Supply , Installation , Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Sarla ( Slra ) Of Sbp Division, RITES Ltd-Haryana

Rail India Technical And Econimics Services Ltd-RITES has published Supply , Installation , Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Sarla ( Slra ) Of Sbp Division. Submission Date for this Tender is 05-03-2020. Gear Product Tenders in RITES Ltd Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

23491480
Supply , Installation , Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Sarla ( Slra ) Of Sbp Division
Open Tender
Indian
Haryana
RITES Ltd
05-03-2020

Tender Details

Supply , Installation , Testing And Commissioning Of Indoor And Outdoor Gears Of Signalling And Telecommunication System Including Electronic Interlocking System At Sarla ( Slra ) Of Sbp Division

Key Value

Document Fees
INR 10000 /-
EMD
INR 784467.0 /-
Tender Value
INR 7.84 Crore /-

BOQ Items

Name of Work: Supply, Installation, Testing & Commissioning of Indoor & Outdoor gears of Signalling & Telecommunication system including Electronic Interlocking system at SARLA (SLRA) of SBP division
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Schedule- A Supply Signalling
2 2 Design, manufacture and supply of Electronic Interlocking (EI) system with hot standby complete as per RDSO specification no. RDSO/SPN/192/2005 Version 1.0 with latest amendment, and special conditions of contract mainly consisting of Central processing equipment, Interfacing Equipment/ Relays as per RE requirements and hot standby with Dual VDU [two nos. of industrial grade high resolution VDUs (55" or higher size-4K) for operator console at central location. Scope of supply against this item includes all the indoor equipments necessary for successful functioning of EI system, mainly consist of but not limited to following: \n1. Microprocessor equipment.\n2. I/O cards with card cage and motherboard.\n3. Power supply cards for EI and Object Controllers.\n4. All types of connectors and couplers as required.\n5. Modems and optical switches as required for communication between two EI equipments over OFC. \n6. DELETED\n7. Industrial grade PC & VDU for operator interface.\n8. Maintenance Terminals (PC & VDU as maintenance console-42" ( Industry standard PC ) along with counter box .\n9. All types of relays required for interfacing, Interconnecting cables and jumper wires, object controllers \n10. Relays and timers required for system changeover circuit. \n11. ECRs suitable for LED signals.\n12. DC-DC convertors (input voltage 110 V DC and output voltage as required) item1 1 System
3 3 13. All types of indoor wires as required.\n14. All types of indoor terminals and fuses as required except terminals for main CTR.\n15. Racks for mounting EI equipments and interfacing relays.\n16. Termination rack for indoor cables.\n17. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required.\n18. Softwares used for designing, configuration, maintenance, data logging and fault diagnosis of EI system. \n19. Protective devices like lightning protectors for DC and AC supplies, isolator/convertor for serial communication etc. \n20. Documents and manuals as per RDSO/SPN/192/2005 para 10.1 in three sets. \n21. Ring Earthing and EMI shielding of EI room. \nNotes: \nThe optical fiber connectivity with fiber management and diagnostic analysis system shall be provided to connect EI with SM room PC terminal. power supply arrangement required for the EI should be arranged by the tenderer. All interface relays for EI shall be supplied by tenderer. \nVariation in Bits and variation in number of routes upto (+) 20% shall have no cost bearing. For further variation (above 20%) of routes, cost will be recovered on prorata basis for % of routes increased. \n
4 4 This provision of hot-standby arrangement must have the supply, installation and commissioning of associated cards for the above arrangement such as communication card, synchronization card and others cards as required with supply & installation of supporting software and drives, etc. Also Optical Fiber link with loop back , dual DC-DC Convertor Input voltage 110V DC and outpt voltage as required shall also be provided. . Minimum requirement of Embedded PC for EI shall be as per RDSO TAN no. STS/E/TAN/3007 dated 2.11.12 (General requirement at enclosed in Technical Specifications).
5 5 Supply of all spares to the extent of 10% of that supplied against iabove itemsubject to minimum of one, for the cards/modules,connectors /couplers, fuses & relays. used in the EI system . It shall include spares for all type of LEDs, Buttons & Dominos used in control& Indicaton panel. Item-wise details of spares to be supplied with unit rates should be listed out by the tenderer along with offer. item4 1 System
6 6 Supply of Laptop based work station for data inputs & configuration, simulation and functional testing, diagnostics, trouble shooting and commissioning of EI system, complete with necessary softwares preloaded. item5 1 No.
7 7 Supply of Instruments / Tool Kits for EI*
8 8 Tool kits and Measuring Instruments for Technicians /Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer. \n\n* Above items includes suitable cabinet for storing tools to ensure longer life. item7 1 Set
9 9 Supply of Networked Data Logger for monitoring status of important relays, complete with processor module to monitor 512 digital and 32 analog inputs as per spec. IRS:S-99/2006 or latest RDSO specification including CMU, power supply of adequate capacity, battery, modems and fault diagonostic software for failure analysis, President rack of suitable size. It should have port for E1 CONNECTIVITY for sending DATA to control office .This includes\n item8 1 Nos.
10 10 Supply of one no. composite computer-printer table,UPS and Printer and one no operator chair.
11 11 Supply of Interconnecting cable between Contacts and Datalogger - this can be either 60/40 indoor cable or jumper wires as per IRS:S-76/89 or latest RDSO specification as per requirement\n
12 12 Supply of Interconnecting cable between CMU and Datalogger.
13 13 Note : Data loggers shall be provided at central EI as per the instructions of engineer in charge. Data logger should confirm to clause 5.15 of RDSO/SPN/192/2005 or latest & data logger Spec.IRS.99/2006 or latest. Modems required for networking of data logger shall be supplied by the contractor. Networking shall be preferably through E1 modems. The data logger shall consists of protocol converters and adequate capacity of digital and analog inputs. Networking of Data logger to the control room shall be done by Contractor. A separate PC of approved specification with 80 column dot matrix printer/laser jet printer shall be provided for each data logger as per the approved specification. The data logger PC shall be separate, it shall not be combined with any other PC of VDU or Maintenance Terminal PC. The RTC of data logger should be updated/ synchronized with EI systems and it shall be possible to log the events in chronological order in case of use of either single/multiple EI with Data logger. The data logger shall be inspected by RDSO.
14 14 In case of EI installation, this datalogger is for logging events outside of EI and full digital input must be supplied. Interface connection with EI is part of EI. The datalogger will transfer its own data along with EI data to central monitoring unit by using E1 connectivity.
15 15 Supply of Hard & soft copy (6 copies as built ) of following indoor drawings for RITES/ Rly approval including one copy on good quality 7.5 micron polyster film: this includes expenses for checking/rechechecking/ obtaing appovals from Railways /RITES .The also includes supply of two sets of drawings for checking, approval and corrections thereon as suggested by RITES/Rly) & threater supply of 2 copies for testing copy & 2 copies as costruction copy.RITES shall make available Schematic SIP.Contractor to Prepare and submit SIPs and other Drgs as per concerened Rly practice and get its approval from railways,if requiered- \n(i) Signalling Interlocking Plan (as per Rly practice)\n(ii) Selection table, \n(iii) Vital & non-vital I/O Bit Chart, \n(iv) EI configuration diagram, Equipment layout plan, Relay disposition chart. \n(v) Front plate diagram of control/indication panel. \n(vi) Application logic \n(vii) Interface circuit with contact analysis. \n(viii) Equivalent circuit of application logic. \n(ix) Prepration & supply of SWRD (station Working Rule Diagram). \n(x) Prepration & supply of station working Rule.\n item14 1 Job
16 16 RELAY RACKS, TERMINAL BLOCKS, FUSES
17 17 Relay Rack assembly complete with fixtures for mounting point group relays/'Q' style relays in Relay or EI Hut with all accessories like scaffolding, ladder, runway for indoor cables/wires alongwith mounting arrangement as per drg. No. RITES/SIG/GEN/006A-07. item16 1 No
18 18 Main cable termination rack complete assembly with hylam sheet , screws, nuts & bolts, scaffolding ladders for cable wires alongwith mounting arrangements etc. as per Drg No.RITES/SIG/GEN/052A-09. item17 1 No
19 19 Non deteriorating type fuses as per IRS-S-78/92 with latest amendment. Rating 2Amps-65%, 4Amps-25%, 16Amps-10%. item18 1 No
20 20 Fuse block made of PBT as per Specn.No. IRS-S-75/2006(Rev.2) and Drg.No. SA-23748 (Alt.4) item19 1 No
21 21 Multi channel Earth leakage detector of 8 channels (AC/DC) as per RDSO/SPN/256/2002 along with insulation resistance meter, remote indication & buzzer in SM room at all stations. The tenderer should submit three years warranty certificate along with supply of material. item20 1 No.
22 22 ARA terminal 6 way, made of PBT as per drawing No. 23756 (adv.) Alt3 or latest confirming to RDSO specn. No.IRS-S-75/2006 (Rev.2 or latest) with latest amendment item21 1 No
23 23 ARA terminal (1 way) made of PBT as per drg.no.23746 & specn. No.IRS-S-75/2006 (Rev.2 or latest) with disconnection link as per Drg.SA-23746 Or 23745(Alt-5). item22 1 No
24 24 Supply & fixing of 2-conductor disconnect terminal block for test & measurem ent front entry suitable upto 2.5 sq mm conductor similar to model No. 280-870 of WAGO make. item23 1 Nos.
25 25 Supply & fixing of End plate similar to model No 280-371 of WAGO make . item24 1 Nos.
26 26 Supply & fixing of Din 35 Rail of dim ension 35mm x 7.5 mm 1mm thickness unslotted similar to model No 210-229 of WAGO make. item25 1 Nos.
27 27 Supply & fixing of End stop for Din 35 Rail 10mm wide similar to model No 249-117W AGO make. item26 1 Nos.
28 28 Supply of hylem/decolam sheet 6 mm thick & size 2400 mm and 600 mm of colour approved site incharge item27 1 Nos.
29 29 Supply and installation of maintenance free single earthing for IPS/DAC Equipment. All the materials required shall be supplied by the contractor including cadmium bronze wire rope for connection between earth electrode and equipment box. Resistance value shall be less than 1 ohm. item28 1 No
30 30 FURNITURE ITEMS
31 31 Office Chair of continuous arms having cushened seats and rest T.W. Arm rest size 36" x 21" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled "Indian Make". Godrej/Jalaram Make. 1 Nos.
32 32 Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys. Olive green colour Godrej Make. item31 1 Nos.
33 33 Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, Godrej Make. item32 1 Nos.
34 34 Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black.The chair has plastic caned seat and back on 25 mmround tubular frame. The base is of pressedsheet metal. Godrej/ Allwyn/ Chandan/ Khira make.Width 700 mm,Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, Colour Grey. item33 1 Nos.
35 35 4 door book case of size 1675x840x308mm Godrej make item34 1 Nos.
36 36 POWER SUPPLY/BATTERIES
37 37 SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/SPN/165/2012 with latest ammendment alongwith LMLA Battery Bank of 300AH & Battery rack (Configuration based on RDSO dwg. no. SDO/IPS/PI-10L/005 and SDO/IPS/PI-6L/RE 002 and site specific load requirement, shall be put up to RITES with load calulation sheet and approved by employer/consultant before supply) item36 1 No.
38 38 DG set 15 KVA, 230 V AC single phase with only Mahindra or Kirlosker or Cummins or crompton or similar quality alternator make , two wall mounting control panels (one main and one subsidisry for remote operation) to start generatoe by push button battery operated- 15KVA to IRS-S-69/86. This includes a) Supply of batteries 12v, 200AH 1 No. with each DG set b) Suitable Battery cahrger for charging this battery c) 60 liter diesel tank 1 No.
39 39 Supply of Automatic change-over unit for change-over between three power supply sources of 63 A/230 volts,single phase with provision of manual bypass arrangement. Drawing shall be got approved by Engineer Incharge. item38 1 No.
40 40 Supply and installation of Demineraliser plant of standard make of capacity 65 ltr. per hour approx. This includes all the pipe connections from the water source to unit and also to the collection unit. item39 1 No
41 41 SIGNALING INDOOR CABLES/WIRES
42 42 Cable unarmoured PVC insulated multi core unseathed with plain annealed copper conductor as per colour coding scheme of Raliways in accordance with Specification No: IRS-S-76/89 with Amendement -2 or latest-
43 43 60 C x 1 mm dia. item42 1 km
44 44 Cable unarmoured PVC insulated, unseathed with plain annealed high conductivity 650V grade copper conductor as per colour coding scheme of Raliways in 100 meter coils, confirming to RDSO Specification No: IRS-S-76/89 with latest amendment-
45 45 16 x 0.2 mm.(Grey) item44 1 Coil (100M. Each)
46 46 3 x 0.75 mm. (Red & Black) 1 Coil (100M. Each)
47 47 1x6 sq mm. (multistrand flexible wire) (Red & Black) item46 1 Coil (100M. Each)
48 48 1x10 sq mm. (multistrand flexible wire) (Red & Black) item47 1 Coil (100M. Each)
49 49 OUT-DOOR
50 50 SIGNALING CABLES
51 51 PVC Insulated Armoured, Unscreened, Underground Railway Signaling Cable as per specification No.IRS:S-63/2014(Rev.4.0).
52 52 2 core x 2.5 sq.mm. item51 1 Km
53 53 6 core x 1.5 sq.mm. item52 1 Km
54 54 12 core x 1.5 sq.mm. item53 1 Km
55 55 19 core x 1.5 sq.mm. item54 1 Km
56 56 24 core x 1.5 sq.mm. 1 Km
57 57 30 core x 1.5 sq.mm. 1 Km
58 58 PVC insulated armoured, unscreened, undergroung Power cable (Aluminum conductor) confirming to IRS-S:63/2014(Rev 4.0) or latest & IS 1554 (Part-1) - 2 core x 25 sq .mm, 1 Km
59 59 Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/2005 (Ver.-1) (Amd. 1 to 5) with latest amendment having 0.9 mm dia copper conductor. 1 Km
60 60 ELECTRIC POINT MACHINE
61 61 Electrical point machine, IRS heavy duty non-trailable rotary locking type 143mm throw to operate on 110V DC complete with lock & detector slides and cable termination box as per IRS:S-24/2002 & IRS-S-37/82 with latest amendment, Drg. No. S-10910 for motor Assembly Drg. No. S-10800. (One No. tool kit will be supplied for installaton for a group of 08 Nos of point machine) item60 1 No
62 62 Point Machine ground fitting set as per RDSO Drg.IRS 3361-62 (IRS type) 1 Set
63 63 Insulation for gauge tie plate for BG as per IRS-S-40/84 and drg.No.T-10372, T-10368, T-10371 each set comprising of :\na) Insulating plate - 2 No.\nb) Bushes - 6 No.\nc) Washers - 12 No. 1 Set
64 64 Insulation for 'P' bracket for point machine as per Rly. design each set comprising of :\na) Channel side plate LH - 2 No.\nb) Bushes - 4 No.\nc) Washers (Nylon)) - 4 No. \nd) Washers (Iron) - 4 No. 1 set
65 65 TRACK CIRCUITS
66 66 Track feed battery charger 110 V AC / 2 - 6 V DC - 5 amp charging rate suitable to charge 1, 2 or 3 cells of 80 AH, to IRS-S-89/93 Amendment-2 or latest. 1 No
67 67 Track feed variable resistance (with phenolic moulded base) 30ohms to suit RDSO drawing number SA20166/M/adv Alt-1, IRS: S-23. item66 1 No
68 68 `B' type choke as per specification No.IRS-S-65/83 Amndt -1 or latest. item67 1 No.
69 69 Fibre glass Track Lead Junction Boxes as per Drg. No. RITES/SIG/GEN/42-2008 complete with one way terminal block and 450 mm long, 25mm dia plastic HDPE pipe. termination of signalling cable for the use of track circuit. item68 1 No.
70 70 Low Maintenance secondary cell of 80AH. Confirming to RDSO Spec. No. IRS:S88/2004 (A) Amndt.-1 or latest. 1 No
71 71 Channel Bond pin single groove. Tinned or Zinc coated 7mm dia. As per RDSO specn. No. IRS:S-17/75 with Ammendment 1 for bonding track ckt. Wires. 1 No.
72 72 G.I.Bond wire soft 8 SWG for bonding resistance -132 ohm/Km. at 27 deg.C. to IS-279 1 Kg.
73 73 Nylon Insulated rail joint complete as per specn.IRS-S-40/84 and RDSO's Drg.No SA-22101 (alt-6) for 52 kg rails /SA-22171 (alt-2) for 60 Kg rails/ SA-22191 (alt-2) for 90R rails comprising of :\na) Channel side plate LH -2 No.\nb) Channel side plate RH -2 No.\nc) End post - 1 No.\nd) Insulating plate. - 4 No.\ne) Bushes - 8 No.\nf) Long fish bolts. - 4 No. 1 No.
74 74 BLOCK INSTRUMENT
75 75 Block Proving By Axle Counter (BPAC) using UFSBI (For double line and single Line) conforming to Specn. No. IRS: S-105/2012 (Ver.0 or latest) for Single Line and Double line operation consisting of the following: \na) Universal Fail Safe Block Interface (UFSBI) conforming to Specn. No. IRS: S-104/2012 (Ver.0 or latest) - 2 Nos,\nb) SM Panel (RDSO Drg. No. RDSO/S/32019) with accessories -\nc) Relay rack with double locking & sealing arrangement. Wiring diagram as per RDSO Drg. No. - RDSO/S/32020 - 2 Nos. Relays to be supplied with prewired relay rack QN1 = 44 nos., QL1=4 nos., QNA1=12\nd) Block Telephone RDSO Spn. No. RDSO/SPN/191/2005 = 2 Nos. item74 1 No.
76 76 SIGNALS
77 77 Colour light signal (2 aspect) complete set as per drg.No.SA - 23003 A/M (adv.) alt.9 & Specn. IRS-S-26/64 consisting of the following items : item76 1 set
78 78 Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.
79 79 Signal base Cast Iron 140 mm dia. to drg. No. S-2011/M.
80 80 CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.
81 81 Colour Light Signal Unit 2 Aspect complete with out signal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
82 82 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78
83 83 Offset bracket of main signal for 140 mm dia post to 23080 (adv) alt.1
84 84 Colour light signal (3 aspect) complete set as per drg.No.SA23002 A/M (adv.) alt.9 & Specn. IRS-S-26/64 consisting of the following items : item83 1 set
85 85 Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.
86 86 Signal base Cast Iron 140 mm dia. to drg. No.S-2011/M.
87 87 CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.
88 88 Colour Light Signal Unit 3 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23002 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
89 89 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment.
90 90 Offset bracket of main signal for 140 mm dia post to 23080 (adv) alt.1
91 91 Colour light signal (4 aspect) complete set as per drg.No.SA23001 A/M (adv.) alt.9 & Specn. IRS-S-26/64 consisting of the following items : item90 1 set
92 92 Supply of CLS post 140mm dia. 4.5 M long to specification IRS.S.6.81or latest (as per site requirement).
93 93 Supply of Surface base 140mm dia.post to suit CLS as per drg.S.2011/M
94 94 Supply of CLS ladder set complete with staging, supports, signal number plate, cast iron ladder base to suit 4.5 Metre post as per drg.no.SA. 23153.S.2033.
95 95 Colour Light Signal Unit 4 Aspect complete with out signal transformers,lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23001 A/M (Adv.) alt.9 & Specn. IRS-S-26/64.
96 96 04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/M & IRS-S-10/78 with latest amendment.
97 97 Junction type route indicator 2 way complete without lenses, lamp holders and lamps. to IRS-S-66/84, IRS-S-23/86 with RDSO drg.No.SA-23402 (Adv.) alt 2 or latest. item96 1 Nos.
98 98 Independent shunt signal complete having following items. item97 1 set
99 99 Shunt signal post 90 mm dia 1m long to IRS-S-6/81.
100 100 Shunt signal surface base 90 mm dia drg.No. S-2011.
101 101 Position light shunt signal unit without lamp holder unit, lenses & lamps to RDSO drg.No.SA-23840(adv.) ALT-2.
102 102 04 nos. anchor bolts for shunt signal (305mm. X 50mm. X 20mm.) to drg.No.SA-110 A/M.
103 103 Offet bracket for 90 mm dia drg No. S-2011
104 104 Shunt signal dependent type drg No. SA-23840 (adv.) Alt.-1 and S-23845 (adv.) with offset bracket 3½'' dia. to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders. item103 1 set
105 105 Calling on signal unit position light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S:10/78, IRS-S:26/64. 1 No
106 106 LED for Main aspect signal lighting unit conforming to Indian Railway chromatically standards and RDSO Specn. No.RDSO/SPN/153/2011 REV.4.1 to use with AC LED ECR. (This item includes supply of current regulator, Health monitoring unit, audio visual alarm, fuses and other accessories required for fixing). .
107 107 For Red aspect 1 No
108 108 For Yellow aspect item107 1 No
109 109 For Green aspect item108 1 No
110 110 LED signal lighting unit for Junction Type route indicator conforming to Indian Raiway chromaticallity standards & RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 with latest amendment. (This item includes fuses and other accessories required for fixing) item109 1 Nos.
111 111 LED signal lighting unit for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 with latest amendment. (This item includes fuses and other accessories required for fixing) item110 1 No.
112 112 LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/SPN/153/2011 REV.4.1 with latest amendment. (This item includes fuses and other accessories required for fixing) item111 1 Nos.
113 113 Supply of hand cuff (universal) locks with key (one key for every 4 locks). item112 1 No
114 114 Signal number plate as per drawing no. RITES/SIG/GEN46-08 3mm. thick white laminated MS sheet shall be used. Letter shall be written in black on yellow background. 1 No.
115 115 Supply of various types of markers as
116 116 P markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'P' shall be written in black. item115 1 No.
117 117 C markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'C' shall be written in black. item116 1 No.
118 118 G markers as per drawing no. RITES/SIG/GEN45-08 circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'G' shall be written in black. item117 1 No.
119 119 Supply and fixing of description boards made of ply 6 mm thick with laminated trouble shooting chart fixed on it and 1"x1" wooden batten fitted all round on the rear as per instruction of the Engineer. All the materials to be supplied by contractor. item118 1 Square mtr.
120 120 Supply and Installation of Goods Warning board complete with all fittings: Rectangular board of size 600mmx1000mm with angle iron for fixing. Yellow retroreflective tape on black background. item119 1 No
121 121 Stop board / Shunting Limit board/Block Section Limit Board 40cmx80cm rectangular made of 3mm thick MS sheet with fixing angle iron. "STOP"/"SHUNTING LIMIT"/"BLOCK SECTION LIMIT" should be written with red retroreflective tape on white background. item120 1 No
122 122 APPARATUS CASE
123 123 Steel Appratus case Full, complete with `E' type lock & keys to drg. No.RITES/SIG/GEN/043-09. The E type lock shall have ward No. 32. item122 1 No.
124 124 Steel Appratus case Half complete with `E' type lock & keys to drg. No.RITES/SIG/GEN/044-08. The E type lock shall have ward No. 32. item123 1 No.
125 125 RELAYS
126 126 Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be ABDFH. item125 1 No.
127 127 Relay, AC immune, plug-in type, style ‘QTA2’, neutral track, 9 ohms, 2F.1B contacts, front and back contact metal to carbon, complete with plug board, retaining clips and connectors confirming to BRS-939A, BRS-966 (Appendix F2), IRS-S-34 & IRS-S-23 (as applicable). item126 1 No.
128 128 Key lock relay with 1 No. K 50 (N) relay to operate on 24V DC, 4F/4B contacts confirming to IRS:S-46, IRS:S 34 & IRS:S 23 (as applicable) and firm's specification. Crank handle keys to be provided with different ward combination for each crank handle group and matching sockets on the point machines. item127 1 No.
129 129 Supply and installation of KLCR box (one box to accommodate 2-6 Nos. of key lock relays) item128 1 No.
130 130 Supply and fixing of Crank handle Box 1000 x 250 x 150mm made of 12 mm thick Teakwood with a glass front and padlocking and sealing arrangement as per standard practice. Pad locks to be supplied by contractor, all materials i.e. Teakwood, handle, hinges, Glass sheet of 3mm thick to be supplied by the contractor. Box to be polished and description to be painted as per instructions of Engineer in charge. item129 1 No.
131 131 Relay, point contactor unit along with base plate, Non-AC Immune, plug-In type and capable of controlling Electric point machine operating on 110V DC conforming to IRS:S 46, IRS:S 34 & IRS:S 23 with latest amendment (as applicable) and firm's specification. \nThe unit shall consist of N/R relay (Double wound DC neutral line relay), XR relay (DC Neutral relay). W(N)R/W(R)R - mechanically interlocked relay & WCR (Heavy duty contactor relay with 16 Ampere breaking capacity). All the above relays shall be mounted on pre-wired base plate. item131 1 No.
132 132 Relay, AC Immune, plug-in type, Style "QNA1K" 24 V/1000 Ohm conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable). The interlocking code for this unit shall be CDEKY. item132 1 No.
133 133 Fail-Safe Electronic timer, 24 V DC, 120 sec as per RDSO specification IRS: S-61/2000 with latest ammendments. item133 1 No.
134 134 Fail-Safe Electronic flasher device as per RDSO spec. RDSO/SPN/173/2002 with latest ammendments. item134 1 No.
135 135 CIRCUITS & DRAWINGS
136 136 Design, prepearation & supply of Six (06) hard copies of each documents along with soft copy for the mention below alongwith original tracing on a standard 7.5 microne polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES) item136 1 station
137 137 Cable route plan
138 138 Location box details with location wiring diagram
139 139 Cable termination details
140 140 Cable corage plan
141 141 C.T. Rack details
142 142 Track bonding plan
143 143 Cable jointing details
144 144 Signal lighting circuit
145 145 Circuit diagram for LC Gate No.
146 146 Gate Working Rule with Gate Signal Diagram
147 147 TOOL KIT
148 148 Supply of maintainer's tool kit (Gedore or Taparia make) consisting of items as per list below:-\ni) Insulated Screw Driver 12" -2 No.\nii) Plier electric 8" - 2 Nos\niii) Plier cutting 8" - 2 Nos\niv) Stripper - 1 No.\nv) Nose Plier - 1 No.\nvi) Spanner Set-1 No\nvii) Spanner double ended -1 No \nviii) Hammer Ball piece (medium) - 1 No\nix)Soldering Iron 125 watt-1 No\nx) Soldering Iron 65 watt - 1 No\nxi) Multimeter digital (standard make) - 1 No.\nxii)Tool Box of 18" size similar to VIP or Alfa make item148 1 Set
149 149 PROTECTION ITEMS
150 150 Non-Split HDPE DWC pipe Confirming to IS:14930 part-II, with threaded coupler, of following sizes:
151 151 Size : 120 mm outer dia. and 103 mm inner dia. item151 1 Mtrs.
152 152 Size 200mm outer dia and 175 mm inner dia item152 1 Mtrs.
153 153 Half split double wall corrugated (DWC) pipe of HDPE in 2/3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrengement.
154 154 Size : 120 mm outer dia. and 103 mm inner dia. 1 Mtrs.
155 155 Size 200mm outer dia and 175 mm inner dia item155 1 Mtrs.
156 156 Supply of Galvanized Iron pipe 100 mm dia `B' class with end clamps OR Galvanised Iron pipe 100 mm dia `B' class,(6 Mtr. Length) as per specn.No.IS-1239, part 1 / 1990. along with threaded coupler (Perforated with 6 mm holes) item156 1 Mtr
157 157 Supply and fixing of FRP cable route marker as per drg. No. RITES/SIG/GEN/048-08. item157 1 No
158 158 Supply and placing of second class bricks/Fly Ash brick size 225mm x 112mm x 75mm (9 bricks per Mtr.) after laying of cable & refilling the trench by loose soil of 100mm to over cable. item158 1 No.
159 159 Supply of straight through heatshrink cable joint for underground signalling cable complete as per RDSO Specification No.IRS:TC-77/2012 (Rev.3.0) amnd.-1 or latest. 1 No.
160 160 Supply of Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight through as RDSO specn. No.IRS-S-TC-77/2012, (Rev.3.0) amnd.-1 or latest. item160 1 No.
161 161 Supply of 'B' & 'C' class surge protection system consisting of lightning current arrestors two nos. of class 'B' for connecting between line & neutral and neutral & earth & class 'C' for single phase power supply in TT network, housed in a polycarbonate transparent box with IP 65 protection, all conforming to RDSO spec. No. RDSO/SPN/144/2004 or latest. item161 1 Set
162 162 Supply & fixing of Fire Extinguisher. Necessary nuts, bolts,, clampls, etc shall be supplied by the contractor. item162 1 No.
163 163 Supply and Installation of Earth electrode assembly and concrete encloser with cover as per drg. No. RITES/SIG/GEN/013-98 and RITES/SIG/GEN/014-98 respectively. This includes providing connection to location box, signal unit, block instruments, cables etc. through GI wire 8 SWG suitably sparted on MS flats size 30 x 3 mm as per drg.No. RITES/SIG/GEN/015-98, RITES/SIG/GEN/016-98 & RITES/SIG/GEN/017-98. This includes:\n(i) Diging of pit in earth 3 m deep.\n(ii) Casting of cement concrete enclosure as per drg.No.RITES/SIG/GEN/014-98.\n(iii) Soil treatment as per standard practice involving supply & pouring of salt & charcoal.\n(iv) Connecting the equipment through earth lead wire & soldering.\n(v) Supply of cement, wiring material & soldering material.\n\n\n item163 1 No.
164 164 Supply, Installation, testing and commissioning of Hi wall split AC of 1.5TR capacity suitable for single phase 50 Hz AC 230V comprising of following items complete in all respect for achieving successful operation of the unit:\ni) Outdoor Conditioning Unit\nii) Indoor Evaporative Unit\niii) Interconnecting refrigerant piping with insulation, drain pipe, charge of refrigerant and oil etc. The unit should include refrigerant piping, power cabling and drain pipe up to 8 running meter.\niv) Automatic voltage controller/Voltage Stablizer of appropriate rating complete as required.\nv) Iron stand of appropriate size for mounding outdoor unit with foundation/grouting as required.\nvi) All required safety and operational control 1 set
165 165 Supply of Electrically operated lifting barrier assembly each consisting of 2 Nos. of electrically operated lifting barriers complete with all accessories as per RDSO Specification no RDSO/SPN/208/2012 Version-2.0 or latest RDSO specification, boom in 4 section of 8 feet long each along with Gate control panel & indication panel on sheet metal fabricated box , supply of power contactors, flasher relays etc. Approval for Operating voltage (110V) of the boom , type of Boom locking etc has to obtained from Engineer incharge. Any extra material required for commissioning , to be supplied by the contractor. It also includes Dual tone warning bell (hooter) with 20 Watt Horn and 15 Watt amplifier MUCONY TYPE or similar with operating voltage 110 V A/C - 1 set item165 1 No
166 166 TELECOM
167 167 Armoured Optical Fibre cable 24 Fibers as per RDSO specification No. IRS: TC: 55-2006 rev. 1 with Amdt. 1.1 1 km
168 168 Supply of 2 x 24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories of make TVSE R&M model No.1500- L 183- XX or Raychem make model.No.BPEO - Type 1-24F or 2179CS - 24F. item168 1 No.
169 169 Supply of Plastocrate pre-fabricated OFC jointing pits size 1 x 1 x 0.6 meter as per technical specification. item169 1 No.
170 170 Supply of Fibre Distribution Management System, 19" rack mountable for 2x24 fibre OFC with connector, patch cord & pigtails as per specn. No. RDSO/SPN/TC/ 37/2000 (Ver. 3) with latest amendment suitable for termination of 2x24 fibre OFC. item170 1 No.
171 171 Supply of Permananently lubricated HDPE pipe 40 / 33 mm dia. As per RDSO specification no. RDSO/SPN/TC/45/ 2013 Rev 2.0 or latest RDSO specification if any; suitable for armoured 24 fibre OFC cable including its accessories like plastic coupler, end plug, cable sealing plug and end cap etc as required for the OFC system based on survey report. item171 1 km
172 172 Supply of managed Expendable rack type STM-1 ADM L 1.1 as per Technical Spec. No. TEC GR No. GR/SDH-04/02 Mar 02 with amendment 1 , 2 ,3 & 4 or latest RDSO specification with STM-1 aggregate interface , 21 E1S (4 Numbers of 10/100 Base T Ethernet Port order wire) expandable upto 63 E1 capacity, simply by addition of EI cards, fully wired, cross connect granularity at VC-12, VC-3 & VC-4 level equipment with power supply unit, sub rack installation material and accessories manual etc.The equipment should be fully wired for its ultimate capacity and provide redundency for power supply and synchronisation ( model - TJ 100 MC1 ). This also includes Installation, wiring, testing, commissioning with original software, with all accessories & technical manual, etc. . The SDH equiment shall be RDSO/TEC approved. item172 1 No.
173 173 Supply of 2 Mb programmable primary digital Drop insert Multiplexer operating on 48 Volts DC complete as per specification IRS:TC 68/2012 with latest amendments applicable on the date of opening of the tender, with conference facility and other stipulations of tender document fully wired and equipped for 30 channels complete with power supply card, remote control, supervision facility and all other accessories, installation materials, manuals etc. item173 1 No.
174 174 It should have the facility to accommodate data interface card in multi drop mode and should be able to support card needed for video conferencing and ISDN. It shall also support NMS operations from local/remote locations. The Chassis shall support 4 E1 cards Nos.This item also includes the cost of supply, installation & commissionng of NMS software.
175 175 The MUX should be equipped with following :-
176 176 I) 2 wire/4 wire E&M cards for 4 circuits
177 177 II) Subscriber loop cards for 4 circuits.
178 178 III) 64 kbps omnibus/co-directional data interface card for 20 circuits.
179 179 Suppy of 48V, 50 amps battery charger for telecom use as per No.RDSO/SPCN/TL/23/99 (ver.4) or latest in N+1 configuration i.e. using 3 modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery. It shall be equipped with surge and lightening protection of class `B' and `C' the configuration shall be decided as per site requirement. 1 No.
180 180 Supply of maintenance free VRLA secondery cells duly charged of 48V 200 AH and each 2.0 V when fully charged 200 AH capacity alongwith accessories i.e. intersell connectivity links/float, 4 nos. insulators for each cell 24 nos. of cell per set as per RDSO Spcn.IRS/S/88/2004 amendment - 1 revision with latest amendments with cuitble steel/ hylam tray battery rack to install/house batteries. 1 sets
181 181 Supply of 19" covered rack (2.2m height min), vero president/Rittel make or similar with Glass front door complete with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with intergrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. 1 No.
182 182 Supply of hardware for NMS as per required specification including one no. Monitor 19" TFT and six nos. flash RAM type pen drive as per the specifications enclosed. NMS for SDH/STM and 2 Mb Mux shall be loaded in this equipment. 1 No.
183 183 Supply of of Optical domain reflectometer (OTDR), dynamic range 30db, as per the specification of model no .TFS 3031 with both the options of 1310 & 1550nm Of fibers of similar. 1 No.
184 184 Supply of Optical fibre tool kit with box of FIS INC USA make Part no. F1-0053 1 Set
185 185 Pocket fault locater of OFC to indicate cable point of loss (3-4 Kms. on multi mode & 5-6 Kms. on single mode) of FIS-INC, USA make or equivqlent. item185 1 No.
186 186 Supply of one Quad VF 2T transformer joint assembly of VF transformers 470:470/1120:470 as per IRS TC/76/2000 with ammendment - 1 or latest item186 1 No.
187 187 Supply of EC socket box as per RDSO spc. No.IRS: TC-42-87, amendment-1 or latest. 1 No.
188 188 Supply of 6-pin emergency plug & socket flat type as per RDSO spc.no. IRS:TC-42-87. item188 1 No.
189 189 Supply of DTMF 4 wire based Headquarters Equipment for Control circuits as per RDSO spec No.IRS.TC..60/93 (or latest) with power supply unit to suit RDSO Spec No.IRS.TC.72/97 (or latest) item189 1 No.
190 190 Supply, installation & commissioning of 4 wire DTMF way station Equipment as per RDSO specification No. IRS:TC:60/93 with Amnd. 4 or latest alongwith compatible way station telephone as per RDSO Spec. No. IRS:TC:38:97 with Amnd. No. 1. Item includes their, installation, testing & commissioning with contractor's all materials required for installation. 1 No.
191 191 Supply of 4 wire DTMF Control Telephone spec.IRS-TC-38/97 with Amendment-1 or latest Tummala make or similar) 1 No.
192 192 Supply of Desk type electronic Magento phones as per Spec. No. IRS(S)TC-79/2000 with latest amendments.. 1 No
193 193 Supply, installation & commissioning of Power supply for DTMF equipment/Selective calling telephone to RDSO spec. IRS:TC:72:97(or latest) with 12v 7AH battery 1 No.
194 194 Supply of Desk type 2 wire DTMF, 12 way selective calling calling group telephone as per RDSO specification no IRS:TC:80:2000 (Set of 12 telehones) 1 Set
195 195 Supply of 2 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 item195 1 km
196 196 Supply of 5 pair 0.63 mm PVC insulated Unarmoured Telephone cable as per Technical specification of GR/WIR 06/03 March-2002 item196 1 km
197 197 Supply of 10 pair 0.63 mm Jelly filled Armoured Telephone cable annealed bare copper conductor, solid polyethylene insulated and sheathed as per technical specification GR/CUG-01/03 August- 2003 1 km
198 198 Supply of 10 Pair copper conductor size 0.63MM PIJF UG Cable as per RDSO Spec No.IRS TC 41/97 or latest 1 km
199 199 Supply of 20 Pair copper conductor size 0.63MM PIJF UG Cable as per RDSO Spec No.IRS TC 41/97 or latest item199 1 km
200 200 Suply of 20 pair krone type DP box with locking arrengement 1 No.
201 201 Suply of 50 pair krone type DP box with locking arrengement 1 No.
202 202 Supply of switch board cable 20 pairs 0.5mm dia item202 1 km
203 203 Supply of Krone Tool item203 1 No.
204 204 Supply of Thermo Shrink Jointing Kit For Jointing Underground PIJF Cable as per spec. RDSO/SPN/TC/57/2015 (Rev.1) item204 1 No.
205 205 Supply of VHF transreceiver set simplex, 25 watt similar to Motorola model no. GM 338 with suitable antenna attached to 12 feet support pipe and 30M RF cable. This shall also include the Power supply for 25W radio (12V/15Amp) with Sealed maint. Free battery (65AH) and one BNC to VHF adapter. This item shall comply to technical specification para.-16.0. 1 set
206 206 Supply of VHF mobile transreceiver simplex, 5 watt similar to Motorola model no. GP 328 with rechargeable battery. This will include battery charger, one rechargeable spare battery and two spot frequencies for 5W and 25W radios. (supplier shall obtain spot frequencies from WPC). This item shall comply to technical specification para.-16.0. 1 set
207 207 MISCELLANEOUS
208 208 Supply of true RMS Digital Multimeter (Fluke Make Model -289 or similar) 1 No.
209 209 Supply of Track hand- Drilling machine with all fixtures and 6 nos. 9/32'' drill bit for track bonding for installation. 1 No
210 210 Megger (Insulation Tester) with effective measurement range of 0.02 - 20 M ohms, Digital, Motwani make Model D-266. item210 1 No.
211 211 Hydrometer, exide make or similar for measuring specific gravity of battery graded acid with mounting stand in location boxes. Consignee inspection under manufacture certificate. 1 No.
212 212 Supply of Battery Tester item212 1 No.
213 213 Supply and installation of Electronic Rat Repellant of reputed make working on sonic and ultra sonic frequencies as per instructions of site Engineer. item213 1 No.
214 214 Cable Route Locator Kit of C-Scope International UK comprising of cable avoidance tool SVG, Digital Signal generator, Signal Clamp. Accessory, Carry Bag it will comprise of following: (i) ST-CAT 33 XD cable avoidance tool CAT 33 XD: Digital underground cable & pipe location reciever & cable avoidance tool that provide location of metallic cables such as signalling cables, armoured OFC, power cable etc. when used in conjuction with the SGV signal generator, the cable avoidance tool converts to a cable route tracer that route traces metallic U/G pipes & cables. pipe etc, in generator mode. Provides depth of cable being traced. (ii) SGV Digital signal generator for conductivity or inductively injection signal into U/G metallic utility pipe or cable to the traced. 1 No.
215 215 Schedule- B Execution Signalling
216 216 EI System
217 217 Installation, Testing and commissioning of complete signalling system integration with outdoor gears ,slotting, adjacent station Bolck instruments etc at the staion as a whole. Wiring, programming, Bell test,Site acceptance test (SAT) of Centralised panel , Screening arrangementnt with Copper strips ,lightening- protection arrangement,Earthing wiring etc as per Railways practice . This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/mesonary works, termination of cables with lugs/connectors, painting/lettering on relay rack/termination rack are to be done by the contractor. . Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter,etc. shall be provided by contractor at his own cost. testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and neccesary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.It also includes provision of temporaty tents/Huts,arranging lights,Chairs & tables, provision of temorary telphones,snacks/drinking water for NI staff round the clock at site etc as reqired duing the NI period in Railways.\nNote: 1. Variation in Bits upto (+) 20% shall have no cost bearing. 1 System
218 218 Installation, Wiring ,testing and commissioning of Centralized monitoring of Data loggers at Control Office by linking all Road side dataloggers including conventional and EI Data loggers complete along with accessories with Contractor's own material. This includes programming of data logger for fault diagnostic in suitable structured language in consultation with Rly. 1 No.
219 219 Training for O&M Staff
220 220 Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking system including provision of hard copies of course modules for each trainee. 1 Man month
221 221 Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs of Electronic interlocking system including provision of hard copies of course modules for each trainee. 1 Man month
222 222 Training of Technician/Jr. Engineers in installation, Testing, commissioning & trouble shooting of MSDAC system including supply of hard copies of course modules for each trainee. 1 Man Month
223 223 Training of Sr. Engineers/Managers in installation, Testing, commissioning, trouble shooting and Repairs of MSDAC system, including supply of hard copies of course modules for each trainee. 1 Man Month
224 224 RELAY ROOM
225 225 Erection of cable termination rack. Clamping of cables, Numbering of cables with engraved aluminium strips, Supply of nuts & bolts, MS clamps & cement for massonary works.This will also include paintng of Cable/core particulars for each trminationwith contractors own paint.The place for erection of Termination Rack shall placed as decided by Site Engineer 1 No
226 226 Installation of relay rack assembly complete alongwith wall supports, sccaffolding, ladders/runway for cables, relay base plates etc. This includes Fixing of Relays with retaining clips, Fixing of disconnecting type terminals/ARA Terminals, PBT Fuse bases( supplied under Schedle A,) , termination of cable cores/wires, Supply of nuts & bolts, MS clamps & cement for massonary works.:This will also include Painting of Relay description on the front side and back side of the Relays as per instruction of site engineer 1 No
227 227 Wiring of relay base plate to other base plate as per approved diagram & soldering after testing. It includes numbering of wires.This work also includes bunching and dressing of all cables/wires. 1 No.
228 228 Installation, wiring, testing and commissioning of multi channel earth leakage detector including supply of mounting arrangement. 1 No.
229 229 Necessary arrangement for manufacture, transportation & installation of station masters console for fixing telephones & other equipments as per instruction of Engineer incharge. This includes : All materials like 25mm thick hylum sheet etc. required for the above including sundry items like bolts & nuts, screws, MS angle / flat shall be supplied by the contractor. 1 Job
230 230 POWER SUPPLY/BATTERIES
231 231 Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system, at station as per technical specification and instructions given in Installation manual of OEM. Approval for installation drawings shall be obtained from project consultant before installation. This includes supply of all materials required for installation and initial charging of low maintenance Lead-Acid batteries (3 cycles). 1 System
232 232 Installation of DG set, testing and commissioning, at Tanda Inplant. This includes casting of vibration free foundation, installation of ASM panel, outlet for exhaust panel, laying of power cable from DG room to ASM room for remote operation of DG set and wiring of DG set of ASM panel, laying of cables/wires should be carried out in HD PVC channel/ conduit pipe. This includes cost of all mateials required for installation except DG set and perASM panel. Wires/cables as extant practice on Railways and instruction of Engineer at site. 1 Per KVA
233 233 Installation,wiring,testing & commissioning of LT power panel with auto change-over. This includes fixing of power panel.termination of LT cables & fixing of Auto-change-over management and its wiring and supply of MS angle,nuts & bolts etc. 1 Nos.
234 234 Installation, wiring and commissioning of 48 volt battery set fully charged, battery chargers and surge supressor Yard. This includes supply of 51 strand of 0.75 mm each strand paramite battery wires in two colours of appropriate length, connection of power supply to the equipments through suitable casing caping as per the instructions of Engineer incharge of Railway at site. This also includes supply & installation of necessary fuses, provision of teak wood planks stands (to be approved by railway before supply) of suitable size for resting of batteries, battery chargers & ultra isolation transformers. All the material required for installation of this item shall be supplied by the contractor. NOTE- Before installation of Batteries contractor has to ensure that batteries are fully charged. 1 Station
235 235 Installation, testing and commissioning of battery charger & maintenance free LMLA cells at station. Note: The rate quoted shall be including the cost of DC bus bar of 48 VDC/ Power wire suitable stand etc., connection of power supply to the equipments. All the wiring shall be done with the suitable gauge of power wires through suitable casing/caping as per the instructions of railway engineers. All the materials required for this item shall be supplied by the contractor. 1 No.
236 236 Installation, connection & commissioning of a set of surge protection system consisting of lightening current arrestors, 2 Nos. of class-B by connecting between phase & neutral & neutral & earth; class-C with inbuilt thermal isolating device on single phase supply. 1 Job
237 237 CABLE LAYING
238 238 Excavation of Trench, Depth 1.0 Mtr. & width 0.3 Mtr., in all soils including soft/hard rocky area and clearing of roots of trees, bushes, rocks etc., ballast and reconditioning etc., (including bailing out water and disposal of extra soil) including back filling with excavated earth and ramming of trenches after cable laying for the following depth and width as given below. The contractor has to conduct detailed site survey of the cable route as per Drg No. RITES/SIG/GEN/021-98. Prepare a plan to get approval of the owner's authorised representative, putting white lime powder marking before excavation of earth under supervision of owner's authorised representative. Wherever several cables of different categories have to be laid in the same path, all cables shall be separated with brick through out the length, instead of seperate trench in the concerned area. This also includes: 1 Km
239 239 Covering of laid cables in trenches by a layer of 550 mm thick loose soils before covering by split DWC pipe approxiamately
240 240 Disposal of soils, clearing of roots, bushes, etc in all types of soils
241 241 Laying of cable route markers along with the cable route as per the instruction of site incharge.
242 242 Excavation of cable trench of 1.0 m. depth & 300 mm. wide across the track width at level / track/Road crossing platform & refilling after laying DWC/RCC pipe (laying of DWC/RCC pipe shall be paid under separate item of schedule) as per cable route chart & technical specification as per Drg.NO.RITES/SIG/GEN/028-98. This include repairing and plastering of platform/pucca road after cable laying. 1 Mtr.
243 243 NOTE:- Power cable, signalling cable, Quad cable, PIJF, OFC etc. as mentioned above, where required, shall be laid in the same trench as signalling cable but in a separate pipe.
244 244 Cutting smoothening of inside surface of chase in concrete or hard rocks having size 80mm depth & 70mm width. This work includes laying & covering of cable laid in the chase with brick (225 x 100x 75 mm) i.e. 9 bricks per meter second class bricks placed & embedded longitudinally & plastered on the top of the bricks as per drg No. RITES/SIG/GEN/025-98. This item includes the cost of bricks, cement & sand etc. 1 Mtr.
245 245 Filling of cable duct by sieved silver/fine sand after laying of cable in relay rooms. Supply of sand shall be made by the contractor. 1 Cum.
246 246 Transportation & Fixing/ laying of DWC/RCC pipes for laying of cables (including under-neath the track, Road crossing or other platform cutting etc.) as per drg.No. RITES/SIG/GEN/028-98 & RITES/SIG/GEN/031-98. 1 Mtr.
247 247 Transportation & Fixing of Galvanised iron pipe 100 mm dia. on panel buildings. This includes supply of clamps, support, nuts, bolts etc. & concreting of ends with brick masonary work including supply of cement, sand an aggregate. 1 Mtr.
248 248 Transportation of cables in roll with or without wooden drums to work site and meggering before loading and after laying, and recording the values in cable insulation register along with representative. 1 Drums/Rolls
249 249 Laying of signalling/Telecom cable in the trench/GI/RCC/DWC pipe as per cable route plan (Note: before issuing of cable to the contractor, the cable will be meggered jointly by the contractor and RITES Engineer at site and meggering certificate will be submitted in the office of the Engineer In Charge. Where cable is laid in HDPE pipes, no protective bricks are required. The same procedure will be adopted after the cable in laid at site without which no payment will be made to the contractor. If the insulation resistance after laying of cable is less than the reading previous meggering report. The contractor will have to repair or replace the defective cable at his own cost for which no charges will be paid . 1 Km.
250 250 Termination of all cores of all types of Indoor/outdoor cables (Excluding termination in location boxes and terminations on items coming under item No.1 &3 of Schedule A (Supply )after its laying, on both ends and providing number ferrule on each core. This also includes fixing of ARA terminals/disconnecting type terminal block/ 8 way strip, meggering and preparation of test report for core to core and core to earth on prescribed proforma for each core of the cable separately. This also includes dressing and lacing of cables on both ends. Proforma for testing and material for lacing to be supplied by the contractor. 1 Core
251 251 Laying of 40/33 mm dia HDPE pipe as per approved cable route plan in the excavation trench at 1 mtr depth. 1 Km
252 252 Providing Heat Shrinkable joint for all type of S&T cable with contractor's all materials. 1 No.
253 253 All the materials required for the work are to be arranged by the contradtor himself at his own cost except Thermoshrinkable jointing kit which is already covered in Supply portion of the tender.After jointing the cable through test such as insulation test,Continuity cable losses etc. to be carried out jointly with the Railway Engineer. If any defect or any damage observed during jointing, the contractor should redo the joint free of cost.
254 254 POINT MACHINE
255 255 Installation, wiring, testing and commissioning of 110 V, DC point machine as per specifications and approved wiring diagrams. This includes: 1 No
256 256 Fixing of point machines on MS plate fixed on sleepers complete with fixing of anti theft covers, cable terminal box, ground connection.
257 257 Fixing of insulation for gauge tie plate and crossing plate for 52 / 60 Kg. points and crossings.
258 258 Fixing of insulation for switch extention pieces (D brackets) and leading & following stretcher bars.
259 259 Wiring from the cable termination box to the point machine as per specifications.
260 260 All smithy works.
261 261 Supply of MS plates, flat, angle, bolts, nuts, pins as required.This item also includess supply & fixing of GI pipe bend for the protection of cable from cable termination box to piont machine.
262 262 Testing the point machines from point of operation including testing with 5 mm test piece.
263 263 Installation and wiring of Rotary key transmitters/KLCR on teak wood board enclosed inside a suitable box with front transparent check cover with locking arrangement. This includes 3/4" thick teak wood boards, transparent sheet for box, locking arrangement. 2 nos.of locks for box and 1 No. lock for front transparent sheet. 1 No.
264 264 P-way works required before provision of point machines such as .squaring of switches, packing and leveling/alignment of track,easing or rails on either side of points to be interlocked,making proper spacing of sleepers etc 1 Job
265 265 Fabrication, supply and erection of name plate for point machine as per Drg. No. RITES/S&T/ROU/PMNP-01 and as per instruction of Site Engineer. This includes supply of MS Plate (Size: 350mm x 250mm, 3mm thick), MS Angle (Size: 25mm x 25mm, 3mm thick), Cement, Sand, Aggregate, Paint and all other material required for this work. All the smithy mechanical and electrical work/arrangement shall be done by the contractor at his own cost. Point Number shall be written in black on yellow background in 150mm height on both side of the plate. 1 No.
266 266 DC TRACK CIRCUIT
267 267 Fixing & wiring of track circuit equipment such as battery chargers, track feed resistance, `B' type choke, relays batteries etc. as per approved wiring diagram in location box. This includes :- \n(i)Supply, fabrication & fixing of duly varnish teakwood planks of 25 mm thick. \n(ii)Supply of fixing material. 1 No.
268 268 Installation, wiring, testing & commissioning of DC track circuits as per approved standard practice. This includes :
269 269 Installation of all types of lead wires, jumpers and rail head continuity bonds ,insulation joints using contractors own consumables & pin brazing machine
270 270 Fixing of track lead junction boxes as per drg. No. RITES/SIG/GEN/039-2007. This also includes painting of TLJB.
271 271 Charging of track Batteries, Energising the track circuit and testing with 0.5 ohms train shunt resistance.
272 272 On straight portion of track 1 No
273 273 On point and crossing portion of track 1 No
274 274 COLOUR LIGHT SIGNALS
275 275 Excavation of pit, casting & plastering of concrete foundation for C.L.Signal & ladder. as per drg.No.RITES/SIG/GEN/001 -98. This includes : Supply of cement, sand, stone chip & mixing in the ratio 1:3:6. 1 No.
276 276 Erection of 2 aspect colour light signals.This includes : 1 No.
277 277 Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.
278 278 Wiring & testing of signal unit as per the specifications and directives of engineer at site.
279 279 Erection of 3/4 aspect colour light signals.This includes : 1 No
280 280 Erection of surface base, signal post, signal unit, junction type route indicator, shunt signal on offset bracket,calling on signal, ladder with guard & platform. Fixing of signal number plate, P/C/G marker & blanking-off signals. It will also include protective screen, wherever required.Fixing of hoods & LED lamp units with current regulating transformer on 2 aspect signal. Termination of the tail cable in the signal unit.This incuded digging/pulling of cable already laid. This item includes the cost of all the fixing materials required to execute this activity.
281 281 Wiring & testing of signal unit as per the specifications and directives of engineer at site.
282 282 Testing & commissioning of 2 /3/4aspect colour light signals. 1 No
283 283 Excavation of pit, casting & plastering of concrete foundation for shunt signal. As per Drg. No.RITES/SIG/ GEN/002-98. This includes : Supply of foundation nuts & Bolts, cement, sand, stone chip & mixing in the ratio 1:3:6. 1 No
284 284 Erection & wiring of independent shunt signal. This includes : 1 No.
285 285 Erection of surface base, shunt signal post, shunt signal unit.
286 286 Fixing of hoods and LED lamps with regulating transformer.
287 287 Termination of the tail cable in the signal unit.
288 288 Wiring of shunt signal unit with wiring material.
289 289 Necessary arrangement of material to be used by bidder own arrangement.
290 290 Installation of shunting limits boards/Goods warning board/stop board as per standard practice at site. The necessary materials like cement, concrete and sand etc., for the installation of these boards shall be supplied by contractor. 1 No
291 291 APPARATUS CASE
292 292 Excavation of pit, casting of concrete foundations for full location box as per Drg.No.RITES/SIG/GEN /003-09 This includes : Supply of Foundation Bolts and nuts, cement, sand, stone chip & mixing in the ratio 1:3:6. 1 No.
293 293 Erection of full location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This includes - 1 No
294 294 (i). Necessary arrangement of material& fixing of hylum sheet on 25 x 25 x 3 mm angle iron frame , resin bonded 10 mm thick grade P3 in standard size for shelves, boardfor fixing ARA terminal, disconnecting type terminal blocks, fuse blocks etc.
295 295 (ii). Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.This also includes clamping of ables with contractors own material
296 296 (iii). Filling up pit inside the location box by sand and plastering on the top of the sand.
297 297 (iv). Fixing of terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. fuses, etc. as per approved wiring diagrams.
298 298 Excavation of pit, casting of concrete foundations for Half location box as per Drg.No.RITES/SIG/GEN/004-09. This includes : Supply of foundation nut bolts of required size, cement, sand, stone chip & mixing in the ratio 1:3:6. 1 No.
299 299 Erection of Half location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This also includes: 1 No
300 300 Supply & fixing of hylum sheet, on 25x25x3 mm angle iron frame, resin bonded 10 mm thick grade P3 in standard size for shelves, board for fixing ARA terminal disconnecting type terminal block, fuse block etc.
301 301 Termination of cables with number embossed ferrules, bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamp etc. This also includes clamping of cables with contractors own material
302 302 Filling up pit inside the location box by sand and plastering on the top of the sand.
303 303 Fixing of ARA/wago terminal terminals, 8 way strips, disconnecting type terminal blocks, fuse blocks, N.D. Fuses, etc. As per approved wiring diagram.
304 304 Installation, wiring, testing and commissioning of Electrical Lifting Barrier, complete with casting of cement concrete foundation as per manufacturer's drawing for pedestal and boom rest, post, wire run, operating winch/Panel, Rodding, cabling, power supply connection, wiring in loc. box or in rack etc. Wiring of Hooter, Flasher and road signals. Supply, provision, fixing and wiring of Electric key transmitter and establishment of interlocking as per approved diagram. 1 Set
305 305 PAINTING
306 306 Painting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface whereever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes inside & outside surfaces with Aluminium paint.
307 307 Full case 1 No
308 308 Half case 1 No
309 309 Painting of Main signal post with signal unit, surface base complete with route indicator, dependent shunt, calling On unit, ladder fittings as per Indian.Rlys. standard practice. 1 No
310 310 Painting of two coats of enamel paint black Asian and Aiuminium white as approved by Site engineer over one coat of primer on Shunt signal unit , base and post item218 1 No
311 311 Painting of two coats of enamel paint black Asian and red oxide as approved by Site engineer over one coat of primer on point machine and ground connection respectively 1 No
312 312 SM Panel
313 313 Wiring & installation and commissioning of magneto telephones between ASM office & other locations in the yard. Providing & wiring telephone sockets in all the location boxes. Necessary stand for keeping the magneto telephone shall also be provided, this includes all the materials except items covered in supply schedule. item221 1 No
314 314 Cement concrete work for miscellaneous items with supply of cement, sand, stone chips and mixing in the ratio 1:3:6. This item includes excavation, raming, curing and plastering with cement & sand mixture (stone chips size not exceeding 40mm). item222 1 Cu.Mtr
315 315 Providing brick massonary in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor's own IInd nd class bricks including excavation curing, grouting,bolting etc. Whereever required bricks sand and cement to be supplied by the contractor. item223 1 Cu.Mtr
316 316 Foundation & fixing all types of cranks & A type foundation item224 1 No.
317 317 Dismantalling of all existing indoor electrical and mechanical signalling gears at end cabin,station etc 1 LS/Stn
318 318 BLOCK INSTRUMENT
319 319 Installation, wiring, testing and commissioning of Block Instrument - Block proving by Axle Counter (BPAC) along with Universal Fail Safe Block Interface (UFSBI). This includes supply of all the materials (which are not covered in supply schedule) required for the job . 1 No.
320 320 TELECOMMUNICATION
321 321 Installation and commissioning of 25W radio at station building. This includes erection of power supply unit and antenna with support pipe. item229 1 Set
322 322 Fabrication of emergency socket box, assembly and erection of fabricated assembly at the location indicated in the route chart and as per direction of Engineer in charge. This includes cutting of rails to required size, supply and welding of GI Pipe and base plate, fixing of Emergency socket Box, transportion of matrial to site, digging of pit and erection of whole assembly at site. The work also includes the termination of 6 Quad/PDF derivation cable on the strip of 6 pin Emergency Socket inside emergency socket box. The fabrication of Emergency socket box shall be done as per extent practice of Railway. item230 1 Nos
323 323 Painting of emergency socket assembly and rail post by applying one coat of red oxide as base colour and then painting the assembly as per zebra painting in white and block colours. The width of each of the black and white colours shall be 100mm. All paints used shall be with ISI mark. item231 1 Nos
324 324 Manual horizontal auger boring/drilling of 100mm dia Horizontal Bore across the Railway Track/Across Road at LC gates by boring method at a depth of 1.65 mm from the ground level/ground level to be considered ignoring the bank height of the bank/load and insertion of GI pipes etc. as per the instructions engineer in charge at site as per drg. no. RAIL TEL/SR. OFC/2008/10. item232 1 Mtr.
325 325 Blowing of OFC through HDPE duct & protective work (elicited in above item) already provided. Where it is not feasible to blow OFC due to curves, road/track crossings, bridges or for any other reason, OFC shall be drawn/laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of item no. (6h) of this schedule. OFC and HDPE pipe shall be supplied by the railway. item233 1 KM
326 326 Splicing of laid OFC cable and making the splice joint in dust free environment with contractror's own equipment and labour. Straight joint enclosure (SJC) is covered under bill 1, remaining all required materials, tools and plants shall be arranged by the contrcator. Splicing shall be started from one end and each splicing shall be monitored after splicing and after closing the enclosure for all the fibres frm one central location by contractor's engineer with his own OTDR and optic talk set with Railway engineer, traced for the fibres from the taken signed jointly if any fibre splice shows high loss, lossy event, the same shall be redone before completion of splicing work. item234 1 No
327 327 Installation and wiring of SDH / STMs supplied with all accessories, DDF with miniature ‘U’ link type for 63 E1s, runway ladder etc in already installed 42-U Euro rack. This includes connecting all pig tails, optical patch cords etc. to the SDH equipment. This also includes connecting the SDH with all interface cards to the 48V Bus including supply of wires and connectors, termination of all E1s on DDF. This includes all the sundry material required for installation. item235 1 No
328 328 Installation of fiber distribution management system with contractor's own installation material, splicing and termination of 2x24 fiber OFC, routing dressing fibers as per instructions of Engineer incharge. item236 1 No
329 329 Installation, testing and commisioning of NMS including uploading of STM/PD MUX.All the required fixing hardware material will be arrenged by contractor free of cost. item237 1 No
330 330 Supply and installation of Optical Fiber termination box as per spec No. DPG/G/FIB-01/02 Mar 99 or DOT/G/FTB-01, Jan 93 or with latest amendment and splicing of all the fibers inside the termination box with provision of taking out OFC as required. This includes supply of all installation acccessories required to complete th installation as per spec No. G/OFJ-01/03 June 99 with latest amendment 10 mtr long patch cord as per spec. No. G/OJF-01/01 with connector as per code of practice for installation and commissioning of OFC. item238 1 No
331 331 Schedule- C Construction of S&T Building & Electrification
332 332 Construction of S&T Panel Buildingwith doors & windows having locking arrangement, foundation work, superstructure, slab etc. complete in all respect as per approved drawings of RITES, including supply of materials, painting etc.This also includes electrification in S&T panel building ,preparation of detail design as required for obtaining approval of RITES.Typical plans for S&T building and its electrification are provided in tender document.
333 333 Ground floor, Plinth area item242 1 Sqm