Military Engineer Services-MES has published Maintenance And Repairs To Pump Sets , Motors , Apfc Panels , Water Level Indicators Etc At Pumping Installations And Connected Water Supply Works Under Ge ( I ) R Nd D ( West ) , Bangalore. Submission Date for this Tender is 25-02-2020. Power Factor Panel Tenders in Bengaluru Karnataka. Bidders can get complete Tender details and download the document.
Name of Work: MAINTENANCE AND REPAIRS OF PUMP SETS, MOTORS, APFC PANELS, WATER LEVEL INDICATORS ETC AT PUMPING INSTALLATIONS AND CONNECTED WATER SUPPLY WORKS UNDER GE (I) R&D (WEST) BANGALORE | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 0 | SCHEDULE OF WORKS | |||
2 | 1 | Overhauling and Refurbishing of Induction motors of 120 HP capacity by carrying out the following works :- \n(a) Disconnecting Power supply, taking out the motor from foundation by dismantling the coupling and shifting to workshop from site,\n(b Dismantling the motor assembly, cleaning of winding for all traces of dust & grease and cleaning the inner surfaces by petrol. Pre-heating of stator in the heating chamber at 1000C for 4 hours and applying of bectol red finishing varnish over the winding,\n(c) Carrying out mechanical observations for any abnormality of spigot, end shields, shaft, housing, mounting etc ., re-metaling and turning/polishing of shaft if required, checking of bearings cleaning & greasing, balancing of rotor to assess any vibration and to arrest the same if any and assembling the motor,\nd) Final checking of electrical parameters and to test run on No-load and measure the No-load current, after satisfactory test, painting with one coat of enamel paint of existing shade .\n(e) Shifting the motor assembly to the place of work, installing on the bed, coupling with pump, checking, aligning and conducting load test to the satisfaction of EIC.\nNOTES:- (i) Transportation and necessary T & P for shifting the motor to workshop & back is deemed to be included in the quoted rates.\n(ii) Major spares like bearings, Coupling etc., will be measured and paid under relevant items of this schedule. | 2 | EACH | |
3 | 2 | All as per Sl Item No. 1 here-in-above but 100 HP. | 2 | EACH | |
4 | 3 | All as per Sl Item No. 1 here-in-above but 75 HP. | 2 | EACH | |
5 | 4 | All as per Sl Item No. 1 here-in-above but 50 HP/ 40 HP. | 10 | EACH | |
6 | 5 | All as per Sl Item No. 1 here-in-above but 30 HP. | 4 | EACH | |
7 | 6 | All as per Sl Item No. 1 here-in-above but 12.5 / 15 HP. | 4 | EACH | |
8 | 7 | All as per Sl Item No. 1 here-in-above but 10 HP. | 10 | EACH | |
9 | 8 | All as per Sl Item No. 1 here-in-above but 7.5 HP. | 5 | EACH | |
10 | 9 | All as per Sl Item No.1 here-in-above but 5 HP. | 2 | EACH | |
11 | 10 | All as per Sl Item No.1 here-in-above but 3 / 2.5 HP. | 7 | EACH | |
12 | 11 | Disconnecting the motor of 100 HP capacity by delinking the pump set, transporting to workshop, opening the motor, removing the unserviceable / burnt windings from the motor stator, cleaning the stator slots with petrol, rewinding with existing size of copper winding wire, insulating to the existing class of insulation varnishing, ovening etc., testing at factory under No load, reassembling, transporting to site, fixing on foundation, re-connecting the motor and testing at load to the satisfaction of Engineer-in-charge. \nNOTES:- \n(i) Transportation and necessary T&P for shifting the motor to workshop & back is deemed to be included in the quoted rates.\n(ii) Major spares like coupling, bearings etc will be measured and paid under relevant items of this schedule. | 2 | EACH | |
13 | 12 | All as per Sl Item No. 11 here-in-above but 75 / 50 HP. | 3 | EACH | |
14 | 13 | All as per Sl Item No. 11 here-in-above but 40 / 30 HP. | 2 | EACH | |
15 | 14 | All as per Sl Item No. 11 here-in-above but 15 / 12.5 / 10 / 7.5 HP. | 10 | EACH | |
16 | 15 | All as per Sl Item No. 11 here-in-above but 2.5 / 3 / 5 HP. | 3 | EACH | |
17 | 16 | Supply only Driving End (DE) and Non-driving End (NDE) bearings suitable for 120 /100 HP motor all as directed. | 4 | EACH | |
18 | 17 | All as per Sl Item No. 16 here-in-above but 75 / 50 HP. | 4 | EACH | |
19 | 18 | All as per Sl Item No. 16 here-in-above but 40 / 30 HP. | 3 | EACH | |
20 | 19 | All as per Sl Item No. 16 here-in-above but 15 / 10 / 7.5 HP. | 8 | EACH | |
21 | 20 | All as per Sl Item No. 16 here-in-above but 3 / 5 HP. | 4 | EACH | |
22 | 21 | Disconnecting the Centrifugal pump set of 120 HP capacity from motor by dis-engaging the coupling, taking out the pump from the foundation and transporting to the workshop, opening the pump, taking out the shaft along with impeller, removing the foreign materials from the inner casing, cleaning, checking for wearing out of the impeller, bearing, sleeves, shaft etc., replacing the worn out parts, assembling the pump complete by replacing the gasket, nuts, bolts, washers, greasing of bearing all as required , transporting pump to the site, mounting on base frame, checking for proper alignment of pump shaft with motor shaft, adding the shims steel sheets as required, checking with dial gauge for correct alignment, connecting the shafts with coupling and test running for smooth operation all specified and as directed. \nNOTES:- \n(i) Transportation and necessary T&P for shifting the motor to workshop & back is deemed to be included in the quoted rates.\n(ii) Major spares like impeller, sleeves etc will be measured and paid under relevant items of this schedule.\n | 2 | EACH | |
23 | 22 | All as per Sl Item No. 21 here-in-above but 100 HP. | 2 | EACH | |
24 | 23 | All as per Sl Item No. 21 here-in-above but 75 HP. | 2 | EACH | |
25 | 24 | All as per Sl Item No. 21 here-in-above but 50 / 40 HP. | 9 | EACH | |
26 | 25 | All as per Sl Item No. 21 here-in-above but 30 HP. | 4 | EACH | |
27 | 26 | All as per Sl Item No. 21 here-in-above but 12.5 / 15 HP. | 4 | EACH | |
28 | 27 | All as per Sl Item No. 21 here-in-above but 10 HP. | 8 | EACH | |
29 | 28 | All as per Sl Item No. 21 here-in-above but 7.5 HP. | 5 | EACH | |
30 | 29 | All as per Sl Item No. 21 here-in-above but 5 HP. | 2 | EACH | |
31 | 30 | All as per Sl Item No. 21 here-in-above but 2.5 / 3 HP. | 7 | EACH | |
32 | 31 | Supply only CI sleeves suitable for centrifugal pump of capacity 120 / 100 HP complete all as specified and as directed. | 3 | EACH | |
33 | 32 | All as per Sl Item No. 31 here-in-above but 75 / 50 HP. | 4 | EACH | |
34 | 33 | All as per Sl Item No. 31 here-in-above but 30 / 40 HP. | 4 | EACH | |
35 | 34 | All as per Sl Item No. 31 here-in-above but 10 / 15 HP. | 4 | EACH | |
36 | 35 | All as per Sl Item No. 31 here-in-above but 3 / 5 / 7.5 HP. | 3 | EACH | |
37 | 36 | Supply only Cast Iron impeller suitable for 120 / 100 HP capacity pump set complete all as specified and as directed. | 2 | EACH | |
38 | 37 | All as per Sl Item No. 36 here-in-above but 75 / 50 HP. | 2 | EACH | |
39 | 38 | All as per Sl Item No. 36 here-in-above but 30 / 40 HP. | 2 | EACH | |
40 | 39 | All as per Sl Item No. 36 here-in-above but 12.5 / 15 HP. | 4 | EACH | |
41 | 40 | All as per Sl Item No. 36 here-in-above but 10 / 7.5 HP. | 7 | EACH | |
42 | 41 | All as per Sl Item No. 36 here-in-above but 5 / 3 / 2.5 HP. | 4 | EACH | |
43 | 42 | Supply only Love joy coupling complete with star bushes for the following capacity of the motors including dismantling the existing unserviceable coupling all as directed for Centrifugal pump set driven by 120 / 100 HP Capacity 3 phase, 415 Volts 50 Hz, AC, supply complete all as specified and as directed. | 4 | EACH | |
44 | 43 | All as per Sl Item No.42 here-in-above but 75 HP. | 3 | EACH | |
45 | 44 | All as per Sl Item No.42 here-in-above but 50 / 40 HP. | 4 | EACH | |
46 | 45 | All as per Sl Item No.42 here-in-above but 30 HP. | 3 | EACH | |
47 | 46 | All as per Sl Item No.42 here-in-above but 12.5 / 15 HP. | 4 | EACH | |
48 | 47 | All as per Sl Item No.42 here-in-above but 10 HP. | 5 | EACH | |
49 | 48 | All as per Sl Item No.42 here-in-above but 7.5 HP. | 3 | EACH | |
50 | 49 | All as per Sl Item No.42 here-in-above but 5 / 3 / 2.5 HP. | 6 | EACH | |
51 | 50 | M & L for lifting of Submersible pump assy from borewell , shifting to workshop , dismantling the motor , megger testing the motor, removing the burnt damaged winding & rewinding with appropriate size of copper winding wires re-insulation with appropriate class of insulation to the existing class,varnishing and baking, replacing the wornout bearing /bushing ,assembling & testing of motor. Opening the pump set cleaning the impellers supplying and fixing required Nos of bearing, bush after removing existing worn out bush bearing of pump set upto 08 stages ,assembling the pump , re-assembling the motor & pump ,shifting to site and lowering the pump set along with GI pipes & cables including testing complete of 5/6 HP capacity all as directed. Note : GI socket heavy duty if required replacement during lifting/lowering of GI pipe / Impellers etc will be measured & paid seperatly. | 2 | EACH JOB | |
52 | 51 | M & L for lifting the submersible non clog type p/set from sewage well , disconnecting the cable , transporting the p/set to workshop , dismantling the motor , megger testing the motor, removing the burnt damaged winding & rewinding with appropriate size of copper winding wires re-insulation with appropriate class of insulation to the existing class,varnishing and bakeing, replacing the wornout bearing /bushing ,assembling & testing of motor. Opening the pump set cleaning the impellers supplying and fixing required Nos of bearing, bush after removing existing worn out bush bearing of pump set upto 08 stages ,assembling the pump , re-assembling the motor & pump , ,shifting to site , connecting the cable and lowering the pump set along with GI pipes & cables including testing complete of 10 HP capacity all as directed. Note : Major spares like Impeller etc will be measured & paid seperatly. | 2 | EACH JOB | |
53 | 52 | Supply only Bronze impellers suitable for multi stage non clog submersible pump set 5/6 HP capacity complete all as specified and as directed. | 6 | EACH | |
54 | 53 | Supply only Bronze impellers suitable for multi stage non clog submersible pump set 10 HP capacity complete all as specified and as directed. | 6 | EACH | |
55 | 54 | Taking out old unserviceable star delta starter, supply and fix new, Star delta starter fully automatic in sheet metal enclosure type MN with SPP features suitable for operation of pumping set connected with induction motor of 30 HP capacity 3 phase, 415 volts 50 Hz AC supply complete all as per L&T Cat No: MN 32 FASD SS 94366 of L&T or its techno commercially equivalent in other makes specified and as directed. | 4 | EACH | |
56 | 55 | Taking out old unserviceable star delta starter, supply and fix new, Star delta starter fully automatic in sheet metal enclosure type MN with SPP features suitable for operation of pumping set connected with induction motor of 15 HP capacity 3 phase, 415 volts 50 Hz AC supply complete all as per L&T Cat No: MN 16 FASD SS 94362 of L&T or its techno commercially equivalent in other makes specified and as directed. | 5 | EACH | |
57 | 56 | Taking out old unserviceable starter complete, supply and fix single phase motor starter, single phase, suitable for 3 HP all as per L&T Cat No: MF1 - SS97227OOCO of L&T or its techno commercially equivalent in other makes specified and as directed. | 4 | EACH | |
58 | 57 | Taking out old unserviceable DOL starter, supply and fix new, DOL starter fully automatic in sheet metal enclosure type MN with SPP features suitable for operation of pumping set connected with induction motor of 10 HP capacity 3 phase, 415 volts 50 Hz AC supply complete all as per L&T Cat No: MN 16 DOL SS 94351 of L&T or its techno commercially equivalent in other makes specified and as directed. | 5 | EACH | |
59 | 58 | All as per Item Srl No 57 here in before but for 10 HP capacity submersible pump set Make : L&T Cat No : MU-G10H DOL starter SS 95974 or its Equivalent. | 3 | EACH | |
60 | 59 | All as per Item Srl No 57 here in before but for 5/6 HP capacity submersible pump set Make : L&T Cat No : MU-G6 DOL starter SS 97756 or its Equivalent. | 2 | EACH | |
61 | 60 | Taking out old unserviceable contactors, supply and fix new, Three pole power contactor MNX 140, 415 Volts, 140 Amps capacity, 50 Hz to suit to existing starter with 2 NO/2NC complete all as per L&T Cat No. CS 94138 or its equivalent in other makes specified and as directed. | 6 | EACH | |
62 | 61 | Taking out old unserviceable contactors, supply and fix new, Three pole power contactor MNX 95, 415 Volts, 95 Amps capacity, 50 Hz to suit to existing starter with 2 NO/2NC complete all as per L&T Cat No. CS 94136 or its equivalent in other makes specified and as directed. | 6 | EACH | |
63 | 62 | Taking out old unserviceable contactors, supply and fix new, Three pole power contactor MNX 45, 415 Volts, 45 Amps capacity, 50 Hz to suit to existing starter with 2 NO/2NC complete all as per L&T Cat No. CS 97074 or its equivalent in other makes specified and as directed. | 6 | EACH | |
64 | 63 | Taking out old unserviceable contactors, supply and fix new, Three pole power contactor MNX 32, 415 Volts, 32 Amps capacity, 50 Hz to suit to existing starter with 2 NO/2NC all as per L&T Cat No. CS 94111 or its equivalent in other makes specified and as directed. | 10 | EACH | |
65 | 64 | Taking out old unserviceable contactors, supply and fix new, Three pole power contactor MNX 25, 220 Volts, 25 Amps capacity, 50 Hz to suit to existing starter with 2 NO/2NC complete all as per L&T Cat No. CS 94110 or its equivalent in other makes specified and as directed. | 10 | EACH | |
66 | 65 | Taking out old unserviceable relays, supply and fix new, Bimetal over load relays MN 12 type with built-in single phase protection CT operated, separate mounting 90-150 Amps all as per L&T Cat No. SS94138OOMO or its techno commercially equivalent in other makes specified and as directed. | 10 | EACH | |
67 | 66 | Taking out old unserviceable relays, supply and fix new, Bimetal over load relays MN 2 type with built-in single phase protection CT operated, separate mounting 9-15 Amps suitable for MNX 25/32 contactor all as per L&T Cat No. SS94142OOBO or its techno commercially equivalent in other makes specified and as directed. | 6 | EACH | |
68 | 67 | Taking out old unserviceable contactors, supply and fix new, ML-3 type power contactor 3 phase, 415 volts, 50 Hz, AC, 40 Amps capacity coil voltage, 415 Volts with aux. contacts 2 NO + 2 NC all as per L&T Cat No. SS90721 or its equivalent in other makes specified complete all as specified and as directed . | 6 | EACH | |
69 | 68 | Taking out old unserviceable contactors, supply and fix new, ML-2 type power contactor 3 phase, 415 volts, 50 Hz, AC, 32 Amps capacity coil voltage, 415 Volts with aux. contacts 2 NO + 2 NC all as per L&T Cat No. SS90701 or its equivalent in other makes specified complete all as specified and as directed . | 5 | EACH | |
70 | 69 | Taking out old unserviceable contactors, supply and fix new, ML-1.5 type power contactor 3 phase, 415 volts, 50 Hz, AC, 25 Amps capacity coil voltage, 415 Volts with aux. contacts 2 NO + 2 NC all as per L&T Cat No. SS91851 or its equivalent in other makes specified complete all as specified and as directed . | 6 | EACH | |
71 | 70 | Supply only high strength calcium based granular disinfectant (with 60 to 70 % Chlorine) for chlorination of water. Make : Any make approved by E-in-C's Branch, AHQ New Delhi.\nNote: (i) Supplier shall provide a "certificate of compliance"/Test certificate in original indicating Batch No., date of manufacturing, and quantity supplied.\n(ii) Supply of materials shall be regulated as per work orders issued time to time as per the requirement. \n(iii) Only fresh lot (not more then two months at the time of received material) shall be supplied by the contractor. Batch no and date should be marked on every container. | 3000 | KILO GRAM | |
72 | 71 | Supply and fix MPP capacitors, heavy duty, cylindrical (gas filled) 440 Volts 16 to 25 KVAR capacity and connecting complete including taking out un serviceable capacitors complete all as directed. | 5 | EACH | |
73 | 72 | Supply only GI socket heavy duty 50mm including fitting etc all as directed by engineer-in-charge. | 18 | EACH | |
74 | 73 | S&F On Load change over switch, four pole 400A, 415 volts AC, manual changeover open execution type with handle including taking down old change over switch connection complete all as directed. Make L & T Cat NO CO440000000 or its equivalent. | 2 | EACH | |
75 | 74 | S&F MCCB TP 63 Amps Capacity with rupturing capacity 10 kA on the existing panel board including taking down old MCCB connecting complete all as directed. Make : L&T Type DU 100B Cat No CM90545OOHY | 8 | EACH | |
76 | 75 | All as per Item ser No 74 here in before but TP 100 Amps 18 kA with thermal release range 80-100Amps including taking down old MCCB and connecting complete all as directed. Make L&T type DU100D Cat No CM9051700Ko or its equivalent. | 8 | EACH | |
77 | 76 | All as per Item ser No 74 here in before but TP 200 Amps 25 kA with thermal release range 160-200Amps including taking down old MCCB and connecting complete all as directed. Make L&T type DU 250C Cat No CM9063100N0 or its equivalent. | 8 | EACH | |
78 | 77 | M & L for disconnecting the electrical connections from panel to sewage motor 30 HP, dis-connecting the pump & motor and shifting the same to the upper platform from the sewage well carefully using necessary T & P and dismantling the rusted structural steel base plate from the foundation bed, fabricating new base plate using structural steel sections of the same shape & size of the existing base plate ,applying two coats of synthetic enamel black paint over a coat of red oxide fixing complete on the existing foundation bed, using new foundation bolts as required at site. lowering of the pump & motor , fixing on the base plate with proper shaft alignment and connecting with coupling , connecting the electrical & water connections ,checking for smooth running of the pump complete all as directed.\nNote :- 1) Steel sections and coupling will be measured and paid separately under respective items of schedule.\n2) The quoted rates are inclusive of necessary T & P , painting , nuts , bolts , washers etc. | 2 | JOB | |
79 | 78 | M & L for rolled mild steel in joists , channel , angle or tee sections as in main and cross beams of Fe 410-W grade steel for common base plate for pumping set including grinding sharp corners etc all as directed. Note :- The quoted rates are inclusive of unloading , fabrication work at site, reducing to required shape & size ,hoisting , fixing etc all as required at site | 180 | KILO GRAM | |
80 | 79 | Supply only Chloroscope (Chlorine test Kit) for range 0.1 ppm to 2.0 ppm all as specified and as directed. Make : Water-Chem / RMCO / Good Edge | 5 | EACH | |
81 | 80 | Supply only O - toluidine regent solution in 500 ml bottle all as specified and as directed. Make : NICE / Qualigens / RMCO | 5 | EACH | |
82 | 81 | Supply and installation with testing complete of digital water level indication device, operating on single phase supply direct display in 19mm size (letter display) digit system in meter/CM of water of over head tank ensuring alarm while water fall or rise over predetermined limits with the following description complete all as specified and as directed by Engineer-in-charge including dismantling old unserviceable water level indicator.\n(a) The entire unit must operate through a compact electronic circuit which must ensure reliable operation at 230V + 10% at 50 Hz + 5%, with reliable in display and alarm at low and high level of over head tank.\n(b) One circuit must be housed in high impact polystyrene molded box with nylon molded connection strips. The level system must resistance transducer, while unattested by corrosion and other contents available in water. The product must be controlled by Micro switch.\n(c) The whole unit must electronically controlled and the upper level and lower level indications must be in two parts. Each complete part must be fitted in MS CRS sheet box separately. One must be installed at over head tank and second at pump house with proper powder coating paint with locking arrangements. \nMake : SECO Type : DDS - 02. | 6 | JOB | |
83 | 82 | M & L for laying, connecting & testing four core copper conductor flexible PVC insulated heavy duty unsheathed cable 1100 volts grade 0.5 Sqmm from control box to display meter in ducts/on ground /through existing pipes etc including taking out unserviceable flexible cable all as specified and as directed. | 280 | RUNNING METER | |
84 | 83 | Supply & Fix 3 Phase digital voltmeter Class 1 panel mounted and connecting complete including taking out U/s voltmeter complete all as directed. | 5 | EACH | |
85 | 84 | Supply & Fix 3 Phase digital ammeter 5 amps Class 1 panel mounted and connecting complete including taking out U/s ammeter complete all as directed. | 6 | EACH | |
86 | 85 | Supply & Fix APFC Relay 8 stages with Auto set function input voltage 415 volts , CT secondary 5 Amps connecting complete including taking out U/s APFC relay complete all as directed.Make L&T Model or equivalent | 1 | EACH | |
87 | 86 | M & L for laying, connecting & testing Flat cables for sewage non clog pumps three core copper conductor flexible PVC insulated & PVC sheathed heavy duty cable 1100 volts grade 10 Sqmm from panel to motor duly clamped on walls, run through conduits etc including taking out unserviceable cable all as specified and as directed. | 240 | RUNNING METER | |
88 | 87 | Material and Labour for scraping the peeled off paint of pumping set 120 HP /100 HP capacity along with base foundation plate, applying metal paste on uneven surfaces to make the surface smooth and applying a coat of synthetic enamel paint of existing shade and writing the MES / SM number on the motor / pump set all as directed. | 4 | JOB | |
89 | 88 | All as per Item Ser No 87 here-in-before but 75 HP capacity | 2 | JOB | |
90 | 89 | All as per Item Ser No 87 here-in-before but 50/40/30 HP capacity | 14 | JOB | |
91 | 90 | All as per Item Ser No 87 here-in-before but 15/12.5 /10/7.5 HP capacity | 11 | JOB | |
92 | 91 | All as per Item Ser No 87 here-in-before but 5/3/2.5 HP capacity | 9 | JOB | |
93 | 92 | Material and Labour for scraping the peeled off paint of suction / delivery water lines / MS duct covers / control valves at pumping installations applying metal paste on uneven surfaces as necessary to make the surface smooth and applying a coat of synthetic enamel paint of existing shade and sign writing all as directed. | 20 | JOB | |
94 | 93 | Material and labour for preparation of old painted surfaces of electrical panels/cable tray/ladders etc of any description over 10cm in width or girth and spray painting of one coat of synthetic enamel paint of existing shade and sign writing the description as directed. | 120 | SQUARE METER | |
95 | 94 | Supply & Fix in repairs MCCB 400 Amps 35 KA 4 Pole Thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make- Lexic Legrand (DPX)/ Schneider Compact NSX/L&T (Hager). | 2 | EACH | |
96 | 95 | Supply & Fix in repairs MCCB 250 Amps 35 KA 4 Pole Thermal magnetic release trip unit 415 Volt AC, 50 Hz , including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make- Lexic Legrand (DPX)/ Schneider Compact NSX/L&T (Hager). | 2 | EACH | |
97 | 96 | Supply & Fix in repairs MCCB 200 Amps 25 KA 4 Pole Thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make- Lexic Legrand (DPX)/ Schneider Compact NSX/L&T (Hager). | 3 | EACH | |
98 | 97 | Supply & Fix in repairs MCCB 100 Amps 25 KA 4 Pole Thermal magnetic release trip unit 415 Volt AC, 50 Hz, including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make- Lexic Legrand (DPX)/ Schneider Compact NSX/L&T (Hager). | 3 | EACH | |
99 | 98 | Supply and fix in repairs MCCB, 4 pole, 415 Volts, 125 Amps, 25 KA, 50 Hz, AC including connecting up incoming/ out going cables with suitable lugs and testing complete all as specified and as directed. Make: L&T/Lexic legrand/Schneider/ABB. | 3 | EACH | |
100 | 99 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6.0mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m deep below normal ground level connected to galvanized earth wire 4 mm dia, 7.5m length by means nuts, check nuts and washers of GI or steel connected to main switch board including watering arrangement with PCC chamber MS wire gauge, CI cover with frame including excavation in any strata and returning, filling, removal surplus soil, charcoal salt complete all as shown in electric plate No 5 of SSR Part I (Earth test point shall be provided at suitable point). | 4 | EACH | |
101 | 100 | Taking out old unserviceable contactors, supply and fix new, Capacitor duty contactors type MO C25 with built in contacts 1NO & 1NC for 25 KVAR rating at 415 volts, 3 Phase, 50 Hz and connecting complete all as specified and as directed. | 4 | EACH | |
102 | 101 | Supply only stainless steel Pump shaft with key slot & key suitable for 50 HP Pump set including grinding / polishing works complete. | 6 | EACH | |
103 | 102 | Supply only stainless steel Pump shaft with key slot & key suitable for 15/10 HP Pump set including grinding / polishing works complete. | 7 | EACH | |
104 | 103 | S & Fixing Electrically operated at 240 Volt 50 Hz ,Liquid chemical injector single head high pressure adjustable gear dozing pump of capacity 02 USGPD to 40 USGPD at 100 PSIG with all accessories including taking down the old unserviceable one with 04 nos Rubber tubes complete all as per Model no : RPQ 40 HD of RMCO or equivalent Milton/ Aquafit and the spares like PVC tube upto 2 Mtr / housing nut bolts etc as required to make the system fully functional and testing complete all as specified and as directed. \nMake : Any make approved by E-in-C's Branch, AHQ New Delhi. | 2 | EACH SET |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail