Housing Urban and Rular Development Government Departments Closing in 0 days TDR #23470942

Construction Of 3 Material Recovery Cum Transfer Stations Under Chandigarh Smart City

Issued by Government Departments · Chandigarh, Chandigarh
Tender Value
17.84 Crore
Estimated cost
Bid Submission
11 Feb 2020
0 days left
EMD
27.85 Lakhs
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of 3 Material Recovery Cum Transfer Stations Under Chandigarh Smart City

BOQ

Name of Work: Construction of 3 Material Recovery cum Trasnfer Station Under Chandigarh Smart City
Sl.No.Item DescriptionItem Code / MakeQuantityUnits
11.01Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.BI01010001010000000000000515BI0100001113
21.02All kinds of soil (DSR 2.6.1)BI01010001010000000000000515BI01000011143656.75Cum
31.03Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.BI01010001010000000000000515BI0100001115
41.04All kinds of soil (DSR 2.26.1)BI01010001010000000000000515BI0100001116880.652Cum
51.05Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (DSR 2.25)BI01010001010000000000000515BI01000011172898.26Cum
61.06Carriage of earth by mechanical transport including loading, unloading and stacking upto 12 km in all respect and direction by Engineer-in-Charge. (DSR 1.1.2)BI01010001010000000000000515BI0100001118505.665Cu.m
71.07Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :BI01010001010000000000000515BI0100001119
81.081:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) (DSR 4.1.10)BI01010001010000000000000515BI010000112072.953Cu.m
91.091:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) (DSR 4.1.5)BI01010001010000000000000515BI010000112128.555Cu.m
101.11:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) (DSR 4.1.3)BI01010001010000000000000515BI01000011220.304Cu.m
111.11Providing and laying in position ready mixed M-20 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge.\n(Note :- Cement content considered in this item is @ 300 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately).BI01010001010000000000000515BI0100001123
121.12All works upto plinth level (NSI)BI01010001010000000000000515BI0100001124383.282Cum
131.13All works above plinth level upto floor five level (NSI)BI01010001010000000000000515BI010000112583.112Cum
141.14Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). \n(Note:- Cement content considered in this item is @ 300 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (NSI)BI01010001010000000000000515BI0100001126336Cum
151.15Centering and shuttering including strutting, propping etc. and removal of form for :BI01010001010000000000000515BI0100001127
161.16Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1)BI01010001010000000000000515BI0100001128789.384Sq.m
171.17Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2)BI01010001010000000000000515BI0100001129708Sq.m
181.18Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6)BI01010001010000000000000515BI0100001130739.2Sq.m
191.19Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3)BI01010001010000000000000515BI0100001131487.486Sq.m
201.2Edges of slabs and breaks in floors and wallsBI01010001010000000000000515BI0100001132
211.21Under 20 cm wide (DSR 5.9.16.1)BI01010001010000000000000515BI0100001133380.79mtr
221.22Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.\n(Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately).BI01010001010000000000000515BI0100001134
231.23All works upto plinth level (DSR 5.33.1)BI01010001010000000000000515BI010000113587Cum
241.24Extra for providing richer mixes at all floor levels.\nNote:- Excess/less cement over the specified cement content used is payable /recoverable separately.BI01010001010000000000000515BI0100001136
251.25Providing M-30 grade concrete instead of M-25 grade RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum) (DSR 5.34.1)BI01010001010000000000000515BI010000113787Cum
261.26Excess/ less cement used as per design mix is payable/recoverable (NSI)BI01010001010000000000000515BI01000011382134.28Quintal
271.27Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:BI01010001010000000000000515BI0100001139
281.28Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2)BI01010001010000000000000515BI0100001140346.988Cu.m
291.29Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :BI01010001010000000000000515BI0100001141
301.3Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1)BI01010001010000000000000515BI0100001142230.251Cum
311.31Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2)BI01010001010000000000000515BI0100001143204.505Cum
321.32Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.BI01010001010000000000000515BI0100001144
331.33Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2)BI01010001010000000000000515BI010000114537.377Sq.m
341.34Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (DSR 2.27)BI01010001010000000000000515BI01000011463580.96Cu.m
351.35Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. (DSR 16.80)BI01010001010000000000000515BI01000011471442.03Cum
361.36Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.BI01010001010000000000000515BI0100001148
371.37With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 (DSR 16.78.1)BI01010001010000000000000515BI0100001149212.1Cum
381.38With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2)BI01010001010000000000000515BI01000011501879.55Cu.m
391.39Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.79)BI01010001010000000000000515BI01000011511879.55Cu.m
401.4Providing and laying design mix cement concrete of M-40 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).BI01010001010000000000000515BI0100001152
411.41Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer \nNote:- Cement content considered in M-40 is @ 360 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. (NSI)BI01010001010000000000000515BI01000011531252.02Cu.m
421.42Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).\nNote:- Cement content considered in M-30 is @ 340 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately.BI01010001010000000000000515BI0100001154
431.43Cement concrete manufactured in automatic batching plant (RMC plant) i/c transportation to site in transit mixer (DSR 16.43.2)BI01010001010000000000000515BI01000011551296.04Cu.m
441.44Providing and laying in position bitumen hot sealing compound for expansion joints etc.BI01010001010000000000000515BI0100001156
451.45Using grade ‘A’ sealing compound. (DSR 16.46.1)BI01010001010000000000000515BI0100001157600per cm depth per cm width per metre\nlength
461.46Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.BI01010001010000000000000515BI0100001158
471.47Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6)BI01010001010000000000000515BI010000115939831.6KG
481.48Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.BI01010001010000000000000515BI0100001160
491.49Mild steel and Medium Tensile steel bars (DSR 5.22A.1)BI01010001010000000000000515BI01000011611320KG
501.5Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.2)BI01010001010000000000000515BI0100001162406216KG
511.51Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineering- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (DSR 12.50)BI01010001010000000000000515BI010000116312984.7Sq.m
521.52Supply and installation of 2mm thick clear embossed Polycarbonate Sheet (Polycarbonate profile to match with standing seam profile with side laps to be clamped with bare precoated sheets of 0.5mm,(tct) which can be further seamed with metal roof sheets. Product required is clear embossed with both sides UV stabilizer, having at leasts 60 - 80% transparency, conforming to the relevant IS Code including cutting to shape and size required including necessary sealants. Including all materials, tools & tackles, labours etc. in complete all respect as per the direction of Engineer- in-Charge. (NSI)BI01010001010000000000000515BI0100001164241.08Sq.m
531.53Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws completeBI01010001010000000000000515BI0100001165
541.54Gutter (600 mm over all girth) (DSR 12.51.6)BI01010001010000000000000515BI0100001166633.6Metre
551.55Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR 10.1)BI01010001010000000000000515BI01000011671354.36Kg
561.56Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.BI01010001010000000000000515BI0100001168
571.57160 mm diameter (NSI)BI01010001010000000000000515BI0100001169913.77Metre
581.58Providing and fixing on wall face unplasticised - PVC moulded 160 mm dis Shoe (Plain) for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (NSI)BI01010001010000000000000515BI010000117099Each
591.59Supplying, installation, testing & commissioning of belt conveyor system with suitable swivel/ rotatable chute to unload garbage form belt conveyer to tipcart such that there is no interference with tipcart while tipping with geared motor of suitable capacity.\nDimensions – i) Length 30.00mtr. ii) Width 1.50mtr. iii) Height above finish floor level of platform Minimum 1.20mrt or suitable as per machine requirement. The belt should be 3 ply belt, 125X75 mm channel X head pulley rubberized, tail pulley carrying idlers 90 mm dia return rollers impact idlers screw tensioning arrangement complete with two no. coats of paint including modular type Electrical Panel of suitable capacity to control the operation of Belt Conveyor system as per relevant BIS Codes. (NSI)BI01010001010000000000000515BI01000011716Each
601.6Construction of M30 grade RCC precast/ Prestressed Boundary wall all complete as per specification. (NSI)BI01010001010000000000000515BI01000011723138.71Sq.m
611.61Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).\n(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR 16.75)BI01010001010000000000000515BI0100001173565.6cum
621.62Supply, Installation, Testing & Commissioning of 10 ton capacity electrical weighing bridge with software for automatic transfer of data for day to day calculation of weight all complete as per technical Specifications. (NSI)BI01010001010000000000000515BI01000011749Each
631.63Supplying, installation, testing & commissioning of RFID enabled, antic rash beam sensor automatic hydraulic boom barrier with UHF Tag all complete as per specification. (200 nos UHF Tag for each station) (NSI)BI01010001010000000000000515BI01000011753Job
641.64Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (DSR 2.25(a))BI01010001010000000000000515BI010000117640609.3Cu.m
651.65Supplying, erecting & commissioning of automatic motorised steel gate all complete as per specification. (NSI)BI01010001010000000000000515BI01000011776Each
661.66Supplying, fixing, testing & commissioning of automatic truck tyre washing system including Wash Platform, Side Screens, Wash Pump, Recycle Water tank, Entry Vehicle Detection sensor etc. all complete as per specification. (NSI)BI01010001010000000000000515BI01000011781Job
671.67Supplying, fixing, testing & commissioning of Cold High Pressure truck tyre washing system with Foam sprayer etc. all complete as per specification. (NSI)BI01010001010000000000000515BI01000011792Job
681.68Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in foundation, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (NSI)BI01010001010000000000000515BI01000011802.222Cu.m
691.69Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. (DSR 6.15)BI01010001010000000000000515BI010000118137.377Sq.m
701.712 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand (DSR 13.1.1)BI01010001010000000000000515BI01000011821548.2Sqm
711.7120 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) (DSR 13.3.2)BI01010001010000000000000515BI01000011831713.78Sqm
721.726 mm cement plaster of mix :BI01010001010000000000000515BI0100001184
731.731:3 (1 cement : 3 fine sand) (DSR 13.16.1)BI01010001010000000000000515BI0100001185378.122Sq.m
741.74Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR 13.80)BI01010001010000000000000515BI01000011861926.32Sqm
751.75Distempering with oil bound washable distemper of approved brand and manufacture to give an even shadeBI01010001010000000000000515BI0100001187
761.76New work (two or more coats) over and including water thinnable priming coat with cement primer (DSR 13.41.1)BI01010001010000000000000515BI01000011881926.32Sqm
771.77Finishing walls with water proofing cement paint of required shade :BI01010001010000000000000515BI0100001189
781.78New work (Two or more coats applied @ 3.84 kg/10 sqm) (DSR 13.44.1)BI01010001010000000000000515BI01000011901713.78Sqm
791.79Finishing walls with Acrylic Smooth exterior paint of required shade :BI01010001010000000000000515BI0100001191
801.8New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) (DSR 13.46.1)BI01010001010000000000000515BI01000011921713.78Sqm
811.81Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR 8.31)BI01010001010000000000000515BI0100001193309.324Sqm
821.82Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR 11.37)BI01010001010000000000000515BI010000119476.517Sqm
831.83Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.BI01010001010000000000000515BI0100001195
841.84Size of Tile 800x800 mm (DSR 11.41.3)BI01010001010000000000000515BI0100001196218.412Sqm
851.85Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.BI01010001010000000000000515BI0100001197
861.8680x1.25 mm M.S. laths with 1.25 mm thick top cover (DSR 10.6.1)BI01010001010000000000000515BI010000119814.4Sqm
871.87Door & WindowBI01010001010000000000000515BI0100001199
881.88Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :\nPowder coated aluminium (minimum\nthickness of powder coating 50 micron)BI01010001010000000000000515BI0100001200
891.89For fixed portionBI01010001010000000000000515BI0100001201
901.9Powder coated aluminium (minimum thickness of powder coating 50 micron)\nDouble Rebate (DSR 21.1.1.2)BI01010001010000000000000515BI0100001202425.114Kg
911.91Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.BI01010001010000000000000515BI0100001203
921.9235 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1)BI01010001010000000000000515BI010000120431.5sqm
931.93Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :BI01010001010000000000000515BI0100001205
941.9435 mm thick shuttersBI01010001010000000000000515BI0100001206
951.95With ISI marked stainless steel butt hinges of\nrequired sizeBI01010001010000000000000515BI0100001207
961.96Kiln seasoned selected class of sheesham wood (DSR 9.27.1.2.3)BI01010001010000000000000515BI010000120831.5sqm
971.97Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 0x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). (DSR 9.53)BI01010001010000000000000515BI0100001209264Each
981.98Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).BI01010001010000000000000515BI0100001210
991.99Kiln seasoned and chemically treated hollock wood (DSR 9.1.3)BI01010001010000000000000515BI01000012110.277cum
1002Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.BI01010001010000000000000515BI0100001212
1012.01Kiln seasoned selected planks of sheesham woodBI01010001010000000000000515BI0100001213
1022.0235 mm thick (DSR 9.9.3.1)BI01010001010000000000000515BI010000121476.68sqm
1032.03Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR 9.14)BI01010001010000000000000515BI010000121576.68Sqm
1042.04Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. (DSR 9.121)BI01010001010000000000000515BI0100001216105.45metre
1052.0530 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. (DSR 9.122.1)BI01010001010000000000000515BI010000121736.225Sqm
1062.06Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :BI01010001010000000000000515BI0100001218
1072.07150x10 mm (DSR 9.97.4)BI01010001010000000000000515BI010000121966Each
1082.08200x10 mm (DSR 9.97.3)BI01010001010000000000000515BI010000122078Each
1092.09Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :BI01010001010000000000000515BI0100001221
1102.1125 mm (DSR 9.100.1)BI01010001010000000000000515BI010000122248Each
1112.11Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :BI01010001010000000000000515BI0100001223
1122.12300x16 mm (DSR 9.96.1)BI01010001010000000000000515BI010000122424each
1132.13Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.BI01010001010000000000000515BI0100001225
1142.14Single rubber stopper (DSR 9.101.1)BI01010001010000000000000515BI010000122618Each
1152.15Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR 9.84)BI01010001010000000000000515BI010000122718Each
1162.16Water Supply PlumbingBI01010001010000000000000515BI0100001228
1172.17Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :BI01010001010000000000000515BI0100001229
1182.18W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1)BI01010001010000000000000515BI010000123015Each
1192.19Providing and fixing 8 mm dia C.P. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (DSR 17.16A)BI01010001010000000000000515BI010000123115Each
1202.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:BI01010001010000000000000515BI0100001232
1212.21White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4)BI01010001010000000000000515BI010000123315Each
1222.22Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR 17.70)BI01010001010000000000000515BI010000123424each
1232.23Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backingBI01010001010000000000000515BI0100001235
1242.24Rectangular shape 453x357 mm (DSR 17.32.2)BI01010001010000000000000515BI010000123615Each
1252.25Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.BI01010001010000000000000515BI0100001237
1262.2615 mm nominal bore (DSR 18.52.1)BI01010001010000000000000515BI010000123830each
1272.27Providing and fixing C.P. brass angular stop cock\n15mm nominal bore (NSI)BI01010001010000000000000515BI010000123915each
1282.28Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (DSR 18.15.1)BI01010001010000000000000515BI010000124015each
1292.29Providing and fixing partitions for different type of urinals.\nVitreous white Chinaware Partition\nLarge partitions size 835mm x 355mm (NSI)BI01010001010000000000000515BI010000124112Each
1302.3Providing and fixing in position best Indian make soap dish fixed into wall with C.P brass screws and complete in all respects including cutting and making good the walls etc.\nC.P. brass soap dish Small (NSI)BI01010001010000000000000515BI010000124212each
1312.31Providing and fixing in position towel rails / ring fixed in with rawl plugs embedded in walls with brass screws, complete in all respects including cutting and making good the walls etc.\nC.P brass towel ring (NSI)BI01010001010000000000000515BI010000124312each
1322.32Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :BI01010001010000000000000515BI0100001244
1332.33Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern (DSR 17.4.3)BI01010001010000000000000515BI01000012459Each
1342.34Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :BI01010001010000000000000515BI0100001246
1352.3515 mm dia nominal bore (DSR 18.11.1)BI01010001010000000000000515BI010000124715metre
1362.3620 mm dia nominal bore (DSR 18.11.2)BI01010001010000000000000515BI0100001248150metre
1372.37Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.BI01010001010000000000000515BI0100001249
1382.3825 mm dia nominal bore (DSR 18.10.3)BI01010001010000000000000515BI010000125045metre
1392.39Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.BI01010001010000000000000515BI0100001251
1402.450 mm dia nominal bore (DSR 18.12.6)BI01010001010000000000000515BI0100001252900metre
1412.4125 mm dia nominal bore (DSR 18.12.3)BI01010001010000000000000515BI0100001253750metre
1422.42Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :BI01010001010000000000000515BI0100001254
1432.4350 to 80 mm nominal bore (DSR 18.13.2)BI01010001010000000000000515BI01000012556each
1442.44Providing, installation, testing & commissioning of Centrifugal pump self priming all complete as per RFP. (NSI)BI01010001010000000000000515BI01000012563Each
1452.45Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :BI01010001010000000000000515BI0100001257
1462.4615 mm nominal bore (DSR 18.46.1)BI01010001010000000000000515BI01000012586each
1472.4720 mm nominal bore (DSR 18.46.2)BI01010001010000000000000515BI01000012596each
1482.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary oles for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR 18.48)BI01010001010000000000000515BI010000126012000per litre
1492.49Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :BI01010001010000000000000515BI0100001261
1502.550 mm nominal bore (DSR 18.17.4)BI01010001010000000000000515BI01000012626each
1512.51Providing and fixing gun metal non- return valve of approved quality (screwed end) :BI01010001010000000000000515BI0100001263
1522.5250 mm nominal boreBI01010001010000000000000515BI0100001264
1532.53Horizontal (DSR 18.19.4.1)BI01010001010000000000000515BI01000012656each
1542.54Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks (DSR 18.76.1)BI01010001010000000000000515BI01000012666each
1552.55Sanitary Installation PlumbingBI01010001010000000000000515BI0100001267
1562.56Providing and fixing soil, waste and vent pipes :BI01010001010000000000000515BI0100001268
1572.57100 mm diaBI01010001010000000000000515BI0100001269
1582.58Sand cast iron S&S pipe as per IS: 1729 (DSR 17.35.1.1)BI01010001010000000000000515BI0100001270270metre
1592.5975 mm diaBI01010001010000000000000515BI0100001271
1602.6Sand cast iron S&S pipe as per IS: 1729 (DSR 17.35.2.1)BI01010001010000000000000515BI0100001272150metre
1612.61Providing and fixing plain bend of required degree.BI01010001010000000000000515BI0100001273
1622.62100 mm diaBI01010001010000000000000515BI0100001274
1632.63Sand cast iron S&S as per IS - 1729 (DSR 17.39.1.1)BI01010001010000000000000515BI010000127515Each
1642.6475 mm diaBI01010001010000000000000515BI0100001276
1652.65Sand cast iron S&S as per IS - 1729 (DSR 17.39.2.1)BI01010001010000000000000515BI010000127715Each
1662.66Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter :BI01010001010000000000000515BI0100001278
1672.67100 mm (DSR 17.58.1)BI01010001010000000000000515BI010000127918Each
1682.6875 mm (DSR 17.58.2)BI01010001010000000000000515BI010000128018Each
1692.69Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :BI01010001010000000000000515BI0100001281
1702.7100 mm inlet and 75 mm outletBI01010001010000000000000515BI0100001282
1712.71Sand cast iron S&S as per IS - 3989 (DSR 17.60.2.1)BI01010001010000000000000515BI010000128321Each
1722.72Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :BI01010001010000000000000515BI0100001284
1732.73With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 (DSR 18.36.1)BI01010001010000000000000515BI01000012859Each
1742.74Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :BI01010001010000000000000515BI0100001286
1752.75150 mm diameter (DSR 19.1.1)BI01010001010000000000000515BI0100001287300metre
1762.76Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :BI01010001010000000000000515BI0100001288
1772.77150 mm diameter S.W. pipe (DSR 19.2.1)BI01010001010000000000000515BI0100001289300metre
1782.78Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :BI01010001010000000000000515BI0100001290
1792.79For pipes 100 to 250 mm diameter (DSR 19.21.1)BI01010001010000000000000515BI01000012913Each
1802.8Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :BI01010001010000000000000515BI0100001292
1812.81300 mm dia. R.C.C. pipe (DSR 19.6.4)BI01010001010000000000000515BI0100001293900metre
1822.82Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :BI01010001010000000000000515BI0100001294
1832.83With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.27.1)BI01010001010000000000000515BI010000129521Each
1842.84Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :BI01010001010000000000000515BI0100001296
1852.85Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :BI01010001010000000000000515BI0100001297
1862.86Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :BI01010001010000000000000515BI0100001298
1872.87With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.7.1.1)BI01010001010000000000000515BI010000129921Each
1882.88Extra for depth for manholes :BI01010001010000000000000515BI0100001300
1892.89Size 90x80 cmBI01010001010000000000000515BI0100001301
1902.9With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.8.1.1)BI01010001010000000000000515BI010000130221metre
1912.91Supply, Installation, testing and commissioning of 36 W LED StreetLight to installed with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. The luminarie should have (NSI)BI01010001010000000000000515BI010000130384Each
1922.92Main Housing, frame : Powder coated, pressure die-cast Aluminum housing.BI01010001010000000000000515BI0100001304
1932.93Front Cover: Clear toughened glass with synthetic rubber gasket.BI01010001010000000000000515BI0100001305
1942.94LED: LM80 certified high power LEDBI01010001010000000000000515BI0100001306
1952.95LED make Osram/Cree/NichiaBI01010001010000000000000515BI0100001307
1962.96Lens: Suitable secondary lens for better light distributionBI01010001010000000000000515BI0100001308
1972.97Gear: Integral, Electronic, constant current driver.BI01010001010000000000000515BI0100001309
1982.98Internal Wiring: Teflon insulated, Cu. Conductor.BI01010001010000000000000515BI0100001310
1992.99Hardware: SS & Ms zinc plated & passivated.BI01010001010000000000000515BI0100001311
2003Ingress protection: IP66BI01010001010000000000000515BI0100001312
2013.01Impact resistance: IK07BI01010001010000000000000515BI0100001313
2023.02Lumen maintenance: 50,000 Hrs @ L70BI01010001010000000000000515BI0100001314
2033.03Operating temperature: -10°C to 50°CBI01010001010000000000000515BI0100001315
2043.04Rated voltage & frequency: 240V, 50Hz ACBI01010001010000000000000515BI0100001316
2053.05Wattage 36W±10%BI01010001010000000000000515BI0100001317
2063.06Current <0.17ABI01010001010000000000000515BI0100001318
2073.07Pf > 0.95BI01010001010000000000000515BI0100001319
2083.08THD < 10%BI01010001010000000000000515BI0100001320
2093.09Efficacy > 100 lm/WBI01010001010000000000000515BI0100001321
2103.1Lumen=3600BI01010001010000000000000515BI0100001322
2113.11CCT 5700- 6500KBI01010001010000000000000515BI0100001323
2123.12CRI > 70BI01010001010000000000000515BI0100001324
2133.13Supply, Installation, testing and commissioning of 20W LED Batten Light to installed with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. The luminarie should have (NSI)BI01010001010000000000000515BI010000132554Each
2143.14Main Housing, frame : Powder coated, Al. extrusion.BI01010001010000000000000515BI0100001326
2153.15Front Cover: Diffused PS/PMMA.BI01010001010000000000000515BI0100001327
2163.16LED: LM80 certified Osram/Cree/Nichia makeBI01010001010000000000000515BI0100001328
2173.17Gear: Electronic constant current driver.BI01010001010000000000000515BI0100001329
2183.18Internal Wiring: Teflon insulated, Cu. Conductor.BI01010001010000000000000515BI0100001330
2193.19Hardware: Ms zinc plated & passivated.BI01010001010000000000000515BI0100001331
2203.2Ingress protection: IP20BI01010001010000000000000515BI0100001332
2213.21Lumen maintenance: 50,000 Hrs @ L70BI01010001010000000000000515BI0100001333
2223.22Operating Voltage range: 140V - 270V ACBI01010001010000000000000515BI0100001334
2233.23Operating temperature: -10°C to 55°CBI01010001010000000000000515BI0100001335
2243.24Rated voltage & frequency: 240V, 50Hz ACBI01010001010000000000000515BI0100001336
2253.25Rated voltage & frequency: 240V, 50Hz ACBI01010001010000000000000515BI0100001337
2263.26Wattage 20W±10%BI01010001010000000000000515BI0100001338
2273.27Current <0.09ABI01010001010000000000000515BI0100001339
2283.28Pf > 0.95BI01010001010000000000000515BI0100001340
2293.29Ithd < 10%BI01010001010000000000000515BI0100001341
2303.3Efficacy > 100 lm/WBI01010001010000000000000515BI0100001342
2313.31Lumen= 2000 LmBI01010001010000000000000515BI0100001343
2323.32CCT 5700K- 6500 KBI01010001010000000000000515BI0100001344
2333.33CRI > 80BI01010001010000000000000515BI0100001345
2343.34Supply, Installation, testing and commissioning of 120 W LED High bay light to installed GI Bracket with suitable nut bolt.The job includes the cost of testing, commissioning and making connections. the job includes all labour and petty material required to install the fitting to entire satisfaction of work. (NSI)BI01010001010000000000000515BI0100001346108Each
2353.35System Wattage 120W±10%BI01010001010000000000000515BI0100001347
2363.36Lamp Type LM80 certifiedBI01010001010000000000000515BI0100001348
2373.37Optic Suitable lens cluster for optimum light distributionBI01010001010000000000000515BI0100001349
2383.38System Lumen efficacy 120 lm/W (min.)BI01010001010000000000000515BI0100001350
2393.39Lumen= 17400 LmBI01010001010000000000000515BI0100001351
2403.4Internal Wiring: Teflon insulated, Cu. Conductor.BI01010001010000000000000515BI0100001352
2413.41Colour temperature 5700KBI01010001010000000000000515BI0100001353
2423.42CRI >70BI01010001010000000000000515BI0100001354
2433.43THD<10%BI01010001010000000000000515BI0100001355
2443.44PF>0.95BI01010001010000000000000515BI0100001356
2453.45Surge protection 5 KV Internal + 10 KV SPDBI01010001010000000000000515BI0100001357
2463.46Rated Voltage & frequency 240V, 50HzBI01010001010000000000000515BI0100001358
2473.47Housing Al. PDC HousingBI01010001010000000000000515BI0100001359
2483.48Front cover Toughened glassBI01010001010000000000000515BI0100001360
2493.49Lumen maintenance 50,000 Hrs @ L70BI01010001010000000000000515BI0100001361
2503.5Operating temperature -10°C to +50°CBI01010001010000000000000515BI0100001362
2513.51Ingress Protection IP65BI01010001010000000000000515BI0100001363
2523.52Impact Resistance IK05BI01010001010000000000000515BI0100001364
2533.53Supply,installation, testing & commissioning of 1200mm sweep celing fan BEE 5 Star rated,with copper widing complete with Aluminium blades, plastic canopies 2 nos. double ball bearing, MS hanging rod (as per site requirement) condenser, reels, clamps, etc. the body of fan and blades includes the cost of making necessary connections from adjacent light points with 1.5 sqmm single core copper conductor cable The job includes the cost of carriage, all labour and petty material required to complete the job to the entire satisfaction of Engineer in-charge. (NSI)BI01010001010000000000000515BI010000136527Each
2543.54Supply & Erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operatio, epoxy powder coating along with metallic louver to be installed in existing opening including cost of making holes to suit the size of above fan making good damage, carriage charges connection, testing, commissioning, etc. as required to complete the job to the entire satisfaction of EICBI01010001010000000000000515BI0100001366
2553.55Size 12 inches (300 mm) sweep, single phase, 900 RPM Heavy duty Exhaust fan (NSI)BI01010001010000000000000515BI01000013679Each
2563.56Size 24 inches (600 mm) sweep, three phase, 900 RPM Heavy duty Exhaust fan (NSI)BI01010001010000000000000515BI010000136830Each
2573.57MAIN LT PANEL - 1 no per locationBI01010001010000000000000515BI0100001369
2583.58Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN Copper bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The LT panel should have provision of following switchgear and accessories:- \n(Note:- (Note: All MCCBs shall be with ROM, Spreader terminals)BI01010001010000000000000515BI0100001370
2593.59INCOMERBI01010001010000000000000515BI0100001371
2603.6200 Amps. 36KA, four Pole, thermal megnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1 No.BI01010001010000000000000515BI0100001372
2613.61200 Amps. 36KA, four Pole, thermal megnetic release , MCCB changeover switch (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1 No.BI01010001010000000000000515BI0100001373
2623.62One number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 200/5 A class 1.0 accuracy and 15 VA burden.BI01010001010000000000000515BI0100001374
2633.63One set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as requiredBI01010001010000000000000515BI0100001375
2643.65OUTGOINGBI01010001010000000000000515BI0100001377
2653.6632Amp MC DP C Curve 10KA Breaking Capcity:- 4Nos.BI01010001010000000000000515BI0100001378
2663.67100 Amps. 36KA, four Pole, thermal megnetic release , MCCB (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 4 No.BI01010001010000000000000515BI0100001379
2673.68BUS BARBI01010001010000000000000515BI0100001380
2683.69TPN Aluminium bus bars (having 100% neutral) of minimum of 250 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec. The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set.BI01010001010000000000000515BI0100001381
2693.7Main LT Panel as above (NSI)BI01010001010000000000000515BI01000013823Each
2703.71APFC PanelBI01010001010000000000000515BI0100001383
2713.72Supply, fixing, connecting and testing of OEM Manufactured APFC Panel with 7% copper reactor of capacity 30 KVAR (Output) @ 440Vac. The stage ratings shall be 1 X 2 KVAR + 1 x 3 KVAR + 2 x 12.5 KVAR, The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The APFC Panel shall be (Indoor) type floor mounted design, weather, and dust & vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 40°C, Maximum altitude: 2000 m. \nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\nAs equipment shall be comprising of the following:-\nBI01010001010000000000000515BI0100001384
2723.73(A) Insulated bus bar pan assembly made from copper and rated of 100 Amps capacity. The short circuit withstand capacity shall be 35 KA / 1 Sec (Icw) for the main bus bar and the rated impulse withstand voltage shall be 6 KV.BI01010001010000000000000515BI0100001385
2733.74B) The incomer of the APFC Panel shall be a 100 Amp, MCCB, 3P, 35kA TMD type with O/L & S/C protection, Ics = 100% Icu, MCCB shall have standard extended rotary handle, spreaders, phase barrier.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\nBI01010001010000000000000515BI0100001386
2743.75(C) Capacitor Units: The capacitor unit shall be metalized polypropylene film with Zn / Al alloy. The capacitors shall be encapsulated in an aluminium can. The capacitor unit shall have a rated voltage of 525V and shall have a maximum over current capacity of: 2.5 In. The capacitor unit shall have a built in 3 phase over pressure protection and shall have discharge resistors (50V in 1min) factory fitted and shall be tamper proof. Capacitance Tolerance -5%, +10%. Maximum permissible over voltage 1.1 x Un, 8 h every 24 h. The capacitor unit shall be of certified design confirming to IS-13340-1993, 13341-1992 & IEC -60831-1&2.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only. \nBI01010001010000000000000515BI0100001387
2753.76(D) Short-circuit and Overload Protection: Each stage of the APFC Panel shall have a Suitably rated MCCB for short-circuit and overload protection. The over-current setting shall be adjustable & Breaking capacity Ics=> 36kA. The MCCB shall be of certified design confirming to IEC 60947-1, 2 & 3. The de-tuning reactors (copper wound) shall be connected in series with each capacitor stage and shall be of iron cored type. The Detuned Reactor (Copper Wound) should be equipped with Thermal Switch inside the winding, which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\nBI01010001010000000000000515BI0100001388
2763.77(E) PF Regulator/ APFC Relay: Advanced Range PF Regulator / micro-processor based APFC relay having 12 steps with a LCD Display, Voltage Range: 90V - 550V, 50 / 60Hz, CT Input: 1A/5A with a built in RS 485 communication port. The PF Regulator shall be of certified design confirming to IEC 61326.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.\nBI01010001010000000000000515BI0100001389
2773.78(F) Stage Contactor: The capacitor duty contactors shall be rated for 230 Volts AC and shall be 3-pole type and shall be employed for switching 'on' and switching 'off' operations in capacitor banks. The contactor shall be AC3b type. The contactor shall be of certified design confirming to IEC 60947-1 & 4-1. \nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only. \nBI01010001010000000000000515BI0100001390
2783.79(G) Reactor: - Harmonic block reactors copper wound with 7 % filtering factor shall be connected in series with each capacitor stage and shall be of iron cored type. The Reactor should be equipped with Thermal Switch inside the winding, which should cut-off the respective contactor in case of Over-temperature. Tolerance of reactors shall not exceed +/-3% of rated value.\nApproved Makes- ABB / Schneider / Siemens / L&T/ Legrand make only.BI01010001010000000000000515BI0100001391
2793.8(H) Ventilating fans of required size shall be used to dissipate the heat produced by the capacitor bank components like the capacitor units, reactors, contactors, breakers etc. The capacitor banks should be of type-tested design and with temperature rise test report.BI01010001010000000000000515BI0100001392
2803.81APFC 30KVAR (NSI)BI01010001010000000000000515BI01000013933Each
2813.82Distribution Panel (ACDB) - 4 nos per locationBI01010001010000000000000515BI0100001394
2823.83Fabrication, Supplying, Installation, Testing and Commissioning of electric control panel of cubical construction, wall/floor mounted type, fabricated out of 2 mm thick CRCA sheet, compartmentalized with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, having suitable capacity TPN Copper bus bars, DMC/ SMC bus bar supports, base frame of MS channel 100mm x 50mm x 6mm size, having switchgears and accessories , internal wiring with 2.5 sq.mm PVC insulated single core cable, common copper earth bar of size 25 x 5 mm over the entire width of panel and 2 nos. earth studs, cable entry from the top & bottom, cable gland plates, numbering, labeling etc. complete in all respect, suitable for operation on 415 V, 3 phase, 50 Hz. AC supply with protection class IP 42 as required. The job includes the cost of MCCB, accessories, interconnection with solid connection, carriage and installation of cubical panel at site to the entire satisfaction of Engineer in charge. The LT panel should have provision of following switchgear and accessories:- \n(Note:- (Note: All MCCBs shall be with ROM, Spreader terminals)BI01010001010000000000000515BI0100001395
2833.84INCOMERBI01010001010000000000000515BI0100001396
2843.85100 Amps. 36KA, four Pole, thermal megnetic release , MCCB changeover switch (Ics = Icu at 415 V) with O/L, S/C & earth fault protection :- 1No.BI01010001010000000000000515BI0100001397
2853.86One number intelligent multifunction digital meter to read V, A, KVA, KWH,THD, PF Hz etc. with 3 Nos. resin cast CTs of 100/5 A class 1.0 accuracy and 15 VA burden.BI01010001010000000000000515BI0100001398
2863.87One set of phase indication LED lamps with 2 Amps. Back up MCB, breaker ON/OFF indicating light with MCB, test terminal block set, circuits as per standard practice and auxiliary contact contactors for positive electrical interlocking of breakers etc. as requiredBI01010001010000000000000515BI0100001399
2873.88OUTGOINGBI01010001010000000000000515BI0100001400
2883.8932 Amps MCB DP C CURVE 10 KA - 5BI01010001010000000000000515BI0100001401
2893.932 Amps MCB TPN C CURVE 10 KA - 1BI01010001010000000000000515BI0100001402
2903.91BUS BARBI01010001010000000000000515BI0100001403
2913.92TPN Aluminium bus bars (having 100% neutral) of minimum of 100 Amps. Capacity with heat shrinkable colored sleeves and i/c DMC/SMC bus bar supports at required intervals complete for cross section, size supports & their spacing etc.The current density of aluminium bus shall be 1 Amp/sq. mm.- 1 Set.BI01010001010000000000000515BI0100001404
2923.93ACDB as described above (NSI)BI01010001010000000000000515BI01000014053Each
2933.94Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)BI01010001010000000000000515BI0100001406
2943.9512 way , Double door (DSR E&M 2.3.3)BI01010001010000000000000515BI010000140724each
2953.96Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.BI01010001010000000000000515BI0100001408
2963.97Single pole (DSR E&M 2.10.1)BI01010001010000000000000515BI0100001409240each
2973.98Single pole and neutral (DSR E&M 2.10.2)BI01010001010000000000000515BI010000141024each
2983.99LT CABLING, WIRING & EARTHINGBI01010001010000000000000515BI0100001411
2994Supplying and fixing of following sizes of steel conduit along with accessories insurface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.BI01010001010000000000000515BI0100001412
3004.01for exhaust fan 20mm (DSR E&M 1.20.1)BI01010001010000000000000515BI01000014132190Metre
3014.02for weighing room 25 mm (DSR E&M 1.20.3)BI01010001010000000000000515BI0100001414510Metre
3024.03Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.BI01010001010000000000000515BI0100001415
3034.04Group C (DSR E&M 1.8.3)BI01010001010000000000000515BI0100001416135point
3044.05Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12)BI01010001010000000000000515BI0100001417645Meter
3054.06Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. (DSR E&M 1.29)BI01010001010000000000000515BI010000141860Each
3064.07Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. (DSR E&M 1.30)BI01010001010000000000000515BI010000141930Each
3074.08Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 2.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (NSI)BI01010001010000000000000515BI010000142010point
3084.09Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independentswitch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,\ and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.BI01010001010000000000000515BI0100001421
3094.1shed led lights (DSR E&M 1.54.3)BI01010001010000000000000515BI010000142236Point
3104.11Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.BI01010001010000000000000515BI0100001423
3114.12Upto 35 sq. mm (DSR E&M 7.5.1)BI01010001010000000000000515BI0100001424980Metre
3124.13Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.BI01010001010000000000000515BI0100001425
3134.14Upto 35 sq. mm (DSR E&M 7.6.1)BI01010001010000000000000515BI0100001426340Metre
3144.15Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.BI01010001010000000000000515BI0100001427
3154.163.5 X 35 sq. mm (DSR E&M 9.2.32)BI01010001010000000000000515BI010000142824Each
3164.17Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.BI01010001010000000000000515BI0100001429
3174.183 x 2.5 sq. mm (DSR E&M 1.17.12)BI01010001010000000000000515BI0100001430780Metre
3184.193 x 1.5 sq. mm (DSR E&M 1.17.3)BI01010001010000000000000515BI0100001431900Metre
3194.2Supplying following sizes of FRLS PVC insulated armured aluminium conductor, 3.5 core cable in the existing surface/ recessed steel/ PVC conduit as required.BI01010001010000000000000515BI0100001432
3204.213.5 x 35 sq.mm (NSI)BI01010001010000000000000515BI0100001433340Metre
3214.22Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.BI01010001010000000000000515BI0100001434
3224.234 X 6 sq. mm + 2 X 6 sq. mm earth wire (DSR E&M 1.7.9)BI01010001010000000000000515BI0100001435360Metre
3234.24Supplying , Brand Power Cables, Solid Aluminum conductor up to 10 sqmm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape/Extruded Innersheathed for Multicore Cables, Unarmoured, extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7098(Part 1) 1988\nBI01010001010000000000000515BI0100001436
3244.253 core 6 sq mm (NSI)BI01010001010000000000000515BI01000014371410meter
3254.264 core 10 sq mm (NSI)BI01010001010000000000000515BI0100001438150meter
3264.27Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 5.2)BI01010001010000000000000515BI010000143912Set
3274.28Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. (DSR E&M 5.12)BI01010001010000000000000515BI0100001440300meter
3284.29Providing, Installing, Testing & Commissioning of 'Silent Type' Diesel Generating Set alongwith having Prime Power Rating of 62.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 volts suitable for 50 Hz. 3 phase system and for 0.85 Load Factor and consisting of the followings: and as per CPWD specifications:-BI01010001010000000000000515BI0100001441
3294.3Diesel Engine:BI01010001010000000000000515BI0100001442
3304.31Diesel engine 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at NTP conditions and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hour ofBI01010001010000000000000515BI0100001443
3314.32Continuous operation. The engine will be fitted complete with all the required accessories. The Engine should be of Ashok Leyland / M&M / Greaves Cotton/ Kirloskar/ Cummins / Caterpillar / Volvo Penta / Perkins/ Mitsubishi make only.BI01010001010000000000000515BI0100001444
3324.33Engine mounted Instrument Panel fitted with and having digital display for following:BI01010001010000000000000515BI0100001445
3334.34Start-stop switch with keyBI01010001010000000000000515BI0100001446
3344.35Water temperature indicationBI01010001010000000000000515BI0100001447
3354.36Lubrication oil pressure indicationBI01010001010000000000000515BI0100001448
3364.37Lubrication oil temperature indicationBI01010001010000000000000515BI0100001449
3374.38Battery charging indicationBI01010001010000000000000515BI0100001450
3384.39RPM indicationBI01010001010000000000000515BI0100001451
3394.4Over speed indicationBI01010001010000000000000515BI0100001452
3404.41Low lubricant Oil trip indicationBI01010001010000000000000515BI0100001453
3414.42Engine Hours indicationBI01010001010000000000000515BI0100001454
3424.43Alternator:BI01010001010000000000000515BI0100001455
3434.44Synchronous alternator rated at 62.5 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at NTP conditions. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class-F/H insulation. The alternator should be of Stamford / Kirloskar / Leroy Somer / Crompton / Mitsubishi / Caterpillar make only.BI01010001010000000000000515BI0100001456
3444.45Base Frame & FoundationBI01010001010000000000000515BI0100001457
3454.46Both the engine and alternator shall be mounted on suitable base frame mode of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.BI01010001010000000000000515BI0100001458
3464.47Fuel Tank :BI01010001010000000000000515BI0100001459
3474.48Daily service fuel tank of suitable capacity / as per OEM fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.BI01010001010000000000000515BI0100001460
3484.49Exhaust System:BI01010001010000000000000515BI0100001461
3494.5Dry exhausts manifold with residential exhaust silencer and Catalytic convertor i/c all supporting structure.BI01010001010000000000000515BI0100001462
3504.51Starting SystemBI01010001010000000000000515BI0100001463
3514.5212V DC starting system comprising of starter motors voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (25 plate 180 AH lead acid type) as reqd. as per specification.BI01010001010000000000000515BI0100001464
3524.53Make of the Lead Acid battery Exide/ Standard / Amar raja only.BI01010001010000000000000515BI0100001465
3534.54Acoustic and weather proof enclosure (outdoor type) with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications to accommodate item (a) to (f) above as per CPCB-II norms, sound proofing done with high quality rock wool further covered with fiber glass sheet & perforated powder coated sheet as reqd.BI01010001010000000000000515BI0100001466
3544.5562.5 KVA at 0.8 pf 415V 50Hz 3-Ø (NSI)BI01010001010000000000000515BI01000014673each
3554.56Supply, assembly, erection, connecting, testing & commissioning of standard 4.0 metre high Post top (above ground) GRP Pole (Pressures as per IS 875 Part-3), with stiffeners, chain, Allen bolt, foundation bolts, pre fabricated plate, template, accessories, nut and washers, factory finish, Base plate. The column shall also be provided with flush door at the bottom with proper strengthening to the cut-out of the door opening, an outdoor IP-66 rated junction/ looping box with Heavy duty 3 phase & Neutral, 20 Amp connector with 6A/10A DP MCB, double earthing arrangements, including all accessories complete as required as per specifications & approved by the Engineer Incharge. (NSI)BI01010001010000000000000515BI010000146884Each
3564.57Supply, Installation, Testing & Commissioning of 2 MP Box camera with 1/3-inch CMOS, Active pixels 1920x1080; 2 MP at 30fps, Sensitivity – (3200K, reflectivity 89%, F1.4, 30IRE) Color 0.6 lx,Mono 0.008 lux ,With IR 0.0 lx, 120dB or better Wide Dynamic Range (WDR) according to IEC 62676p5, Stream 1 and Stream 2 Should be Configurable at 1080p 30 fps, H.265; M- JPEG, Multiple configurable streams in H.264 or H.265 and M-JPEG, White Balance, Day/ Night , Automatic Electronic Shutter (AES); Dynamic Noise Reduction, Video Analytics line crossing, loitering, counter, occupancy counter, object removal should all be included in the camera, Privacy Masking Twelve independent areas, fully programmable, Memory card slot, IR Range upto 60 metres , Automatic Varifocal 3 to 10 mm, ONVIF Profile S; ONVIF Profile G; IP67 & IK10. Housing, Mounting, Lens, IR Illuminator Should be of Same Make / OEM as of Camera Make. (NSI)BI01010001010000000000000515BI010000146936Each
3574.58Supply, Installation, Testing & Commissioning of network recorder to a maximum of 16 IP cameras,The recorders can be installed with a maximum of 2 internal HDDs for videostorage. Option of a single HDD for storage, plus a DVD burner for video export. Max. capacity per HDD: 6 TB. The recorders comes with a built-in PoE+ switch. 4 alarm i/p & 2 relay o/p. Simultaneous 1/4/9/16 channels playback. H.265/H.264/MJPEG supported. iPhone/Android support. Maximum incoming bandwidth of 256 Mbps. Maximum recording bandwidth of 192 Mbps. 1 I/O for audio. 1 VGA & 1 HDMI outputs. CE, UL & FCC certified. (NSI)BI01010001010000000000000515BI01000014703Each
3584.59Supply, Installation, Testing & Commissioning of 32\" LED display having 3 HDMi, 2 USB ports, Full HD, commercial LED of approved make. (NSI)BI01010001010000000000000515BI01000014713Each
3594.6Supply, Installation, Testing & Commissioning of 24 port Giga PoE Switch with SFP Module of approved make. (NSI)BI01010001010000000000000515BI01000014723Each
3604.61Supply, Installation, Testing & Commissioning of 6U Equipment Rack of approved make. (NSI)BI01010001010000000000000515BI01000014733Each
3614.62Supply, Installation, Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. of approved make. (NSI)BI01010001010000000000000515BI01000014741500Per/Mtr
3624.63Supply, Installation, Testing & Commissioning of CAT 6 UTP Cable of approved make. (NSI)BI01010001010000000000000515BI01000014752400Per/Mtr
3634.64Supply and erection of PVC pipe25mm dia ISI marked ( Medium ) recessed in wall / ceiling etc of approved make. (NSI)BI01010001010000000000000515BI01000014762100Per/Mtr
3644.65Three Phase LTCT Meter\n\nThe 3 Phase CT Operated Trivector Meter The meter has advanced data and tamper recording capabilities and is provided with communication ports.with following features:- Class 0.5s as per relevant IS and IEC Standards\n5A current rating\n3 Phase 4 Wire\n4 Quadrant Measurement\nAnti-tamper features\nSelf-diagnostic capability\nMultiple tariff / Time of day feature\nBidirectional Energy recording\nUpto 4 Maximum Demand registers\nLoad Survey (Interval Data) features\nUpto 12 reset backups\nOptical port/RS 232 / RS 485 / IR / IrDA / RF (2.4 GHz/865-867 MHz) (optional) (NSI)BI01010001010000000000000515BI01000014773Job
3654.66CT ( current transformer) 100/5 amps (NSI)BI01010001010000000000000515BI01000014789Job

AI Tender Summary

OUR REF NO 23470942
AUTHORITY Government Departments
TENDER VALUE 17.84 Crore
LAST DATE 11-02-2020
Authority
Authority Name Chandigarh Smart City Limited
Work Description Construction Of 3 Material Recovery Cum Transfer Stations Under Chandigarh Smart City
Basic Detail
Tender No CSCL_2019_MRF_Civil_2
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 03 Feb 2020
Submission Date 11 Feb 2020
Open Date 11 Feb 2020
Finance
Tender Value 17.84 Crore
Tender Fee 11800
EMD 27.85 Lakhs
Exemption Not Available
Document List
MRFCivil.pdf
BOQ_66708.xls
Tendernotice_1.pdf
Drawings.pdf
D2E9A4CE-B16E-4E7F-9222-7A30968FF715.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Feb 03, 2020
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 11, 2020
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 11, 2020

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

MRFCivil.pdf

xls

BOQ_66708.xls

pdf

Tendernotice_1.pdf

pdf

Drawings.pdf

html

D2E9A4CE-B16E-4E7F-9222-7A30968FF715.html