Calcutta State Transportation Corporation has published Tender For Electrification Work At Taratala Depot Along With H . T . Work Under Cstc . 2Nd Call. Submission Date for this Tender is 19-02-2020. Electrification Work Tenders in Taratala Depot West Bengal. Bidders can get complete Tender details and download the document.
Name of Work : Electrification work at Taratala Depot along with H.T. work under CSTC. | |||||
---|---|---|---|---|---|
Sl. No. | Item Description | Item Code / Make | Quantity | Units | |
1 | 1 | Supplying and fixing 415V, TPN on load front\noperated Changeover switch with Sheet Steel\nenclosure on angle iron frame on wall with nuts\nbolts etc. 320 amp HPL/Havells/Standard make\nas per direction of EIC.\n\n\n | 1 | 1 | Each |
2 | 2 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating on angle iron frame on wall (L&T/HPL/Havells make) as per direction of EIC.\na) 32 amp\n\n | 2 | 15 | Each |
3 | 2.1 | b) 63 amp\n | 10 | Each | |
4 | 2.2 | c) 100 amp\n | 5 | Each | |
5 | 2.3 | d) 200 amp | 5 | Each | |
6 | 3 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Legrand/Schneider/ Crabtree make)2+12 way enclosure as per direction of EIC\n | 30 | Each | |
7 | 4 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/Schnider/ Crabtree make) as per direction of EIC.\n 8 way enclosure. \n\n | 15 | Each | |
8 | 5 | Supplying and fixing 415 V Four Pole MCCB of\nBreaking capacity 25kA/35kA with fixed thermal\nand fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. 63 amp.(Legrand/ Schnider/ Crabtree make)\nas per direction of EIC.\n \n\n\n | 15 | Each | |
9 | 6 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection (Legrand/ Schnider/ Crabtree make)\nas per direction of EIC.\na) 6-32 amp SP\n | 300 | Each | |
10 | 6.1 | b) 40 amp DP \n | 30 | Each | |
11 | 7 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.(Average run 8 mtrs)\n | 400 | Pts. | |
12 | 8 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.\n(Average run 1.5 mtrs)\n | 200 | Pts. | |
13 | 9 | Supply and delivery of 180 watts OPTIMUS street light 16200 lumen as per direction of EIC (Magik/Nordusk/Syska)\n\n\n | 20 | Each | |
14 | 10 | Supply ,delivery of 1.1KV grade single core standard FR PVC insulated, unsheathed single standard copper wire (3x22/0.3+ 1.5 sq mm) loop box to LED fittings.\n\n | 200 | Mt. | |
15 | 11 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint\n\n\n | 22 | Each | |
16 | 12 | Supply , Delivery Fitting ,Fixing of street light luminaries for 180W, 240 volt LED light optimus street light with complete sets including connection etc. as required.(as per direction of EIC)\n(Magik/Nordusk/Syska)\n\n | 30 | Each | |
17 | 13 | Supplying of Auto street light control unit (TVC make type LS-1) causing of one , one no. time switch (Type-T/SO/L$ T make) suitable to switch On and Off one 32 A LT or BCH make contractor on load, 1 to 5A switch for manual operation the constancy one no. side lock fuse to control circuit assemble on a suitable chassis.\n\n | 2 | Each | |
18 | 14 | Supplying & Laying of Alu. Armoured 1.1 KV grade cable upto 3/4 core 35 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. (Nicco, Mescab & R.R. Cable make) (as per direction of EIC).\na) 2 core 10 sq mm\n\n | 400 | M | |
19 | 14.1 | b) 4 core 16 sq mm\n\n | 400 | M | |
20 | 14.2 | c) 4 core 35 sq mm | 400 | M | |
21 | 15 | Supplying and filtration of transformer power oil, brand(IS-335). \n | 400 | Ltr. | |
22 | 16 | Lifting of core by chain pully block and removing of slages & cleaning the transformer after disconnection the L.T & H.T side again commissioning the transformer.\n | 1 | Item | |
23 | 17 | Supplying & replacement of Dog brand RC-70C gaskets of the 250 KVA transformer. | 1 | Item | |
24 | 18 | Supplying and replacement of silica gel unit.\n | 1 | Item | |
25 | 19 | Painting of transformer by approved paint after\nserabing the old paint.\n\n | 1 | Item | |
26 | 20 | Repairing of L.T panel after disconnection & re-connection of incoming & outgoing cableand painting by approved paint.\n\n\n | 1 | Item | |
27 | 21 | Supplying &l aying of cable above 4 core 70 sqmm Al. armoured cable (Gloster/Mescab) on wall/surface including S & F MS clams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy., mending good damages and painting. (as per direction of EIC)\n\n\n | 200 | Mtr. | |
28 | 22 | Supplying and installation of LED main stream battens MAGIK/ Nordusk/Syska make 36W, Prism line, product code- BWPL036C0667 as per direction of EIC | 200 | Each | |
29 | 23 | Supplying and fixing of 40 inch sweep ceiling fan (Crompton Greeves Decora premium/Bajaj/Polar)as per direction of EIC.\n | 34 | Each | |
30 | 24 | Supplying and installation of air circuit breaker 630 amp, 50 KA, MDO, N-type basic code-BN064CM0D0D0NGO (HPL/ Havells/Standard make). Other specification consult with EIC. \n | 1 | Each | |
31 | 25 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of t 2x56/0.3 (4sq mm )+1x36/0.3 (2.5 sq mm) in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.\n\n\n | 1000 | M | |
32 | 26 | Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 x 19/8 stranded GI (Hot Dip) wire (4 Mts. long), 25 mm dia x 150 mm long galvanized bolt, double nuts, double washers including socketing at both ends of stranded GI (Hot Dip) wire by crimping sockets/ thimbles and S & F 40 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts | 15 | Each | |
33 | 27 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 65 mm x 8 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. | 10 | Each | |
34 | 28 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried\ninside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and\nmending good damages. 4 SWG\n | 500 | Mtr. | |
35 | 29 | Wiring with 1.1 KV grade single core PVC\ninsulated stranded Copper wire in EI conduit/GI conduit and painting 2x4 sqmm wire in 19 mm conduit incl. S&F\n1x14 SWG GI ECC. (as per direction of EIC)\n | 1980 | M | |
36 | 30 | Supply, delivary, fitting fixing LED flood light MAGIK/Nordusk/Syska make 150 watt product as per direction of EIC | 30 | Each\n\n | |
37 | 31 | ADD : GST - 18% (SGST = 9% & CGST = 9%) | 1 | no. | |
38 | 32 | ADD : WEST BENGAL LABOUR WELFARE CESS = 1% | 28 | 1 | no. |
39 | Total in Figures |