| Name of Work: Dalkhola Fire Station - Repairing and Renovation Works under Uttar Dinajpur Division, PWD, during the year 2019-20. | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1 | CIVIL WORKS_______________________________________________________ Anti-termite treatment- | |||
| 2 | 1.01 | Anti - termite treatment to the junction of wood work and masonry walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates(1% concentration) with water by weight including spraying at the points of contact with the adjoining masonry by drilling 6m. dia holes at a downward angle of about 45 degree at the junction of woodwork and masonry and squirting chemical emulsion into these holes at the rate of half litre per hole. The entire work is to be carried out as per specification of Code I.S.-6313 (Part-III)-1981. The shutters are to be sprayed with emulsion.on both sides. All wooden fixtures like almirahs, racks etc.are also to be throughly sprayed with chemical emulsion.(Payment will be made on the basis of outside measurements of doors and windows.) | 19.2 | Sqm. | |
| 3 | 2 | Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75 m as directed. | 222.3 | Sqm. | |
| 4 | 3 | Ordinary cement concrete (mix 1:1.5:3) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant codes. | |||
| 5 | 3.01 | With Pakur Variety stone chips. | 352.7 | Cum. | |
| 6 | 4 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).\nUsing grey cement & Pakur veriety stone chips. | |||
| 7 | 4.01 | 35 mm. thick | 33.84 | Sqm. | |
| 8 | 5 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface. | 50 | Sqm. | |
| 9 | 6 | Cement concrete with graded stone ballast (40 mm size) excluding shuttering.\nIn ground floor. | |||
| 10 | 6.01 | With PAKUR Variety stone material. | |||
| 11 | 6.02 | 1:3:6 proportion. | 9.54 | Cum. | |
| 12 | 7 | Hire and labour charge for shuttering with centreing and necessary staging upto 4 m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams,columns, lintels curved or staight including fitting fixing and striking out after complection of works. (upto roof of ground floor). | |||
| 13 | 7.01 | Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work | |||
| 14 | 7.02 | In Ground Floor | 66.47 | Sqm. | |
| 15 | 7.03 | In 1st Floor | 6.25 | Sqm. | |
| 16 | 8 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. | |||
| 17 | 8.01 | For works in foundation, basement and upto roof of ground floor/upto 4m. | |||
| 18 | 8.02 | With JSW/SSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL steel. | |||
| 19 | 8.03 | In Ground Floor | 6.62 | MT | |
| 20 | 9 | Brick work with 1st class bricks in cement mortar (1:4). | |||
| 21 | 9.01 | In superstructure | |||
| 22 | 9.02 | In Ground Floor | 0.75 | Cum. | |
| 23 | 9.03 | In 1st Floor | 0.75 | Cum. | |
| 24 | 10 | Brick work with 1st class bricks in cement mortar (1:6). | |||
| 25 | 10.01 | In foundation and plinth. | 3.5 | Cum. | |
| 26 | 11 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. | |||
| 27 | 11.01 | In Ground Floor | 5 | Sqm. | |
| 28 | 11.02 | In 1st Floor | 5 | Sqm. | |
| 29 | 12 | Supplying , and laying true to line and level vitrified tiles of approved brand (size not less than 600mm x 600mm x 10mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2mm thick cement slurry back side of tiles using cement @ 2.91 kg./ M2 or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor / moasic etc without any backing course ) laid after applications slorry using 1.75 kg of cement per M2 below morter only, joints grouted admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the coat of materials, labour and all other incidential charges complete true to the menufacture's specification and direction of engineering- in -charge . ( White cement, synthetic adhesive and grout material to be supplied by the contractor). | |||
| 30 | 12.01 | With application slurry @ 1.75 kg/ sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ sq.m white cement for joint filling with pigment. | |||
| 31 | 12.02 | Light Colour | |||
| 32 | 12.03 | In Ground Floor | 176 | Sqm. | |
| 33 | 12.04 | In 1st Floor | 144.6 | Sqm. | |
| 34 | 13 | Supplying,Fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. | |||
| 35 | 13.01 | Floor \nWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20 Kg/Sq.m. | |||
| 36 | 13.02 | Area of each tile the above 0.09 Sq.m. | |||
| 37 | 13.03 | Coloured decorative. | |||
| 38 | 13.04 | In Ground Floor | 21.6 | Sqm. | |
| 39 | 13.05 | In 1st Floor | 34.4 | Sqm. | |
| 40 | 13.06 | Wall \nWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @\n0.20kg/Sq.m. | |||
| 41 | 13.07 | Area of each tile the above 0.09 Sq.m. | |||
| 42 | 13.08 | Coloured decorative. | |||
| 43 | 13.09 | In Ground Floor | 54 | Sqm. | |
| 44 | 13.1 | In 1st Floor | 90 | Sqm. | |
| 45 | 14 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame excluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be corrected upto three decimals). | |||
| 46 | 14.01 | Sal : Local. | |||
| 47 | 14.02 | In Ground Floor | 0.16 | Cum. | |
| 48 | 14.03 | In 1st Floor | 0.16 | Cum. | |
| 49 | 15 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar , end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction . ( cost of concrete will be paid separately). | |||
| 50 | 15.01 | 40mm x 6mm, 250mm Length . | 60 | Each | |
| 51 | 16 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. | |||
| 52 | 16.01 | 100 mm x 58 mm x 1.90 mm. | 60 | Each | |
| 53 | 17 | Brass floor door stopper. | 10 | Each | |
| 54 | 18 | Brass hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. | |||
| 55 | 18.01 | 300mm long. | 10 | Each | |
| 56 | 19 | Anodise aluminium barred/tower/socket bolt (full covered) of approved manufactured from extruded section conforming to I.S.204/74 fitted and Fixed with cadmium plated screws:. | |||
| 57 | 19.01 | 300mm long x 10mm dia. bolt. | 10 | Each | |
| 58 | 20 | Anodised aluminium butt hinges of approved quality manufactured from extruded section conforming to I.S. specification (I.S.205/66) and fitted and fixed with cadmium plated screws:. | |||
| 59 | 20.01 | 75 x 63 x 3.2 mm. | 20 | Each | |
| 60 | 21 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S.230/72) fitted and fixed complete:. | |||
| 61 | 21.01 | With continuous plate base (hexagonal/round rod). | |||
| 62 | 21.02 | 150 mm grip x 12 mm dia rod. | 10 | Each | |
| 63 | 22 | Supplying, Fitting & Fixing Factory made prelaminated P.V.C. door frame of size 50 mm x 47 mm with a wall thickness of 5 mm, made out of extruded 5 mmPrelaminated PVC sheet miter cut at two corners and joined with two nos of 1.5mm long brackets of 15 mm x 15 mm M.S. square tube. The two vertical doorprofiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge,weather seal to be provided through out the frame. The door frame shall be fixedwith the wall using 65/100 mm M.S. Screws hrough the frame by using P.V.Cfasteners. A minimum of 4 Nos of screws to be provided for each vertical memberand minimum 2 Nos for horizontal member etc. complete as per anufacturer?sspecification and direction of Engineer-in-Charge. | 10 | M | |
| 64 | 23 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thicknessand size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have costof steel primers of approved make and manufacture, M.S. frame covered with 5mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out ofwhich 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle oneither sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock railsshall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm widecross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th.both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles&rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner sideand joined together with solvent cement adhesive. An additional 5 mm th. PVCstrip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as perdirection of Engineer-in-Charge. | 5.04 | Sqm. | |
| 65 | 24 | Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor).[Excluding cost of chipping over concrete surface]. | |||
| 66 | 24.01 | With 1:4 cement mortar . | |||
| 67 | 24.02 | 20 mm.thick plaster. | |||
| 68 | 24.03 | In Ground Floor | 110.4 | Sqm. | |
| 69 | 24.04 | In 1st Floor | 111.9 | Sqm. | |
| 70 | 25 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain.\nNOTE:- Cement 0.152 cu.m. per 100 sq.m. | 67.2 | Sqm. | |
| 71 | 26 | Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. | |||
| 72 | 26.01 | Two Coats | |||
| 73 | 26.02 | In Ground Floor | 638.6 | %Sqm. | |
| 74 | 26.03 | In 1st Floor | 156 | %Sqm. | |
| 75 | 26.04 | In Mumty Room | 42 | %Sqm. | |
| 76 | 27 | Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) | |||
| 77 | 27.01 | Two Coats | |||
| 78 | 27.02 | Solvent based interior grade Acrylic Primer | 1342 | %Sqm. | |
| 79 | 28 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. \nIn Ground floor (Two Coat) | |||
| 80 | 28.01 | Premium 100% Acrylic Emulsion | |||
| 81 | 28.02 | In Ground Floor | 638.6 | Sqm. | |
| 82 | 28.03 | In 1st Floor | 156 | Sqm. | |
| 83 | 28.04 | In Mumty Room | 42 | Sqm. | |
| 84 | 29 | Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) sq.m | |||
| 85 | 29.01 | In Ground Floor | 1498 | Sqm. | |
| 86 | 29.02 | In 1st Floor | 156 | Sqm. | |
| 87 | 29.03 | In Mumty Room | 42 | Sqm. | |
| 88 | 29.04 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. | 90 | Sqm. | |
| 89 | 30 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary. | |||
| 90 | 30.01 | On timber or plastered surface: | |||
| 91 | 30.02 | With super gloss (hi-gloss). | |||
| 92 | 30.03 | Two coats (with any shade except white). | 150.3 | Sqm. | |
| 93 | 30.04 | On steel or other metal surface: | |||
| 94 | 30.05 | With super gloss (hi-gloss). | |||
| 95 | 30.06 | Two coats (with any shade except white). | 143.49 | Sqm. | |
| 96 | 31 | Applying acrylic emulsion paint of approved make and brand on walls and ceiling including sand papering in intermediated coats including putty ( to be done under specific instructions of superintending engineer):\n(two coats). | |||
| 97 | 31.01 | With Luxury quality. | 1342 | Sqm. | |
| 98 | 32 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. and cutting trenches in any soil through masoury concrete structures etc. if necessary and mending good damages including jointing with jointing materials (Spun yarn, valamoid / bitumen/M.seal etc) complete. | |||
| 99 | 32.01 | UPVC PIPES. | |||
| 100 | 32.02 | 110 mm. Dia. | 22 | M | |
| 101 | 32.03 | UPVC fitting:. | |||
| 102 | 32.04 | Shoe. | |||
| 103 | 32.05 | 110 mm. Dia. | 10 | Each | |
| 104 | 33 | Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white. | |||
| 105 | 33.01 | In 10-12 Micron thickness Annodizing film. | |||
| 106 | 33.02 | Natural White. | |||
| 107 | 33.03 | For 2-Track window | 203.78 | Kg. | |
| 108 | 34 | Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work). | |||
| 109 | 34.01 | In 10-12 Micron thickness Annodizing film. | |||
| 110 | 34.02 | Natural white | |||
| 111 | 34.03 | Louvered window. | |||
| 112 | 34.04 | Top , bottom and side member. | 8 | M | |
| 113 | 34.05 | Louver section. | 5 | M | |
| 114 | 35 | Labour charge for fabrication and installation of composite door, window, partitions made from annodized extruded alloy aluminium section for the following units:- | |||
| 115 | 35.01 | Glazed aluminium sliding windows made of extruded and anodized alloy aluminium sectios , fabrications, including cutting to proper shape and size, drilling and alinging of window and shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joinerires along with extruded neoprine or EPDM gasketing in between window frame and masonary work (walls, column, beam, lintels etc.), as well as between glass and shutter frame for fixing glass, & poly sulphate sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate incluides the hire charges of all tools and plants, including all incidental charges, adhesive, joineries such as screw, cleat angle etc. But excludes the cost of extuded aluminium sections, glass, neoprene /EPDM gasketing, locking arrangement and rollers. | |||
| 116 | 35.02 | Louvered window. | |||
| 117 | 35.03 | In Ground Floor | 1.8 | Sqm. | |
| 118 | 35.04 | In 1st Floor | 1.2 | Sqm. | |
| 119 | 36 | Supplying bubble free float glass of approved make and brand. Conforming to IS: 2835-1987.\n | |||
| 120 | 36.01 | 5mm thick coloured / tinted / smoke glass. | 57 | Sqm. | |
| 121 | 37 | Supplying Alluminium casted body butt hinge ( KOBRA type ) (Natural white). | 50 | Each | |
| 122 | 38 | Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofingproperties by mixing with water in proportion (1 onding agent: 4 water : 6 cement) as per Manufacturer's specification. | 297 | Sqm. | |
| 123 | 39 | Extra rate for using water proofing and plasticising admixture @ 0.2% by weight of cement (or at manufacturer's specified rate) for concrete of various grades. | 15 | Kg. | |
| 124 | 40 | Supplying & laying 3mm thick pre-fabricated plastomeric water proofingmembrane conforming to EN 12311-1 & ASTMD 5147, manufactured withatactic poly propylene (APP) modified premium grade asphalt, speciallyreinforced with non-woven polyester core with polyester reinforcement @160gms per sqm & both faces covered with thermo-usible polyethylene film/MineraL on top face over a coat of primer @ 0.40 lit/sqm of manufacturer'sspecification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transversedirection and fused using LPG/ Propane torch employing extra care ensuringfull bondage,complete removal of entrapped air and sealing edges intogrooves in appropriate manner as per direction of Engineer -in-charge allcomplete including materials,labour and applicable axes. (Payment shall bemade on the basis of finished surface area.).Membrane Property: Softening Point > 150 deg C, ColdFlexibility < -6 deg C, Tensile Strength, N/cm : 600 (longitudinal), 450 (transverse), Tearing Strength, N:300 (longitudinal), 200 (transverse). | 297 | Sqm. | |
| 125 | 41 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m. | |||
| 126 | 41.01 | In ground floor including roof | 16 | Cum. | |
| 127 | 42 | Dismantling all types of plain cement concreteworks, stacking serviceable materials at site andremoving rubbish as directed within a lead of 75m. | |||
| 128 | 42.01 | Upto 150 mm. thick | |||
| 129 | 42.02 | In ground floor including roof | 2.25 | Cum. | |
| 130 | 43 | Dismantling artificial stone flooring upto 50 mm.thick by carefully chiselling without damaging thebase and removing rubbish as directed within alead of 75 m | |||
| 131 | 43.01 | In ground floor including roof | 24 | Cum. | |
| 132 | 44 | Removal of rubbish,earth etc. from the workingsite and disposal of the same beyond thecompound, in conformity with the Municipal /Corporation Rules for such disposal, loading intotruck and cleaning the site in all respect as perdirection of Engineer in charge. | 34.6 | Cum. | |
| 133 | 45 | M.S. works in framed gratings etc. made of round or square bars and frame work or M.S. flats | 0.6 | Qtl. | |
| 134 | 46 | Supplying 1.5 mm thick M.S. sheet fitted and fixed on one or both faces of m.s./w.i. gate etc. | 10.08 | Sqm. | |
| 135 | 47 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting anderection all complete.The rate includes the cost of all M.S. Hollow section, allconsumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental charges (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code infinished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. | |||
| 136 | 47.01 | Span up to 12 Mtr.- For Roof Truss works. | 1.18 | MT | |
| 137 | 48 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables suchas electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. | |||
| 138 | 48.01 | For trusses spanning up to 12.00 m | 0.98 | MT | |
| 139 | 49 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lapand one corrugation minimum side lap. (Payment to be madeon area of finished work). | |||
| 140 | 49.01 | In Roof:- With 0.5 mm thick sheet | 150 | Sqm. | |
| 141 | 50 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia etc.with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. Area of each Granite slab = 0.6 square metre. ite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] | 8 | Sqm. | |
| 142 | 51 | SANITARY & PLUMBING WORKS_______________________________ Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. Complete in all respect including cost of all necessary fittings as required, jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) | |||
| 143 | 51.01 | For Exposed Work PVC Pipes | |||
| 144 | 51.02 | 15 mm dia. | 66.1 | M | |
| 145 | 51.03 | 20 mm dia. | 36 | M | |
| 146 | 51.04 | 32 mm dia. | 46 | M | |
| 147 | 52 | Supplying, fitting and fixing shower of approved brand and make. | |||
| 148 | 52.01 | Chromium plated round shower with revolving joint 100 mm diawith rubid cleaning system (Equivalent to Code No. 542(N) & Model -Tropical / Sumthing Special of ESSCO or similar brand). | 5 | Each | |
| 149 | 52.02 | Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook (Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). | 5 | Each | |
| 150 | 53 | Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). | |||
| 151 | 53.01 | 50 mm. | 1 | Each | |
| 152 | 53.02 | 40 mm. | 1 | Each | |
| 153 | 53.03 | 32 mm. | 1 | Each | |
| 154 | 53.04 | 25 mm. | 1 | Each | |
| 155 | 54 | Supplying, fitting and fixing bib cock or stop cock. | |||
| 156 | 54.01 | Chromium plated Bib Cock (angular shape with wall flange) (Equivalent to Code No. 5037 & Model - Florentine of Jaquar or similar brand). | 6 | Each | |
| 157 | 54.02 | Chromium plated concealed Stop Cock heavy duty (Equivalent to Code No. 5083 & Model - Florentine of Jaquar or similar brand). | 10 | Each | |
| 158 | 55 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. | |||
| 159 | 55.01 | Sink with drain board 1050 mm X 450 mm X 180 mm | 1 | Each | |
| 160 | 56 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. brackets including two coats of painting to bracket etc. | 2 | Each | |
| 161 | 57 | Supplying PVC water storage tank of approved quality with closed top weith lid (Black) - Multilayer. | |||
| 162 | 57.01 | 1000 litre capacity | 2 | Each | |
| 163 | 58 | Labour for hoisting plastic water storage tank. | |||
| 164 | 58.01 | Upto 1500 litre capacity. | |||
| 165 | 58.02 | Extra for each additional storey. | |||
| 166 | 58.03 | Upto 3rd storey from G.L. | |||
| 167 | 58.04 | Extra for each additional storey | 2 | Each | |
| 168 | 59 | Supplying, fitting and fixing pillar cock of approved make. | |||
| 169 | 59.01 | CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model -Tropical / Sumthing Special of ESSCO or similar brand). | 5 | Each | |
| 170 | 59.02 | CP Sink Cock with Regular Swinging Spout (Table Mounted Model) (Equivalent to Code No. 5357 of JAQUAR or similar brand). | 1 | Each | |
| 171 | 60 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. Brackets on 75 mm X 75mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia, approved quality P.V.C.waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. | |||
| 172 | 60.01 | 630 mm X 450 mm size | 5 | Each | |
| 173 | 61 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) | 5 | Each | |
| 174 | 62 | Supplying, fitting & fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P.nut, 15mm dia. | |||
| 175 | 62.01 | 600 mm long | 7 | Each | |
| 176 | 63 | Supplying, fitting and fixing towel rail with two brackets. | |||
| 177 | 63.01 | C.P. over brass. | |||
| 178 | 63.02 | 25 mm dia. and 750 mm long. | 5 | Each | |
| 179 | 64 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding 'P' or 'S' trap (excluding cost of concrete for fixing). | |||
| 180 | 64.01 | 580 mm X 440 mm | 2 | Each | |
| 181 | 65 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 | |||
| 182 | 65.01 | Double Socketed 3 Meter Length | |||
| 183 | 65.02 | 160 mm. | 30 | M | |
| 184 | 65.03 | 75 mm. | 30 | M | |
| 185 | 65.04 | Fittings. | |||
| 186 | 65.05 | Coupler. | |||
| 187 | 65.06 | 75 mm. | 5 | Each | |
| 188 | 65.07 | 160 mm. | 5 | Each | |
| 189 | 65.08 | Plain Tee | |||
| 190 | 65.09 | 75 mm. | 2 | Each | |
| 191 | 65.1 | 160 mm. | 2 | Each | |
| 192 | 65.11 | Door Tee. | |||
| 193 | 65.12 | 75 mm. | 2 | Each | |
| 194 | 65.13 | 160 mm. | 2 | Each | |
| 195 | 65.14 | Vent Cowl. | |||
| 196 | 65.15 | 75 mm. | 2 | Each | |
| 197 | 65.16 | 160 mm. | 2 | Each | |
| 198 | 65.17 | Bend 45º | |||
| 199 | 65.18 | 75 mm. | 2 | Each | |
| 200 | 65.19 | 160 mm. | 2 | Each | |
| 201 | 65.2 | Bend 87.5º | |||
| 202 | 65.21 | 75 mm. | 2 | Each | |
| 203 | 65.22 | 160 mm. | 2 | Each | |
| 204 | 65.23 | Pipe Clip. | |||
| 205 | 65.24 | 75 mm. | 15 | Each | |
| 206 | 65.25 | 160 mm. | 10 | Each | |
| 207 | 65.26 | W.C. Connector (150 mm long) 125 X 110(W/WC Ring) | |||
| 208 | 65.27 | 75 mm. | 5 | Each | |
| 209 | 65.28 | Rubber Ring. | |||
| 210 | 65.29 | 75 mm. | 10 | Each | |
| 211 | 65.3 | 160 mm. | 10 | Each | |
| 212 | 65.31 | Passover | |||
| 213 | 65.32 | 110 mm. | 2 | Each | |
| 214 | 65.33 | Multi Floor Trap without Top tile & Strainer | |||
| 215 | 65.34 | 75 mm. | 7 | Each | |
| 216 | 65.35 | Reducing Door Tee 160 X 110 mm | |||
| 217 | 65.36 | 75 mm. | 9 | Each | |
| 218 | 65.37 | Rubber Lubricant. 500 ML. | 5 | Each | |
| 219 | 65.38 | Solvent Cement. 250 ML. | 5 | Each | |
| 220 | 66 | Supplying, fitting and fixing 32 mm dia. flush pipe of approved make with necessary fixing materials and clamps complete. | |||
| 221 | 66.01 | Polythene Flush Pipe. | 6 | Each | |
| 222 | 67 | Supplying, fitting and fixing glass shelf with aluminium guard rails. | |||
| 223 | 67.01 | Ordinary type with 5.5 mm sheet glass. | |||
| 224 | 67.02 | 450 mm X 125 mm. | 5 | Each | |
| 225 | 68 | Supplying, fitting and fixing soap holder. | |||
| 226 | 68.01 | PTMT (Prayag or equivalent). | 5 | Each | |
| 227 | 69 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm | 5 | Each | |
| 228 | 70 | Supplying, fitting and fixing liquid soap container. | |||
| 229 | 70.01 | Cromium plated. | 5 | Each | |
| 230 | 71 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work(6:1) band all round and cement brick work(6:1) upto 0.90 metre from top with 19 mm thick cement plastering(4:1) to inside face upto the depth of cement brick work, 12 mm thick cement plaster(4:1) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal(50 mm to 63 mm size) including R.C.C. cover slab of designed thickness with cement concrete(4:2:1) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making necessary arrangements for pipe conections, excavation of well including shoring, dewatering and remeving the excess earth from the premisis as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00 m. inside dia.\nWith JSW/JSPL/SHYAM/SRMB/BMASL/ELECTROSTEEL/SSL steel & Pakur Variety stone chips. | 3 | Each | |
| 231 | 72 | Picking up and removing old bituminous layer orsand sealing coat from old black topped surfaceand cleaning the exposed surface by scraping andstacking the material as directed. | |||
| 232 | 72.01 | By mechanical means : | |||
| 233 | 72.02 | From 25 mm to 50 mm thick. | 1303 | Sqm. | |
| 234 | 73 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65 mm wide each and the entire frame fitted with 37.5 mm wide battens places both way sin order to make the door of solid core and internal lipping with Garjan orsimilar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. | |||
| 235 | 73.01 | 32 mm thick shutters (single leaf) | 12.6 | Sqm. | |
| 236 | 74 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.In ground floor.(In case of non-supply of single plank, penal rate of reduction of 20% will be made) | |||
| 237 | 74.01 | 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. | |||
| 238 | 74.02 | Ordinary Teak Wood. | 6.3 | Sqm. | |
| 239 | 75 | French polishing to wood work including preparing surface (ordinary gloss) | |||
| 240 | 75.01 | On new wood work | 22.68 | Sqm. | |
| 241 | 76 | ELECTRICAL WORKS_____________________________________________ DISTRIBUTION WIRING- Distn. wiring in 22/1.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in I 9 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand arproved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. \n2 x 22/0.3 (Ph. & N)and 1 x 22/0.3 as ECC | |||
| 242 | 76.01 | Average run 9 mtr. | 120 | Pt. | |
| 243 | 77 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish \n2 x 22/0.3 (Ph. & N)and 1 x 22/0.3 as ECC | |||
| 244 | 77.01 | On Board | 15 | Pt. | |
| 245 | 77.02 | Average run 1.5 mtr. | 10 | Pt. | |
| 246 | 78 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulaled & unsbeathed single core stranded copper wire (Brand approved bv EIC) of the followling sizes through 25mm/ 19 mm bore 3 mm thick polythene pipe and by the GI fish wire and making necy. connection as required as per direction of EIC. Make KEI/Polycab | |||
| 247 | 78.01 | 4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC (Busbar to Main Switch) | 50 | RM | |
| 248 | 78.02 | 2 x 6 sqmm + 1 x 4 sqmm ECC (Panel to TPNDB to SPNDB) | 200 | RM | |
| 249 | 78.03 | 2 x 4 sqmm + 1 x 2.5 sqmm ECC (TPNDB to 2/5-15 A-combo, 4/5-15 A combo, AC) | 200 | RM | |
| 250 | 78.04 | 2 x 2.5 sqmm + 1 x 1.5 sqmm ECC (Composite board & P.P 15A) | 200 | RM | |
| 251 | 78.05 | 3 x 22/0.3 (1.5 sqmm) (for Bulk Head and Inverter connection) | 250 | RM | |
| 252 | 79 | BDB, PDB, ETC- Supplying and fixing 415V, 16-32A per way, double door Horizontal TPN MCB Distribution board wilh IP-42/43 protection,with 4 pole isolator as incomer and SPMCB's ('C' curve,10kA) as outgoing consealed in wall after cutting the wall & mending good the damages 10 origjnal finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/Schneider/Siemens)\n6 way, 63A FP isolator, 18 nos. SPMCB's as outgoing | |||
| 253 | 79.01 | 6 way TPN MCB DB (Legrand/Schneider/Siemens) | 2 | Set | |
| 254 | 80 | Supplying and fixing double-door SPN MCB Distribution Board wiith lP-42/43 protection, with DP isolalors as incomer and SPMCB('C' Curve 10KA) as outgoing,fixing at flat iron frame on wall & mending good the damages to original finish; inter connection wiih suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB)\ni) (2+8)Way-with S&F 240V 40Amps DPMCB isolaror as incomer and 240V 6- 32A SPMCB of breaking capacity 10 KA & C characteristics 8 nos as outgoing\nii) (2+12)way,with S&F 240V 40Amps DPMCB isolator as incomer and 240V 6-32A SPMCB of Breaking capacity l0KA & C characteristics 12 nos as outgoing | |||
| 255 | 80.01 | 2 + 8 Way SPN MCB DB (Legrand/Schneider/Siemens) | 4 | Set | |
| 256 | 80.02 | 2 + 12 Way SPN MCB DB (Legrand/Schneider/Siemens) | 2 | Set | |
| 257 | 81 | CONTROL PANEL- Supply, Installation, Testing & Commissioning of Cubical type panel, compartmentlized floor mounted, indoor type dust and vermin proof powder coated panel board, suitable for 415V 3 phase, 4 wire, 50 HZ, ac supply of suitable size made out of 2 mm thick MS sheet so as accommodate the following mounting complete with copper busbar of 600A capacity, detachable gland plate, with suitabl size 4 mm thick MS channel frame at the bottom, with adequate size 16 sq mm, 25 sqmm, 50 sqmm cu wire, copper bar, cu link cable connector etc along with necy nuts, bolts, clamps, grouting bolts incl providing and fixing the following accessories etc complete as required (all make L&T). | 1 | Item | |
| 258 | 81.01 | INCOMING- 200A rating 415V, TPN SFU with HRC fuse………….1 No. (Incommer) | |||
| 259 | 81.02 | 200A rating 415V, on load change over………….1 No. | |||
| 260 | 81.03 | BUS BAR CHAMBER- 415A, 415V; 4 bar copper busbar………….01 No. | |||
| 261 | 81.04 | OUTGOING- 100A rating 415V, TPN SFU with HRC fuse………….Nos. (01 for Busbar) | |||
| 262 | 81.05 | 63A rating 415V, TPN SFU with HRC fuse…………. 5 Nos. (for Ground Floor TPN DB one spare) | |||
| 263 | 81.06 | 32 A rating 415V, TPN SFU with HRC fuse…………. 4 Nos. (for 2 pump one compound light one spare) | |||
| 264 | 81.07 | ACCESSORIES- 0-300 Amp digital Ammeter with Selector Switch with CT ratio 300/5Amp (Kappa make) --------- 1 set | |||
| 265 | 81.08 | 0-500 V digital voltmeter -------------------------- 1 set | |||
| 266 | 81.09 | LED indication lamp with fuse base & HRC fuse ------------ 3nos. | |||
| 267 | 81.1 | Danger Notice Board--------------------------- 01 No. | |||
| 268 | 81.11 | INTERCONNECTION- Inter connection rto be made through suitable size thoat box/ cable end box (16 SWG) incl. S&F the same with 70 sq. mm. starnded flex copper cable in between 200 Amp main switch to bus-bar, 50 sq. mm. starnded flex copper cable in between bus-bar & 200 Amp main switches, 25 sq. mm. starnded flex copper cable in between bus-bar & 32 Amp main switches & 1.5 sq. mm. copper socketing & tapping. | |||
| 269 | 82 | PLUG & SOCKET- Supply & fixing 240 V, 6-16 A combo 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | |||
| 270 | 82.01 | (Power Point Sep 15/20A) | 7 | Each | |
| 271 | 83 | Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | |||
| 272 | 83.01 | Computer Board | 7 | Each | |
| 273 | 84 | S & F of 240 v 25 Amp 3 pin modular type plug socket (as per E.I.C) without plug top & switch with 2 module GI modular type switch board with top cover plate of flashed in wall & making necy connec.connection with pvc copper wire & earth continuty wire etc. (For AC ) | 2 | Each | |
| 274 | 85 | Supply & Fixing 240 V, 25 A OLP Modular type starter (Brand approved by EIC)and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.. (Make: Legrand /L&T/ Hager/Electron) | 2 | Each | |
| 275 | 86 | Supply & Fixing 240 V, 4 nos. 6/16 Amp combo, 6 pin Modular type plug socket with 4 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on suitable size 2 row GI Modular type switch board with 2 row top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. | |||
| 276 | 86.01 | 4 nos. 6/16 Amp combo | 1 | Each | |
| 277 | 87 | Supply & Fixing suitable size of GI box with modular plate and cover in front on surface or in recess including providing and fixing 240V,6 pin, 2 nos 5/15Amp combo modular socket outlet and15/16Amp modular switch with moduler type indicator (Brand approved by EIC), connection etc as required. (01 no for each bed) | |||
| 278 | 87.01 | 2 nos 5/15Amp combo | 5 | Each | |
| 279 | 88 | Supplying & Fixing Industrial Plug & Socket board with 415 V, 30A, TPN & Earth Metal Industrial Plug socket & 30A Industrial top incl. S&F 32 A TPN/FP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection. Make: (Legrand/Schneider/Siemens). | 2 | Each | |
| 280 | 89 | SUPPLY OF CABLE- Supply and delivery of following size PVC/A(AL) cable. (Make- KEI/Havells/Polycab) | |||
| 281 | 89.01 | 4 core 150 sqmm. (Incommer ) | 50 | RM | |
| 282 | 89.02 | 4 core 70 sqmm. (Panel to Busbar ) | 70 | RM | |
| 283 | 90 | 2 core 10 sqmm. (Gate light/roof light/glow sign board and where neccessary as per direction of EIC). | 220 | RM | |
| 284 | 91 | LAYING OF CABLE- Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. | |||
| 285 | 91.01 | 4core 150 sqmm. | 50 | RM | |
| 286 | 91.02 | 4core 70 sqmm. | 50 | RM | |
| 287 | 92 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. | |||
| 288 | 92.01 | 2core 10 sqmm. | 120 | RM | |
| 289 | 93 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. | |||
| 290 | 93.01 | 2core 10 sqmm. | 100 | RM | |
| 291 | 94 | Laying of cable above 3½ core 50 sqmm and upto 3½ core 90 sqmm on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. | |||
| 292 | 94.01 | 4core 70sqmm. | 30 | RM | |
| 293 | 95 | GLAND AND FINISHING- Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : | |||
| 294 | 95.01 | 4 core 150 sqmm | 4 | Each | |
| 295 | 95.02 | 4 core 70sqmm | 4 | Each | |
| 296 | 95.03 | 2 core 10sqmm | 20 | Each | |
| 297 | 96 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials \n | |||
| 298 | 96.01 | 4core 150 sqmm | 12 | Set | |
| 299 | 96.02 | 4core 70 sqmm | 16 | Set | |
| 300 | 96.03 | 2core 10 sqmm | 30 | Set | |
| 301 | 97 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. | |||
| 302 | 97.01 | 16 Sqmm | 24 | Set | |
| 303 | 97.02 | 10 Sqmm | 16 | Set | |
| 304 | 97.03 | 6 Sqmm | 50 | Set | |
| 305 | 97.04 | 4Sqmm | 80 | Set | |
| 306 | 97.05 | 2.5 Sqmm | 90 | Set | |
| 307 | 98 | SUPPLY OF LIGHT FITTINGS- S/Delivery following 250 Volt, 18/20 Watt, 4 Ft. long LED Tube fittings complete with LED tube lamp having at least 100 lumen/watt and cast iron box type fittings.(Make- Philips/Crompton/Syska/Bajaj) | |||
| 308 | 98.01 | Single LED Tube(18/20 Watt) | 35 | Set | |
| 309 | 98.02 | Twin LED Tube(18/20 Watt) | 5 | Set | |
| 310 | 99 | S/F BC LED lamp (B22) as per direction of E.I.C. (Make- Philips) | |||
| 311 | 99.01 | 12 Watt | 40 | Each | |
| 312 | 99.02 | 9 Watt | 5 | Each | |
| 313 | 100 | S/F decorative bracket light on wall on wooden plank by necy. Screw etc. without lamp. \n(Make-Philips/Jaguar/Syska/havells) | 8 | Each | |
| 314 | 101 | S/F LED bulkhead fitting on suitable size wooden board as per direction of E.I.C. (MAKE- Jaquar ITEM CODE:LBLK01X010XC/Philips/Crompton/Syska/Bajaj)Philips EnduraLED Bulkhead- 10 Watt) | 20 | Each | |
| 315 | 102 | S/F Dura LED wall glass bulkhead fitting on suitable size wooden board as per direction of E.I.C 3700lm \n(Make:Philips WT202LED6&NW PSU S2PC/Jaguar/Syska/havells) (For Car Parking area) | 12 | Each | |
| 316 | 103 | Supply and fixing 240V,12W ceiling mounted Round LED panel on ceiling and necessary connection as required as to GS. \n(MAKE- Jaquar ITEM CODE:LNVE02R012SC Philips/Crompton/Syska/Bajaj) as per choice of EIC.(Front of entry and coridor) | 5 | Each | |
| 317 | 104 | FIXING OF LIGHT FITTINGS- Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. | 40 | Set | |
| 318 | 105 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. | 150 | RM | |
| 319 | 106 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling with HW block and ceiling plates, nipples etc. as required. | 35 | Each | |
| 320 | 107 | SUPPLY OF FANS- Supplying & Deliveryof 250 volts, 50 Hz 1200mm (48”) sweep A.C. ceiling fan complete with all accessories viz. down Rod,Canopy, Fork etc. including connections as reqd. as per choice of E.I.C. (Make-Orient PSPO, Model- GRATIA/ADONIS, USHA STRIKER PLUS Colour- Pearl Metallic/ White) | |||
| 321 | 107.01 | 1200mm (48”) | 25 | Set | |
| 322 | 108 | Supplying and fixing of 250 volts, 50Hz, 23cm (9”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl. providing necessary CU wire for connection & S and F louver shutter (Make-EPC) as to Gs. | |||
| 323 | 108.01 | 23cm (9”) | 8 | Set | |
| 324 | 109 | FIXING OF FANS- Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991) | 25 | Each | |
| 325 | 110 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. | 25 | Each | |
| 326 | 111 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. | 25 | Each | |
| 327 | 112 | Painting upto 10 letters of the engraved number with approved black /red paint as required | 25 | Each | |
| 328 | 113 | POWER BACKUP- Supply & installation of 1400VA Sine Wave LED display UPS with external battery provision suitable for operation in input voltage range 170V to 270V 50 Hz, Operating DC voltage 24V with Supply/Installation of 02 nos 12V 150Ah Exide make inva tall (IT) battery (Warranty not less than 24 months including making necessary connection & installation of battery unit on M.S angle frame as per requirement & suitable for installation of battery and as per direction of EIC (battery & Inverter make Microtek/Exide/Numeric) | 1 | Set | |
| 329 | 114 | MISCELENEOUS- S/F of 0.5 inch. Thick 'FR' Hylam (Phenolic laminated) sheet (3 ft x 4 ft) on wall with necessary nuts bolts etc. as required incl. S/F 1 nos. 415 Volt, 100 Amp cut out (approved make) & 4 x 16 sq. and 2 x 10 mm. insulated 'FR' copper wire ( 3 mtr. Approx) for meter loop for installation of 1 no. Three phase meter as per direction of E.I.C. | 1 | Set | |
| 330 | 115 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991)(415V, 100A,4 Bar BBC)(Dimension of Cu. bars[85mm long] & 4 x 15x3mm) | 1 | Set | |
| 331 | 116 | Supplying and fixing 100A,415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(for Main switch) | 1 | Set | |
| 332 | 117 | Supplying and fixing 32 A, 240V DP with fuse on L&N Sheet steel Main Switches on angle iron frame on wal.(make- L&T/Siemens/Legrand).(for Pump and compound light and Spare) | 3 | Each | |
| 333 | 118 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment incl. supplying and fixing 240/415 V 16/32A DP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (1 nos for roof light ,1 nos for gate light and 01 no for glow sign board and 1 Spare) ) | 4 | Each | |
| 334 | 119 | Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board | 3 | Each | |
| 335 | 120 | EARTHING- Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil) | 5 | Cum. | |
| 336 | 121 | Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level. | 2 | Set | |
| 337 | 122 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. | 1 | M | |
| 338 | 123 | Connecting the equipments to earth busbar including S & F No. 10 SWG GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. | 40 | M | |
| 339 | 124 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (25 mm dia) | 25 | M | |
| 340 | 125 | Dismantaling of all existing electrical wiring,fittings etc with co's own tools and tackles and handed over the same to the appropritate authority. | 2 | Job | |
| 341 | 126 | COMPOUND LIGHTING- Supplying and fixing of Street light fittings 60-65Watt (Specification- Pressure dia cast aluminium housing , IP-66, flat glass,constant current potted driver ,100 lu/watt , (Make -Philips/Crompton/Syska/Jaquar) | |||
| 342 | 126.01 | 60-65 Watt (Fixing only NEW POLE and Existing Pole) | 8 | Set | |
| 343 | 127 | Supply and fixing of mini GI pole on wall of the roof made with 80mm dia 2 Mtr long including fixing of MS bar plate of size 300mm x 300mm x4mm in the bottom of pole by arc welding and fixing angle iron leg of size 600 long 40mm x 6mm (2 Nos for support) the base plate on wall including making hole on fixing nuts& bolt 4 nos and necessary work as per GS. | |||
| 344 | 127.01 | 2 Mtr pole | 8 | Each | |
| 345 | 128 | S/F CI water proof type looping cable box size 200 x 150 x 100 mm deep having 4 mm thick comprising of one 250 volt 15 Amp kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for 2 core 10 sq. mm. PVC/Al cable & having lined with rubber gasketted CI top cover with brass machine screws etc. earthing terminal with lug on ST pole near base, incl. S/F 40 x 6 mm thick MS clamps with bolts nuts etc. incl painting with anticorrosive paint & providing 2 nos 40 mm dia. ISI-M GI pipe protection for incomer & outging cable. (10 nos for roof light, 2 nos for gate light ) | |||
| 346 | 128.01 | Loop Box Fixing only NEW POLE and Existing Pole [ I-2/16(a) ] | 10 | Each | |
| 347 | 129 | Painting of each Steel Tubular Pole of lengths ( Upto 9 Mtr ) with 2 coats of Aluminium Paint over 1 coat of RO primer as per GS | |||
| 348 | 129.01 | Painting | 8 | Each | |
| 349 | 130 | S&F of Single arm header assembly fabricated from 40 mm dia G.I.pipe (ISI-M) of 1.5 Mtr.long rigidly welded with 100 mm dia G.I. pipe (ISI-M) of 0.3 Mtr. Long at an angle of 110 degree & suitable angle between the two arms incl. S&F 3 nos. 1/2\" MS jam nut each with 1 no. 1/2\" dia. through bolt and painting the entire assembly.(10 nos for roof pole) | |||
| 350 | 130.01 | Single arm header | 8 | Each | |
| 351 | 131 | Providing CC (6:3:1) muffing 600x600x760 mm in size or equivalent size of cylindrical muffing above ground level around the pole base complete with 3 mm thick neatly finished cement plaster all round after dismantling the unserviceable uffing if necessary Without Loop Box | |||
| 352 | 131.01 | Muffing ( New pole and Existing Pole) | 8 | Each | |
| 353 | 132 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes through 25mm/19 mm bore 3 mm thick polythene pipe and by the GI fish wire and making necy. connection as required as per direction of E.I.C. Make:KEI/Polycab 3 x 22/0.3 (1.5 sqmm) (for compound Light Loop Box to Light Connection) | 100 | RM | |
| 354 | 133 | S/F Decorative LED Post Top Light on the top of 80mm dia GI pipe pole incl. S/F of 50mm dia GI pipe of 1 ft. length on the top of the pole by welding method as per direction of E.I.C with Lamp (Specification- Pressure dia cast aluminium housing , IP-66, flat glass,constant current potted driver ,100 lu/watt , \n(Make -Philips/Crompton/Syska/Jaquar) | 2 | Each | |
| 355 | 134 | GLOW SIGN BOARD- Supply & Fiixing of outdoor type LED SIGN Board (15'(L)x6''(B)x4'(W)) fabricated from 3 mm thick ACP sheet on all six sides finished with approved metallic colour & suitable size hollow Al rectangular bar as frame inside the box. All LED Module, wiring to be fixed inside the ACP box. Silicon adhesives, SS screws to be used in such a way so that ingress of water can be restricted inside the box and maintenence/replacement of the LED modules can be done easily. All screws/nuts & bolts/clamps etc metals used inside the box should be of non-ferrous metal/Stainless steel. Appropriate size of MS Angle, nuts/bolts and clamp to be used outside for fixing the box. | 60 | Sq. ft. | |
| 356 | 135 | Supply & Fixing of Special type of 3D Boxing type letter with top cover openable made from imported 3mm thick Acrylic sheet to accomodate LED module. Only front side of the letter should emit light. side to be made from opaque acrylic sheet. Letter height, width & depth of the letter will be proportionate & as per direction of E.I.C.. Suitable Ratio should be maintained between the letter size, spacing between each letters & spacing between each words as per the direction of the E.I.C. (Calculation of area (square inch) of a letter will be HeightXBreadth of the letter inclusive all wastage. | 4250 | Sq. inch. | |
| 357 | 136 | Supply & Fixing of LED within the acrylic letter from backside (Make: SAMSUNG/Meanwell or equivalent) having the following specifications: COLOUR:WHITE or as per the choice of EIC. LIFE:70,000 burning hours. INTENSITY: Uniform without any bright/dark patches. VISIBILITY: 100Mtrs at least for normal eye vision. AMBIENT AIR: 0-50°C; 100% Relative Humidity. POWER CONSUMPTION: 1.5 Watt per module. (1 module consists of 3 nos LED) | 500 | Module | |
| 358 | 137 | SITC of water proof Power Supply unit to be fitted inside the Sign board box. inclusive of water tight gaskette fitted stainless steel hinged door box. Input: 100V-240V AC; 4A; 50Hz. Output: 12V DC; 17-20A constant power supply. Make: Meanwell/Ven/Resang or equivalent. | 4 | Item | |
| 359 | 138 | Supply & Fixing MS Structure for holding 15'x4' LED sign board by 65x65x6 angle as Vertical members and 50x50x6 angle and 25x6 MS flat as horizontal member including painting the MS structure and fixing with CC foundation on the roof as per direction of the EIC. | 1 | Job | |
| 360 | 139 | Supply & Laying 2 core x 6 sq.mm PVC/A(AL) cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. Mending good damages and Painting. | 75 | RM | |
| 361 | 140 | Supplying and Fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured Cables as below: \na) For 2 cores: upto 6 sqmm. | 4 | Each | |
| 362 | 141 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels Make), tapes, anticorrosive paste & jointing materials: a)For 2 cores 6 sqmm. Cable | 4 | Set | |
| 363 | 142 | Supplying and fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in wall incl. painting. a)200x150x100mm. | 1 | Each | |
| 364 | 143 | AC INSTALLATION- Supply and delivery of 2TR Split type Room Air Conditioner with rotary compressor and copper coiled of 2 TR Capacity- 4 Star Rated with cutting necessary holeson wall/wooden/iron grill etc. incl. S&F necy. Iron base channel etc. incl. mending good the damages to original finish Upto 3 Mtr copper pipe & allied interconnection with high quality Adiabatic cover as inner layer and cover with lapping tape as required as per direction of E.I.C. (Make- O-General ,R-410A, cat no. ASGA24FETA/ Mitsubhisi Heavy duty). | 1 | Nos. | |
| 365 | 144 | S & F of extra length of copper pipe lines of suitable size connecting indoor to outdoor unit with connecting cables/wires of 1.1KV grade, PVC insulated and sheathed 4 core, 2.5 Sq.mm. stranded copper wire and covering the copper pipes with high quality Adiabatic cover as inner layer and cover with lapping tape as second layer, best quality Adhesive tape as third layer and Asbestors Rops as extreme outer and final laping layer as per direction of E.I.C. | 10 | M | |
| 366 | 145 | Carrying charges for A.C machines. | 1 | Nos. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender