for aluminium conductor cable of size from 70 sqmm, 3.5 Core to 95 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001149 5 Each
39 30 All as per item No 28 above but suitable for aluminium conductor cable of size from 120 sqmm, 3.5 Core to 150 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001150 5 Each
40 31 All as per item No 28 above but suitable for aluminium conductor cable of size from 185 sqmm, 3.5 Core to 400 Sqmm, 3.5 Core BI01010001010000000000000515BI0100001151 5 Each
41 32 Supply and lay cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/duct or fied to wall/passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of the following sizes including disconnnecting/taking out existing unsv/damaged old LT UG cable complete all as specified and directed :-\nNote : Excavation, Retuning, Sand and brick shall be measured and paid separately.\n BI01010001010000000000000515BI0100001152
42 32.01 2 core X 10 Sqmm BI01010001010000000000000515BI0100001153 400 RM
43 32.02 2 Core X 16 Sqmm BI01010001010000000000000515BI0100001154 400 RM
44 32.03 (4 Core X 16 Sqmm BI01010001010000000000000515BI0100001155 550 RM
45 32.04 3.5 Core X 25 Sqmm BI01010001010000000000000515BI0100001156 400 RM
46 32.05 3.5 Core X 35 Sqmm BI01010001010000000000000515BI0100001157 300 RM
47 32.06 3.5 Core X 50 Sqmm BI01010001010000000000000515BI0100001158 300 RM
48 32.07 3.5 Core X 70 Sqmm BI01010001010000000000000515BI0100001159 300 RM
49 32.08 3.5 Core X 95 Sqmm BI01010001010000000000000515BI0100001160 200 RM
50 32.09 3.5 Core X 120 Sqmm BI01010001010000000000000515BI0100001161 100 RM
51 32.1 3.5 Core X 150 Sqmm BI01010001010000000000000515BI0100001162 50 RM
52 32.11 3.5 Core X 185 Sqmm BI01010001010000000000000515BI0100001163 50 RM
53 32.12 3.5 Core X 240 Sqmm BI01010001010000000000000515BI0100001164 50 RM
54 33 Taking down and relaying of existing under ground cable re-using after jointing of streagth through joint Kit of any size, complete all as specified and directed. \nNotes : Excavation, Retuning, Sand and extra brick shall be measured and paid separately.\n BI01010001010000000000000515BI0100001165 800 RM
55 34 Supplying, erecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2" (inch) wide including taking down old unserviceable PCC poles of any type complete all as specified and directed.\nNote: Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this schedule.\n\n BI01010001010000000000000515BI0100001166 10 RM
56 35 Restreching/Restringing, tightening and repair to overhead line ACSR conductor of any size on LT poles including necessary Aluminium binding wire connectors PVC sleeves for jumper, fixing of insulators and prunning of tree complete all as specified and directed. \nNotes: \n(i) The distance between pole to pole in one span (contains 2/4/6 runs) i.e one span will only be considered for payment purpose. \n(ii) No Extra conductor will be measured for binding to insulators / jumpering etc. BI01010001010000000000000515BI0100001167 300 Each span
57 36 Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in Hard / Dense soil complete all as specified and directed.\n BI01010001010000000000000515BI0100001168 1045 Cum
58 37 All as per item No 36 above but depth exc 1.5 mtr but not exc 3 mtr. BI01010001010000000000000515BI0100001169 1 Cum
59 38 Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed. BI01010001010000000000000515BI0100001170 594 Cum
60 39 Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. BI01010001010000000000000515BI0100001171 443 Cum
61 40 M&L filling sand in trenches for sand cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed.\nNote :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment. BI01010001010000000000000515BI0100001172 311 Cum
62 41 Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed. BI01010001010000000000000515BI0100001173 29.2 Per 1000 Nos
63 42 M&L PCC 1:4:8 type D2 using 40 mm graded stone aggregate for filling & foundation of pole & mass complete all as directed BI01010001010000000000000515BI0100001174 0.8 Cum
64 43 M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling & foundation of pole & stay complete all as directed BI01010001010000000000000515BI0100001175 5 Cum
65 44 M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed BI01010001010000000000000515BI0100001176 0.8 Cum
66 45 Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. BI01010001010000000000000515BI0100001177 50 Rm
67 46 M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 100 mm dia with 6 mm thick in any length including jointing materials to carry LT UG cables of size upto 400 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed. BI01010001010000000000000515BI0100001178 24 Rm
68 47 M&L for replacement of broken earth pit made out of PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate, 20 mm thick and earth pit cover made out of RCC 1:2:4 type B1, cover reinforced with 8 mm dia MS deformed bars @ 100 mm centre to centre both ways with hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and including reconnecting of earth lead of any type with new nuts, bolts and washers etc as required at site complete all as specified and directed. BI01010001010000000000000515BI0100001179 10 Each job
69 48 M&L repair/maintenance of stay by tightening of stay wire after untying the conductor spans from the poles to make correct tensions and maintain verticality of poles, including re-jointing the conductors in position with new binding wire complete all as specified and directed. BI01010001010000000000000515BI0100001180 10 Each job
70 49 M&L for painting the existing LT steel poles of 9.0 Mtr long including cross arms, clamps, street light junction boxes etc with 1 coats of aluminium paint including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed. BI01010001010000000000000515BI0100001181 200 Each job
71 50 M&L for Painting the existing LT PCC poles with 1 coats of synthetic enamole base paint including painting of cross arms, clamps, etc with one coat of aluminium paint and providing alternative band of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 metres height , writing of pole numbers in yellow circle15 cm with black paint on poles complete all as specified and directed.\n BI01010001010000000000000515BI0100001182 125 Each job
72 51 M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. \nNote :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade. BI01010001010000000000000515BI0100001183 6 Each job
73 52 Trimming/pruning and removing of tree branches or any other foreign objects from HT/LT over head conductor and clearing the OH Line of any type and size for one span of any length in 2 way /4 way/6 way conductor system. \nNotes: (i) Insulators of any type, connectors and ACSR conductor of any size required at site will be measured and paid separately under relevant item of this schedule. \n(ii) The contractor is responsible for provision of Necessary T & P and safety equipments to complete the job. \n(iii) Quoted rate is deemed to inclusive of Replacement of Insulators, Joining the ACSR Conductor, Jumpering, stringing the ACSR conductor, Fuse wire etc, if damaged during triming of branches. BI01010001010000000000000515BI0100001184 300 Each job
74 53 Cutting unaxious green growth and grass by manual labour or by machine at all 11 KV Electric Installation premisses/around 2/4 Pole structure/along the boundary fencing and removing rubbish from the site of work complete all as specified and directed. BI01010001010000000000000515BI0100001185 1200 Sqm
75 54 S&F new generation energy saving and environmental friendly long life LED street light made up to pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable street light fitting of any type and capacity complete all as specified and directed. Make : Havells cat No : ENDURAPEARLPLUSSL90WLED757SASYTOPC or equivalent model in Philips/Wipro.\nNote : (i) LED's used should be the make of Cree/Osram/Lumilieds/Nitchia.\n(ii) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers.\n(iii) Surge protection of the drive should be 10 KV or equivalent model in Bajaj/Philips or Wipro BI01010001010000000000000515BI0100001186 20 Each job
76 55 All as per item No-54 above but 80 watts. Make : Havells cat No : ENDURAPEARLPLUSSL80WLED757SASYTOPC or equivalent model in Philips/Wipro.\n BI01010001010000000000000515BI0100001187 20 Each
77 56 All as per item No-54 above but 70 watts. Make : Havells cat No : ENDURAPEARLPLUSSL70WLED757SASYTOPC or equivalent model in Philips/Wipro.\n BI01010001010000000000000515BI0100001188 20 Each
78 57 All as per item No-54 above but 60 watts. Make : Havells cat No : ENDURAPEARLPLUSSL60WLED757SASYTOPC or equivalent model in Philips/Wipro. BI01010001010000000000000515BI0100001189 20 Each
79 58 S&F Energy saving, environmental friendly long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 150 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable etc, fixing to wall/pole including taking down old unserviceable light fitting of any type and capacity complete all as specified and directed. Make : Havells cat No : JETAIRISFLS150WLED757PSYMLTG or equivalent model in Philips/Wipro. \nNote : (i) LED's used should be the make of Cree/asram/Lumilieds/widchia \n(ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. \n(iii) Surge protection of the driver should be 10 KV \n BI01010001010000000000000515BI0100001190 10 Each
80 59 S&F New generation, post-top, energy saving, environmental friendly long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, with high power LED as light source of capacity 25 watts and all standard accessories etc fixed to main gate in any location and position complete all as specified and as directed. Make : Havells cat No : RUBYPT25WLED757PSYMTOPC or equivalent model in Philips/Wipro. \nNote : (i) LED's used should be the make of Cree/asram/Lumilieds/widchia \n(ii) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer. \n(iii) Surge protection of the driver should be 10 KV \n BI01010001010000000000000515BI0100001191 10 Each
81 60 S&F LED Driver suitable for upto 45 watts LED light fittings complete all as specified and directed. Make : Bajaj cat part No BGD 70 065 5Y or techno commercial equivalent model in Philips/Wipro/Havells. BI01010001010000000000000515BI0100001192 15 Each
82 61 S&F LED Driver suitable for upto 60 watts LED light fittings complete all as specified and directed. Make : Bajaj cat part No BGD 36 185 5Y or techno commercial equivalent model in Philips/Wipro/Havells. BI01010001010000000000000515BI0100001193 15 Each
83 62 S&F LED Driver suitable for upto 72 watts LED light fittings complete all as specified and directed. Make : Bajaj cat part No BGD 36 180 5Y or techno commercial equivalent model in Philips/Wipro/Havells. BI01010001010000000000000515BI0100001194 15 Each
84 63 S&F LED Driver suitable for upto 90 watts LED light fittings complete all as specified and directed. Make : Bajaj cat part No BGD 66 140 5Yor techno commercial equivalent model in Philips/Wipro/Havells. BI01010001010000000000000515BI0100001195 15 Each
85 64 Supply and fixing steel light bracket made out of 40 mm bore mild steel GI light grade tubing over all length 1.5 mtr bend to shape as directed including providing two Nos MS flat iron 40x6 mm clamp of appropriate size with nut bolts and washer duly painted with two coat of synthetic enamel paint over a coat of primer (GI surface shall not be painted) complete all as specified. BI01010001010000000000000515BI0100001196 20 Each
86 65 S&F PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed. Make : Richa/havells or equivalent. BI01010001010000000000000515BI0100001197 5 Each
87 66 All as per item No-65 above but of size 6 Sqmm complete all as specified and directed. BI01010001010000000000000515BI0100001198 5 Each
88 67 S&F street light LT junction box out door type, testing and commissioning with locking arrangements fixed on poles PVC Moulded of size 230x180x110 mm alongwith Bus Bar, 20 to 32 A MCB SPN - 01 Nos for connecting suitable size of XLPE UG cable all as specified and directed. BI01010001010000000000000515BI0100001199 20 Each
89 68 Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.\nMake : TATA/Jindal/Bansal with ISI marked. BI01010001010000000000000515BI0100001200 24 Each
90 69 Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.\nMake : TATA/Jindal/Bansal with ISI marked. BI01010001010000000000000515BI0100001201 24 Each
91 70 Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.\nMake : TATA/Jindal/Bansal with ISI marked. BI01010001010000000000000515BI0100001202 18 Rm
92 71 S&F LT line rigid PVC Spacers spiral type, two lines, Phase to phase distance 300 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm. BI01010001010000000000000515BI0100001203 150 Each
93 72 S&F LT line rigid PVC Spacers spiral type, three lines, Phase to phase distance 600 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm. BI01010001010000000000000515BI0100001204 150 Each
94 73 S&F LT line rigid PVC Spacers spiral type, four lines, Phase to phase distance 900 mm, spacer rod dia 13 mm, spiral hole dia 5-6 mm and spiral length 250 mm. BI01010001010000000000000515BI0100001205 150 Each
95 74 S&F On-Load changeover switch (In sheet steel enclosure), AC 21 (Side Handle), 4 pole of capacity 400 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. Make : Standard or techno commercial equivalent dolel in Havells/Benlo/L&T BI01010001010000000000000515BI0100001206 1 Each
96 75 S&F On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 100 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. Make : Standard or techno commercial equivalent dolel in Havells/Benlo/L&T BI01010001010000000000000515BI0100001207 2 Each
97 76 S&F On-Load changeover switch (In sheet steel enclosure), AC 23 (Side Handle), 4 pole of capacity 63 Amps, 415 Volts, 50 Hz, Conforms to HSN Code : 8536 complete all as specified and directed. Make : Standard or techno commercial equivalent dolel in Havells/Benlo/L&T BI01010001010000000000000515BI0100001208 2 Each
98 77 Supply only of aluminium cable lugs of following sizes :- BI01010001010000000000000515BI0100001209
99 77.01 16 Sqmm Size BI01010001010000000000000515BI0100001210 30 Each
100 77.02 25 Sqmm size BI01010001010000000000000515BI0100001211 30 Each
101 77.03 35 Sqmm size BI01010001010000000000000515BI0100001212 30 Each
102 77.04 50 Sqmm size BI01010001010000000000000515BI0100001213 30 Each
103 77.05 70 Sqmm size BI01010001010000000000000515BI0100001214 20 Each
104 77.06 95 Sqmm size BI01010001010000000000000515BI0100001215 20 Each
105 77.07 120 Sqmm size BI01010001010000000000000515BI0100001216 20 Each
106 77.08 150 Sqmm size BI01010001010000000000000515BI0100001217 20 Each
107 77.09 185 Sqmm size BI01010001010000000000000515BI0100001218 20 Each
108 77.1 240 to 400 Sqmm\nMake for ser No 77.01 to 77.10 : Dowells/Jaison. BI01010001010000000000000515BI0100001219 20 Each
109 78 Supply only of insulation tap roll for cable protection of following sizes :- BI01010001010000000000000515BI0100001220
110 78.01 25 mm Size of 100 RM length BI01010001010000000000000515BI0100001221 150 Each
111 78.02 15 mm Size of 100 RM length BI01010001010000000000000515BI0100001222 150 Each
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail