Provision Of Air Conditioner Points Smart Meters In Offrs Accn In Hs Enclave , Wall Mounted Fans And Exhaust Fans At Corps Zonal Wksp , Special Repairs To Security Light Replacement Of Ber Fire Fighting Pump Set And Other Allied Work Under Ge Naran, GE NARANGI-Assam

Military Engineer Services-MES has published Provision Of Air Conditioner Points Smart Meters In Offrs Accn In Hs Enclave , Wall Mounted Fans And Exhaust Fans At Corps Zonal Wksp , Special Repairs To Security Light Replacement Of Ber Fire Fighting Pump Set And Other Allied Work Under Ge Naran. Submission Date for this Tender is 27-02-2020. Electrification Work Tenders in GE NARANGI Assam. Bidders can get complete Tender details and download the document.




Tender Notice

23469237
Corrigendum : Provision Of Air Conditioner Points Smart Meters In Offrs Accn In Hs Enclave , Wall Mounted Fans And Exhaust Fans At Corps Zonal Wksp , Special Repairs To Security Light Replacement Of Ber Fire Fighting Pump Set And Other Allied Work Under Ge Naran
Open Tender
Indian
Assam
GE NARANGI
27-02-2020

Tender Details

Provision Of Air Conditioner Points Smart Meters In Offrs Accn In Hs Enclave , Wall Mounted Fans And Exhaust Fans At Corps Zonal Wksp , Special Repairs To Security Light Replacement Of Ber Fire Fighting Pump Set And Other Allied Work Under Ge Narangi .

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Feb-2020 Date Amendment No 1 Date 27-02-2020

Key Value

Document Fees
INR 500 /-
EMD
INR 91000.0 /-
Tender Value
INR 45.50 Lakhs /-

BOQ Items

Name of Work : Provision of AC points & smart meters in offrs accn in HS Enclave, wall mounted fans and exhaust fans at corps Zonal WKSP, special repairs to security light & replacement of BER fire fighting pump set and other allied work under GE Narangi.
Sl. No. Item Description Item Code / Make Quantity Units
1 1 Excavation in trenches not exc 1.5 mtr wide & not exc 1.5 mtr in depth: for foundation etc or for manholes, laying of pipe, cables etc in soft / loose soil and getting out complete all as specified and as directed.\n 156 Cum
2 2 Returning, filling in, soil including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and as directed. 110 Cum
3 3 Removing excavated soil to distance not exc 50 m & depositing where directed at a level not exc 1.5 m above starting point complete all as specified and as directed. 46 Cum
4 4 Taking out 150 mm bore CI water main with fittings from trenches complete all as specified and as directed. 50 Rm
5 5 Supply, laying and testing ductile iron pressure pipe of 150 mm dia, ISI marked with screwed double flange-end, class K-9, PN-10, confirming to IS-8329 / 2000 blast furnace slag cement with portland cement properties suitable for jointing with inside cement mortar lining, external black bitumen coating laid in trenches including gasket, nuts, bolts, washers etc complete all as specified and as directed. \n 50 Rm
6 6 M & L for ducite iron fittings for spigot and socket pipes of size 150 mm bore dia such as bends (any type,radius and angle) tapers any type (straight, bend, increasing,decreasing or double socket etc), Tee pieces, single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs complete all as specified and as directed. 155 Kg
7 7 S & F in repair sluice valve (heavy duty) with SS spindle conforming to IS 14846 both end flanged class PN 1.6 of size 150 mm dia including necessary nuts, bolts washers and gasket complete all as specified and as directed. 4 Each
8 8 S & F in repair, non return valve including necessary fixing accessories for 150 mm dia pipe complete all as specified and as directed. 2 Each
9 9 S & F in repair, foot valve (stainer) including necessary fixing accessories for 150 mm dia pipe complete all as specified and as directed. 1 Each
10 10 S & F fire pump electrically driven 75 HP horizontal end Suction, centrifugal type confirming to IS- 12469 :1988 with CI Casing, bronze impeller and Stainless steel shaft mounted on heavy duty bearings Suitable for continuous operation with 'range of operation' 0 % to 150 % of rated capacity for 440 V, 3 Phase. 50 Hz 90m Head, 2850 LPM discharge complete all as specified and as directed. 1 Each
11 11 S & F in repair 3 phase, fully automatic Star Delta starter in sheet enclosure type 415 Volt, 50 Hz relay range 45-75 A, AC 3, suitable for 75 HP pumpset complete all as specified and as direted. \nMake L&T , CAT No. SS90913 or equivqlent in BCH/Havells. 1 Each
12 12 S & F in repairs, PVC insulated multistrand 70 Sqmm single core (FR) cable with copper conductor 1100 Volt garde conforming to IS-694/1990 complete all as specified and as directed. 40 Rm
13 13 M & L for point wiring with 2.5 Sqmm single core, PVC insulated and unsheathed FRLS grade cable 1100V grade IS 694 marked with multistranded copper conductor and earth continuity wire 2.5 Sqmm cable (including connecting to earth dolly) drawn in and including conduit, concealed / surface on walls / ceiling complete for 6 pin 15 Amps switch socket comination outlet on independent baord all as specified and as directed. 18 per point
14 14 S & F switch socket combination 3 pin 5A / 16A, 5 in 1, flush type, single pole complete all as specified and as directed. 18 Each
15 15 S & F ceiling rose , 3 Phase / PVC / polycarbonate isolated body complete all as specified and as directed. 18 Each
16 16 S & F pre lubricated, double ball bearing, vibration free, heavy duty exhaust fan of 600 mm sweep, single phase, 230V, 900 RPM conforming to IS 2312-1967 metallic frame with blades and louvers fixing complete with nut bolts including cutting of holes on window of required size & making good disturbed surface complete all as specified and as directed. 8 Each
17 17 S & F pre lubricated, double ball bearing, vibration free heavy duty wall mounted fan of 600 mm sweep, single phase, 230V, 1440 RPM conforming to IS 2312 - 1967 metallic frame with blades and louvers fixing complete with nut bolts including all accessories and fixing on wall including cutting of holes of required size and making good disturbed surface complete all as specified and as directed.\n 10 Each
18 18 S & F MCBs, SP 6 to 32 Amps, 10 KA , IS / IEC 60898 - 12002 in existing DBs, complete all as specified and as directed. Make:- ABB/Legrand/Havells/ Schnider 6 Each
19 19 S & F industrial socket with MCB SP 32A, 'C' Curve complete all as specified and as directed.\nMake :- Havells / Legrand / L & T / Schnider 120 Each
20 20 S & F customer interface unit (Home display unit) complete all as specified and as directed. 40 Each
21 21 M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4.00 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on complete all as specified and as directed. 1625 Rm
22 22 Cutting chases in wall / concrete for concealed conduit wiring and making good disturbed surface, for cutting not exc 10 cm girth complete all as specified and as directed. 1625 Rm
23 23 M & L for tamper proof, prepaid energy smart meter 3 phase, 4 wire, 3 x 240V, 10 to 60A, class 1.0, 50 Hz, with LCD display, Kwh LED, encrypted STS based token system as per IS-15884, Complying to IS-51 housed in engineering plastic complete all as specified and as directed.\nMake : L&T / HPL / SCHNEIDER 40 Each
24 24 Taking down old / Repair in situ to high mast light fitting mounted on 12 to 15 mtr height structure of qty 4 to 6 light fitting ,disconneting electrically ,testing of all components to ascertain defective part of the fitting and testing the conductivity of electric cable of internal wiring of fittings and taking down on replacement if not repairable , complete all as specified and as directed. \n(The replacement of flood / high mast light should be measured and paid separately). 6 Each job
25 25 S & F LED Street light luminaries, 70 Watts WSPD epoxy powder coated, pressure die cast aluminum housing with wheatherproof gasket for LED's and control gear compartments, pressure die cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, LED Specification: CREE LED / Equivalent, Colour temp - 6500 K +/- 300 K Lens, IP-66, Lumen efficiency >100 lm/w, surge protection 4kv internal (Built-in) with twin core conductor complete all as specified and as directed. Including taking down old sodium vapour / tube light fitting & testing on completion. \nMake: Havells CAT No. ENDURAPEARLPLUS70WLED757SASYTOPC or equivalent of Philips / Wipro / CG.\nNote:- Driver and luminaries of LED street light should be same as make approved. 98 Each
26 26 M & L for replacement of street light bracket, made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 2.0 mtrs complete all as specified and as directed. 50 Each
27 27 S & F in repairs steel tubular swaged pole, complete with MS base plate welded to pole, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 M long) confirm to IS-2713 (part 1 to 3) 1980 complete including a coat of painting (inside and outside) including demolition of existing coping, foundation concrete complete all as specified and as directed. 9 Each
28 28 M & L for PCC, Type D2, 1: 3:6, using 40 mm graded stone aggregate in foundations of poles, fillings and mass concrete complete all as specified and as directed. 4 Cum
29 29 M & L for PCC, Type C -1, 1:2:4, using 20 mm graded stone aggregate as in coping of poles and the like including formwork, weathering, slightly rounded or chamfered angle and throating complete all as specified and as directed. 1 Cum
30 30 M & L in repairs, cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core laid in trenches / fixed on poles etc, complete all as specified and as directed.\nNote :- Excavation and earth work will be measured & paid seperately. 250 Rm
31 31 M & L in repairs, cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 2 core laid in trenches / fixed on poles etc, complete all as specified and as directed. \nNote :- Excavation and earth work will be measured & paid seperately. 150 Rm
32 32 M & L in repairs, cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16.0 sq mm 4 core laid in trenches / fixed on poles etc, complete all as specified and as directed. \nNote :- Excavation and earth work will be measured & paid seperately. 150 Rm
33 33 M & L in repairs, cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70.0 sq mm 3.5 core laid in trenches / fixed on poles etc, complete all as specified and as directed. \nNote :- Excavation and earth work will be measured & paid seperately. 150 Rm
34 34 M & L for fine dry river sand for cushioning to UG cable, including spreading levelling and hand punning etc complete all as specified and as directed.\nNote :- Punned thickness only will be measured & paid. 45 Cum
35 35 M & L for sub class ‘B’ bricks, old size for cable protection laid flat in trenches over the cable with length of brick perpendicular to the direction of cable and width of brick along the direction of cable complete all as specified and as directed. 5 Per 1000
36 36 S & F in repairs, transparent street light junction box of size 155 mm x 2100 mm x 92 mm made of high quality polycarbonate IP65 (Dust and power jet proof according to IEC 60529), shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK08) totally insulated (class II) made of halogen and silica free recyclabe material UV resistant having high grade gasket made of polyurethane with Al-bus bar 25 mm x 5 mm - 04 strip, one no MCB DP 6 Amps with locking arrangement and M40 size cable gland and one M32 size gland suitable upto 50 sqmm cable complete all as specified and as directed.\nMake : HENSEL cat no-KF1616G or equivalent. 64 Each
37 37 S & F GI tube 40 mm bore, light grade with all fittings fixed complete to wall / ceiling / pole or laid in trenches on floor for protection of electric cable includind cutting existing floor complete all as specified and as directed. 25 Rm
38 38 S & F in repairs, replacement of street light timer switch (Astro mini) 110-240 VAC 1 Phase-2W, 1 C/O , Base / DIN complete all as specified as directed.\nMake -L&T Cat no-T2DDT7 or equivalent in Legrand / Schneider 4 Each
39 39 S & F in repairs, replacement of street light contactor 50A complete all as specified as directed.\nMake -L&T Cat no-CS94572 or equivalent in C & S Electric Ltd / ABB / BCH / Siemens / Schnieder. 4 Each
40 40 Earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6.3 mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt fliing in alternate layers etc and connected to and including galvanised earth lead wire 4 mm upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 20 mm dia GI pipe connected to main control board and GI pipe medium grade 40 mm bore for watering and including funnel, wire mesh, charcoal salt etc RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C / C and PCC chamber pit with PCC (1:3:6) type C1 (using 20 mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after complete all as specified and directed and shown on plate No 3 of SSR Part-I 2009 8 Each Job