Construction Of 3 Material Recovery Cum Transfer Stations Under Chandigarh Smart City
Tender Value
17.84 Crore
Estimated cost
Bid Submission
11 Feb 2020
0 days left
EMD
27.85 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of 3 Material Recovery Cum Transfer Stations Under Chandigarh Smart City
BOQ
| Name of Work: Construction of 3 Material Recovery cum Trasnfer Station Under Chandigarh Smart City | |||||
|---|---|---|---|---|---|
| Sl.No. | Item Description | Item Code / Make | Quantity | Units | |
| 1 | 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. | BI01010001010000000000000515BI0100001113 | ||
| 2 | 1.02 | All kinds of soil (DSR 2.6.1) | BI01010001010000000000000515BI0100001114 | 3656.75 | Cum |
| 3 | 1.03 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. | BI01010001010000000000000515BI0100001115 | ||
| 4 | 1.04 | All kinds of soil (DSR 2.26.1) | BI01010001010000000000000515BI0100001116 | 880.652 | Cum |
| 5 | 1.05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR 2.25) | BI01010001010000000000000515BI0100001117 | 2898.26 | Cum |
| 6 | 1.06 | Carriage of earth by mechanical transport including loading, unloading and stacking upto 12 km in all respect and direction by Engineer-in-Charge. (DSR 1.1.2) | BI01010001010000000000000515BI0100001118 | 505.665 | Cu.m |
| 7 | 1.07 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | BI01010001010000000000000515BI0100001119 | ||
| 8 | 1.08 | 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) (DSR 4.1.10) | BI01010001010000000000000515BI0100001120 | 72.953 | Cu.m |
| 9 | 1.09 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) (DSR 4.1.5) | BI01010001010000000000000515BI0100001121 | 28.555 | Cu.m |
| 10 | 1.1 | 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (DSR 4.1.3) | BI01010001010000000000000515BI0100001122 | 0.304 | Cu.m |
| 11 | 1.11 | Providing and laying in position ready mixed M-20 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.\n(Note :- Cement content considered in this item is @ 300 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). | BI01010001010000000000000515BI0100001123 | ||
| 12 | 1.12 | All works upto plinth level (NSI) | BI01010001010000000000000515BI0100001124 | 383.282 | Cum |
| 13 | 1.13 | All works above plinth level upto floor five level (NSI) | BI01010001010000000000000515BI0100001125 | 83.112 | Cum |
| 14 | 1.14 | Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). \n(Note:- Cement content considered in this item is @ 300 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (NSI) | BI01010001010000000000000515BI0100001126 | 336 | Cum |
| 15 | 1.15 | Centering and shuttering including strutting, propping etc. and removal of form for : | BI01010001010000000000000515BI0100001127 | ||
| 16 | 1.16 | Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) | BI01010001010000000000000515BI0100001128 | 789.384 | Sq.m |
| 17 | 1.17 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) | BI01010001010000000000000515BI0100001129 | 708 | Sq.m |
| 18 | 1.18 | Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) | BI01010001010000000000000515BI0100001130 | 739.2 | Sq.m |
| 19 | 1.19 | Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) | BI01010001010000000000000515BI0100001131 | 487.486 | Sq.m |
| 20 | 1.2 | Edges of slabs and breaks in floors and walls | BI01010001010000000000000515BI0100001132 | ||
| 21 | 1.21 | Under 20 cm wide (DSR 5.9.16.1) | BI01010001010000000000000515BI0100001133 | 380.79 | mtr |
| 22 | 1.22 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.\n(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). | BI01010001010000000000000515BI0100001134 | ||
| 23 | 1.23 | All works upto plinth level (DSR 5.33.1) | BI01010001010000000000000515BI0100001135 | 87 | Cum |
| 24 | 1.24 | Extra for providing richer mixes at all floor levels.\nNote:- Excess/less cement over the specified cement content used is payable /recoverable separately. | BI01010001010000000000000515BI0100001136 | ||
| 25 | 1.25 | Providing M-30 grade concrete instead of M-25 grade RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) (DSR 5.34.1) | BI01010001010000000000000515BI0100001137 | 87 | Cum |
| 26 | 1.26 | Excess/ less cement used as per design mix is payable/recoverable (NSI) | BI01010001010000000000000515BI0100001138 | 2134.28 | Quintal |
| 27 | 1.27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: | BI01010001010000000000000515BI0100001139 | ||
| 28 | 1.28 | Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) | BI01010001010000000000000515BI0100001140 | 346.988 | Cu.m |
| 29 | 1.29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : | BI01010001010000000000000515BI0100001141 | ||
| 30 | 1.3 | Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) | BI01010001010000000000000515BI0100001142 | 230.251 | Cum |
| 31 | 1.31 | Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) | BI01010001010000000000000515BI0100001143 | 204.505 | Cum |
| 32 | 1.32 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. | BI01010001010000000000000515BI0100001144 | ||
| 33 | 1.33 | Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) | BI01010001010000000000000515BI0100001145 | 37.377 | Sq.m |
| 34 | 1.34 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27) | BI01010001010000000000000515BI0100001146 | 3580.96 | Cu.m |
| 35 | 1.35 | Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. (DSR 16.80) | BI01010001010000000000000515BI0100001147 | 1442.03 | Cum |
| 36 | 1.36 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. | BI01010001010000000000000515BI0100001148 | ||
| 37 | 1.37 | With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 (DSR 16.78.1) | BI01010001010000000000000515BI0100001149 | 212.1 | Cum |
| 38 | 1.38 | With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) | BI01010001010000000000000515BI0100001150 | 1879.55 | Cu.m |
| 39 | 1.39 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.79) | BI01010001010000000000000515BI0100001151 | 1879.55 | Cu.m |
| 40 | 1.4 | Providing and laying design mix cement concrete of M-40 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). | BI01010001010000000000000515BI0100001152 | ||
| 41 | 1.41 | Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer \nNote:- Cement content considered in M-40 is @ 360 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. (NSI) | BI01010001010000000000000515BI0100001153 | 1252.02 | Cu.m |
| 42 | 1.42 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).\nNote:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately. | BI01010001010000000000000515BI0100001154 | ||
| 43 | 1.43 | Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer (DSR 16.43.2) | BI01010001010000000000000515BI0100001155 | 1296.04 | Cu.m |
| 44 | 1.44 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. | BI01010001010000000000000515BI0100001156 | ||
| 45 | 1.45 | Using grade ‘A’ sealing compound. (DSR 16.46.1) | BI01010001010000000000000515BI0100001157 | 600 | per cm depth per cm width per metre\nlength |
| 46 | 1.46 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. | BI01010001010000000000000515BI0100001158 | ||
| 47 | 1.47 | Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) | BI01010001010000000000000515BI0100001159 | 39831.6 | KG |
| 48 | 1.48 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. | BI01010001010000000000000515BI0100001160 | ||
| 49 | 1.49 | Mild steel and Medium Tensile steel bars (DSR 5.22A.1) | BI01010001010000000000000515BI0100001161 | 1320 | KG |
| 50 | 1.5 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.2) | BI01010001010000000000000515BI0100001162 | 406216 | KG |
| 51 | 1.51 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineering- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (DSR 12.50) | BI01010001010000000000000515BI0100001163 | 12984.7 | Sq.m |
| 52 | 1.52 | Supply and installation of 2mm thick clear embossed Polycarbonate Sheet (Polycarbonate profile to match with standing seam profile with side laps to be clamped with bare precoated sheets of 0.5mm,(tct) which can be further seamed with metal roof sheets. Product required is clear embossed with both sides UV stabilizer, having at leasts 60 - 80% transparency, conforming to the relevant IS Code including cutting to shape and size required including necessary sealants. Including all materials, tools & tackles, labours etc. in complete all respect as per the direction of Engineer- in-Charge. (NSI) | BI01010001010000000000000515BI0100001164 | 241.08 | Sq.m |
| 53 | 1.53 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete | BI01010001010000000000000515BI0100001165 | ||
| 54 | 1.54 | Gutter (600 mm over all girth) (DSR 12.51.6) | BI01010001010000000000000515BI0100001166 | 633.6 | Metre |
| 55 | 1.55 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.1) | BI01010001010000000000000515BI0100001167 | 1354.36 | Kg |
| 56 | 1.56 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. | BI01010001010000000000000515BI0100001168 | ||
| 57 | 1.57 | 160 mm diameter (NSI) | BI01010001010000000000000515BI0100001169 | 913.77 | Metre |
| 58 | 1.58 | Providing and fixing on wall face unplasticised - PVC moulded 160 mm dis Shoe (Plain) for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (NSI) | BI01010001010000000000000515BI0100001170 | 99 | Each |
| 59 | 1.59 | Supplying, installation, testing & commissioning of belt conveyor system with suitable swivel/ rotatable chute to unload garbage form belt conveyer to tipcart such that there is no interference with tipcart while tipping with geared motor of suitable capacity.\nDimensions – i) Length 30.00mtr. ii) Width 1.50mtr. iii) Height above finish floor level of platform Minimum 1.20mrt or suitable as per machine requirement. The belt should be 3 ply belt, 125X75 mm channel X head pulley rubberized, tail pulley carrying idlers 90 mm dia return rollers impact idlers screw tensioning arrangement complete with two no. coats of paint including modular type Electrical Panel of suitable capacity to control the operation of Belt Conveyor system as per relevant BIS Codes. (NSI) | BI01010001010000000000000515BI0100001171 | 6 | Each |
| 60 | 1.6 | Construction of M30 grade RCC precast/ Prestressed Boundary wall all complete as per specification. (NSI) | BI01010001010000000000000515BI0100001172 | 3138.71 | Sq.m |
| 61 | 1.61 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).\n(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR 16.75) | BI01010001010000000000000515BI0100001173 | 565.6 | cum |
| 62 | 1.62 | Supply, Installation, Testing & Commissioning of 10 ton capacity electrical weighing bridge with software for automatic transfer of data for day to day calculation of weight all complete as per technical Specifications. (NSI) | BI01010001010000000000000515BI0100001174 | 9 | Each |
| 63 | 1.63 | Supplying, installation, testing & commissioning of RFID enabled, antic rash beam sensor automatic hydraulic boom barrier with UHF Tag all complete as per specification. (200 nos UHF Tag for each station) (NSI) | BI01010001010000000000000515BI0100001175 | 3 | Job |
| 64 | 1.64 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (DSR 2.25(a)) | BI01010001010000000000000515BI0100001176 | 40609.3 | Cu.m |
| 65 | 1.65 | Supplying, erecting & commissioning of automatic motorised steel gate all complete as per specification. (NSI) | BI01010001010000000000000515BI0100001177 | 6 | Each |
| 66 | 1.66 | Supplying, fixing, testing & commissioning of automatic truck tyre washing system including Wash Platform, Side Screens, Wash Pump, Recycle Water tank, Entry Vehicle Detection sensor etc. all complete as per specification. (NSI) | BI01010001010000000000000515BI0100001178 | 1 | Job |
| 67 | 1.67 | Supplying, fixing, testing & commissioning of Cold High Pressure truck tyre washing system with Foam sprayer etc. all complete as per specification. (NSI) | BI01010001010000000000000515BI0100001179 | 2 | Job |
| 68 | 1.68 | Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in foundation, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (NSI) | BI01010001010000000000000515BI0100001180 | 2.222 | Cu.m |
| 69 | 1.69 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (DSR 6.15) | BI01010001010000000000000515BI0100001181 | 37.377 | Sq.m |
| 70 | 1.7 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand (DSR 13.1.1) | BI01010001010000000000000515BI0100001182 | 1548.2 | Sqm |
| 71 | 1.71 | 20 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) (DSR 13.3.2) | BI01010001010000000000000515BI0100001183 | 1713.78 | Sqm |
| 72 | 1.72 | 6 mm cement plaster of mix : | BI01010001010000000000000515BI0100001184 | ||
| 73 | 1.73 | 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) | BI01010001010000000000000515BI0100001185 | 378.122 | Sq.m |
| 74 | 1.74 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80) | BI01010001010000000000000515BI0100001186 | 1926.32 | Sqm |
| 75 | 1.75 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade | BI01010001010000000000000515BI0100001187 | ||
| 76 | 1.76 | New work (two or more coats) over and including water thinnable priming coat with cement primer (DSR 13.41.1) | BI01010001010000000000000515BI0100001188 | 1926.32 | Sqm |
| 77 | 1.77 | Finishing walls with water proofing cement paint of required shade : | BI01010001010000000000000515BI0100001189 | ||
| 78 | 1.78 | New work (Two or more coats applied @ 3.84 kg/10 sqm) (DSR 13.44.1) | BI01010001010000000000000515BI0100001190 | 1713.78 | Sqm |
| 79 | 1.79 | Finishing walls with Acrylic Smooth exterior paint of required shade : | BI01010001010000000000000515BI0100001191 | ||
| 80 | 1.8 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (DSR 13.46.1) | BI01010001010000000000000515BI0100001192 | 1713.78 | Sqm |
| 81 | 1.81 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31) | BI01010001010000000000000515BI0100001193 | 309.324 | Sqm |
| 82 | 1.82 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR 11.37) | BI01010001010000000000000515BI0100001194 | 76.517 | Sqm |
| 83 | 1.83 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. | BI01010001010000000000000515BI0100001195 | ||
| 84 | 1.84 | Size of Tile 800x800 mm (DSR 11.41.3) | BI01010001010000000000000515BI0100001196 | 218.412 | Sqm |
| 85 | 1.85 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. | BI01010001010000000000000515BI0100001197 | ||
| 86 | 1.86 | 80x1.25 mm M.S. laths with 1.25 mm thick top cover (DSR 10.6.1) | BI01010001010000000000000515BI0100001198 | 14.4 | Sqm |
| 87 | 1.87 | Door & Window | BI01010001010000000000000515BI0100001199 | ||
| 88 | 1.88 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :\nPowder coated aluminium (minimum\nthickness of powder coating 50 micron) | BI01010001010000000000000515BI0100001200 | ||
| 89 | 1.89 | For fixed portion | BI01010001010000000000000515BI0100001201 | ||
| 90 | 1.9 | Powder coated aluminium (minimum thickness of powder coating 50 micron)\nDouble Rebate (DSR 21.1.1.2) | BI01010001010000000000000515BI0100001202 | 425.114 | Kg |
| 91 | 1.91 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. | BI01010001010000000000000515BI0100001203 | ||
| 92 | 1.92 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) | BI01010001010000000000000515BI0100001204 | 31.5 | sqm |
| 93 | 1.93 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : | BI01010001010000000000000515BI0100001205 | ||
| 94 | 1.94 | 35 mm thick shutters | BI01010001010000000000000515BI0100001206 | ||
| 95 | 1.95 | With ISI marked stainless steel butt hinges of\nrequired size | BI01010001010000000000000515BI0100001207 | ||
| 96 | 1.96 | Kiln seasoned selected class of sheesham wood (DSR 9.27.1.2.3) | BI01010001010000000000000515BI0100001208 | 31.5 | sqm |
| 97 | 1.97 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 0x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (DSR 9.53) | BI01010001010000000000000515BI0100001209 | 264 | Each |
| 98 | 1.98 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). | BI01010001010000000000000515BI0100001210 | ||
| 99 | 1.99 | Kiln seasoned and chemically treated hollock wood (DSR 9.1.3) | BI01010001010000000000000515BI0100001211 | 0.277 | cum |
| 100 | 2 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. | BI01010001010000000000000515BI0100001212 | ||
| 101 | 2.01 | Kiln seasoned selected planks of sheesham wood | BI01010001010000000000000515BI0100001213 | ||
| 102 | 2.02 | 35 mm thick (DSR 9.9.3.1) | BI01010001010000000000000515BI0100001214 | 76.68 | sqm |
| 103 | 2.03 | Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR 9.14) | BI01010001010000000000000515BI0100001215 | 76.68 | Sqm |
| 104 | 2.04 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. (DSR 9.121) | BI01010001010000000000000515BI0100001216 | 105.45 | metre |
| 105 | 2.05 | 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. (DSR 9.122.1) | BI01010001010000000000000515BI0100001217 | 36.225 | Sqm |
| 106 | 2.06 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : | BI01010001010000000000000515BI0100001218 | ||
| 107 | 2.07 | 150x10 mm (DSR 9.97.4) | BI01010001010000000000000515BI0100001219 | 66 | Each |
| 108 | 2.08 | 200x10 mm (DSR 9.97.3) | BI01010001010000000000000515BI0100001220 | 78 | Each |
| 109 | 2.09 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : | BI01010001010000000000000515BI0100001221 | ||
| 110 | 2.1 | 125 mm (DSR 9.100.1) | BI01010001010000000000000515BI0100001222 | 48 | Each |
| 111 | 2.11 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : | BI01010001010000000000000515BI0100001223 | ||
| 112 | 2.12 | 300x16 mm (DSR 9.96.1) | BI01010001010000000000000515BI0100001224 | 24 | each |
| 113 | 2.13 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. | BI01010001010000000000000515BI0100001225 | ||
| 114 | 2.14 | Single rubber stopper (DSR 9.101.1) | BI01010001010000000000000515BI0100001226 | 18 | Each |
| 115 | 2.15 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR 9.84) | BI01010001010000000000000515BI0100001227 | 18 | Each |
| 116 | 2.16 | Water Supply Plumbing | BI01010001010000000000000515BI0100001228 | ||
| 117 | 2.17 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : | BI01010001010000000000000515BI0100001229 | ||
| 118 | 2.18 | W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) | BI01010001010000000000000515BI0100001230 | 15 | Each |
| 119 | 2.19 | Providing and fixing 8 mm dia C.P. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (DSR 17.16A) | BI01010001010000000000000515BI0100001231 | 15 | Each |
| 120 | 2.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | BI01010001010000000000000515BI0100001232 | ||
| 121 | 2.21 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) | BI01010001010000000000000515BI0100001233 | 15 | Each |
| 122 | 2.22 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR 17.70) | BI01010001010000000000000515BI0100001234 | 24 | each |
| 123 | 2.23 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing | BI01010001010000000000000515BI0100001235 | ||
| 124 | 2.24 | Rectangular shape 453x357 mm (DSR 17.32.2) | BI01010001010000000000000515BI0100001236 | 15 | Each |
| 125 | 2.25 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | BI01010001010000000000000515BI0100001237 | ||
| 126 | 2.26 | 15 mm nominal bore (DSR 18.52.1) | BI01010001010000000000000515BI0100001238 | 30 | each |
| 127 | 2.27 | Providing and fixing C.P. brass angular stop cock\n15mm nominal bore (NSI) | BI01010001010000000000000515BI0100001239 | 15 | each |
| 128 | 2.28 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (DSR 18.15.1) | BI01010001010000000000000515BI0100001240 | 15 | each |
| 129 | 2.29 | Providing and fixing partitions for different type of urinals.\nVitreous white Chinaware Partition\nLarge partitions size 835mm x 355mm (NSI) | BI01010001010000000000000515BI0100001241 | 12 | Each |
| 130 | 2.3 | Providing and fixing in position best Indian make soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the walls etc.\nC.P. brass soap dish Small (NSI) | BI01010001010000000000000515BI0100001242 | 12 | each |
| 131 | 2.31 | Providing and fixing in position towel rails / ring fixed in with rawl plugs embedded in walls with brass screws, complete in all respects including cutting and making good the walls etc.\nC.P brass towel ring (NSI) | BI01010001010000000000000515BI0100001243 | 12 | each |
| 132 | 2.32 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : | BI01010001010000000000000515BI0100001244 | ||
| 133 | 2.33 | Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern (DSR 17.4.3) | BI01010001010000000000000515BI0100001245 | 9 | Each |
| 134 | 2.34 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : | BI01010001010000000000000515BI0100001246 | ||
| 135 | 2.35 | 15 mm dia nominal bore (DSR 18.11.1) | BI01010001010000000000000515BI0100001247 | 15 | metre |
| 136 | 2.36 | 20 mm dia nominal bore (DSR 18.11.2) | BI01010001010000000000000515BI0100001248 | 150 | metre |
| 137 | 2.37 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. | BI01010001010000000000000515BI0100001249 | ||
| 138 | 2.38 | 25 mm dia nominal bore (DSR 18.10.3) | BI01010001010000000000000515BI0100001250 | 45 | metre |
| 139 | 2.39 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. | BI01010001010000000000000515BI0100001251 | ||
| 140 | 2.4 | 50 mm dia nominal bore (DSR 18.12.6) | BI01010001010000000000000515BI0100001252 | 900 | metre |
| 141 | 2.41 | 25 mm dia nominal bore (DSR 18.12.3) | BI01010001010000000000000515BI0100001253 | 750 | metre |
| 142 | 2.42 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : | BI01010001010000000000000515BI0100001254 | ||
| 143 | 2.43 | 50 to 80 mm nominal bore (DSR 18.13.2) | BI01010001010000000000000515BI0100001255 | 6 | each |
| 144 | 2.44 | Providing, installation, testing & commissioning of Centrifugal pump self priming all complete as per RFP. (NSI) | BI01010001010000000000000515BI0100001256 | 3 | Each |
| 145 | 2.45 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : | BI01010001010000000000000515BI0100001257 | ||
| 146 | 2.46 | 15 mm nominal bore (DSR 18.46.1) | BI01010001010000000000000515BI0100001258 | 6 | each |
| 147 | 2.47 | 20 mm nominal bore (DSR 18.46.2) | BI01010001010000000000000515BI0100001259 | 6 | each |
| 148 | 2.48 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary oles for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR 18.48) | BI01010001010000000000000515BI0100001260 | 12000 | per litre |
| 149 | 2.49 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : | BI01010001010000000000000515BI0100001261 | ||
| 150 | 2.5 | 50 mm nominal bore (DSR 18.17.4) | BI01010001010000000000000515BI0100001262 | 6 | each |
| 151 | 2.51 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : | BI01010001010000000000000515BI0100001263 | ||
| 152 | 2.52 | 50 mm nominal bore | BI01010001010000000000000515BI0100001264 | ||
| 153 | 2.53 | Horizontal (DSR 18.19.4.1) | BI01010001010000000000000515BI0100001265 | 6 | each |
| 154 | 2.54 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks (DSR 18.76.1) | BI01010001010000000000000515BI0100001266 | 6 | each |
| 155 | 2.55 | Sanitary Installation Plumbing | BI01010001010000000000000515BI0100001267 | ||
| 156 | 2.56 | Providing and fixing soil, waste and vent pipes : | BI01010001010000000000000515BI0100001268 | ||
| 157 | 2.57 | 100 mm dia | BI01010001010000000000000515BI0100001269 | ||
| 158 | 2.58 | Sand cast iron S&S pipe as per IS: 1729 (DSR 17.35.1.1) | BI01010001010000000000000515BI0100001270 | 270 | metre |
| 159 | 2.59 | 75 mm dia | BI01010001010000000000000515BI0100001271 | ||
| 160 | 2.6 | Sand cast iron S&S pipe as per IS: 1729 (DSR 17.35.2.1) | BI01010001010000000000000515BI0100001272 | 150 | metre |
| 161 | 2.61 | Providing and fixing plain bend of required degree. | BI01010001010000000000000515BI0100001273 | ||
| 162 | 2.62 | 100 mm dia | BI01010001010000000000000515BI0100001274 | ||
| 163 | 2.63 | Sand cast iron S&S as per IS - 1729 (DSR 17.39.1.1) | BI01010001010000000000000515BI0100001275 | 15 | Each |
| 164 | 2.64 | 75 mm dia | BI01010001010000000000000515BI0100001276 | ||
| 165 | 2.65 | Sand cast iron S&S as per IS - 1729 (DSR 17.39.2.1) | BI01010001010000000000000515BI0100001277 | 15 | Each |
| 166 | 2.66 | Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter : | BI01010001010000000000000515BI0100001278 | ||
| 167 | 2.67 | 100 mm (DSR 17.58.1) | BI01010001010000000000000515BI0100001279 | 18 | Each |
| 168 | 2.68 | 75 mm (DSR 17.58.2) | BI01010001010000000000000515BI0100001280 | 18 | Each |
| 169 | 2.69 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : | BI01010001010000000000000515BI0100001281 | ||
| 170 | 2.7 | 100 mm inlet and 75 mm outlet | BI01010001010000000000000515BI0100001282 | ||
| 171 | 2.71 | Sand cast iron S&S as per IS - 3989 (DSR 17.60.2.1) | BI01010001010000000000000515BI0100001283 | 21 | Each |
| 172 | 2.72 | Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : | BI01010001010000000000000515BI0100001284 | ||
| 173 | 2.73 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (DSR 18.36.1) | BI01010001010000000000000515BI0100001285 | 9 | Each |
| 174 | 2.74 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : | BI01010001010000000000000515BI0100001286 | ||
| 175 | 2.75 | 150 mm diameter (DSR 19.1.1) | BI01010001010000000000000515BI0100001287 | 300 | metre |
| 176 | 2.76 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : | BI01010001010000000000000515BI0100001288 | ||
| 177 | 2.77 | 150 mm diameter S.W. pipe (DSR 19.2.1) | BI01010001010000000000000515BI0100001289 | 300 | metre |
| 178 | 2.78 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : | BI01010001010000000000000515BI0100001290 | ||
| 179 | 2.79 | For pipes 100 to 250 mm diameter (DSR 19.21.1) | BI01010001010000000000000515BI0100001291 | 3 | Each |
| 180 | 2.8 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : | BI01010001010000000000000515BI0100001292 | ||
| 181 | 2.81 | 300 mm dia. R.C.C. pipe (DSR 19.6.4) | BI01010001010000000000000515BI0100001293 | 900 | metre |
| 182 | 2.82 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : | BI01010001010000000000000515BI0100001294 | ||
| 183 | 2.83 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.27.1) | BI01010001010000000000000515BI0100001295 | 21 | Each |
| 184 | 2.84 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : | BI01010001010000000000000515BI0100001296 | ||
| 185 | 2.85 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : | BI01010001010000000000000515BI0100001297 | ||
| 186 | 2.86 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : | BI01010001010000000000000515BI0100001298 | ||
| 187 | 2.87 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.7.1.1) | BI01010001010000000000000515BI0100001299 | 21 | Each |
| 188 | 2.88 | Extra for depth for manholes : | BI01010001010000000000000515BI0100001300 | ||
| 189 | 2.89 | Size 90x80 cm | BI01010001010000000000000515BI0100001301 | ||
| 190 | 2.9 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.8.1.1) | BI01010001010000000000000515BI0100001302 | 21 | metre |
| 191 | 2.91 | Supply, Installation, testing and commissioning of 36 W LED StreetLight to installed with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. The luminarie should have (NSI) | BI01010001010000000000000515BI0100001303 | 84 | Each |
| 192 | 2.92 | Main Housing, frame : Powder coated, pressure die-cast Aluminum housing. | BI01010001010000000000000515BI0100001304 | ||
| 193 | 2.93 | Front Cover: Clear toughened glass with synthetic rubber gasket. | BI01010001010000000000000515BI0100001305 | ||
| 194 | 2.94 | LED: LM80 certified high power LED | BI01010001010000000000000515BI0100001306 | ||
| 195 | 2.95 | LED make Osram/Cree/Nichia | BI01010001010000000000000515BI0100001307 | ||
| 196 | 2.96 | Lens: Suitable secondary lens for better light distribution | BI01010001010000000000000515BI0100001308 | ||
| 197 | 2.97 | Gear: Integral, Electronic, constant current driver. | BI01010001010000000000000515BI0100001309 | ||
| 198 | 2.98 | Internal Wiring: Teflon insulated, Cu. Conductor. | BI01010001010000000000000515BI0100001310 | ||
| 199 | 2.99 | Hardware: SS & Ms zinc plated & passivated. | BI01010001010000000000000515BI0100001311 | ||
| 200 | 3 | Ingress protection: IP66 | BI01010001010000000000000515BI0100001312 | ||
| 201 | 3.01 | Impact resistance: IK07 | BI01010001010000000000000515BI0100001313 | ||
| 202 | 3.02 | Lumen maintenance: 50,000 Hrs @ L70 | BI01010001010000000000000515BI0100001314 | ||
| 203 | 3.03 | Operating temperature: -10°C to 50°C | BI01010001010000000000000515BI0100001315 | ||
| 204 | 3.04 | Rated voltage & frequency: 240V, 50Hz AC | BI01010001010000000000000515BI0100001316 | ||
| 205 | 3.05 | Wattage 36W±10% | BI01010001010000000000000515BI0100001317 | ||
| 206 | 3.06 | Current <0.17A | BI01010001010000000000000515BI0100001318 | ||
| 207 | 3.07 | Pf > 0.95 | BI01010001010000000000000515BI0100001319 | ||
| 208 | 3.08 | THD < 10% | BI01010001010000000000000515BI0100001320 | ||
| 209 | 3.09 | Efficacy > 100 lm/W | BI01010001010000000000000515BI0100001321 | ||
| 210 | 3.1 | Lumen=3600 | BI01010001010000000000000515BI0100001322 | ||
| 211 | 3.11 | CCT 5700- 6500K | BI01010001010000000000000515BI0100001323 | ||
| 212 | 3.12 | CRI > 70 | BI01010001010000000000000515BI0100001324 | ||
| 213 | 3.13 | Supply, Installation, testing and commissioning of 20W LED Batten Light to installed with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. The luminarie should have (NSI) | BI01010001010000000000000515BI0100001325 | 54 | Each |
| 214 | 3.14 | Main Housing, frame : Powder coated, Al. extrusion. | BI01010001010000000000000515BI0100001326 | ||
| 215 | 3.15 | Front Cover: Diffused PS/PMMA. | BI01010001010000000000000515BI0100001327 | ||
| 216 | 3.16 | LED: LM80 certified Osram/Cree/Nichia make | BI01010001010000000000000515BI0100001328 | ||
| 217 | 3.17 | Gear: Electronic constant current driver. | BI01010001010000000000000515BI0100001329 | ||
| 218 | 3.18 | Internal Wiring: Teflon insulated, Cu. Conductor. | BI01010001010000000000000515BI0100001330 | ||
| 219 | 3.19 | Hardware: Ms zinc plated & passivated. | BI01010001010000000000000515BI0100001331 | ||
| 220 | 3.2 | Ingress protection: IP20 | BI01010001010000000000000515BI0100001332 | ||
| 221 | 3.21 | Lumen maintenance: 50,000 Hrs @ L70 | BI01010001010000000000000515BI0100001333 | ||
| 222 | 3.22 | Operating Voltage range: 140V - 270V AC | BI01010001010000000000000515BI0100001334 | ||
| 223 | 3.23 | Operating temperature: -10°C to 55°C | BI01010001010000000000000515BI0100001335 | ||
| 224 | 3.24 | Rated voltage & frequency: 240V, 50Hz AC | BI01010001010000000000000515BI0100001336 | ||
| 225 | 3.25 | Rated voltage & frequency: 240V, 50Hz AC | BI01010001010000000000000515BI0100001337 | ||
| 226 | 3.26 | Wattage 20W±10% | BI01010001010000000000000515BI0100001338 | ||
| 227 | 3.27 | Current <0.09A | BI01010001010000000000000515BI0100001339 | ||
| 228 | 3.28 | Pf > 0.95 | BI01010001010000000000000515BI0100001340 | ||
| 229 | 3.29 | Ithd < 10% | BI01010001010000000000000515BI0100001341 | ||
| 230 | 3.3 | Efficacy > 100 lm/W | BI01010001010000000000000515BI0100001342 | ||
| 231 | 3.31 | Lumen= 2000 Lm | BI01010001010000000000000515BI0100001343 | ||
| 232 | 3.32 | CCT 5700K- 6500 K | BI01010001010000000000000515BI0100001344 | ||
| 233 | 3.33 | CRI > 80 | BI01010001010000000000000515BI0100001345 | ||
| 234 | 3.34 | Supply, Installation, testing and commissioning of 120 W LED High bay light to installed GI Bracket with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. (NSI) | BI01010001010000000000000515BI0100001346 | 108 | Each |
| 235 | 3.35 | System Wattage 120W±10% | BI01010001010000000000000515BI0100001347 | ||
| 236 | 3.36 | Lamp Type LM80 certified | BI01010001010000000000000515BI0100001348 | ||
| 237 | 3.37 | Optic Suitable lens cluster for optimum light distribution | BI01010001010000000000000515BI0100001349 | ||
| 238 | 3.38 | System Lumen efficacy 120 lm/W (min.) | BI01010001010000000000000515BI0100001350 | ||
| 239 | 3.39 | Lumen= 17400 Lm | BI01010001010000000000000515BI0100001351 | ||
| 240 | 3.4 | Internal Wiring: Teflon insulated, Cu. Conductor. | BI01010001010000000000000515BI0100001352 | ||
| 241 | 3.41 | Colour temperature 5700K | BI01010001010000000000000515BI0100001353 | ||
| 242 | 3.42 | CRI >70 | BI01010001010000000000000515BI0100001354 | ||
| 243 | 3.43 | THD<10% | BI01010001010000000000000515BI0100001355 | ||
| 244 | 3.44 | PF>0.95 | BI01010001010000000000000515BI0100001356 | ||
| 245 | 3.45 | Surge protection 5 KV Internal + 10 KV SPD | BI01010001010000000000000515BI0100001357 | ||
| 246 | 3.46 | Rated Voltage & frequency 240V, 50Hz | BI01010001010000000000000515BI0100001358 | ||
| 247 | 3.47 | Housing Al. PDC Housing | BI01010001010000000000000515BI0100001359 | ||
| 248 | 3.48 | Front cover Toughened glass | BI01010001010000000000000515BI0100001360 | ||
| 249 | 3.49 | Lumen maintenance 50,000 Hrs @ L70 | BI01010001010000000000000515BI0100001361 | ||
| 250 | 3.5 | Operating temperature -10°C to +50°C | BI01010001010000000000000515BI0100001362 | ||
| 251 | 3.51 | Ingress Protection IP65 | BI01010001010000000000000515BI0100001363 | ||
| 252 | 3.52 | Impact Resistance IK05 | BI01010001010000000000000515BI0100001364 | ||
| 253 | 3.53 | Supply,installation, testing & commissioning of 1200mm sweep celing fan BEE 5 Star rated,with copper widing complete with Aluminium blades, plastic canopies 2 nos. double ball bearing, MS hanging rod (as per site requirement) condenser, reels, clamps, etc. the body of fan and blades includes the cost of making necessary connections from adjacent light points with 1.5 sqmm single core copper conductor cable The job includes the cost of carriage, all labour and petty material required to complete the job to the entire satisfaction of Engineer in-charge. (NSI) | BI01010001010000000000000515BI0100001365 | 27 | Each |
| 254 | 3.54 | Supply & Erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operatio, epoxy powder coating along with metallic louver to be installed in existing opening including cost of making holes to suit the size of above fan making good damage, carriage charges connection, testing, commissioning, etc. as required to complete the job to the entire satisfaction of EIC | BI01010001010000000000000515BI0100001366 | ||
| 255 | 3.55 | Size 12 inches (300 mm) sweep, single phase, 900 RPM Heavy duty Exhaust fan (NSI) | BI01010001010000000000000515BI0100001367 | 9 | Each |
| 256 | 3.56 | Size 24 inches (600 mm) sweep, three phase, 900 RPM Heavy duty Exhaust fan (NSI) | BI01010001010000000000000515BI0100001368 | 30 | Each |
| 257 | 3.57 | MAIN LT PANEL - 1 no per location | BI01010001010000000000000515BI0100001369 | ||
| 258 | 3.58 | Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN Copper bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The LT panel should have provision of following switchgear and accessories:- \n(Note:- (Note: All MCCBs shall be with ROM, Spreader terminals) | BI01010001010000000000000515BI0100001370 | ||
| 259 | 3.59 | INCOMER | BI01010001010000000000000515BI0100001371 | ||
| 260 | 3.6 | 200 Amps. 36KA, four Pole, thermal megnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1 No. | BI01010001010000000000000515BI0100001372 | ||
| 261 | 3.61 | 200 Amps. 36KA, four Pole, thermal megnetic release , MCCB changeover switch (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1 No. | BI01010001010000000000000515BI0100001373 | ||
| 262 | 3.62 | One number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 200/5 A class 1.0 accuracy and 15 VA burden. | BI01010001010000000000000515BI0100001374 | ||
| 263 | 3.63 | One set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required | BI01010001010000000000000515BI0100001375 | ||
| 264 | 3.65 | OUTGOING | BI01010001010000000000000515BI0100001377 | ||
| 265 | 3.66 | 32Amp MC DP C Curve 10KA Breaking Capcity:- 4Nos. | BI01010001010000000000000515BI0100001378 | ||
| 266 | 3.67 | 100 Amps. 36KA, four Pole, thermal megnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 4 No. | BI01010001010000000000000515BI0100001379 | ||
| 267 | 3.68 | BUS BAR | BI01010001010000000000000515BI0100001380 | ||
| 268 | 3.69 | TPN Aluminium bus bars (having 100% neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set. | BI01010001010000000000000515BI0100001381 | ||
| 269 | 3.7 | Main LT Panel as above (NSI) | BI01010001010000000000000515BI0100001382 | 3 | Each |
| 270 | 3.71 | APFC Panel | BI01010001010000000000000515BI0100001383 | ||
| 271 | 3.72 | Supply, fixing, connecting and testing of OEM Manufactured APFC Panel with 7% copper reactor of capacity 30 KVAR (Output) @ 440Vac. The stage ratings shall be 1 X 2 KVAR + 1 x 3 KVAR + 2 x 12.5 KVAR, The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The APFC Panel shall be (Indoor) type floor mounted design, weather, and dust & vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. \nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\nAs equipment shall be comprising of the following:-\n | BI01010001010000000000000515BI0100001384 | ||
| 272 | 3.73 | (A) Insulated bus bar pan assembly made from copper and rated of 100 Amps capacity. The short circuit withstand capacity shall be 35 KA / 1 Sec (Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV. | BI01010001010000000000000515BI0100001385 | ||
| 273 | 3.74 | B) The incomer of the APFC Panel shall be a 100 Amp, MCCB, 3P, 35kA TMD type with O/L & S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\n | BI01010001010000000000000515BI0100001386 | ||
| 274 | 3.75 | (C) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1min) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993, 13341-1992 & IEC -60831-1&2.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only. \n | BI01010001010000000000000515BI0100001387 | ||
| 275 | 3.76 | (D) Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a Suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA. The MCCB shall be of certified design confirming to IEC 60947-1, 2 & 3. The de-tuning reactors (copper wound) shall be connected in series with each capacitor stage and shall be of iron cored type. The Detuned Reactor (Copper Wound) should be equipped with Thermal Switch inside the winding, which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\n | BI01010001010000000000000515BI0100001388 | ||
| 276 | 3.77 | (E) PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 12 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\n | BI01010001010000000000000515BI0100001389 | ||
| 277 | 3.78 | (F) Stage Contactor: The capacitor duty contactors shall be rated for 230 Volts AC and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. \nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only. \n | BI01010001010000000000000515BI0100001390 | ||
| 278 | 3.79 | (G) Reactor: - Harmonic block reactors copper wound with 7 % filtering factor shall be connected in series with each capacitor stage and shall be of iron cored type. The Reactor should be equipped with Thermal Switch inside the winding, which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only. | BI01010001010000000000000515BI0100001391 | ||
| 279 | 3.8 | (H) Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type-tested design and with temperature rise test report. | BI01010001010000000000000515BI0100001392 | ||
| 280 | 3.81 | APFC 30KVAR (NSI) | BI01010001010000000000000515BI0100001393 | 3 | Each |
| 281 | 3.82 | Distribution Panel (ACDB) - 4 nos per location | BI01010001010000000000000515BI0100001394 | ||
| 282 | 3.83 | Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN Copper bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The LT panel should have provision of following switchgear and accessories:- \n(Note:- (Note: All MCCBs shall be with ROM, Spreader terminals) | BI01010001010000000000000515BI0100001395 | ||
| 283 | 3.84 | INCOMER | BI01010001010000000000000515BI0100001396 | ||
| 284 | 3.85 | 100 Amps. 36KA, four Pole, thermal megnetic release , MCCB changeover switch (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1No. | BI01010001010000000000000515BI0100001397 | ||
| 285 | 3.86 | One number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 100/5 A class 1.0 accuracy and 15 VA burden. | BI01010001010000000000000515BI0100001398 | ||
| 286 | 3.87 | One set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as required | BI01010001010000000000000515BI0100001399 | ||
| 287 | 3.88 | OUTGOING | BI01010001010000000000000515BI0100001400 | ||
| 288 | 3.89 | 32 Amps MCB DP C CURVE 10 KA - 5 | BI01010001010000000000000515BI0100001401 | ||
| 289 | 3.9 | 32 Amps MCB TPN C CURVE 10 KA - 1 | BI01010001010000000000000515BI0100001402 | ||
| 290 | 3.91 | BUS BAR | BI01010001010000000000000515BI0100001403 | ||
| 291 | 3.92 | TPN Aluminium bus bars (having 100% neutral) of minimum of 100 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc.The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set. | BI01010001010000000000000515BI0100001404 | ||
| 292 | 3.93 | ACDB as described above (NSI) | BI01010001010000000000000515BI0100001405 | 3 | Each |
| 293 | 3.94 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | BI01010001010000000000000515BI0100001406 | ||
| 294 | 3.95 | 12 way , Double door (DSR E&M 2.3.3) | BI01010001010000000000000515BI0100001407 | 24 | each |
| 295 | 3.96 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | BI01010001010000000000000515BI0100001408 | ||
| 296 | 3.97 | Single pole (DSR E&M 2.10.1) | BI01010001010000000000000515BI0100001409 | 240 | each |
| 297 | 3.98 | Single pole and neutral (DSR E&M 2.10.2) | BI01010001010000000000000515BI0100001410 | 24 | each |
| 298 | 3.99 | LT CABLING, WIRING & EARTHING | BI01010001010000000000000515BI0100001411 | ||
| 299 | 4 | Supplying and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. | BI01010001010000000000000515BI0100001412 | ||
| 300 | 4.01 | for exhaust fan 20mm (DSR E&M 1.20.1) | BI01010001010000000000000515BI0100001413 | 2190 | Metre |
| 301 | 4.02 | for weighing room 25 mm (DSR E&M 1.20.3) | BI01010001010000000000000515BI0100001414 | 510 | Metre |
| 302 | 4.03 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. | BI01010001010000000000000515BI0100001415 | ||
| 303 | 4.04 | Group C (DSR E&M 1.8.3) | BI01010001010000000000000515BI0100001416 | 135 | point |
| 304 | 4.05 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) | BI01010001010000000000000515BI0100001417 | 645 | Meter |
| 305 | 4.06 | Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (DSR E&M 1.29) | BI01010001010000000000000515BI0100001418 | 60 | Each |
| 306 | 4.07 | Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR E&M 1.30) | BI01010001010000000000000515BI0100001419 | 30 | Each |
| 307 | 4.08 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (NSI) | BI01010001010000000000000515BI0100001420 | 10 | point |
| 308 | 4.09 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,\ and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. | BI01010001010000000000000515BI0100001421 | ||
| 309 | 4.1 | shed led lights (DSR E&M 1.54.3) | BI01010001010000000000000515BI0100001422 | 36 | Point |
| 310 | 4.11 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. | BI01010001010000000000000515BI0100001423 | ||
| 311 | 4.12 | Upto 35 sq. mm (DSR E&M 7.5.1) | BI01010001010000000000000515BI0100001424 | 980 | Metre |
| 312 | 4.13 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. | BI01010001010000000000000515BI0100001425 | ||
| 313 | 4.14 | Upto 35 sq. mm (DSR E&M 7.6.1) | BI01010001010000000000000515BI0100001426 | 340 | Metre |
| 314 | 4.15 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. | BI01010001010000000000000515BI0100001427 | ||
| 315 | 4.16 | 3.5 X 35 sq. mm (DSR E&M 9.2.32) | BI01010001010000000000000515BI0100001428 | 24 | Each |
| 316 | 4.17 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | BI01010001010000000000000515BI0100001429 | ||
| 317 | 4.18 | 3 x 2.5 sq. mm (DSR E&M 1.17.12) | BI01010001010000000000000515BI0100001430 | 780 | Metre |
| 318 | 4.19 | 3 x 1.5 sq. mm (DSR E&M 1.17.3) | BI01010001010000000000000515BI0100001431 | 900 | Metre |
| 319 | 4.2 | Supplying following sizes of FRLS PVC insulated armured aluminium conductor, 3.5 core cable in the existing surface/ recessed steel/ PVC conduit as required. | BI01010001010000000000000515BI0100001432 | ||
| 320 | 4.21 | 3.5 x 35 sq.mm (NSI) | BI01010001010000000000000515BI0100001433 | 340 | Metre |
| 321 | 4.22 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. | BI01010001010000000000000515BI0100001434 | ||
| 322 | 4.23 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (DSR E&M 1.7.9) | BI01010001010000000000000515BI0100001435 | 360 | Metre |
| 323 | 4.24 | Supplying , Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988\n | BI01010001010000000000000515BI0100001436 | ||
| 324 | 4.25 | 3 core 6 sq mm (NSI) | BI01010001010000000000000515BI0100001437 | 1410 | meter |
| 325 | 4.26 | 4 core 10 sq mm (NSI) | BI01010001010000000000000515BI0100001438 | 150 | meter |
| 326 | 4.27 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 5.2) | BI01010001010000000000000515BI0100001439 | 12 | Set |
| 327 | 4.28 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (DSR E&M 5.12) | BI01010001010000000000000515BI0100001440 | 300 | meter |
| 328 | 4.29 | Providing, Installing, Testing & Commissioning of 'Silent Type' Diesel Generating Set alongwith having Prime Power Rating of 62.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50 Hz. 3 phase system and for 0.85 Load Factor and consisting of the followings: and as per CPWD specifications:- | BI01010001010000000000000515BI0100001441 | ||
| 329 | 4.3 | Diesel Engine: | BI01010001010000000000000515BI0100001442 | ||
| 330 | 4.31 | Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at NTP conditions and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hour of | BI01010001010000000000000515BI0100001443 | ||
| 331 | 4.32 | Continuous operation. The engine will be fitted complete with all the required accessories. The Engine should be of Ashok Leyland / M&M / Greaves Cotton/ Kirloskar/ Cummins / Caterpillar / Volvo Penta / Perkins/ Mitsubishi make only. | BI01010001010000000000000515BI0100001444 | ||
| 332 | 4.33 | Engine mounted Instrument Panel fitted with and having digital display for following: | BI01010001010000000000000515BI0100001445 | ||
| 333 | 4.34 | Start-stop switch with key | BI01010001010000000000000515BI0100001446 | ||
| 334 | 4.35 | Water temperature indication | BI01010001010000000000000515BI0100001447 | ||
| 335 | 4.36 | Lubrication oil pressure indication | BI01010001010000000000000515BI0100001448 | ||
| 336 | 4.37 | Lubrication oil temperature indication | BI01010001010000000000000515BI0100001449 | ||
| 337 | 4.38 | Battery charging indication | BI01010001010000000000000515BI0100001450 | ||
| 338 | 4.39 | RPM indication | BI01010001010000000000000515BI0100001451 | ||
| 339 | 4.4 | Over speed indication | BI01010001010000000000000515BI0100001452 | ||
| 340 | 4.41 | Low lubricant Oil trip indication | BI01010001010000000000000515BI0100001453 | ||
| 341 | 4.42 | Engine Hours indication | BI01010001010000000000000515BI0100001454 | ||
| 342 | 4.43 | Alternator: | BI01010001010000000000000515BI0100001455 | ||
| 343 | 4.44 | Synchronous alternator rated at 62.5 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at NTP conditions. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation. The alternator should be of Stamford / Kirloskar / Leroy Somer / Crompton / Mitsubishi / Caterpillar make only. | BI01010001010000000000000515BI0100001456 | ||
| 344 | 4.45 | Base Frame & Foundation | BI01010001010000000000000515BI0100001457 | ||
| 345 | 4.46 | Both the engine and alternator shall be mounted on suitable base frame mode of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. | BI01010001010000000000000515BI0100001458 | ||
| 346 | 4.47 | Fuel Tank : | BI01010001010000000000000515BI0100001459 | ||
| 347 | 4.48 | Daily service fuel tank of suitable capacity / as per OEM fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. | BI01010001010000000000000515BI0100001460 | ||
| 348 | 4.49 | Exhaust System: | BI01010001010000000000000515BI0100001461 | ||
| 349 | 4.5 | Dry exhausts manifold with residential exhaust silencer and Catalytic convertor i/c all supporting structure. | BI01010001010000000000000515BI0100001462 | ||
| 350 | 4.51 | Starting System | BI01010001010000000000000515BI0100001463 | ||
| 351 | 4.52 | 12V DC starting system comprising of starter motors voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plate 180 AH lead acid type) as reqd. as per specification. | BI01010001010000000000000515BI0100001464 | ||
| 352 | 4.53 | Make of the Lead Acid battery Exide/ Standard / Amar raja only. | BI01010001010000000000000515BI0100001465 | ||
| 353 | 4.54 | Acoustic and weather proof enclosure (outdoor type) with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications to accommodate item (a) to (f) above as per CPCB-II norms, sound proofing done with high quality rock wool further covered with fiber glass sheet & perforated powder coated sheet as reqd. | BI01010001010000000000000515BI0100001466 | ||
| 354 | 4.55 | 62.5 KVA at 0.8 pf 415V 50Hz 3-Ø (NSI) | BI01010001010000000000000515BI0100001467 | 3 | each |
| 355 | 4.56 | Supply, assembly, erection, connecting, testing & commissioning of standard 4.0 metre high Post top (above ground) GRP Pole (Pressures as per IS 875 Part-3), with stiffeners, chain, Allen bolt, foundation bolts, pre fabricated plate, template, accessories, nut and washers, factory finish, Base plate. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening, an outdoor IP-66 rated junction/ looping box with Heavy duty 3 phase & Neutral, 20 Amp connector with 6A/10A DP MCB, double earthing arrangements, including all accessories complete as required as per specifications & approved by the Engineer Incharge. (NSI) | BI01010001010000000000000515BI0100001468 | 84 | Each |
| 356 | 4.57 | Supply, Installation, Testing & Commissioning of 2 MP Box camera with 1/3-inch CMOS, Active pixels 1920x1080; 2 MP at 30fps, Sensitivity – (3200K, reflectivity 89%, F1.4, 30IRE) Color 0.6 lx,Mono 0.008 lux ,With IR 0.0 lx, 120dB or better Wide Dynamic Range (WDR) according to IEC 62676p5, Stream 1 and Stream 2 Should be Configurable at 1080p 30 fps, H.265; M- JPEG, Multiple configurable streams in H.264 or H.265 and M-JPEG, White Balance, Day/ Night , Automatic Electronic Shutter (AES); Dynamic Noise Reduction, Video Analytics line crossing, loitering, counter, occupancy counter, object removal should all be included in the camera, Privacy Masking Twelve independent areas, fully programmable, Memory card slot, IR Range upto 60 metres , Automatic Varifocal 3 to 10 mm, ONVIF Profile S; ONVIF Profile G; IP67 & IK10. Housing, Mounting, Lens, IR Illuminator Should be of Same Make / OEM as of Camera Make. (NSI) | BI01010001010000000000000515BI0100001469 | 36 | Each |
| 357 | 4.58 | Supply, Installation, Testing & Commissioning of network recorder to a maximum of 16 IP cameras,The recorders can be installed with a maximum of 2 internal HDDs for videostorage. Option of a single HDD for storage, plus a DVD burner for video export. Max. capacity per HDD: 6 TB. The recorders comes with a built-in PoE+ switch. 4 alarm i/p & 2 relay o/p. Simultaneous 1/4/9/16 channels playback. H.265/H.264/MJPEG supported. iPhone/Android support. Maximum incoming bandwidth of 256 Mbps. Maximum recording bandwidth of 192 Mbps. 1 I/O for audio. 1 VGA & 1 HDMI outputs. CE, UL & FCC certified. (NSI) | BI01010001010000000000000515BI0100001470 | 3 | Each |
| 358 | 4.59 | Supply, Installation, Testing & Commissioning of 32\" LED display having 3 HDMi, 2 USB ports, Full HD, commercial LED of approved make. (NSI) | BI01010001010000000000000515BI0100001471 | 3 | Each |
| 359 | 4.6 | Supply, Installation, Testing & Commissioning of 24 port Giga PoE Switch with SFP Module of approved make. (NSI) | BI01010001010000000000000515BI0100001472 | 3 | Each |
| 360 | 4.61 | Supply, Installation, Testing & Commissioning of 6U Equipment Rack of approved make. (NSI) | BI01010001010000000000000515BI0100001473 | 3 | Each |
| 361 | 4.62 | Supply, Installation, Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. of approved make. (NSI) | BI01010001010000000000000515BI0100001474 | 1500 | Per/Mtr |
| 362 | 4.63 | Supply, Installation, Testing & Commissioning of CAT 6 UTP Cable of approved make. (NSI) | BI01010001010000000000000515BI0100001475 | 2400 | Per/Mtr |
| 363 | 4.64 | Supply and erection of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc of approved make. (NSI) | BI01010001010000000000000515BI0100001476 | 2100 | Per/Mtr |
| 364 | 4.65 | Three Phase LTCT Meter\n\nThe 3 Phase CT Operated Trivector Meter The meter has advanced data and tamper recording capabilities and is provided with communication ports.with following features:- Class 0.5s as per relevant IS and IEC Standards\n5A current rating\n3 Phase 4 Wire\n4 Quadrant Measurement\nAnti-tamper features\nSelf-diagnostic capability\nMultiple tariff / Time of day feature\nBidirectional Energy recording\nUpto 4 Maximum Demand registers\nLoad Survey (Interval Data) features\nUpto 12 reset backups\nOptical port/RS 232 / RS 485 / IR / IrDA / RF (2.4 GHz/865-867 MHz) (optional) (NSI) | BI01010001010000000000000515BI0100001477 | 3 | Job |
| 365 | 4.66 | CT ( current transformer) 100/5 amps (NSI) | BI01010001010000000000000515BI0100001478 | 9 | Job |
AI Tender Summary
Tender Timeline
Feb 03, 2020
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 11, 2020
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 11, 2020
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender